{"id":699,"date":"2026-09-05T16:51:06","date_gmt":"2026-09-05T16:51:06","guid":{"rendered":"https:\/\/ritoks.com\/?p=699"},"modified":"2026-09-20T06:54:43","modified_gmt":"2026-09-20T06:54:43","slug":"b-curve-vs-c-curve-vs-d-curve-mcb","status":"publish","type":"post","link":"https:\/\/ritoks.com\/pl\/b-curve-vs-c-curve-vs-d-curve-mcb\/","title":{"rendered":"Wy\u0142\u0105czniki automatyczne o charakterystyce krzywej B, C i D: jaka jest r\u00f3\u017cnica?"},"content":{"rendered":"<div class=\"wp-block-group alignfull has-ast-global-color-5-color has-ast-global-color-2-background-color has-text-color has-background is-layout-constrained wp-container-core-group-is-layout-a2d0cf3a wp-block-group-is-layout-constrained\" style=\"padding-top:64px;padding-right:24px;padding-bottom:64px;padding-left:24px\">\n\n\n<h1 class=\"wp-block-heading\">Wy\u0142\u0105czniki automatyczne o charakterystyce krzywej B, C i D: jaka jest r\u00f3\u017cnica?<\/h1>\n\n\n\n<figure data-spectra-id=\"spectra-0ab2572d-bee2-4067-aa44-af4dcea1142b\" class=\"wp-block-image aligncenter size-full has-custom-border\" ><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-family-hero.png\" alt=\"Typowe serie miniaturowych wy\u0142\u0105cznik\u00f3w pr\u0105du przemiennego w przemys\u0142owym warsztacie elektrycznym\" class=\"wp-image-701\"  width=\"1672\" height=\"941\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-family-hero.png 1672w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-family-hero-600x338.png 600w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-family-hero-300x169.png 300w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-family-hero-1024x576.png 1024w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-family-hero-768x432.png 768w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-family-hero-1536x864.png 1536w\" sizes=\"auto, (max-width: 1672px) 100vw, 1672px\" \/><figcaption class=\"wp-element-caption\">Przyk\u0142adowe formaty wy\u0142\u0105cznik\u00f3w automatycznych pr\u0105du przemiennego (AC MCB) przedstawione w przemys\u0142owym \u015brodowisku elektrycznym.<\/figcaption><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Krzywe B, C i D to r\u00f3\u017cne charakterystyki wyzwalania stosowane w <a href=\"https:\/\/ritoks.com\/pl\/product-category\/ac-power-protection\/miniature-circuit-breakers\/\">miniaturowych wy\u0142\u0105cznik\u00f3w automatycznych (MCB)<\/a>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Litery te nie okre\u015blaj\u0105 aktualnego znamionowego nat\u0119\u017cenia pr\u0105du, zdolno\u015bci wy\u0142\u0105czania ani liczby biegun\u00f3w. Pomagaj\u0105 one natomiast opisa\u0107, w jaki spos\u00f3b wy\u0142\u0105cznik reaguje na wy\u017csze pr\u0105dy kr\u00f3tkotrwa\u0142e w zakresie wy\u0142\u0105czania natychmiastowego.<\/p>\n\n\n<\/div>\n\n\n\n<div class=\"wp-block-group alignfull is-layout-constrained wp-container-core-group-is-layout-105ba9aa wp-block-group-is-layout-constrained\" style=\"padding-top:64px;padding-right:24px;padding-bottom:64px;padding-left:24px\">\n\n\n<p class=\"wp-block-paragraph\">W danych technicznych producenta zazwyczaj podaje si\u0119 nast\u0119puj\u0105ce zakresy parametr\u00f3w:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Krzywa B: oko\u0142o 3\u20135 \u00d7 In<\/li>\n<li>Krzywa C: oko\u0142o 5\u201310 \u00d7 In<\/li>\n<li>Krzywa D: oko\u0142o 10\u201320 \u00d7 In<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">W tym przypadku In oznacza pr\u0105d znamionowy wy\u0142\u0105cznika dla charakterystyki, do kt\u00f3rej si\u0119 odwo\u0142ujemy. <a href=\"https:\/\/www.eaton.com\/content\/dam\/eaton\/support\/apac-support-assets\/japan-cps-assets\/products\/2023promotions_lp\/sccr2024_pdf01.pdf\" target=\"_blank\" rel=\"noopener\">Dokumentacja techniczna firmy Eaton<\/a> podaje te same zakresy reakcji wyzwalania przy zwarciu typu B, C i D dla swoich serii wy\u0142\u0105cznik\u00f3w miniaturowych.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">W praktyce r\u00f3\u017cnica polega na tym, \u017ce te trzy krzywe charakteryzuj\u0105 si\u0119 r\u00f3\u017cn\u0105 odporno\u015bci\u0105 na kr\u00f3tkotrwa\u0142e przep\u0142ywy pr\u0105du, zanim osi\u0105gn\u0105 obszar wyzwalania natychmiastowego.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Nie oznacza to jednak, \u017ce jedna krzywa jest bezwzgl\u0119dnie lepsza od drugiej.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Wymagana krzywa powinna wynika\u0107 z rzeczywistego projektu instalacji elektrycznej, przewidywanych warunk\u00f3w pr\u0105du rozruchowego oraz dokumentacji wybranego wy\u0142\u0105cznika.<\/p>\n\n\n\n<h2 id=\"in-this-guide\" class=\"wp-block-heading\">W niniejszym przewodniku<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"#quick-comparison\">Szybkie por\u00f3wnanie: krzywa B, krzywa C i krzywa D<\/a><\/li>\n<li><a href=\"#mcb-trip-curve\">Czym jest krzywa wyzwalania wy\u0142\u0105cznika r\u00f3\u017cnicowopr\u0105dowego (MCB)?<\/a><\/li>\n<li><a href=\"#b-curve\">Czym jest wy\u0142\u0105cznik nadpr\u0105dowy typu B?<\/a><\/li>\n<li><a href=\"#c-curve\">Czym jest wy\u0142\u0105cznik nadpr\u0105dowy typu C?<\/a><\/li>\n<li><a href=\"#d-curve\">Czym jest wy\u0142\u0105cznik nadpr\u0105dowy typu D?<\/a><\/li>\n<li><a href=\"#curve-availability\">Aktualna dost\u0119pno\u015b\u0107 krzywych RITOKS<\/a><\/li>\n<li><a href=\"#selection-process\">Jak wybra\u0107 opcj\u0119 spo\u015br\u00f3d krzywych B, C i D<\/a><\/li>\n<li><a href=\"#frequently-asked-questions\">Najcz\u0119\u015bciej zadawane pytania<\/a><\/li>\n<\/ul>\n\n\n\n<h2 id=\"quick-comparison\" class=\"wp-block-heading\">Szybkie por\u00f3wnanie: krzywa B, krzywa C i krzywa D<\/h2>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table><thead><tr><th>Charakterystyka<\/th><th>Wsp\u00f3lny obszar wyzwalania natychmiastowego<\/th><th>Og\u00f3lne informacje na temat pr\u0105du rozruchowego<\/th><\/tr><\/thead><tbody><tr><td>Krzywa B<\/td><td>3\u20135 \u00d7 In<\/td><td>Przewidywany ni\u017cszy pr\u0105d rozruchowy<\/td><\/tr><tr><td>Krzywa C<\/td><td>5\u201310 \u00d7 In<\/td><td>Przewiduje si\u0119 umiarkowany pr\u0105d rozruchowy<\/td><\/tr><tr><td>Krzywa D<\/td><td>10\u201320 \u00d7 cala<\/td><td>Przewiduje si\u0119 wy\u017cszy pr\u0105d rozruchowy<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Zakresy te odzwierciedlaj\u0105 og\u00f3lne parametry podane przez g\u0142\u00f3wnych producent\u00f3w wy\u0142\u0105cznik\u00f3w MCB. Nie nale\u017cy ich traktowa\u0107 jako krzywej czasowo-pr\u0105dowej RITOKS charakterystycznej dla konkretnego modelu, chyba \u017ce potwierdza to dok\u0142adna dokumentacja produktu RITOKS.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.eaton.com\/content\/dam\/eaton\/products\/electrical-circuit-protection\/industrial-miniature-circuit-breakers\/Industrial-breakers-catalog-ca08100005e.pdf\" target=\"_blank\" rel=\"noopener\">Wytyczne firmy Eaton dotycz\u0105ce przemys\u0142owych wy\u0142\u0105cznik\u00f3w miniaturowych<\/a>, na przyk\u0142ad, okre\u015bla charakterystyk\u0119 B dla sytuacji o ni\u017cszym pr\u0105dzie rozruchowym, C dla sytuacji o \u015brednim pr\u0105dzie rozruchowym oraz D dla sytuacji o wy\u017cszym pr\u0105dzie rozruchowym. W wytycznych dotycz\u0105cych zastosowa\u0144 podano przyk\u0142ady, takie jak ma\u0142e transformatory i urz\u0105dzenia steruj\u0105ce dla charakterystyki C, a tak\u017ce urz\u0105dzenia o wy\u017cszym pr\u0105dzie rozruchowym, takie jak silniki, transformatory i zasilacze dla charakterystyki D. S\u0105 to typowe przyk\u0142ady, a nie uniwersalne zasady doboru obci\u0105\u017ce\u0144.<\/p>\n\n\n\n<figure data-spectra-id=\"spectra-df209d6b-41f7-4b4c-8253-37ac468fad20\" class=\"wp-block-image aligncenter size-full has-custom-border\" ><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/b-c-d-curve-options-comparison.png\" alt=\"Por\u00f3wnanie koncepcyjne wariant\u00f3w wy\u0142\u0105cznik\u00f3w nadpr\u0105dowych (MCB) o charakterystyce krzywych B, C i D\" class=\"wp-image-702\"  width=\"1672\" height=\"941\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/b-c-d-curve-options-comparison.png 1672w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/b-c-d-curve-options-comparison-600x338.png 600w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/b-c-d-curve-options-comparison-300x169.png 300w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/b-c-d-curve-options-comparison-1024x576.png 1024w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/b-c-d-curve-options-comparison-768x432.png 768w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/b-c-d-curve-options-comparison-1536x864.png 1536w\" sizes=\"auto, (max-width: 1672px) 100vw, 1672px\" \/><figcaption class=\"wp-element-caption\">Por\u00f3wnanie krzywych koncepcyjnych B, C i D. Oznaczenie krzywej stanowi jeden z parametr\u00f3w wyboru, a dok\u0142adn\u0105 dokumentacj\u0119 modelu nale\u017cy zweryfikowa\u0107.<\/figcaption><\/figure>\n\n\n\n<h2 id=\"mcb-trip-curve\" class=\"wp-block-heading\">Czym jest krzywa wyzwalania wy\u0142\u0105cznika r\u00f3\u017cnicowopr\u0105dowego (MCB)?<\/h2>\n\n\n<p class=\"wp-block-paragraph\">Wy\u0142\u0105cznik r\u00f3\u017cnicowopr\u0105dowy (MCB) chroni obw\u00f3d przed nadmiernym nat\u0119\u017ceniem pr\u0105du, ale spos\u00f3b jego dzia\u0142ania zale\u017cy nie tylko od jego warto\u015bci znamionowej w amperach.<\/p>\n<p class=\"wp-block-paragraph\">Cechy charakterystyczne podr\u00f3\u017cy opisuj\u0105 cz\u0119\u015b\u0107 tej reakcji.<\/p>\n<p class=\"wp-block-paragraph\">W przypadku wy\u0142\u0105cznik\u00f3w nadpr\u0105dowych (MCB) o charakterystyce krzywej B, C i D jedn\u0105 z najbardziej zauwa\u017calnych r\u00f3\u017cnic jest zakres wyzwalania natychmiastowego lub magnetycznego.<\/p>\n<p class=\"wp-block-paragraph\">Rozwa\u017cmy dwa wy\u0142\u0105czniki o tej samej warto\u015bci pr\u0105du znamionowego.<\/p>\n<p class=\"wp-block-paragraph\">Wy\u0142\u0105cznik krzywej B i wy\u0142\u0105cznik krzywej D mog\u0105 w normalnych warunkach przewodzi\u0107 ten sam pr\u0105d znamionowy, jednak ich obszary wyzwalania natychmiastowego mog\u0105 si\u0119 znacznie r\u00f3\u017cni\u0107.<\/p>\n<p class=\"wp-block-paragraph\">W\u0142a\u015bnie dlatego:<\/p>\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p class=\"wp-block-paragraph\">\u201cOkre\u015blenia \u201dkrzywa B 32 A\u201c i \u201dkrzywa D 32 A\u201d nie opisuj\u0105 identycznego zachowania zabezpieczaj\u0105cego tylko dlatego, \u017ce oba wy\u0142\u0105czniki maj\u0105 znamionowy pr\u0105d 32 A.<\/p><\/blockquote>\n\n\n<p class=\"wp-block-paragraph\">Krzywa stanowi zatem kolejny parametr selekcyjny obok:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>pr\u0105d znamionowy<\/li>\n<li>napi\u0119cie<\/li>\n<li>s\u0142upy<\/li>\n<li>no\u015bno\u015b\u0107 zrywowa<\/li>\n<li>spos\u00f3b monta\u017cu<\/li>\n<li>dok\u0142adny model<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Aby zapozna\u0107 si\u0119 z szerszym opisem procesu selekcji, zobacz <a href=\"https:\/\/ritoks.com\/pl\/ac-mcb-selection-guide\/\">Przewodnik po doborze wy\u0142\u0105cznik\u00f3w automatycznych pr\u0105du przemiennego (AC MCB): pr\u0105d, liczba biegun\u00f3w, krzywa wyzwalania i zdolno\u015b\u0107 wy\u0142\u0105czania<\/a>.<\/p>\n\n\n\n<h2 id=\"b-curve\" class=\"wp-block-heading\">Czym jest wy\u0142\u0105cznik nadpr\u0105dowy typu B?<\/h2>\n\n\n<p class=\"wp-block-paragraph\">Charakterystyka typu A\u2013B zazwyczaj wykorzystuje obszar wyzwalania natychmiastowego wynosz\u0105cy oko\u0142o 3\u20135-krotno\u015bci pr\u0105du znamionowego.<\/p>\n<p class=\"wp-block-paragraph\">Og\u00f3lnie rzecz bior\u0105c, oznacza to, \u017ce obszar magnetyczny natychmiastowy osi\u0105ga si\u0119 przy ni\u017cszym wielokrotno\u015bci pr\u0105du znamionowego ni\u017c w przypadku charakterystyk typu C lub D.<\/p>\n<p class=\"wp-block-paragraph\">W wytycznych producenta cechy typu B s\u0105 zazwyczaj zalecane w sytuacjach, w kt\u00f3rych spodziewany jest stosunkowo niski pr\u0105d rozruchowy.<\/p>\n<p class=\"wp-block-paragraph\">Nie nale\u017cy jednak przekszta\u0142ca\u0107 tego w regu\u0142\u0119 w postaci:<\/p>\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p class=\"wp-block-paragraph\">\u201cWszystkie obwody o\u015bwietleniowe musz\u0105 wykorzystywa\u0107 krzyw\u0105 B\u201d.\u201d<\/p><\/blockquote>\n<p class=\"wp-block-paragraph\">Ostateczny wyb\u00f3r zale\u017cy od obwodu, przewidywanego pr\u0105du rozruchowego, warunk\u00f3w awaryjnych oraz obowi\u0105zuj\u0105cych wymaga\u0144 projektowych.<\/p>\n\n\n<h3 class=\"wp-block-heading\">Aktualna dost\u0119pno\u015b\u0107 krzywych B firmy RITOKS<\/h3>\n\n\n<p class=\"wp-block-paragraph\">Aktualnie opublikowane <a href=\"https:\/\/ritoks.com\/pl\/product-category\/ac-power-protection\/\">Dane dotycz\u0105ce wy\u0142\u0105cznika r\u00f3\u017cnicowopr\u0105dowego RITOKS AC MCB<\/a> potwierdza dost\u0119pno\u015b\u0107 krzywej B na:<\/p>\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/ritoks.com\/pl\/products\/miniature-circuit-breaker-63a-10ka\/\">RTSXD01<\/a> \u2014 B \/ C \/ D<\/li>\n<li>RTSXD03 \u2014 B \/ C<\/li>\n<li><a href=\"https:\/\/ritoks.com\/pl\/products\/1pn-miniature-circuit-breaker-32a-6ka\/\">RTSXD02<\/a> \u2014 B \/ C<\/li>\n<li><a href=\"https:\/\/ritoks.com\/pl\/products\/miniature-circuit-breaker-63a-10ka-pro\/\">RTSXD04<\/a> \u2014 B \/ C \/ D<\/li>\n<li><a href=\"https:\/\/ritoks.com\/pl\/products\/m60-ac-miniature-circuit-breaker-6-63a\/\">RTS-ACM60<\/a> \u2014 B \/ C<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">Krzywa przebiegu dla modelu RTS-AC47 nie zosta\u0142a na razie potwierdzona.<\/p>\n<p class=\"wp-block-paragraph\">Wpisy te potwierdzaj\u0105 jedynie dost\u0119pno\u015b\u0107. Nie okre\u015blaj\u0105 one dok\u0142adnego przebiegu pr\u0105du w funkcji czasu dla konkretnego modelu poza opublikowanymi danymi dotycz\u0105cymi krzywej.<\/p>\n\n\n<h2 id=\"c-curve\" class=\"wp-block-heading\">Czym jest wy\u0142\u0105cznik nadpr\u0105dowy typu C?<\/h2>\n\n\n<p class=\"wp-block-paragraph\">Charakterystyka typu C zazwyczaj wykorzystuje obszar wyzwalania natychmiastowego wynosz\u0105cy oko\u0142o 5\u201310-krotno\u015bci pr\u0105du znamionowego.<\/p>\n<p class=\"wp-block-paragraph\">W por\u00f3wnaniu z charakterystyk\u0105 typu B umo\u017cliwia to uzyskanie wy\u017cszego wsp\u00f3\u0142czynnika pr\u0105du kr\u00f3tkotrwa\u0142ego przed wej\u015bciem w obszar wyzwalania natychmiastowego.<\/p>\n<p class=\"wp-block-paragraph\">Firma Eaton opisuje charakterystyk\u0119 typu C jako odpowiedni\u0105 do sytuacji, w kt\u00f3rych wyst\u0119puje \u015bredni pr\u0105d rozruchowy, i podaje przyk\u0142ady, takie jak ma\u0142e transformatory, o\u015bwietlenie, urz\u0105dzenia sygnalizacyjne, obwody steruj\u0105ce i cewki. Jest to przydatna og\u00f3lna informacja, ale nie oznacza to, \u017ce ka\u017cde z tych zastosowa\u0144 automatycznie wymaga krzywej typu C.<\/p>\n\n\n<h3 class=\"wp-block-heading\">Aktualna dost\u0119pno\u015b\u0107 produkt\u00f3w RITOKS z serii C-Curve<\/h3>\n\n<p class=\"wp-block-paragraph\">Krzywa C jest obecnie najcz\u0119\u015bciej potwierdzan\u0105 krzyw\u0105 spo\u015br\u00f3d opublikowanych rodzin RITOKS AC MCB:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>RTSXD01 \u2014 B \/ C \/ D<\/li>\n<li>RTSXD03 \u2014 B \/ C<\/li>\n<li>RTSXD02 \u2014 B \/ C<\/li>\n<li>RTSXD04 \u2014 B \/ C \/ D<\/li>\n<li>RTS-ACM60 \u2014 B \/ C<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">Ponownie nale\u017cy zaznaczy\u0107, \u017ce model RTS-AC47 nie ma obecnie potwierdzonego oznaczenia krzywej na stronie.<\/p>\n\n\n<h2 id=\"d-curve\" class=\"wp-block-heading\">Czym jest wy\u0142\u0105cznik nadpr\u0105dowy typu D?<\/h2>\n\n\n<p class=\"wp-block-paragraph\">Charakterystyka typu D zazwyczaj wykorzystuje obszar wyzwalania natychmiastowego wynosz\u0105cy oko\u0142o 10\u201320-krotno\u015b\u0107 pr\u0105du znamionowego.<\/p>\n<p class=\"wp-block-paragraph\">Jest to najwy\u017cszy z trzech om\u00f3wionych tutaj typowych obszar\u00f3w chwilowych.<\/p>\n<p class=\"wp-block-paragraph\">W wytycznych producent\u00f3w parametry charakterystyki D cz\u0119sto kojarzone s\u0105 z urz\u0105dzeniami o wi\u0119kszym pr\u0105dzie rozruchowym. Firma Eaton podaje jako typowe przyk\u0142ady silniki, transformatory, zasilacze i inne uk\u0142ady o wysokiej indukcyjno\u015bci.<\/p>\n<p class=\"wp-block-paragraph\">S\u0142owo \u201etypowy\u201d ma znaczenie.<\/p>\n<p class=\"wp-block-paragraph\">Nie mo\u017cna by bezpiecznie stwierdzi\u0107, \u017ce:<\/p>\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p class=\"wp-block-paragraph\">\u201cSilnik = krzywa D.\u201d<\/p><\/blockquote>\n<p class=\"wp-block-paragraph\">Obw\u00f3d silnikowy mo\u017ce obejmowa\u0107 wiele zmiennych, w tym charakterystyk\u0119 rozruchow\u0105 oraz szersz\u0105 koncepcj\u0119 zabezpiecze\u0144. Krzyw\u0105 wy\u0142\u0105cznika nale\u017cy zatem dobra\u0107 na podstawie zweryfikowanych wymaga\u0144 technicznych, a nie wy\u0142\u0105cznie na podstawie nazwy urz\u0105dzenia.<\/p>\n\n\n<h3 class=\"wp-block-heading\">Aktualna dost\u0119pno\u015b\u0107 krzywych D firmy RITOKS<\/h3>\n\n<p class=\"wp-block-paragraph\">Aktualne, opublikowane dane RITOKS potwierdzaj\u0105 krzyw\u0105 D w odniesieniu do:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>RTSXD01<\/li>\n<li>RTSXD04<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">W przypadku pozosta\u0142ych obecnie dost\u0119pnych na rynku serii wy\u0142\u0105cznik\u00f3w automatycznych AC na stronach produktowych nie ma potwierdzonej informacji o dost\u0119pno\u015bci krzywej D.<\/p>\n\n\n<h2 id=\"why-curves-differ\" class=\"wp-block-heading\">Dlaczego krzywe wykorzystuj\u0105 r\u00f3\u017cne obszary chwilowe<\/h2>\n\n\n<p class=\"wp-block-paragraph\">Urz\u0105dzenia elektryczne mog\u0105 przez kr\u00f3tki czas pobiera\u0107 pr\u0105d o nat\u0119\u017ceniu przekraczaj\u0105cym ich sta\u0142y poziom roboczy.<\/p>\n<p class=\"wp-block-paragraph\">Mo\u017ce to mie\u0107 miejsce podczas takich czynno\u015bci, jak pod\u0142\u0105czenie zasilania lub uruchomienie.<\/p>\n<p class=\"wp-block-paragraph\">Je\u015bli zakres natychmiastowego wyzwalania wy\u0142\u0105cznika jest zbyt niski w stosunku do przewidywanego pr\u0105du kr\u00f3tkotrwa\u0142ego, wy\u0142\u0105cznik mo\u017ce zadzia\u0142a\u0107, mimo \u017ce zdarzenie to by\u0142o cz\u0119\u015bci\u0105 normalnego uruchamiania urz\u0105dzenia.<\/p>\n<p class=\"wp-block-paragraph\">Z drugiej strony samo wybranie krzywej o wi\u0119kszym obszarze chwilowym nie oznacza automatycznie, \u017ce jest ona lepsza.<\/p>\n<p class=\"wp-block-paragraph\">System zabezpiecze\u0144 nadal musi odpowiednio reagowa\u0107 na rzeczywiste usterki.<\/p>\n<p class=\"wp-block-paragraph\">W\u0142a\u015bnie dlatego cechy B, C i D nale\u017cy traktowa\u0107 jako r\u00f3\u017cne cechy ochronne, a nie jako klasy jako\u015bci.<\/p>\n<p class=\"wp-block-paragraph\">J\u0119zyk D nie jest \u201cwersj\u0105 premium\u201d j\u0119zyka C, a j\u0119zyk C nie jest \u201culepszon\u0105 wersj\u0105\u201d j\u0119zyka B.<\/p>\n\n\n<h2 id=\"same-rated-current\" class=\"wp-block-heading\">B kontra C kontra D przy tym samym pr\u0105dzie znamionowym<\/h2>\n\n\n<p class=\"wp-block-paragraph\">Wyobra\u017amy sobie trzy wy\u0142\u0105czniki automatyczne, kt\u00f3re maj\u0105 ten sam pr\u0105d znamionowy In.<\/p>\n<p class=\"wp-block-paragraph\">Wykorzystuj\u0105c typowe zakresy warto\u015bci:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>B osi\u0105ga sw\u00f3j obszar chwilowy w przedziale oko\u0142o 3\u20135 \u00d7 In<\/li>\n<li>C oko\u0142o 5\u201310 \u00d7 In<\/li>\n<li>D oko\u0142o 10\u201320 \u00d7 In<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">Tylko dla przyk\u0142adu: je\u015bli In = 10 A, to te wielokrotno\u015bci odpowiadaj\u0105 matematycznie:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>B: oko\u0142o 30\u201350 A<\/li>\n<li>C: oko\u0142o 50\u2013100 A<\/li>\n<li>D: oko\u0142o 100\u2013200 A<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">Ten przyk\u0142ad arytmetyczny s\u0142u\u017cy jedynie zilustrowaniu znaczenia wielokrotno\u015bci. Nie stanowi on rekomendacji dotycz\u0105cej doboru produktu i nie nale\u017cy go traktowa\u0107 jako dok\u0142adnego opisu dzia\u0142ania konkretnego wy\u0142\u0105cznika RITOKS.<\/p>\n<p class=\"wp-block-paragraph\">Rzeczywiste zachowanie wy\u0142\u0105cznika nale\u017cy zweryfikowa\u0107 w oparciu o dok\u0142adn\u0105 dokumentacj\u0119 producenta dotycz\u0105c\u0105 zale\u017cno\u015bci czasowo-pr\u0105dowej oraz obowi\u0105zuj\u0105ce wymagania dotycz\u0105ce produktu.<\/p>\n\n\n<h2 id=\"curve-availability\" class=\"wp-block-heading\">Aktualna dost\u0119pno\u015b\u0107 krzywych RITOKS w skr\u00f3cie<\/h2>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table><thead><tr><th>Model RITOKS<\/th><th>B<\/th><th>C<\/th><th>D<\/th><th>Aktualne dane naukowe<\/th><\/tr><\/thead><tbody><tr><td>RTSXD01<\/td><td>Tak<\/td><td>Tak<\/td><td>Tak<\/td><td>Opublikowana dost\u0119pno\u015b\u0107<\/td><\/tr><tr><td>RTSXD03<\/td><td>Tak<\/td><td>Tak<\/td><td>\u2014<\/td><td>Opublikowana dost\u0119pno\u015b\u0107<\/td><\/tr><tr><td>RTSXD02<\/td><td>Tak<\/td><td>Tak<\/td><td>\u2014<\/td><td>Opublikowana dost\u0119pno\u015b\u0107<\/td><\/tr><tr><td>RTSXD04<\/td><td>Tak<\/td><td>Tak<\/td><td>Tak<\/td><td>Opublikowana dost\u0119pno\u015b\u0107<\/td><\/tr><tr><td>RTS-ACM60<\/td><td>Tak<\/td><td>Tak<\/td><td>\u2014<\/td><td>Opublikowana dost\u0119pno\u015b\u0107<\/td><\/tr><tr><td>RTS-AC47<\/td><td>Niepotwierdzone<\/td><td>Niepotwierdzone<\/td><td>Niepotwierdzone<\/td><td>Krzywa nie zosta\u0142a potwierdzona<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n<p class=\"wp-block-paragraph\">Tabela ta powinna s\u0142u\u017cy\u0107 wy\u0142\u0105cznie do wst\u0119pnej selekcji rodzin produkt\u00f3w.<\/p>\n<p class=\"wp-block-paragraph\">Nie oznacza to, \u017ce przytoczone wcze\u015bniej krzywe zewn\u0119trznego producenta s\u0105 dok\u0142adnymi, sprawdzonymi krzywymi czasowo-pr\u0105dowymi tych modeli RITOKS.<\/p>\n\n\n<figure data-spectra-id=\"spectra-b44e8d02-c60f-4ce0-b8f8-cb9a79974430\" class=\"wp-block-image aligncenter size-full has-custom-border\" ><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-pole-formats-panel.png\" alt=\"R\u00f3\u017cne uk\u0142ady biegun\u00f3w miniaturowych wy\u0142\u0105cznik\u00f3w pr\u0105du przemiennego w przemys\u0142owej rozdzielnicy\" class=\"wp-image-703\"  width=\"1672\" height=\"941\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-pole-formats-panel.png 1672w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-pole-formats-panel-600x338.png 600w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-pole-formats-panel-300x169.png 300w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-pole-formats-panel-1024x576.png 1024w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-pole-formats-panel-768x432.png 768w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-pole-formats-panel-1536x864.png 1536w\" sizes=\"auto, (max-width: 1672px) 100vw, 1672px\" \/><figcaption class=\"wp-element-caption\">Przyk\u0142adowe wersje wy\u0142\u0105cznik\u00f3w r\u00f3\u017cnicowopr\u0105dowych (MCB) firmy AC; dost\u0119pno\u015b\u0107 charakterystyk oraz parametry elektryczne nale\u017cy sprawdzi\u0107 dla konkretnego modelu.<\/figcaption><\/figure>\n\n\n\n<h2 id=\"selection-process\" class=\"wp-block-heading\">Jak wybra\u0107 opcj\u0119 spo\u015br\u00f3d krzywych B, C i D<\/h2>\n\n\n<p class=\"wp-block-paragraph\">Praktyczny proces doboru produkt\u00f3w zaczyna si\u0119 od wymaganej cechy, a nie od przypuszcze\u0144 opartych na nazwie produktu.<\/p>\n\n<h3 class=\"wp-block-heading\">1. Sprawd\u017a wymagania dotycz\u0105ce obci\u0105\u017cenia i pr\u0105du rozruchowego<\/h3>\n<p class=\"wp-block-paragraph\">Nale\u017cy ustali\u0107, czy w dokumentacji projektu okre\u015blono ju\u017c:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>przewidywany pr\u0105d rozruchowy<\/li>\n<li>charakterystyka pr\u0105du rozruchowego<\/li>\n<li>krzywa wymagana<\/li>\n<li>inne ograniczenia zwi\u0105zane z ochron\u0105<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">Je\u015bli wymagana krzywa zosta\u0142a ju\u017c okre\u015blona, nale\u017cy j\u0105 potraktowa\u0107 jako punkt wyj\u015bcia.<\/p>\n\n<h3 class=\"wp-block-heading\">2. Sprawd\u017a pr\u0105d znamionowy<\/h3>\n<p class=\"wp-block-paragraph\">Krzywa wy\u0142\u0105czania i pr\u0105d znamionowy to odr\u0119bne parametry.<\/p>\n<p class=\"wp-block-paragraph\">Na przyk\u0142ad:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>C16<\/li>\n<li>C32<\/li>\n<li>C63<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">wszystkie maj\u0105 oznaczenie \u201eC\u201d, ale charakteryzuj\u0105 si\u0119 r\u00f3\u017cnymi warto\u015bciami nat\u0119\u017cenia pr\u0105du.<\/p>\n<p class=\"wp-block-paragraph\">Nie nale\u017cy najpierw wybiera\u0107 krzywej i pomija\u0107 wymaganego pr\u0105du wyzwalaj\u0105cego.<\/p>\n\n<h3 class=\"wp-block-heading\">3. Sprawd\u017a wytrzyma\u0142o\u015b\u0107 na zerwanie<\/h3>\n<p class=\"wp-block-paragraph\">Krzywa przebiegu i <a href=\"https:\/\/ritoks.com\/pl\/6ka-vs-10ka-mcb-breaking-capacity\/\">Zdolno\u015b\u0107 wy\u0142\u0105czania wy\u0142\u0105cznik\u00f3w kompaktowych (MCB) o warto\u015bci 6 kA w por\u00f3wnaniu z 10 kA<\/a> s\u0105 to r\u00f3wnie\u017c r\u00f3\u017cne parametry.<\/p>\n<p class=\"wp-block-paragraph\">Oznaczenie A, B, C lub D nie wskazuje, czy wy\u0142\u0105cznik posiada:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>6 kA<\/li>\n<li>10 kA<\/li>\n<li>lub inn\u0105 warto\u015b\u0107 no\u015bno\u015bci<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">T\u0119 cech\u0119 nale\u017cy sprawdzi\u0107 osobno dla konkretnego produktu.<\/p>\n\n<h3 class=\"wp-block-heading\">4. Potwierd\u017a konfiguracj\u0119 s\u0142up\u00f3w<\/h3>\n<p class=\"wp-block-paragraph\">Wymagana krzywa B\/C\/D mo\u017ce okaza\u0107 si\u0119 przydatna tylko wtedy, gdy ta sama rodzina produkt\u00f3w oferuje r\u00f3wnie\u017c nast\u0119puj\u0105ce wymagane cechy:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>1P<\/li>\n<li>1P+N<\/li>\n<li>2P<\/li>\n<li>3P<\/li>\n<li>3P+N<\/li>\n<li>4P<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">konfiguracja.<\/p>\n\n<h3 class=\"wp-block-heading\">5. Sprawd\u017a dok\u0142adn\u0105 dokumentacj\u0119 produktu<\/h3>\n<p class=\"wp-block-paragraph\">Ostatnim krokiem jest sprawdzenie samego wybranego wy\u0142\u0105cznika.<\/p>\n<p class=\"wp-block-paragraph\">Nie nale\u017cy zak\u0142ada\u0107, \u017ce:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>ka\u017cda krzywa typu B zachowuje si\u0119 identycznie u wszystkich producent\u00f3w<\/li>\n<li>ka\u017cda krzywa typu C charakteryzuje si\u0119 identycznymi tolerancjami czasowo-pr\u0105dowymi<\/li>\n<li>ka\u017cda krzywa typu D nadaje si\u0119 do ka\u017cdego obci\u0105\u017cenia o du\u017cym pr\u0105dzie rozruchowym<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">Oznaczenie krzywej stanowi cz\u0119\u015b\u0107 pe\u0142nej specyfikacji produktu.<\/p>\n\n\n<h2 id=\"common-mistakes\" class=\"wp-block-heading\">Typowe b\u0142\u0119dy przy doborze krzywej B\/C\/D<\/h2>\n\n\n<h3 class=\"wp-block-heading\">Traktowanie poziom\u00f3w B, C i D jako poziom\u00f3w jako\u015bci<\/h3>\n<p class=\"wp-block-paragraph\">S\u0105 to r\u00f3\u017cne cechy podr\u00f3\u017cy, a nie \u201cpodstawowe\u201d, \u201clepsze\u201d i \u201cnajlepsze\u201d.\u201d<\/p>\n\n<h3 class=\"wp-block-heading\">Wybieranie wy\u0142\u0105cznie na podstawie nazwy \u0142adunku<\/h3>\n<p class=\"wp-block-paragraph\">Stwierdzenia takie jak \u201csilnik oznacza krzyw\u0105 D\u201d s\u0105 zbyt og\u00f3lne.<\/p>\n<p class=\"wp-block-paragraph\">Nale\u017cy uwzgl\u0119dni\u0107 przewidywany pr\u0105d rozruchowy oraz rzeczywist\u0105 konstrukcj\u0119 elektryczn\u0105.<\/p>\n\n<h3 class=\"wp-block-heading\">Nie uwzgl\u0119dnianie pr\u0105du znamionowego<\/h3>\n<p class=\"wp-block-paragraph\">Odpowiednia krzywa w po\u0142\u0105czeniu z niew\u0142a\u015bciw\u0105 warto\u015bci\u0105 pr\u0105du znamionowego nie oznacza w\u0142a\u015bciwego doboru wy\u0142\u0105cznika.<\/p>\n\n<h3 class=\"wp-block-heading\">Nie uwzgl\u0119dnianie obci\u0105\u017calno\u015bci granicznej<\/h3>\n<p class=\"wp-block-paragraph\">Charakterystyka B\/C\/D i zdolno\u015b\u0107 hamowania to odr\u0119bne parametry.<\/p>\n\n<h3 class=\"wp-block-heading\">Za\u0142o\u017cenie, \u017ce dane krzywych zewn\u0119trznych maj\u0105 automatycznie zastosowanie do ka\u017cdego modelu RITOKS<\/h3>\n<p class=\"wp-block-paragraph\">Warto\u015bci 3\u20135 \u00d7 In, 5\u201310 \u00d7 In i 10\u201320 \u00d7 In podane w niniejszym przewodniku stanowi\u0105 og\u00f3lne zakresy charakterystyk potwierdzone przez wiarygodn\u0105 literatur\u0119 techniczn\u0105 producent\u00f3w. Na stronach produkt\u00f3w firmy RITOKS podano aktualnie dost\u0119pne oznaczenia krzywych, jednak nie opublikowano tam pe\u0142nych krzywych czasowo-pr\u0105dowych dla poszczeg\u00f3lnych modeli.<\/p>\n\n<h3 class=\"wp-block-heading\">Tworzenie wykresu krzywej bez danych modelowych<\/h3>\n<p class=\"wp-block-paragraph\">Wykres o realistycznym wygl\u0105dzie mo\u017ce sugerowa\u0107 wi\u0119ksz\u0105 precyzj\u0119, ni\u017c wynika to z dost\u0119pnych dowod\u00f3w.<\/p>\n<p class=\"wp-block-paragraph\">Dop\u00f3ki nie b\u0119d\u0105 dost\u0119pne dok\u0142adne dane dotycz\u0105ce zale\u017cno\u015bci czasowo-pr\u0105dowych dla konkretnego modelu RITOKS, wyb\u00f3r krzywej powinien opiera\u0107 si\u0119 na opublikowanej oznaczeniu i wymaganiach projektowych, a nie na samodzielnie sporz\u0105dzonym wykresie.<\/p>\n\n\n<h2 id=\"request-technical-data\" class=\"wp-block-heading\">Kiedy nale\u017cy poprosi\u0107 o dodatkowe dane techniczne?<\/h2>\n\n\n<p class=\"wp-block-paragraph\">W przypadku rutynowego zapytania ofertowego znajomo\u015b\u0107 wymaganego oznaczenia krzywej mo\u017ce wystarczy\u0107 do zaw\u0119\u017cenia listy dost\u0119pnych modeli.<\/p>\n<p class=\"wp-block-paragraph\">W celu przeprowadzenia bardziej szczeg\u00f3\u0142owej analizy technicznej nabywcy mog\u0105 potrzebowa\u0107 dodatkowej dokumentacji, takiej jak:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>dok\u0142adna charakterystyka czasowo-pr\u0105dowa<\/li>\n<li>tolerancja wyzwalania natychmiastowego<\/li>\n<li>dane dotycz\u0105ce obci\u0105\u017calno\u015bci maksymalnej<\/li>\n<li>obowi\u0105zuj\u0105ca norma produktowa<\/li>\n<li>informacje dotycz\u0105ce koordynacji, je\u015bli s\u0105 wymagane<\/li>\n<li>dokumenty dotycz\u0105ce bada\u0144 lub certyfikacji konkretnych modeli<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">Wymagania te nale\u017cy ustali\u0107 w odniesieniu do konkretnego produktu, a nie opiera\u0107 si\u0119 wy\u0142\u0105cznie na literach B, C lub D.<\/p>\n\n\n<h2 id=\"frequently-asked-questions\" class=\"wp-block-heading\">Najcz\u0119\u015bciej zadawane pytania<\/h2>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Jaka jest g\u0142\u00f3wna r\u00f3\u017cnica mi\u0119dzy wy\u0142\u0105cznikami nadpr\u0105dowymi typu B, C i D?<\/summary>\n<p class=\"wp-block-paragraph\">G\u0142\u00f3wn\u0105 r\u00f3\u017cnic\u0105, o kt\u00f3rej tutaj mowa, jest obszar wyzwalania natychmiastowego. W typowej dokumentacji producent\u00f3w stosuje si\u0119 warto\u015bci rz\u0119du oko\u0142o 3\u20135 \u00d7 In dla typu B, 5\u201310 \u00d7 In dla typu C oraz 10\u201320 \u00d7 In dla typu D.<\/p>\n<\/details>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Czy krzywa C jest lepsza od krzywej B?<\/summary>\n<p class=\"wp-block-paragraph\">Nie. Maj\u0105 one r\u00f3\u017cne charakterystyki wyzwalania. W\u0142a\u015bciwy wyb\u00f3r zale\u017cy od obwodu i przewidywanych warunk\u00f3w pr\u0105du rozruchowego.<\/p>\n<\/details>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Czy krzywa D jest zawsze stosowana w silnikach?<\/summary>\n<p class=\"wp-block-paragraph\">Nie. Krzywa typu D jest zazwyczaj kojarzona z zastosowaniami o wy\u017cszym pr\u0105dzie rozruchowym, a w wytycznych producent\u00f3w jako przyk\u0142ady cz\u0119sto podaje si\u0119 silniki i transformatory, jednak w\u0142a\u015bciwa krzywa zale\u017cy od konkretnego sprz\u0119tu i konstrukcji zabezpieczenia.<\/p>\n<\/details>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Czy firma RITOKS ma w swojej ofercie wy\u0142\u0105czniki r\u00f3\u017cnicowopr\u0105dowe z charakterystyk\u0105 B, C i D?<\/summary>\n<p class=\"wp-block-paragraph\">Tak, w przypadku wybranych serii. Modele RTSXD01 i RTSXD04 maj\u0105 obecnie w ofercie opcje B\/C\/D. Modele RTSXD02, RTSXD03 i RTS-ACM60 maj\u0105 w ofercie opcje B\/C. Model RTS-AC47 nie ma obecnie potwierdzonego oznaczenia krzywej.<\/p>\n<\/details>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Czy na tabliczce z krzywk\u0105 podana jest wytrzyma\u0142o\u015b\u0107 na zerwanie?<\/summary>\n<p class=\"wp-block-paragraph\">Nie. Charakterystyka skoku i si\u0142a hamowania to odr\u0119bne parametry produktu i nale\u017cy sprawdzi\u0107 oba.<\/p>\n<\/details>\n\n\n\n<div class=\"wp-block-group has-ast-global-color-5-color has-ast-global-color-2-background-color has-text-color has-background is-layout-constrained wp-container-core-group-is-layout-737f6912 wp-block-group-is-layout-constrained\" style=\"border-radius:6px;margin-top:48px;padding-top:40px;padding-right:32px;padding-bottom:40px;padding-left:32px\">\n\n\n<h2 class=\"wp-block-heading\">Potrzebujesz pomocy przy wyborze charakterystyki wyzwalania wy\u0142\u0105cznika nadpr\u0105dowego (MCB)?<\/h2>\n\n\n<p class=\"wp-block-paragraph\">Firma RITOKS oferuje serie miniaturowych wy\u0142\u0105cznik\u00f3w pr\u0105du przemiennego o r\u00f3\u017cnych warto\u015bciach znamionowych pr\u0105du, konfiguracjach biegun\u00f3w, zdolno\u015bciach wy\u0142\u0105czania oraz z dost\u0119pno\u015bci\u0105 krzywych B\/C\/D.<\/p>\n<p class=\"wp-block-paragraph\">U\u017cyj <a href=\"https:\/\/ritoks.com\/pl\/ac-mcb-rfq-checklist\/\">Lista kontrolna zapytania ofertowego dotycz\u0105cego wy\u0142\u0105cznik\u00f3w automatycznych pr\u0105du przemiennego (AC MCB)<\/a> w celu zapewnienia:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>Napi\u0119cie pr\u0105du przemiennego<\/li>\n<li>wymagany pr\u0105d<\/li>\n<li>konfiguracja s\u0142up\u00f3w<\/li>\n<li>wymagana krzywa przebiegu<\/li>\n<li>wymagana wydajno\u015b\u0107 hamowania<\/li>\n<li>ilo\u015b\u0107<\/li>\n<li>wniosek<\/li>\n<li>wszelka wymagana dokumentacja techniczna<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">RITOKS mo\u017ce nast\u0119pnie dopasowa\u0107 zapytanie do aktualnie opublikowanych rodzin produkt\u00f3w oraz potwierdzonych danych dotycz\u0105cych modeli.<\/p>\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-ast-global-color-0-background-color has-background wp-element-button\" href=\"https:\/\/ritoks.com\/pl\/product-category\/ac-power-protection\/miniature-circuit-breakers\/\">Zobacz miniaturowe wy\u0142\u0105czniki pr\u0105du przemiennego \u2192<\/a><\/div>\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-ast-global-color-0-background-color has-background wp-element-button\" href=\"https:\/\/ritoks.com\/pl\/ac-mcb-selection-guide\/\">Przeczytaj przewodnik po doborze wy\u0142\u0105cznik\u00f3w automatycznych pr\u0105du przemiennego \u2192<\/a><\/div>\n<div class=\"wp-block-button is-style-outline is-style-outline--1\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/ritoks.com\/pl\/contact-us\/\">Skontaktuj si\u0119 z RITOKS \u2192 Popro\u015b o wycen\u0119<\/a><\/div>\n<\/div>\n\n\n<\/div>\n\n\n<\/div>","protected":false},"excerpt":{"rendered":"<p>B Curve vs C Curve vs D Curve MCBs: What\u2019s the Difference? B, C and D curves are different tripping [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"no-sidebar","site-content-layout":"page-builder","ast-site-content-layout":"full-width-container","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"disabled","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"disabled","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ritoks_resource_detail_renderer":null,"ritoks_resource_product_cat_term_id":0,"footnotes":""},"categories":[64],"tags":[],"class_list":["post-699","post","type-post","status-publish","format-standard","hentry","category-circuit-protection"],"acf":[],"spectra_blocks_featured_image_url":null,"spectra_blocks_author_info":{"display_name":"RITOKS","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/6d7d0fc73468198f994ab13ef6eb6558c53b6ed1ad86364d5165efe8bdf8eb4a?s=96&d=mm&r=g","author_link":"https:\/\/ritoks.com\/pl\/author\/dazzlingwqbgmail-com\/","description":""},"_links":{"self":[{"href":"https:\/\/ritoks.com\/pl\/wp-json\/wp\/v2\/posts\/699","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ritoks.com\/pl\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ritoks.com\/pl\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ritoks.com\/pl\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/ritoks.com\/pl\/wp-json\/wp\/v2\/comments?post=699"}],"version-history":[{"count":4,"href":"https:\/\/ritoks.com\/pl\/wp-json\/wp\/v2\/posts\/699\/revisions"}],"predecessor-version":[{"id":731,"href":"https:\/\/ritoks.com\/pl\/wp-json\/wp\/v2\/posts\/699\/revisions\/731"}],"wp:attachment":[{"href":"https:\/\/ritoks.com\/pl\/wp-json\/wp\/v2\/media?parent=699"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ritoks.com\/pl\/wp-json\/wp\/v2\/categories?post=699"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ritoks.com\/pl\/wp-json\/wp\/v2\/tags?post=699"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}