
DC Power Protection · RTX-HA
RTX-HA IP65 PV Combiner Boxes, 1-6 Inputs
IP65 PV combiner boxes with clear PC covers and DIN rail, in DC500V and DC1000V versions for 1–6 strings. Before selection, confirm the number of strings, system voltage and string current, and required fuses, isolator and SPD.
Tensión del sistemaDC500V / DC1000V
Inputs / outputs1–6 in, 1–4 out
ProtecciónIP65
AnexoPlastic, PC cover
Descripción general del producto
RTX-HA combiner boxes gather PV strings into one or more outputs for the inverter. The enclosure is plastic with a transparent PC cover and an internal DIN rail. The internal fit-out of fuses, isolator and SPD differs by version; confirm the component list and ratings before ordering.
Características principales
- DC500V and DC1000V versions
- 12 input/output topologies from 1/1 to 6/3
- IP65 plastic enclosure with PC cover
- DIN-rail fit-out by configuration
Modelos y configuraciones disponibles
Use these RITOKS configuration references for enquiry; confirm the exact specification before ordering.
| Referencia de RITOKS | Datos de entrada | Resultados | Voltage versions |
|---|---|---|---|
| RTX-HA-11 | 1 | 1 | DC500V / DC1000V |
| RTX-HA-21 | 2 | 1 | DC500V / DC1000V |
| RTX-HA-22 | 2 | 2 | DC500V / DC1000V |
| RTX-HA-31 | 3 | 1 | DC500V / DC1000V |
| RTX-HA-33 | 3 | 3 | DC500V / DC1000V |
| RTX-HA-41 | 4 | 1 | DC500V / DC1000V |
| RTX-HA-42 | 4 | 2 | DC500V / DC1000V |
| RTX-HA-44 | 4 | 4 | DC500V / DC1000V |
| RTX-HA-51 | 5 | 1 | DC500V / DC1000V |
| RTX-HA-61 | 6 | 1 | DC500V / DC1000V |
| RTX-HA-62 | 6 | 2 | DC500V / DC1000V |
| RTX-HA-63 | 6 | 3 | DC500V / DC1000V |
Especificaciones técnicas
| Tipo de producto | PV DC combiner box |
|---|---|
| Tensión del sistema | DC500V or DC1000V |
| Topologías | 1/1, 2/1, 2/2, 3/1, 3/3, 4/1, 4/2, 4/4, 5/1, 6/1, 6/2, 6/3 |
| Anexo | Plastic, transparent PC cover |
| Protección | IP65 |
| Internal mounting | Riel DIN |
| Component list and ratings | Confirm with RITOKS before ordering |
Aplicaciones
AI-generated conceptual application context. Confirm equipment fit, installation conditions and circuit requirements for the selected configuration.

Residential rooftop PV
Combine two to four strings on a wall beside the inverter.
Commercial rooftop arrays
Use multi-output versions for multi-MPPT inverters.
Off-grid solar systems
Group strings ahead of charge controllers in DC500V systems.
Datos que hay que confirmar para la selección
- Number of strings and inverter MPPT inputs
- System voltage and string current
- Required fuses, isolator and SPD
- Cable glands, connectors and quantity
Preguntas frecuentes
Which components are inside?
Fit-out differs by version. Request the component list with ratings for your configuration.
Can the box be installed outdoors?
The enclosure is IP65. Also check UV exposure, ambient temperature and gland sealing on site.
Solicitar un presupuesto
Send these details so the team can review the configuration and prepare a quotation:
- Number of strings and inverter MPPT inputs
- System voltage and string current
- Required fuses, isolator and SPD
- Cable glands, connectors and quantity
- Application and destination country

