{"id":762,"date":"2026-09-07T01:52:16","date_gmt":"2026-09-07T01:52:16","guid":{"rendered":"https:\/\/ritoks.com\/?p=762"},"modified":"2026-10-04T06:58:24","modified_gmt":"2026-10-04T06:58:24","slug":"mds-30a-250a-vs-300a-1200a-bridge-rectifier-modules","status":"publish","type":"post","link":"https:\/\/ritoks.com\/da\/mds-30a-250a-vs-300a-1200a-bridge-rectifier-modules\/","title":{"rendered":"MDS 30A\u2013250A vs. 300A\u20131200A bro-ensrettermoduler: Model sammenligning"},"content":{"rendered":"<div class=\"wp-block-group alignfull has-ast-global-color-5-background-color has-background is-layout-constrained wp-container-core-group-is-layout-350090bf wp-block-group-is-layout-constrained\" style=\"padding-top:64px;padding-right:24px;padding-bottom:56px;padding-left:24px\">\n\n<p class=\"has-medium-font-size wp-block-paragraph\">RITOKS markedsf\u00f8rer i \u00f8jeblikket to serier af MDS-trefasede bro-ensrettermoduler, der d\u00e6kker forskellige str\u00f8mklasseomr\u00e5der:<\/p>\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-b4fe89e5 wp-block-columns-is-layout-flex\" style=\"margin-top:32px\">\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n\n<h3 class=\"wp-block-heading\"><a href=\"https:\/\/ritoks.com\/da\/products\/mds-three-phase-bridge-rectifier-30a-250a\/\">MDS 30A\u2013250A<\/a><\/h3>\n\n\n<figure data-spectra-id=\"spectra-3358123d-ef5b-4290-bc1e-f8bc7b299d43\" class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" height=\"617\" width=\"611\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/08\/ScreenShot_2026-08-30_150719_740.png\" alt=\"MDS-serien af trefasede bro-ensrettermoduler fra 30 A til 250 A\" class=\"wp-image-340\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/08\/ScreenShot_2026-08-30_150719_740.png 611w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/08\/ScreenShot_2026-08-30_150719_740-100x100.png 100w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/08\/ScreenShot_2026-08-30_150719_740-600x606.png 600w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/08\/ScreenShot_2026-08-30_150719_740-150x150.png 150w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/08\/ScreenShot_2026-08-30_150719_740-297x300.png 297w\" sizes=\"auto, (max-width: 611px) 100vw, 611px\" \/><\/figure>\n\n<\/div>\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n\n<h3 class=\"wp-block-heading\"><a href=\"https:\/\/ritoks.com\/da\/products\/mds-high-current-bridge-rectifier-300a-1200a\/\">MDS 300A\u20131200A<\/a><\/h3>\n\n\n<figure data-spectra-id=\"spectra-a7f35b02-59eb-41d4-9e39-2ac31e51494d\" class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" height=\"368\" width=\"523\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/08\/ScreenShot_2026-08-30_150805_720.png\" alt=\"MDS-serien af trefasede bro-ensrettermoduler til h\u00f8je str\u00f8mstyrker fra 300 A til 1200 A\" class=\"wp-image-342\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/08\/ScreenShot_2026-08-30_150805_720.png 523w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/08\/ScreenShot_2026-08-30_150805_720-300x211.png 300w\" sizes=\"auto, (max-width: 523px) 100vw, 523px\" \/><\/figure>\n\n<\/div>\n\n<\/div>\n\n<\/div>\n\n\n<div class=\"wp-block-group alignfull is-layout-constrained wp-container-core-group-is-layout-384c61b8 wp-block-group-is-layout-constrained\" style=\"padding-top:48px;padding-right:24px;padding-bottom:48px;padding-left:24px\">\n\n<p class=\"wp-block-paragraph\">Begge er MDS-serier af trefasede broensrettere, men deres offentliggjorte modelklasser er opdelt i to serier.<\/p>\n\n\n<p class=\"wp-block-paragraph\">Serien i den lavere ende omfatter modeller fra 30 A til 250 A.<\/p>\n\n\n<p class=\"wp-block-paragraph\">Serien i den h\u00f8jere ende omfatter modeller fra 300 A til 1200 A.<\/p>\n\n\n<p class=\"wp-block-paragraph\">Denne sammenligning fokuserer udelukkende p\u00e5 de forskelle, der p\u00e5 nuv\u00e6rende tidspunkt er offentliggjort.<\/p>\n\n\n<p class=\"wp-block-paragraph\">Den angiver ikke, at \u00e9n familie er bedre, mere effektiv eller mere sikker, og den omdanner ikke den nuv\u00e6rende klassificering til en universel regel for modulst\u00f8rrelse.<\/p>\n\n\n<p class=\"wp-block-paragraph\">For yderligere oplysninger om udv\u00e6lgelsesprincipperne henvises til <a href=\"https:\/\/ritoks.com\/da\/mds-bridge-rectifier-module-selection-guide\/\">Vejledning til valg af MDS-broensrettermodul<\/a>.<\/p>\n\n<\/div>\n\n\n<div class=\"wp-block-group alignfull has-ast-global-color-4-background-color has-background is-layout-constrained wp-container-core-group-is-layout-b3c3a14d wp-block-group-is-layout-constrained\" style=\"padding-top:56px;padding-right:24px;padding-bottom:56px;padding-left:24px\">\n\n<h2 id=\"mds-bridge-rectifier-module-comparison\" class=\"wp-block-heading\">Sammenligning af MDS-bro-ensrettermoduler<\/h2>\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table><thead><tr><th>Vare<\/th><th>MDS 30A\u2013250A<\/th><th>MDS 300A\u20131200A<\/th><\/tr><\/thead><tbody><tr><td>Produktfamilie<\/td><td>MDS trefaset bro-ensrettermodul<\/td><td>MDS trefaset bro-ensrettermodul til h\u00f8jstr\u00f8m<\/td><\/tr><tr><td>Offentliggjort nuv\u00e6rende sortiment<\/td><td>30A\u2013250A<\/td><td>300A\u20131200A<\/td><\/tr><tr><td>Offentliggjorte modelklasser<\/td><td>30 \/ 60 \/ 75 \/ 100 \/ 150 \/ 200 \/ 250A<\/td><td>300 \/ 400 \/ 500 \/ 600 \/ 800 \/ 1000 \/ 1200A<\/td><\/tr><tr><td>Version med pr\u00e6cis sp\u00e6nding<\/td><td>Bekr\u00e6ft den n\u00f8jagtige model<\/td><td>Bekr\u00e6ft den n\u00f8jagtige model<\/td><\/tr><tr><td>Leverand\u00f8rens reference for belastningsstr\u00f8m<\/td><td>Udgivet af model<\/td><td>Udgivet af model<\/td><\/tr><tr><td>Leverand\u00f8rens reference til k\u00f8leplade<\/td><td>Udgivet af Model Group<\/td><td>Udgivet af Model Group<\/td><\/tr><tr><td>K\u00f8lekonfiguration<\/td><td>Bekr\u00e6ft for anvendelse\/model<\/td><td>Bekr\u00e6ft for anvendelse\/model<\/td><\/tr><tr><td>Modulets dimensioner<\/td><td>Er ikke udgivet p\u00e5 nuv\u00e6rende tidspunkt<\/td><td>Er ikke offentliggjort p\u00e5 nuv\u00e6rende tidspunkt; modstridende henvisninger i oversigten skal verificeres<\/td><\/tr><tr><td>Terminalopstilling<\/td><td>Bekr\u00e6ft den n\u00f8jagtige model<\/td><td>Bekr\u00e6ft den n\u00f8jagtige model<\/td><\/tr><tr><td>Monteringsvejledning<\/td><td>Bekr\u00e6ft den n\u00f8jagtige model<\/td><td>Bekr\u00e6ft den n\u00f8jagtige model<\/td><\/tr><tr><td>Isoleringsdata<\/td><td>Ikke offentliggjort<\/td><td>Ikke offentliggjort<\/td><\/tr><tr><td>Certificering \/ standarder<\/td><td>Ikke offentliggjort<\/td><td>Ikke offentliggjort<\/td><\/tr><tr><td>Datablad til download<\/td><td>Ikke tilg\u00e6ngeligt i \u00f8jeblikket<\/td><td>Ikke tilg\u00e6ngeligt i \u00f8jeblikket<\/td><\/tr><tr><td>Endelig udv\u00e6lgelse<\/td><td>Der kr\u00e6ves verifikation af den n\u00f8jagtige model<\/td><td>Der kr\u00e6ves verifikation af den n\u00f8jagtige model<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n<p class=\"wp-block-paragraph\">Den st\u00f8rste forskel mellem de to familier er derfor deres offentliggjorte d\u00e6kning af de aktuelle klasser.<\/p>\n\n\n<p class=\"wp-block-paragraph\">Andre vigtige omr\u00e5der skal stadig bekr\u00e6ftes ved hj\u00e6lp af pr\u00e6cise modeller.<\/p>\n\n<\/div>\n\n\n<div class=\"wp-block-group alignfull has-border-color has-ast-global-color-5-background-color has-background is-layout-constrained wp-container-core-group-is-layout-52a4fad7 wp-block-group-is-layout-constrained\" style=\"border-color:#d8e3ef;border-width:1px;border-radius:6px;margin-top:32px;margin-bottom:32px;padding-top:32px;padding-right:24px;padding-bottom:32px;padding-left:24px\">\n\n<h3 class=\"wp-block-heading\">Offentliggjort sammenligning af aktuelle hold<\/h3>\n\n\n<figure data-spectra-id=\"spectra-cb7f3aa8-894d-4598-b22c-c07aa552316b\" class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/mds-published-current-classes-comparison.jpg\" alt=\"Offentliggjort sammenligning af de aktuelle klasser inden for broensrettermodulserierne MDS 30A\u2013250A og MDS 300A\u20131200A\" class=\"wp-image-763\" width=\"1774\" height=\"887\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/mds-published-current-classes-comparison.jpg 1774w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/mds-published-current-classes-comparison-600x300.jpg 600w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/mds-published-current-classes-comparison-300x150.jpg 300w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/mds-published-current-classes-comparison-1024x512.jpg 1024w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/mds-published-current-classes-comparison-768x384.jpg 768w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/mds-published-current-classes-comparison-1536x768.jpg 1536w\" sizes=\"auto, (max-width: 1774px) 100vw, 1774px\" \/><figcaption class=\"wp-element-caption\">Sammenligningen omfatter udelukkende offentliggjorte str\u00f8mklasser. Den n\u00f8jagtige sp\u00e6ndingsversion, belastningsforholdene, k\u00f8lekonfigurationen og den endelige modeldokumentation skal bekr\u00e6ftes inden bestilling.<\/figcaption><\/figure>\n\n<\/div>\n\n\n<div class=\"wp-block-group alignfull is-layout-constrained wp-container-core-group-is-layout-384c61b8 wp-block-group-is-layout-constrained\" style=\"padding-top:48px;padding-right:24px;padding-bottom:48px;padding-left:24px\">\n\n<h2 id=\"mds-30a-250a-published-model-classes\" class=\"wp-block-heading\">1. MDS 30A\u2013250A \u2013 Offentliggjorte modelklasser<\/h2>\n\n\n<p class=\"wp-block-paragraph\">MDS 30A\u2013250A-serien omfatter i \u00f8jeblikket syv str\u00f8mklasser:<\/p>\n\n\n<ul class=\"wp-block-list\">\n<li>MDS30A<\/li>\n\n<li>MDS60A<\/li>\n\n<li>MDS75A<\/li>\n\n<li>MDS100A<\/li>\n\n<li>MDS150A<\/li>\n\n<li>MDS200A<\/li>\n\n<li>MDS250A<\/li>\n<\/ul>\n\n\n<p class=\"wp-block-paragraph\">Denne familie d\u00e6kker den nedre del af det aktuelt offentliggjorte RITOKS MDS-sortiment.<\/p>\n\n\n<p class=\"wp-block-paragraph\">I forbindelse med indk\u00f8b kan en indk\u00f8ber bruge disse offentliggjorte kategorier til at vurdere, om denne produktfamilie er v\u00e6rd at unders\u00f8ge n\u00e6rmere i forhold til et eksisterende projektkrav.<\/p>\n\n\n<p class=\"wp-block-paragraph\">Det betyder ikke, at det n\u00e6rmeste aktuelle tal automatisk bliver det rigtige modul.<\/p>\n\n\n<p class=\"wp-block-paragraph\">Den n\u00f8jagtige sp\u00e6ndingsversion, anvendelsesbetingelserne, k\u00f8leanl\u00e6gget og modeldokumentationen skal stadig verificeres.<\/p>\n\n<\/div>\n\n\n<div class=\"wp-block-group alignfull is-layout-constrained wp-container-core-group-is-layout-384c61b8 wp-block-group-is-layout-constrained\" style=\"padding-top:48px;padding-right:24px;padding-bottom:48px;padding-left:24px\">\n\n<h2 id=\"mds-300a-1200a-published-model-classes\" class=\"wp-block-heading\">2. MDS 300A\u20131200A \u2013 Offentliggjorte modelklasser<\/h2>\n\n\n<p class=\"wp-block-paragraph\">MDS-serien med h\u00f8jere str\u00f8mstyrke omfatter ligeledes syv str\u00f8mklasser:<\/p>\n\n\n<ul class=\"wp-block-list\">\n<li>MDS300A<\/li>\n\n<li>MDS400A<\/li>\n\n<li>MDS500A<\/li>\n\n<li>MDS600A<\/li>\n\n<li>MDS800A<\/li>\n\n<li>MDS1000A<\/li>\n\n<li>MDS1200A<\/li>\n<\/ul>\n\n\n<p class=\"wp-block-paragraph\">Dette giver et angivet omr\u00e5de fra 300 A til 1200 A.<\/p>\n\n\n<p class=\"wp-block-paragraph\">Ligesom i 30A\u2013250A-serien angiver disse tal modelklasser.<\/p>\n\n\n<p class=\"wp-block-paragraph\">De fasts\u00e6tter ikke en regel som f.eks.:<\/p>\n\n\n<p class=\"wp-block-paragraph\">belastningsstr\u00f8m = den kr\u00e6vede MDS-str\u00f8mklasse<\/p>\n\n\n<p class=\"wp-block-paragraph\">eller:<\/p>\n\n\n<p class=\"wp-block-paragraph\">V\u00e6lg den n\u00e6ste aktuelle klasse over belastningen.<\/p>\n\n\n<p class=\"wp-block-paragraph\">Den endelige egnethed afh\u00e6nger af den fulde ans\u00f8gning og de n\u00f8jagtige modeloplysninger.<\/p>\n\n<\/div>\n\n\n<div class=\"wp-block-group alignfull is-layout-constrained wp-container-core-group-is-layout-384c61b8 wp-block-group-is-layout-constrained\" style=\"padding-top:48px;padding-right:24px;padding-bottom:48px;padding-left:24px\">\n\n<h2 id=\"the-published-boundary-is-250a-to-300a\" class=\"wp-block-heading\">3. Den offentliggjorte gr\u00e6nse ligger mellem 250A og 300A<\/h2>\n\n\n<p class=\"wp-block-paragraph\">De nuv\u00e6rende RITOKS-produktsider skaber en tydelig afgr\u00e6nsning af produktserien:<\/p>\n\n\n<p class=\"wp-block-paragraph\">MDS 30A\u2013250A-serien: h\u00f8jeste angivne klasse = 250 A<\/p>\n\n\n<p class=\"wp-block-paragraph\">MDS 300A\u20131200A-serien: laveste angivne klasse = 300 A<\/p>\n\n\n<p class=\"wp-block-paragraph\">Der er ingen modeller i klassen 251A\u2013299A angivet p\u00e5 disse to aktuelle produktsider.<\/p>\n\n\n<p class=\"wp-block-paragraph\">Denne udtalelse g\u00e6lder udelukkende for den nuv\u00e6rende offentliggjorte RITOKS-familiestruktur.<\/p>\n\n\n<p class=\"wp-block-paragraph\">Det betyder ikke:<\/p>\n\n\n<ul class=\"wp-block-list\">\n<li>der findes ingen andre vurderinger p\u00e5 det bredere marked<\/li>\n\n<li>For alle belastninger under 300 A skal der anvendes 250 A<\/li>\n\n<li>For alle behov over 250 A b\u00f8r der automatisk anvendes 300 A<\/li>\n\n<li>300A er et universelt overgangssted i konstruktionen af bro-ensrettere<\/li>\n<\/ul>\n\n\n<p class=\"wp-block-paragraph\">Afgr\u00e6nsningen hj\u00e6lper ganske enkelt k\u00f8berne med at forst\u00e5, hvordan de to RITOKS-produktfamilier er opbygget.<\/p>\n\n<\/div>\n\n\n<div class=\"wp-block-group alignfull is-layout-constrained wp-container-core-group-is-layout-384c61b8 wp-block-group-is-layout-constrained\" style=\"padding-top:48px;padding-right:24px;padding-bottom:48px;padding-left:24px\">\n\n<h2 id=\"supplier-load-current-reference-data-30a-250a-family\" class=\"wp-block-heading\">4. Leverand\u00f8rens referencedata for belastningsstr\u00f8m: 30 A\u2013250 A-serien<\/h2>\n\n\n<p class=\"wp-block-paragraph\">P\u00e5 siden om MDS 30A\u2013250A findes der i \u00f8jeblikket leverand\u00f8rens referencev\u00e6rdier for resistive og induktive belastningsforhold.<\/p>\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table><thead><tr><th>Modelklasse<\/th><th>Resistiv reference<\/th><th>Induktiv henvisning<\/th><\/tr><\/thead><tbody><tr><td>30A<\/td><td>27A<\/td><td>18A<\/td><\/tr><tr><td>60A<\/td><td>42A<\/td><td>36A<\/td><\/tr><tr><td>75A<\/td><td>50A<\/td><td>40A<\/td><\/tr><tr><td>100A<\/td><td>65A<\/td><td>45A<\/td><\/tr><tr><td>150A<\/td><td>100A<\/td><td>75A<\/td><\/tr><tr><td>200A<\/td><td>130A<\/td><td>100A<\/td><\/tr><tr><td>250A<\/td><td>175A<\/td><td>125A<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n<p class=\"wp-block-paragraph\">Dette er leverand\u00f8rens referencev\u00e6rdier, der er knyttet til de anf\u00f8rte modeller.<\/p>\n\n\n<p class=\"wp-block-paragraph\">De b\u00f8r ikke omregnes til et universelt forhold eller en universel st\u00f8rrelsesformel.<\/p>\n\n\n<p class=\"wp-block-paragraph\">Denne artikel udleder for eksempel ikke:<\/p>\n\n\n<ul class=\"wp-block-list\">\n<li>en belastningsstr\u00f8msmultiplikator<\/li>\n\n<li>en fast procentdel for reduktion af ydeevnen<\/li>\n\n<li>en fast sikkerhedsmargen<\/li>\n\n<li>en automatisk regel for modelvalg<\/li>\n<\/ul>\n\n\n<p class=\"wp-block-paragraph\">Brug tabellen som reference, og tjek den konkrete anvendelse, inden du v\u00e6lger det n\u00f8jagtige modul.<\/p>\n\n<\/div>\n\n\n<div class=\"wp-block-group alignfull is-layout-constrained wp-container-core-group-is-layout-384c61b8 wp-block-group-is-layout-constrained\" style=\"padding-top:48px;padding-right:24px;padding-bottom:48px;padding-left:24px\">\n\n<h2 id=\"supplier-load-current-reference-data-300a-1200a-family\" class=\"wp-block-heading\">5. Leverand\u00f8rens referencedata for belastningsstr\u00f8m: 300 A\u20131200 A-serien<\/h2>\n\n\n<p class=\"wp-block-paragraph\">P\u00e5 siden om MDS 300A\u20131200A findes et tilsvarende s\u00e6t referencev\u00e6rdier.<\/p>\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table><thead><tr><th>Modelklasse<\/th><th>Resistiv reference<\/th><th>Induktiv henvisning<\/th><\/tr><\/thead><tbody><tr><td>300 A<\/td><td>190A<\/td><td>135A<\/td><\/tr><tr><td>400A<\/td><td>250A<\/td><td>150A<\/td><\/tr><tr><td>500A<\/td><td>300 A<\/td><td>180A<\/td><\/tr><tr><td>600A<\/td><td>340A<\/td><td>204A<\/td><\/tr><tr><td>800A<\/td><td>360A<\/td><td>216A<\/td><\/tr><tr><td>1000A<\/td><td>540A<\/td><td>324A<\/td><\/tr><tr><td>1200A<\/td><td>580A<\/td><td>340A<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n<p class=\"wp-block-paragraph\">Disse v\u00e6rdier skal fortolkes p\u00e5 samme m\u00e5de:<\/p>\n\n\n<p class=\"wp-block-paragraph\">modelspecifikke leverand\u00f8rreferencedata, ikke en universel teknisk regel.<\/p>\n\n\n<p class=\"wp-block-paragraph\">Man b\u00f8r ikke beregne et forholdstal ud fra \u00e9n r\u00e6kke og anvende det p\u00e5 andre MDS-modeller eller -applikationer.<\/p>\n\n\n<p class=\"wp-block-paragraph\">Drifts- og k\u00f8leforholdene spiller stadig en rolle.<\/p>\n\n<\/div>\n\n\n<div class=\"wp-block-group alignfull is-layout-constrained wp-container-core-group-is-layout-384c61b8 wp-block-group-is-layout-constrained\" style=\"padding-top:48px;padding-right:24px;padding-bottom:48px;padding-left:24px\">\n\n<h2 id=\"what-the-two-load-reference-tables-can-tell-you\" class=\"wp-block-heading\">6. Hvad de to belastningsreferencetabeller kan fort\u00e6lle dig<\/h2>\n\n\n<p class=\"wp-block-paragraph\">Begge familier giver oplysninger, der kan hj\u00e6lpe en k\u00f8ber med at udarbejde en mere konkret foresp\u00f8rgsel om en bestemt model.<\/p>\n\n\n<p class=\"wp-block-paragraph\">De kan bruges til:<\/p>\n\n\n<ul class=\"wp-block-list\">\n<li>identificere offentliggjorte modelklasser<\/li>\n\n<li>gennemg\u00e5 leverand\u00f8rens referencedata for en bestemt klasse<\/li>\n\n<li>forberede ans\u00f8gningsoplysningerne til godkendelse<\/li>\n\n<li>find frem til de sp\u00f8rgsm\u00e5l, der b\u00f8r afklares, inden der afgives en ordre<\/li>\n<\/ul>\n\n\n<p class=\"wp-block-paragraph\">De b\u00f8r ikke bruges til at h\u00e6vde:<\/p>\n\n\n<ul class=\"wp-block-list\">\n<li>et generelt forhold mellem belastningsstr\u00f8m og modulets nominelle v\u00e6rdi<\/li>\n\n<li>garanti for, at produktet passer til en bestemt maskine<\/li>\n\n<li>en automatisk regel for reduktion af belastning<\/li>\n\n<li>en anbefalet procentdel for overdimensionering<\/li>\n<\/ul>\n\n\n<p class=\"wp-block-paragraph\">Hvis et projekt kr\u00e6ver tekniske beregninger, skal disse beregninger baseres p\u00e5 de faktiske elektriske og termiske forhold samt verificerede enhedsdata.<\/p>\n\n<\/div>\n\n\n<div class=\"wp-block-group alignfull is-layout-constrained wp-container-core-group-is-layout-384c61b8 wp-block-group-is-layout-constrained\" style=\"padding-top:48px;padding-right:24px;padding-bottom:48px;padding-left:24px\">\n\n<h2 id=\"published-heatsink-references-also-differ\" class=\"wp-block-heading\">7. De offentliggjorte referencer til k\u00f8leplader varierer ogs\u00e5<\/h2>\n\n\n<p class=\"wp-block-paragraph\">Begge MDS-produktsider indeholder oplysninger om k\u00f8leplader med leverand\u00f8rhenvisning.<\/p>\n\n\n<p class=\"wp-block-paragraph\">MDS 30A\u2013250A<\/p>\n\n\n<p class=\"wp-block-paragraph\">Blandt de offentliggjorte referencegrupper er:<\/p>\n\n\n<p class=\"wp-block-paragraph\">30A\u2013100A<\/p>\n\n\n<p class=\"wp-block-paragraph\">125 \u00d7 95 \u00d7 50 mm referencek\u00f8leplade<\/p>\n\n\n<p class=\"wp-block-paragraph\">150A\u2013250A<\/p>\n\n\n<ul class=\"wp-block-list\">\n<li>150 \u00d7 100 \u00d7 80 mm referencek\u00f8leplade<\/li>\n\n<li>MDS 300A\u20131200A<\/li>\n<\/ul>\n\n\n<p class=\"wp-block-paragraph\">Blandt de offentliggjorte referencegrupper er:<\/p>\n\n\n<p class=\"wp-block-paragraph\">300A\u2013600A<\/p>\n\n\n<p class=\"wp-block-paragraph\">150 \u00d7 125 \u00d7 135 mm referencek\u00f8ler<\/p>\n\n\n<p class=\"wp-block-paragraph\">800A\u20131200A<\/p>\n\n\n<p class=\"wp-block-paragraph\">250 \u00d7 141 \u00d7 135 mm referencek\u00f8leplade<\/p>\n\n\n<p class=\"wp-block-paragraph\">Disse m\u00e5l g\u00e6lder for leverand\u00f8rens standardk\u00f8leplade, ikke for ensrettermodulets m\u00e5l.<\/p>\n\n\n<p class=\"wp-block-paragraph\">Den skelnen er vigtig.<\/p>\n\n\n<p class=\"wp-block-paragraph\">Brug ikke tallene som:<\/p>\n\n\n<ul class=\"wp-block-list\">\n<li>modulpakkens dimensioner<\/li>\n\n<li>monteringsm\u00e5l<\/li>\n\n<li>kr\u00e6vede dimensioner for universal-k\u00f8lepladen<\/li>\n\n<li>dokumentation for den endelige termiske ydeevne<\/li>\n<\/ul>\n\n\n<p class=\"wp-block-paragraph\">Det konkrete k\u00f8lesystem skal kontrolleres i forhold til den valgte model og anvendelse.<\/p>\n\n<\/div>\n\n\n<div class=\"wp-block-group alignfull is-layout-constrained wp-container-core-group-is-layout-384c61b8 wp-block-group-is-layout-constrained\" style=\"padding-top:48px;padding-right:24px;padding-bottom:48px;padding-left:24px\">\n\n<h2 id=\"higher-current-class-does-not-establish-a-better-cooling-solution\" class=\"wp-block-heading\">8. En h\u00f8jere str\u00f8mklasse er ikke ensbetydende med en bedre k\u00f8le l\u00f8sning<\/h2>\n\n\n<p class=\"wp-block-paragraph\">Det kan v\u00e6re fristende at sammenligne de to serier og konkludere, at serien med den h\u00f8jere str\u00f8mstyrke automatisk kr\u00e6ver en bestemt k\u00f8lemetode.<\/p>\n\n\n<p class=\"wp-block-paragraph\">Den nuv\u00e6rende viden underst\u00f8tter ikke denne generelle konklusion.<\/p>\n\n\n<p class=\"wp-block-paragraph\">Den korrekte sammenligning er:<\/p>\n\n\n<ul class=\"wp-block-list\">\n<li>Begge familier offentligg\u00f8r oplysninger om k\u00f8leplader<\/li>\n\n<li>Disse referencest\u00f8rrelser varierer fra modelgruppe til modelgruppe<\/li>\n\n<li>Den endelige termiske konfiguration afh\u00e6nger af den konkrete model og anvendelse<\/li>\n<\/ul>\n\n\n<p class=\"wp-block-paragraph\">De nuv\u00e6rende produktoplysninger bekr\u00e6fter ikke, at alle MDS 300A\u20131200A-varianter:<\/p>\n\n\n<ul class=\"wp-block-list\">\n<li>anvender den samme k\u00f8lemetode<\/li>\n\n<li>kr\u00e6ver vandk\u00f8ling<\/li>\n\n<li>anvender en s\u00e6rlig k\u00f8leflade<\/li>\n\n<li>bliver varmere end alle modeller i klassen 30 A\u2013250 A<\/li>\n<\/ul>\n\n\n<p class=\"wp-block-paragraph\">K\u00f8ling b\u00f8r fortsat v\u00e6re et punkt, der verificeres ved hj\u00e6lp af en pr\u00e6cis model.<\/p>\n\n<\/div>\n\n\n<div class=\"wp-block-group alignfull is-layout-constrained wp-container-core-group-is-layout-384c61b8 wp-block-group-is-layout-constrained\" style=\"padding-top:48px;padding-right:24px;padding-bottom:48px;padding-left:24px\">\n\n<h2 id=\"voltage-is-not-a-useful-side-by-side-comparison-yet\" class=\"wp-block-heading\">9. Sp\u00e6nding er endnu ikke et brugbart sammenligningsgrundlag<\/h2>\n\n\n<p class=\"wp-block-paragraph\">De nuv\u00e6rende produktsider indeholder ikke tilstr\u00e6kkelige, verificerede oplysninger p\u00e5 modelniveau til, at man kan foretage en p\u00e5lidelig sammenligning af sp\u00e6ndingsomr\u00e5det mellem disse to produktserier.<\/p>\n\n\n<p class=\"wp-block-paragraph\">For begge:<\/p>\n\n\n<p class=\"wp-block-paragraph\">Version med pr\u00e6cis sp\u00e6nding \/ suffiks: Bekr\u00e6ft den valgte model.<\/p>\n\n\n<p class=\"wp-block-paragraph\">Derfor b\u00f8r denne artikel ikke h\u00e6vde:<\/p>\n\n\n<ul class=\"wp-block-list\">\n<li>identiske sp\u00e6ndingsomr\u00e5der<\/li>\n\n<li>forskellige sp\u00e6ndingsomr\u00e5der<\/li>\n\n<li>tilg\u00e6ngelighed af universalsp\u00e6nding<\/li>\n\n<li>et bestemt sp\u00e6ndingssuffiks for hver str\u00f8mklasse<\/li>\n<\/ul>\n\n\n<p class=\"wp-block-paragraph\">Sp\u00e6ndingen b\u00f8r i stedet angives i k\u00f8berens anmodning om modelbekr\u00e6ftelse.<\/p>\n\n<\/div>\n\n\n<div class=\"wp-block-group alignfull is-layout-constrained wp-container-core-group-is-layout-384c61b8 wp-block-group-is-layout-constrained\" style=\"padding-top:48px;padding-right:24px;padding-bottom:48px;padding-left:24px\">\n\n<h2 id=\"mechanical-dimensions-cannot-yet-be-compared\" class=\"wp-block-heading\">10. De mekaniske dimensioner kan endnu ikke sammenlignes<\/h2>\n\n\n<p class=\"wp-block-paragraph\">De nuv\u00e6rende sider indeholder heller ikke tilstr\u00e6kkelige, verificerede oplysninger til at kunne sammenligne pakkest\u00f8rrelser.<\/p>\n\n\n<p class=\"wp-block-paragraph\">For MDS 30A\u2013250A-serien skal de modelspecifikke oplysninger om kabinet og ydre dimensioner stadig verificeres.<\/p>\n\n\n<p class=\"wp-block-paragraph\">For MDS 300A\u20131200A-serien indeholder de nuv\u00e6rende oplysninger modstridende henvisninger til dimensioner, som ikke b\u00f8r afklares ved g\u00e6tteri.<\/p>\n\n\n<p class=\"wp-block-paragraph\">Du b\u00f8r derfor ikke sammenligne:<\/p>\n\n\n<ul class=\"wp-block-list\">\n<li>modulbredde<\/li>\n\n<li>modull\u00e6ngde<\/li>\n\n<li>modulets h\u00f8jde<\/li>\n\n<li>afstanden mellem monteringshullerne<\/li>\n\n<li>terminalplaceringer<\/li>\n\n<li>v\u00e6gt<\/li>\n\n<li>k\u00f8leflade<\/li>\n<\/ul>\n\n\n<p class=\"wp-block-paragraph\">fra de aktuelle artikeldata eller produktbilleder.<\/p>\n\n\n<p class=\"wp-block-paragraph\">N\u00e5r det kommer til pasform, skal du anmode om den godkendte tegning for den n\u00f8jagtige model.<\/p>\n\n<\/div>\n\n\n<div class=\"wp-block-group alignfull is-layout-constrained wp-container-core-group-is-layout-384c61b8 wp-block-group-is-layout-constrained\" style=\"padding-top:48px;padding-right:24px;padding-bottom:48px;padding-left:24px\">\n\n<h2 id=\"product-images-are-not-mechanical-drawings\" class=\"wp-block-heading\">11. Produktbilleder er ikke tekniske tegninger<\/h2>\n\n\n<p class=\"wp-block-paragraph\">De eksisterende RITOKS-produktbilleder er nyttige til visuelt at genkende de enkelte produktserier.<\/p>\n\n\n<p class=\"wp-block-paragraph\">De er ikke egnet som bevismateriale til at fastsl\u00e5:<\/p>\n\n\n<ul class=\"wp-block-list\">\n<li>n\u00f8jagtige modulm\u00e5l<\/li>\n\n<li>terminalopgave<\/li>\n\n<li>terminalpolarisering<\/li>\n\n<li>afstanden mellem monteringshullerne<\/li>\n\n<li>sp\u00e6nding<\/li>\n\n<li>isolering<\/li>\n\n<li>internt kredsl\u00f8b<\/li>\n\n<li>certificering<\/li>\n<\/ul>\n\n\n<p class=\"wp-block-paragraph\">En k\u00f8ber, der har brug for data vedr\u00f8rende mekanisk integration, b\u00f8r anmode om verificeret dokumentation i stedet for at skalere eller fortolke produktbilledet.<\/p>\n\n<\/div>\n\n\n<div class=\"wp-block-group alignfull is-layout-constrained wp-container-core-group-is-layout-384c61b8 wp-block-group-is-layout-constrained\" style=\"padding-top:48px;padding-right:24px;padding-bottom:48px;padding-left:24px\">\n\n<h2 id=\"certification-and-standards-are-not-yet-a-comparison-point\" class=\"wp-block-heading\">12. Certificering og standarder udg\u00f8r endnu ikke et sammenligningsgrundlag<\/h2>\n\n\n<p class=\"wp-block-paragraph\">Ingen af de unders\u00f8gte familier offentligg\u00f8r i \u00f8jeblikket tilstr\u00e6kkeligt med dokumentation til, at der kan foretages en sammenligning af certificeringerne.<\/p>\n\n\n<p class=\"wp-block-paragraph\">Nuv\u00e6rende status:<\/p>\n\n\n<p class=\"wp-block-paragraph\">MDS 30A\u2013250A<\/p>\n\n\n<ul class=\"wp-block-list\">\n<li>certificering: ikke offentliggjort<\/li>\n\n<li>standarder: ikke offentliggjort<\/li>\n<\/ul>\n\n\n<p class=\"wp-block-paragraph\">MDS 300A\u20131200A<\/p>\n\n\n<ul class=\"wp-block-list\">\n<li>certificering: ikke offentliggjort<\/li>\n\n<li>standarder: ikke offentliggjort<\/li>\n<\/ul>\n\n\n<p class=\"wp-block-paragraph\">Hvis der kr\u00e6ves certificering eller markedsgodkendelse, bedes De i foresp\u00f8rgslen angive, hvilket dokument der pr\u00e6cist er behov for.<\/p>\n\n\n<p class=\"wp-block-paragraph\">M\u00e5 ikke behandles:<\/p>\n\n\n<ul class=\"wp-block-list\">\n<li>produkttype<\/li>\n\n<li>formulering af ans\u00f8gningen<\/li>\n\n<li>leverand\u00f8rtabel<\/li>\n\n<li>produktbillede<\/li>\n<\/ul>\n\n\n<p class=\"wp-block-paragraph\">som bevis for certificering.<\/p>\n\n<\/div>\n\n\n<div class=\"wp-block-group alignfull is-layout-constrained wp-container-core-group-is-layout-384c61b8 wp-block-group-is-layout-constrained\" style=\"padding-top:48px;padding-right:24px;padding-bottom:48px;padding-left:24px\">\n\n<h2 id=\"neither-family-currently-provides-a-downloadable-datasheet\" class=\"wp-block-heading\">13. Ingen af de to familier stiller i \u00f8jeblikket et datablad til r\u00e5dighed, der kan downloades<\/h2>\n\n\n<p class=\"wp-block-paragraph\">De nuv\u00e6rende produktsider indeholder ikke et modelspecifikt datablad, der kan downloades.<\/p>\n\n\n<p class=\"wp-block-paragraph\">Derfor er det endnu vigtigere at f\u00e5 bekr\u00e6ftet den n\u00f8jagtige model i forbindelse med projekter, der kr\u00e6ver:<\/p>\n\n\n<ul class=\"wp-block-list\">\n<li>m\u00e5ltegninger<\/li>\n\n<li>terminaloplysninger<\/li>\n\n<li>Bekr\u00e6ftelse af sp\u00e6nding\/version<\/li>\n\n<li>monteringsvejledning<\/li>\n\n<li>termiske oplysninger<\/li>\n\n<li>dokumentation for certificering<\/li>\n<\/ul>\n\n\n<p class=\"wp-block-paragraph\">Disse oplysninger b\u00f8r indhentes for den konkrete model, der overvejes.<\/p>\n\n<\/div>\n\n\n<div class=\"wp-block-group alignfull is-layout-constrained wp-container-core-group-is-layout-384c61b8 wp-block-group-is-layout-constrained\" style=\"padding-top:48px;padding-right:24px;padding-bottom:48px;padding-left:24px\">\n\n<h2 id=\"which-family-should-you-review-first\" class=\"wp-block-heading\">14. Hvilken familie b\u00f8r du gennemg\u00e5 f\u00f8rst?<\/h2>\n\n\n<p class=\"wp-block-paragraph\">Den enkleste og sikreste m\u00e5de at skelne p\u00e5 er det offentliggjorte str\u00f8mklasseinterval.<\/p>\n\n\n<p class=\"wp-block-paragraph\">Se n\u00e6rmere p\u00e5 MDS 30A\u2013250A-serien, n\u00e5r<\/p>\n\n\n<p class=\"wp-block-paragraph\">Projektkravet falder ind under en af de offentliggjorte kategorier:<\/p>\n\n\n<p class=\"wp-block-paragraph\">30 \/ 60 \/ 75 \/ 100 \/ 150 \/ 200 \/ 250A<\/p>\n\n\n<p class=\"wp-block-paragraph\">Bekr\u00e6ft derefter:<\/p>\n\n\n<ul class=\"wp-block-list\">\n<li>versionen med n\u00f8jagtig sp\u00e6nding<\/li>\n\n<li>oplysninger om ans\u00f8gning\/indl\u00e6sning<\/li>\n\n<li>k\u00f8lesystem<\/li>\n\n<li>den n\u00f8jagtige model<\/li>\n\n<li>n\u00f8dvendige dokumenter<\/li>\n\n<li>Se n\u00e6rmere p\u00e5 MDS 300A\u20131200A-serien, n\u00e5r<\/li>\n<\/ul>\n\n\n<p class=\"wp-block-paragraph\">Projektkravet falder ind under en af de offentliggjorte kategorier:<\/p>\n\n\n<p class=\"wp-block-paragraph\">300 \/ 400 \/ 500 \/ 600 \/ 800 \/ 1000 \/ 1200A<\/p>\n\n\n<p class=\"wp-block-paragraph\">Udf\u00f8r derefter den samme verifikation af den n\u00f8jagtige model.<\/p>\n\n\n<p class=\"wp-block-paragraph\">Dette er en metode til at indsn\u00e6vre udvalget af familier, der skal gennemg\u00e5s, og ikke en endelig metode til teknisk udv\u00e6lgelse.<\/p>\n\n<\/div>\n\n\n<div class=\"wp-block-group alignfull is-layout-constrained wp-container-core-group-is-layout-384c61b8 wp-block-group-is-layout-constrained\" style=\"padding-top:48px;padding-right:24px;padding-bottom:48px;padding-left:24px\">\n\n<h2 id=\"neither-family-is-universally-better\" class=\"wp-block-heading\">15. Ingen af familierne er generelt bedre<\/h2>\n\n\n<p class=\"wp-block-paragraph\">Et MDS-modul i 1200A-klassen b\u00f8r ikke beskrives som en bedre version af et modul i 100A-klassen.<\/p>\n\n\n<p class=\"wp-block-paragraph\">Tilsvarende b\u00f8r 30A\u2013250A-serien ikke automatisk beskrives som:<\/p>\n\n\n<ul class=\"wp-block-list\">\n<li>let arbejde<\/li>\n\n<li>billigere<\/li>\n\n<li>mere effektiv<\/li>\n\n<li>nemmere at afk\u00f8le<\/li>\n<\/ul>\n\n\n<p class=\"wp-block-paragraph\">Og 300A\u20131200A-serien b\u00f8r ikke automatisk beskrives som:<\/p>\n\n\n<ul class=\"wp-block-list\">\n<li>til tungt brug<\/li>\n\n<li>mere kraftfuld<\/li>\n\n<li>sikrere<\/li>\n\n<li>mere holdbar<\/li>\n\n<li>bedre egnet til kr\u00e6vende anvendelser<\/li>\n<\/ul>\n\n\n<p class=\"wp-block-paragraph\">Disse konklusioner kr\u00e6ver dokumentation, der endnu ikke er offentliggjort.<\/p>\n\n\n<p class=\"wp-block-paragraph\">Den nyttige skelnen er langt enklere:<\/p>\n\n\n<p class=\"wp-block-paragraph\">De to familier d\u00e6kker forskellige offentliggjorte aktuelle klasser.<\/p>\n\n<\/div>\n\n\n<div class=\"wp-block-group alignfull is-layout-constrained wp-container-core-group-is-layout-384c61b8 wp-block-group-is-layout-constrained\" style=\"padding-top:48px;padding-right:24px;padding-bottom:48px;padding-left:24px\">\n\n<h2 id=\"what-buyers-should-confirm-before-ordering-either-family\" class=\"wp-block-heading\">16. Hvad k\u00f8bere b\u00f8r tjekke, f\u00f8r de bestiller en af de to serier<\/h2>\n\n\n<p class=\"wp-block-paragraph\">Uanset hvilken familie der gennemg\u00e5s, skal du kontrollere:<\/p>\n\n\n<p class=\"wp-block-paragraph\">Nuv\u00e6rende klasse<\/p>\n\n\n<p class=\"wp-block-paragraph\">Hvilken offentliggjort MDS-klasse overvejes?<\/p>\n\n\n<p class=\"wp-block-paragraph\">Sp\u00e6nding<\/p>\n\n\n<p class=\"wp-block-paragraph\">Hvilken specifik sp\u00e6ndingsversion eller hvilket suffiks kr\u00e6ves der?<\/p>\n\n\n<p class=\"wp-block-paragraph\">Ans\u00f8gning<\/p>\n\n\n<p class=\"wp-block-paragraph\">Hvilke belastnings- og driftsforhold g\u00e6lder?<\/p>\n\n\n<p class=\"wp-block-paragraph\">K\u00f8ling<\/p>\n\n\n<p class=\"wp-block-paragraph\">Hvilke varme- og k\u00f8leforanstaltninger er n\u00f8dvendige?<\/p>\n\n\n<p class=\"wp-block-paragraph\">Pr\u00e6cis model<\/p>\n\n\n<p class=\"wp-block-paragraph\">Hvilken fuldst\u00e6ndig modelbetegnelse vil der blive angivet?<\/p>\n\n\n<p class=\"wp-block-paragraph\">Tekniske oplysninger<\/p>\n\n\n<p class=\"wp-block-paragraph\">Er der behov for tegninger, m\u00e5l eller monteringsoplysninger?<\/p>\n\n\n<p class=\"wp-block-paragraph\">Dokumentation<\/p>\n\n\n<p class=\"wp-block-paragraph\">Er der krav om datablade, certifikater, testresultater eller andre tekniske dokumenter?<\/p>\n\n\n<p class=\"wp-block-paragraph\">Antal<\/p>\n\n\n<p class=\"wp-block-paragraph\">Hvilken m\u00e6ngde er der brug for?<\/p>\n\n\n<p class=\"wp-block-paragraph\">Den <a href=\"https:\/\/ritoks.com\/da\/mds-bridge-rectifier-module-selection-guide\/\">Vejledning til valg af MDS-broensrettermodul<\/a> giver mulighed for en mere omfattende udv\u00e6lgelsesproces.<\/p>\n\n<\/div>\n\n\n<div class=\"wp-block-group alignfull has-ast-global-color-4-background-color has-background is-layout-constrained wp-container-core-group-is-layout-8925a0ea wp-block-group-is-layout-constrained\" style=\"padding-top:56px;padding-right:24px;padding-bottom:56px;padding-left:24px\">\n\n<h2 id=\"frequently-asked-questions\" class=\"wp-block-heading\">Ofte stillede sp\u00f8rgsm\u00e5l<\/h2>\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Hvad er den st\u00f8rste forskel mellem de to MDS-familier?<\/summary>\n\n<p class=\"wp-block-paragraph\">Den tydeligste forskel, der er offentliggjort, er d\u00e6kningen af str\u00f8mklasser. Den ene serie omfatter klasser fra 30 A til 250 A, mens den anden serie omfatter klasser fra 300 A til 1200 A.<\/p>\n\n<\/details>\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Findes der en offentliggjort MDS-klasse mellem 250A og 300A?<\/summary>\n\n<p class=\"wp-block-paragraph\">Ikke p\u00e5 disse to aktuelle RITOKS-produktsider. Det beskriver udelukkende den nuv\u00e6rende offentliggjorte produktserie og er ikke en generel udtalelse om hele markedet.<\/p>\n\n<\/details>\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Er 300A\u20131200A-serien bedre?<\/summary>\n\n<p class=\"wp-block-paragraph\">Nej. En h\u00f8jere str\u00f8mklasse er ikke ensbetydende med bedre effektivitet, sikkerhed, k\u00f8ling eller egnethed.<\/p>\n\n<\/details>\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Kan jeg v\u00e6lge en model direkte fra tabellen over belastningsstr\u00f8m?<\/summary>\n\n<p class=\"wp-block-paragraph\">Tabellerne indeholder oplysninger om leverand\u00f8rer. De b\u00f8r ikke omdannes til en universel formel eller en regel for automatisk udv\u00e6lgelse.<\/p>\n\n<\/details>\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Er de angivne st\u00f8rrelser p\u00e5 k\u00f8lepladerne modulm\u00e5l?<\/summary>\n\n<p class=\"wp-block-paragraph\">Nej. Det er leverand\u00f8rens angivne dimensioner for k\u00f8lepladen, og de b\u00f8r ikke fortolkes som dimensionerne for modulpakken.<\/p>\n\n<\/details>\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Er sp\u00e6ndingsindstillingerne de samme for begge serier?<\/summary>\n\n<p class=\"wp-block-paragraph\">De foreliggende oplysninger giver ikke grundlag for en pr\u00e6cis sammenligning af sp\u00e6ndingen. Kontroller, hvilken sp\u00e6ndingsversion der g\u00e6lder for den valgte model.<\/p>\n\n<\/details>\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Findes der m\u00e5l og terminaltegninger?<\/summary>\n\n<p class=\"wp-block-paragraph\">Der er i \u00f8jeblikket ikke offentliggjort fuldst\u00e6ndige, verificerede mekaniske oplysninger p\u00e5 modelniveau p\u00e5 de to produktsider. Anmod om den n\u00f8dvendige tegning inden den mekaniske integration.<\/p>\n\n<\/details>\n\n<\/div>\n\n\n<div class=\"wp-block-group alignfull has-ast-global-color-5-background-color has-background is-layout-constrained wp-container-core-group-is-layout-8925a0ea wp-block-group-is-layout-constrained\" style=\"padding-top:56px;padding-right:24px;padding-bottom:56px;padding-left:24px\">\n\n<h2 id=\"compare-the-exact-mds-family-before-your-rfq\" class=\"wp-block-heading\">Sammenlign den n\u00f8jagtige MDS-serie, inden du indsender din foresp\u00f8rgsel<\/h2>\n\n\n<p class=\"wp-block-paragraph\">Start med de offentliggjorte aktuelle hold:<\/p>\n\n\n<ul class=\"wp-block-list\">\n<li><strong>MDS 30A\u2013250A<\/strong> \u2192 30 \/ 60 \/ 75 \/ 100 \/ 150 \/ 200 \/ 250A<\/li>\n\n<li><strong>MDS 300A\u20131200A<\/strong> \u2192 300 \/ 400 \/ 500 \/ 600 \/ 800 \/ 1000 \/ 1200A<\/li>\n<\/ul>\n\n\n<p class=\"wp-block-paragraph\">Kontroller derefter:<\/p>\n\n\n<p class=\"wp-block-paragraph\">nuv\u00e6rende klasse \u2192 sp\u00e6ndingsversion \u2192 anvendelse\/belastning \u2192 k\u00f8ling \u2192 pr\u00e6cis model \u2192 dokumentation<\/p>\n\n\n<p class=\"wp-block-paragraph\">inden du bestiller.<\/p>\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/ritoks.com\/da\/product-category\/power-semiconductor-modules\/\">Se moduler til effekt-halvledere \u2192<\/a><\/li>\n\n<li><a href=\"https:\/\/ritoks.com\/da\/product-category\/power-semiconductor-modules\/bridge-rectifier-modules\/\">Se bro-ensrettermoduler \u2192<\/a><\/li>\n\n<li><a href=\"https:\/\/ritoks.com\/da\/mds-bridge-rectifier-module-selection-guide\/\">L\u00e6s vejledningen til valg af MDS-bro-ensrettermoduler \u2192<\/a><\/li>\n\n<li><a href=\"https:\/\/ritoks.com\/da\/products\/mds-three-phase-bridge-rectifier-30a-250a\/\">Se MDS 30A\u2013250A-moduler \u2192<\/a><\/li>\n\n<li><a href=\"https:\/\/ritoks.com\/da\/products\/mds-high-current-bridge-rectifier-300a-1200a\/\">Se MDS 300A\u20131200A-moduler \u2192<\/a><\/li>\n<\/ul>\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-text-color has-background wp-element-button\" href=\"https:\/\/ritoks.com\/da\/contact-us\/\" style=\"border-radius:6px;color:#ffffff;background-color:#1d5fbf\">Kontakt RITOKS \u2192 Bekr\u00e6ft din MDS-model<\/a><\/div>\n<\/div>\n\n<\/div>","protected":false},"excerpt":{"rendered":"<p>RITOKS currently publishes two MDS three-phase bridge rectifier module families covering different current-class ranges: MDS 30A\u2013250A MDS 300A\u20131200A Both are [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ritoks_resource_detail_renderer":null,"ritoks_resource_product_cat_term_id":0,"footnotes":""},"categories":[66],"tags":[],"class_list":["post-762","post","type-post","status-publish","format-standard","hentry","category-power-semiconductors"],"acf":[],"spectra_blocks_featured_image_url":null,"spectra_blocks_author_info":{"display_name":"RITOKS","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/6d7d0fc73468198f994ab13ef6eb6558c53b6ed1ad86364d5165efe8bdf8eb4a?s=96&d=mm&r=g","author_link":"https:\/\/ritoks.com\/da\/author\/dazzlingwqbgmail-com\/","description":""},"_links":{"self":[{"href":"https:\/\/ritoks.com\/da\/wp-json\/wp\/v2\/posts\/762","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ritoks.com\/da\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ritoks.com\/da\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ritoks.com\/da\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/ritoks.com\/da\/wp-json\/wp\/v2\/comments?post=762"}],"version-history":[{"count":3,"href":"https:\/\/ritoks.com\/da\/wp-json\/wp\/v2\/posts\/762\/revisions"}],"predecessor-version":[{"id":2179,"href":"https:\/\/ritoks.com\/da\/wp-json\/wp\/v2\/posts\/762\/revisions\/2179"}],"wp:attachment":[{"href":"https:\/\/ritoks.com\/da\/wp-json\/wp\/v2\/media?parent=762"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ritoks.com\/da\/wp-json\/wp\/v2\/categories?post=762"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ritoks.com\/da\/wp-json\/wp\/v2\/tags?post=762"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}