지금 문의하기
RITOKS RTX-RTT311 DIN rail temperature transmitter

Electrical Measurement & Monitoring · RTX-RTT311

RTX-RTT311 DIN-Rail Temperature Transmitters

A single-input, single-output DIN-rail transmitter for RTD or thermocouple signals. The RTX-RTT311 reference covers the self-powered 4–20 mA configuration; Pt1000 is a custom option and must be confirmed.

입력Pt100 / Cu50 / Cu100 RTD; thermocouple options

출력4–20 mA self-powered; other codes by configuration

정확도RTD: ±0.1 °C below 100 °C or ±0.1% FS above

공급18–32 VDC for self-powered version

제품 개요

A single-input, single-output DIN-rail transmitter for RTD or thermocouple signals. The RTX-RTT311 reference covers the self-powered 4–20 mA configuration; Pt1000 is a custom option and must be confirmed.

주요 기능

  • PC-configurable input type and range
  • Supports 2, 3 and 4-wire RTD connections
  • Input, output and supply isolation
  • DIN rail installation with PWR and ALM indication

사용 가능한 모델 / 구성

Use these RITOKS configuration references for enquiry; confirm the exact specification before ordering.

RTX-RTT3111 input / 1 output / 4–20 mA self-powered
RTX-RTT311-V1 input / 1 output / 0–10 V
RTX-RTT311-LP1 input / 1 output / 4–20 mA loop-powered

기술 사양

입력Pt100 / Cu50 / Cu100 RTD; thermocouple options
출력4–20 mA self-powered; other codes by configuration
정확도RTD: ±0.1 °C below 100 °C or ±0.1% FS above
공급18–32 VDC for self-powered version
고립Input, output and supply galvanically isolated
Response≤0.5 s
장착35 mm standard DIN rail
치수12.7 × 110 × 118.9 mm (T × H × D)

응용 분야

AI-generated conceptual application context. Confirm equipment fit, installation conditions and circuit requirements for the selected configuration.

AI-generated conceptual application scene: DIN-rail temperature transmitter connected to RTD sensors in a process control cabinet

제어반

Convert RTD signals to a compatible analog control input.

Process skids

Use programmable ranges for verified temperature sensors.

Heating equipment

Confirm sensor wiring, range and output loop before commissioning.

선정을 위해 확인해야 할 사항

  • Sensor type and 2/3/4-wire connection
  • Temperature range and output code
  • Self-powered or loop-powered architecture
  • Break detection, load and ambient conditions

자주 묻는 질문

What information is needed for a quotation?

Please include the exact configuration reference, quantity, destination and documentation requirements.

견적 요청하기

정확한 모델명, 필요한 정격, 수량 및 배송지를 알려주십시오. 견적서를 발행하기 전에 재고 현황과 필요한 서류를 확인해 드리겠습니다.

제품 정보 및 가격 문의하기

모델 번호, 정격 사양, 수량 및 배송지 정보를 보내 주십시오. 견적을 작성하기 전에 재고 여부를 확인해 드리겠습니다.

맨 위로 스크롤하기