{"id":1909,"date":"2026-10-01T00:18:51","date_gmt":"2026-10-01T00:18:51","guid":{"rendered":"https:\/\/ritoks.com\/?p=1909"},"modified":"2026-10-06T01:09:08","modified_gmt":"2026-10-06T01:09:08","slug":"scr-module-heatsink-selection-thermal-evidence","status":"publish","type":"post","link":"https:\/\/ritoks.com\/id\/scr-module-heatsink-selection-thermal-evidence\/","title":{"rendered":"Pemilihan Modul SCR dan Heatsink: Diperlukan Bukti Termal"},"content":{"rendered":"<p class=\"wp-block-paragraph\">Nilai arus modul SCR tidak menentukan ukuran heatsink-nya. Keputusan termal bergantung pada kerugian daya dalam siklus operasi aktual, suhu sambungan yang diizinkan, jalur termal dari sambungan ke casing dan antarmuka, kondisi pendinginan, serta cara pemasangan modul. Penawaran harga untuk sebuah modul dan ekstrusi aluminium yang tampak besar bukanlah desain termal yang lengkap.<\/p>\n<p class=\"wp-block-paragraph\">Panduan ini menguraikan data yang perlu diminta sebelum memilih heatsink untuk modul thyristor. Panduan ini berfokus pada data masukan, batasan perhitungan, dan verifikasi, bukan pada penetapan nilai resistansi termal untuk rangkaian yang belum diketahui. Kode pemesanan SCR yang tepat dan bentuk gelombang aplikasi tetap menjadi hal yang sangat penting.<\/p>\n<h2 class=\"wp-block-heading\">Mulailah dengan bentuk gelombang aplikasi<\/h2>\n<p class=\"wp-block-paragraph\">Catat topologi rangkaian dan fungsi masing-masing thyristor: penyearah terkendali, pengendalian daya AC, soft starting, atau fungsi lainnya. Perhatikan apakah modul tersebut terdiri dari satu perangkat, konfigurasi ganda, atau koneksi internal lainnya. Nilai arus yang tertera pada pelat nama yang sama dapat mewakili durasi konduksi, bentuk pulsa, dan pembangkitan panas yang sangat berbeda-beda pada rangkaian yang berbeda.<\/p>\n<p class=\"wp-block-paragraph\">Provide the RMS and average current information relevant to the manufacturer&#8217;s loss model, together with conduction angle, repetition, duty cycle and overload events. Include the current waveform or a validated simulation when possible. Do not take a sine-wave datasheet test point and treat it as a universal loss figure for a chopped or highly pulsed application.<\/p>\n<p class=\"wp-block-paragraph\">Identifikasi secara terpisah beban berkelanjutan terburuk dan kondisi transien yang signifikan. Proses startup, arus masuk awal (inrush), dan kelebihan beban jangka pendek mungkin memerlukan tinjauan impedansi termal transien, sedangkan operasi berkelanjutan memerlukan analisis kondisi mapan. Massa termal heatsink tidak menjadi alasan untuk mengabaikan pulsa yang berulang; pengulangan tersebut dapat menghalangi sistem untuk kembali ke suhu awalnya.<\/p>\n<h2 class=\"wp-block-heading\">Menghitung kerugian berdasarkan informasi model yang tepat<\/h2>\n<p class=\"wp-block-paragraph\">Request the exact model&#8217;s on-state voltage or loss parameters and the manufacturer&#8217;s recommended calculation method. Where the module has multiple devices, track loss per conducting element and the total heat injected into the shared baseplate. Power loss is an input to thermal analysis; it is not the same as the output power or load rating of the equipment.<\/p>\n<p class=\"wp-block-paragraph\">Periksa apakah lembar data mencantumkan kurva pada suhu sambungan dan kondisi arus tertentu. Jika pemasok hanya memberikan satu nilai \u201ckhas\u201d, tanyakan kondisi yang dimaksud dan apakah tersedia nilai maksimum atau nilai desain. Catat tingkat ketidakpastian daripada menyajikan suhu sink yang tepat berdasarkan data khas yang belum diverifikasi.<\/p>\n<p class=\"wp-block-paragraph\">Untuk sistem penyearah atau sistem pengendalian fasa, jelaskan baik jalur konduksi maupun pembagian arus antar perangkat sepanjang waktu. Modul SCR ganda mungkin tidak membagi kerugian secara merata jika skema pengendalian atau operasi rangkaian bersifat asimetris. Model termal harus mencerminkan perangkat konduksi yang sebenarnya dan, jika diperlukan, kedekatan beberapa sumber panas pada satu pendingin.<\/p>\n<figure data-spectra-id=\"spectra-520f2286-c303-43c1-8589-cf034964c9a6\" class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" height=\"1050\" width=\"1400\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/scr-module-heatsink-selection-thermal-evidence-body-01.webp\" alt=\"Jalur resistansi termal SCR dari sambungan ke casing, antarmuka, heatsink, dan lingkungan sekitar\" class=\"wp-image-1907\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/scr-module-heatsink-selection-thermal-evidence-body-01.webp 1400w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/scr-module-heatsink-selection-thermal-evidence-body-01-300x225.webp 300w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/scr-module-heatsink-selection-thermal-evidence-body-01-1024x768.webp 1024w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/scr-module-heatsink-selection-thermal-evidence-body-01-768x576.webp 768w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/scr-module-heatsink-selection-thermal-evidence-body-01-600x450.webp 600w\" sizes=\"auto, (max-width: 1400px) 100vw, 1400px\" \/><figcaption class=\"wp-element-caption\">Lacak panas SCR dari sambungan melalui antarmuka hingga ke udara sekitar.<\/figcaption><\/figure>\n<h2 class=\"wp-block-heading\">Baca jalur termal selengkapnya<\/h2>\n<p class=\"wp-block-paragraph\">A simplified steady-state path runs from junction to case, case through thermal interface material to heatsink, and heatsink to ambient. Each stage contributes temperature rise under the relevant heat flow. Infineon&#8217;s module mounting guidance emphasizes that thermal interface material, application and geometry affect conduction between module and sink. No catalogue heatsink number can compensate for a poorly controlled contact interface.<\/p>\n<p class=\"wp-block-paragraph\">Obtain the exact module&#8217;s thermal-resistance or transient-impedance data and understand the measurement reference points. \u201cJunction-to-case\u201d is not automatically comparable across different internal configurations or test conventions. The sink supplier&#8217;s thermal-resistance figure also has conditions: airflow, orientation, base area and a particular heat-source arrangement may be assumed.<\/p>\n<p class=\"wp-block-paragraph\">Check where the equipment&#8217;s ambient reference is measured. Air near an SCR bank, inside a crowded cabinet, may be hotter than room air. A fan&#8217;s free-air rating is not the airflow through the sink fins once filters, guards and nearby components are installed. In a design review, use the relevant local inlet-air condition rather than the most favorable laboratory ambient.<\/p>\n<h2 class=\"wp-block-heading\">Sertakan deskripsi antarmuka dan prosedur pemasangan<\/h2>\n<p class=\"wp-block-paragraph\">Thermal compound, pad or factory-applied interface material is part of the designed path. Record which interface is allowed for the exact module, the required surface flatness and cleanliness, and the manufacturer&#8217;s placement and fastening sequence. A change of compound or mounting pressure can change contact resistance even if the electrical module and sink are unchanged.<\/p>\n<p class=\"wp-block-paragraph\">Ask for specified mounting torque, fastener pattern, electrical clearances and any re-tightening or burn-in instruction. These details should come from the current module installation manual, not from a generic torque chart. Infineon&#8217;s power-module documentation explicitly treats mounting as a thermal-performance and reliability issue; RITOKS products require their own exact-model instructions before assembly release.<\/p>\n<p class=\"wp-block-paragraph\">Pertimbangkan apakah beberapa modul berbagi satu heatsink. Gangguan mekanis, penyebaran panas, isolasi listrik, dan hambatan aliran udara dapat memengaruhi kinerja. Jika heatsink tersebut terhubung secara listrik ke bagian sirkuit melalui dasar modul, desainnya harus memperhatikan persyaratan isolasi dan jarak aman yang diperlukan, alih-alih memperlakukan heatsink tersebut sebagai komponen logam yang tidak berbahaya.<\/p>\n<h2 class=\"wp-block-heading\">Bandingkan konveksi alami dan konveksi paksa pada geometri yang dipasang<\/h2>\n<p class=\"wp-block-paragraph\">Konveksi alami sangat bergantung pada orientasi sirip, jarak antar sirip, dan aliran udara naik yang tidak terhalang. Konveksi paksa bergantung pada aliran udara yang disalurkan melalui penukar panas, bukan hanya aliran udara bebas yang dihasilkan kipas. Pilihan ini juga memengaruhi persyaratan akustik, debu, filter, dan pemeliharaan. Pastikan apakah kabinet dapat menopang aliran udara yang direncanakan selama masa pakainya.<\/p>\n<p class=\"wp-block-paragraph\">Request a sink performance curve or tested thermal resistance under conditions close to the installed arrangement. If the data uses another heat-source footprint, ask the sink supplier how to correct or test it. Infineon&#8217;s heatsink-selection guidance stresses that optimization is iterative and that published thermal resistance is conditional on how it was measured.<\/p>\n<p class=\"wp-block-paragraph\">Margin pendinginan harus didasarkan pada ketidakpastian yang dihitung, kondisi lingkungan ekstrem, dan asumsi pemeliharaan. Memilih ukuran radiator yang terlalu besar tanpa memeriksa antarmuka dan aliran udara dapat menyebabkan titik leher botol yang sebenarnya terlewatkan. Sebaliknya, radiator berukuran kecil mungkin dapat diandalkan untuk operasi intermiten hanya jika model panas transien dan frekuensi pengulangan telah didokumentasikan.<\/p>\n<h2 class=\"wp-block-heading\">Gunakan tabel bukti termal, bukan perbandingan yang hanya berdasarkan arus<\/h2>\n<figure class=\"wp-block-table\"><table><thead><tr><th>Barang bukti<\/th><th>Perlengkapan proyek<\/th><th>Pemasok mengonfirmasi<\/th><\/tr><\/thead><tbody><tr><td>Tugas kelistrikan<\/td><td>Bentuk gelombang, pola konduksi, kelebihan beban<\/td><td>Metode penentuan kehilangan perangkat secara tepat<\/td><\/tr><tr><td>Batas persimpangan<\/td><td>Ruang lingkup operasi desain<\/td><td>Batas suhu model eksak<\/td><\/tr><tr><td>Jalur termal internal<\/td><td>Penempatan perangkat di wastafel<\/td><td>Data sambungan ke casing<\/td><\/tr><tr><td>Antarmuka<\/td><td>Proses perakitan<\/td><td>TIM yang diizinkan dan petunjuk pemasangan<\/td><\/tr><tr><td>Jalur dari laut ke udara<\/td><td>Pengaturan suhu ruangan dan aliran udara<\/td><td>Kinerja wastafel pada kondisi yang relevan<\/td><\/tr><\/tbody><\/table><\/figure>\n<p class=\"wp-block-paragraph\">Pastikan semua data masukan terkait dengan revisi gambar dan kode pesanan. Perubahan pada topologi SCR, kemasan modul, jalur aliran udara, atau bentuk gelombang kendali dapat membuat perhitungan panas awal menjadi tidak valid. Bagian pengadaan tidak boleh mengganti modul dengan yang \u201csetara\u201d hanya berdasarkan label arus dan tegangan jika jalur termalnya berbeda.<\/p>\n<figure data-spectra-id=\"spectra-58baa3e2-b637-4447-a93f-e72cbd2a5944\" class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" height=\"1050\" width=\"1400\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/scr-module-heatsink-selection-thermal-evidence-body-02.webp\" alt=\"Daftar periksa bukti heatsink SCR yang mencocokkan beban listrik dengan dokumen modul, antarmuka, dan heatsink\" class=\"wp-image-1908\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/scr-module-heatsink-selection-thermal-evidence-body-02.webp 1400w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/scr-module-heatsink-selection-thermal-evidence-body-02-300x225.webp 300w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/scr-module-heatsink-selection-thermal-evidence-body-02-1024x768.webp 1024w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/scr-module-heatsink-selection-thermal-evidence-body-02-768x576.webp 768w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/scr-module-heatsink-selection-thermal-evidence-body-02-600x450.webp 600w\" sizes=\"auto, (max-width: 1400px) 100vw, 1400px\" \/><figcaption class=\"wp-element-caption\">Catat dokumen-dokumen yang diperlukan untuk menyelesaikan setiap asumsi desain termal.<\/figcaption><\/figure>\n<h2 class=\"wp-block-heading\">Lakukan validasi dengan pengukuran pada beban yang representatif<\/h2>\n<p class=\"wp-block-paragraph\">Calculation screens candidates; installed testing verifies the model. Define the operating cycle, enclosure condition and measurement points before the test. A case or sink temperature reading is meaningful only when its location matches the calculation reference. If direct junction measurement is unavailable, use the manufacturer&#8217;s approved method to infer junction temperature from measured values and losses.<\/p>\n<p class=\"wp-block-paragraph\">Periksa kondisi beban tinggi yang berkelanjutan serta kondisi transien atau siklus berulang yang penting. Dokumentasikan kecepatan kipas, kondisi filter, suhu lingkungan, dan sumber panas di sekitarnya. Jika suhu yang diukur berbeda dari prediksi, teliti asumsi kerugian, penerapan antarmuka, aliran udara, dan posisi sensor. Hindari menyembunyikan ketidaksesuaian dengan menyesuaikan satu nilai resistansi yang diasumsikan tanpa bukti.<\/p>\n<p class=\"wp-block-paragraph\">Sertakan pengendalian perakitan produksi. Sebuah prototipe yang dirakit dengan cermat oleh seorang insinyur mungkin menunjukkan kinerja yang berbeda dari rakitan serupa jika cakupan bahan atau urutan pemasangan baut berbeda. Tentukan titik-titik pemeriksaan yang praktis diterapkan di lantai produksi, kemudian simpan proses perakitan yang telah diverifikasi bersama dengan catatan produk.<\/p>\n<h2 class=\"wp-block-heading\">Apa saja yang perlu dilampirkan dalam permintaan informasi mengenai modul SCR<\/h2>\n<p class=\"wp-block-paragraph\">Kirimkan topologi rangkaian, bentuk gelombang dan siklus kerja, tegangan blokir yang diperlukan, kemungkinan kejadian kelebihan beban, ruang yang tersedia untuk heatsink, kondisi lingkungan dan aliran udara, tata letak pemasangan, serta dokumentasi yang diperlukan. Mintalah data kerugian dan data termal modul yang tepat, gambar mekanis, panduan antarmuka, dan petunjuk pemasangan. Hal ini <a href=\"https:\/\/ritoks.com\/id\/product-category\/power-semiconductor-modules\/scr-thyristor-modules\/\">Kategori modul SCR\/tiristor<\/a> membantu mengidentifikasi kelompok produk; pemilihan tetap bergantung pada model masing-masing.<\/p>\n<p class=\"wp-block-paragraph\">Untuk memahami konteksnya, silakan tinjau <a href=\"https:\/\/ritoks.com\/id\/products\/mta-dual-scr-thyristor-module-25a-1000a\/\">Keluarga MTA dual-SCR<\/a>, <a href=\"https:\/\/ritoks.com\/id\/products\/mtc-scr-thyristor-module-55a-200a\/\">Keluarga MTC SCR<\/a> atau <a href=\"https:\/\/ritoks.com\/id\/products\/mtc-high-current-scr-module-250a-1500a\/\">Rangkaian MTC arus tinggi<\/a> sesuai kebutuhan. Halaman-halaman tersebut tidak dimaksudkan sebagai pengganti kurva kerugian terkini atau panduan pemasangan. Silakan tanyakan <a href=\"https:\/\/ritoks.com\/id\/contact-us\/\">RITOKS<\/a> untuk kumpulan dokumen tertentu sebelum membekukan kode pesanan.<\/p>\n<h2 class=\"wp-block-heading\">Pertanyaan yang Sering Diajukan<\/h2>\n<h3 class=\"wp-block-heading\">Apakah heatsink dapat dipilih berdasarkan nilai arus SCR?<\/h3>\n<p class=\"wp-block-paragraph\">Tidak. Nilai arus hanya merupakan salah satu parameter perangkat. Bentuk gelombang aktual, kerugian, kondisi lingkungan, antarmuka, dan pengaturan pendinginanlah yang menentukan persyaratan termal.<\/p>\n<h3 class=\"wp-block-heading\">Apakah menambahkan kipas angin menjamin margin yang lebih besar?<\/h3>\n<p class=\"wp-block-paragraph\">Hanya jika aliran udara yang memadai mencapai permukaan sirip yang bersangkutan dalam kondisi pemasangan. Periksa filter, adanya halangan, kondisi pengoperasian kipas, dan data kinerja pendingin.<\/p>\n<h3 class=\"wp-block-heading\">Apa yang dimaksud dengan bukti penerimaan akhir?<\/h3>\n<p class=\"wp-block-paragraph\">Perhitungan khusus model, metode pemasangan yang terkendali, dan uji suhu yang representatif secara bersama-sama menjadi dasar pengambilan keputusan yang dapat dipertanggungjawabkan. Tidak ada satu dokumen pun yang dapat membuktikan ketiga hal tersebut.<\/p>\n<h2 class=\"wp-block-heading\">Intinya<\/h2>\n<p class=\"wp-block-paragraph\">Tentukan terlebih dahulu kerugian listrik, kemudian telusuri jalur termal secara menyeluruh dan verifikasi rakitan yang telah dipasang. Pasangan modul SCR dan heatsink merupakan keputusan sistem. Biarkan data termal yang spesifik untuk model dan belum terselesaikan tetap tercantum dalam RFQ, daripada mengisinya dengan asumsi dari katalog. Gambar akhir harus mengidentifikasi modul, heatsink, bahan antarmuka, arah aliran udara, dan kondisi pengujian yang telah divalidasi sebagai satu rakitan yang terkendali.<\/p>\n<h2 class=\"wp-block-heading\">Daftar Pustaka<\/h2>\n<ul class=\"wp-block-list\"><li><a href=\"https:\/\/www.infineon.com\/dgdl\/Infineon-Use_and_Installation_Manual_34mm_and_50mm_Solder_Bond_Modules-ApplicationNotes-v01_03-EN.pdf?fileId=5546d462576f3475015775517f2622cd\" target=\"_blank\" rel=\"noopener\">Infineon, 34 mm and 50 mm Solder Bond Modules \u2014 Use and Installation Manual (AN2018-07)<\/a>.<\/li><li><a href=\"https:\/\/www.infineon.com\/dgdl\/Infineon-CIPOS_Maxi_IPM_IM12BxxxC1_series-ApplicationNotes-v01_00-EN.pdf?fileId=8ac78c8c90530b3a01908868b8ec22fb\" target=\"_blank\" rel=\"noopener\">Infineon, panduan perancangan sistem termal dan pemilihan heatsink<\/a> (prinsip-prinsip umum pendingin panas; bukan spesifikasi RITOKS SCR).<\/li><li><a href=\"https:\/\/www.semikron-danfoss.com\/service-support\/application-support\/application-manual\" target=\"_blank\" rel=\"noopener\">Semikron Danfoss, Panduan Aplikasi Semikonduktor Daya<\/a>.<\/li><\/ul>","protected":false},"excerpt":{"rendered":"<p>Select an SCR heatsink from application losses, complete thermal path, installed airflow and model-specific mounting evidence, not current rating alone.<\/p>","protected":false},"author":1,"featured_media":1906,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ritoks_resource_detail_renderer":"viox","ritoks_resource_product_cat_term_id":102,"footnotes":""},"categories":[66],"tags":[],"class_list":["post-1909","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-power-semiconductors"],"acf":[],"spectra_blocks_featured_image_url":{"thumbnail":{"url":"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/scr-module-heatsink-selection-thermal-evidence-hero-01-150x150.webp","width":150,"height":150},"medium":{"url":"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/scr-module-heatsink-selection-thermal-evidence-hero-01-300x169.webp","width":300,"height":169},"medium_large":{"url":"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/scr-module-heatsink-selection-thermal-evidence-hero-01-768x432.webp","width":768,"height":432},"large":{"url":"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/scr-module-heatsink-selection-thermal-evidence-hero-01-1024x576.webp","width":1024,"height":576},"full":{"url":"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/scr-module-heatsink-selection-thermal-evidence-hero-01.webp","width":1600,"height":900}},"spectra_blocks_author_info":{"display_name":"RITOKS","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/6d7d0fc73468198f994ab13ef6eb6558c53b6ed1ad86364d5165efe8bdf8eb4a?s=96&d=mm&r=g","author_link":"https:\/\/ritoks.com\/id\/author\/dazzlingwqbgmail-com\/","description":""},"_links":{"self":[{"href":"https:\/\/ritoks.com\/id\/wp-json\/wp\/v2\/posts\/1909","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ritoks.com\/id\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ritoks.com\/id\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ritoks.com\/id\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/ritoks.com\/id\/wp-json\/wp\/v2\/comments?post=1909"}],"version-history":[{"count":3,"href":"https:\/\/ritoks.com\/id\/wp-json\/wp\/v2\/posts\/1909\/revisions"}],"predecessor-version":[{"id":2228,"href":"https:\/\/ritoks.com\/id\/wp-json\/wp\/v2\/posts\/1909\/revisions\/2228"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ritoks.com\/id\/wp-json\/wp\/v2\/media\/1906"}],"wp:attachment":[{"href":"https:\/\/ritoks.com\/id\/wp-json\/wp\/v2\/media?parent=1909"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ritoks.com\/id\/wp-json\/wp\/v2\/categories?post=1909"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ritoks.com\/id\/wp-json\/wp\/v2\/tags?post=1909"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}