{"id":699,"date":"2026-09-05T16:51:06","date_gmt":"2026-09-05T16:51:06","guid":{"rendered":"https:\/\/ritoks.com\/?p=699"},"modified":"2026-09-20T06:54:43","modified_gmt":"2026-09-20T06:54:43","slug":"b-curve-vs-c-curve-vs-d-curve-mcb","status":"publish","type":"post","link":"https:\/\/ritoks.com\/es\/b-curve-vs-c-curve-vs-d-curve-mcb\/","title":{"rendered":"Disyuntores autom\u00e1ticos de curva B, curva C y curva D: \u00bfen qu\u00e9 se diferencian?"},"content":{"rendered":"<div class=\"wp-block-group alignfull has-ast-global-color-5-color has-ast-global-color-2-background-color has-text-color has-background is-layout-constrained wp-container-core-group-is-layout-a2d0cf3a wp-block-group-is-layout-constrained\" style=\"padding-top:64px;padding-right:24px;padding-bottom:64px;padding-left:24px\">\n\n\n<h1 class=\"wp-block-heading\">Disyuntores autom\u00e1ticos de curva B, curva C y curva D: \u00bfen qu\u00e9 se diferencian?<\/h1>\n\n\n\n<figure data-spectra-id=\"spectra-48d6897c-1760-4f9f-9967-dc900ce0c7a7\" class=\"wp-block-image aligncenter size-full has-custom-border\" ><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-family-hero.png\" alt=\"Gamas representativas de interruptores autom\u00e1ticos de corriente alterna de tama\u00f1o miniatura en un taller el\u00e9ctrico industrial\" class=\"wp-image-701\"  width=\"1672\" height=\"941\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-family-hero.png 1672w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-family-hero-600x338.png 600w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-family-hero-300x169.png 300w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-family-hero-1024x576.png 1024w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-family-hero-768x432.png 768w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-family-hero-1536x864.png 1536w\" sizes=\"auto, (max-width: 1672px) 100vw, 1672px\" \/><figcaption class=\"wp-element-caption\">Formatos representativos de disyuntores de corriente alterna (AC MCB) en un entorno el\u00e9ctrico industrial.<\/figcaption><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Las curvas B, C y D son distintas caracter\u00edsticas de disparo que se utilizan con <a href=\"https:\/\/ritoks.com\/es\/product-category\/ac-power-protection\/miniature-circuit-breakers\/\">disyuntores miniatura (MCB)<\/a>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Las letras no indican la intensidad nominal, la capacidad de corte ni el n\u00famero de polos. En cambio, sirven para describir c\u00f3mo responde el disyuntor a corrientes elevadas de corta duraci\u00f3n en su zona de disparo instant\u00e1neo.<\/p>\n\n\n<\/div>\n\n\n\n<div class=\"wp-block-group alignfull is-layout-constrained wp-container-core-group-is-layout-105ba9aa wp-block-group-is-layout-constrained\" style=\"padding-top:64px;padding-right:24px;padding-bottom:64px;padding-left:24px\">\n\n\n<p class=\"wp-block-paragraph\">Los datos t\u00e9cnicos del fabricante suelen indicar los siguientes rangos de caracter\u00edsticas:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Curva B: aproximadamente 3-5 \u00d7 In<\/li>\n<li>Curva C: aproximadamente 5\u201310 \u00d7 In<\/li>\n<li>Curva D: aproximadamente 10\u201320 \u00d7 In<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">En este caso, \u00abIn\u00bb representa la corriente nominal del interruptor para la caracter\u00edstica a la que se hace referencia. <a href=\"https:\/\/www.eaton.com\/content\/dam\/eaton\/support\/apac-support-assets\/japan-cps-assets\/products\/2023promotions_lp\/sccr2024_pdf01.pdf\" target=\"_blank\" rel=\"noopener\">Documentaci\u00f3n t\u00e9cnica de Eaton<\/a> publica estos mismos rangos de respuesta de disparo por cortocircuito B, C y D para sus gamas de interruptores autom\u00e1ticos miniatura.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La diferencia pr\u00e1ctica radica en que las tres curvas admiten distintos niveles de corriente de corta duraci\u00f3n antes de alcanzar la zona de disparo instant\u00e1neo.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Eso no significa que una curva sea, en todos los casos, mejor que otra.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La curva requerida debe basarse en el dise\u00f1o el\u00e9ctrico real, las condiciones de corriente de arranque previstas y la documentaci\u00f3n del interruptor que se vaya a seleccionar.<\/p>\n\n\n\n<h2 id=\"in-this-guide\" class=\"wp-block-heading\">En esta gu\u00eda<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"#quick-comparison\">Comparaci\u00f3n r\u00e1pida: curva B, curva C y curva D<\/a><\/li>\n<li><a href=\"#mcb-trip-curve\">\u00bfQu\u00e9 es una curva de disparo de un disyuntor?<\/a><\/li>\n<li><a href=\"#b-curve\">\u00bfQu\u00e9 es un disyuntor de curva B?<\/a><\/li>\n<li><a href=\"#c-curve\">\u00bfQu\u00e9 es un disyuntor de curva C?<\/a><\/li>\n<li><a href=\"#d-curve\">\u00bfQu\u00e9 es un disyuntor de curva D?<\/a><\/li>\n<li><a href=\"#curve-availability\">Disponibilidad actual de la curva RITOKS<\/a><\/li>\n<li><a href=\"#selection-process\">C\u00f3mo elegir entre las opciones de curvas B, C y D<\/a><\/li>\n<li><a href=\"#frequently-asked-questions\">Preguntas frecuentes<\/a><\/li>\n<\/ul>\n\n\n\n<h2 id=\"quick-comparison\" class=\"wp-block-heading\">Comparaci\u00f3n r\u00e1pida: curva B, curva C y curva D<\/h2>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table><thead><tr><th>Caracter\u00edstica<\/th><th>Regi\u00f3n com\u00fan de disparo instant\u00e1neo<\/th><th>Contexto general sobre la corriente de arranque<\/th><\/tr><\/thead><tbody><tr><td>Curva B<\/td><td>3\u20135 \u00d7 pulg.<\/td><td>Se espera una corriente de arranque menor<\/td><\/tr><tr><td>Curva C<\/td><td>5\u201310 \u00d7 pulgadas<\/td><td>Se prev\u00e9 una corriente de arranque moderada<\/td><\/tr><tr><td>Curva D<\/td><td>10\u201320 \u00d7 pulgadas<\/td><td>Se prev\u00e9 un pico de corriente de arranque m\u00e1s elevado<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Estos rangos describen las caracter\u00edsticas generales documentadas por los principales fabricantes de MCB. No deben considerarse como una curva tiempo-corriente RITOKS espec\u00edfica de un modelo, a menos que la documentaci\u00f3n exacta del producto RITOKS as\u00ed lo confirme.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.eaton.com\/content\/dam\/eaton\/products\/electrical-circuit-protection\/industrial-miniature-circuit-breakers\/Industrial-breakers-catalog-ca08100005e.pdf\" target=\"_blank\" rel=\"noopener\">Gu\u00eda sobre los interruptores autom\u00e1ticos industriales en miniatura de Eaton<\/a>, por ejemplo, describe la caracter\u00edstica B para situaciones con corrientes de arranque bajas, la C para situaciones con corrientes de arranque medias y la D para situaciones con corrientes de arranque elevadas. En su gu\u00eda de aplicaci\u00f3n se ofrecen ejemplos como los peque\u00f1os transformadores y los equipos de control para la caracter\u00edstica C, y los equipos con corrientes de arranque m\u00e1s elevadas, como motores, transformadores y fuentes de alimentaci\u00f3n, para la caracter\u00edstica D. Se trata de ejemplos t\u00edpicos, no de reglas universales para la selecci\u00f3n de cargas.<\/p>\n\n\n\n<figure data-spectra-id=\"spectra-02905441-35ab-45ae-8530-b3ecfff11240\" class=\"wp-block-image aligncenter size-full has-custom-border\" ><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/b-c-d-curve-options-comparison.png\" alt=\"Comparaci\u00f3n conceptual de las opciones de MCB con curvas B, C y D\" class=\"wp-image-702\"  width=\"1672\" height=\"941\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/b-c-d-curve-options-comparison.png 1672w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/b-c-d-curve-options-comparison-600x338.png 600w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/b-c-d-curve-options-comparison-300x169.png 300w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/b-c-d-curve-options-comparison-1024x576.png 1024w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/b-c-d-curve-options-comparison-768x432.png 768w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/b-c-d-curve-options-comparison-1536x864.png 1536w\" sizes=\"auto, (max-width: 1672px) 100vw, 1672px\" \/><figcaption class=\"wp-element-caption\">Comparaci\u00f3n conceptual de las curvas B, C y D. La designaci\u00f3n de la curva es uno de los par\u00e1metros de selecci\u00f3n y es necesario verificar la documentaci\u00f3n exacta del modelo.<\/figcaption><\/figure>\n\n\n\n<h2 id=\"mcb-trip-curve\" class=\"wp-block-heading\">\u00bfQu\u00e9 es una curva de disparo de un disyuntor?<\/h2>\n\n\n<p class=\"wp-block-paragraph\">Un disyuntor autom\u00e1tico protege un circuito contra situaciones de sobrecorriente, pero su respuesta no depende \u00fanicamente de su intensidad nominal.<\/p>\n<p class=\"wp-block-paragraph\">Una caracter\u00edstica del viaje describe parte de esa respuesta.<\/p>\n<p class=\"wp-block-paragraph\">En el caso de los interruptores autom\u00e1ticos de corriente magn\u00e9tica (MCB) de curvas B, C y D, una de las diferencias m\u00e1s evidentes es la zona de disparo instant\u00e1neo o magn\u00e9tico.<\/p>\n<p class=\"wp-block-paragraph\">Consideremos dos interruptores con la misma intensidad nominal.<\/p>\n<p class=\"wp-block-paragraph\">Un disyuntor de curva B y un disyuntor de curva D pueden tener la misma corriente nominal en condiciones normales, pero sus rangos de disparo instant\u00e1neo pueden diferir considerablemente.<\/p>\n<p class=\"wp-block-paragraph\">Por eso:<\/p>\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p class=\"wp-block-paragraph\">\u201cLas denominaciones \u201dcurva B de 32 A\u201c y \u201dcurva D de 32 A\u00bb no describen un comportamiento de protecci\u00f3n id\u00e9ntico por el mero hecho de que ambos interruptores tengan una intensidad nominal de 32 A.<\/p><\/blockquote>\n\n\n<p class=\"wp-block-paragraph\">Por lo tanto, la curva es otro par\u00e1metro de selecci\u00f3n, junto con:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>corriente nominal<\/li>\n<li>tensi\u00f3n<\/li>\n<li>postes<\/li>\n<li>capacidad de frenado<\/li>\n<li>formato de montaje<\/li>\n<li>modelo exacto<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Para obtener m\u00e1s informaci\u00f3n sobre el proceso de selecci\u00f3n en general, consulta <a href=\"https:\/\/ritoks.com\/es\/ac-mcb-selection-guide\/\">Gu\u00eda de selecci\u00f3n de interruptores autom\u00e1ticos de corriente alterna (MCB): corriente, polos, curva de disparo y capacidad de corte<\/a>.<\/p>\n\n\n\n<h2 id=\"b-curve\" class=\"wp-block-heading\">\u00bfQu\u00e9 es un disyuntor de curva B?<\/h2>\n\n\n<p class=\"wp-block-paragraph\">Una caracter\u00edstica A-B suele utilizar un rango de disparo instant\u00e1neo de aproximadamente entre 3 y 5 veces la corriente nominal.<\/p>\n<p class=\"wp-block-paragraph\">En t\u00e9rminos generales, esto significa que se alcanza la regi\u00f3n magn\u00e9tica instant\u00e1nea con un m\u00faltiplo de la corriente nominal inferior al que se requiere con las caracter\u00edsticas C o D.<\/p>\n<p class=\"wp-block-paragraph\">Las recomendaciones del fabricante suelen recomendar el uso de la clase B en aplicaciones en las que se espera una corriente de arranque relativamente baja.<\/p>\n<p class=\"wp-block-paragraph\">Sin embargo, eso no deber\u00eda convertirse en una regla del tipo:<\/p>\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p class=\"wp-block-paragraph\">\u201cTodos los circuitos de iluminaci\u00f3n deben utilizar la curva B\u201d.\u201d<\/p><\/blockquote>\n<p class=\"wp-block-paragraph\">La selecci\u00f3n concreta depende del circuito, la corriente de arranque prevista, las condiciones de fallo y los requisitos de dise\u00f1o aplicables.<\/p>\n\n\n<h3 class=\"wp-block-heading\">Disponibilidad actual de la curva B de RITOKS<\/h3>\n\n\n<p class=\"wp-block-paragraph\">Publicado recientemente <a href=\"https:\/\/ritoks.com\/es\/product-category\/ac-power-protection\/\">Datos del disyuntor RITOKS AC MCB<\/a> confirma la disponibilidad de la curva B en:<\/p>\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/ritoks.com\/es\/products\/miniature-circuit-breaker-63a-10ka\/\">RTSXD01<\/a> \u2014 B \/ C \/ D<\/li>\n<li>RTSXD03 \u2014 B \/ C<\/li>\n<li><a href=\"https:\/\/ritoks.com\/es\/products\/1pn-miniature-circuit-breaker-32a-6ka\/\">RTSXD02<\/a> \u2014 B \/ C<\/li>\n<li><a href=\"https:\/\/ritoks.com\/es\/products\/miniature-circuit-breaker-63a-10ka-pro\/\">RTSXD04<\/a> \u2014 B \/ C \/ D<\/li>\n<li><a href=\"https:\/\/ritoks.com\/es\/products\/m60-ac-miniature-circuit-breaker-6-63a\/\">RTS-ACM60<\/a> \u2014 B \/ C<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">La curva de viaje del RTS-AC47 a\u00fan no est\u00e1 confirmada.<\/p>\n<p class=\"wp-block-paragraph\">Estos datos solo confirman la disponibilidad. No establecen el comportamiento exacto de la relaci\u00f3n tiempo-corriente espec\u00edfico de cada modelo m\u00e1s all\u00e1 de lo indicado en la curva publicada.<\/p>\n\n\n<h2 id=\"c-curve\" class=\"wp-block-heading\">\u00bfQu\u00e9 es un disyuntor de curva C?<\/h2>\n\n\n<p class=\"wp-block-paragraph\">Una caracter\u00edstica de tipo C suele utilizar un rango de disparo instant\u00e1neo de aproximadamente entre 5 y 10 veces la corriente nominal.<\/p>\n<p class=\"wp-block-paragraph\">En comparaci\u00f3n con la caracter\u00edstica B, esto permite un m\u00faltiplo de corriente de corta duraci\u00f3n mayor antes de entrar en la zona de disparo instant\u00e1neo.<\/p>\n<p class=\"wp-block-paragraph\">Eaton describe la caracter\u00edstica C como adecuada para situaciones con una corriente de arranque media y ofrece ejemplos como transformadores peque\u00f1os, iluminaci\u00f3n, dispositivos piloto, circuitos de control y bobinas. Se trata de un contexto general \u00fatil, pero eso no significa que todas y cada una de esas aplicaciones requieran autom\u00e1ticamente una curva C.<\/p>\n\n\n<h3 class=\"wp-block-heading\">Disponibilidad actual de la curva C de RITOKS<\/h3>\n\n<p class=\"wp-block-paragraph\">La curva C es, en la actualidad, la m\u00e1s ampliamente confirmada entre las familias de MCB de RITOKS AC publicadas:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>RTSXD01 \u2014 B \/ C \/ D<\/li>\n<li>RTSXD03 \u2014 B \/ C<\/li>\n<li>RTSXD02 \u2014 B \/ C<\/li>\n<li>RTSXD04 \u2014 B \/ C \/ D<\/li>\n<li>RTS-ACM60 \u2014 B \/ C<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">Una vez m\u00e1s, el RTS-AC47 no tiene actualmente ninguna designaci\u00f3n de curva confirmada en la p\u00e1gina web.<\/p>\n\n\n<h2 id=\"d-curve\" class=\"wp-block-heading\">\u00bfQu\u00e9 es un disyuntor de curva D?<\/h2>\n\n\n<p class=\"wp-block-paragraph\">Una caracter\u00edstica \u00abD\u00bb suele utilizar un rango de disparo instant\u00e1neo de aproximadamente entre 10 y 20 veces la corriente nominal.<\/p>\n<p class=\"wp-block-paragraph\">Esta es la m\u00e1s alta de las tres regiones instant\u00e1neas habituales que se analizan aqu\u00ed.<\/p>\n<p class=\"wp-block-paragraph\">Las directrices de los fabricantes suelen asociar las caracter\u00edsticas \u00abD\u00bb con equipos que presentan una corriente de arranque elevada. Eaton cita como ejemplos t\u00edpicos los motores, los transformadores, las fuentes de alimentaci\u00f3n y otros sistemas altamente inductivos.<\/p>\n<p class=\"wp-block-paragraph\">La palabra \u00abt\u00edpico\u00bb es importante.<\/p>\n<p class=\"wp-block-paragraph\">No ser\u00eda acertado concluir que:<\/p>\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p class=\"wp-block-paragraph\">\u201cMotor = curva en D\u201d.\u201d<\/p><\/blockquote>\n<p class=\"wp-block-paragraph\">Un circuito de motor puede incluir numerosas variables, entre las que se encuentran las caracter\u00edsticas de arranque y el dise\u00f1o general de la protecci\u00f3n. Por lo tanto, la curva del interruptor debe seleccionarse en funci\u00f3n de requisitos t\u00e9cnicos contrastados y no bas\u00e1ndose \u00fanicamente en la denominaci\u00f3n del equipo.<\/p>\n\n\n<h3 class=\"wp-block-heading\">Disponibilidad actual de la curva D de RITOKS<\/h3>\n\n<p class=\"wp-block-paragraph\">Los datos actuales publicados por RITOKS confirman la curva D en:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>RTSXD01<\/li>\n<li>RTSXD04<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">Las dem\u00e1s familias de interruptores autom\u00e1ticos de corriente continua (AC MCB) publicadas actualmente no indican en sus p\u00e1ginas de producto si disponen de la curva D.<\/p>\n\n\n<h2 id=\"why-curves-differ\" class=\"wp-block-heading\">\u00bfPor qu\u00e9 las curvas utilizan distintas regiones instant\u00e1neas?<\/h2>\n\n\n<p class=\"wp-block-paragraph\">Los equipos el\u00e9ctricos pueden consumir una corriente superior a su nivel de funcionamiento estable durante un breve periodo de tiempo.<\/p>\n<p class=\"wp-block-paragraph\">Esto puede ocurrir durante operaciones como la puesta en tensi\u00f3n o la puesta en marcha.<\/p>\n<p class=\"wp-block-paragraph\">Si el rango de disparo instant\u00e1neo del interruptor es demasiado bajo para la corriente de corta duraci\u00f3n prevista, el interruptor podr\u00eda dispararse aunque el suceso formara parte del arranque normal del equipo.<\/p>\n<p class=\"wp-block-paragraph\">Por el contrario, el mero hecho de elegir una curva con una regi\u00f3n instant\u00e1nea mayor no significa autom\u00e1ticamente que sea mejor.<\/p>\n<p class=\"wp-block-paragraph\">El sistema de protecci\u00f3n a\u00fan debe responder de forma adecuada a las aver\u00edas reales.<\/p>\n<p class=\"wp-block-paragraph\">Por eso, las caracter\u00edsticas B, C y D deben entenderse como diferentes caracter\u00edsticas de protecci\u00f3n, y no como grados de calidad.<\/p>\n<p class=\"wp-block-paragraph\">D no es una versi\u00f3n \u201cpremium\u201d de C, y C no es una \u201cactualizaci\u00f3n\u201d de B.<\/p>\n\n\n<h2 id=\"same-rated-current\" class=\"wp-block-heading\">B frente a C frente a D con la misma corriente nominal<\/h2>\n\n\n<p class=\"wp-block-paragraph\">Imagina tres interruptores autom\u00e1ticos que tienen todos la misma corriente nominal, In.<\/p>\n<p class=\"wp-block-paragraph\">Utilizando los rangos de caracter\u00edsticas habituales:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>B alcanza su regi\u00f3n instant\u00e1nea en torno a 3\u20135 \u00d7 In<\/li>\n<li>C entre 5 y 10 \u00d7 In<\/li>\n<li>D entre 10 y 20 veces In<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">A modo de ejemplo, si In = 10 A, esos m\u00faltiplos se corresponden matem\u00e1ticamente con:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>B: aproximadamente entre 30 y 50 A<\/li>\n<li>C: aproximadamente entre 50 y 100 A<\/li>\n<li>D: aproximadamente entre 100 y 200 A<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">Este ejemplo aritm\u00e9tico solo ilustra el significado de los m\u00faltiplos. No constituye una recomendaci\u00f3n para la selecci\u00f3n de productos y no debe interpretarse como el comportamiento operativo exacto de un interruptor RITOKS concreto.<\/p>\n<p class=\"wp-block-paragraph\">El comportamiento real del disyuntor debe verificarse compar\u00e1ndolo con la documentaci\u00f3n exacta del fabricante sobre tiempo-corriente y con los requisitos aplicables al producto.<\/p>\n\n\n<h2 id=\"curve-availability\" class=\"wp-block-heading\">Resumen de la disponibilidad actual de la curva RITOKS<\/h2>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table><thead><tr><th>Modelo RITOKS<\/th><th>B<\/th><th>C<\/th><th>D<\/th><th>Datos actuales<\/th><\/tr><\/thead><tbody><tr><td>RTSXD01<\/td><td>S\u00ed<\/td><td>S\u00ed<\/td><td>S\u00ed<\/td><td>Disponibilidad publicada<\/td><\/tr><tr><td>RTSXD03<\/td><td>S\u00ed<\/td><td>S\u00ed<\/td><td>\u2014<\/td><td>Disponibilidad publicada<\/td><\/tr><tr><td>RTSXD02<\/td><td>S\u00ed<\/td><td>S\u00ed<\/td><td>\u2014<\/td><td>Disponibilidad publicada<\/td><\/tr><tr><td>RTSXD04<\/td><td>S\u00ed<\/td><td>S\u00ed<\/td><td>S\u00ed<\/td><td>Disponibilidad publicada<\/td><\/tr><tr><td>RTS-ACM60<\/td><td>S\u00ed<\/td><td>S\u00ed<\/td><td>\u2014<\/td><td>Disponibilidad publicada<\/td><\/tr><tr><td>RTS-AC47<\/td><td>Sin confirmar<\/td><td>Sin confirmar<\/td><td>Sin confirmar<\/td><td>Curva no confirmada<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n<p class=\"wp-block-paragraph\">Esta tabla debe utilizarse \u00fanicamente para la preselecci\u00f3n de familias de productos.<\/p>\n<p class=\"wp-block-paragraph\">Esto no significa que las curvas de los fabricantes externos mencionadas anteriormente sean las curvas exactas de tiempo-corriente probadas de estos modelos de RITOKS.<\/p>\n\n\n<figure data-spectra-id=\"spectra-3301ab3a-3f04-4a81-93ed-7a99c0278ac0\" class=\"wp-block-image aligncenter size-full has-custom-border\" ><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-pole-formats-panel.png\" alt=\"Diferentes formatos de polos de los interruptores autom\u00e1ticos miniatura de CA en un cuadro de distribuci\u00f3n industrial\" class=\"wp-image-703\"  width=\"1672\" height=\"941\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-pole-formats-panel.png 1672w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-pole-formats-panel-600x338.png 600w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-pole-formats-panel-300x169.png 300w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-pole-formats-panel-1024x576.png 1024w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-pole-formats-panel-768x432.png 768w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-pole-formats-panel-1536x864.png 1536w\" sizes=\"auto, (max-width: 1672px) 100vw, 1672px\" \/><figcaption class=\"wp-element-caption\">Formatos ilustrativos de productos MCB de CA; la disponibilidad de curvas y los valores nominales el\u00e9ctricos deben confirmarse para el modelo concreto.<\/figcaption><\/figure>\n\n\n\n<h2 id=\"selection-process\" class=\"wp-block-heading\">C\u00f3mo elegir entre las opciones de curvas B, C y D<\/h2>\n\n\n<p class=\"wp-block-paragraph\">El proceso pr\u00e1ctico de selecci\u00f3n de proveedores comienza por la caracter\u00edstica requerida, no por una suposici\u00f3n basada en el nombre del producto.<\/p>\n\n<h3 class=\"wp-block-heading\">1. Confirmar los requisitos de carga y corriente de arranque<\/h3>\n<p class=\"wp-block-paragraph\">Averigua si la documentaci\u00f3n del proyecto ya define:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>corriente de arranque prevista<\/li>\n<li>comportamiento de corriente de arranque<\/li>\n<li>curva requerida<\/li>\n<li>otras restricciones de protecci\u00f3n<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">Si ya se ha especificado la curva requerida, util\u00edzala como punto de partida.<\/p>\n\n<h3 class=\"wp-block-heading\">2. Comprueba la corriente nominal<\/h3>\n<p class=\"wp-block-paragraph\">La curva de disparo y la corriente nominal son par\u00e1metros independientes.<\/p>\n<p class=\"wp-block-paragraph\">Por ejemplo:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>C16<\/li>\n<li>C32<\/li>\n<li>C63<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">Todos comparten la designaci\u00f3n \u00abC\u00bb, pero tienen intensidades nominales diferentes.<\/p>\n<p class=\"wp-block-paragraph\">No selecciones primero la curva e ignores la corriente nominal del interruptor.<\/p>\n\n<h3 class=\"wp-block-heading\">3. Confirmar la capacidad de frenado<\/h3>\n<p class=\"wp-block-paragraph\">Curva de recorrido y <a href=\"https:\/\/ritoks.com\/es\/6ka-vs-10ka-mcb-breaking-capacity\/\">Capacidad de corte de un MCB de 6 kA frente a uno de 10 kA<\/a> tambi\u00e9n son par\u00e1metros diferentes.<\/p>\n<p class=\"wp-block-paragraph\">La designaci\u00f3n A, B, C o D no indica si el disyuntor cuenta con:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>6 kA<\/li>\n<li>10 kA<\/li>\n<li>o otro valor de capacidad de rotura<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">Esa caracter\u00edstica debe comprobarse por separado en el producto concreto.<\/p>\n\n<h3 class=\"wp-block-heading\">4. Confirma la configuraci\u00f3n de los polos<\/h3>\n<p class=\"wp-block-paragraph\">Una curva B\/C\/D obligatoria solo puede resultar \u00fatil si la misma familia de productos tambi\u00e9n ofrece lo siguiente:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>1P<\/li>\n<li>1P+N<\/li>\n<li>2P<\/li>\n<li>3P<\/li>\n<li>3P+N<\/li>\n<li>4P<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">configuraci\u00f3n.<\/p>\n\n<h3 class=\"wp-block-heading\">5. Comprueba la documentaci\u00f3n exacta del producto<\/h3>\n<p class=\"wp-block-paragraph\">El \u00faltimo paso consiste en comprobar el propio disyuntor seleccionado.<\/p>\n<p class=\"wp-block-paragraph\">No des nada por sentado:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>todas las curvas B se comportan de la misma manera en todos los fabricantes<\/li>\n<li>Todas las curvas C tienen tolerancias tiempo-corriente id\u00e9nticas.<\/li>\n<li>Todas las curvas D son adecuadas para cualquier carga con pico de corriente elevado.<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">La designaci\u00f3n de la curva forma parte de la especificaci\u00f3n completa del producto.<\/p>\n\n\n<h2 id=\"common-mistakes\" class=\"wp-block-heading\">Errores habituales en la selecci\u00f3n de curvas B\/C\/D<\/h2>\n\n\n<h3 class=\"wp-block-heading\">Considerar B, C y D como niveles de calidad<\/h3>\n<p class=\"wp-block-paragraph\">Se trata de caracter\u00edsticas diferentes de los viajes, no de \u201cb\u00e1sico\u201d, \u201cmejor\u201d y \u201cel mejor\u201d.\u201d<\/p>\n\n<h3 class=\"wp-block-heading\">Selecci\u00f3n bas\u00e1ndose \u00fanicamente en el nombre de la carga<\/h3>\n<p class=\"wp-block-paragraph\">Afirmaciones como \u201cel motor implica una curva en D\u201d son demasiado generales.<\/p>\n<p class=\"wp-block-paragraph\">Es necesario tener en cuenta la corriente de arranque prevista y el dise\u00f1o el\u00e9ctrico real.<\/p>\n\n<h3 class=\"wp-block-heading\">No tener en cuenta la corriente nominal<\/h3>\n<p class=\"wp-block-paragraph\">Una curva adecuada combinada con una intensidad nominal incorrecta no constituye una selecci\u00f3n adecuada del interruptor.<\/p>\n\n<h3 class=\"wp-block-heading\">Ignorar la capacidad m\u00e1xima<\/h3>\n<p class=\"wp-block-paragraph\">Las caracter\u00edsticas B\/C\/D y la capacidad de frenado son par\u00e1metros independientes.<\/p>\n\n<h3 class=\"wp-block-heading\">Suponer que los datos de la curva externa se aplican autom\u00e1ticamente a todos los modelos RITOKS<\/h3>\n<p class=\"wp-block-paragraph\">Las cifras de 3\u20135 \u00d7 In, 5\u201310 \u00d7 In y 10\u201320 \u00d7 In que se utilizan en esta gu\u00eda son rangos de caracter\u00edsticas generales respaldados por la documentaci\u00f3n t\u00e9cnica oficial de los fabricantes. Las p\u00e1ginas de productos de RITOKS confirman actualmente qu\u00e9 letras de curva est\u00e1n disponibles, pero no publican las curvas completas de tiempo-corriente espec\u00edficas de cada modelo.<\/p>\n\n<h3 class=\"wp-block-heading\">C\u00f3mo crear un gr\u00e1fico de curvas sin datos de modelo<\/h3>\n<p class=\"wp-block-paragraph\">Un gr\u00e1fico de aspecto realista puede dar a entender una mayor precisi\u00f3n de la que respaldan los datos disponibles.<\/p>\n<p class=\"wp-block-paragraph\">Hasta que se disponga de documentaci\u00f3n precisa sobre la relaci\u00f3n tiempo-corriente espec\u00edfica del modelo RITOKS, la selecci\u00f3n de la curva debe basarse en la designaci\u00f3n publicada y en los requisitos del proyecto, y no en un gr\u00e1fico elaborado por cuenta propia.<\/p>\n\n\n<h2 id=\"request-technical-data\" class=\"wp-block-heading\">\u00bfCu\u00e1ndo conviene solicitar m\u00e1s datos t\u00e9cnicos?<\/h2>\n\n\n<p class=\"wp-block-paragraph\">En el caso de una consulta de abastecimiento rutinaria, conocer la designaci\u00f3n de la curva requerida puede ser suficiente para preseleccionar los modelos disponibles.<\/p>\n<p class=\"wp-block-paragraph\">Para un an\u00e1lisis t\u00e9cnico m\u00e1s detallado, es posible que los compradores necesiten documentaci\u00f3n adicional, como por ejemplo:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>caracter\u00edstica exacta de tiempo-corriente<\/li>\n<li>tolerancia a la desconexi\u00f3n instant\u00e1nea<\/li>\n<li>datos sobre la capacidad m\u00e1xima<\/li>\n<li>norma de producto aplicable<\/li>\n<li>informaci\u00f3n sobre la coordinaci\u00f3n, cuando sea necesario<\/li>\n<li>documentos de ensayo o certificaci\u00f3n espec\u00edficos de cada modelo<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">Esos requisitos deben solicitarse para el producto concreto, en lugar de deducirlos \u00fanicamente a partir de las letras B, C o D.<\/p>\n\n\n<h2 id=\"frequently-asked-questions\" class=\"wp-block-heading\">Preguntas frecuentes<\/h2>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>\u00bfCu\u00e1l es la principal diferencia entre los interruptores autom\u00e1ticos de corriente residual (MCB) de curva B, C y D?<\/summary>\n<p class=\"wp-block-paragraph\">La principal diferencia que se aborda aqu\u00ed es la zona de disparo instant\u00e1neo. En la documentaci\u00f3n habitual de los fabricantes se utilizan valores aproximados de 3\u20135 \u00d7 In para B, 5\u201310 \u00d7 In para C y 10\u201320 \u00d7 In para D.<\/p>\n<\/details>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>\u00bfEs la curva C mejor que la curva B?<\/summary>\n<p class=\"wp-block-paragraph\">No. Tienen caracter\u00edsticas de disparo diferentes. La elecci\u00f3n adecuada depende del circuito y de las condiciones de corriente de arranque previstas.<\/p>\n<\/details>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>\u00bfSe utiliza siempre la curva D para los motores?<\/summary>\n<p class=\"wp-block-paragraph\">No. La curva D se asocia habitualmente con aplicaciones que presentan una corriente de arranque elevada, y las recomendaciones de los fabricantes suelen citar como ejemplos los motores y los transformadores, pero la curva correcta depende del equipo concreto y del dise\u00f1o del sistema de protecci\u00f3n.<\/p>\n<\/details>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>\u00bfOfrece RITOKS interruptores autom\u00e1ticos de corriente residual (MCB) de curvas B, C y D?<\/summary>\n<p class=\"wp-block-paragraph\">S\u00ed, en determinadas familias. Los modelos RTSXD01 y RTSXD04 incluyen actualmente las opciones B\/C\/D. Los modelos RTSXD02, RTSXD03 y RTS-ACM60 incluyen las opciones B\/C. El modelo RTS-AC47 no tiene por el momento una designaci\u00f3n de curva confirmada.<\/p>\n<\/details>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>\u00bfLa letra de la curva me indica la capacidad de rotura?<\/summary>\n<p class=\"wp-block-paragraph\">No. Las caracter\u00edsticas de recorrido y la capacidad de frenado son par\u00e1metros distintos del producto y deben comprobarse ambos.<\/p>\n<\/details>\n\n\n\n<div class=\"wp-block-group has-ast-global-color-5-color has-ast-global-color-2-background-color has-text-color has-background is-layout-constrained wp-container-core-group-is-layout-737f6912 wp-block-group-is-layout-constrained\" style=\"border-radius:6px;margin-top:48px;padding-top:40px;padding-right:32px;padding-bottom:40px;padding-left:32px\">\n\n\n<h2 class=\"wp-block-heading\">\u00bfNecesitas ayuda para elegir la curva de disparo de un disyuntor?<\/h2>\n\n\n<p class=\"wp-block-paragraph\">RITOKS ofrece gamas de interruptores autom\u00e1ticos en miniatura de CA con diferentes intensidades nominales, configuraciones de polos, capacidades de corte y disponibilidad de curvas B\/C\/D.<\/p>\n<p class=\"wp-block-paragraph\">Utiliza un <a href=\"https:\/\/ritoks.com\/es\/ac-mcb-rfq-checklist\/\">Lista de comprobaci\u00f3n para la solicitud de presupuesto de AC MCB RFQ<\/a> proporcionar:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>Tensi\u00f3n de CA<\/li>\n<li>corriente necesaria<\/li>\n<li>configuraci\u00f3n de los polos<\/li>\n<li>curva de recorrido requerida<\/li>\n<li>capacidad de frenado necesaria<\/li>\n<li>cantidad<\/li>\n<li>solicitud<\/li>\n<li>cualquier documentaci\u00f3n t\u00e9cnica necesaria<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">A continuaci\u00f3n, RITOKS puede cotejar la consulta con las familias de productos publicadas actualmente y con los datos de modelos confirmados.<\/p>\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-ast-global-color-0-background-color has-background wp-element-button\" href=\"https:\/\/ritoks.com\/es\/product-category\/ac-power-protection\/miniature-circuit-breakers\/\">Ver interruptores autom\u00e1ticos miniatura de CA \u2192<\/a><\/div>\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-ast-global-color-0-background-color has-background wp-element-button\" href=\"https:\/\/ritoks.com\/es\/ac-mcb-selection-guide\/\">Lee la gu\u00eda de selecci\u00f3n de disyuntores de CA \u2192<\/a><\/div>\n<div class=\"wp-block-button is-style-outline is-style-outline--1\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/ritoks.com\/es\/contact-us\/\">Contacta con RITOKS \u2192 Solicita un presupuesto<\/a><\/div>\n<\/div>\n\n\n<\/div>\n\n\n<\/div>","protected":false},"excerpt":{"rendered":"<p>B Curve vs C Curve vs D Curve MCBs: What\u2019s the Difference? B, C and D curves are different tripping [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"no-sidebar","site-content-layout":"page-builder","ast-site-content-layout":"full-width-container","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"disabled","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"disabled","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ritoks_resource_detail_renderer":null,"ritoks_resource_product_cat_term_id":0,"footnotes":""},"categories":[64],"tags":[],"class_list":["post-699","post","type-post","status-publish","format-standard","hentry","category-circuit-protection"],"acf":[],"spectra_blocks_featured_image_url":null,"spectra_blocks_author_info":{"display_name":"RITOKS","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/6d7d0fc73468198f994ab13ef6eb6558c53b6ed1ad86364d5165efe8bdf8eb4a?s=96&d=mm&r=g","author_link":"https:\/\/ritoks.com\/es\/author\/dazzlingwqbgmail-com\/","description":""},"_links":{"self":[{"href":"https:\/\/ritoks.com\/es\/wp-json\/wp\/v2\/posts\/699","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ritoks.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ritoks.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ritoks.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/ritoks.com\/es\/wp-json\/wp\/v2\/comments?post=699"}],"version-history":[{"count":4,"href":"https:\/\/ritoks.com\/es\/wp-json\/wp\/v2\/posts\/699\/revisions"}],"predecessor-version":[{"id":731,"href":"https:\/\/ritoks.com\/es\/wp-json\/wp\/v2\/posts\/699\/revisions\/731"}],"wp:attachment":[{"href":"https:\/\/ritoks.com\/es\/wp-json\/wp\/v2\/media?parent=699"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ritoks.com\/es\/wp-json\/wp\/v2\/categories?post=699"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ritoks.com\/es\/wp-json\/wp\/v2\/tags?post=699"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}