Electrical Measurement & Monitoring · RTX-ACT
RTX-ACT Through-Hole AC Current Transducers 4-20mA
DIN-rail AC current transducers with a through-hole sensing window and a 4–20mA output, in classic and high-accuracy versions from 0–5A to 0–200A.
InputAC 0–5A to 0–200A
Risultato4–20mA
MontaggioGuida DIN
Peso0.15 kg
Panoramica del prodotto
RTX-ACT transducers convert AC current passed through the window into a 4–20mA signal for PLCs and meters. The classic line covers 0–5A to 0–200A; the high-accuracy line covers 0–5A to 0–100A, with 5A and 10A versions wired to terminals. Supply voltage and accuracy must be confirmed by version.
Caratteristiche principali
- Through-hole window for primary conductor
- 4–20mA analog output
- Classic and high-accuracy lines
- Montaggio su guida DIN
Modelli / Configurazioni disponibili
Use these RITOKS configuration references for enquiry; confirm the exact specification before ordering.
| Riferimento RITOKS | Line | Input | Connessione |
|---|---|---|---|
| RTX-ACT5 | Classic | AC 0–5A | Through-hole |
| RTX-ACT10 | Classic | AC 0–10A | Through-hole |
| RTX-ACT20 | Classic | AC 0–20A | Through-hole |
| RTX-ACT30 | Classic | AC 0–30A | Through-hole |
| RTX-ACT50 | Classic | AC 0–50A | Through-hole |
| RTX-ACT100 | Classic | AC 0–100A | Through-hole |
| RTX-ACT200 | Classic | AC 0–200A | Through-hole |
| RTX-ACT-H5 | High accuracy | AC 0–5A | Terminal wired |
| RTX-ACT-H10 | High accuracy | AC 0–10A | Terminal wired |
| RTX-ACT-H20 | High accuracy | AC 0–20A | Through-hole |
| RTX-ACT-H30 | High accuracy | AC 0–30A | Through-hole |
| RTX-ACT-H50 | High accuracy | AC 0–50A | Through-hole |
| RTX-ACT-H100 | High accuracy | AC 0–100A | Through-hole |
Specifiche tecniche
| Tipo di prodotto | Trasduttore di corrente alternata |
|---|---|
| Input | AC 0–5A to 0–200A by model |
| Risultato | 4–20mA |
| Montaggio | Guida DIN |
| Peso | 0.15 kg |
| Supply and accuracy | Not published per model; confirm with ritoks before ordering |
Applicazioni
AI-generated conceptual application context. Confirm equipment fit, installation conditions and circuit requirements for the selected configuration.

PLC energy monitoring
Feed motor or feeder current to PLC analog inputs.
Pump and fan supervision
Detect running, overload and dry-run states from current.
Panel meters
Drive 4–20mA indicators for branch circuit current.
Informazioni da verificare ai fini della selezione
- Input range and conductor size
- Classic or high-accuracy line
- Auxiliary supply voltage
- Required accuracy and quantity
Domande frequenti
What supply voltage does it need?
Supply is not published per model. Confirm it before ordering.
Which models are wired instead of through-hole?
The high-accuracy 5A and 10A models connect by terminals; others use the through-hole window.
Richiedi un preventivo