Inquiry Now
BH-0.66 60I low-voltage current transformer

BH-0.66 60I Low-Voltage Current Transformer 200/5A–1500/5A

BH-0.66 60I closed-core low-voltage current transformer with eleven verified current ratios from 200/5A to 1500/5A and row-specific burden and accuracy-class options.

200/5A-1500/5A
Eleven verified ratios

1.0 to 0.2S
Classes where listed

2.5 / 5 / 10 VA
Burden by exact row

1 core
Documented core count

Product Information

Product Overview

The BH-0.66 60I is a closed-core low-voltage current-transformer family. Current ratio, accuracy class and rated burden remain tied to the exact row in the verified configuration matrix.

Key Features

  • Eleven verified current-ratio configurations
  • 5A secondary designation across listed ratios
  • Row-specific accuracy classes
  • Row-specific 2.5VA, 5VA or 10VA burden
  • Closed-core one-core construction

Available Models / Configurations

Use the exact ratio row and confirm the required accuracy class and rated burden; blank cells are not implied options.

Current RatioClass 1.0Class 0.5Class 0.5SClass 0.2Class 0.2SCore Count
200/5A2.5 VA2.5 VA1
250/5A2.5 VA2.5 VA1
300/5A5 VA5 VA5 VA5 VA5 VA1
400/5A5 VA5 VA5 VA5 VA5 VA1
500/5A5 VA5 VA5 VA5 VA5 VA1
600/5A5 VA5 VA5 VA5 VA5 VA1
750/5A10 VA10 VA10 VA10 VA10 VA1
800/5A10 VA10 VA10 VA10 VA10 VA1
1000/5A10 VA10 VA10 VA10 VA10 VA1
1200/5A10 VA10 VA10 VA10 VA10 VA1
1500/5A10 VA10 VA10 VA10 VA10 VA1

Technical Specifications

SpecificationVerified Value
Product TypeClosed Low-Voltage Current Transformer
ModelBH-0.66 60I
Available Current Ratios200/5A / 250/5A / 300/5A / 400/5A / 500/5A / 600/5A / 750/5A / 800/5A / 1000/5A / 1200/5A / 1500/5A
Accuracy Classes1.0 / 0.5 / 0.5S / 0.2 / 0.2S where listed in the exact row
Rated Burden2.5 VA / 5 VA / 10 VA according to ratio and class
Core Count1

Applications

Industrial electrical control cabinet application context

Low-voltage distribution monitoring

Closed-core current measurement after the required ratio, conductor fit and burden are confirmed.

Switchgear and panel metering

Current-transformer input for compatible industrial meters and monitoring equipment.

Industrial energy monitoring

Ratio-specific current measurement in compatible electrical distribution systems.

Information to Confirm for Selection

  • Required current ratio from 200/5A to 1500/5A
  • Required accuracy class from the exact row
  • Required rated burden from the exact row
  • Conductor fit and installation arrangement
  • Quantity, application and destination country

FAQ

Which current ratios are available?

Eleven ratios are listed from 200/5A to 1500/5A.

Are all accuracy classes available for every ratio?

No. Use the exact configuration table; blank class cells are not presented as available options.

How is rated burden selected?

Rated burden is tied to the exact current-ratio and accuracy-class row: 2.5VA, 5VA or 10VA as listed.

Request a Quote

Provide the required BH-0.66 60I ratio, accuracy class, rated burden, quantity and application.

Request Product Information & Pricing

Send model numbers, ratings, quantities and destination details. We will confirm availability before preparing a quotation.