{"id":699,"date":"2026-09-05T16:51:06","date_gmt":"2026-09-05T16:51:06","guid":{"rendered":"https:\/\/ritoks.com\/?p=699"},"modified":"2026-09-20T06:54:43","modified_gmt":"2026-09-20T06:54:43","slug":"b-curve-vs-c-curve-vs-d-curve-mcb","status":"publish","type":"post","link":"https:\/\/ritoks.com\/da\/b-curve-vs-c-curve-vs-d-curve-mcb\/","title":{"rendered":"MCB\u2019er med B-kurve, C-kurve og D-kurve: Hvad er forskellen?"},"content":{"rendered":"<div class=\"wp-block-group alignfull has-ast-global-color-5-color has-ast-global-color-2-background-color has-text-color has-background is-layout-constrained wp-container-core-group-is-layout-a2d0cf3a wp-block-group-is-layout-constrained\" style=\"padding-top:64px;padding-right:24px;padding-bottom:64px;padding-left:24px\">\n\n\n<h1 class=\"wp-block-heading\">MCB\u2019er med B-kurve, C-kurve og D-kurve: Hvad er forskellen?<\/h1>\n\n\n\n<figure data-spectra-id=\"spectra-b6805897-4ed8-4714-a998-3267db4d7aeb\" class=\"wp-block-image aligncenter size-full has-custom-border\" ><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-family-hero.png\" alt=\"Typiske serier af AC-miniatyrafbrydere i et industrielt el-v\u00e6rksted\" class=\"wp-image-701\"  width=\"1672\" height=\"941\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-family-hero.png 1672w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-family-hero-600x338.png 600w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-family-hero-300x169.png 300w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-family-hero-1024x576.png 1024w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-family-hero-768x432.png 768w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-family-hero-1536x864.png 1536w\" sizes=\"auto, (max-width: 1672px) 100vw, 1672px\" \/><figcaption class=\"wp-element-caption\">Eksempler p\u00e5 typiske AC-MCB-formater vist i et industrielt el-milj\u00f8.<\/figcaption><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Kurverne B, C og D er forskellige udl\u00f8sningskarakteristika, der anvendes sammen med <a href=\"https:\/\/ritoks.com\/da\/product-category\/ac-power-protection\/miniature-circuit-breakers\/\">miniatureafbrydere (MCB\u2019er)<\/a>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Bogstaverne angiver ikke den aktuelle m\u00e6rkestr\u00f8m, afbryderkapacitet eller antal poler. I stedet er de med til at beskrive, hvordan afbryderen reagerer p\u00e5 h\u00f8jere kortvarig str\u00f8m i sit omr\u00e5de for \u00f8jeblikkelig udl\u00f8sning.<\/p>\n\n\n<\/div>\n\n\n\n<div class=\"wp-block-group alignfull is-layout-constrained wp-container-core-group-is-layout-105ba9aa wp-block-group-is-layout-constrained\" style=\"padding-top:64px;padding-right:24px;padding-bottom:64px;padding-left:24px\">\n\n\n<p class=\"wp-block-paragraph\">I producentens tekniske data angives der normalt f\u00f8lgende karakteristiske intervaller:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>B-kurve: ca. 3\u20135 \u00d7 In<\/li>\n<li>C-kurve: ca. 5\u201310 \u00d7 In<\/li>\n<li>D-kurve: ca. 10\u201320 \u00d7 In<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Her angiver \u00bbIn\u00ab afbryderens m\u00e6rkestr\u00f8m for den p\u00e5g\u00e6ldende karakteristik. <a href=\"https:\/\/www.eaton.com\/content\/dam\/eaton\/support\/apac-support-assets\/japan-cps-assets\/products\/2023promotions_lp\/sccr2024_pdf01.pdf\" target=\"_blank\" rel=\"noopener\">Eatons tekniske dokumentation<\/a> offentligg\u00f8r de samme B-, C- og D-kortslutningsudl\u00f8sningsomr\u00e5der for sine serier af miniatyrafbrydere.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Den praktiske forskel er, at de tre kurver t\u00e5ler forskellige niveauer af kortvarig str\u00f8m, f\u00f8r de n\u00e5r omr\u00e5det for \u00f8jeblikkelig udl\u00f8sning.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Det betyder ikke, at \u00e9n kurve generelt er bedre end en anden.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Den p\u00e5kr\u00e6vede kurve b\u00f8r baseres p\u00e5 det faktiske elektriske design, de forventede startstr\u00f8mforhold og dokumentationen for den valgte afbryder.<\/p>\n\n\n\n<h2 id=\"in-this-guide\" class=\"wp-block-heading\">I denne vejledning<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"#quick-comparison\">Hurtig sammenligning: B-kurve, C-kurve og D-kurve<\/a><\/li>\n<li><a href=\"#mcb-trip-curve\">Hvad er en MCB-udl\u00f8sningskurve?<\/a><\/li>\n<li><a href=\"#b-curve\">Hvad er en B-kurve-afbryder?<\/a><\/li>\n<li><a href=\"#c-curve\">Hvad er en MCB med C-kurve?<\/a><\/li>\n<li><a href=\"#d-curve\">Hvad er en D-kurve-afbryder?<\/a><\/li>\n<li><a href=\"#curve-availability\">Aktuel tilg\u00e6ngelighed af RITOKS-kurver<\/a><\/li>\n<li><a href=\"#selection-process\">S\u00e5dan v\u00e6lger du mellem B-, C- og D-kurveindstillingerne<\/a><\/li>\n<li><a href=\"#frequently-asked-questions\">Ofte stillede sp\u00f8rgsm\u00e5l<\/a><\/li>\n<\/ul>\n\n\n\n<h2 id=\"quick-comparison\" class=\"wp-block-heading\">Hurtig sammenligning: B-kurve, C-kurve og D-kurve<\/h2>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table><thead><tr><th>Karakteristika<\/th><th>F\u00e6lles omr\u00e5de for \u00f8jeblikkelig udl\u00f8sning<\/th><th>Generel baggrund for startstr\u00f8m<\/th><\/tr><\/thead><tbody><tr><td>B-kurve<\/td><td>3\u20135 \u00d7 In<\/td><td>Lavere forventet startstr\u00f8m<\/td><\/tr><tr><td>C-kurve<\/td><td>5\u201310 \u00d7 In<\/td><td>Der forventes en moderat startstr\u00f8m<\/td><\/tr><tr><td>D-kurven<\/td><td>10\u201320 \u00d7 In<\/td><td>Der forventes en h\u00f8jere startstr\u00f8m<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Disse intervaller beskriver de generelle egenskaber, som de st\u00f8rste MCB-producenter har dokumenteret. De b\u00f8r ikke betragtes som en modelspecifik RITOKS-tid-str\u00f8m-kurve, medmindre dette udtrykkeligt bekr\u00e6ftes i den n\u00f8jagtige RITOKS-produktdokumentation.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.eaton.com\/content\/dam\/eaton\/products\/electrical-circuit-protection\/industrial-miniature-circuit-breakers\/Industrial-breakers-catalog-ca08100005e.pdf\" target=\"_blank\" rel=\"noopener\">Eatons vejledning til industrielle mini-afbrydere<\/a>, beskriver for eksempel B-karakteristikken for situationer med lavt startstr\u00f8mforbrug, C for situationer med middel stort startstr\u00f8mforbrug og D for situationer med h\u00f8jt startstr\u00f8mforbrug. I anvendelsesvejledningen gives der eksempler s\u00e5som sm\u00e5 transformere og styreudstyr til C-karakteristika samt udstyr med h\u00f8jere indkoblingsstr\u00f8m, s\u00e5som motorer, transformere og str\u00f8mforsyninger, til D-karakteristika. Dette er typiske eksempler, ikke universelle regler for valg af belastning.<\/p>\n\n\n\n<figure data-spectra-id=\"spectra-18c0fb7e-87d2-4c5a-9cb3-54c6de591fa0\" class=\"wp-block-image aligncenter size-full has-custom-border\" ><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/b-c-d-curve-options-comparison.png\" alt=\"Konceptuel sammenligning af MCB-varianter med B-, C- og D-kurver\" class=\"wp-image-702\"  width=\"1672\" height=\"941\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/b-c-d-curve-options-comparison.png 1672w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/b-c-d-curve-options-comparison-600x338.png 600w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/b-c-d-curve-options-comparison-300x169.png 300w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/b-c-d-curve-options-comparison-1024x576.png 1024w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/b-c-d-curve-options-comparison-768x432.png 768w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/b-c-d-curve-options-comparison-1536x864.png 1536w\" sizes=\"auto, (max-width: 1672px) 100vw, 1672px\" \/><figcaption class=\"wp-element-caption\">Sammenligning af de konceptuelle kurver B, C og D. Kurvebetegnelsen er en af udv\u00e6lgelseskriterierne, og den n\u00f8jagtige modeldokumentation skal verificeres.<\/figcaption><\/figure>\n\n\n\n<h2 id=\"mcb-trip-curve\" class=\"wp-block-heading\">Hvad er en MCB-udl\u00f8sningskurve?<\/h2>\n\n\n<p class=\"wp-block-paragraph\">En MCB beskytter et kredsl\u00f8b mod overstr\u00f8m, men den m\u00e5de, den reagerer p\u00e5, afh\u00e6nger af mere end blot dens amperev\u00e6rdi.<\/p>\n<p class=\"wp-block-paragraph\">En rejsekarakteristik beskriver en del af denne reaktion.<\/p>\n<p class=\"wp-block-paragraph\">For MCB\u2019er med B-, C- og D-kurver er en af de mest synlige forskelle omr\u00e5det for \u00f8jeblikkelig eller magnetisk udl\u00f8sning.<\/p>\n<p class=\"wp-block-paragraph\">Lad os se p\u00e5 to afbrydere med samme nominelle str\u00f8mstyrke.<\/p>\n<p class=\"wp-block-paragraph\">En B-kurve-afbryder og en D-kurve-afbryder kan begge f\u00f8re den samme nominelle str\u00f8m under normale forhold, men deres omr\u00e5der for \u00f8jeblikkelig udl\u00f8sning kan variere betydeligt.<\/p>\n<p class=\"wp-block-paragraph\">Derfor:<\/p>\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p class=\"wp-block-paragraph\">\u201c32 A B-kurve\u201d og \u201c32 A D-kurve\u201d beskriver ikke den samme afbryderadf\u00e6rd, blot fordi begge afbrydere har en m\u00e6rkestr\u00f8m p\u00e5 32 A.<\/p><\/blockquote>\n\n\n<p class=\"wp-block-paragraph\">Kurven er derfor endnu en udv\u00e6lgelsesparameter ud over:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>nominel str\u00f8m<\/li>\n<li>sp\u00e6nding<\/li>\n<li>st\u00e6nger<\/li>\n<li>brudkapacitet<\/li>\n<li>monteringsformat<\/li>\n<li>den n\u00f8jagtige model<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">For yderligere oplysninger om udv\u00e6lgelsesprocessen, se <a href=\"https:\/\/ritoks.com\/da\/ac-mcb-selection-guide\/\">Vejledning til valg af AC-afbrydere: Str\u00f8m, poler, udl\u00f8sningskurve og afbrydelseskapacitet<\/a>.<\/p>\n\n\n\n<h2 id=\"b-curve\" class=\"wp-block-heading\">Hvad er en B-kurve-afbryder?<\/h2>\n\n\n<p class=\"wp-block-paragraph\">En A\/B-karakteristik anvender typisk et omr\u00e5de for \u00f8jeblikkelig udl\u00f8sning p\u00e5 ca. 3\u20135 gange m\u00e6rkestr\u00f8mmen.<\/p>\n<p class=\"wp-block-paragraph\">Generelt betyder det, at det \u00f8jeblikkelige magnetiske omr\u00e5de n\u00e5s ved et lavere multiplum af nominel str\u00f8m end ved C- eller D-karakteristikker.<\/p>\n<p class=\"wp-block-paragraph\">I producentens vejledning anbefales det typisk at anvende B-typer i situationer, hvor der forventes en relativt lav startstr\u00f8m.<\/p>\n<p class=\"wp-block-paragraph\">Det b\u00f8r dog ikke omdannes til en regel som f.eks.:<\/p>\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p class=\"wp-block-paragraph\">\u201cAlle belysningskredsl\u00f8b skal anvende B-kurven.\u201d<\/p><\/blockquote>\n<p class=\"wp-block-paragraph\">Det konkrete valg afh\u00e6nger af kredsl\u00f8bet, den forventede startstr\u00f8m, fejlforhold og de g\u00e6ldende konstruktionskrav.<\/p>\n\n\n<h3 class=\"wp-block-heading\">Aktuel tilg\u00e6ngelighed af RITOKS B-kurver<\/h3>\n\n\n<p class=\"wp-block-paragraph\">Aktuelt offentliggjort <a href=\"https:\/\/ritoks.com\/da\/product-category\/ac-power-protection\/\">RITOKS AC MCB-data<\/a> bekr\u00e6fter, at B-kurven er tilg\u00e6ngelig p\u00e5:<\/p>\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/ritoks.com\/da\/products\/miniature-circuit-breaker-63a-10ka\/\">RTSXD01<\/a> \u2014 B \/ C \/ D<\/li>\n<li>RTSXD03 \u2014 B \/ C<\/li>\n<li><a href=\"https:\/\/ritoks.com\/da\/products\/1pn-miniature-circuit-breaker-32a-6ka\/\">RTSXD02<\/a> \u2014 B \/ C<\/li>\n<li><a href=\"https:\/\/ritoks.com\/da\/products\/miniature-circuit-breaker-63a-10ka-pro\/\">RTSXD04<\/a> \u2014 B \/ C \/ D<\/li>\n<li><a href=\"https:\/\/ritoks.com\/da\/products\/m60-ac-miniature-circuit-breaker-6-63a\/\">RTS-ACM60<\/a> \u2014 B \/ C<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">K\u00f8rselsplanen for RTS-AC47 er p\u00e5 nuv\u00e6rende tidspunkt ikke bekr\u00e6ftet.<\/p>\n<p class=\"wp-block-paragraph\">Disse oplysninger bekr\u00e6fter udelukkende tilg\u00e6ngeligheden. De angiver ikke den n\u00f8jagtige modelspecifikke tid-str\u00f8m-kurve ud over den offentliggjorte kurvebetegnelse.<\/p>\n\n\n<h2 id=\"c-curve\" class=\"wp-block-heading\">Hvad er en MCB med C-kurve?<\/h2>\n\n\n<p class=\"wp-block-paragraph\">En C-karakteristik anvender typisk et omr\u00e5de for \u00f8jeblikkelig udl\u00f8sning p\u00e5 ca. 5\u201310 gange den nominelle str\u00f8m.<\/p>\n<p class=\"wp-block-paragraph\">Sammenlignet med B-karakteristikken giver dette mulighed for en h\u00f8jere kortvarig str\u00f8mmultiplikator, inden man n\u00e5r ind i omr\u00e5det for \u00f8jeblikkelig udl\u00f8sning.<\/p>\n<p class=\"wp-block-paragraph\">Eaton beskriver C-karakteristikken som velegnet til situationer med middelstor startstr\u00f8m og n\u00e6vner blandt andet sm\u00e5 transformere, belysning, pilotanordninger, styrekredsl\u00f8b og spoler som eksempler. Det er nyttig generel baggrundsinformation, men det betyder ikke, at hver eneste af disse anvendelser automatisk kr\u00e6ver en C-kurve.<\/p>\n\n\n<h3 class=\"wp-block-heading\">Aktuel tilg\u00e6ngelighed af RITOKS C-Curve<\/h3>\n\n<p class=\"wp-block-paragraph\">C-kurven er p\u00e5 nuv\u00e6rende tidspunkt den mest udbredte kurve blandt de offentliggjorte RITOKS AC MCB-familier:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>RTSXD01 \u2014 B \/ C \/ D<\/li>\n<li>RTSXD03 \u2014 B \/ C<\/li>\n<li>RTSXD02 \u2014 B \/ C<\/li>\n<li>RTSXD04 \u2014 B \/ C \/ D<\/li>\n<li>RTS-ACM60 \u2014 B \/ C<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">RTS-AC47 har heller ikke p\u00e5 nuv\u00e6rende tidspunkt nogen bekr\u00e6ftet kurvebetegnelse p\u00e5 hjemmesiden.<\/p>\n\n\n<h2 id=\"d-curve\" class=\"wp-block-heading\">Hvad er en D-kurve-afbryder?<\/h2>\n\n\n<p class=\"wp-block-paragraph\">En D-karakteristik anvender typisk et omr\u00e5de for \u00f8jeblikkelig udl\u00f8sning p\u00e5 ca. 10\u201320 gange den nominelle str\u00f8m.<\/p>\n<p class=\"wp-block-paragraph\">Dette er det h\u00f8jeste af de tre almindelige \u00f8jeblikkelige omr\u00e5der, der behandles her.<\/p>\n<p class=\"wp-block-paragraph\">I producentvejledninger k\u00e6des D-karakteristika ofte sammen med udstyr med h\u00f8j indkoblingsstr\u00f8m. Eaton n\u00e6vner motorer, transformere, str\u00f8mforsyninger og andre systemer med h\u00f8j induktans som typiske eksempler.<\/p>\n<p class=\"wp-block-paragraph\">Ordet \u00bbtypisk\u00ab er vigtigt.<\/p>\n<p class=\"wp-block-paragraph\">Det ville v\u00e6re uforsvarligt at konkludere, at:<\/p>\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p class=\"wp-block-paragraph\">\u201cMotor = D-kurve.\u201d<\/p><\/blockquote>\n<p class=\"wp-block-paragraph\">Et motorkredsl\u00f8b kan omfatte mange variable faktorer, herunder startkarakteristika og det overordnede beskyttelsesdesign. Afbryderkurven b\u00f8r derfor v\u00e6lges p\u00e5 baggrund af verificerede tekniske krav og ikke alene ud fra udstyrets betegnelse.<\/p>\n\n\n<h3 class=\"wp-block-heading\">Aktuel tilg\u00e6ngelighed af RITOKS D-kurver<\/h3>\n\n<p class=\"wp-block-paragraph\">De senest offentliggjorte RITOKS-data bekr\u00e6fter D-kurven for:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>RTSXD01<\/li>\n<li>RTSXD04<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">For de \u00f8vrige AC MCB-serier, der i \u00f8jeblikket er offentliggjort, er det ikke bekr\u00e6ftet p\u00e5 produktsiderne, om D-kurver er tilg\u00e6ngelige.<\/p>\n\n\n<h2 id=\"why-curves-differ\" class=\"wp-block-heading\">Hvorfor kurverne anvender forskellige \u00f8jeblikkelige omr\u00e5der<\/h2>\n\n\n<p class=\"wp-block-paragraph\">Elektrisk udstyr kan i kort tid tr\u00e6kke en str\u00f8m, der ligger over dets normale driftsniveau.<\/p>\n<p class=\"wp-block-paragraph\">Dette kan forekomme under h\u00e6ndelser som f.eks. tilslutning til str\u00f8mforsyningen eller opstart.<\/p>\n<p class=\"wp-block-paragraph\">Hvis afbryderens omr\u00e5de for \u00f8jeblikkelig udl\u00f8sning er indstillet for lavt i forhold til den forventede kortvarige str\u00f8m, kan afbryderen udl\u00f8se, selvom h\u00e6ndelsen var en del af den normale opstart af udstyret.<\/p>\n<p class=\"wp-block-paragraph\">Omvendt er det ikke n\u00f8dvendigvis bedre blot at v\u00e6lge en kurve med et st\u00f8rre \u00f8jeblikkeligt omr\u00e5de.<\/p>\n<p class=\"wp-block-paragraph\">Beskyttelsessystemet skal stadig reagere hensigtsm\u00e6ssigt p\u00e5 faktiske fejl.<\/p>\n<p class=\"wp-block-paragraph\">Derfor b\u00f8r B-, C- og D-karakteristika betragtes som forskellige beskyttelseskarakteristika og ikke som kvalitetsklasser.<\/p>\n<p class=\"wp-block-paragraph\">D er ikke en \u201cpremium\u201d-version af C, og C er ikke en \u201copgradering\u201d fra B.<\/p>\n\n\n<h2 id=\"same-rated-current\" class=\"wp-block-heading\">B mod C mod D ved samme nominel str\u00f8m<\/h2>\n\n\n<p class=\"wp-block-paragraph\">Forestil dig tre afbrydere, der alle har den samme nominelle str\u00f8m, In.<\/p>\n<p class=\"wp-block-paragraph\">Ved anvendelse af de almindelige karakteristiske intervaller:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>B n\u00e5r sit \u00f8jeblikkelige omr\u00e5de omkring 3\u20135 \u00d7 In<\/li>\n<li>C ca. 5\u201310 \u00d7 In<\/li>\n<li>D ca. 10\u201320 \u00d7 In<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">Udelukkende til illustration: Hvis In = 10 A, svarer disse multipler matematisk til:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>B: ca. 30\u201350 A<\/li>\n<li>C: ca. 50\u2013100 A<\/li>\n<li>D: ca. 100\u2013200 A<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">Dette regneeksempel illustrerer blot betydningen af multiplikatorerne. Det er ikke en anbefaling vedr\u00f8rende valg af produkt og b\u00f8r ikke betragtes som den n\u00f8jagtige funktionsm\u00e5de for en bestemt RITOKS-afbryder.<\/p>\n<p class=\"wp-block-paragraph\">Afbryderens faktiske adf\u00e6rd skal kontrolleres i forhold til producentens pr\u00e6cise tids- og str\u00f8mdata samt de g\u00e6ldende produktkrav.<\/p>\n\n\n<h2 id=\"curve-availability\" class=\"wp-block-heading\">Oversigt over den aktuelle tilg\u00e6ngelighed af RITOKS-kurver<\/h2>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table><thead><tr><th>RITOKS-modellen<\/th><th>B<\/th><th>C<\/th><th>D<\/th><th>Aktuel videnskabelig dokumentation<\/th><\/tr><\/thead><tbody><tr><td>RTSXD01<\/td><td>Ja<\/td><td>Ja<\/td><td>Ja<\/td><td>Offentliggjort tilg\u00e6ngelighed<\/td><\/tr><tr><td>RTSXD03<\/td><td>Ja<\/td><td>Ja<\/td><td>\u2014<\/td><td>Offentliggjort tilg\u00e6ngelighed<\/td><\/tr><tr><td>RTSXD02<\/td><td>Ja<\/td><td>Ja<\/td><td>\u2014<\/td><td>Offentliggjort tilg\u00e6ngelighed<\/td><\/tr><tr><td>RTSXD04<\/td><td>Ja<\/td><td>Ja<\/td><td>Ja<\/td><td>Offentliggjort tilg\u00e6ngelighed<\/td><\/tr><tr><td>RTS-ACM60<\/td><td>Ja<\/td><td>Ja<\/td><td>\u2014<\/td><td>Offentliggjort tilg\u00e6ngelighed<\/td><\/tr><tr><td>RTS-AC47<\/td><td>Ikke bekr\u00e6ftet<\/td><td>Ikke bekr\u00e6ftet<\/td><td>Ikke bekr\u00e6ftet<\/td><td>Kurven er ikke bekr\u00e6ftet<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n<p class=\"wp-block-paragraph\">Denne tabel b\u00f8r udelukkende bruges til at udv\u00e6lge kandidater inden for en produktfamilie.<\/p>\n<p class=\"wp-block-paragraph\">Det betyder ikke, at de tidligere n\u00e6vnte kurver fra den eksterne producent er de n\u00f8jagtige, testede tid-str\u00f8m-kurver for disse RITOKS-modeller.<\/p>\n\n\n<figure data-spectra-id=\"spectra-66316c34-bb44-4e7d-bdfb-65c61ed8c0db\" class=\"wp-block-image aligncenter size-full has-custom-border\" ><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-pole-formats-panel.png\" alt=\"Forskellige polkonfigurationer for AC-miniatyrafbrydere i et industrielt fordelingspanel\" class=\"wp-image-703\"  width=\"1672\" height=\"941\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-pole-formats-panel.png 1672w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-pole-formats-panel-600x338.png 600w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-pole-formats-panel-300x169.png 300w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-pole-formats-panel-1024x576.png 1024w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-pole-formats-panel-768x432.png 768w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-pole-formats-panel-1536x864.png 1536w\" sizes=\"auto, (max-width: 1672px) 100vw, 1672px\" \/><figcaption class=\"wp-element-caption\">Eksempler p\u00e5 AC MCB-produktvarianter; kurvetilg\u00e6ngelighed og elektriske specifikationer skal bekr\u00e6ftes for den konkrete model.<\/figcaption><\/figure>\n\n\n\n<h2 id=\"selection-process\" class=\"wp-block-heading\">S\u00e5dan v\u00e6lger du mellem B-, C- og D-kurveindstillingerne<\/h2>\n\n\n<p class=\"wp-block-paragraph\">Den praktiske indk\u00f8bsproces tager udgangspunkt i de kr\u00e6vede egenskaber, ikke i et g\u00e6t baseret p\u00e5 produktnavnet.<\/p>\n\n<h3 class=\"wp-block-heading\">1. Bekr\u00e6ft kravene til belastning og startstr\u00f8m<\/h3>\n<p class=\"wp-block-paragraph\">Find ud af, om projektdokumentationen allerede indeholder f\u00f8lgende:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>forventet startstr\u00f8m<\/li>\n<li>startstr\u00f8msadf\u00e6rd<\/li>\n<li>kr\u00e6vet kurve<\/li>\n<li>andre beskyttelsesm\u00e6ssige begr\u00e6nsninger<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">Hvis den \u00f8nskede kurve allerede er angivet, skal du bruge den som udgangspunkt.<\/p>\n\n<h3 class=\"wp-block-heading\">2. Bekr\u00e6ft den nominelle str\u00f8m<\/h3>\n<p class=\"wp-block-paragraph\">Udl\u00f8sningskurve og nominel str\u00f8m er to separate parametre.<\/p>\n<p class=\"wp-block-paragraph\">For eksempel:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>C16<\/li>\n<li>C32<\/li>\n<li>C63<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">De har alle betegnelsen \u00bbC\u00ab, men har forskellige str\u00f8mv\u00e6rdier.<\/p>\n<p class=\"wp-block-paragraph\">Du m\u00e5 ikke v\u00e6lge kurven f\u00f8rst og se bort fra den kr\u00e6vede afbryderstr\u00f8m.<\/p>\n\n<h3 class=\"wp-block-heading\">3. Bekr\u00e6ft brudkapaciteten<\/h3>\n<p class=\"wp-block-paragraph\">K\u00f8rselskurve og <a href=\"https:\/\/ritoks.com\/da\/6ka-vs-10ka-mcb-breaking-capacity\/\">6 kA vs. 10 kA \u2013 MCB\u2019s afbrydelseskapacitet<\/a> er ogs\u00e5 forskellige parametre.<\/p>\n<p class=\"wp-block-paragraph\">En betegnelse som A, B, C eller D siger ikke noget om, hvorvidt afbryderen har:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>6 kA<\/li>\n<li>10 kA<\/li>\n<li>eller en anden brudkapacitetsv\u00e6rdi<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">Denne egenskab skal kontrolleres separat p\u00e5 det p\u00e5g\u00e6ldende produkt.<\/p>\n\n<h3 class=\"wp-block-heading\">4. Bekr\u00e6ft polkonfigurationen<\/h3>\n<p class=\"wp-block-paragraph\">En p\u00e5kr\u00e6vet B\/C\/D-kurve kan kun v\u00e6re nyttig, hvis den samme produktfamilie ogs\u00e5 tilbyder f\u00f8lgende:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>1P<\/li>\n<li>1P+N<\/li>\n<li>2P<\/li>\n<li>3P<\/li>\n<li>3P+N<\/li>\n<li>4P<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">konfiguration.<\/p>\n\n<h3 class=\"wp-block-heading\">5. Kontroller den n\u00f8jagtige produktdokumentation<\/h3>\n<p class=\"wp-block-paragraph\">Det sidste trin er at kontrollere selve den valgte afbryder.<\/p>\n<p class=\"wp-block-paragraph\">G\u00e5 ikke ud fra, at:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>Alle B-kurver opf\u00f8rer sig ens uanset producent<\/li>\n<li>Hver C-kurve har identiske tid-str\u00f8m-tolerancer<\/li>\n<li>Hver D-kurve er egnet til enhver belastning med h\u00f8j startstr\u00f8m<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">Kurvebetegnelsen udg\u00f8r en del af den samlede produktspecifikation.<\/p>\n\n\n<h2 id=\"common-mistakes\" class=\"wp-block-heading\">Almindelige fejl ved valg af B\/C\/D-kurver<\/h2>\n\n\n<h3 class=\"wp-block-heading\">Behandling af B, C og D som kvalitetsniveauer<\/h3>\n<p class=\"wp-block-paragraph\">Der er tale om forskellige rejseegenskaber, ikke om \u201cgrundl\u00e6ggende\u201d, \u201cbedre\u201d og \u201cbedst\u201d.\u201d<\/p>\n\n<h3 class=\"wp-block-heading\">Valg ud fra navnet p\u00e5 filen alene<\/h3>\n<p class=\"wp-block-paragraph\">Udsagn som \u201cmotor betyder D-kurve\u201d er for generelle.<\/p>\n<p class=\"wp-block-paragraph\">Der skal tages h\u00f8jde for den forventede startstr\u00f8m og det faktiske elektriske design.<\/p>\n\n<h3 class=\"wp-block-heading\">At se bort fra den nominelle str\u00f8m<\/h3>\n<p class=\"wp-block-paragraph\">En korrekt kurve kombineret med den forkerte str\u00f8mv\u00e6rdi udg\u00f8r ikke et korrekt valg af afbryder.<\/p>\n\n<h3 class=\"wp-block-heading\">Ignorerer brudkapacitet<\/h3>\n<p class=\"wp-block-paragraph\">B\/C\/D-karakteristikken og bremseevnen er separate parametre.<\/p>\n\n<h3 class=\"wp-block-heading\">Antagelse om, at de eksterne kurvedata automatisk g\u00e6lder for alle RITOKS-modeller<\/h3>\n<p class=\"wp-block-paragraph\">De tal, der anvendes i denne vejledning \u2013 3\u20135 \u00d7 In, 5\u201310 \u00d7 In og 10\u201320 \u00d7 In \u2013 er generelle karakteristiske intervaller, der er underbygget af autoritative tekniske dokumenter fra producenten. P\u00e5 RITOKS\u2019 produktsider kan man i \u00f8jeblikket se, hvilke kurvebetegnelser der er tilg\u00e6ngelige, men der offentligg\u00f8res ikke komplette modelspecifikke tid-str\u00f8m-kurver.<\/p>\n\n<h3 class=\"wp-block-heading\">Oprettelse af en kurve uden modeldata<\/h3>\n<p class=\"wp-block-paragraph\">En graf, der ser realistisk ud, kan give indtryk af st\u00f8rre pr\u00e6cision, end det foreliggende bevismateriale kan underbygge.<\/p>\n<p class=\"wp-block-paragraph\">Indtil der foreligger pr\u00e6cis, RITOKS-modelspecifik dokumentation for tid-str\u00f8m-forholdet, b\u00f8r valg af kurve baseres p\u00e5 den offentliggjorte betegnelse og projektkravene frem for en selvudarbejdet graf.<\/p>\n\n\n<h2 id=\"request-technical-data\" class=\"wp-block-heading\">Hvorn\u00e5r b\u00f8r man anmode om yderligere tekniske data?<\/h2>\n\n\n<p class=\"wp-block-paragraph\">Ved en almindelig foresp\u00f8rgsel om indk\u00f8b kan det v\u00e6re nok at kende den kr\u00e6vede kurvebetegnelse for at udv\u00e6lge de tilg\u00e6ngelige modeller.<\/p>\n<p class=\"wp-block-paragraph\">Med henblik p\u00e5 en mere detaljeret teknisk gennemgang kan k\u00f8berne have brug for yderligere dokumentation, s\u00e5som:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>pr\u00e6cis tid-str\u00f8m-karakteristik<\/li>\n<li>tolerance over for \u00f8jeblikkelig udl\u00f8sning<\/li>\n<li>data om brudkapacitet<\/li>\n<li>g\u00e6ldende produktstandard<\/li>\n<li>koordinationsoplysninger, hvor det er n\u00f8dvendigt<\/li>\n<li>model-specifikke test- eller certificeringsdokumenter<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">Disse krav b\u00f8r specificeres for det p\u00e5g\u00e6ldende produkt og ikke blot antages ud fra bogstaverne B, C eller D alene.<\/p>\n\n\n<h2 id=\"frequently-asked-questions\" class=\"wp-block-heading\">Ofte stillede sp\u00f8rgsm\u00e5l<\/h2>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Hvad er den st\u00f8rste forskel mellem MCB\u2019er med B-, C- og D-kurve?<\/summary>\n<p class=\"wp-block-paragraph\">Den v\u00e6sentligste forskel, der behandles her, er omr\u00e5det for \u00f8jeblikkelig udl\u00f8sning. I almindelig dokumentation fra producenterne anvendes v\u00e6rdier p\u00e5 ca. 3\u20135 \u00d7 In for B, 5\u201310 \u00d7 In for C og 10\u201320 \u00d7 In for D.<\/p>\n<\/details>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Er C-kurven bedre end B-kurven?<\/summary>\n<p class=\"wp-block-paragraph\">Nej. De har forskellige udl\u00f8sningsegenskaber. Det rigtige valg afh\u00e6nger af kredsl\u00f8bet og de forventede startstr\u00f8mforhold.<\/p>\n<\/details>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Bruges D-kurven altid til motorer?<\/summary>\n<p class=\"wp-block-paragraph\">Nej. D-kurven forbindes normalt med anvendelser med h\u00f8jere startstr\u00f8m, og i producentens vejledning n\u00e6vnes motorer og transformere ofte som eksempler, men den korrekte kurve afh\u00e6nger af det konkrete udstyr og beskyttelseskonceptet.<\/p>\n<\/details>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Tilbyder RITOKS MCB\u2019er med B-, C- og D-kurver?<\/summary>\n<p class=\"wp-block-paragraph\">Ja, for udvalgte produktserier. RTSXD01 og RTSXD04 angiver i \u00f8jeblikket B\/C\/D-varianter. RTSXD02, RTSXD03 og RTS-ACM60 angiver B\/C. RTS-AC47 har i \u00f8jeblikket ingen bekr\u00e6ftet kurvebetegnelse.<\/p>\n<\/details>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Kan jeg udlede brudstyrken ud fra et kurvebrev?<\/summary>\n<p class=\"wp-block-paragraph\">Nej. Slagl\u00e6ngde og bremsekraft er to separate produktparametre, og begge b\u00f8r kontrolleres.<\/p>\n<\/details>\n\n\n\n<div class=\"wp-block-group has-ast-global-color-5-color has-ast-global-color-2-background-color has-text-color has-background is-layout-constrained wp-container-core-group-is-layout-737f6912 wp-block-group-is-layout-constrained\" style=\"border-radius:6px;margin-top:48px;padding-top:40px;padding-right:32px;padding-bottom:40px;padding-left:32px\">\n\n\n<h2 class=\"wp-block-heading\">Brug for hj\u00e6lp til at v\u00e6lge en udl\u00f8sningskurve til en MCB?<\/h2>\n\n\n<p class=\"wp-block-paragraph\">RITOKS tilbyder serier af miniatureafbrydere til vekselstr\u00f8m med forskellige str\u00f8mv\u00e6rdier, polkonfigurationer, afbrydelseskapaciteter og B\/C\/D-kurver.<\/p>\n<p class=\"wp-block-paragraph\">Brug en <a href=\"https:\/\/ritoks.com\/da\/ac-mcb-rfq-checklist\/\">Tjekliste til anmodning om tilbud p\u00e5 AC MCB<\/a> at stille f\u00f8lgende til r\u00e5dighed:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>Vekselstr\u00f8m<\/li>\n<li>kr\u00e6vet str\u00f8m<\/li>\n<li>polkonfiguration<\/li>\n<li>kr\u00e6vet k\u00f8rekurve<\/li>\n<li>kr\u00e6vet brudkapacitet<\/li>\n<li>antal<\/li>\n<li>ans\u00f8gning<\/li>\n<li>eventuel n\u00f8dvendig teknisk dokumentation<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">RITOKS kan derefter sammenholde foresp\u00f8rgslen med de aktuelt offentliggjorte produktfamilier og de bekr\u00e6ftede modeldata.<\/p>\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-ast-global-color-0-background-color has-background wp-element-button\" href=\"https:\/\/ritoks.com\/da\/product-category\/ac-power-protection\/miniature-circuit-breakers\/\">Se AC-miniaturafbrydere \u2192<\/a><\/div>\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-ast-global-color-0-background-color has-background wp-element-button\" href=\"https:\/\/ritoks.com\/da\/ac-mcb-selection-guide\/\">L\u00e6s vejledningen til valg af AC-afbrydere \u2192<\/a><\/div>\n<div class=\"wp-block-button is-style-outline is-style-outline--1\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/ritoks.com\/da\/contact-us\/\">Kontakt RITOKS \u2192 Anmod om et tilbud<\/a><\/div>\n<\/div>\n\n\n<\/div>\n\n\n<\/div>","protected":false},"excerpt":{"rendered":"<p>B Curve vs C Curve vs D Curve MCBs: What\u2019s the Difference? B, C and D curves are different tripping [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"no-sidebar","site-content-layout":"page-builder","ast-site-content-layout":"full-width-container","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"disabled","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"disabled","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ritoks_resource_detail_renderer":null,"ritoks_resource_product_cat_term_id":0,"footnotes":""},"categories":[64],"tags":[],"class_list":["post-699","post","type-post","status-publish","format-standard","hentry","category-circuit-protection"],"acf":[],"spectra_blocks_featured_image_url":null,"spectra_blocks_author_info":{"display_name":"RITOKS","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/6d7d0fc73468198f994ab13ef6eb6558c53b6ed1ad86364d5165efe8bdf8eb4a?s=96&d=mm&r=g","author_link":"https:\/\/ritoks.com\/da\/author\/dazzlingwqbgmail-com\/","description":""},"_links":{"self":[{"href":"https:\/\/ritoks.com\/da\/wp-json\/wp\/v2\/posts\/699","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ritoks.com\/da\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ritoks.com\/da\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ritoks.com\/da\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/ritoks.com\/da\/wp-json\/wp\/v2\/comments?post=699"}],"version-history":[{"count":4,"href":"https:\/\/ritoks.com\/da\/wp-json\/wp\/v2\/posts\/699\/revisions"}],"predecessor-version":[{"id":731,"href":"https:\/\/ritoks.com\/da\/wp-json\/wp\/v2\/posts\/699\/revisions\/731"}],"wp:attachment":[{"href":"https:\/\/ritoks.com\/da\/wp-json\/wp\/v2\/media?parent=699"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ritoks.com\/da\/wp-json\/wp\/v2\/categories?post=699"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ritoks.com\/da\/wp-json\/wp\/v2\/tags?post=699"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}