Power Semiconductor Modules · RTX-SSR-H
RTX-SSR-H Single-Phase Solid-State Relays with Integrated Heatsink
DIN-rail solid-state relays with integrated heatsink for configured single-phase AC load control. The RTX-SSR-H reference maps to a 480 VAC, 40 A, 4–32 VDC zero-crossing configuration; confirm the exact variant and thermal requirements before order.
लोड वोल्टेज480 VAC
लोड धारा40 A
इनपुट नियंत्रित करें4–32 VDC
SwitchingZero-crossing configuration
उत्पाद अवलोकन
DIN-rail solid-state relays with integrated heatsink for configured single-phase AC load control. The RTX-SSR-H reference maps to a 480 VAC, 40 A, 4–32 VDC zero-crossing configuration; confirm the exact variant and thermal requirements before order.
मुख्य विशेषताएँ
- Integrated heatsink for configured single-phase AC load switching
- 480 VAC load-voltage reference with 40 A current rating
- 4–32 VDC control input
- Zero-crossing configuration; variant confirmation required
उपलब्ध मॉडल / विन्यास
Use these RITOKS configuration references for enquiry; confirm the exact specification before ordering.
| RTX-SSR-H | 480 VAC / 40 A / 4–32 VDC / zero-crossing |
|---|---|
| RTX-SSR-H-Z | Zero-crossing variant; confirm thermal requirements |
| RTX-SSR-H-R | Random-turn-on variant by configuration |
तकनीकी विनिर्देश
| लोड वोल्टेज | 480 VAC |
|---|---|
| लोड धारा | 40 A |
| इनपुट नियंत्रित करें | 4–32 VDC |
| Switching | Zero-crossing configuration |
| तापीय प्रबंधन | Integrated heatsink; confirm derating and airflow for the selected load |
| स्थापना | DIN-rail or panel installation according to the selected housing |
| लोड का प्रकार | Configured single-phase AC load control |
| Variant | Confirm zero-crossing or random-turn-on requirement before order |
आवेदन
AI-generated conceptual application context. Confirm equipment fit, installation conditions and circuit requirements for the selected configuration.

Resistive heating loads
Switch configured single-phase heaters after current, thermal and duty-cycle review.
Panel-mounted AC loads
Use the integrated heatsink housing where enclosure airflow and derating are confirmed.
Industrial automation cabinets
Coordinate the 4–32 VDC control signal with the selected zero-crossing variant.
चयन के लिए पुष्टि हेतु जानकारी
- Load voltage, load current and AC load type
- Control input and switching mode
- Heatsink airflow, mounting and derating conditions
- Required variant, quantity and destination
अक्सर पूछे जाने वाले प्रश्न
What information is needed for a quotation?
Please include the exact configuration reference, quantity, destination and documentation requirements.
कोटेशन का अनुरोध करें
सटीक मॉडल, आवश्यक रेटिंग, मात्रा और गंतव्य भेजें। हम कोटेशन से पहले उपलब्धता और दस्तावेज़ीकरण की पुष्टि करेंगे।.