Molded Case Circuit Breakers · RTX-M1
RTX-M1 AC Molded Case Circuit Breakers 16A-800A, 3P/4P
AC molded case circuit breakers across six frames from 63A to 800A, 3P and 4P, with frame-specific breaking capacities from 18kA to 50kA at AC380V.
Tegangan pengenalAC380V
Arus pengenal16A–800A
Frames63 / 100 / 225 / 400 / 630 / 800A
Kapasitas puncak18kA–50kA by rating
Gambaran Umum Produk
The RTX-M1 series covers low-voltage feeder and incomer protection with one family: a compact 63A frame for small branch circuits up to an 800A frame for main incomers. Breaking capacity changes with frame and rating, so select from the model table rather than by current alone. The product label shows Ui 800V, Uimp 12kV and reference to GB/T 14048.2 and IEC 60947-2; the supplier holds CCC certification for the series.
Fitur Utama
- Six frames from 63A to 800A in one series
- 3P and 4P versions
- Icu 18kA to 50kA depending on frame and rating
- Label marking Ui 800V and Uimp 12kV; CCC certified series
Model / Konfigurasi yang Tersedia
Use these RITOKS configuration references for enquiry; confirm the exact specification before ordering.
| Referensi RITOKS | Tiang | Bingkai | Arus pengenal | Tegangan pengenal | Kapasitas puncak |
|---|---|---|---|---|---|
| RTX-M1-63/3P-16 | 3P | 63A | 16A | AC380V | 18kA |
| RTX-M1-63/3P-20 | 3P | 63A | 20A | AC380V | 18kA |
| RTX-M1-63/3P-25 | 3P | 63A | 25A | AC380V | 18kA |
| RTX-M1-63/3P-32 | 3P | 63A | 32A | AC380V | 32kA |
| RTX-M1-63/3P-40 | 3P | 63A | 40A | AC380V | 32kA |
| RTX-M1-63/3P-50 | 3P | 63A | 50A | AC380V | 32kA |
| RTX-M1-63/3P-63 | 3P | 63A | 63A | AC380V | 32kA |
| RTX-M1-100/3P-80 | 3P | 100A | 80A | AC380V | 50kA |
| RTX-M1-100/3P-100 | 3P | 100A | 100A | AC380V | 50kA |
| RTX-M1-225/3P-125 | 3P | 225A | 125A | AC380V | 50kA |
| RTX-M1-225/3P-140 | 3P | 225A | 140A | AC380V | 50kA |
| RTX-M1-225/3P-160 | 3P | 225A | 160A | AC380V | 50kA |
| RTX-M1-225/3P-180 | 3P | 225A | 180A | AC380V | 50kA |
| RTX-M1-225/3P-200 | 3P | 225A | 200A | AC380V | 50kA |
| RTX-M1-225/3P-225 | 3P | 225A | 225A | AC380V | 50kA |
| RTX-M1-400/3P-250 | 3P | 400A | 250 A | AC380V | 35 kA |
| RTX-M1-400/3P-315 | 3P | 400A | 315A | AC380V | 35 kA |
| RTX-M1-400/3P-350 | 3P | 400A | 350A | AC380V | 42kA |
| RTX-M1-400/3P-400 | 3P | 400A | 400A | AC380V | 42kA |
| RTX-M1-630/3P-500 | 3P | 630A | 500A | AC380V | 35 kA |
| RTX-M1-630/3P-630 | 3P | 630A | 630A | AC380V | 42kA |
| RTX-M1-800/3P-700 | 3P | 800A | 700A | AC380V | 35 kA |
| RTX-M1-800/3P-800 | 3P | 800A | 800A | AC380V | 35 kA |
| RTX-M1-63/4P | 4P | 63A | 16A–63A | AC380V | 42kA |
| RTX-M1-100/4P | 4P | 100A | 63A–100A | AC380V | 50kA |
| RTX-M1-225/4P | 4P | 225A | 100A–225A | AC380V | 50kA |
| RTX-M1-400/4P | 4P | 400A | 225A–400A | AC380V | 50kA |
| RTX-M1-630/4P | 4P | 630A | 400A–630A | AC380V | 50kA |
| RTX-M1-800/4P | 4P | 800A | 630A–800A | AC380V | 50kA |
Spesifikasi Teknis
| Jenis produk | AC molded case circuit breaker |
|---|---|
| Tiang | 3P, 4P |
| Frame currents | 63A, 100A, 225A, 400A, 630A, 800A |
| Arus pengenal | 16A–800A |
| Tegangan operasional terukur | AC380V |
| Rated insulation voltage Ui | 800V (product label) |
| Rated impulse voltage Uimp | 12kV (product label) |
| Kapasitas puncak | 18kA, 32kA, 35kA, 42kA or 50kA by rating; see model table |
| Standards marked | GB/T 14048.2, IEC 60947-2 (product label) |
| Sertifikasi | CCC (supplier-listed) |
| Trip settings and accessories | Confirm with RITOKS before ordering |
Aplikasi
AI-generated conceptual application context. Confirm equipment fit, installation conditions and circuit requirements for the selected configuration.

Main LV switchboards
Use the 400A–800A frames as incomers or main feeders in low-voltage distribution boards.
Sub-distribution feeders
Protect outgoing feeders to floors, production lines or MCC sections with 100A–225A frames.
Equipment supply circuits
Apply 63A frame ratings to compressors, chillers and machine supplies that need more breaking capacity than an MCB.
Informasi yang Perlu Dipastikan untuk Proses Seleksi
- Rated current and frame size
- Prospective short-circuit current at the installation point
- Number of poles and neutral arrangement
- Terminal type, cable or busbar size, and accessories such as shunt trips or auxiliary contacts
Pertanyaan yang Sering Diajukan
Why do breaking capacities differ within one frame?
The supplier rates some current settings differently, for example 18kA for 16A–25A and 32kA for 32A–63A on the 63A frame. Use the exact row in the model table.
Are the trip units adjustable?
Adjustment data is not published for this series. Confirm trip type and settings with RITOKS before ordering.
Minta Penawaran Harga