{"id":699,"date":"2026-09-05T16:51:06","date_gmt":"2026-09-05T16:51:06","guid":{"rendered":"https:\/\/ritoks.com\/?p=699"},"modified":"2026-09-20T06:54:43","modified_gmt":"2026-09-20T06:54:43","slug":"b-curve-vs-c-curve-vs-d-curve-mcb","status":"publish","type":"post","link":"https:\/\/ritoks.com\/nl\/b-curve-vs-c-curve-vs-d-curve-mcb\/","title":{"rendered":"MCB\u2019s met B-kromme, C-kromme en D-kromme: wat is het verschil?"},"content":{"rendered":"<div class=\"wp-block-group alignfull has-ast-global-color-5-color has-ast-global-color-2-background-color has-text-color has-background is-layout-constrained wp-container-core-group-is-layout-a2d0cf3a wp-block-group-is-layout-constrained\" style=\"padding-top:64px;padding-right:24px;padding-bottom:64px;padding-left:24px\">\n\n\n<h1 class=\"wp-block-heading\">MCB\u2019s met B-kromme, C-kromme en D-kromme: wat is het verschil?<\/h1>\n\n\n\n<figure data-spectra-id=\"spectra-7ae3ebe0-ab52-4b27-a27a-aae734750d50\" class=\"wp-block-image aligncenter size-full has-custom-border\" ><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-family-hero.png\" alt=\"Typische series AC-miniatuurstroomonderbrekers in een industri\u00eble elektrotechnische werkplaats\" class=\"wp-image-701\"  width=\"1672\" height=\"941\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-family-hero.png 1672w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-family-hero-600x338.png 600w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-family-hero-300x169.png 300w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-family-hero-1024x576.png 1024w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-family-hero-768x432.png 768w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-family-hero-1536x864.png 1536w\" sizes=\"auto, (max-width: 1672px) 100vw, 1672px\" \/><figcaption class=\"wp-element-caption\">Voorbeelden van gangbare AC-MCB-uitvoeringen in een industri\u00eble elektrische omgeving.<\/figcaption><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">De B-, C- en D-curves zijn verschillende uitschakelkarakteristieken die worden gebruikt bij <a href=\"https:\/\/ritoks.com\/nl\/product-category\/ac-power-protection\/miniature-circuit-breakers\/\">miniatuurstroomonderbrekers (MCB\u2019s)<\/a>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">De letters geven geen informatie over het huidige nominale vermogen, het uitschakelvermogen of het aantal polen. Ze geven daarentegen aan hoe de stroomonderbreker reageert op hogere kortstondige stromen binnen zijn onmiddellijke uitschakelbereik.<\/p>\n\n\n<\/div>\n\n\n\n<div class=\"wp-block-group alignfull is-layout-constrained wp-container-core-group-is-layout-105ba9aa wp-block-group-is-layout-constrained\" style=\"padding-top:64px;padding-right:24px;padding-bottom:64px;padding-left:24px\">\n\n\n<p class=\"wp-block-paragraph\">In de technische gegevens van de fabrikant worden doorgaans de volgende karakteristieke bereiken vermeld:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>B-curve: ongeveer 3\u20135 \u00d7 In<\/li>\n<li>C-kromme: ongeveer 5\u201310 \u00d7 In<\/li>\n<li>D-curve: ongeveer 10\u201320 \u00d7 In<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Hier staat \u2018In\u2019 voor de nominale stroom van de stroomonderbreker voor de betreffende karakteristiek. <a href=\"https:\/\/www.eaton.com\/content\/dam\/eaton\/support\/apac-support-assets\/japan-cps-assets\/products\/2023promotions_lp\/sccr2024_pdf01.pdf\" target=\"_blank\" rel=\"noopener\">Technische documentatie van Eaton<\/a> publiceert dezelfde B-, C- en D-kortsluitingsuitschakelbereiken voor zijn series miniatuurstroomonderbrekers.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Het praktische verschil is dat de drie krommen verschillende niveaus van kortstondige stroom kunnen verdragen voordat ze het gebied van onmiddellijke uitschakeling bereiken.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Dat betekent niet dat de ene curve per definitie beter is dan de andere.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">De vereiste curve moet worden afgeleid uit het daadwerkelijke elektrische ontwerp, de verwachte inschakelstroomomstandigheden en de documentatie van de gekozen stroomonderbreker.<\/p>\n\n\n\n<h2 id=\"in-this-guide\" class=\"wp-block-heading\">In deze handleiding<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"#quick-comparison\">Snelle vergelijking: B-curve versus C-curve versus D-curve<\/a><\/li>\n<li><a href=\"#mcb-trip-curve\">Wat is een uitschakelkarakteristiek van een MCB?<\/a><\/li>\n<li><a href=\"#b-curve\">Wat is een B-curve-stroomonderbreker?<\/a><\/li>\n<li><a href=\"#c-curve\">Wat is een MCB met C-kromme?<\/a><\/li>\n<li><a href=\"#d-curve\">Wat is een MCB met een D-curve?<\/a><\/li>\n<li><a href=\"#curve-availability\">Huidige beschikbaarheid van RITOKS-curves<\/a><\/li>\n<li><a href=\"#selection-process\">Hoe kies je tussen de opties met B-, C- en D-curve?<\/a><\/li>\n<li><a href=\"#frequently-asked-questions\">Veelgestelde vragen<\/a><\/li>\n<\/ul>\n\n\n\n<h2 id=\"quick-comparison\" class=\"wp-block-heading\">Snelle vergelijking: B-curve versus C-curve versus D-curve<\/h2>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table><thead><tr><th>Kenmerk<\/th><th>Gemeenschappelijk gebied voor onmiddellijke uitschakeling<\/th><th>Algemene context van de inschakelstroom<\/th><\/tr><\/thead><tbody><tr><td>B-curve<\/td><td>3\u20135 \u00d7 In<\/td><td>Lagere verwachte inschakelstroom<\/td><\/tr><tr><td>C-curve<\/td><td>5\u201310 \u00d7 In<\/td><td>Er wordt een matige inschakelstroom verwacht<\/td><\/tr><tr><td>D-curve<\/td><td>10\u201320 \u00d7 In<\/td><td>Hogere verwachte inschakelstroom<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Deze waarden geven de algemene kenmerken weer die door de belangrijkste MCB-fabrikanten zijn vastgelegd. Ze mogen niet worden beschouwd als een modelspecifieke RITOKS-tijd-stroomcurve, tenzij dit uitdrukkelijk wordt bevestigd in de productdocumentatie van RITOKS.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.eaton.com\/content\/dam\/eaton\/products\/electrical-circuit-protection\/industrial-miniature-circuit-breakers\/Industrial-breakers-catalog-ca08100005e.pdf\" target=\"_blank\" rel=\"noopener\">Eaton\u2019s richtlijnen voor industri\u00eble miniatuurstroomonderbrekers<\/a>, beschrijft bijvoorbeeld karakteristiek B voor situaties met een lagere inschakelstroom, C voor situaties met een gemiddelde inschakelstroom en D voor situaties met een hogere inschakelstroom. In de toepassingsrichtlijnen worden voorbeelden gegeven, zoals kleine transformatoren en besturingsapparatuur voor C-karakteristieken, en apparatuur met een hogere inschakelstroom, zoals motoren, transformatoren en voedingen, voor D-karakteristieken. Dit zijn typische voorbeelden, geen universele regels voor de keuze van de belasting.<\/p>\n\n\n\n<figure data-spectra-id=\"spectra-74197573-8c1c-4343-af18-141a57a54390\" class=\"wp-block-image aligncenter size-full has-custom-border\" ><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/b-c-d-curve-options-comparison.png\" alt=\"Conceptuele vergelijking van MCB-opties met B-, C- en D-curve\" class=\"wp-image-702\"  width=\"1672\" height=\"941\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/b-c-d-curve-options-comparison.png 1672w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/b-c-d-curve-options-comparison-600x338.png 600w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/b-c-d-curve-options-comparison-300x169.png 300w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/b-c-d-curve-options-comparison-1024x576.png 1024w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/b-c-d-curve-options-comparison-768x432.png 768w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/b-c-d-curve-options-comparison-1536x864.png 1536w\" sizes=\"auto, (max-width: 1672px) 100vw, 1672px\" \/><figcaption class=\"wp-element-caption\">Conceptuele vergelijking van de B-, C- en D-curves. De aanduiding van de curve is \u00e9\u00e9n selectieparameter en de exacte modeldocumentatie moet worden gecontroleerd.<\/figcaption><\/figure>\n\n\n\n<h2 id=\"mcb-trip-curve\" class=\"wp-block-heading\">Wat is een uitschakelkarakteristiek van een MCB?<\/h2>\n\n\n<p class=\"wp-block-paragraph\">Een MCB beschermt een stroomkring tegen overstroom, maar de manier waarop hij reageert, hangt niet alleen af van zijn nominale stroomsterkte.<\/p>\n<p class=\"wp-block-paragraph\">Een reiskenmerk beschrijft een deel van die reactie.<\/p>\n<p class=\"wp-block-paragraph\">Bij MCB\u2019s van de B-, C- en D-curve is een van de meest opvallende verschillen het bereik voor onmiddellijke of magnetische uitschakeling.<\/p>\n<p class=\"wp-block-paragraph\">Neem twee stroomonderbrekers met dezelfde nominale stroomsterkte.<\/p>\n<p class=\"wp-block-paragraph\">Een B-kromme-beveiliging en een D-kromme-beveiliging kunnen onder normale omstandigheden beide dezelfde nominale stroom geleiden, maar hun momentane uitschakelgebieden kunnen aanzienlijk van elkaar verschillen.<\/p>\n<p class=\"wp-block-paragraph\">Daarom:<\/p>\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p class=\"wp-block-paragraph\">\u201c32A B-curve\u201d en \u201c32A D-curve\u201d duiden niet op hetzelfde beveiligingsgedrag, louter en alleen omdat beide stroomonderbrekers een nominale stroomsterkte van 32 A hebben.<\/p><\/blockquote>\n\n\n<p class=\"wp-block-paragraph\">De curve is dus een extra selectieparameter naast:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>nominaal stroomsterkte<\/li>\n<li>spanning<\/li>\n<li>palen<\/li>\n<li>breekvermogen<\/li>\n<li>montagevorm<\/li>\n<li>precies hetzelfde model<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Zie voor het bredere selectieproces <a href=\"https:\/\/ritoks.com\/nl\/ac-mcb-selection-guide\/\">Keuzegids voor AC-MCB\u2019s: stroomsterkte, polen, uitschakelkarakteristiek en uitschakelvermogen<\/a>.<\/p>\n\n\n\n<h2 id=\"b-curve\" class=\"wp-block-heading\">Wat is een B-curve-stroomonderbreker?<\/h2>\n\n\n<p class=\"wp-block-paragraph\">Bij een B-karakteristiek wordt doorgaans een onmiddellijke uitschakelzone van ongeveer 3 tot 5 keer de nominale stroom gehanteerd.<\/p>\n<p class=\"wp-block-paragraph\">In het algemeen betekent dit dat het momentane magnetische gebied wordt bereikt bij een lager veelvoud van de nominale stroom dan bij C- of D-karakteristieken.<\/p>\n<p class=\"wp-block-paragraph\">In de richtlijnen van de fabrikant worden B-kenmerken doorgaans toegepast in situaties waarin een relatief lage inschakelstroom wordt verwacht.<\/p>\n<p class=\"wp-block-paragraph\">Dat mag echter niet worden omgezet in een regel zoals:<\/p>\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p class=\"wp-block-paragraph\">\u201cAlle verlichtingscircuits moeten gebruikmaken van de B-curve.\u201d<\/p><\/blockquote>\n<p class=\"wp-block-paragraph\">De uiteindelijke keuze hangt af van het circuit, de verwachte inschakelstroom, storingsomstandigheden en de geldende ontwerpvereisten.<\/p>\n\n\n<h3 class=\"wp-block-heading\">Huidige beschikbaarheid van RITOKS B-curves<\/h3>\n\n\n<p class=\"wp-block-paragraph\">Momenteel gepubliceerd <a href=\"https:\/\/ritoks.com\/nl\/product-category\/ac-power-protection\/\">Gegevens over de RITOKS AC-stroomonderbreker<\/a> bevestigt dat de B-curve beschikbaar is op:<\/p>\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/ritoks.com\/nl\/products\/miniature-circuit-breaker-63a-10ka\/\">RTSXD01<\/a> \u2014 B \/ C \/ D<\/li>\n<li>RTSXD03 \u2014 B \/ C<\/li>\n<li><a href=\"https:\/\/ritoks.com\/nl\/products\/1pn-miniature-circuit-breaker-32a-6ka\/\">RTSXD02<\/a> \u2014 B \/ C<\/li>\n<li><a href=\"https:\/\/ritoks.com\/nl\/products\/miniature-circuit-breaker-63a-10ka-pro\/\">RTSXD04<\/a> \u2014 B \/ C \/ D<\/li>\n<li><a href=\"https:\/\/ritoks.com\/nl\/products\/m60-ac-miniature-circuit-breaker-6-63a\/\">RTS-ACM60<\/a> \u2014 B \/ C<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">De reisroute voor de RTS-AC47 is op dit moment nog niet bevestigd.<\/p>\n<p class=\"wp-block-paragraph\">Deze vermeldingen bevestigen uitsluitend de beschikbaarheid. Ze geven geen exacte modelgebonden tijd-stroomverhoudingen weer die verder gaan dan de gepubliceerde curveaanduiding.<\/p>\n\n\n<h2 id=\"c-curve\" class=\"wp-block-heading\">Wat is een MCB met C-kromme?<\/h2>\n\n\n<p class=\"wp-block-paragraph\">Bij een C-karakteristiek wordt doorgaans een onmiddellijke uitschakelzone van ongeveer 5 tot 10 keer de nominale stroom gebruikt.<\/p>\n<p class=\"wp-block-paragraph\">In vergelijking met de B-karakteristiek maakt dit een hogere kortstondige stroomvermenigvuldigingsfactor mogelijk voordat het gebied van de onmiddellijke uitschakeling wordt bereikt.<\/p>\n<p class=\"wp-block-paragraph\">Eaton beschrijft de C-karakteristiek als geschikt voor situaties met een gemiddelde inschakelstroom en noemt als voorbeelden onder meer kleine transformatoren, verlichting, stuurapparatuur, stuurcircuits en spoelen. Dat is nuttige algemene achtergrondinformatie, maar het betekent niet dat voor elk van die toepassingen automatisch een C-karakteristiek vereist is.<\/p>\n\n\n<h3 class=\"wp-block-heading\">Huidige beschikbaarheid van RITOKS C-Curve<\/h3>\n\n<p class=\"wp-block-paragraph\">De C-curve is momenteel de meest algemeen bevestigde curve binnen de gepubliceerde RITOKS AC MCB-families:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>RTSXD01 \u2014 B \/ C \/ D<\/li>\n<li>RTSXD03 \u2014 B \/ C<\/li>\n<li>RTSXD02 \u2014 B \/ C<\/li>\n<li>RTSXD04 \u2014 B \/ C \/ D<\/li>\n<li>RTS-ACM60 \u2014 B \/ C<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">Ook hier geldt dat RTS-AC47 momenteel geen bevestigde curveaanduiding op de website heeft.<\/p>\n\n\n<h2 id=\"d-curve\" class=\"wp-block-heading\">Wat is een MCB met een D-curve?<\/h2>\n\n\n<p class=\"wp-block-paragraph\">Bij een D-karakteristiek wordt doorgaans een onmiddellijke uitschakelzone van ongeveer 10\u201320 keer de nominale stroom gehanteerd.<\/p>\n<p class=\"wp-block-paragraph\">Dit is het hoogste van de drie veelvoorkomende momentane gebieden die hier worden besproken.<\/p>\n<p class=\"wp-block-paragraph\">In de richtlijnen van fabrikanten worden D-kenmerken vaak in verband gebracht met apparatuur met een hoge inschakelstroom. Eaton noemt motoren, transformatoren, voedingen en andere sterk inductieve systemen als typische voorbeelden.<\/p>\n<p class=\"wp-block-paragraph\">Het woord \u2018typisch\u2019 is van belang.<\/p>\n<p class=\"wp-block-paragraph\">Het zou onjuist zijn om te concluderen dat:<\/p>\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p class=\"wp-block-paragraph\">\u201cMotor = D-curve.\u201d<\/p><\/blockquote>\n<p class=\"wp-block-paragraph\">Bij een motorcircuit kunnen veel variabelen een rol spelen, waaronder de startkarakteristieken en het bredere beveiligingsontwerp. De schakelaarkromme moet daarom worden gekozen op basis van geverifieerde technische specificaties en niet louter op basis van de naam van het apparaat.<\/p>\n\n\n<h3 class=\"wp-block-heading\">Huidige beschikbaarheid van de RITOKS D-Curve<\/h3>\n\n<p class=\"wp-block-paragraph\">Uit de recent gepubliceerde RITOKS-gegevens blijkt dat de D-curve geldt voor:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>RTSXD01<\/li>\n<li>RTSXD04<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">Bij de andere momenteel gepubliceerde AC MCB-series wordt op de productpagina\u2019s niet vermeld of er D-curves beschikbaar zijn.<\/p>\n\n\n<h2 id=\"why-curves-differ\" class=\"wp-block-heading\">Waarom de krommen verschillende momentane gebieden gebruiken<\/h2>\n\n\n<p class=\"wp-block-paragraph\">Elektrische apparatuur kan gedurende korte tijd meer stroom verbruiken dan het normale bedrijfsniveau.<\/p>\n<p class=\"wp-block-paragraph\">Dit kan gebeuren tijdens gebeurtenissen zoals het onder spanning zetten of het opstarten.<\/p>\n<p class=\"wp-block-paragraph\">Als het instelbereik voor onmiddellijke uitschakeling van de stroomonderbreker te laag is voor de verwachte kortstondige stroom, kan de stroomonderbreker in werking treden, ook al maakte de gebeurtenis deel uit van het normale opstarten van de apparatuur.<\/p>\n<p class=\"wp-block-paragraph\">Omgekeerd is het niet automatisch beter om zomaar een curve te kiezen met een hoger momentane bereik.<\/p>\n<p class=\"wp-block-paragraph\">Het beveiligingssysteem moet nog steeds op de juiste manier reageren op daadwerkelijke storingen.<\/p>\n<p class=\"wp-block-paragraph\">Daarom moeten de kenmerken B, C en D worden opgevat als verschillende beschermingskenmerken, en niet als kwaliteitsklassen.<\/p>\n<p class=\"wp-block-paragraph\">D is geen \u201cpremium\u201d-versie van C, en C is geen \u201cupgrade\u201d van B.<\/p>\n\n\n<h2 id=\"same-rated-current\" class=\"wp-block-heading\">B versus C versus D bij dezelfde nominale stroomsterkte<\/h2>\n\n\n<p class=\"wp-block-paragraph\">Stel je drie MCB\u2019s voor die allemaal dezelfde nominale stroom, In, hebben.<\/p>\n<p class=\"wp-block-paragraph\">Op basis van de gangbare karakteristieke bereiken:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>B bereikt zijn momentane gebied rond 3\u20135 \u00d7 In<\/li>\n<li>C ongeveer 5\u201310 \u00d7 In<\/li>\n<li>D ongeveer 10\u201320 \u00d7 In<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">Ter illustratie: als In = 10 A, komen die veelvouden wiskundig gezien overeen met:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>B: ongeveer 30\u201350 A<\/li>\n<li>C: ongeveer 50\u2013100 A<\/li>\n<li>D: ongeveer 100\u2013200 A<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">Dit rekenvoorbeeld illustreert alleen de betekenis van de veelvouden. Het is geen aanbeveling voor de keuze van een product en mag niet worden beschouwd als het exacte werkingsgedrag van een specifieke RITOKS-schakelaar.<\/p>\n<p class=\"wp-block-paragraph\">Het daadwerkelijke gedrag van de stroomonderbreker moet worden getoetst aan de exacte tijd-stroomgegevens van de fabrikant en aan de geldende productvereisten.<\/p>\n\n\n<h2 id=\"curve-availability\" class=\"wp-block-heading\">Overzicht van de huidige beschikbaarheid van RITOKS-curves<\/h2>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table><thead><tr><th>RITOKS-model<\/th><th>B<\/th><th>C<\/th><th>D<\/th><th>Huidig bewijs<\/th><\/tr><\/thead><tbody><tr><td>RTSXD01<\/td><td>Ja<\/td><td>Ja<\/td><td>Ja<\/td><td>Gepubliceerde beschikbaarheid<\/td><\/tr><tr><td>RTSXD03<\/td><td>Ja<\/td><td>Ja<\/td><td>\u2014<\/td><td>Gepubliceerde beschikbaarheid<\/td><\/tr><tr><td>RTSXD02<\/td><td>Ja<\/td><td>Ja<\/td><td>\u2014<\/td><td>Gepubliceerde beschikbaarheid<\/td><\/tr><tr><td>RTSXD04<\/td><td>Ja<\/td><td>Ja<\/td><td>Ja<\/td><td>Gepubliceerde beschikbaarheid<\/td><\/tr><tr><td>RTS-ACM60<\/td><td>Ja<\/td><td>Ja<\/td><td>\u2014<\/td><td>Gepubliceerde beschikbaarheid<\/td><\/tr><tr><td>RTS-AC47<\/td><td>Niet bevestigd<\/td><td>Niet bevestigd<\/td><td>Niet bevestigd<\/td><td>Curve niet bevestigd<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n<p class=\"wp-block-paragraph\">Deze tabel mag uitsluitend worden gebruikt voor het opstellen van een shortlist van productfamilies.<\/p>\n<p class=\"wp-block-paragraph\">Dit betekent niet dat de eerder genoemde tijd-stroomcurves van externe fabrikanten de exacte, geteste tijd-stroomcurves van deze RITOKS-modellen zijn.<\/p>\n\n\n<figure data-spectra-id=\"spectra-32eebc39-fcc3-4e9b-a995-f02438bb1b9c\" class=\"wp-block-image aligncenter size-full has-custom-border\" ><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-pole-formats-panel.png\" alt=\"Verschillende poolconfiguraties van miniatuurstroomonderbrekers voor wisselstroom in een industri\u00eble verdeelkast\" class=\"wp-image-703\"  width=\"1672\" height=\"941\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-pole-formats-panel.png 1672w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-pole-formats-panel-600x338.png 600w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-pole-formats-panel-300x169.png 300w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-pole-formats-panel-1024x576.png 1024w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-pole-formats-panel-768x432.png 768w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-pole-formats-panel-1536x864.png 1536w\" sizes=\"auto, (max-width: 1672px) 100vw, 1672px\" \/><figcaption class=\"wp-element-caption\">Voorbeelden van AC-MCB-productuitvoeringen; de beschikbaarheid van de karakteristieke curve en de elektrische specificaties moeten voor het exacte model worden gecontroleerd.<\/figcaption><\/figure>\n\n\n\n<h2 id=\"selection-process\" class=\"wp-block-heading\">Hoe kies je tussen de opties met B-, C- en D-curve?<\/h2>\n\n\n<p class=\"wp-block-paragraph\">Het praktische inkoopproces begint bij de vereiste eigenschap, niet bij een gok op basis van de productnaam.<\/p>\n\n<h3 class=\"wp-block-heading\">1. Controleer de vereisten inzake belasting en inschakelstroom<\/h3>\n<p class=\"wp-block-paragraph\">Ga na of in de projectdocumentatie al het volgende is vastgelegd:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>verwachte aanloopstroom<\/li>\n<li>inschakelgedrag<\/li>\n<li>vereiste kromme<\/li>\n<li>andere beschermingsbeperkingen<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">Als de gewenste curve al is opgegeven, gebruik die dan als uitgangspunt.<\/p>\n\n<h3 class=\"wp-block-heading\">2. Controleer de nominale stroomsterkte<\/h3>\n<p class=\"wp-block-paragraph\">De stroomkarakteristiek en de nominale stroom zijn afzonderlijke parameters.<\/p>\n<p class=\"wp-block-paragraph\">Bijvoorbeeld:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>C16<\/li>\n<li>C32<\/li>\n<li>C63<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">Ze hebben allemaal de aanduiding C, maar hebben verschillende stroomsterktes.<\/p>\n<p class=\"wp-block-paragraph\">Selecteer niet eerst de curve en negeer de vereiste schakelaarstroom niet.<\/p>\n\n<h3 class=\"wp-block-heading\">3. Controleer de breekcapaciteit<\/h3>\n<p class=\"wp-block-paragraph\">Loopcurve en <a href=\"https:\/\/ritoks.com\/nl\/6ka-vs-10ka-mcb-breaking-capacity\/\">6 kA versus 10 kA: uitschakelvermogen van een MCB<\/a> zijn ook verschillende parameters.<\/p>\n<p class=\"wp-block-paragraph\">Een aanduiding A, B, C of D geeft niet aan of de stroomonderbreker:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>6 kA<\/li>\n<li>10 kA<\/li>\n<li>of een andere breekcapaciteit<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">Dat kenmerk moet apart worden gecontroleerd op het betreffende product.<\/p>\n\n<h3 class=\"wp-block-heading\">4. Bevestig de configuratie van de mast<\/h3>\n<p class=\"wp-block-paragraph\">Een vereiste B\/C\/D-curve kan alleen nuttig zijn als dezelfde productfamilie ook het volgende biedt:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>1P<\/li>\n<li>1P+N<\/li>\n<li>2P<\/li>\n<li>3P<\/li>\n<li>3P+N<\/li>\n<li>4P<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">configuratie.<\/p>\n\n<h3 class=\"wp-block-heading\">5. Controleer de exacte productdocumentatie<\/h3>\n<p class=\"wp-block-paragraph\">De laatste stap is het controleren van de geselecteerde stroomonderbreker zelf.<\/p>\n<p class=\"wp-block-paragraph\">Ga er niet zomaar vanuit dat:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>elke B-curve gedraagt zich bij alle fabrikanten op identieke wijze<\/li>\n<li>elke C-kromme heeft identieke tijd-stroomtoleranties<\/li>\n<li>elke D-curve is geschikt voor elke belasting met een hoge inschakelstroom<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">De curveaanduiding vormt een onderdeel van de volledige productspecificatie.<\/p>\n\n\n<h2 id=\"common-mistakes\" class=\"wp-block-heading\">Veelvoorkomende fouten bij de keuze van B\/C\/D-curves<\/h2>\n\n\n<h3 class=\"wp-block-heading\">B, C en D beschouwen als kwaliteitsniveaus<\/h3>\n<p class=\"wp-block-paragraph\">Het gaat om verschillende reiskenmerken, niet om \u201cbasis\u201d, \u201cbeter\u201d en \u201chet beste\u201d.\u201d<\/p>\n\n<h3 class=\"wp-block-heading\">Selecteren op basis van de laadnaam alleen<\/h3>\n<p class=\"wp-block-paragraph\">Uitspraken als \u201cmotor betekent D-curve\u201d zijn te algemeen.<\/p>\n<p class=\"wp-block-paragraph\">Er moet rekening worden gehouden met de verwachte inschakelstroom en het daadwerkelijke elektrische ontwerp.<\/p>\n\n<h3 class=\"wp-block-heading\">De nominale stroom negeren<\/h3>\n<p class=\"wp-block-paragraph\">Een juiste kromme in combinatie met een verkeerde stroomsterkte leidt niet tot de juiste keuze van een stroomonderbreker.<\/p>\n\n<h3 class=\"wp-block-heading\">Het negeren van de breekcapaciteit<\/h3>\n<p class=\"wp-block-paragraph\">De B\/C\/D-karakteristiek en het remvermogen zijn afzonderlijke parameters.<\/p>\n\n<h3 class=\"wp-block-heading\">Ervan uitgaan dat de externe curvegegevens automatisch van toepassing zijn op elk RITOKS-model<\/h3>\n<p class=\"wp-block-paragraph\">De in deze handleiding gebruikte waarden van 3\u20135 \u00d7 In, 5\u201310 \u00d7 In en 10\u201320 \u00d7 In zijn algemene karakteristieke bereiken die worden ondersteund door gezaghebbende technische documentatie van de fabrikant. Op de productpagina\u2019s van RITOKS wordt momenteel aangegeven welke curve-aanduidingen beschikbaar zijn, maar er worden geen volledige modelspecifieke tijd-stroomcurves gepubliceerd.<\/p>\n\n<h3 class=\"wp-block-heading\">Een curvegrafiek maken zonder modelgegevens<\/h3>\n<p class=\"wp-block-paragraph\">Een realistisch ogende grafiek kan de indruk wekken dat de gegevens nauwkeuriger zijn dan op basis van het beschikbare bewijsmateriaal gerechtvaardigd is.<\/p>\n<p class=\"wp-block-paragraph\">Zolang er geen exacte, modelspecifieke tijd-stroomgegevens van RITOKS beschikbaar zijn, moet bij de keuze van de curve worden uitgegaan van de gepubliceerde aanduiding en de projecteisen, en niet van een zelfgemaakte grafiek.<\/p>\n\n\n<h2 id=\"request-technical-data\" class=\"wp-block-heading\">Wanneer moet u om meer technische gegevens vragen?<\/h2>\n\n\n<p class=\"wp-block-paragraph\">Bij een standaardaanvraag voor inkoop kan het voldoende zijn om de vereiste curveaanduiding te kennen om een shortlist van beschikbare modellen op te stellen.<\/p>\n<p class=\"wp-block-paragraph\">Voor een meer gedetailleerde technische beoordeling hebben kopers mogelijk aanvullende documentatie nodig, zoals:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>exacte tijd-stroomkarakteristiek<\/li>\n<li>tolerantie voor onmiddellijke uitschakeling<\/li>\n<li>gegevens over de breekcapaciteit<\/li>\n<li>toepasselijke productnorm<\/li>\n<li>co\u00f6rdinatie-informatie, indien nodig<\/li>\n<li>modelspecifieke test- of certificeringsdocumenten<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">Die vereisten moeten voor het specifieke product worden opgevraagd en mogen niet louter op basis van de letter B, C of D worden verondersteld.<\/p>\n\n\n<h2 id=\"frequently-asked-questions\" class=\"wp-block-heading\">Veelgestelde vragen<\/h2>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Wat is het belangrijkste verschil tussen MCB\u2019s met een B-, C- en D-karakteristiek?<\/summary>\n<p class=\"wp-block-paragraph\">Het belangrijkste verschil dat hier wordt besproken, is het gebied voor onmiddellijke uitschakeling. In de gangbare documentatie van fabrikanten worden waarden van ongeveer 3\u20135 \u00d7 In voor B, 5\u201310 \u00d7 In voor C en 10\u201320 \u00d7 In voor D gebruikt.<\/p>\n<\/details>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Is de C-curve beter dan de B-curve?<\/summary>\n<p class=\"wp-block-paragraph\">Nee. Ze hebben verschillende uitschakelkarakteristieken. De juiste keuze hangt af van het circuit en de verwachte inschakelstroomomstandigheden.<\/p>\n<\/details>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Wordt de D-curve altijd gebruikt voor motoren?<\/summary>\n<p class=\"wp-block-paragraph\">Nee. De D-curve wordt doorgaans geassocieerd met toepassingen met een hogere inschakelstroom, en in de richtlijnen van fabrikanten worden vaak motoren en transformatoren als voorbeelden genoemd, maar de juiste curve hangt af van de daadwerkelijke apparatuur en het ontwerp van de beveiliging.<\/p>\n<\/details>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Biedt RITOKS MCB\u2019s met B-, C- en D-karakteristiek aan?<\/summary>\n<p class=\"wp-block-paragraph\">Ja, voor bepaalde series. Voor de RTSXD01 en RTSXD04 worden momenteel de opties B\/C\/D vermeld. Voor de RTSXD02, RTSXD03 en RTS-ACM60 worden de opties B\/C vermeld. Voor de RTS-AC47 is er momenteel nog geen bevestigde curveaanduiding.<\/p>\n<\/details>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Geeft een Curve-letter de breeksterkte aan?<\/summary>\n<p class=\"wp-block-paragraph\">Nee. De rijkarakteristiek en het remvermogen zijn afzonderlijke productparameters en moeten beide worden gecontroleerd.<\/p>\n<\/details>\n\n\n\n<div class=\"wp-block-group has-ast-global-color-5-color has-ast-global-color-2-background-color has-text-color has-background is-layout-constrained wp-container-core-group-is-layout-737f6912 wp-block-group-is-layout-constrained\" style=\"border-radius:6px;margin-top:48px;padding-top:40px;padding-right:32px;padding-bottom:40px;padding-left:32px\">\n\n\n<h2 class=\"wp-block-heading\">Hulp nodig bij het kiezen van een uitschakelkarakteristiek voor een MCB?<\/h2>\n\n\n<p class=\"wp-block-paragraph\">RITOKS biedt series miniatuurstroomonderbrekers voor wisselstroom aan met verschillende nominale stroomsterktes, poolconfiguraties, onderbrekingsvermogens en beschikbare B\/C\/D-curves.<\/p>\n<p class=\"wp-block-paragraph\">Gebruik een <a href=\"https:\/\/ritoks.com\/nl\/ac-mcb-rfq-checklist\/\">Checklist voor offerteaanvragen voor AC- en MCB-apparatuur<\/a> om het volgende te verstrekken:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>Wisselspanning<\/li>\n<li>vereiste stroomsterkte<\/li>\n<li>poolconfiguratie<\/li>\n<li>vereiste verplaatsingscurve<\/li>\n<li>vereiste breekcapaciteit<\/li>\n<li>hoeveelheid<\/li>\n<li>aanvraag<\/li>\n<li>alle vereiste technische documentatie<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">RITOKS kan de aanvraag vervolgens vergelijken met de momenteel gepubliceerde productfamilies en de bevestigde modelgegevens.<\/p>\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-ast-global-color-0-background-color has-background wp-element-button\" href=\"https:\/\/ritoks.com\/nl\/product-category\/ac-power-protection\/miniature-circuit-breakers\/\">Bekijk AC-miniatuurstroomonderbrekers \u2192<\/a><\/div>\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-ast-global-color-0-background-color has-background wp-element-button\" href=\"https:\/\/ritoks.com\/nl\/ac-mcb-selection-guide\/\">Lees de selectiegids voor AC-stroomonderbrekers (MCB's) \u2192<\/a><\/div>\n<div class=\"wp-block-button is-style-outline is-style-outline--1\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/ritoks.com\/nl\/contact-us\/\">Neem contact op met RITOKS \u2192 Vraag een offerte aan<\/a><\/div>\n<\/div>\n\n\n<\/div>\n\n\n<\/div>","protected":false},"excerpt":{"rendered":"<p>B Curve vs C Curve vs D Curve MCBs: What\u2019s the Difference? B, C and D curves are different tripping [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"no-sidebar","site-content-layout":"page-builder","ast-site-content-layout":"full-width-container","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"disabled","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"disabled","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ritoks_resource_detail_renderer":null,"ritoks_resource_product_cat_term_id":0,"footnotes":""},"categories":[64],"tags":[],"class_list":["post-699","post","type-post","status-publish","format-standard","hentry","category-circuit-protection"],"acf":[],"spectra_blocks_featured_image_url":null,"spectra_blocks_author_info":{"display_name":"RITOKS","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/6d7d0fc73468198f994ab13ef6eb6558c53b6ed1ad86364d5165efe8bdf8eb4a?s=96&d=mm&r=g","author_link":"https:\/\/ritoks.com\/nl\/author\/dazzlingwqbgmail-com\/","description":""},"_links":{"self":[{"href":"https:\/\/ritoks.com\/nl\/wp-json\/wp\/v2\/posts\/699","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ritoks.com\/nl\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ritoks.com\/nl\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ritoks.com\/nl\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/ritoks.com\/nl\/wp-json\/wp\/v2\/comments?post=699"}],"version-history":[{"count":4,"href":"https:\/\/ritoks.com\/nl\/wp-json\/wp\/v2\/posts\/699\/revisions"}],"predecessor-version":[{"id":731,"href":"https:\/\/ritoks.com\/nl\/wp-json\/wp\/v2\/posts\/699\/revisions\/731"}],"wp:attachment":[{"href":"https:\/\/ritoks.com\/nl\/wp-json\/wp\/v2\/media?parent=699"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ritoks.com\/nl\/wp-json\/wp\/v2\/categories?post=699"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ritoks.com\/nl\/wp-json\/wp\/v2\/tags?post=699"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}