{"id":699,"date":"2026-09-05T16:51:06","date_gmt":"2026-09-05T16:51:06","guid":{"rendered":"https:\/\/ritoks.com\/?p=699"},"modified":"2026-09-20T06:54:43","modified_gmt":"2026-09-20T06:54:43","slug":"b-curve-vs-c-curve-vs-d-curve-mcb","status":"publish","type":"post","link":"https:\/\/ritoks.com\/pt-br\/b-curve-vs-c-curve-vs-d-curve-mcb\/","title":{"rendered":"Disjuntores autom\u00e1ticos (MCBs) de curva B, curva C e curva D: qual \u00e9 a diferen\u00e7a?"},"content":{"rendered":"<div class=\"wp-block-group alignfull has-ast-global-color-5-color has-ast-global-color-2-background-color has-text-color has-background is-layout-constrained wp-container-core-group-is-layout-a2d0cf3a wp-block-group-is-layout-constrained\" style=\"padding-top:64px;padding-right:24px;padding-bottom:64px;padding-left:24px\">\n\n\n<h1 class=\"wp-block-heading\">Disjuntores autom\u00e1ticos (MCBs) de curva B, curva C e curva D: qual \u00e9 a diferen\u00e7a?<\/h1>\n\n\n\n<figure data-spectra-id=\"spectra-decdfeea-7c7f-4395-8dfd-338e5b08af11\" class=\"wp-block-image aligncenter size-full has-custom-border\" ><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-family-hero.png\" alt=\"Fam\u00edlias representativas de disjuntores miniatura CA em uma oficina el\u00e9trica industrial\" class=\"wp-image-701\"  width=\"1672\" height=\"941\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-family-hero.png 1672w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-family-hero-600x338.png 600w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-family-hero-300x169.png 300w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-family-hero-1024x576.png 1024w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-family-hero-768x432.png 768w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-family-hero-1536x864.png 1536w\" sizes=\"auto, (max-width: 1672px) 100vw, 1672px\" \/><figcaption class=\"wp-element-caption\">Formatos representativos de disjuntores CA (MCB) apresentados em um ambiente el\u00e9trico industrial.<\/figcaption><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">As curvas B, C e D representam diferentes caracter\u00edsticas de disparo utilizadas com <a href=\"https:\/\/ritoks.com\/pt-br\/product-category\/ac-power-protection\/miniature-circuit-breakers\/\">disjuntores miniatura (MCBs)<\/a>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">As letras n\u00e3o indicam a classifica\u00e7\u00e3o atual, a capacidade de interrup\u00e7\u00e3o ou o n\u00famero de polos. Em vez disso, elas ajudam a descrever como o disjuntor responde a correntes de alta intensidade e curta dura\u00e7\u00e3o em sua faixa de disparo instant\u00e2neo.<\/p>\n\n\n<\/div>\n\n\n\n<div class=\"wp-block-group alignfull is-layout-constrained wp-container-core-group-is-layout-105ba9aa wp-block-group-is-layout-constrained\" style=\"padding-top:64px;padding-right:24px;padding-bottom:64px;padding-left:24px\">\n\n\n<p class=\"wp-block-paragraph\">Os dados t\u00e9cnicos do fabricante geralmente indicam os seguintes intervalos de caracter\u00edsticas:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Curva B: aproximadamente 3\u20135 \u00d7 In<\/li>\n<li>Curva C: aproximadamente 5\u201310 \u00d7 In<\/li>\n<li>Curva D: aproximadamente 10\u201320 \u00d7 In<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Aqui, In representa a corrente nominal do disjuntor para a caracter\u00edstica em quest\u00e3o. <a href=\"https:\/\/www.eaton.com\/content\/dam\/eaton\/support\/apac-support-assets\/japan-cps-assets\/products\/2023promotions_lp\/sccr2024_pdf01.pdf\" target=\"_blank\" rel=\"noopener\">Documenta\u00e7\u00e3o t\u00e9cnica da Eaton<\/a> divulga essas mesmas faixas de resposta de disparo em caso de curto-circuito (B, C e D) para suas fam\u00edlias de disjuntores miniatura.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A diferen\u00e7a pr\u00e1tica \u00e9 que as tr\u00eas curvas suportam n\u00edveis diferentes de corrente de curta dura\u00e7\u00e3o antes de atingirem a regi\u00e3o de desligamento instant\u00e2neo.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Isso n\u00e3o significa que uma curva seja, de maneira geral, melhor do que outra.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A curva necess\u00e1ria deve ser determinada com base no projeto el\u00e9trico efetivo, nas condi\u00e7\u00f5es de corrente de irrup\u00e7\u00e3o previstas e na documenta\u00e7\u00e3o do disjuntor que est\u00e1 sendo selecionado.<\/p>\n\n\n\n<h2 id=\"in-this-guide\" class=\"wp-block-heading\">Neste guia<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"#quick-comparison\">Compara\u00e7\u00e3o r\u00e1pida: Curva B x Curva C x Curva D<\/a><\/li>\n<li><a href=\"#mcb-trip-curve\">O que \u00e9 uma curva de disparo de um disjuntor?<\/a><\/li>\n<li><a href=\"#b-curve\">O que \u00e9 um disjuntor de curva B?<\/a><\/li>\n<li><a href=\"#c-curve\">O que \u00e9 um disjuntor de curva C?<\/a><\/li>\n<li><a href=\"#d-curve\">O que \u00e9 um disjuntor de curva D?<\/a><\/li>\n<li><a href=\"#curve-availability\">Disponibilidade atual da curva RITOKS<\/a><\/li>\n<li><a href=\"#selection-process\">Como escolher entre as op\u00e7\u00f5es de curvas B, C e D<\/a><\/li>\n<li><a href=\"#frequently-asked-questions\">Perguntas frequentes<\/a><\/li>\n<\/ul>\n\n\n\n<h2 id=\"quick-comparison\" class=\"wp-block-heading\">Compara\u00e7\u00e3o r\u00e1pida: Curva B x Curva C x Curva D<\/h2>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table><thead><tr><th>Caracter\u00edstica<\/th><th>Regi\u00e3o de disparo instant\u00e2neo comum<\/th><th>Contexto geral da corrente de irrup\u00e7\u00e3o<\/th><\/tr><\/thead><tbody><tr><td>Curva B<\/td><td>3\u20135 \u00d7 em<\/td><td>Corrente de irrup\u00e7\u00e3o esperada menor<\/td><\/tr><tr><td>Curva C<\/td><td>5\u201310 \u00d7 em<\/td><td>Prev\u00ea-se um pico de corrente moderado<\/td><\/tr><tr><td>Curva D<\/td><td>10\u201320 \u00d7 pol.<\/td><td>Espera-se um pico de corrente de entrada mais alto<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Essas faixas descrevem as caracter\u00edsticas gerais documentadas pelos principais fabricantes de MCBs. Elas n\u00e3o devem ser consideradas como uma curva tempo-corrente RITOKS espec\u00edfica de um modelo, a menos que a documenta\u00e7\u00e3o exata do produto RITOKS confirme isso.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.eaton.com\/content\/dam\/eaton\/products\/electrical-circuit-protection\/industrial-miniature-circuit-breakers\/Industrial-breakers-catalog-ca08100005e.pdf\" target=\"_blank\" rel=\"noopener\">Guia sobre disjuntores industriais miniatura da Eaton<\/a>, por exemplo, descreve a caracter\u00edstica B para situa\u00e7\u00f5es de corrente de irrup\u00e7\u00e3o mais baixa, a caracter\u00edstica C para situa\u00e7\u00f5es de corrente de irrup\u00e7\u00e3o m\u00e9dia e a caracter\u00edstica D para situa\u00e7\u00f5es de corrente de irrup\u00e7\u00e3o mais alta. Seu guia de aplica\u00e7\u00e3o fornece exemplos como pequenos transformadores e equipamentos de controle para a caracter\u00edstica C, e equipamentos com picos de corrente mais elevados, como motores, transformadores e fontes de alimenta\u00e7\u00e3o, para a caracter\u00edstica D. Esses s\u00e3o exemplos t\u00edpicos, n\u00e3o regras universais para sele\u00e7\u00e3o de carga.<\/p>\n\n\n\n<figure data-spectra-id=\"spectra-87dc4988-908d-42cf-997c-b0f8d029f5b6\" class=\"wp-block-image aligncenter size-full has-custom-border\" ><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/b-c-d-curve-options-comparison.png\" alt=\"Compara\u00e7\u00e3o conceitual das op\u00e7\u00f5es de MCB com curvas B, C e D\" class=\"wp-image-702\"  width=\"1672\" height=\"941\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/b-c-d-curve-options-comparison.png 1672w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/b-c-d-curve-options-comparison-600x338.png 600w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/b-c-d-curve-options-comparison-300x169.png 300w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/b-c-d-curve-options-comparison-1024x576.png 1024w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/b-c-d-curve-options-comparison-768x432.png 768w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/b-c-d-curve-options-comparison-1536x864.png 1536w\" sizes=\"auto, (max-width: 1672px) 100vw, 1672px\" \/><figcaption class=\"wp-element-caption\">Compara\u00e7\u00e3o conceitual das curvas B, C e D. A designa\u00e7\u00e3o da curva \u00e9 um dos par\u00e2metros de sele\u00e7\u00e3o, e a documenta\u00e7\u00e3o exata do modelo deve ser verificada.<\/figcaption><\/figure>\n\n\n\n<h2 id=\"mcb-trip-curve\" class=\"wp-block-heading\">O que \u00e9 uma curva de disparo de um disjuntor?<\/h2>\n\n\n<p class=\"wp-block-paragraph\">Um disjuntor de corrente nominal (MCB) protege um circuito contra condi\u00e7\u00f5es de sobrecorrente, mas a forma como ele responde depende de outros fatores al\u00e9m de sua capacidade nominal em amperes.<\/p>\n<p class=\"wp-block-paragraph\">Uma caracter\u00edstica da viagem descreve parte dessa resposta.<\/p>\n<p class=\"wp-block-paragraph\">No caso dos disjuntores de corrente residual (MCBs) das curvas B, C e D, uma das diferen\u00e7as mais evidentes \u00e9 a regi\u00e3o de disparo instant\u00e2neo ou magn\u00e9tico.<\/p>\n<p class=\"wp-block-paragraph\">Considere dois disjuntores com a mesma corrente nominal.<\/p>\n<p class=\"wp-block-paragraph\">Um disjuntor de curva B e um disjuntor de curva D podem ter a mesma corrente nominal em condi\u00e7\u00f5es normais, mas suas faixas de disparo instant\u00e2neo podem diferir substancialmente.<\/p>\n<p class=\"wp-block-paragraph\">\u00c9 por isso que:<\/p>\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p class=\"wp-block-paragraph\">\u201cAs designa\u00e7\u00f5es \u201dcurva B de 32 A\u201c e \u201dcurva D de 32 A\u201d n\u00e3o descrevem um comportamento de prote\u00e7\u00e3o id\u00eantico simplesmente porque ambos os disjuntores t\u00eam classifica\u00e7\u00e3o nominal de 32 A.<\/p><\/blockquote>\n\n\n<p class=\"wp-block-paragraph\">A curva \u00e9, portanto, mais um par\u00e2metro de sele\u00e7\u00e3o, juntamente com:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>corrente nominal<\/li>\n<li>tens\u00e3o<\/li>\n<li>postes<\/li>\n<li>capacidade de ruptura<\/li>\n<li>formato de montagem<\/li>\n<li>modelo exato<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Para obter mais informa\u00e7\u00f5es sobre o processo de sele\u00e7\u00e3o, consulte <a href=\"https:\/\/ritoks.com\/pt-br\/ac-mcb-selection-guide\/\">Guia de sele\u00e7\u00e3o de disjuntores de corrente alternada (MCB): corrente, p\u00f3los, curva de disparo e capacidade de interrup\u00e7\u00e3o<\/a>.<\/p>\n\n\n\n<h2 id=\"b-curve\" class=\"wp-block-heading\">O que \u00e9 um disjuntor de curva B?<\/h2>\n\n\n<p class=\"wp-block-paragraph\">Uma caracter\u00edstica B geralmente utiliza uma faixa de disparo instant\u00e2neo de aproximadamente 3 a 5 vezes a corrente nominal.<\/p>\n<p class=\"wp-block-paragraph\">Em termos gerais, isso significa que a regi\u00e3o magn\u00e9tica instant\u00e2nea \u00e9 atingida com um m\u00faltiplo da corrente nominal menor do que nas caracter\u00edsticas C ou D.<\/p>\n<p class=\"wp-block-paragraph\">As orienta\u00e7\u00f5es do fabricante geralmente recomendam o uso da classe B em aplica\u00e7\u00f5es nas quais se espera uma corrente de irrup\u00e7\u00e3o relativamente baixa.<\/p>\n<p class=\"wp-block-paragraph\">No entanto, isso n\u00e3o deve ser transformado em uma regra como:<\/p>\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p class=\"wp-block-paragraph\">\u201cTodos os circuitos de ilumina\u00e7\u00e3o devem utilizar a curva B.\u201d<\/p><\/blockquote>\n<p class=\"wp-block-paragraph\">A escolha efetiva depende do circuito, da corrente de irrup\u00e7\u00e3o prevista, das condi\u00e7\u00f5es de falha e dos requisitos de projeto aplic\u00e1veis.<\/p>\n\n\n<h3 class=\"wp-block-heading\">Disponibilidade atual da Curva B da RITOKS<\/h3>\n\n\n<p class=\"wp-block-paragraph\">Atualmente publicado <a href=\"https:\/\/ritoks.com\/pt-br\/product-category\/ac-power-protection\/\">Dados do disjuntor RITOKS AC MCB<\/a> confirma a disponibilidade da curva B em:<\/p>\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/ritoks.com\/pt-br\/products\/miniature-circuit-breaker-63a-10ka\/\">RTSXD01<\/a> \u2014 B \/ C \/ D<\/li>\n<li>RTSXD03 \u2014 B \/ C<\/li>\n<li><a href=\"https:\/\/ritoks.com\/pt-br\/products\/1pn-miniature-circuit-breaker-32a-6ka\/\">RTSXD02<\/a> \u2014 B \/ C<\/li>\n<li><a href=\"https:\/\/ritoks.com\/pt-br\/products\/miniature-circuit-breaker-63a-10ka-pro\/\">RTSXD04<\/a> \u2014 B \/ C \/ D<\/li>\n<li><a href=\"https:\/\/ritoks.com\/pt-br\/products\/m60-ac-miniature-circuit-breaker-6-63a\/\">RTS-ACM60<\/a> \u2014 B \/ C<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">A curva de viagem do RTS-AC47 ainda n\u00e3o foi confirmada.<\/p>\n<p class=\"wp-block-paragraph\">Essas informa\u00e7\u00f5es confirmam apenas a disponibilidade. Elas n\u00e3o definem o comportamento exato de corrente em fun\u00e7\u00e3o do tempo espec\u00edfico do modelo, al\u00e9m da designa\u00e7\u00e3o da curva publicada.<\/p>\n\n\n<h2 id=\"c-curve\" class=\"wp-block-heading\">O que \u00e9 um disjuntor de curva C?<\/h2>\n\n\n<p class=\"wp-block-paragraph\">Uma caracter\u00edstica C geralmente utiliza uma faixa de disparo instant\u00e2neo de aproximadamente 5 a 10 vezes a corrente nominal.<\/p>\n<p class=\"wp-block-paragraph\">Em compara\u00e7\u00e3o com a caracter\u00edstica B, isso permite um m\u00faltiplo de corrente de curta dura\u00e7\u00e3o mais elevado antes de entrar na regi\u00e3o de desligamento instant\u00e2neo.<\/p>\n<p class=\"wp-block-paragraph\">A Eaton descreve a caracter\u00edstica C como adequada para situa\u00e7\u00f5es com corrente de arranque m\u00e9dia e d\u00e1 exemplos que incluem pequenos transformadores, ilumina\u00e7\u00e3o, dispositivos de piloto, circuitos de controle e bobinas. Esse \u00e9 um contexto geral \u00fatil, mas isso n\u00e3o significa que todas essas aplica\u00e7\u00f5es exijam automaticamente a curva C.<\/p>\n\n\n<h3 class=\"wp-block-heading\">Disponibilidade atual da curva C da RITOKS<\/h3>\n\n<p class=\"wp-block-paragraph\">A curva C \u00e9, atualmente, a curva mais amplamente comprovada entre as fam\u00edlias de MCB do RITOKS AC publicadas:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>RTSXD01 \u2014 B \/ C \/ D<\/li>\n<li>RTSXD03 \u2014 B \/ C<\/li>\n<li>RTSXD02 \u2014 B \/ C<\/li>\n<li>RTSXD04 \u2014 B \/ C \/ D<\/li>\n<li>RTS-ACM60 \u2014 B \/ C<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">Mais uma vez, o RTS-AC47 n\u00e3o possui, no momento, nenhuma designa\u00e7\u00e3o de curva confirmada no site.<\/p>\n\n\n<h2 id=\"d-curve\" class=\"wp-block-heading\">O que \u00e9 um disjuntor de curva D?<\/h2>\n\n\n<p class=\"wp-block-paragraph\">Uma caracter\u00edstica D geralmente utiliza uma faixa de disparo instant\u00e2neo de aproximadamente 10 a 20 vezes a corrente nominal.<\/p>\n<p class=\"wp-block-paragraph\">Essa \u00e9 a mais alta das tr\u00eas regi\u00f5es instant\u00e2neas comuns discutidas aqui.<\/p>\n<p class=\"wp-block-paragraph\">As orienta\u00e7\u00f5es dos fabricantes costumam associar as caracter\u00edsticas D a equipamentos com maior corrente de irrup\u00e7\u00e3o. A Eaton cita motores, transformadores, fontes de alimenta\u00e7\u00e3o e outros sistemas altamente indutivos como exemplos t\u00edpicos.<\/p>\n<p class=\"wp-block-paragraph\">A palavra \u201ct\u00edpico\u201d \u00e9 importante.<\/p>\n<p class=\"wp-block-paragraph\">N\u00e3o seria seguro concluir que:<\/p>\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p class=\"wp-block-paragraph\">\u201cMotor = curva D.\u201d<\/p><\/blockquote>\n<p class=\"wp-block-paragraph\">Um circuito el\u00e9trico de motor pode envolver muitas vari\u00e1veis, incluindo caracter\u00edsticas de partida e o projeto mais amplo de prote\u00e7\u00e3o. A curva do disjuntor deve, portanto, ser selecionada com base em requisitos de engenharia comprovados, e n\u00e3o apenas com base no nome do equipamento.<\/p>\n\n\n<h3 class=\"wp-block-heading\">Disponibilidade atual da Curva D da RITOKS<\/h3>\n\n<p class=\"wp-block-paragraph\">Os dados atuais do RITOKS publicados confirmam a curva D em:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>RTSXD01<\/li>\n<li>RTSXD04<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">As outras fam\u00edlias de disjuntores AC MCB atualmente dispon\u00edveis no mercado n\u00e3o apresentam informa\u00e7\u00f5es confirmadas sobre a disponibilidade da curva D em suas p\u00e1ginas de produtos.<\/p>\n\n\n<h2 id=\"why-curves-differ\" class=\"wp-block-heading\">Por que as curvas utilizam regi\u00f5es instant\u00e2neas diferentes<\/h2>\n\n\n<p class=\"wp-block-paragraph\">Os equipamentos el\u00e9tricos podem consumir corrente acima de seu n\u00edvel de opera\u00e7\u00e3o normal por um curto per\u00edodo de tempo.<\/p>\n<p class=\"wp-block-paragraph\">Isso pode ocorrer durante eventos como a energiza\u00e7\u00e3o ou a inicializa\u00e7\u00e3o.<\/p>\n<p class=\"wp-block-paragraph\">Se a faixa de disparo instant\u00e2neo do disjuntor for muito baixa para a corrente de curta dura\u00e7\u00e3o esperada, o disjuntor poder\u00e1 disparar mesmo que o evento fa\u00e7a parte da inicializa\u00e7\u00e3o normal do equipamento.<\/p>\n<p class=\"wp-block-paragraph\">Por outro lado, o simples fato de escolher uma curva com uma regi\u00e3o instant\u00e2nea maior n\u00e3o significa, automaticamente, que ela seja melhor.<\/p>\n<p class=\"wp-block-paragraph\">O sistema de prote\u00e7\u00e3o ainda precisa responder adequadamente \u00e0s falhas reais.<\/p>\n<p class=\"wp-block-paragraph\">\u00c9 por isso que as caracter\u00edsticas B, C e D devem ser entendidas como diferentes caracter\u00edsticas de prote\u00e7\u00e3o, e n\u00e3o como classes de qualidade.<\/p>\n<p class=\"wp-block-paragraph\">D n\u00e3o \u00e9 uma vers\u00e3o \u201cpremium\u201d do C, e o C n\u00e3o \u00e9 uma \u201catualiza\u00e7\u00e3o\u201d do B.<\/p>\n\n\n<h2 id=\"same-rated-current\" class=\"wp-block-heading\">B x C x D com a mesma corrente nominal<\/h2>\n\n\n<p class=\"wp-block-paragraph\">Imagine tr\u00eas disjuntores que tenham todos a mesma corrente nominal, In.<\/p>\n<p class=\"wp-block-paragraph\">Utilizando os intervalos de caracter\u00edsticas comuns:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>B atinge sua regi\u00e3o instant\u00e2nea em torno de 3\u20135 \u00d7 In<\/li>\n<li>C cerca de 5\u201310 \u00d7 In<\/li>\n<li>D cerca de 10\u201320 \u00d7 In<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">A t\u00edtulo de ilustra\u00e7\u00e3o, se In = 10 A, esses m\u00faltiplos correspondem matematicamente a:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>B: aproximadamente 30\u201350 A<\/li>\n<li>C: aproximadamente 50\u2013100 A<\/li>\n<li>D: aproximadamente 100\u2013200 A<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">Este exemplo aritm\u00e9tico serve apenas para demonstrar o significado dos m\u00faltiplos. N\u00e3o se trata de uma recomenda\u00e7\u00e3o de sele\u00e7\u00e3o de produto e n\u00e3o deve ser interpretado como o comportamento operacional exato de um disjuntor RITOKS espec\u00edfico.<\/p>\n<p class=\"wp-block-paragraph\">O comportamento real do disjuntor deve ser verificado com base na documenta\u00e7\u00e3o exata do fabricante sobre tempo-corrente e nos requisitos aplic\u00e1veis ao produto.<\/p>\n\n\n<h2 id=\"curve-availability\" class=\"wp-block-heading\">Vis\u00e3o geral da disponibilidade atual da curva RITOKS<\/h2>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table><thead><tr><th>Modelo RITOKS<\/th><th>B<\/th><th>C<\/th><th>D<\/th><th>Evid\u00eancias atuais<\/th><\/tr><\/thead><tbody><tr><td>RTSXD01<\/td><td>Sim<\/td><td>Sim<\/td><td>Sim<\/td><td>Disponibilidade publicada<\/td><\/tr><tr><td>RTSXD03<\/td><td>Sim<\/td><td>Sim<\/td><td>\u2014<\/td><td>Disponibilidade publicada<\/td><\/tr><tr><td>RTSXD02<\/td><td>Sim<\/td><td>Sim<\/td><td>\u2014<\/td><td>Disponibilidade publicada<\/td><\/tr><tr><td>RTSXD04<\/td><td>Sim<\/td><td>Sim<\/td><td>Sim<\/td><td>Disponibilidade publicada<\/td><\/tr><tr><td>RTS-ACM60<\/td><td>Sim<\/td><td>Sim<\/td><td>\u2014<\/td><td>Disponibilidade publicada<\/td><\/tr><tr><td>RTS-AC47<\/td><td>N\u00e3o confirmado<\/td><td>N\u00e3o confirmado<\/td><td>N\u00e3o confirmado<\/td><td>Curva n\u00e3o confirmada<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n<p class=\"wp-block-paragraph\">Esta tabela deve ser utilizada exclusivamente para a pr\u00e9-sele\u00e7\u00e3o de fam\u00edlias de produtos.<\/p>\n<p class=\"wp-block-paragraph\">Isso n\u00e3o significa que as curvas do fabricante externo citadas anteriormente sejam exatamente as curvas tempo-corrente testadas desses modelos da RITOKS.<\/p>\n\n\n<figure data-spectra-id=\"spectra-0e259182-1e05-4734-a709-37163a7d2de6\" class=\"wp-block-image aligncenter size-full has-custom-border\" ><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-pole-formats-panel.png\" alt=\"Diferentes formatos de p\u00f3los de disjuntores miniatura CA em um painel de distribui\u00e7\u00e3o industrial\" class=\"wp-image-703\"  width=\"1672\" height=\"941\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-pole-formats-panel.png 1672w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-pole-formats-panel-600x338.png 600w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-pole-formats-panel-300x169.png 300w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-pole-formats-panel-1024x576.png 1024w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-pole-formats-panel-768x432.png 768w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-pole-formats-panel-1536x864.png 1536w\" sizes=\"auto, (max-width: 1672px) 100vw, 1672px\" \/><figcaption class=\"wp-element-caption\">Formatos ilustrativos de produtos MCB CA; a disponibilidade das curvas e os par\u00e2metros el\u00e9tricos devem ser confirmados para o modelo espec\u00edfico.<\/figcaption><\/figure>\n\n\n\n<h2 id=\"selection-process\" class=\"wp-block-heading\">Como escolher entre as op\u00e7\u00f5es de curvas B, C e D<\/h2>\n\n\n<p class=\"wp-block-paragraph\">O processo pr\u00e1tico de sele\u00e7\u00e3o de fornecedores come\u00e7a com a caracter\u00edstica exigida, e n\u00e3o com uma suposi\u00e7\u00e3o baseada no nome do produto.<\/p>\n\n<h3 class=\"wp-block-heading\">1. Confirmar os requisitos de carga e corrente de irrup\u00e7\u00e3o<\/h3>\n<p class=\"wp-block-paragraph\">Verifique se a documenta\u00e7\u00e3o do projeto j\u00e1 define:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>corrente de partida prevista<\/li>\n<li>comportamento de corrente de irrup\u00e7\u00e3o<\/li>\n<li>curva exigida<\/li>\n<li>outras restri\u00e7\u00f5es de prote\u00e7\u00e3o<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">Se a curva necess\u00e1ria j\u00e1 tiver sido especificada, use-a como ponto de partida.<\/p>\n\n<h3 class=\"wp-block-heading\">2. Confirme a corrente nominal<\/h3>\n<p class=\"wp-block-paragraph\">A curva de disparo e a corrente nominal s\u00e3o par\u00e2metros distintos.<\/p>\n<p class=\"wp-block-paragraph\">Por exemplo:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>C16<\/li>\n<li>C32<\/li>\n<li>C63<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">Todos t\u00eam a designa\u00e7\u00e3o \u201cC\u201d, mas apresentam intensidades nominais diferentes.<\/p>\n<p class=\"wp-block-paragraph\">N\u00e3o selecione a curva primeiro e ignore a corrente nominal do disjuntor.<\/p>\n\n<h3 class=\"wp-block-heading\">3. Confirme a capacidade de frenagem<\/h3>\n<p class=\"wp-block-paragraph\">Curva de deslocamento e <a href=\"https:\/\/ritoks.com\/pt-br\/6ka-vs-10ka-mcb-breaking-capacity\/\">Capacidade de interrup\u00e7\u00e3o de MCBs de 6 kA vs. 10 kA<\/a> tamb\u00e9m s\u00e3o par\u00e2metros diferentes.<\/p>\n<p class=\"wp-block-paragraph\">A designa\u00e7\u00e3o A, B, C ou D n\u00e3o indica se o disjuntor possui:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>6 kA<\/li>\n<li>10 kA<\/li>\n<li>ou outro valor de capacidade de ruptura<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">Essa caracter\u00edstica deve ser verificada separadamente no produto espec\u00edfico.<\/p>\n\n<h3 class=\"wp-block-heading\">4. Confirme a configura\u00e7\u00e3o dos p\u00f3los<\/h3>\n<p class=\"wp-block-paragraph\">Uma curva B\/C\/D exigida s\u00f3 pode ser \u00fatil se a mesma fam\u00edlia de produtos tamb\u00e9m oferecer o seguinte:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>1P<\/li>\n<li>1P+N<\/li>\n<li>2P<\/li>\n<li>3P<\/li>\n<li>3P+N<\/li>\n<li>4P<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">configura\u00e7\u00e3o.<\/p>\n\n<h3 class=\"wp-block-heading\">5. Verifique a documenta\u00e7\u00e3o exata do produto<\/h3>\n<p class=\"wp-block-paragraph\">A etapa final consiste em verificar o pr\u00f3prio disjuntor selecionado.<\/p>\n<p class=\"wp-block-paragraph\">N\u00e3o presuma que:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>todas as curvas B se comportam da mesma forma em todos os fabricantes<\/li>\n<li>todas as curvas C apresentam toler\u00e2ncias de tempo-corrente id\u00eanticas<\/li>\n<li>toda curva D \u00e9 adequada para qualquer carga com pico de corrente de entrada elevado<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">A designa\u00e7\u00e3o da curva \u00e9 uma parte da especifica\u00e7\u00e3o completa do produto.<\/p>\n\n\n<h2 id=\"common-mistakes\" class=\"wp-block-heading\">Erros comuns na sele\u00e7\u00e3o das curvas B\/C\/D<\/h2>\n\n\n<h3 class=\"wp-block-heading\">Considerando B, C e D como n\u00edveis de qualidade<\/h3>\n<p class=\"wp-block-paragraph\">S\u00e3o caracter\u00edsticas diferentes das viagens, e n\u00e3o \u201cb\u00e1sicas\u201d, \u201cmelhores\u201d e \u201cas melhores\u201d.\u201d<\/p>\n\n<h3 class=\"wp-block-heading\">Sele\u00e7\u00e3o apenas com base no nome do carregamento<\/h3>\n<p class=\"wp-block-paragraph\">Afirma\u00e7\u00f5es como \u201cmotor significa curva D\u201d s\u00e3o muito gen\u00e9ricas.<\/p>\n<p class=\"wp-block-paragraph\">\u00c9 preciso levar em conta a corrente de irrup\u00e7\u00e3o esperada e o projeto el\u00e9trico efetivo.<\/p>\n\n<h3 class=\"wp-block-heading\">Ignorando a corrente nominal<\/h3>\n<p class=\"wp-block-paragraph\">Uma curva correta combinada com a classifica\u00e7\u00e3o de corrente incorreta n\u00e3o constitui uma sele\u00e7\u00e3o correta do disjuntor.<\/p>\n\n<h3 class=\"wp-block-heading\">Ignorando a capacidade de ruptura<\/h3>\n<p class=\"wp-block-paragraph\">A caracter\u00edstica B\/C\/D e a capacidade de frenagem s\u00e3o par\u00e2metros distintos.<\/p>\n\n<h3 class=\"wp-block-heading\">Supondo que os dados da curva externa se apliquem automaticamente a todos os modelos RITOKS<\/h3>\n<p class=\"wp-block-paragraph\">Os valores 3\u20135 \u00d7 In, 5\u201310 \u00d7 In e 10\u201320 \u00d7 In utilizados neste guia representam intervalos de caracter\u00edsticas gerais, respaldados pela literatura t\u00e9cnica oficial dos fabricantes. As p\u00e1ginas de produtos da RITOKS confirmam, atualmente, quais letras de curva est\u00e3o dispon\u00edveis, mas n\u00e3o publicam as curvas tempo-corrente completas espec\u00edficas para cada modelo.<\/p>\n\n<h3 class=\"wp-block-heading\">Como criar um gr\u00e1fico de curva sem dados do modelo<\/h3>\n<p class=\"wp-block-paragraph\">Um gr\u00e1fico com apar\u00eancia realista pode sugerir um n\u00edvel de precis\u00e3o maior do que o comprovado pelas evid\u00eancias dispon\u00edveis.<\/p>\n<p class=\"wp-block-paragraph\">At\u00e9 que esteja dispon\u00edvel documenta\u00e7\u00e3o precisa sobre tempo-corrente espec\u00edfica do modelo RITOKS, a sele\u00e7\u00e3o da curva deve basear-se na designa\u00e7\u00e3o publicada e nos requisitos do projeto, e n\u00e3o em um gr\u00e1fico elaborado.<\/p>\n\n\n<h2 id=\"request-technical-data\" class=\"wp-block-heading\">Quando voc\u00ea deve solicitar mais dados t\u00e9cnicos?<\/h2>\n\n\n<p class=\"wp-block-paragraph\">No caso de uma consulta de fornecimento de rotina, saber a designa\u00e7\u00e3o da curva exigida pode ser suficiente para selecionar os modelos dispon\u00edveis.<\/p>\n<p class=\"wp-block-paragraph\">Para uma an\u00e1lise t\u00e9cnica mais detalhada, os compradores podem precisar de documenta\u00e7\u00e3o adicional, como:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>caracter\u00edstica tempo-corrente exata<\/li>\n<li>toler\u00e2ncia ao disparo instant\u00e2neo<\/li>\n<li>dados sobre capacidade m\u00e1xima<\/li>\n<li>norma aplic\u00e1vel ao produto<\/li>\n<li>informa\u00e7\u00f5es de coordena\u00e7\u00e3o, quando necess\u00e1rio<\/li>\n<li>documentos de teste ou certifica\u00e7\u00e3o espec\u00edficos para cada modelo<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">Esses requisitos devem ser solicitados especificamente para o produto em quest\u00e3o, em vez de serem presumidos com base apenas nas letras B, C ou D.<\/p>\n\n\n<h2 id=\"frequently-asked-questions\" class=\"wp-block-heading\">Perguntas frequentes<\/h2>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Qual \u00e9 a principal diferen\u00e7a entre os disjuntores de corrente nominal (MCBs) das curvas B, C e D?<\/summary>\n<p class=\"wp-block-paragraph\">A principal diferen\u00e7a discutida aqui \u00e9 a regi\u00e3o de disparo instant\u00e2neo. A documenta\u00e7\u00e3o comum dos fabricantes utiliza valores aproximados de 3\u20135 \u00d7 In para B, 5\u201310 \u00d7 In para C e 10\u201320 \u00d7 In para D.<\/p>\n<\/details>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>A curva C \u00e9 melhor do que a curva B?<\/summary>\n<p class=\"wp-block-paragraph\">N\u00e3o. S\u00e3o caracter\u00edsticas de disparo diferentes. A escolha adequada depende do circuito e das condi\u00e7\u00f5es de corrente de irrup\u00e7\u00e3o previstas.<\/p>\n<\/details>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>A curva D \u00e9 sempre utilizada em motores?<\/summary>\n<p class=\"wp-block-paragraph\">N\u00e3o. A curva D \u00e9 comumente associada a aplica\u00e7\u00f5es com maior corrente de irrup\u00e7\u00e3o, e as orienta\u00e7\u00f5es dos fabricantes costumam citar motores e transformadores como exemplos, mas a curva correta depende do equipamento espec\u00edfico e do projeto de prote\u00e7\u00e3o.<\/p>\n<\/details>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>A RITOKS oferece disjuntores de corrente residual (MCBs) com curvas B, C e D?<\/summary>\n<p class=\"wp-block-paragraph\">Sim, em determinadas fam\u00edlias de produtos. Os modelos RTSXD01 e RTSXD04 apresentam, atualmente, as op\u00e7\u00f5es B\/C\/D. Os modelos RTSXD02, RTSXD03 e RTS-ACM60 apresentam as op\u00e7\u00f5es B\/C. O modelo RTS-AC47 n\u00e3o possui, no momento, uma designa\u00e7\u00e3o de curva confirmada.<\/p>\n<\/details>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>A letra \u201cCurve\u201d indica a capacidade de ruptura?<\/summary>\n<p class=\"wp-block-paragraph\">N\u00e3o. A caracter\u00edstica de deslocamento e a capacidade de frenagem s\u00e3o par\u00e2metros distintos do produto e ambos devem ser verificados.<\/p>\n<\/details>\n\n\n\n<div class=\"wp-block-group has-ast-global-color-5-color has-ast-global-color-2-background-color has-text-color has-background is-layout-constrained wp-container-core-group-is-layout-737f6912 wp-block-group-is-layout-constrained\" style=\"border-radius:6px;margin-top:48px;padding-top:40px;padding-right:32px;padding-bottom:40px;padding-left:32px\">\n\n\n<h2 class=\"wp-block-heading\">Precisa de ajuda para escolher uma curva de disparo para um disjuntor?<\/h2>\n\n\n<p class=\"wp-block-paragraph\">A RITOKS oferece fam\u00edlias de disjuntores miniatura de corrente alternada com diferentes valores nominais de corrente, configura\u00e7\u00f5es de p\u00f3los, capacidades de interrup\u00e7\u00e3o e disponibilidade das curvas B\/C\/D.<\/p>\n<p class=\"wp-block-paragraph\">Use um <a href=\"https:\/\/ritoks.com\/pt-br\/ac-mcb-rfq-checklist\/\">Lista de verifica\u00e7\u00e3o para solicita\u00e7\u00e3o de cota\u00e7\u00e3o (RFQ) de disjuntores de corrente alternada (AC) e disjuntores magn\u00e9ticos (MCB)<\/a> fornecer:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>Tens\u00e3o CA<\/li>\n<li>corrente necess\u00e1ria<\/li>\n<li>configura\u00e7\u00e3o dos p\u00f3los<\/li>\n<li>curva de deslocamento exigida<\/li>\n<li>capacidade de frenagem necess\u00e1ria<\/li>\n<li>quantidade<\/li>\n<li>aplicativo<\/li>\n<li>qualquer documenta\u00e7\u00e3o t\u00e9cnica necess\u00e1ria<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">A RITOKS pode, ent\u00e3o, comparar a consulta com as fam\u00edlias de produtos atualmente publicadas e com os dados confirmados dos modelos.<\/p>\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-ast-global-color-0-background-color has-background wp-element-button\" href=\"https:\/\/ritoks.com\/pt-br\/product-category\/ac-power-protection\/miniature-circuit-breakers\/\">Ver disjuntores miniatura CA \u2192<\/a><\/div>\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-ast-global-color-0-background-color has-background wp-element-button\" href=\"https:\/\/ritoks.com\/pt-br\/ac-mcb-selection-guide\/\">Leia o Guia de Sele\u00e7\u00e3o de Disjuntores de CA \u2192<\/a><\/div>\n<div class=\"wp-block-button is-style-outline is-style-outline--1\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/ritoks.com\/pt-br\/contact-us\/\">Entre em contato com a RITOKS \u2192 Solicite um or\u00e7amento<\/a><\/div>\n<\/div>\n\n\n<\/div>\n\n\n<\/div>","protected":false},"excerpt":{"rendered":"<p>B Curve vs C Curve vs D Curve MCBs: What\u2019s the Difference? B, C and D curves are different tripping [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"no-sidebar","site-content-layout":"page-builder","ast-site-content-layout":"full-width-container","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"disabled","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"disabled","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ritoks_resource_detail_renderer":null,"ritoks_resource_product_cat_term_id":0,"footnotes":""},"categories":[64],"tags":[],"class_list":["post-699","post","type-post","status-publish","format-standard","hentry","category-circuit-protection"],"acf":[],"spectra_blocks_featured_image_url":null,"spectra_blocks_author_info":{"display_name":"RITOKS","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/6d7d0fc73468198f994ab13ef6eb6558c53b6ed1ad86364d5165efe8bdf8eb4a?s=96&d=mm&r=g","author_link":"https:\/\/ritoks.com\/pt-br\/author\/dazzlingwqbgmail-com\/","description":""},"_links":{"self":[{"href":"https:\/\/ritoks.com\/pt-br\/wp-json\/wp\/v2\/posts\/699","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ritoks.com\/pt-br\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ritoks.com\/pt-br\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ritoks.com\/pt-br\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/ritoks.com\/pt-br\/wp-json\/wp\/v2\/comments?post=699"}],"version-history":[{"count":4,"href":"https:\/\/ritoks.com\/pt-br\/wp-json\/wp\/v2\/posts\/699\/revisions"}],"predecessor-version":[{"id":731,"href":"https:\/\/ritoks.com\/pt-br\/wp-json\/wp\/v2\/posts\/699\/revisions\/731"}],"wp:attachment":[{"href":"https:\/\/ritoks.com\/pt-br\/wp-json\/wp\/v2\/media?parent=699"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ritoks.com\/pt-br\/wp-json\/wp\/v2\/categories?post=699"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ritoks.com\/pt-br\/wp-json\/wp\/v2\/tags?post=699"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}