{"id":1909,"date":"2026-10-01T00:18:51","date_gmt":"2026-10-01T00:18:51","guid":{"rendered":"https:\/\/ritoks.com\/?p=1909"},"modified":"2026-10-06T01:09:08","modified_gmt":"2026-10-06T01:09:08","slug":"scr-module-heatsink-selection-thermal-evidence","status":"publish","type":"post","link":"https:\/\/ritoks.com\/da\/scr-module-heatsink-selection-thermal-evidence\/","title":{"rendered":"Valg af SCR-modul og k\u00f8leplade: Der kr\u00e6ves termisk dokumentation"},"content":{"rendered":"<p class=\"wp-block-paragraph\">Et SCR-moduls nominelle str\u00f8mstyrke er ikke afg\u00f8rende for st\u00f8rrelsen p\u00e5 k\u00f8lepladen. Valget af k\u00f8leplade afh\u00e6nger af tabene i den faktiske driftscyklus, den tilladte krydstemperatur, varmeoverf\u00f8ringsvejene mellem krydset og kabinettet samt gr\u00e6nsefladerne, k\u00f8leforholdene og den m\u00e5de, modulet er monteret p\u00e5. Et tilbud p\u00e5 et modul og en tilsyneladende stor ekstruderet aluminiumsprofil udg\u00f8r ikke et f\u00e6rdigt termisk design.<\/p>\n<p class=\"wp-block-paragraph\">Denne vejledning beskriver, hvilke oplysninger der skal indhentes, inden der v\u00e6lges en k\u00f8leplade til et thyristormodul. Den fokuserer p\u00e5 indgangsdata, beregningsrammer og verifikation, ikke p\u00e5 at fastl\u00e6gge en termisk modstandsv\u00e6rdi for et ukendt kredsl\u00f8b. Den n\u00f8jagtige SCR-bestillingskode og anvendelsens b\u00f8lgeformer er fortsat afg\u00f8rende.<\/p>\n<h2 class=\"wp-block-heading\">Start med applikationens b\u00f8lgeform<\/h2>\n<p class=\"wp-block-paragraph\">Not\u00e9r kredsl\u00f8bets opbygning og den enkelte tyristorens funktion: styret ensretning, vekselstr\u00f8msregulering, bl\u00f8d opstart eller en anden funktion. Not\u00e9r, om modulet indeholder en enkelt enhed, en dobbeltkonfiguration eller en anden intern forbindelse. Den samme str\u00f8mv\u00e6rdi angivet p\u00e5 typeskiltet kan svare til meget forskellige ledningstider, impulsformer og varmeudvikling i forskellige kredsl\u00f8b.<\/p>\n<p class=\"wp-block-paragraph\">Provide the RMS and average current information relevant to the manufacturer&#8217;s loss model, together with conduction angle, repetition, duty cycle and overload events. Include the current waveform or a validated simulation when possible. Do not take a sine-wave datasheet test point and treat it as a universal loss figure for a chopped or highly pulsed application.<\/p>\n<p class=\"wp-block-paragraph\">Identificer den v\u00e6rste vedvarende belastning og de v\u00e6sentlige transiente tilstande hver for sig. Opstart, startstr\u00f8m og kortvarig overbelastning kan kr\u00e6ve en gennemgang af den termiske impedans under transiente tilstande, mens kontinuerlig drift kr\u00e6ver en analyse af station\u00e6r tilstand. En k\u00f8leplades termiske masse er ikke grund nok til at se bort fra gentagne impulser; gentagelser kan forhindre systemet i at vende tilbage til sin oprindelige temperatur.<\/p>\n<h2 class=\"wp-block-heading\">Beregne tab ud fra oplysninger fra den eksakte model<\/h2>\n<p class=\"wp-block-paragraph\">Request the exact model&#8217;s on-state voltage or loss parameters and the manufacturer&#8217;s recommended calculation method. Where the module has multiple devices, track loss per conducting element and the total heat injected into the shared baseplate. Power loss is an input to thermal analysis; it is not the same as the output power or load rating of the equipment.<\/p>\n<p class=\"wp-block-paragraph\">Kontroller, om databladet angiver kurver ved bestemte krydstemperaturer og str\u00f8mforhold. Hvis en leverand\u00f8r angiver en enkelt \u201ctypisk\u201d v\u00e6rdi, skal du sp\u00f8rge om forholdene og om der foreligger en maksimums- eller konstruktionsv\u00e6rdi. Angiv usikkerheden i stedet for at oplyse en pr\u00e6cis k\u00f8leribbetemperatur baseret p\u00e5 ikke-verificerede typiske data.<\/p>\n<p class=\"wp-block-paragraph\">For en ensretter eller et fasestyringssystem skal b\u00e5de ledningsvejen og de enkelte komponenters andel af str\u00f8mmen over tid pr\u00e6ciseres. Et modul med to SCR\u2019er fordeler muligvis ikke tabene ligeligt, hvis styreskemaet eller kredsl\u00f8bets drift er asymmetrisk. Den termiske model b\u00f8r afspejle de faktiske ledende komponenter og, hvis n\u00f8dvendigt, afstanden mellem flere varmekilder p\u00e5 \u00e9n k\u00f8leplade.<\/p>\n<figure data-spectra-id=\"spectra-65d306ae-84b6-4307-a830-6f2569c4befa\" class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" height=\"1050\" width=\"1400\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/scr-module-heatsink-selection-thermal-evidence-body-01.webp\" alt=\"SCR\u2019ens termiske modstandsvej fra krydspunktet til kabinettet, gr\u00e6nsefladen, k\u00f8lepladen og det omgivende milj\u00f8\" class=\"wp-image-1907\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/scr-module-heatsink-selection-thermal-evidence-body-01.webp 1400w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/scr-module-heatsink-selection-thermal-evidence-body-01-300x225.webp 300w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/scr-module-heatsink-selection-thermal-evidence-body-01-1024x768.webp 1024w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/scr-module-heatsink-selection-thermal-evidence-body-01-768x576.webp 768w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/scr-module-heatsink-selection-thermal-evidence-body-01-600x450.webp 600w\" sizes=\"auto, (max-width: 1400px) 100vw, 1400px\" \/><figcaption class=\"wp-element-caption\">Spor SCR-varmen fra krydset gennem gr\u00e6nsefladen til den omgivende luft.<\/figcaption><\/figure>\n<h2 class=\"wp-block-heading\">L\u00e6s den fulde termiske vej<\/h2>\n<p class=\"wp-block-paragraph\">A simplified steady-state path runs from junction to case, case through thermal interface material to heatsink, and heatsink to ambient. Each stage contributes temperature rise under the relevant heat flow. Infineon&#8217;s module mounting guidance emphasizes that thermal interface material, application and geometry affect conduction between module and sink. No catalogue heatsink number can compensate for a poorly controlled contact interface.<\/p>\n<p class=\"wp-block-paragraph\">Obtain the exact module&#8217;s thermal-resistance or transient-impedance data and understand the measurement reference points. \u201cJunction-to-case\u201d is not automatically comparable across different internal configurations or test conventions. The sink supplier&#8217;s thermal-resistance figure also has conditions: airflow, orientation, base area and a particular heat-source arrangement may be assumed.<\/p>\n<p class=\"wp-block-paragraph\">Check where the equipment&#8217;s ambient reference is measured. Air near an SCR bank, inside a crowded cabinet, may be hotter than room air. A fan&#8217;s free-air rating is not the airflow through the sink fins once filters, guards and nearby components are installed. In a design review, use the relevant local inlet-air condition rather than the most favorable laboratory ambient.<\/p>\n<h2 class=\"wp-block-heading\">Angiv gr\u00e6nsefladen og monteringsvejledningen<\/h2>\n<p class=\"wp-block-paragraph\">Thermal compound, pad or factory-applied interface material is part of the designed path. Record which interface is allowed for the exact module, the required surface flatness and cleanliness, and the manufacturer&#8217;s placement and fastening sequence. A change of compound or mounting pressure can change contact resistance even if the electrical module and sink are unchanged.<\/p>\n<p class=\"wp-block-paragraph\">Ask for specified mounting torque, fastener pattern, electrical clearances and any re-tightening or burn-in instruction. These details should come from the current module installation manual, not from a generic torque chart. Infineon&#8217;s power-module documentation explicitly treats mounting as a thermal-performance and reliability issue; RITOKS products require their own exact-model instructions before assembly release.<\/p>\n<p class=\"wp-block-paragraph\">Overvej, om flere moduler deler en k\u00f8leplade. Mekanisk interferens, varmefordeling, elektrisk isolering og blokering af luftstr\u00f8mmen kan p\u00e5virke ydeevnen. Hvis k\u00f8lepladen er elektrisk forbundet med en del af kredsl\u00f8bet via et modulunderlag, skal konstruktionen tage h\u00f8jde for de kr\u00e6vede isolerings- og sikkerhedsafstande i stedet for at betragte k\u00f8lepladen som harml\u00f8st metalv\u00e6rk.<\/p>\n<h2 class=\"wp-block-heading\">Sammenlign naturlig og tvungen konvektion p\u00e5 den monterede geometri<\/h2>\n<p class=\"wp-block-paragraph\">Naturlig konvektion afh\u00e6nger i h\u00f8j grad af ribbenes retning, afstanden mellem dem og uhindret opstigende luft. Tvungen konvektion afh\u00e6nger af den tilf\u00f8rte luftstr\u00f8m gennem varmeveksleren, ikke kun af ventilatorens friluftstr\u00f8m. Valget har ogs\u00e5 indflydelse p\u00e5 kravene til st\u00f8j, st\u00f8v, filtre og vedligeholdelse. Det skal afg\u00f8res, om kabinettet kan klare den tilsigtede luftstr\u00f8m gennem hele sin levetid.<\/p>\n<p class=\"wp-block-paragraph\">Request a sink performance curve or tested thermal resistance under conditions close to the installed arrangement. If the data uses another heat-source footprint, ask the sink supplier how to correct or test it. Infineon&#8217;s heatsink-selection guidance stresses that optimization is iterative and that published thermal resistance is conditional on how it was measured.<\/p>\n<p class=\"wp-block-paragraph\">En k\u00f8lemargen b\u00f8r begrundes ud fra den beregnede usikkerhed, ekstreme omgivelsesforhold og antagelser om vedligeholdelse. Hvis man dimensionerer en k\u00f8ler for stort uden at kontrollere gr\u00e6nsefladen og luftstr\u00f8mmen, kan man overse den egentlige flaskehals. Omvendt kan en lille k\u00f8ler kun anses for at v\u00e6re tilstr\u00e6kkelig til intermitterende drift, hvis den transiente varmemodel og gentagelsesfrekvensen er dokumenteret.<\/p>\n<h2 class=\"wp-block-heading\">Brug en tabel over termiske beviser, ikke en sammenligning, der udelukkende er baseret p\u00e5 str\u00f8m<\/h2>\n<figure class=\"wp-block-table\"><table><thead><tr><th>Bevismateriale<\/th><th>Projektmateriale<\/th><th>Leverand\u00f8ren bekr\u00e6fter<\/th><\/tr><\/thead><tbody><tr><td>Elektrisk drift<\/td><td>B\u00f8lgeform, ledningsm\u00f8nster, overbelastning<\/td><td>Pr\u00e6cis metode til registrering af tabte enheder<\/td><\/tr><tr><td>Krydsgr\u00e6nse<\/td><td>Design af driftsomr\u00e5de<\/td><td>Temperaturgr\u00e6nse for den n\u00f8jagtige model<\/td><\/tr><tr><td>Intern varmebane<\/td><td>Placering af enheden p\u00e5 vasken<\/td><td>Data om forbindelser til kabinettet<\/td><\/tr><tr><td>Gr\u00e6nseflade<\/td><td>Samleproces<\/td><td>Tilladte TIM-typer og monteringsvejledning<\/td><\/tr><tr><td>Vejen fra vand til luft<\/td><td>Omgivelses- og luftstr\u00f8msforhold<\/td><td>Vaskens ydeevne under relevante betingelser<\/td><\/tr><\/tbody><\/table><\/figure>\n<p class=\"wp-block-paragraph\">S\u00f8rg for, at alle indtastede data er knyttet til en tegningsrevision og en ordrekode. En \u00e6ndring i SCR-topologi, modulpakke, luftvej eller styreb\u00f8lgeform kan g\u00f8re den oprindelige varmeberegning ugyldig. Indk\u00f8bsafdelingen b\u00f8r ikke erstatte moduler med \u201ctilsvarende\u201d moduler alene p\u00e5 baggrund af str\u00f8m- og sp\u00e6ndingsm\u00e6rkater, hvis den termiske vej er anderledes.<\/p>\n<figure data-spectra-id=\"spectra-36748c69-26cd-478d-9a6a-bf5959ed9a15\" class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" height=\"1050\" width=\"1400\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/scr-module-heatsink-selection-thermal-evidence-body-02.webp\" alt=\"Tjekliste for SCR-k\u00f8leplade: Sammenligning af den elektriske belastning med dokumentationen for modul, gr\u00e6nseflade og k\u00f8leplade\" class=\"wp-image-1908\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/scr-module-heatsink-selection-thermal-evidence-body-02.webp 1400w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/scr-module-heatsink-selection-thermal-evidence-body-02-300x225.webp 300w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/scr-module-heatsink-selection-thermal-evidence-body-02-1024x768.webp 1024w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/scr-module-heatsink-selection-thermal-evidence-body-02-768x576.webp 768w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/scr-module-heatsink-selection-thermal-evidence-body-02-600x450.webp 600w\" sizes=\"auto, (max-width: 1400px) 100vw, 1400px\" \/><figcaption class=\"wp-element-caption\">Registrer de dokumenter, der er n\u00f8dvendige for at afklare hver enkelt antagelse vedr\u00f8rende termisk design.<\/figcaption><\/figure>\n<h2 class=\"wp-block-heading\">Bekr\u00e6ft ved hj\u00e6lp af m\u00e5linger ved en repr\u00e6sentativ belastning<\/h2>\n<p class=\"wp-block-paragraph\">Calculation screens candidates; installed testing verifies the model. Define the operating cycle, enclosure condition and measurement points before the test. A case or sink temperature reading is meaningful only when its location matches the calculation reference. If direct junction measurement is unavailable, use the manufacturer&#8217;s approved method to infer junction temperature from measured values and losses.<\/p>\n<p class=\"wp-block-paragraph\">Kontroller en vedvarende tilstand med h\u00f8j belastning samt eventuelle vigtige forbig\u00e5ende tilstande eller tilstande med gentagne cyklusser. Dokumenter bl\u00e6serhastighed, filtertilstand, omgivelsestemperatur samt varmekilder i n\u00e6rheden. Hvis den m\u00e5lte temperatur afviger fra forventningen, skal du unders\u00f8ge antagelserne om tab, gr\u00e6nsefladens anvendelse, luftstr\u00f8mmen og sensorens placering. Undg\u00e5 at skjule en afvigelse ved at justere en enkelt antaget modstand uden dokumentation.<\/p>\n<p class=\"wp-block-paragraph\">Medtag kontrolforanstaltninger for produktionsmontering. En prototype, der er omhyggeligt samlet af en ingeni\u00f8r, kan fungere anderledes end en serieproduktion, hvis p\u00e5f\u00f8ringen af lim eller r\u00e6kkef\u00f8lgen for fastg\u00f8relsen varierer. Angiv inspektionspunkter, der er praktisk gennemf\u00f8rlige p\u00e5 produktionsgulvet, og gem derefter den verificerede monteringsproces sammen med produktdokumentationen.<\/p>\n<h2 class=\"wp-block-heading\">Hvad skal man vedl\u00e6gge ved en foresp\u00f8rgsel om et SCR-modul<\/h2>\n<p class=\"wp-block-paragraph\">Send oplysninger om kredsl\u00f8bets topologi, b\u00f8lgeform og arbejdscyklus, den kr\u00e6vede sp\u00e6rresp\u00e6nding, forventede overbelastningsh\u00e6ndelser, den tilg\u00e6ngelige k\u00f8leplads, omgivelses- og luftstr\u00f8msforhold, monteringsopstilling samt den kr\u00e6vede dokumentation. Anmod om n\u00f8jagtige data vedr\u00f8rende modulets tab og termiske egenskaber, mekanisk tegning, vejledning om gr\u00e6nseflader samt installationsvejledning. Den <a href=\"https:\/\/ritoks.com\/da\/product-category\/power-semiconductor-modules\/scr-thyristor-modules\/\">Kategori: SCR-\/thyristormoduler<\/a> hj\u00e6lper med at identificere produktfamilier; valget afh\u00e6nger stadig af den enkelte model.<\/p>\n<p class=\"wp-block-paragraph\">For at f\u00e5 et overblik over indk\u00f8bssituationen kan du l\u00e6se <a href=\"https:\/\/ritoks.com\/da\/products\/mta-dual-scr-thyristor-module-25a-1000a\/\">MTA-serien med dobbelt SCR-system<\/a>, <a href=\"https:\/\/ritoks.com\/da\/products\/mtc-scr-thyristor-module-55a-200a\/\">MTC SCR-serien<\/a> eller <a href=\"https:\/\/ritoks.com\/da\/products\/mtc-high-current-scr-module-250a-1500a\/\">MTC-serien til h\u00f8jstr\u00f8m<\/a> hvis det er relevant. Deres sider kan ikke erstatte de aktuelle tabskurver eller monteringsvejledninger. Sp\u00f8rg <a href=\"https:\/\/ritoks.com\/da\/contact-us\/\">RITOKS<\/a> for det p\u00e5g\u00e6ldende dokuments\u00e6t, inden en ordrekode fastfryses.<\/p>\n<h2 class=\"wp-block-heading\">Ofte stillede sp\u00f8rgsm\u00e5l<\/h2>\n<h3 class=\"wp-block-heading\">Kan man v\u00e6lge en k\u00f8leplade ud fra SCR\u2019ens str\u00f8mkapacitet?<\/h3>\n<p class=\"wp-block-paragraph\">Nej. Den angivne str\u00f8mv\u00e6rdi er kun \u00e9n af enhedens specifikationer. Det faktiske str\u00f8mforl\u00f8b, tab, omgivelsestemperatur, gr\u00e6nseflade og k\u00f8lekonfiguration er afg\u00f8rende for de termiske krav.<\/p>\n<h3 class=\"wp-block-heading\">Garanterer tilf\u00f8jelsen af en ventilator en st\u00f8rre fortjeneste?<\/h3>\n<p class=\"wp-block-paragraph\">Dette g\u00e6lder kun, hvis der er tilstr\u00e6kkelig luftstr\u00f8m til de p\u00e5g\u00e6ldende ribbeflader under de faktiske installationsforhold. Kontroller filtre, eventuelle hindringer, ventilatorens driftstilstand og data om k\u00f8leelementets ydeevne.<\/p>\n<h3 class=\"wp-block-heading\">Hvad er beviset for endelig godkendelse?<\/h3>\n<p class=\"wp-block-paragraph\">En model-specifik beregning, en kontrolleret monteringsmetode og en repr\u00e6sentativ temperaturtest udg\u00f8r tilsammen et velbegrundet beslutningsgrundlag. Intet enkelt dokument kan bevise alle tre dele.<\/p>\n<h2 class=\"wp-block-heading\">Konklusion<\/h2>\n<p class=\"wp-block-paragraph\">Definer f\u00f8rst det elektriske tab, spor derefter den komplette varmevej, og kontroller den monterede enhed. Et par best\u00e5ende af et SCR-modul og en k\u00f8leplade er et systemvalg. S\u00f8rg for, at uafklarede modelspecifikke termiske data fremg\u00e5r tydeligt af tilbudsanmodningen i stedet for at udfylde den med antagelser fra et katalog. Den endelige tegning skal angive det valgte modul, k\u00f8lepladen, gr\u00e6nsefladematerialet, luftstr\u00f8mningsretningen og de validerede testbetingelser som \u00e9n samlet enhed.<\/p>\n<h2 class=\"wp-block-heading\">Referencer<\/h2>\n<ul class=\"wp-block-list\"><li><a href=\"https:\/\/www.infineon.com\/dgdl\/Infineon-Use_and_Installation_Manual_34mm_and_50mm_Solder_Bond_Modules-ApplicationNotes-v01_03-EN.pdf?fileId=5546d462576f3475015775517f2622cd\" target=\"_blank\" rel=\"noopener\">Infineon, 34 mm and 50 mm Solder Bond Modules \u2014 Use and Installation Manual (AN2018-07)<\/a>.<\/li><li><a href=\"https:\/\/www.infineon.com\/dgdl\/Infineon-CIPOS_Maxi_IPM_IM12BxxxC1_series-ApplicationNotes-v01_00-EN.pdf?fileId=8ac78c8c90530b3a01908868b8ec22fb\" target=\"_blank\" rel=\"noopener\">Infineon: Vejledning i udformning af termiske systemer og valg af k\u00f8leplader<\/a> (generelle principper for k\u00f8lelegemer; ikke en RITOKS SCR-specifikation).<\/li><li><a href=\"https:\/\/www.semikron-danfoss.com\/service-support\/application-support\/application-manual\" target=\"_blank\" rel=\"noopener\">Semikron Danfoss, Anvendelsesvejledning til effekt-halvledere<\/a>.<\/li><\/ul>","protected":false},"excerpt":{"rendered":"<p>Select an SCR heatsink from application losses, complete thermal path, installed airflow and model-specific mounting evidence, not current rating alone.<\/p>","protected":false},"author":1,"featured_media":1906,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ritoks_resource_detail_renderer":"viox","ritoks_resource_product_cat_term_id":102,"footnotes":""},"categories":[66],"tags":[],"class_list":["post-1909","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-power-semiconductors"],"acf":[],"spectra_blocks_featured_image_url":{"thumbnail":{"url":"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/scr-module-heatsink-selection-thermal-evidence-hero-01-150x150.webp","width":150,"height":150},"medium":{"url":"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/scr-module-heatsink-selection-thermal-evidence-hero-01-300x169.webp","width":300,"height":169},"medium_large":{"url":"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/scr-module-heatsink-selection-thermal-evidence-hero-01-768x432.webp","width":768,"height":432},"large":{"url":"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/scr-module-heatsink-selection-thermal-evidence-hero-01-1024x576.webp","width":1024,"height":576},"full":{"url":"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/scr-module-heatsink-selection-thermal-evidence-hero-01.webp","width":1600,"height":900}},"spectra_blocks_author_info":{"display_name":"RITOKS","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/6d7d0fc73468198f994ab13ef6eb6558c53b6ed1ad86364d5165efe8bdf8eb4a?s=96&d=mm&r=g","author_link":"https:\/\/ritoks.com\/da\/author\/dazzlingwqbgmail-com\/","description":""},"_links":{"self":[{"href":"https:\/\/ritoks.com\/da\/wp-json\/wp\/v2\/posts\/1909","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ritoks.com\/da\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ritoks.com\/da\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ritoks.com\/da\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/ritoks.com\/da\/wp-json\/wp\/v2\/comments?post=1909"}],"version-history":[{"count":3,"href":"https:\/\/ritoks.com\/da\/wp-json\/wp\/v2\/posts\/1909\/revisions"}],"predecessor-version":[{"id":2228,"href":"https:\/\/ritoks.com\/da\/wp-json\/wp\/v2\/posts\/1909\/revisions\/2228"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ritoks.com\/da\/wp-json\/wp\/v2\/media\/1906"}],"wp:attachment":[{"href":"https:\/\/ritoks.com\/da\/wp-json\/wp\/v2\/media?parent=1909"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ritoks.com\/da\/wp-json\/wp\/v2\/categories?post=1909"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ritoks.com\/da\/wp-json\/wp\/v2\/tags?post=1909"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}