Ajukan Pertanyaan Sekarang
RITOKS RTX-ACT50 through-hole AC current transducer with 4-20mA output on a white background

Electrical Measurement & Monitoring · RTX-ACT

RTX-ACT Through-Hole AC Current Transducers 4-20mA

DIN-rail AC current transducers with a through-hole sensing window and a 4–20mA output, in classic and high-accuracy versions from 0–5A to 0–200A.

MasukanAC 0–5A to 0–200A

Hasil4–20mA

PemasanganRel DIN

Berat0.15 kg

Gambaran Umum Produk

RTX-ACT transducers convert AC current passed through the window into a 4–20mA signal for PLCs and meters. The classic line covers 0–5A to 0–200A; the high-accuracy line covers 0–5A to 0–100A, with 5A and 10A versions wired to terminals. Supply voltage and accuracy must be confirmed by version.

Fitur Utama

  • Through-hole window for primary conductor
  • 4–20mA analog output
  • Classic and high-accuracy lines
  • Pemasangan pada rel DIN

Model / Konfigurasi yang Tersedia

Use these RITOKS configuration references for enquiry; confirm the exact specification before ordering.

Referensi RITOKSLineMasukanKoneksi
RTX-ACT5ClassicAC 0–5AThrough-hole
RTX-ACT10ClassicAC 0–10AThrough-hole
RTX-ACT20ClassicAC 0–20AThrough-hole
RTX-ACT30ClassicAC 0–30AThrough-hole
RTX-ACT50ClassicAC 0–50AThrough-hole
RTX-ACT100ClassicAC 0–100AThrough-hole
RTX-ACT200ClassicAC 0–200AThrough-hole
RTX-ACT-H5High accuracyAC 0–5ATerminal wired
RTX-ACT-H10High accuracyAC 0–10ATerminal wired
RTX-ACT-H20High accuracyAC 0–20AThrough-hole
RTX-ACT-H30High accuracyAC 0–30AThrough-hole
RTX-ACT-H50High accuracyAC 0–50AThrough-hole
RTX-ACT-H100High accuracyAC 0–100AThrough-hole

Spesifikasi Teknis

Jenis produkTransduser arus bolak-balik
MasukanAC 0–5A to 0–200A by model
Hasil4–20mA
PemasanganRel DIN
Berat0.15 kg
Supply and accuracyNot published per model; confirm with ritoks before ordering

Aplikasi

AI-generated conceptual application context. Confirm equipment fit, installation conditions and circuit requirements for the selected configuration.

AI-generated scene of a through-hole AC current transducer on a DIN rail beside a PLC

PLC energy monitoring

Feed motor or feeder current to PLC analog inputs.

Pump and fan supervision

Detect running, overload and dry-run states from current.

Panel meters

Drive 4–20mA indicators for branch circuit current.

Informasi yang Perlu Dipastikan untuk Proses Seleksi

  • Input range and conductor size
  • Classic or high-accuracy line
  • Auxiliary supply voltage
  • Required accuracy and quantity

Pertanyaan yang Sering Diajukan

What supply voltage does it need?

Supply is not published per model. Confirm it before ordering.

Which models are wired instead of through-hole?

The high-accuracy 5A and 10A models connect by terminals; others use the through-hole window.

Minta Penawaran Harga

Berikan informasi mengenai model yang tepat, spesifikasi yang dibutuhkan, jumlah, dan tujuan pengiriman. Kami akan mengonfirmasi ketersediaan dan dokumen yang diperlukan sebelum memberikan penawaran harga.

Minta Informasi Produk & Harga

Kirimkan nomor model, spesifikasi, jumlah, dan rincian tujuan pengiriman. Kami akan memastikan ketersediaannya sebelum menyusun penawaran harga.

Gulir ke Atas