{"id":2485,"date":"2026-10-13T01:27:22","date_gmt":"2026-10-13T01:27:22","guid":{"rendered":"http:\/\/ritoks.com\/"},"modified":"2026-10-13T01:27:22","modified_gmt":"2026-10-13T01:27:22","slug":"battery-combine-function-bank-compatibility","status":"publish","type":"post","link":"https:\/\/ritoks.com\/ko\/battery-combine-function-bank-compatibility\/","title":{"rendered":"Battery Combine Functions: Check Bank Compatibility Before Use"},"content":{"rendered":"<h2 class=\"wp-block-heading\">Quick answer<\/h2>\n<p class=\"wp-block-paragraph\">A battery switch&#8217;s combine position describes a connection function, not approval to parallel any two banks. Confirm the exact switch circuit, both battery manufacturers&#8217; requirements, permitted voltage and charge conditions, charging equipment and protection design. Agree when combining is allowed and how normal operation is restored before releasing the assembly for use.<\/p>\n<p class=\"wp-block-paragraph\">The buyer&#8217;s task is to obtain that decision from the responsible electrical designer, with traceable documents. This guide is a procurement review, not a switching instruction for a live battery system. It supplies no universal voltage-difference threshold, state-of-charge limit or emergency starting procedure. An apparently weak battery is not enough information to approve combining it with another source.<\/p>\n<h2 class=\"wp-block-heading\">Confirm what the selected switch actually combines<\/h2>\n<p class=\"wp-block-paragraph\">Start with the exact model and a circuit-state drawing. A selector, a dual-circuit switch and an ON\/OFF disconnect can look similar while creating different connections. Ask which battery feeds which load in every labelled position, and which terminals become common in the combine state. A photograph of the knob does not settle the contact arrangement.<\/p>\n<p class=\"wp-block-paragraph\">\uadf8 <a href=\"https:\/\/ritoks.com\/ko\/products\/sfcbs-300-battery-disconnect-switches\/\">RITOKS SFCBS-300 family<\/a> documents combine capability for SFCBS-300-402 and SFCBS-300-301, but not for SFCBS-300-202 or SFCBS-300-203. Select the required architecture first. Do not transfer a combine function to the other models because the family name or enclosure looks similar.<\/p>\n<p class=\"wp-block-paragraph\">For an external illustration of the distinction, Blue Sea Systems describes its 5511e Dual Circuit Plus switch as operating isolated banks or combining banks to the loads. Its product information also says that configuration cannot switch positive and negative conductors because of the combine feature. That limitation concerns the Blue Sea model; obtain the exact RITOKS terminal drawing rather than assuming identical wiring. <a href=\"https:\/\/www.bluesea.com\/products\/5511e\/e-Series_Dual_Circuit_Plus_Battery_Switch\" target=\"_blank\" rel=\"noopener\">Blue Sea 5511e product documentation<\/a><\/p>\n<p class=\"wp-block-paragraph\">Keep the proposed use separate from the hardware name. Temporary starting assistance, sharing loads and permanent parallel operation are different design requests. Define the intended state, who may select it and the condition for leaving it. A useful quotation identifies both the switch variant and the approved operating purpose.<\/p>\n<h2 class=\"wp-block-heading\">Build a bank compatibility record before selecting combine<\/h2>\n<p class=\"wp-block-paragraph\">A compatibility record should identify the actual batteries, not only their nominal system voltage. Include the manufacturer, exact model, chemistry and arrangement of each bank. Record whether the request joins complete banks or individual batteries, because the connection architecture determines which manufacturer instruction applies. Avoid treating a permission for one product family as a general battery rule.<\/p>\n<p class=\"wp-block-paragraph\">Victron&#8217;s Lithium Smart Battery manual has separate requirements for parallel, series and series\/parallel arrangements. Its discussion of different batteries distinguishes those configurations rather than applying one blanket answer about capacity or age. The manual also treats the battery management system and charger configuration as parts of installation. Those are requirements for the documented Victron system, not permission to combine arbitrary brands or chemistries. <a href=\"https:\/\/www.victronenergy.com\/media\/pg\/Lithium_Battery_Smart\/en\/installation.html\" target=\"_blank\" rel=\"noopener\">Victron Lithium Smart installation manual<\/a><\/p>\n<p class=\"wp-block-paragraph\">Use the following table as an original purchasing worksheet. It is not a manufacturer tolerance table or a test specification. The completed record should cite the applicable instruction and identify who resolved each question.<\/p>\n<figure class=\"wp-block-table\"><table>\n<thead>\n<tr>\n<th>\uac80\ud1a0 \ud56d\ubaa9<\/th>\n<th>Information to request<\/th>\n<th>Decision that information supports<\/th>\n<\/tr>\n<\/thead>\n<tbody><tr>\n<td>Bank identity<\/td>\n<td>Exact battery models, chemistry and bank arrangement<\/td>\n<td>Whether the proposed sources may be connected together<\/td>\n<\/tr>\n<tr>\n<td>Manufacturer permission<\/td>\n<td>Applicable parallel or combine guidance for both banks<\/td>\n<td>Whether the intended use is within documented conditions<\/td>\n<\/tr>\n<tr>\n<td>Operating condition<\/td>\n<td>Approved method to assess bank condition before combining<\/td>\n<td>Whether the present condition meets the agreed operating rule<\/td>\n<\/tr>\n<tr>\n<td>Voltage assessment<\/td>\n<td>Measurement conditions and manufacturer or designer limits<\/td>\n<td>Whether connection may proceed in the stated condition<\/td>\n<\/tr>\n<tr>\n<td>State of charge<\/td>\n<td>Required assessment method and its interpretation<\/td>\n<td>Whether available charge information is sufficient for the decision<\/td>\n<\/tr>\n<tr>\n<td>Protective controls<\/td>\n<td>BMS arrangement, disconnect actions and protection review<\/td>\n<td>Whether a shared connection defeats a required control<\/td>\n<\/tr>\n<tr>\n<td>Charge sources<\/td>\n<td>Chargers, alternator interfaces and approved operating modes<\/td>\n<td>Whether charging remains suitable when banks are connected<\/td>\n<\/tr>\n<\/tbody><\/table><\/figure>\n<p class=\"wp-block-paragraph\">The worksheet should allow an unresolved outcome. If a manufacturer has not approved the proposed combination, write that fact explicitly and keep combine operation outside the released operating instruction. A complete-looking form with guesses in the acceptance column is less useful than a short record with a named open issue.<\/p>\n<figure data-spectra-id=\"spectra-7601071e-22a5-4226-8a2e-4d62054c6c34\" class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1536\" height=\"1024\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/battery-combine-function-bank-compatibility-body-01.webp\" alt=\"Source identity, source permission, present-condition assessment and charging compatibility answer different bank-combination questions.\" class=\"wp-image-2483\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/battery-combine-function-bank-compatibility-body-01.webp 1536w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/battery-combine-function-bank-compatibility-body-01-300x200.webp 300w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/battery-combine-function-bank-compatibility-body-01-1024x683.webp 1024w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/battery-combine-function-bank-compatibility-body-01-768x512.webp 768w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/battery-combine-function-bank-compatibility-body-01-18x12.webp 18w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/battery-combine-function-bank-compatibility-body-01-600x400.webp 600w\" sizes=\"auto, (max-width: 1536px) 100vw, 1536px\" \/><figcaption class=\"wp-element-caption\">Evidence categories, not a bank approval, universal voltage threshold or instruction to combine sources.<\/figcaption><\/figure>\n<h2 class=\"wp-block-heading\">Do not turn matching voltage into a complete approval<\/h2>\n<p class=\"wp-block-paragraph\">Nominal voltage is an identifying field, not a measured condition. Ask the designer how actual voltage and state of charge must be assessed for the installed battery systems. Specify the measurement location, relevant load or charge state and the source of the acceptance criterion. Do not copy a convenient threshold from a different battery installation.<\/p>\n<p class=\"wp-block-paragraph\">A difference in bank voltage belongs in the connection review because a newly joined path can carry current between the sources, as well as current demanded by the loads. The responsible designer should evaluate that path using the actual batteries and complete circuit. A blog cannot determine the transient from the nameplate voltage or claim that a particular knob position makes it harmless.<\/p>\n<p class=\"wp-block-paragraph\">State-of-charge information also needs context. Ask how it is obtained, whether the reading is current and whether it represents the bank being considered. Where the supplier cannot provide a valid assessment, do not replace it with an invented percentage limit. Document the approved way to establish readiness instead.<\/p>\n<p class=\"wp-block-paragraph\">For a battery-switch combine function, review two separate permissions: whether the sources may be joined at all, and whether the present operating condition meets the approved rule. Hardware suitability answers neither question by itself. Both decisions belong in the operating record, with their applicable conditions visible to the person responsible for use.<\/p>\n<h2 class=\"wp-block-heading\">Review charging equipment and BMS behavior in every state<\/h2>\n<p class=\"wp-block-paragraph\">Draw the charging connections alongside the switch states. Identify the equipment that can charge each bank during normal operation and the equipment still connected when combine is selected. Ask the charger and battery suppliers to confirm the proposed arrangement. A charging setting that is approved for one isolated bank should not be assumed suitable for every connected source.<\/p>\n<p class=\"wp-block-paragraph\">For systems with battery management controls, identify how charge and discharge permissions act on the actual connected equipment. The review should ask whether combining creates another source path after a control has disconnected its usual path. This is a question for the complete circuit and the applicable BMS instructions, not an assertion that every BMS behaves the same way.<\/p>\n<p class=\"wp-block-paragraph\">Also define what happens when an operating state changes. If an engine-driven charge source is involved, obtain its required switching restrictions and control arrangement from the relevant instructions. Do not claim the manual switch automatically manages an alternator, charger or battery protection system unless the selected model&#8217;s documentation establishes that function.<\/p>\n<p class=\"wp-block-paragraph\">The result should be a state record showing batteries, loads and charging equipment together. It must distinguish the normal mode, any permitted temporary combined mode and the return to normal. Record prohibited combinations as plainly as permitted ones so maintenance staff do not interpret silence as approval.<\/p>\n<h2 class=\"wp-block-heading\">Separate carrying current from switching and fault protection<\/h2>\n<p class=\"wp-block-paragraph\">Current ratings answer different questions. Continuous and timed current figures should remain tied to their specified conditions, while an operating or breaking duty needs its own evidence. The SFCBS-300 product page explicitly says its timed ratings are not breaking-current ratings and that breaking current is not specified in the available evidence. Do not convert a cranking figure into a load-breaking claim.<\/p>\n<p class=\"wp-block-paragraph\">The same product page identifies these devices as manual disconnect and selector switches rather than replacements for DC circuit breakers. Request the protection design independently, including the equipment protecting each source path and any shared path created by combining. The designer must evaluate actual circuit duties instead of accepting the switch as a universal fault-clearing device.<\/p>\n<figure class=\"wp-block-table\"><table>\n<thead>\n<tr>\n<th>Circuit state<\/th>\n<th>Questions for the controlled drawing<\/th>\n<th>Supporting record<\/th>\n<\/tr>\n<\/thead>\n<tbody><tr>\n<td>Normal isolated operation<\/td>\n<td>Which bank supplies each load and charge path?<\/td>\n<td>Exact terminal map and normal operating description<\/td>\n<\/tr>\n<tr>\n<td>Proposed combined operation<\/td>\n<td>Which source and load paths become common?<\/td>\n<td>Battery permission and complete circuit review<\/td>\n<\/tr>\n<tr>\n<td>Change into or out of combine<\/td>\n<td>What duties and restrictions apply during transition?<\/td>\n<td>Exact switch and connected-equipment instructions<\/td>\n<\/tr>\n<tr>\n<td>A bank or control unavailable<\/td>\n<td>Can another path feed the affected circuit?<\/td>\n<td>Protective-control response review<\/td>\n<\/tr>\n<tr>\n<td>Return to normal operation<\/td>\n<td>Who restores the state and confirms the condition?<\/td>\n<td>Released operating record and handover responsibility<\/td>\n<\/tr>\n<\/tbody><\/table><\/figure>\n<p class=\"wp-block-paragraph\">The table is a document-review aid, not a wiring diagram. In particular, it does not show terminal numbers or prescribe a conductor path. Obtain those details from the exact model documentation and the approved installation design, then retain the corresponding revision with the purchase record.<\/p>\n<figure data-spectra-id=\"spectra-f04e77be-b363-4a1b-a684-41a2326bb7eb\" class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1400\" height=\"1050\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/battery-combine-function-bank-compatibility-body-02.webp\" alt=\"Carrying-current band separated from switching-duty and fault-protection questions\" class=\"wp-image-2484\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/battery-combine-function-bank-compatibility-body-02.webp 1400w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/battery-combine-function-bank-compatibility-body-02-300x225.webp 300w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/battery-combine-function-bank-compatibility-body-02-1024x768.webp 1024w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/battery-combine-function-bank-compatibility-body-02-768x576.webp 768w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/battery-combine-function-bank-compatibility-body-02-16x12.webp 16w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/battery-combine-function-bank-compatibility-body-02-600x450.webp 600w\" sizes=\"auto, (max-width: 1400px) 100vw, 1400px\" \/><figcaption class=\"wp-element-caption\">Timed carrying-current data do not establish breaking-current capability or circuit protection.<\/figcaption><\/figure>\n<h2 class=\"wp-block-heading\">Use a simple voltage model without making a combine rule<\/h2>\n<p class=\"wp-block-paragraph\">Consider two fictional banks both described as nominally 12 V. For a teaching model only, represent them as fixed ideal voltage sources at 12.8 V and 12.2 V, joined through a total resistance of 0.02 \u03a9. There is no external load in this model. Ignore inductance, changing battery voltage and control actions solely to isolate the voltage-difference question. These assumptions are not a real battery equivalent circuit, SFCBS capability or instruction to connect banks.<\/p>\n<p class=\"wp-block-paragraph\">The assumed difference is 12.8 \u2212 12.2 = 0.6 V. In this deliberately resistive model, the algebraic source-to-source current is \u0394V\/R = 0.6\/0.02 = 30 A, directed from the higher modeled voltage toward the lower. That is not a measured or predicted switching peak, a permitted equalization current or a required switch rating. It shows only why two identical nominal-voltage labels do not imply zero current between newly common sources. The complete actual battery path may behave very differently.<\/p>\n<p class=\"wp-block-paragraph\">Change the lower modeled voltage to 12.7 V while retaining the other assumptions. The difference becomes 0.1 V and the model gives 0.1\/0.02 = 5 A. Changing only the assumed resistance from 0.02 \u03a9 to 0.01 \u03a9 in that second case instead gives 10 A. A sixfold smaller voltage difference produced a sixfold smaller current only because resistance and the rest of the ideal model stayed fixed. The voltage difference alone cannot establish the current, and an actual connection transient cannot be reconstructed from this calculation.<\/p>\n<p class=\"wp-block-paragraph\">None of 30 A, 5 A or 10 A is a combine acceptance threshold. A real review still needs the actual banks&#8217; permission, state assessment, charging arrangements and protective controls. It must identify the relevant dynamic circuit rather than treat an estimated resistance as a verified installation value. Lowering the modeled current does not authorize combining incompatible chemistries, defeated BMS control paths or a switch being used outside its documented duty. The example deliberately supplies no universal voltage-difference or state-of-charge limit.<\/p>\n<p class=\"wp-block-paragraph\">For a filled procurement finding, suppose the offered SFCBS-300-301 function matches the requested temporary combined state. The hardware-function row can reference that actual published variant, while bank identities, present-condition criteria and charging-mode permission remain unresolved. The ideal calculation belongs only in the explanation of why those missing conditions matter; it does not close them. If the requested switch were a variant without combine capability, resolving the bank questions would not manufacture the missing hardware function either.<\/p>\n<p class=\"wp-block-paragraph\">The final choice can change when the battery designer receives the relevant source and equipment evidence. One proposal may keep isolated normal operation and omit the requested temporary combine use; another may support that use under a defined operating record. Availability of a combine position is a convenience only within that documented scope. Keep component function, source compatibility and present operating permission separate, and retain the rule for returning to normal without inventing a live switching sequence.<\/p>\n<h2 class=\"wp-block-heading\">Conclusion<\/h2>\n<p class=\"wp-block-paragraph\">Approve a battery combine function through a linked record of the exact switch, the actual banks and the complete circuit states. Keep component ratings separate from operating permission and fault protection. The purchase is ready for the next decision when the responsible reviewer can explain what combining joins, when it is permitted and how the installation returns to its normal state.<\/p>\n<h2 class=\"wp-block-heading\">\ucc38\uace0 \ubb38\ud5cc<\/h2>\n<ol class=\"wp-block-list\">\n<li>RITOKS. (n.d.). <a href=\"https:\/\/ritoks.com\/ko\/products\/sfcbs-300-battery-disconnect-switches\/\">SFCBS-300 series battery disconnect switches<\/a>. Exact model functions and rating boundaries.<\/li>\n<li>Blue Sea Systems. (n.d.). <a href=\"https:\/\/www.bluesea.com\/products\/5511e\/e-Series_Dual_Circuit_Plus_Battery_Switch\" target=\"_blank\" rel=\"noopener\">5511e e-Series Dual Circuit Plus battery switch<\/a>. Manufacturer-specific operation and conductor-switching limitation.<\/li>\n<li>Victron Energy. (n.d.). <a href=\"https:\/\/www.victronenergy.com\/media\/pg\/Lithium_Battery_Smart\/en\/installation.html\" target=\"_blank\" rel=\"noopener\">Lithium Smart Battery manual: Installation<\/a>. Battery configuration, charging and BMS requirements within the documented product system.<\/li>\n<\/ol>","protected":false},"excerpt":{"rendered":"<p>Review exact switch states, battery permission, charging equipment and protection before approving a manual battery-bank combine function.<\/p>","protected":false},"author":1,"featured_media":2482,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ritoks_resource_detail_renderer":"viox","ritoks_resource_product_cat_term_id":116,"footnotes":""},"categories":[145],"tags":[],"class_list":["post-2485","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-power-switching-isolation"],"acf":[],"spectra_blocks_featured_image_url":{"thumbnail":{"url":"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/battery-combine-function-bank-compatibility-hero-01-150x150.webp","width":150,"height":150},"medium":{"url":"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/battery-combine-function-bank-compatibility-hero-01-300x169.webp","width":300,"height":169},"medium_large":{"url":"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/battery-combine-function-bank-compatibility-hero-01-768x432.webp","width":768,"height":432},"large":{"url":"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/battery-combine-function-bank-compatibility-hero-01-1024x576.webp","width":1024,"height":576},"full":{"url":"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/battery-combine-function-bank-compatibility-hero-01.webp","width":1600,"height":900}},"spectra_blocks_author_info":{"display_name":"RITOKS","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/6d7d0fc73468198f994ab13ef6eb6558c53b6ed1ad86364d5165efe8bdf8eb4a?s=96&d=mm&r=g","author_link":"https:\/\/ritoks.com\/ko\/author\/dazzlingwqbgmail-com\/","description":""},"_links":{"self":[{"href":"https:\/\/ritoks.com\/ko\/wp-json\/wp\/v2\/posts\/2485","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ritoks.com\/ko\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ritoks.com\/ko\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ritoks.com\/ko\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/ritoks.com\/ko\/wp-json\/wp\/v2\/comments?post=2485"}],"version-history":[{"count":1,"href":"https:\/\/ritoks.com\/ko\/wp-json\/wp\/v2\/posts\/2485\/revisions"}],"predecessor-version":[{"id":2486,"href":"https:\/\/ritoks.com\/ko\/wp-json\/wp\/v2\/posts\/2485\/revisions\/2486"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ritoks.com\/ko\/wp-json\/wp\/v2\/media\/2482"}],"wp:attachment":[{"href":"https:\/\/ritoks.com\/ko\/wp-json\/wp\/v2\/media?parent=2485"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ritoks.com\/ko\/wp-json\/wp\/v2\/categories?post=2485"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ritoks.com\/ko\/wp-json\/wp\/v2\/tags?post=2485"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}