{"id":739,"date":"2026-09-06T08:38:02","date_gmt":"2026-09-06T08:38:02","guid":{"rendered":"https:\/\/ritoks.com\/?p=739"},"modified":"2026-10-12T05:54:33","modified_gmt":"2026-10-12T05:54:33","slug":"rack-pdu-rfq-checklist","status":"publish","type":"post","link":"https:\/\/ritoks.com\/es\/rack-pdu-rfq-checklist\/","title":{"rendered":"Lista de comprobaci\u00f3n para la solicitud de presupuesto de una PDU de rack: lo que deben especificar los compradores"},"content":{"rendered":"\n<div class=\"wp-block-group ritoks-blog-hero is-layout-constrained wp-block-group-is-layout-constrained\">\n\n<h1 class=\"wp-block-heading\">Rack PDU RFQ Checklist: What Buyers Should Specify<\/h1>\n\n<p class=\"wp-block-paragraph\">A useful rack PDU RFQ should do more than say:<\/p>\n\n<p class=\"ritoks-hero-lead wp-block-paragraph\">\u201cPlease quote a rack PDU.\u201d<\/p>\n\n<p class=\"ritoks-hero-lead wp-block-paragraph\">Rack power distribution units can differ in voltage, current, input connection, output sockets, outlet count, rack format, cable arrangement and optional requirements.<\/p>\n\n<p class=\"ritoks-hero-lead wp-block-paragraph\">If those details are missing, the supplier may need several rounds of clarification before an exact product or variant can be compared.<\/p>\n\n<p class=\"ritoks-hero-lead wp-block-paragraph\">A better approach is to provide the requirements already defined by the project.<\/p>\n\n<p class=\"ritoks-hero-lead wp-block-paragraph\">That does not mean the supplier should automatically calculate the electrical design from a server count or a general rack description.<\/p>\n\n<p class=\"ritoks-hero-lead wp-block-paragraph\">The purpose of an RFQ is simpler:<\/p>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p>Buyer-defined requirements \u2192 product and variant matching \u2192 documentation confirmation \u2192 quotation<\/p><\/blockquote>\n\n<p class=\"ritoks-hero-lead wp-block-paragraph\">For broader guidance on comparing PDU configurations, see the <a href=\"https:\/\/ritoks.com\/rack-pdu-selection-guide\/\">Rack PDU Selection Guide<\/a>.<\/p>\n\n<figure data-spectra-id=\"spectra-84705ff4-388d-46c4-8954-d576026338ef\" class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" height=\"530\" width=\"1536\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/rack-pdu-rfq-hero.png\" alt=\"Rack PDU procurement and specification review in a data center environment\" class=\"wp-image-745\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/rack-pdu-rfq-hero.png 1536w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/rack-pdu-rfq-hero-600x207.png 600w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/rack-pdu-rfq-hero-300x104.png 300w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/rack-pdu-rfq-hero-1024x353.png 1024w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/rack-pdu-rfq-hero-768x265.png 768w\" sizes=\"auto, (max-width: 1536px) 100vw, 1536px\" \/><figcaption class=\"wp-element-caption\">Illustrative rack PDU procurement and specification-review environment.<\/figcaption><\/figure>\n\n<\/div>\n\n<div class=\"wp-block-group ritoks-toc is-layout-constrained wp-block-group-is-layout-constrained\">\n\n<h2 class=\"wp-block-heading\" id=\"contents\">Contents<\/h2>\n\n<ul class=\"wp-block-list\"><li><a href=\"#rack-pdu-rfq-quick-checklist\">Rack PDU RFQ Quick Checklist<\/a><\/li><li><a href=\"#1-specify-the-required-input-voltage\">Voltage and Current Requirements<\/a><\/li><li><a href=\"#3-keep-input-plug-and-output-socket-separate\">Input and Output Connections<\/a><\/li><li><a href=\"#6-state-the-required-outlet-count\">Outlet Count and Rack Format<\/a><\/li><li><a href=\"#10-specify-the-cord-requirement\">Cord, Switching and Protection Requirements<\/a><\/li><li><a href=\"#current-product-families-and-rfq-relevant-information\">Current Product Families<\/a><\/li><li><a href=\"#15-specify-quantity-and-project-context\">Commercial and Documentation Requirements<\/a><\/li><li><a href=\"#example-rack-pdu-rfq-template\">Example Rack PDU RFQ Template<\/a><\/li><li><a href=\"#common-rack-pdu-rfq-mistakes\">Common RFQ Mistakes<\/a><\/li><li><a href=\"#a-practical-rack-pdu-rfq-workflow\">Practical RFQ Workflow<\/a><\/li><\/ul>\n\n<\/div>\n\n<h2 class=\"wp-block-heading\" id=\"rack-pdu-rfq-quick-checklist\">Rack PDU RFQ Quick Checklist<\/h2>\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Parameter<\/th><th>What the Buyer Should Provide<\/th><th>Why It Matters<\/th><\/tr><\/thead><tbody><tr><td>Input voltage<\/td><td>Required voltage<\/td><td>PDU families may use different electrical ratings<\/td><\/tr><tr><td>Rated current<\/td><td>Required current<\/td><td>Helps narrow suitable product configurations<\/td><\/tr><tr><td>Input plug \/ connector<\/td><td>Required upstream connection<\/td><td>Input connection is separate from output socket type<\/td><\/tr><tr><td>Output sockets<\/td><td>Required receptacle format<\/td><td>Must match the equipment connection requirement<\/td><\/tr><tr><td>Outlet count<\/td><td>Required number of outputs<\/td><td>Available counts vary by product family<\/td><\/tr><tr><td>Rack format<\/td><td>1U, 0U or other project requirement<\/td><td>Physical availability must be confirmed by model<\/td><\/tr><tr><td>Cord requirement<\/td><td>Length, corded or no-cord requirement<\/td><td>Cable arrangements vary by configuration<\/td><\/tr><tr><td>Required features<\/td><td>Switch, surge, metering, monitoring, etc., if needed<\/td><td>Current availability must be confirmed<\/td><\/tr><tr><td>Quantity<\/td><td>Required quantity<\/td><td>Needed for commercial quotation<\/td><\/tr><tr><td>Documentation<\/td><td>Required drawings, specifications or evidence<\/td><td>Availability depends on exact product and variant<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<figure data-spectra-id=\"spectra-1e267698-7f94-4536-8540-5841184dd759\" class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" height=\"494\" width=\"768\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/rack-pdu-rfq-checklist-visual.png\" alt=\"Rack PDU RFQ checklist including voltage current plug socket outlet count rack format quantity and documentation\" class=\"wp-image-743\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/rack-pdu-rfq-checklist-visual.png 768w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/rack-pdu-rfq-checklist-visual-600x386.png 600w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/rack-pdu-rfq-checklist-visual-300x193.png 300w\" sizes=\"auto, (max-width: 768px) 100vw, 768px\" \/><figcaption class=\"wp-element-caption\">Key buyer-supplied information for preparing a rack PDU RFQ.<\/figcaption><\/figure>\n\n<p class=\"wp-block-paragraph\">Not every project needs every field.<\/p>\n\n<p class=\"wp-block-paragraph\">But where a requirement is already known, putting it in the initial RFQ reduces ambiguity.<\/p>\n\n<h2 class=\"wp-block-heading\" id=\"1-specify-the-required-input-voltage\">1. Specify the Required Input Voltage<\/h2>\n\n<p class=\"wp-block-paragraph\">Start with the voltage required by the project.<\/p>\n\n<p class=\"wp-block-paragraph\">Current published RITOKS rack-power products include different voltage configurations.<\/p>\n\n<p class=\"wp-block-paragraph\">For example:<\/p>\n\n<p class=\"wp-block-paragraph\">RTS-PDU-US8-15A \u2014 AC125V<\/p>\n\n<p class=\"wp-block-paragraph\">RTS-PDU1U-10A \u2014 AC250V<\/p>\n\n<p class=\"wp-block-paragraph\">These are model-specific published values.<\/p>\n\n<p class=\"wp-block-paragraph\">They are not universal voltage recommendations.<\/p>\n\n<p class=\"wp-block-paragraph\">A useful RFQ field is:<\/p>\n\n<p class=\"wp-block-paragraph\">Required input voltage: [voltage]<\/p>\n\n<p class=\"wp-block-paragraph\">If the voltage requirement has not yet been defined by the project engineering team, do not guess it simply to complete the inquiry.<\/p>\n\n<h2 class=\"wp-block-heading\" id=\"2-provide-the-required-current\">2. Provide the Required Current<\/h2>\n\n<p class=\"wp-block-paragraph\">Rated current should be stated separately from voltage.<\/p>\n\n<p class=\"wp-block-paragraph\">Current published examples include:<\/p>\n\n<p class=\"wp-block-paragraph\">RTS-PDU-US8-15A \u2014 15A<\/p>\n\n<p class=\"wp-block-paragraph\">RTS-PDU1U-10A \u2014 10A<\/p>\n\n<p class=\"wp-block-paragraph\">RTS-PDUSM also includes designated modular components with 10A or 16A markings, but RTS-PDUSM is a component family, not an assembled PDU.<\/p>\n\n<p class=\"wp-block-paragraph\">A component rating should therefore not be treated as proof of a complete rack PDU configuration with the same current.<\/p>\n\n<p class=\"wp-block-paragraph\">For the RFQ:<\/p>\n\n<p class=\"wp-block-paragraph\">Required current: [current]<\/p>\n\n<p class=\"wp-block-paragraph\">The supplier should not be assumed to determine the required current merely from the number of connected servers.<\/p>\n\n<h2 class=\"wp-block-heading\" id=\"3-keep-input-plug-and-output-socket-separate\">3. Keep Input Plug and Output Socket Separate<\/h2>\n\n<p class=\"wp-block-paragraph\">This is one of the most important parts of a rack PDU inquiry.<\/p>\n\n<h3 class=\"wp-block-heading\">Input Plug \/ Connector<\/h3>\n\n<p class=\"wp-block-paragraph\">This describes how the PDU connects to the upstream power source.<\/p>\n\n<h3 class=\"wp-block-heading\">Output Socket \/ Receptacle<\/h3>\n\n<p class=\"wp-block-paragraph\">This describes what the connected equipment plugs into.<\/p>\n\n<p class=\"wp-block-paragraph\">These are separate specifications.<\/p>\n\n<p class=\"wp-block-paragraph\">A better RFQ uses two fields:<\/p>\n\n<p class=\"wp-block-paragraph\">Input plug \/ connector: [required type]<\/p>\n\n<p class=\"wp-block-paragraph\">Output sockets: [required type]<\/p>\n\n<p class=\"wp-block-paragraph\">Do not write only:<\/p>\n\n<p class=\"wp-block-paragraph\">Plug type: [type]<\/p>\n\n<p class=\"wp-block-paragraph\">if it is unclear whether the buyer means the PDU input or the equipment-facing outputs.<\/p>\n\n<h2 class=\"wp-block-heading\" id=\"4-input-connector-requirements\">4. Input Connector Requirements<\/h2>\n\n<p class=\"wp-block-paragraph\">RITOKS currently publishes the broadest input-component selection under RTS-PDUSM.<\/p>\n\n<p class=\"wp-block-paragraph\">The component family lists options associated with:<\/p>\n\n<p class=\"wp-block-paragraph\">China 10A \/ 16A<\/p>\n\n<p class=\"wp-block-paragraph\">European<\/p>\n\n<p class=\"wp-block-paragraph\">UK<\/p>\n\n<p class=\"wp-block-paragraph\">US<\/p>\n\n<p class=\"wp-block-paragraph\">Australian<\/p>\n\n<p class=\"wp-block-paragraph\">Italian<\/p>\n\n<p class=\"wp-block-paragraph\">IEC C13 \/ C14 \/ C19 \/ C20<\/p>\n\n<p class=\"wp-block-paragraph\">16A \/ 32A industrial options<\/p>\n\n<p class=\"wp-block-paragraph\">However, RTS-PDUSM is a modular component family.<\/p>\n\n<p class=\"wp-block-paragraph\">These options do not prove that every connector can be combined with every assembled PDU configuration.<\/p>\n\n<p class=\"wp-block-paragraph\">For Products 257 and 259, the exact input plug is not currently published.<\/p>\n\n<p class=\"wp-block-paragraph\">Therefore, if input connection matters, put the required connector directly in the RFQ and ask for exact-variant confirmation.<\/p>\n\n<h2 class=\"wp-block-heading\" id=\"5-specify-the-required-output-socket-format\">5. Specify the Required Output Socket Format<\/h2>\n\n<p class=\"wp-block-paragraph\">Output socket requirements should also be written explicitly.<\/p>\n\n<p class=\"wp-block-paragraph\">Current RITOKS evidence includes:<\/p>\n\n<p class=\"wp-block-paragraph\">RTS-PDUSM<\/p>\n\n<p class=\"wp-block-paragraph\">Modular outlet components include options such as:<\/p>\n\n<p class=\"wp-block-paragraph\">universal<\/p>\n\n<p class=\"wp-block-paragraph\">regional socket modules<\/p>\n\n<p class=\"wp-block-paragraph\">C13<\/p>\n\n<p class=\"wp-block-paragraph\">C19<\/p>\n\n<p class=\"wp-block-paragraph\">C13 slide-lock<\/p>\n\n<p class=\"wp-block-paragraph\">Again, these are modular components, not proof of a complete assembled C13 or C19 rack PDU.<\/p>\n\n<p class=\"wp-block-paragraph\">RTS-PDU-US8-15A<\/p>\n\n<p class=\"wp-block-paragraph\">Published assembled configuration:<\/p>\n\n<p class=\"wp-block-paragraph\">eight grounded US-style three-slot outlets<\/p>\n\n<p class=\"wp-block-paragraph\">The exact NEMA designation is not currently published.<\/p>\n\n<p class=\"wp-block-paragraph\">RTS-PDU1U-10A<\/p>\n\n<p class=\"wp-block-paragraph\">Published configuration:<\/p>\n\n<p class=\"wp-block-paragraph\">three-slot outlets<\/p>\n\n<p class=\"wp-block-paragraph\">The exact regional outlet standard is not currently confirmed.<\/p>\n\n<p class=\"wp-block-paragraph\">A useful RFQ field is:<\/p>\n\n<p class=\"wp-block-paragraph\">Required output socket \/ receptacle: [type]<\/p>\n\n<h2 class=\"wp-block-heading\" id=\"6-state-the-required-outlet-count\">6. State the Required Outlet Count<\/h2>\n\n<p class=\"wp-block-paragraph\">Outlet count is usually one of the easiest requirements for a buyer to specify.<\/p>\n\n<p class=\"wp-block-paragraph\">Current published examples include:<\/p>\n\n<p class=\"wp-block-paragraph\">RTS-PDU-US8-15A<\/p>\n\n<p class=\"wp-block-paragraph\">8 outlets<\/p>\n\n<p class=\"wp-block-paragraph\">RTS-PDU1U-10A<\/p>\n\n<p class=\"wp-block-paragraph\">Published variants include:<\/p>\n\n<p class=\"wp-block-paragraph\">2<\/p>\n\n<p class=\"wp-block-paragraph\">3<\/p>\n\n<p class=\"wp-block-paragraph\">4<\/p>\n\n<p class=\"wp-block-paragraph\">5<\/p>\n\n<p class=\"wp-block-paragraph\">6<\/p>\n\n<p class=\"wp-block-paragraph\">7<\/p>\n\n<p class=\"wp-block-paragraph\">8<\/p>\n\n<p class=\"wp-block-paragraph\">10<\/p>\n\n<p class=\"wp-block-paragraph\">12<\/p>\n\n<p class=\"wp-block-paragraph\">14 outlets<\/p>\n\n<p class=\"wp-block-paragraph\">For an inquiry:<\/p>\n\n<p class=\"wp-block-paragraph\">Required outlet count: [number]<\/p>\n\n<p class=\"wp-block-paragraph\">Do not assume that more outlets mean more electrical capacity.<\/p>\n\n<p class=\"wp-block-paragraph\">Outlet count, current and voltage are separate specifications.<\/p>\n\n<h2 class=\"wp-block-heading\" id=\"7-if-you-need-a-mixed-outlet-layout-state-it-separately\">7. If You Need a Mixed Outlet Layout, State It Separately<\/h2>\n\n<p class=\"wp-block-paragraph\">Some projects may require more than one socket format in the same power-distribution assembly.<\/p>\n\n<p class=\"wp-block-paragraph\">A buyer may include:<\/p>\n\n<p class=\"wp-block-paragraph\">Required outlet mix: [requirement]<\/p>\n\n<p class=\"wp-block-paragraph\">But this should be treated as a request requiring confirmation, not as a currently guaranteed RITOKS configuration.<\/p>\n\n<p class=\"wp-block-paragraph\">RTS-PDUSM provides multiple modular socket component types, but current product evidence does not establish every possible assembled mixed-socket PDU combination.<\/p>\n\n<h2 class=\"wp-block-heading\" id=\"8-specify-the-required-rack-format\">8. Specify the Required Rack Format<\/h2>\n\n<p class=\"wp-block-paragraph\">If the project already defines the physical rack format, include it.<\/p>\n\n<p class=\"wp-block-paragraph\">For example:<\/p>\n\n<p class=\"wp-block-paragraph\">Rack format: [required format]<\/p>\n\n<p class=\"wp-block-paragraph\">Current published examples include the RTS-PDU1U-10A in a 1U format. The P Series supplier documentation also illustrates 1U, 2U and 0U formats; availability depends on the selected platform and outlet configuration. PC and PD list horizontal or vertical mounting options.<\/p>\n\n<p class=\"wp-block-paragraph\">Specify the required rack format and mounting orientation in the RFQ, and request confirmation for the exact configuration. These examples do not establish the mounting format, dimensions or hardware for every RITOKS rack PDU.<\/p>\n\n<p class=\"wp-block-paragraph\">A buyer may still request:<\/p>\n\n<p class=\"wp-block-paragraph\">0U required<\/p>\n\n<p class=\"wp-block-paragraph\">or:<\/p>\n\n<p class=\"wp-block-paragraph\">Vertical mounting required<\/p>\n\n<p class=\"wp-block-paragraph\">but that should be treated as a project requirement whose product availability needs confirmation.<\/p>\n\n<p class=\"wp-block-paragraph\">Do not turn the buyer\u2019s request into a claim that RITOKS already offers that format.<\/p>\n\n<h2 class=\"wp-block-heading\" id=\"9-include-available-rack-space-or-dimensional-constraints\">9. Include Available Rack Space or Dimensional Constraints<\/h2>\n\n<p class=\"wp-block-paragraph\">For OEM racks and cabinets, available physical space can matter.<\/p>\n\n<p class=\"wp-block-paragraph\">Useful RFQ information may include:<\/p>\n\n<p class=\"wp-block-paragraph\">maximum width<\/p>\n\n<p class=\"wp-block-paragraph\">maximum depth<\/p>\n\n<p class=\"wp-block-paragraph\">available rack units<\/p>\n\n<p class=\"wp-block-paragraph\">mounting-clearance requirement<\/p>\n\n<p class=\"wp-block-paragraph\">mounting-hardware requirement<\/p>\n\n<p class=\"wp-block-paragraph\">A suitable field is:<\/p>\n\n<p class=\"wp-block-paragraph\">Available space \/ dimensional constraint: [requirement]<\/p>\n\n<p class=\"wp-block-paragraph\">Current rack-product pages do not publish all of the dimensional and mounting details needed for every variant, so exact drawings should be requested where mechanical fit is important.<\/p>\n\n<h2 class=\"wp-block-heading\" id=\"10-specify-the-cord-requirement\">10. Specify the Cord Requirement<\/h2>\n\n<p class=\"wp-block-paragraph\">Cable configuration should not be overlooked.<\/p>\n\n<p class=\"wp-block-paragraph\">Current product evidence includes:<\/p>\n\n<p class=\"wp-block-paragraph\">RTS-PDU-US8-15A<\/p>\n\n<p class=\"wp-block-paragraph\">1.8m cable on the assembled configuration<\/p>\n\n<p class=\"wp-block-paragraph\">RTS-PDU1U-10A<\/p>\n\n<p class=\"wp-block-paragraph\">2m cord option<\/p>\n\n<p class=\"wp-block-paragraph\">no-cord variant<\/p>\n\n<p class=\"wp-block-paragraph\">A buyer can therefore include:<\/p>\n\n<p class=\"wp-block-paragraph\">Cord requirement: [length \/ no-cord \/ other requirement]<\/p>\n\n<p class=\"wp-block-paragraph\">If a different cord length, plug or cable arrangement is needed, list it as a requirement and ask for exact-variant confirmation.<\/p>\n\n<p class=\"wp-block-paragraph\">Do not assume every requested customization is automatically available.<\/p>\n\n<h2 class=\"wp-block-heading\" id=\"11-state-whether-a-master-switch-is-required\">11. State Whether a Master Switch Is Required<\/h2>\n\n<p class=\"wp-block-paragraph\">Some projects may need a local master switch.<\/p>\n\n<p class=\"wp-block-paragraph\">Current published data confirms:<\/p>\n\n<p class=\"wp-block-paragraph\">RTS-PDU1U-10A<\/p>\n\n<p class=\"wp-block-paragraph\">double-pole master switch<\/p>\n\n<p class=\"wp-block-paragraph\">RTS-PDU-US8-15A is supplier-described as having a surge-protected switch, although detailed surge-performance data remains pending.<\/p>\n\n<p class=\"wp-block-paragraph\">For an RFQ:<\/p>\n\n<p class=\"wp-block-paragraph\">Master switch requirement: [yes \/ no \/ specified requirement]<\/p>\n\n<p class=\"wp-block-paragraph\">A local master switch should not be confused with intelligent remote outlet switching.<\/p>\n\n<p class=\"wp-block-paragraph\">Current RITOKS product pages do not confirm remote-switched PDU functionality.<\/p>\n\n<h2 class=\"wp-block-heading\" id=\"12-advanced-features-can-be-requested-but-availability-must-be-confirmed\">12. Advanced Features Can Be Requested \u2014 But Availability Must Be Confirmed<\/h2>\n\n<p class=\"wp-block-paragraph\">A project may require features such as:<\/p>\n\n<p class=\"wp-block-paragraph\">metering<\/p>\n\n<p class=\"wp-block-paragraph\">remote outlet switching<\/p>\n\n<p class=\"wp-block-paragraph\">network monitoring<\/p>\n\n<p class=\"wp-block-paragraph\">SNMP<\/p>\n\n<p class=\"wp-block-paragraph\">environmental monitoring<\/p>\n\n<p class=\"wp-block-paragraph\">ATS functionality<\/p>\n\n<p class=\"wp-block-paragraph\">These can be included in a buyer\u2019s RFQ.<\/p>\n\n<p class=\"wp-block-paragraph\">For example:<\/p>\n\n<p class=\"wp-block-paragraph\">Metering required: [requirement]<\/p>\n\n<p class=\"wp-block-paragraph\">Remote monitoring required: [requirement]<\/p>\n\n<p class=\"wp-block-paragraph\">RITOKS now publishes platform-specific monitoring and switching capabilities in its P Series smart rack PDU family. PB, PC and PD list SNMP; PC and PD list outlet-level switching. Check the required functions against the selected platform and exact configuration.<\/p>\n\n<p class=\"wp-block-paragraph\">The safe wording is:<\/p>\n\n<p class=\"wp-block-paragraph\">Include the requirement if your project needs it; availability must be confirmed for the exact product.<\/p>\n\n<p class=\"wp-block-paragraph\">Do not assume that an advanced feature exists simply because it is common elsewhere in the rack PDU market.<\/p>\n\n<h2 class=\"wp-block-heading\" id=\"13-be-specific-about-surge-protection-requirements\">13. Be Specific About Surge-Protection Requirements<\/h2>\n\n<p class=\"wp-block-paragraph\">Surge-related requirements also need careful wording.<\/p>\n\n<p class=\"wp-block-paragraph\">Current evidence includes:<\/p>\n\n<p class=\"wp-block-paragraph\">RTS-PDUSM<\/p>\n\n<p class=\"wp-block-paragraph\">SPD module option<\/p>\n\n<p class=\"wp-block-paragraph\">RTS-PDU-US8-15A<\/p>\n\n<p class=\"wp-block-paragraph\">supplier-described surge-protected switch<\/p>\n\n<p class=\"wp-block-paragraph\">However, exact surge ratings, test evidence and protection levels are not currently published.<\/p>\n\n<p class=\"wp-block-paragraph\">A buyer can therefore specify:<\/p>\n\n<p class=\"wp-block-paragraph\">Required surge protection: [project requirement]<\/p>\n\n<p class=\"wp-block-paragraph\">and:<\/p>\n\n<p class=\"wp-block-paragraph\">Required surge documentation: [document requirement]<\/p>\n\n<p class=\"wp-block-paragraph\">Do not assume a joule rating, protection level or certification that has not been published.<\/p>\n\n<h2 class=\"wp-block-heading\" id=\"14-breaker-or-fuse-requirements-should-be-listed-as-buyer-requirements\">14. Breaker or Fuse Requirements Should Be Listed as Buyer Requirements<\/h2>\n\n<p class=\"wp-block-paragraph\">Current product pages do not publish enough information to confirm breaker or fuse configurations across the reviewed Rack Power Distribution products.<\/p>\n\n<p class=\"wp-block-paragraph\">If the project requires a particular protection arrangement, state it:<\/p>\n\n<p class=\"wp-block-paragraph\">Breaker \/ fuse requirement: [requirement]<\/p>\n\n<p class=\"wp-block-paragraph\">Availability then needs exact-product confirmation.<\/p>\n\n<p class=\"wp-block-paragraph\">Do not treat the RFQ field itself as evidence that the supplier already offers the requested protection device.<\/p>\n\n<h2 class=\"wp-block-heading\" id=\"current-product-families-and-rfq-relevant-information\">Current Product Families and RFQ-Relevant Information<\/h2>\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Product<\/th><th>Useful Published Information<\/th><th>What Still Needs Confirmation<\/th><\/tr><\/thead><tbody><tr><td>RTS-PDUSM<\/td><td>Modular input\/socket components; regional, C13\/C19 and other connector options; designated 10A\/16A modules<\/td><td>Exact voltage, assembled configuration, outlet count, rack format, cord, dimensions and certifications<\/td><\/tr><tr><td>RTS-PDU-US8-15A<\/td><td>AC125V, 15A, 1875W, 8 US-style outlets, 1.8m cable<\/td><td>Exact input plug, NEMA type, rack format, dimensions, certification and detailed surge evidence<\/td><\/tr><tr><td>RTS-PDU1U-10A<\/td><td>AC250V, 10A, 2500W, 1U, 2\u201314 outlet variants, 2m\/no-cord options, double-pole master switch<\/td><td>Exact input plug, regional outlet standard, dimensions, mounting hardware and certification<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p class=\"wp-block-paragraph\">This table is for RFQ preparation only.<\/p>\n\n<p class=\"wp-block-paragraph\">It does not imply that missing fields can be inferred from the published ones.<\/p>\n\n<h2 class=\"wp-block-heading\" id=\"15-specify-quantity-and-project-context\">15. Specify Quantity and Project Context<\/h2>\n\n<p class=\"wp-block-paragraph\">Commercial information matters too.<\/p>\n\n<p class=\"wp-block-paragraph\">Include:<\/p>\n\n<p class=\"wp-block-paragraph\">Quantity: [required quantity]<\/p>\n\n<p class=\"wp-block-paragraph\">Project \/ rack context: [brief description]<\/p>\n\n<p class=\"wp-block-paragraph\">The context may help distinguish, for example:<\/p>\n\n<p class=\"wp-block-paragraph\">a single rack requirement<\/p>\n\n<p class=\"wp-block-paragraph\">a panel or enclosure project<\/p>\n\n<p class=\"wp-block-paragraph\">a prototype<\/p>\n\n<p class=\"wp-block-paragraph\">a production batch<\/p>\n\n<p class=\"wp-block-paragraph\">a repeated sourcing requirement<\/p>\n\n<p class=\"wp-block-paragraph\">But project context should not be used as a substitute for electrical specifications.<\/p>\n\n<h2 class=\"wp-block-heading\" id=\"16-include-the-destination-country-or-region\">16. Include the Destination Country or Region<\/h2>\n\n<p class=\"wp-block-paragraph\">Destination information can help clarify commercial and documentation requirements.<\/p>\n\n<p class=\"wp-block-paragraph\">Use:<\/p>\n\n<p class=\"wp-block-paragraph\">Destination: [country \/ region]<\/p>\n\n<p class=\"wp-block-paragraph\">This can be relevant to:<\/p>\n\n<p class=\"wp-block-paragraph\">required documentation<\/p>\n\n<p class=\"wp-block-paragraph\">plug\/socket requirements<\/p>\n\n<p class=\"wp-block-paragraph\">labeling<\/p>\n\n<p class=\"wp-block-paragraph\">packaging<\/p>\n\n<p class=\"wp-block-paragraph\">shipping arrangements<\/p>\n\n<p class=\"wp-block-paragraph\">However, destination information does not mean regulatory compliance is automatically guaranteed.<\/p>\n\n<p class=\"wp-block-paragraph\">Any required market approval or certification should be stated explicitly.<\/p>\n\n<h2 class=\"wp-block-heading\" id=\"17-separate-standards-certificates-and-test-reports\">17. Separate Standards, Certificates and Test Reports<\/h2>\n\n<p class=\"wp-block-paragraph\">If a project requires technical or compliance documentation, say exactly what is required.<\/p>\n\n<p class=\"wp-block-paragraph\">Possible RFQ requests include:<\/p>\n\n<p class=\"wp-block-paragraph\">datasheet<\/p>\n\n<p class=\"wp-block-paragraph\">dimensional drawing<\/p>\n\n<p class=\"wp-block-paragraph\">connection information<\/p>\n\n<p class=\"wp-block-paragraph\">plug\/socket specification<\/p>\n\n<p class=\"wp-block-paragraph\">certification evidence<\/p>\n\n<p class=\"wp-block-paragraph\">test report<\/p>\n\n<p class=\"wp-block-paragraph\">surge documentation<\/p>\n\n<p class=\"wp-block-paragraph\">product photos<\/p>\n\n<p class=\"wp-block-paragraph\">packaging drawing<\/p>\n\n<p class=\"wp-block-paragraph\">A standard reference is not automatically the same as:<\/p>\n\n<p class=\"wp-block-paragraph\">a certificate<\/p>\n\n<p class=\"wp-block-paragraph\">a test report<\/p>\n\n<p class=\"wp-block-paragraph\">a market approval<\/p>\n\n<p class=\"wp-block-paragraph\">Use wording such as:<\/p>\n\n<p class=\"wp-block-paragraph\">Required standard: [standard]<\/p>\n\n<p class=\"wp-block-paragraph\">Required certification\/evidence: [document]<\/p>\n\n<p class=\"wp-block-paragraph\">Required technical documents: [list]<\/p>\n\n<p class=\"wp-block-paragraph\">Availability should then be confirmed for the exact product and variant.<\/p>\n\n<h2 class=\"wp-block-heading\" id=\"18-packaging-labeling-and-oem-requests\">18. Packaging, Labeling and OEM Requests<\/h2>\n\n<p class=\"wp-block-paragraph\">A buyer may also include commercial customization requirements, such as:<\/p>\n\n<p class=\"wp-block-paragraph\">packaging<\/p>\n\n<p class=\"wp-block-paragraph\">labeling<\/p>\n\n<p class=\"wp-block-paragraph\">logo<\/p>\n\n<p class=\"wp-block-paragraph\">private label<\/p>\n\n<p class=\"wp-block-paragraph\">OEM branding<\/p>\n\n<p class=\"wp-block-paragraph\">custom faceplate<\/p>\n\n<p class=\"wp-block-paragraph\">custom plug<\/p>\n\n<p class=\"wp-block-paragraph\">custom cord<\/p>\n\n<p class=\"wp-block-paragraph\">socket arrangement<\/p>\n\n<p class=\"wp-block-paragraph\">These are valid RFQ questions.<\/p>\n\n<p class=\"wp-block-paragraph\">But current evidence does not support a universal claim that every RITOKS rack-power product supports every customization.<\/p>\n\n<p class=\"wp-block-paragraph\">Use:<\/p>\n\n<p class=\"wp-block-paragraph\">Packaging \/ labeling requirement: [requirement]<\/p>\n\n<p class=\"wp-block-paragraph\">OEM \/ branding requirement: [requirement]<\/p>\n\n<p class=\"wp-block-paragraph\">Custom configuration request: [requirement]<\/p>\n\n<p class=\"wp-block-paragraph\">and ask for availability confirmation.<\/p>\n\n<h2 class=\"wp-block-heading\" id=\"example-rack-pdu-rfq-template\">Example Rack PDU RFQ Template<\/h2>\n\n<p class=\"wp-block-paragraph\">Use the following template as a starting point.<\/p>\n\n<h3 class=\"wp-block-heading\">Project Information<\/h3>\n\n<p class=\"wp-block-paragraph\">Company: [company]<\/p>\n\n<p class=\"wp-block-paragraph\">Project \/ rack context: [description]<\/p>\n\n<p class=\"wp-block-paragraph\">Destination: [country \/ region]<\/p>\n\n<p class=\"wp-block-paragraph\">Quantity: [quantity]<\/p>\n\n<p class=\"wp-block-paragraph\">Required delivery: [schedule]<\/p>\n\n<h3 class=\"wp-block-heading\">Electrical and Connection Requirements<\/h3>\n\n<p class=\"wp-block-paragraph\">Input voltage: [required voltage]<\/p>\n\n<p class=\"wp-block-paragraph\">Rated current: [required current]<\/p>\n\n<p class=\"wp-block-paragraph\">Required power rating: [if specified]<\/p>\n\n<p class=\"wp-block-paragraph\">Input plug \/ connector: [required type]<\/p>\n\n<p class=\"wp-block-paragraph\">Output sockets: [required type]<\/p>\n\n<p class=\"wp-block-paragraph\">Outlet count: [number]<\/p>\n\n<p class=\"wp-block-paragraph\">Outlet mix: [if required]<\/p>\n\n<h3 class=\"wp-block-heading\">Physical Requirements<\/h3>\n\n<p class=\"wp-block-paragraph\">Rack format: [1U \/ 0U \/ other requirement]<\/p>\n\n<p class=\"wp-block-paragraph\">Orientation: [if specified]<\/p>\n\n<p class=\"wp-block-paragraph\">Available space: [dimensions \/ constraint]<\/p>\n\n<p class=\"wp-block-paragraph\">Cord requirement: [length \/ no-cord \/ other]<\/p>\n\n<p class=\"wp-block-paragraph\">Mounting hardware: [if required]<\/p>\n\n<h3 class=\"wp-block-heading\">Optional Features<\/h3>\n\n<p class=\"wp-block-paragraph\">Master switch: [requirement]<\/p>\n\n<p class=\"wp-block-paragraph\">Surge protection: [requirement]<\/p>\n\n<p class=\"wp-block-paragraph\">Breaker \/ fuse: [requirement]<\/p>\n\n<p class=\"wp-block-paragraph\">Metering: [if required]<\/p>\n\n<p class=\"wp-block-paragraph\">Remote switching: [if required]<\/p>\n\n<p class=\"wp-block-paragraph\">Monitoring \/ SNMP: [if required]<\/p>\n\n<p class=\"wp-block-paragraph\">Environmental monitoring: [if required]<\/p>\n\n<h3 class=\"wp-block-heading\">Documentation and Commercial Requirements<\/h3>\n\n<p class=\"wp-block-paragraph\">Required standard: [if specified]<\/p>\n\n<p class=\"wp-block-paragraph\">Certification evidence: [if required]<\/p>\n\n<p class=\"wp-block-paragraph\">Technical documents: [list]<\/p>\n\n<p class=\"wp-block-paragraph\">Packaging \/ labeling: [requirement]<\/p>\n\n<p class=\"wp-block-paragraph\">OEM \/ private-label requirement: [if applicable]<\/p>\n\n<p class=\"wp-block-paragraph\">Preferred model \/ family: [if known]<\/p>\n\n<h3 class=\"wp-block-heading\">Additional Notes<\/h3>\n\n<p class=\"wp-block-paragraph\">Other requirements: [details]<\/p>\n\n<p class=\"wp-block-paragraph\">This template communicates project requirements.<\/p>\n\n<p class=\"wp-block-paragraph\">It does not replace electrical or rack-system engineering.<\/p>\n\n<h2 class=\"wp-block-heading\" id=\"what-if-some-requirements-are-not-yet-known\">What If Some Requirements Are Not Yet Known?<\/h2>\n\n<p class=\"wp-block-paragraph\">An RFQ does not need invented answers.<\/p>\n\n<p class=\"wp-block-paragraph\">If a parameter is still pending, write that clearly.<\/p>\n\n<p class=\"wp-block-paragraph\">For example:<\/p>\n\n<p class=\"wp-block-paragraph\">Input plug: To be confirmed<\/p>\n\n<p class=\"wp-block-paragraph\">Rack format: Project requirement pending<\/p>\n\n<p class=\"wp-block-paragraph\">Surge specification: To be defined<\/p>\n\n<p class=\"wp-block-paragraph\">That is safer than selecting a specification without supporting project information.<\/p>\n\n<p class=\"wp-block-paragraph\">The supplier can identify which details remain necessary for product matching.<\/p>\n\n<h2 class=\"wp-block-heading\" id=\"common-rack-pdu-rfq-mistakes\">Common Rack PDU RFQ Mistakes<\/h2>\n\n<h3 class=\"wp-block-heading\">Writing Only \u201c8-Outlet PDU\u201d<\/h3>\n\n<p class=\"wp-block-paragraph\">Outlet count alone does not identify voltage, current, input connector or socket format.<\/p>\n\n<h3 class=\"wp-block-heading\">Using \u201cPlug Type\u201d Without Saying Input or Output<\/h3>\n\n<p class=\"wp-block-paragraph\">Input connector and output receptacle are different requirements.<\/p>\n\n<h3 class=\"wp-block-heading\">Assuming C13\/C19 Components Mean an Assembled PDU Exists<\/h3>\n\n<p class=\"wp-block-paragraph\">RTS-PDUSM is a component family.<\/p>\n\n<p class=\"wp-block-paragraph\">Exact assembled configurations require confirmation.<\/p>\n\n<h3 class=\"wp-block-heading\" id=\"requesting-0u-ritoks-pdu-as-though-it-is-already-published\">Requesting 0U Without Confirming the Exact Configuration<\/h3>\n\n<p class=\"wp-block-paragraph\">P Series supplier documentation includes 0U examples, but the rack format still depends on the selected platform and outlet configuration. State the 0U requirement and request the exact dimensions and mounting details before confirming mechanical fit.<\/p>\n\n<h3 class=\"wp-block-heading\">Calling Any Switch a \u201cSwitched PDU\u201d<\/h3>\n\n<p class=\"wp-block-paragraph\">A local master switch is not the same as remote outlet-level switching.<\/p>\n\n<h3 class=\"wp-block-heading\">Asking for \u201cSmart PDU\u201d Without Defining the Required Feature<\/h3>\n\n<p class=\"wp-block-paragraph\">Specify whether the project needs:<\/p>\n\n<p class=\"wp-block-paragraph\">metering<\/p>\n\n<p class=\"wp-block-paragraph\">remote switching<\/p>\n\n<p class=\"wp-block-paragraph\">network monitoring<\/p>\n\n<p class=\"wp-block-paragraph\">SNMP<\/p>\n\n<p class=\"wp-block-paragraph\">environmental monitoring<\/p>\n\n<p class=\"wp-block-paragraph\">Availability can then be checked.<\/p>\n\n<h3 class=\"wp-block-heading\">Asking for \u201cCertified PDU\u201d Without Naming the Evidence<\/h3>\n\n<p class=\"wp-block-paragraph\">State the standard, certificate, test report or market approval actually required.<\/p>\n\n<h3 class=\"wp-block-heading\">Assuming More Outlets Mean More Capacity<\/h3>\n\n<p class=\"wp-block-paragraph\">Outlet count and electrical capacity are separate requirements.<\/p>\n\n<h2 class=\"wp-block-heading\" id=\"a-practical-rack-pdu-rfq-workflow\">A Practical Rack PDU RFQ Workflow<\/h2>\n\n<figure data-spectra-id=\"spectra-21b5814d-787f-4f98-ab3a-4a6105ebce97\" class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" height=\"494\" width=\"768\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/rack-pdu-rfq-workflow.png\" alt=\"Rack PDU RFQ workflow from project requirements to quotation\" class=\"wp-image-744\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/rack-pdu-rfq-workflow.png 768w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/rack-pdu-rfq-workflow-600x386.png 600w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/rack-pdu-rfq-workflow-300x193.png 300w\" sizes=\"auto, (max-width: 768px) 100vw, 768px\" \/><figcaption class=\"wp-element-caption\">Conceptual sourcing workflow from project requirements through exact variant and documentation confirmation to quotation.<\/figcaption><\/figure>\n\n<p class=\"wp-block-paragraph\">A simple procurement process is:<\/p>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p>Project requirement \u2192 RFQ checklist \u2192 Candidate product family \u2192 Exact variant confirmation \u2192 Documentation confirmation \u2192 Quotation<\/p><\/blockquote>\n\n<p class=\"wp-block-paragraph\">The goal is not to make the supplier guess the engineering requirement.<\/p>\n\n<p class=\"wp-block-paragraph\">The goal is to provide enough information for accurate product and variant matching.<\/p>\n\n<h2 class=\"wp-block-heading\" id=\"frequently-asked-questions\">Frequently Asked Questions<\/h2>\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>What Information Should I Include in a Rack PDU RFQ?<\/summary>\n\n<p class=\"wp-block-paragraph\">At minimum, provide the requirements already known for voltage, current, input connector, output sockets, outlet count, quantity and project context.<\/p>\n\n\n<p class=\"wp-block-paragraph\">Rack format, cord, documentation and optional features should also be included where relevant.<\/p>\n\n<\/details>\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Should I Specify the Input Plug and Output Sockets Separately?<\/summary>\n\n<p class=\"wp-block-paragraph\">Yes.<\/p>\n\n\n<p class=\"wp-block-paragraph\">The input connector determines how the PDU receives power, while the output sockets connect the equipment.<\/p>\n\n<\/details>\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Can I Request a 0U PDU?<\/summary>\n\n<p class=\"wp-block-paragraph\">Yes, you can state 0U as a project requirement.<\/p>\n\n\n<p class=\"wp-block-paragraph\">However, current reviewed RITOKS product data does not confirm a 0U model, so availability must be checked.<\/p>\n\n<\/details>\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Can I Request C13 or C19 Outputs?<\/summary>\n\n<p class=\"wp-block-paragraph\">You can include C13 or C19 as a required output format.<\/p>\n\n\n<p class=\"wp-block-paragraph\">Current RITOKS data confirms C13\/C19 modular components under RTS-PDUSM, but not a complete assembled C13\/C19 PDU family.<\/p>\n\n<\/details>\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Can I Request Metering or SNMP?<\/summary>\n\n<p class=\"wp-block-paragraph\">Yes, if those features are required by your project.<\/p>\n\n\n<p class=\"wp-block-paragraph\">RITOKS now publishes separate <a href=\"https:\/\/ritoks.com\/product-category\/rack-power-distribution\/smart-rack-pdus\/\">smart rack PDU<\/a>, <a href=\"https:\/\/ritoks.com\/product-category\/rack-power-distribution\/metered-rack-pdus\/\">metered rack PDU<\/a> and <a href=\"https:\/\/ritoks.com\/product-category\/rack-power-distribution\/ats-rack-pdus\/\">ATS rack PDU<\/a> families. Use the <a href=\"https:\/\/ritoks.com\/products\/p-series-smart-rack-pdu\/\">P Series<\/a>, <a href=\"https:\/\/ritoks.com\/products\/local-display-metered-rack-pdu-16a-63a\/\">Local-Display Metered<\/a> and <a href=\"https:\/\/ritoks.com\/products\/la-pd-series-dual-input-ats-rack-pdu\/\">LA-PD ATS<\/a> pages only to verify their documented functions; the exact monitoring, protocol, transfer and configuration requirements must still be stated in the RFQ.<\/p>\n\n<\/details>\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Can I Request Custom Packaging or OEM Branding?<\/summary>\n\n<p class=\"wp-block-paragraph\">You may include those requirements in the RFQ.<\/p>\n\n\n<p class=\"wp-block-paragraph\">Current evidence does not support a universal claim that all rack-power products support private labeling or custom packaging, so availability should be confirmed by product and quantity.<\/p>\n\n<\/details>\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Does RITOKS Calculate the Required PDU From My Server Count?<\/summary>\n\n<p class=\"wp-block-paragraph\">The current site does not support that claim.<\/p>\n\n\n<p class=\"wp-block-paragraph\">Provide electrical and rack requirements already defined by the project rather than using server count as an automatic sizing input.<\/p>\n\n<\/details>\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Do I Need a New Website Form to Send This Information?<\/summary>\n\n<p class=\"wp-block-paragraph\">No.<\/p>\n\n\n<p class=\"wp-block-paragraph\">The existing RITOKS inquiry form includes a free-text requirements, quantity and specifications field where these details can be entered.<\/p>\n\n<\/details>\n\n<h2 class=\"wp-block-heading\" id=\"ready-to-send-a-rack-pdu-rfq\">Ready to Send a Rack PDU RFQ?<\/h2>\n\n<p class=\"wp-block-paragraph\">A strong Rack PDU RFQ separates:<\/p>\n\n<p class=\"wp-block-paragraph\">confirmed project requirements<\/p>\n\n<p class=\"wp-block-paragraph\">from:<\/p>\n\n<p class=\"wp-block-paragraph\">items that still require product or variant confirmation.<\/p>\n\n<p class=\"wp-block-paragraph\">Before sending your inquiry, review:<\/p>\n\n<p class=\"wp-block-paragraph\">input voltage<\/p>\n\n<p class=\"wp-block-paragraph\">rated current<\/p>\n\n<p class=\"wp-block-paragraph\">input connector<\/p>\n\n<p class=\"wp-block-paragraph\">output sockets<\/p>\n\n<p class=\"wp-block-paragraph\">outlet count<\/p>\n\n<p class=\"wp-block-paragraph\">rack format<\/p>\n\n<p class=\"wp-block-paragraph\">cord<\/p>\n\n<p class=\"wp-block-paragraph\">optional feature requirements<\/p>\n\n<p class=\"wp-block-paragraph\">quantity<\/p>\n\n<p class=\"wp-block-paragraph\">technical documents<\/p>\n\n<p class=\"wp-block-paragraph\">destination<\/p>\n\n<p class=\"wp-block-paragraph\">delivery schedule<\/p>\n\n<p class=\"wp-block-paragraph\">Then send those requirements together with any preferred RITOKS product family.<\/p>\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/ritoks.com\/product-category\/rack-power-distribution\/\">View Rack Power Distribution \u2192<\/a><\/p>\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/ritoks.com\/product-category\/rack-power-distribution\/rack-pdus-socket-modules\/\">View Rack PDUs &amp; Socket Modules \u2192<\/a><\/p>\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/ritoks.com\/rack-pdu-selection-guide\/\">Read the Rack PDU Selection Guide \u2192<\/a><\/p>\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/ritoks.com\/products\/modular-pdu-outlet-socket-components-c13-c19-regional-options\/\">View RTS-PDUSM Modular Components \u2192<\/a><\/p>\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/ritoks.com\/products\/8-outlet-us-rack-pdu-15a-125v-surge-protected-switch\/\">View RTS-PDU-US8-15A \u2192<\/a><\/p>\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/ritoks.com\/products\/2-14-outlet-1u-rack-pdu-10a-250v-double-pole-switch\/\">View RTS-PDU1U-10A \u2192<\/a><\/p>\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/ritoks.com\/contact-us\/\">Contact RITOKS \u2192 Send Your RFQ<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Rack PDU RFQ Checklist: What Buyers Should Specify A useful rack PDU RFQ should do more than say: \u201cPlease quote [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"no-sidebar","site-content-layout":"page-builder","ast-site-content-layout":"full-width-container","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"disabled","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ritoks_resource_detail_renderer":null,"ritoks_resource_product_cat_term_id":0,"footnotes":""},"categories":[67],"tags":[],"class_list":["post-739","post","type-post","status-publish","format-standard","hentry","category-rack-power-distribution"],"acf":[],"spectra_blocks_featured_image_url":null,"spectra_blocks_author_info":{"display_name":"RITOKS","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/6d7d0fc73468198f994ab13ef6eb6558c53b6ed1ad86364d5165efe8bdf8eb4a?s=96&d=mm&r=g","author_link":"https:\/\/ritoks.com\/es\/author\/dazzlingwqbgmail-com\/","description":""},"_links":{"self":[{"href":"https:\/\/ritoks.com\/es\/wp-json\/wp\/v2\/posts\/739","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ritoks.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ritoks.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ritoks.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/ritoks.com\/es\/wp-json\/wp\/v2\/comments?post=739"}],"version-history":[{"count":7,"href":"https:\/\/ritoks.com\/es\/wp-json\/wp\/v2\/posts\/739\/revisions"}],"predecessor-version":[{"id":2461,"href":"https:\/\/ritoks.com\/es\/wp-json\/wp\/v2\/posts\/739\/revisions\/2461"}],"wp:attachment":[{"href":"https:\/\/ritoks.com\/es\/wp-json\/wp\/v2\/media?parent=739"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ritoks.com\/es\/wp-json\/wp\/v2\/categories?post=739"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ritoks.com\/es\/wp-json\/wp\/v2\/tags?post=739"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}