Power Semiconductor Modules · RTX-SSR-H
RTX-SSR-H Single-Phase Solid-State Relays with Integrated Heatsink
DIN-rail solid-state relays with integrated heatsink for configured single-phase AC load control. The RTX-SSR-H reference maps to a 480 VAC, 40 A, 4–32 VDC zero-crossing configuration; confirm the exact variant and thermal requirements before order.
Laadspanning480 VAC
Belastingsstroom40 A
Besturingsingang4–32 VDC
SwitchingZero-crossing configuration
Productoverzicht
DIN-rail solid-state relays with integrated heatsink for configured single-phase AC load control. The RTX-SSR-H reference maps to a 480 VAC, 40 A, 4–32 VDC zero-crossing configuration; confirm the exact variant and thermal requirements before order.
Belangrijkste kenmerken
- Integrated heatsink for configured single-phase AC load switching
- 480 VAC load-voltage reference with 40 A current rating
- 4–32 VDC control input
- Zero-crossing configuration; variant confirmation required
Beschikbare modellen / configuraties
Use these RITOKS configuration references for enquiry; confirm the exact specification before ordering.
| RTX-SSR-H | 480 VAC / 40 A / 4–32 VDC / zero-crossing |
|---|---|
| RTX-SSR-H-Z | Zero-crossing variant; confirm thermal requirements |
| RTX-SSR-H-R | Random-turn-on variant by configuration |
Technische specificaties
| Laadspanning | 480 VAC |
|---|---|
| Belastingsstroom | 40 A |
| Besturingsingang | 4–32 VDC |
| Switching | Zero-crossing configuration |
| Warmtebeheer | Integrated heatsink; confirm derating and airflow for the selected load |
| Montage | DIN-rail or panel installation according to the selected housing |
| Type lading | Configured single-phase AC load control |
| Variant | Confirm zero-crossing or random-turn-on requirement before order |
Toepassingen
AI-generated conceptual application context. Confirm equipment fit, installation conditions and circuit requirements for the selected configuration.

Resistive heating loads
Switch configured single-phase heaters after current, thermal and duty-cycle review.
Panel-mounted AC loads
Use the integrated heatsink housing where enclosure airflow and derating are confirmed.
Industrial automation cabinets
Coordinate the 4–32 VDC control signal with the selected zero-crossing variant.
Te controleren gegevens voor de selectie
- Load voltage, load current and AC load type
- Control input and switching mode
- Heatsink airflow, mounting and derating conditions
- Required variant, quantity and destination
Veelgestelde vragen
Welke gegevens zijn nodig voor een offerte?
Please include the exact configuration reference, quantity, destination and documentation requirements.
Vraag een offerte aan
Geef het exacte model, de vereiste vermogens, het aantal stuks en de bestemming door. Wij zullen de beschikbaarheid en de benodigde documentatie controleren voordat we een offerte opstellen.