{"id":668,"date":"2026-09-05T09:23:49","date_gmt":"2026-09-05T09:23:49","guid":{"rendered":"https:\/\/ritoks.com\/?p=668"},"modified":"2026-09-23T14:09:11","modified_gmt":"2026-09-23T14:09:11","slug":"how-to-choose-dc-circuit-breaker-mcb-vs-mccb","status":"publish","type":"post","link":"https:\/\/ritoks.com\/fi\/how-to-choose-dc-circuit-breaker-mcb-vs-mccb\/","title":{"rendered":"Kuinka valita tasavirtakatkaisija: MCB vai MCCB"},"content":{"rendered":"<div class=\"wp-block-group alignfull has-ast-global-color-5-color has-ast-global-color-2-background-color has-text-color has-background is-layout-constrained wp-container-core-group-is-layout-154c5234 wp-block-group-is-layout-constrained\" style=\"padding-top:clamp(40px, 5.625vw, 72px);padding-right:24px;padding-bottom:clamp(40px, 5.625vw, 72px);padding-left:24px\">\n<h1 class=\"wp-block-heading\">Kuinka valita tasavirtakatkaisija: MCB vai MCCB<\/h1>\n\n\n\n<figure data-spectra-id=\"spectra-936006bd-1c9b-4fa7-9fa4-65ff5895c9c5\" class=\"wp-block-image size-full has-custom-border\" ><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/dc-mcb-mccb-solar-industrial-environment.jpg\" alt=\"DC-MCB- ja MCCB-katkaisijat aurinkoenergia- ja teollisuuden tasavirta-s\u00e4hk\u00f6ymp\u00e4rist\u00f6iss\u00e4\" class=\"wp-image-672\" width=\"1672\" height=\"941\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/dc-mcb-mccb-solar-industrial-environment.jpg 1672w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/dc-mcb-mccb-solar-industrial-environment-600x338.jpg 600w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/dc-mcb-mccb-solar-industrial-environment-300x169.jpg 300w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/dc-mcb-mccb-solar-industrial-environment-1024x576.jpg 1024w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/dc-mcb-mccb-solar-industrial-environment-768x432.jpg 768w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/dc-mcb-mccb-solar-industrial-environment-1536x864.jpg 1536w\" sizes=\"auto, (max-width: 1672px) 100vw, 1672px\" \/><figcaption class=\"wp-element-caption\">Tyypillisi\u00e4 DC-MCB- ja DC-MCCB-malleja, joita k\u00e4ytet\u00e4\u00e4n arvioitaessa DC-katkaisijavaihtoehtoja.<\/figcaption><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Valinta tasavirtaisen minikatkaisijan (MCB) ja tasavirtaisen koteloidun katkaisijan (MCCB) v\u00e4lill\u00e4 ei ole niin yksinkertaista kuin se, ett\u00e4 MCB:t m\u00e4\u00e4ritelt\u00e4isiin \u201cpienille virroille\u201d ja MCCB:t \u201csuurille virroille\u201d.\u201d<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-group alignfull is-layout-constrained wp-container-core-group-is-layout-4f00fe7e wp-block-group-is-layout-constrained\" style=\"padding-top:64px;padding-right:24px;padding-bottom:64px;padding-left:24px\">\n\n\n<p class=\"wp-block-paragraph\">Tuo oikotie voi olla harhaanjohtava.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Nykyinen <a href=\"https:\/\/ritoks.com\/fi\/product-category\/dc-power-protection\/\">RITOKS DC-virransuojaus<\/a> Tuoteperheet osoittavat jo, miksi. Julkaistuihin DIN-kiskoon asennettaviin tasavirta-MCB-katkaisimiin kuuluu malleja, joiden virta-alue on 6\u201363 A, sek\u00e4 suurvirtaisia malleja, joiden virta-alue on 63\u2013250 A, kun taas nykyiseen koteloitujen tasavirta-katkaisimien tuoteperheeseen kuuluu 125 A:n ja 250 A:n runkomalleja.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Toisin sanoen pelkk\u00e4 virta-alue ei riit\u00e4 erottamaan luotettavasti MCB-katkaisinta MCCB-katkaisimesta.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">K\u00e4yt\u00e4nn\u00f6llisemm\u00e4ss\u00e4 tasavirtakatkaisimen valintaprosessissa otetaan huomioon seuraavat seikat:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>DC-j\u00e4rjestelm\u00e4n j\u00e4nnite<\/li>\n\n\n<li>k\u00e4ytt\u00f6virta<\/li>\n\n\n<li>vaadittu napojen lukum\u00e4\u00e4r\u00e4<\/li>\n\n\n<li>asennustapa<\/li>\n\n\n<li>saatavilla oleva tuotekokoonpano<\/li>\n\n\n<li>sovelluskontesti<\/li>\n\n\n<li>vahvistetut tiedot katkaisijan tarkasta mallista<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">T\u00e4ss\u00e4 oppaassa selitet\u00e4\u00e4n, miten DC-MCB- ja MCCB-vaihtoehtoja voidaan vertailla ilman, ett\u00e4 turvaudutaan yleisp\u00e4tev\u00e4\u00e4n virran kynnysarvoon.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"in-this-guide\">T\u00e4ss\u00e4 oppaassa<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"#quick-answer\">Pikavastaus: MCB vai MCCB?<\/a><\/li>\n\n\n<li><a href=\"#what-is-a-dc-mcb\">Mik\u00e4 on DC-tyyppinen MCB?<\/a><\/li>\n\n\n<li><a href=\"#what-is-a-dc-mccb\">Mik\u00e4 on DC-MCCB?<\/a><\/li>\n\n\n<li><a href=\"#why-current-alone-is-not-enough\">Miksi pelkk\u00e4 virta ei riit\u00e4<\/a><\/li>\n\n\n<li><a href=\"#selection-process\">K\u00e4yt\u00e4nn\u00f6nl\u00e4heinen valintaprosessi<\/a><\/li>\n\n\n<li><a href=\"#common-mistakes\">Yleisi\u00e4 valintavirheit\u00e4<\/a><\/li>\n\n\n<li><a href=\"#frequently-asked-questions\">Usein kysytyt kysymykset<\/a><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"quick-answer\">Pikavastaus: MCB vai MCCB?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Seuraavassa taulukossa on yhteenveto RITOKS-tuoteperheen nykyisest\u00e4 markkina-asemasta.<\/p>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table><thead><tr><th>Valintaperuste<\/th><th>DC-virrankatkaisija<\/th><th>DC-MCCB<\/th><\/tr><\/thead><tbody><tr><td>RITOKS-tuotteiden nykyinen kiinnitystapa<\/td><td>35 mm:n DIN-kisko<\/td><td>Paneeli \/ kiinte\u00e4 asennus<\/td><\/tr><tr><td>RITOKS:n nykyiset pylv\u00e4svaihtoehdot<\/td><td>1P \/ 2P mallista riippuen<\/td><td>2P nykyisess\u00e4 julkaistussa sukupuolijoukkossa<\/td><\/tr><tr><td>Julkaistuja ajankohtaisia esimerkkej\u00e4<\/td><td>6\u201363A- ja 63\u2013250A-tuoteperheet<\/td><td>125 A:n \/ 250 A:n kehykset<\/td><\/tr><tr><td>Julkaistuja j\u00e4nnitesesimerkkej\u00e4<\/td><td>12\u2013125 V, 500 V ja 500\u20131000 V DC -tuoteperheet<\/td><td>500 V \/ 1 000 V -mallit<\/td><\/tr><tr><td>P\u00e4\u00e4asiallinen valintamenetelm\u00e4<\/td><td>Noudata tarkasti s\u00e4hk\u00f6- ja asennusvaatimuksia<\/td><td>Noudata tarkasti s\u00e4hk\u00f6- ja asennusvaatimuksia<\/td><\/tr><tr><td>Voiko pelk\u00e4st\u00e4\u00e4n virta ratkaista valinnan?<\/td><td>Ei<\/td><td>Ei<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">T\u00e4m\u00e4 on tuoteperheiden vertailu, ei yleisp\u00e4tev\u00e4 tekninen s\u00e4\u00e4nt\u00f6.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Saatavilla olevista kaupallisista vaihtoehdoista l\u00f6yd\u00e4t lis\u00e4tietoja RITOKSista <a href=\"https:\/\/ritoks.com\/fi\/product-category\/dc-power-protection\/dc-circuit-breakers\/\">DC-katkaisijat<\/a> luokka.<\/p>\n\n\n\n<figure data-spectra-id=\"spectra-9bdf0c69-2c7d-4be2-b260-dce41f19155e\" class=\"wp-block-image size-full has-custom-border\" ><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/dc-breaker-product-family-comparison.jpg\" alt=\"Tyypillisi\u00e4 DC-katkaisimien tuoteryhmi\u00e4 aurinkos\u00e4hk\u00f6ty\u00f6p\u00f6yd\u00e4ll\u00e4\" class=\"wp-image-677\" width=\"1672\" height=\"941\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/dc-breaker-product-family-comparison.jpg 1672w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/dc-breaker-product-family-comparison-600x338.jpg 600w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/dc-breaker-product-family-comparison-300x169.jpg 300w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/dc-breaker-product-family-comparison-1024x576.jpg 1024w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/dc-breaker-product-family-comparison-768x432.jpg 768w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/dc-breaker-product-family-comparison-1536x864.jpg 1536w\" sizes=\"auto, (max-width: 1672px) 100vw, 1672px\" \/><figcaption class=\"wp-element-caption\">Esimerkki saatavilla olevista tasavirtakatkaisimien tuoteryhmist\u00e4; k\u00e4ytet\u00e4\u00e4n ainoastaan valinnan helpottamiseksi.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"what-is-a-dc-mcb\">Mik\u00e4 on DC-tyyppinen MCB?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">DC-pienikokoinen katkaisija (MCB) on kompakti virtapiirin suojalaite, jota toimitetaan yleens\u00e4 DIN-kiskoon asennettavina malleina.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">RITOKS DC MCB -tuotteisiin kuuluu t\u00e4ll\u00e4 hetkell\u00e4 useita eri tuoteryhmi\u00e4, eik\u00e4 niiss\u00e4 ole yht\u00e4 ainoaa nimellisarvoaluetta.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Esimerkiksi:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/ritoks.com\/fi\/products\/2p-dc-miniature-circuit-breaker-500-1000v-6-63a\/\">RTS-DC63-1000<\/a> \u2014 2P, 500\u20131000 V DC, 6\u201363 A, 35 mm:n DIN-kisko<\/li>\n\n\n<li>RTS-DC63-500 \u2014 2-napainen, 500 V DC, 6\u201363 A, 35 mm:n DIN-kisko<\/li>\n\n\n<li><a href=\"https:\/\/ritoks.com\/fi\/products\/high-current-dc-miniature-circuit-breaker-12-125v-63-250a\/\">RTS-DC250-125<\/a> \u2014 1P\/2P, 12\u2013125 V DC, 63\u2013250 A, 35 mm:n DIN-kisko<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">N\u00e4m\u00e4 esimerkit havainnollistavat t\u00e4rke\u00e4n valintaperiaatteen:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u201cMCB\u201d viittaa tuotteen rakenteeseen ja tuoteperheeseen; sit\u00e4 ei pid\u00e4 rajoittaa pelk\u00e4st\u00e4\u00e4n yhteen virranrajoitusarvoon.<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">K\u00e4ytett\u00e4viss\u00e4 oleva malli on viel\u00e4 tarkistettava todellisen tasavirt\u00e4j\u00e4rjestelm\u00e4n suhteen.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Lis\u00e4\u00e4 vaihtoehtoja l\u00f6yd\u00e4t kohdasta <a href=\"https:\/\/ritoks.com\/fi\/product-category\/dc-power-protection\/dc-circuit-breakers\/dc-miniature-circuit-breakers\/\">DC-pienoiskatkaisijat<\/a>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"what-is-a-dc-mccb\">Mik\u00e4 on DC-MCCB?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">DC-muovikoteloinen katkaisija (MCCB) on rakenteeltaan muovikoteloinen, ja se asennetaan yleens\u00e4 eri tavalla kuin DIN-kiskoon asennettava minikatkaisija.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">T\u00e4ll\u00e4 hetkell\u00e4 julkaistu RITOKS MCCB -tuoteperhe on seuraava:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/ritoks.com\/fi\/products\/2p-dc-molded-case-circuit-breaker-500-1000v-125-250a\/\"><strong>RTS-DCM250-1000<\/strong><\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Vahvistetut ja julkaistut ominaisuudet ovat seuraavat:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>2P-kokoonpano<\/li>\n\n\n<li>500 V \/ 1000 V DC -mallit<\/li>\n\n\n<li>125 A:n \/ 250 A:n kehykset<\/li>\n\n\n<li>paneeli \/ kiinte\u00e4 asennus<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">T\u00e4m\u00e4n vuoksi sen asennustapa eroaa nykyisist\u00e4 RITOKS-DIN-kiskolle asennettavista MCB-tuoteperheist\u00e4.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Nykyinen tuotevalikoima on kuitenkin osittain p\u00e4\u00e4llekk\u00e4inen RTS-DC250-125-MCB-tuoteperheen kanssa. Siksi pelkk\u00e4 kysymys:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u201cOnko virta suurempi kuin tietty arvo?\u201d<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">ei riit\u00e4 MCB:n ja MCCB:n v\u00e4lisen valinnan tekemiseen.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Katso nykyinen muovikoteloisten tuotteiden tuoteperhe kohdasta <a href=\"https:\/\/ritoks.com\/fi\/product-category\/dc-power-protection\/dc-circuit-breakers\/dc-molded-case-circuit-breakers\/\">DC-muovikoteloiset katkaisijat<\/a>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"why-current-alone-is-not-enough\">MCB vs. MCCB: Miksi pelkk\u00e4 virta ei riit\u00e4<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Yleinen valintaperuste on olettaa, ett\u00e4 MCB-katkaisimia k\u00e4ytet\u00e4\u00e4n aina tietyn virta-arvon alapuolella ja MCCB-katkaisimia sen yl\u00e4puolella.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Nykyinen RITOKS-tuotevalikoima osoittaa, miksi t\u00e4m\u00e4 l\u00e4hestymistapa on ep\u00e4luotettava.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">RTS-DC250-125-tyyppinen MCB-katkaisija kuuluu 35 mm:n DIN-kiskoon asennettavaan tuoteperheeseen, jonka virta-alue on 63 A \u2013 250 A.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">RTS-DCM250-1000-mallin MCCB-katkaisimessa on 125 A:n ja 250 A:n runkomallit.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">N\u00e4m\u00e4 alueet ovat osittain p\u00e4\u00e4llekk\u00e4isi\u00e4.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Siksi:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Se, ett\u00e4 vaaditaan 125 A:n tai 250 A:n virta, ei viel\u00e4 automaattisesti kerro, onko oikea tuotetyyppi MCB vai MCCB.<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">P\u00e4\u00e4t\u00f6ksess\u00e4 on sen sijaan otettava huomioon koko j\u00e4rjestelm\u00e4 ja asennusvaatimukset.<\/p>\n\n\n\n<figure data-spectra-id=\"spectra-cd0ee720-2d71-4751-95ec-dc73680bc06a\" class=\"wp-block-image size-full has-custom-border\" ><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/dc-mcb-mccb-form-factor-comparison.jpg\" alt=\"DIN-kiskoon asennettavan tasavirta-MCB:n ja koteloidun tasavirta-MCCB:n vertailu aurinkos\u00e4hk\u00f6n tasavirtajakelukaapissa\" class=\"wp-image-676\" width=\"1672\" height=\"941\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/dc-mcb-mccb-form-factor-comparison.jpg 1672w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/dc-mcb-mccb-form-factor-comparison-600x338.jpg 600w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/dc-mcb-mccb-form-factor-comparison-300x169.jpg 300w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/dc-mcb-mccb-form-factor-comparison-1024x576.jpg 1024w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/dc-mcb-mccb-form-factor-comparison-768x432.jpg 768w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/dc-mcb-mccb-form-factor-comparison-1536x864.jpg 1536w\" sizes=\"auto, (max-width: 1672px) 100vw, 1672px\" \/><figcaption class=\"wp-element-caption\">Esimerkki vertailusta, jossa tarkastellaan DIN-kiskoon asennettavan DC-MCB-katkaisijan ja koteloidun DC-MCCB-katkaisijan asennustapoja tasavirtas\u00e4ilytyskaapissa.<\/figcaption><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">1. Aloita tasavirtaj\u00e4rjestelm\u00e4n j\u00e4nnitteest\u00e4<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Ensimm\u00e4isen kysymyksen pit\u00e4isi olla:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Mink\u00e4 suuruista tasaj\u00e4nnitett\u00e4 katkaisijan on kestett\u00e4v\u00e4?<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Nykyiset RITOKS-MCB-tuoteperheet kattavat hyvin erilaisia j\u00e4nniteolosuhteita.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Esimerkiksi:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>yksi sarja on tarkoitettu k\u00e4ytett\u00e4v\u00e4ksi 12\u2013125 V:n tasaj\u00e4nnitteell\u00e4<\/li>\n\n\n<li>toinen 500 V:n tasavirralle<\/li>\n\n\n<li>toinen 500\u20131000 V DC:lle<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Nykyiseen MCCB-tuoteperheeseen kuuluu my\u00f6s 500 V:n ja 1000 V:n tasavirta-mallit.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">T\u00e4m\u00e4 tarkoittaa, ett\u00e4 kaksi katkaisijaa, joiden nimellisvirrat ovat samankokoisia, voivat silti kuulua hyvin erilaisiin j\u00e4rjestelm\u00e4j\u00e4nnitesovelluksiin.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u00c4l\u00e4 valitse katkaisijaa pelk\u00e4st\u00e4\u00e4n nimivirran perusteella ja oleta sitten, ett\u00e4 my\u00f6s j\u00e4nnitevaatimukset t\u00e4yttyv\u00e4t.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Tarkka malli ja kokoonpano on tarkistettava.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">2. Varmista tarvittava k\u00e4ytt\u00f6virta<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Virta on edelleen t\u00e4rke\u00e4 valintaperuste, mutta se on vain yksi osa p\u00e4\u00e4t\u00f6st\u00e4.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Esimerkiksi nykyisiin RITOKS MCB -tuoteperheisiin kuuluvat:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>6\u201363A-vaihtoehdot<\/li>\n\n\n<li>63\u2013250 A:n vaihtoehdot<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">nykyiseen MCCB-tuoteperheeseen kuuluvat:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>125A-runko<\/li>\n\n\n<li>250A-runko<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">T\u00e4m\u00e4 p\u00e4\u00e4llekk\u00e4isyys tarkoittaa, ett\u00e4 nykyarvo kaventaa ehdokastuotteiden joukkoa, mutta ei sin\u00e4ns\u00e4 m\u00e4\u00e4r\u00e4\u00e4 katkaisijan rakennetta.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Oikean valinnan tulisi perustua aina kyseisen mallin tarkkaan dokumentaatioon.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">3. Tarkista napojen lukum\u00e4\u00e4r\u00e4<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Pylv\u00e4\u00e4n rakenne voi my\u00f6s vaikuttaa siihen, mik\u00e4 tuoteperhe on sopivin.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">T\u00e4ll\u00e4 hetkell\u00e4 julkaistuja RITOKS-esimerkkej\u00e4 ovat muun muassa:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>2P-MCB-tuoteperheet<\/li>\n\n\n<li>1P\/2P-matalaj\u00e4nnitteisten suurvirtaisten MCB-tuoteperhe<\/li>\n\n\n<li>2P MCCB -tuoteperhe<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Siksi tarvittava napojen lukum\u00e4\u00e4r\u00e4 tulisi m\u00e4\u00e4ritt\u00e4\u00e4 ennen mallin valintaa.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u00c4l\u00e4 oleta, ett\u00e4 kaikkia MCB- tai MCCB-tuoteperheit\u00e4 on saatavilla samassa napakokoonpanossa.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">4. Ota huomioon kiinnitystapa<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">T\u00e4m\u00e4 on yksi selkeimmist\u00e4 k\u00e4yt\u00e4nn\u00f6n eroista nykyisess\u00e4 RITOKS-tuotevalikoimassa.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Nykyiset DC-MCB-tuoteperheet<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Julkaistuissa MCB-esimerkeiss\u00e4 k\u00e4ytet\u00e4\u00e4n:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>35 mm:n DIN-kiskoon asennus<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">T\u00e4m\u00e4 rakenne liitet\u00e4\u00e4n yleens\u00e4 kompaktiin modulaariseen asennukseen sopiviin s\u00e4hk\u00f6koteloihin.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Nykyinen DC-MCCB-tuoteperhe<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Julkaistussa MCCB-esimerkiss\u00e4 k\u00e4ytet\u00e4\u00e4n:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>paneeli \/ kiinte\u00e4 asennus<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">T\u00e4m\u00e4 luo t\u00e4ysin erilaisen asennusmuodon.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Joten kun projektissa on jo m\u00e4\u00e4ritelty:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>DIN-kiskoon asennettavat modulaariset laitteet<\/li>\n\n\n<li>paneeliin asennettavat muovikoteloiset laitteet<\/li>\n\n\n<li>tietty suojarakenteen rakenne<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Asennustapa voi heti kaventaa valinnanvaraa.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">T\u00e4m\u00e4 on usein hy\u00f6dyllisemp\u00e4\u00e4 kuin yritt\u00e4\u00e4 m\u00e4\u00e4ritt\u00e4\u00e4 yleisp\u00e4tev\u00e4\u00e4 nykytilan rajaa.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">5. Vertaa tuotteen tarkkaa kokoonpanoa<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u201cMCB\u201d ja \u201cMCCB\u201d ovat tuoteryhmien nimityksi\u00e4.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Niiss\u00e4 ei kerrota tietyn katkaisijan kaikkia ominaisuuksia.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Varmista ennen tilaamista tarkka malli ja asiaankuuluva julkaistu kokoonpano.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Hankintak\u00e4yt\u00e4nt\u00f6jen tarkastelussa tulisi v\u00e4hint\u00e4\u00e4n selvitt\u00e4\u00e4 seuraavat seikat:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Tasaj\u00e4nnite<\/li>\n\n\n<li>nykyinen vaatimus<\/li>\n\n\n<li>pylv\u00e4sasettelu<\/li>\n\n\n<li>kiinnitystapa<\/li>\n\n\n<li>tuotteen tarkka malli<\/li>\n\n\n<li>sovelluskontesti<\/li>\n\n\n<li>muut vaaditut, dokumentoidut ominaisuudet<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Jos parametria ei ole vahvistettu mallin dokumentaatiossa, sit\u00e4 ei pid\u00e4 olettaa saman yleisen luokan toisen katkaisijan perusteella.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"mcb-vs-mccb-at-a-glance\">DC-MCB ja MCCB \u2013 vertailu yhdell\u00e4 silm\u00e4yksell\u00e4<\/h2>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table><thead><tr><th>Kysymys<\/th><th>MCB:n huomioon ottaminen<\/th><th>MCCB:n huomioon ottaminen<\/th><\/tr><\/thead><tbody><tr><td>Tarvitsenko DIN-kiskoasennuksen?<\/td><td>Nykyisiss\u00e4 RITOKS-MCB-tuoteperheiss\u00e4 k\u00e4ytet\u00e4\u00e4n 35 mm:n DIN-kiskoa<\/td><td>T\u00e4ll\u00e4 hetkell\u00e4 markkinoilla olevat MCCB-laitteet asennetaan paneeliin tai kiinte\u00e4sti<\/td><\/tr><tr><td>Tarvitsenko 1P:t\u00e4?<\/td><td>Saatavana nykyisess\u00e4 RTS-DC250-125-tuoteperheess\u00e4<\/td><td>T\u00e4ll\u00e4 hetkell\u00e4 julkaistu MCCB-tuoteperhe on 2P<\/td><\/tr><tr><td>Onko virta yli 63 A?<\/td><td>Nykyinen RITOKS-yl\u00e4virtakytkinperhe kattaa jopa 250 A:n virran<\/td><td>Nykyiseen MCCB-tuoteperheeseen kuuluu my\u00f6s 125 A\/250 A:n mallit<\/td><\/tr><tr><td>Tarvitsenko 500 V:n vai 1000 V:n tasavirtaa?<\/td><td>Saatavana tietyiss\u00e4 MCB-tuoteperheiss\u00e4<\/td><td>Saatavana nykyisess\u00e4 MCCB-tuoteperheess\u00e4<\/td><\/tr><tr><td>Voinko valita pelk\u00e4st\u00e4\u00e4n virran perusteella?<\/td><td>Ei<\/td><td>Ei<\/td><\/tr><tr><td>Pit\u00e4isik\u00f6 minun tarkistaa tarkka malli?<\/td><td>Kyll\u00e4<\/td><td>Kyll\u00e4<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">T\u00e4rkein johtop\u00e4\u00e4t\u00f6s ei ole se, ett\u00e4 jokin tietty katkaisintyyppi olisi \u201cparempi\u201d.\u201d<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">T\u00e4rke\u00e4 kysymys on:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Mik\u00e4 rakenne ja mik\u00e4 tarkka malli t\u00e4ytt\u00e4v\u00e4t t\u00e4m\u00e4n tasavirt\u00e4j\u00e4rjestelm\u00e4n s\u00e4hk\u00f6- ja asennusvaatimukset?<\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Esimerkki 1: Kompakti DIN-kiskoon asennettava tasavirtasuojaus<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Oletetaan, ett\u00e4 projektissa tarvitaan:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>DIN-kiskoon asennettava katkaisija<\/li>\n\n\n<li>vakiintunut tasaj\u00e4nnite<\/li>\n\n\n<li>nykyinen vaatimus saatavilla olevan mallivalikoiman puitteissa<\/li>\n\n\n<li>tuettu pylv\u00e4srakenne<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Siin\u00e4 tapauksessa nykyiset tasavirtaiset MCB-tuoteperheet saattavat olla ensimm\u00e4inen tutkittava tuoteryhm\u00e4, koska julkaistuissa RITOKS-MCB-esimerkeiss\u00e4 k\u00e4ytet\u00e4\u00e4n 35 mm:n DIN-kiskoa.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Esimerkiksi RTS-DC63-1000-tuoteperhe tarjoaa:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>2P<\/li>\n\n\n<li>500\u20131000 V DC<\/li>\n\n\n<li>6\u201363A<\/li>\n\n\n<li>35 mm:n DIN-kisko<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">T\u00e4m\u00e4 ei tarkoita, ett\u00e4 se sopisi automaattisesti jokaiseen j\u00e4rjestelm\u00e4\u00e4n, joka t\u00e4ytt\u00e4\u00e4 n\u00e4m\u00e4 nimellisarvot. Tarkka k\u00e4ytt\u00f6tarkoitus ja tuotetiedot on viel\u00e4 vahvistettava.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Esimerkki 2: Suurvirtaiset DIN-kiskoasennukset<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Suurempi virrankulutus ei tarkoita automaattisesti MCCB:n k\u00e4ytt\u00f6\u00e4.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">RTS-DC250-125 on markkinoille tuotu DC-MCB-tuoteperhe, johon kuuluvat:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>1P \/ 2P<\/li>\n\n\n<li>12\u2013125 V DC<\/li>\n\n\n<li>63\u2013250 A<\/li>\n\n\n<li>35 mm:n DIN-kisko<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">T\u00e4m\u00e4 on t\u00e4rke\u00e4 esimerkki, koska se kumottaa suoraan k\u00e4sityksen, ett\u00e4 jokaisessa suurvirtaisessa tasavirtasovelluksessa olisi automaattisesti siirrytt\u00e4v\u00e4 valukoteloiseen katkaisimeen.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">J\u00e4rjestelm\u00e4n j\u00e4nnite ja asennustapa ovat edelleen t\u00e4rkeit\u00e4.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Esimerkki 3: Paneeliin asennettavan muovikotelon vaatimukset<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Jos hankkeessa tarvitaan muovikoteloista katkaisijaa, joka on tarkoitettu asennettavaksi jakorasiin tai kiinte\u00e4sti, RTS-DCM250-1000-tuoteperhe on sopiva vaihtoehto.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Sen julkistettu kokoonpano sis\u00e4lt\u00e4\u00e4 seuraavat osat:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>2P<\/li>\n\n\n<li>500 V \/ 1 000 V -mallit<\/li>\n\n\n<li>125 A:n \/ 250 A:n kehykset<\/li>\n\n\n<li>paneeli \/ kiinte\u00e4 asennus<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">J\u00e4lleen kerran lopullisen p\u00e4\u00e4t\u00f6ksen tulisi perustua nimenomaan valittuun varianttiin ja vahvistettuihin tuotetietoihin eik\u00e4 pelk\u00e4st\u00e4\u00e4n tuoteperheen nimeen.<\/p>\n\n\n\n<figure data-spectra-id=\"spectra-3e342bfa-f4b0-4037-8560-d44abef370d4\" class=\"wp-block-image size-full has-custom-border\" ><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/dc-circuit-breaker-application-context.jpg\" alt=\"Tasavirta-katkaisimien k\u00e4ytt\u00f6kohteet aurinkos\u00e4hk\u00f6isten akkuvarastointij\u00e4rjestelmien ja teollisten tasavirran jakeluj\u00e4rjestelmien yhteydess\u00e4\" class=\"wp-image-674\" width=\"1672\" height=\"941\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/dc-circuit-breaker-application-context.jpg 1672w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/dc-circuit-breaker-application-context-600x338.jpg 600w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/dc-circuit-breaker-application-context-300x169.jpg 300w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/dc-circuit-breaker-application-context-1024x576.jpg 1024w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/dc-circuit-breaker-application-context-768x432.jpg 768w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/dc-circuit-breaker-application-context-1536x864.jpg 1536w\" sizes=\"auto, (max-width: 1672px) 100vw, 1672px\" \/><figcaption class=\"wp-element-caption\">Esimerkkej\u00e4 tasavirta-ymp\u00e4rist\u00f6ist\u00e4, joissa on aurinkos\u00e4hk\u00f6j\u00e4rjestelmi\u00e4, akkuvarastoja ja teollisuuden tasavirtaverkkoja.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"selection-process\">K\u00e4yt\u00e4nn\u00f6nl\u00e4heinen menetelm\u00e4 tasavirtakatkaisijan valintaan<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Perustellumpi valintaprosessi n\u00e4ytt\u00e4\u00e4 t\u00e4lt\u00e4:<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Vaihe 1 \u2014 M\u00e4\u00e4rit\u00e4 tasaj\u00e4nnite<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Tarkista j\u00e4rjestelm\u00e4n todellinen j\u00e4nnite ennen mallien vertailua.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Vaihe 2 \u2014 M\u00e4\u00e4rit\u00e4 k\u00e4ytt\u00f6virta<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">K\u00e4yt\u00e4 vaadittua virtaa rajataksesi saatavilla olevia tuoteryhmi\u00e4.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Vaihe 3 \u2014 M\u00e4\u00e4rit\u00e4 pylv\u00e4svaatimukset<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Selvit\u00e4, vaatiiko piiri konfiguraatiota, joka on t\u00e4ll\u00e4 hetkell\u00e4 saatavilla valitusta tuoteperheest\u00e4.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Vaihe 4 \u2014 M\u00e4\u00e4rit\u00e4 asennustapa<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Kysy, onko asennus suunniteltu seuraavien seikkojen perusteella:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>35 mm:n DIN-kisko<\/li>\n\n\n<li>paneeli \/ kiinte\u00e4 asennus<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Vaihe 5 \u2014 Vertaa ehdokasmallit<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Vertaa vain tuotteita, joiden ilmoitetut j\u00e4nnite-, virta-, napam\u00e4\u00e4r\u00e4- ja asennuskonfiguraatiot vastaavat projektin vaatimuksia.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Vaihe 6 \u2014 Tarkista asiakirjojen oikeellisuus<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u00c4l\u00e4 sovella yhden mallin s\u00e4hk\u00f6isi\u00e4 ominaisuuksia, lis\u00e4varusteita tai suorituskykyv\u00e4itteit\u00e4 toiseen malliin.<\/p>\n\n\n\n<figure data-spectra-id=\"spectra-2f80409d-fca5-4f54-9a29-31bb03d20b0b\" class=\"wp-block-image size-full has-custom-border\" ><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/dc-circuit-breaker-selection-flow.jpg\" alt=\"DC-katkaisijan valintaprosessi, jossa otetaan huomioon j\u00e4nnite, virta, napam\u00e4\u00e4r\u00e4, asennustapa ja tarkka mallitiedon tarkistus\" class=\"wp-image-673\" width=\"1672\" height=\"941\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/dc-circuit-breaker-selection-flow.jpg 1672w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/dc-circuit-breaker-selection-flow-600x338.jpg 600w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/dc-circuit-breaker-selection-flow-300x169.jpg 300w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/dc-circuit-breaker-selection-flow-1024x576.jpg 1024w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/dc-circuit-breaker-selection-flow-768x432.jpg 768w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/dc-circuit-breaker-selection-flow-1536x864.jpg 1536w\" sizes=\"auto, (max-width: 1672px) 100vw, 1672px\" \/><figcaption class=\"wp-element-caption\">K\u00e4yt\u00e4nn\u00f6llinen tasavirtakatkaisijan valintaprosessi, joka perustuu j\u00e4nnitteeseen, virtaan, napam\u00e4\u00e4r\u00e4\u00e4n, asennustapaan ja tarkan mallin tarkistamiseen.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"common-mistakes\">Yleisi\u00e4 virheit\u00e4 MCB- ja MCCB-laitteiden valinnassa<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Kiinte\u00e4n virrankynnyksen k\u00e4ytt\u00f6<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">T\u00e4m\u00e4 on t\u00e4rkein virhe, jota on v\u00e4ltett\u00e4v\u00e4.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">RITOKS:n nykyisess\u00e4 tuotevalikoimassa on jo MCB- ja MCCB-tuotteita, joiden virta-arvot ovat osittain p\u00e4\u00e4llekk\u00e4isi\u00e4.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">DC-j\u00e4nnitteen huomioimatta j\u00e4tt\u00e4minen<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Vaikka katkaisija t\u00e4ytt\u00e4isikin virta-vaatimukset, se voi silti kuulua v\u00e4\u00e4r\u00e4\u00e4n j\u00e4nniteryhm\u00e4\u00e4n.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Asennustavan huomiotta j\u00e4tt\u00e4minen<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">DIN-kiskoon asennettava MCB-katkaisija ja paneeliin asennettava MCCB-katkaisija edellytt\u00e4v\u00e4t erilaisia asennustapoja.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Olettaen, ett\u00e4 jokaisella perheell\u00e4 on samat pylv\u00e4\u00e4t<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Nykyiset kokoonpanot vaihtelevat tuoteperheitt\u00e4in.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Oletetaan vahvistamaton huippukapasiteetti<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Katkaisukapasiteettitiedot on sidottava tarkasti vahvistettuun malliin tai varianttiin. Niit\u00e4 ei pid\u00e4 yleist\u00e4\u00e4 koskemaan koko MCB- ja MCCB-tuoteperhett\u00e4.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Matkan toimintojen tai lis\u00e4varusteiden oletukset<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u00c4l\u00e4 oleta, ett\u00e4 laitteessa on s\u00e4\u00e4dett\u00e4v\u00e4t laukaisuarvot, laukaisuk\u00e4yr\u00e4t, shunt-laukaisutoiminnot tai lis\u00e4varusteita, ellei niit\u00e4 ole nimenomaisesti vahvistettu juuri hankittavalle katkaisijalle.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Valinta pelk\u00e4st\u00e4\u00e4n ulkon\u00e4\u00f6n perusteella<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Katkaisijan ulkon\u00e4k\u00f6 ei riit\u00e4 osoittamaan sen sopivuutta tiettyyn tasavirtapiiriin.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">MCB- ja MCCB-laitteiden rooli tasavirran suojauksessa<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Virtakatkaisijat ovat vain yksi osa laajempaa tasavirran suojausj\u00e4rjestelm\u00e4\u00e4.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">J\u00e4rjestelm\u00e4n rakenteesta riippuen muihin toimintoihin voivat kuulua:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/ritoks.com\/fi\/dc-fuse-vs-dc-circuit-breaker\/\">sulakesuojaus<\/a><\/li>\n\n\n<li>manuaalinen erist\u00e4minen<\/li>\n\n\n<li>ylij\u00e4nnitesuoja<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Yleiskatsaus n\u00e4iden toimintojen eroista l\u00f6ytyy t\u00e4\u00e4lt\u00e4:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/ritoks.com\/fi\/dc-protection-devices-explained\/\"><strong>DC-suojalaitteiden selitys: katkaisijat, sulakkeet, erottimet ja ylij\u00e4nnitesuojat (SPD)<\/strong><\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Kyseisess\u00e4 oppaassa selitet\u00e4\u00e4n, miksi katkaisijaa, sulaketta, eristint\u00e4 ja ylij\u00e4nnitesuojaa ei pid\u00e4 automaattisesti pit\u00e4\u00e4 kesken\u00e4\u00e4n vaihdettavissa olevina laitteina.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"frequently-asked-questions\">Usein kysytyt kysymykset<\/h2>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>K\u00e4ytet\u00e4\u00e4nk\u00f6 MCCB:t\u00e4 aina suuremmille virroille kuin MCB:t\u00e4?<\/summary>\n<p class=\"wp-block-paragraph\">Ei. Nykyiseen RITOKS-tuotesarjaan kuuluu DIN-kiskoon asennettavien tasavirta-MCB-laitteiden tuoteperhe, jonka nimellisvirta-alue on 63\u2013250 A, sek\u00e4 tasavirta-MCCB-laitteiden tuoteperhe, jossa on 125 A:n ja 250 A:n kotelokoot. Niiden virta-alueet ovat osittain p\u00e4\u00e4llekk\u00e4isi\u00e4, joten valintaa ei voida tehd\u00e4 pelk\u00e4st\u00e4\u00e4n virran perusteella.<\/p>\n<\/details>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Mik\u00e4 on selkein ero nykyisten RITOKS-MCB- ja MCCB-tuoteperheiden v\u00e4lill\u00e4?<\/summary>\n<p class=\"wp-block-paragraph\">Selkein vahvistettu ero on kiinnitystapa. Nykyisiss\u00e4 RITOKS MCB -malleissa k\u00e4ytet\u00e4\u00e4n 35 mm:n DIN-kiskoa, kun taas julkaistussa MCCB-tuoteperheess\u00e4 k\u00e4ytet\u00e4\u00e4n paneeli- tai kiinte\u00e4\u00e4 kiinnityst\u00e4.<\/p>\n<\/details>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Voinko valita MCB:n ja MCCB:n v\u00e4lill\u00e4 pelk\u00e4st\u00e4\u00e4n j\u00e4nnitteen perusteella?<\/summary>\n<p class=\"wp-block-paragraph\">Ei. J\u00e4nnite on yksi valintakriteeri. My\u00f6s virta, napam\u00e4\u00e4r\u00e4, asennustapa, mallin tarkka kokoonpano ja k\u00e4ytt\u00f6vaatimukset on tarkistettava.<\/p>\n<\/details>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Tarvitseeko 250 A:n tasavirtapiiri automaattisesti MCCB-katkaisimen?<\/summary>\n<p class=\"wp-block-paragraph\">Ei v\u00e4ltt\u00e4m\u00e4tt\u00e4. RITOKS valmistaa t\u00e4ll\u00e4 hetkell\u00e4 DC-tyyppisi\u00e4 MCB-katkaisimia, joiden nimellisvirta ulottuu 250 A:iin, sek\u00e4 MCCB-katkaisimia, joiden runko on 250 A:n kokoinen. Oikea valinta riippuu s\u00e4hk\u00f6- ja asennusvaatimuksista kokonaisuudessaan.<\/p>\n<\/details>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Soveltuvatko kaikki tasavirtaiset MCB-katkaisijat samoihin k\u00e4ytt\u00f6kohteisiin?<\/summary>\n<p class=\"wp-block-paragraph\">Ei. T\u00e4ll\u00e4 hetkell\u00e4 markkinoilla olevien MCB-tuoteperheiden j\u00e4nnite-, virta- ja napam\u00e4\u00e4r\u00e4asetukset vaihtelevat. Sopivuus on varmistettava kunkin mallin osalta erikseen.<\/p>\n<\/details>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Pit\u00e4isik\u00f6 katkaisukapasiteettia verrata katkaisinta valittaessa?<\/summary>\n<p class=\"wp-block-paragraph\">Se voi olla t\u00e4rke\u00e4 tuotteen ominaisuus, mutta arvon on perustuttava kyseisen mallin tai variantin osalta vahvistettuun dokumentaatioon. Yhden tuotteen arvoa ei saa soveltaa koko MCB- tai MCCB-tuoteperheeseen.<\/p>\n<\/details>\n\n\n\n<div class=\"wp-block-group has-ast-global-color-5-color has-ast-global-color-2-background-color has-text-color has-background is-layout-constrained wp-container-core-group-is-layout-737f6912 wp-block-group-is-layout-constrained\" style=\"border-radius:6px;margin-top:48px;padding-top:40px;padding-right:32px;padding-bottom:40px;padding-left:32px\">\n<h2 class=\"wp-block-heading\">Tarvitsetko apua DC-MCB- tai MCCB-katkaisijan valinnassa?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">RITOKS tarjoaa sek\u00e4 DC-miniatyyri-katkaisimien ett\u00e4 DC-koteloitujen katkaisimien tuotevalikoimia.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Toimituskysely\u00e4 varten ilmoita seuraavat tiedot:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>DC-j\u00e4rjestelm\u00e4n j\u00e4nnite<\/li>\n\n\n<li>k\u00e4ytt\u00f6virta<\/li>\n\n\n<li>tarvittavat pylv\u00e4\u00e4t<\/li>\n\n\n<li>suositeltu asennustapa<\/li>\n\n\n<li>hakemus<\/li>\n\n\n<li>kaikki vaaditut dokumentoidut ominaisuudet<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">RITOKS voi t\u00e4m\u00e4n j\u00e4lkeen verrata tiedustelua t\u00e4ll\u00e4 hetkell\u00e4 saatavilla oleviin tuoteryhmiin ja vahvistettuihin mallitietoihin.<\/p>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-ast-global-color-0-background-color has-background wp-element-button\" href=\"https:\/\/ritoks.com\/fi\/product-category\/dc-power-protection\/dc-circuit-breakers\/\">Katso DC-katkaisijat \u2192<\/a><\/div>\n\n\n\n<div class=\"wp-block-button is-style-outline is-style-outline--1\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/ritoks.com\/fi\/contact-us\/\">Ota yhteytt\u00e4 RITOKSiin \u2192 Pyyd\u00e4 tarjous<\/a><\/div>\n<\/div>\n<\/div>\n\n\n<\/div>","protected":false},"excerpt":{"rendered":"<p>How to Choose a DC Circuit Breaker: MCB vs MCCB Choosing between a DC miniature circuit breaker (MCB) and a [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"no-sidebar","site-content-layout":"page-builder","ast-site-content-layout":"full-width-container","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"disabled","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"disabled","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"disabled","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ritoks_resource_detail_renderer":null,"ritoks_resource_product_cat_term_id":0,"footnotes":""},"categories":[64],"tags":[],"class_list":["post-668","post","type-post","status-publish","format-standard","hentry","category-circuit-protection"],"acf":[],"spectra_blocks_featured_image_url":null,"spectra_blocks_author_info":{"display_name":"RITOKS","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/6d7d0fc73468198f994ab13ef6eb6558c53b6ed1ad86364d5165efe8bdf8eb4a?s=96&d=mm&r=g","author_link":"https:\/\/ritoks.com\/fi\/author\/dazzlingwqbgmail-com\/","description":""},"_links":{"self":[{"href":"https:\/\/ritoks.com\/fi\/wp-json\/wp\/v2\/posts\/668","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ritoks.com\/fi\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ritoks.com\/fi\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ritoks.com\/fi\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/ritoks.com\/fi\/wp-json\/wp\/v2\/comments?post=668"}],"version-history":[{"count":7,"href":"https:\/\/ritoks.com\/fi\/wp-json\/wp\/v2\/posts\/668\/revisions"}],"predecessor-version":[{"id":1450,"href":"https:\/\/ritoks.com\/fi\/wp-json\/wp\/v2\/posts\/668\/revisions\/1450"}],"wp:attachment":[{"href":"https:\/\/ritoks.com\/fi\/wp-json\/wp\/v2\/media?parent=668"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ritoks.com\/fi\/wp-json\/wp\/v2\/categories?post=668"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ritoks.com\/fi\/wp-json\/wp\/v2\/tags?post=668"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}