{"id":2018,"date":"2026-10-03T00:43:16","date_gmt":"2026-10-03T00:43:16","guid":{"rendered":"http:\/\/ritoks.com\/"},"modified":"2026-10-05T14:45:17","modified_gmt":"2026-10-05T14:45:17","slug":"power-module-heatsink-selection-guide","status":"publish","type":"post","link":"https:\/\/ritoks.com\/ro\/power-module-heatsink-selection-guide\/","title":{"rendered":"Power Module Heatsink Selection Guide: Loss, Thermal Resistance and Airflow"},"content":{"rendered":"<p class=\"wp-block-paragraph\">A power-module heatsink is selected from a thermal path, not from module current alone. The designer needs semiconductor loss at the real duty, an allowed junction-temperature objective, interface data, heatsink performance under the installed airflow and a mechanical arrangement that preserves contact. Missing any link can make an apparently generous extrusion inadequate.<\/p>\n\n\n<p class=\"wp-block-paragraph\">This guide explains the evidence chain required to select a heatsink for SCR, rectifier or other power modules. It does not calculate a heatsink for an unknown semiconductor, publish transferable thermal-resistance values or approve a mounting method without exact device and heatsink documents.<\/p>\n\n\n<h2 class=\"wp-block-heading\">Prezentare general\u0103 a datelor de intrare pentru luarea deciziilor<\/h2>\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Date de intrare pentru luarea deciziilor<\/th><th>Cump\u0103r\u0103torul trebuie s\u0103 confirme<\/th><th>Documente necesare<\/th><\/tr><\/thead><tbody><tr><td>Heat generation<\/td><td>Conduction and switching loss at the design duty<\/td><td>Exact semiconductor loss data or validated calculation<\/td><\/tr><tr><td>Limita de temperatur\u0103<\/td><td>Maximum junction objective and worst local ambient<\/td><td>Device limits and project criterion<\/td><\/tr><tr><td>Interface path<\/td><td>Case, thermal interface material and contact condition<\/td><td>Mounting instruction and interface data<\/td><\/tr><tr><td>Heatsink performance<\/td><td>Thermal behavior at actual orientation and airflow<\/td><td>Exact heatsink curve or validated model<\/td><\/tr><tr><td>Potrivire mecanic\u0103<\/td><td>Footprint, hole pattern, flatness, fasteners and clearance<\/td><td>Desen de asamblare cotat<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n<figure data-spectra-id=\"spectra-5d2a70be-6893-4eaa-b1d4-7e3e6517b56d\" class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" height=\"1050\" width=\"1400\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/power-module-heatsink-selection-guide-body-01.webp\" alt=\"Power Module Heatsink application inputs diagram\" class=\"wp-image-2016\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/power-module-heatsink-selection-guide-body-01.webp 1400w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/power-module-heatsink-selection-guide-body-01-300x225.webp 300w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/power-module-heatsink-selection-guide-body-01-1024x768.webp 1024w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/power-module-heatsink-selection-guide-body-01-768x576.webp 768w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/power-module-heatsink-selection-guide-body-01-16x12.webp 16w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/power-module-heatsink-selection-guide-body-01-600x450.webp 600w\" sizes=\"auto, (max-width: 1400px) 100vw, 1400px\" \/><figcaption class=\"wp-element-caption\">Map the application before comparing an exact Power Module Heatsink candidate.<\/figcaption><\/figure>\n\n\n<h2 class=\"wp-block-heading\">Begin With Semiconductor Loss<\/h2>\n\n\n<p class=\"wp-block-paragraph\">Current rating is not a direct heat value. Determine conduction, switching and other relevant losses using the exact device characteristics and the actual waveform, duty and control method.<\/p>\n\n\n<p class=\"wp-block-paragraph\">Document who owns the loss calculation and preserve its inputs. If the semiconductor or duty changes, the heatsink review must be reopened instead of retaining the old result by default.<\/p>\n\n\n<h2 class=\"wp-block-heading\">Build the Complete Thermal Resistance Chain<\/h2>\n\n\n<p class=\"wp-block-paragraph\">The path normally includes junction-to-case behavior, the interface between module and sink, the heatsink itself and the air or other cooling medium. Each part has its own conditions and uncertainty.<\/p>\n\n\n<p class=\"wp-block-paragraph\">Do not subtract catalog temperatures without checking definitions. Use one consistent thermal model and units, and distinguish manufacturer limits from the project\u2019s chosen design margin.<\/p>\n\n\n<h2 class=\"wp-block-heading\">Treat Interface Quality as an Engineering Input<\/h2>\n\n\n<p class=\"wp-block-paragraph\">Flatness, surface condition, thermal interface material, application method, mounting force and tightening sequence influence contact performance. Follow the semiconductor and heatsink instructions that apply to the exact assembly.<\/p>\n\n\n<p class=\"wp-block-paragraph\">Adding more interface material is not automatically safer because excess thickness can increase resistance. The approved material and process should be repeatable in production and service.<\/p>\n\n\n<h2 class=\"wp-block-heading\">Use Heatsink Data for the Installed Airflow<\/h2>\n\n\n<p class=\"wp-block-paragraph\">Natural-convection performance depends on orientation, fin spacing and surrounding clearance. Forced-air performance depends on flow distribution, pressure capability, obstructions and where air temperature is measured.<\/p>\n\n\n<p class=\"wp-block-paragraph\">A fan free-air value is not the airflow through a loaded heatsink channel. Evaluate the complete path and use performance evidence whose test arrangement is relevant to the proposed installation.<\/p>\n\n\n<h2 class=\"wp-block-heading\">Verify Mechanical Compatibility<\/h2>\n\n\n<p class=\"wp-block-paragraph\">Check module footprint, mounting holes, terminal access, creepage and clearance needs, base thickness and available fastener depth. The electrical layout must not force a poor thermal contact or block fins.<\/p>\n\n\n<p class=\"wp-block-paragraph\">Create an assembly drawing that identifies the module, sink, interface, fasteners and orientation. This prevents the quotation from mixing compatible-looking parts that have not been reviewed together.<\/p>\n\n\n<h2 class=\"wp-block-heading\">Plan Verification and Field Maintenance<\/h2>\n\n\n<p class=\"wp-block-paragraph\">Prototype or thermal testing may be needed when calculations contain uncertain inputs, unusual duty or restricted airflow. Define sensor locations and acceptance criteria before the test.<\/p>\n\n\n<p class=\"wp-block-paragraph\">Dust, fan degradation and blocked clearances can raise temperature over time. The maintenance plan should preserve the airflow and inspection access assumed by the selection.<\/p>\n\n\n<h2 class=\"wp-block-heading\">Crearea unui dosar de probe bazat pe un model exact<\/h2>\n\n\n<p class=\"wp-block-paragraph\">Build the heatsink approval record around the exact module, mounting interface, available space and cooling arrangement. Match the proposed heatsink to its dimensioned drawing and the relevant thermal evidence under stated test or operating conditions. Record the mounting and airflow assumptions alongside the document revision. A compatible footprint or a product-family page cannot establish the thermal performance of the complete assembly.<\/p>\n\n\n<p class=\"wp-block-paragraph\">Verifica\u021bi dac\u0103 fiecare specifica\u021bie acceptat\u0103 descrie acela\u0219i articol care poate fi comandat. Carcasele similare pot con\u021bine circuite, terminale, materiale, firmware sau accesorii diferite. Nu combina\u021bi o cantitate maxim\u0103 dintr-o variant\u0103, un desen dintr-o alt\u0103 variant\u0103 \u0219i o caracteristic\u0103 dintr-o a treia variant\u0103. Marca\u021bi \u00een mod explicit c\u00e2mpurile nerezolvate, astfel \u00eenc\u00e2t acestea s\u0103 r\u0103m\u00e2n\u0103 vizibile pe parcursul procesului de revizuire tehnic\u0103 \u0219i comercial\u0103.<\/p>\n\n\n<h2 class=\"wp-block-heading\">P\u0103stra\u021bi datele de intrare ale proiectului separate de dovezile referitoare la produs<\/h2>\n\n\n<p class=\"wp-block-paragraph\">The project team defines the application: source, load, duty, environment, controls, mechanical limits and required functions. The supplier identifies an exact Power Module Heatsink and supports it with exact documents. Neither side should fill a gap by inference from appearance, a shared family name or one matching headline value.<\/p>\n\n\n<p class=\"wp-block-paragraph\">Bloca\u021bi dosarul cererii pe durata compar\u0103rii ofertelor. Dac\u0103 se modific\u0103 circuitul, sarcina, regimul de func\u021bionare, mediul, carcasa, metoda de r\u0103cire sau puterea necesar\u0103, emite\u021bi un dosar revizuit \u0219i solicita\u021bi fiec\u0103rui furnizor s\u0103 reconfirme produsul propus. \u00cen caz contrar, ofertele aparent comparabile ar putea r\u0103spunde unor cerin\u021be tehnice diferite.<\/p>\n\n\n<h2 class=\"wp-block-heading\">Gre\u0219eli frecvente \u00een domeniul achizi\u021biilor publice<\/h2>\n\n\n<ul class=\"wp-block-list\"><li>Selecting Power Module Heatsink from one headline rating while the application context remains incomplete.<\/li><li>Utilizarea unui circuit, a unei curbe, a unui schem\u0103 a bornelor sau a unei specifica\u021bii de performan\u021b\u0103 preluate de la un model similar.<\/li><li>Tratarea unei pagini de familie sau a unei fotografii de produs ca pe o prob\u0103 tehnic\u0103 incontestabil\u0103.<\/li><li>\u00cen cazul \u00een care se constat\u0103 c\u0103 un accesoriu, o func\u021bie a sistemului sau un rezultat al coordon\u0103rii este inclus f\u0103r\u0103 documenta\u021bie.<\/li><li>Aprobarea unui \u00eenlocuitor f\u0103r\u0103 a repeta verificarea aspectelor electrice, termice, mecanice \u0219i a probelor.<\/li><\/ul>\n\n\n<p class=\"wp-block-paragraph\">Remedia\u021bi aceste lacune \u00eenainte de a compara pre\u021bul \u0219i termenul de livrare. Persoana care efectueaz\u0103 revizuirea trebuie s\u0103 poat\u0103 urm\u0103ri fiecare afirma\u021bie acceptat\u0103, fie p\u00e2n\u0103 la cerin\u021bele proiectului, fie p\u00e2n\u0103 la documentul candidat corespunz\u0103tor. O ofert\u0103 poate r\u0103m\u00e2ne interesant\u0103 din punct de vedere comercial chiar dac\u0103 este incomplet\u0103 din punct de vedere tehnic, dar dovezile lips\u0103 nu trebuie s\u0103 dispar\u0103 din cuprinsul ofertei.<\/p>\n\n\n<h2 class=\"wp-block-heading\">Cum s\u0103 compara\u021bi ofertele furnizorilor<\/h2>\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Punct de compara\u021bie<\/th><th>Dovezi necesare<\/th><th>Nu accepta\u021bi<\/th><\/tr><\/thead><tbody><tr><td>Identitate exact\u0103<\/td><td>Codul complet pentru comand\u0103 \u0219i descrierea variantei<\/td><td>Doar numele de familie<\/td><\/tr><tr><td>Potrivire \u00eentre aplica\u021bii<\/td><td>R\u0103spunsul privind elementele proiectului blocate<\/td><td>Declara\u021bie generic\u0103 privind adecvarea<\/td><\/tr><tr><td>Dovezi tehnice<\/td><td>Documente actuale cu model exact \u0219i num\u0103r de revizie<\/td><td>Captur\u0103 de ecran sau pagina modelului \u00eenvecinat<\/td><\/tr><tr><td>Obiectul livr\u0103rii<\/td><td>Accesorii, interfe\u021be \u0219i documente incluse<\/td><td>\u201cPachet standard\u201d nedefinit\u201d<\/td><\/tr><tr><td>\u00centreb\u0103ri deschise<\/td><td>Lista abaterilor vizibile \u0219i a clarific\u0103rilor<\/td><td>T\u0103cerea este considerat\u0103 acceptare<\/td><\/tr><tr><td>\u00cenlocuire<\/td><td>O nou\u0103 analiz\u0103 care contravine tuturor cerin\u021belor<\/td><td>\u201cEchivalent\u201d din punct de vedere al aspectului<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n<figure data-spectra-id=\"spectra-8bed469a-9b81-48de-a02d-322bfb78a957\" class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" height=\"1050\" width=\"1400\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/power-module-heatsink-selection-guide-body-02.webp\" alt=\"Power Module Heatsink exact-model evidence chain diagram\" class=\"wp-image-2017\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/power-module-heatsink-selection-guide-body-02.webp 1400w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/power-module-heatsink-selection-guide-body-02-300x225.webp 300w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/power-module-heatsink-selection-guide-body-02-1024x768.webp 1024w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/power-module-heatsink-selection-guide-body-02-768x576.webp 768w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/power-module-heatsink-selection-guide-body-02-16x12.webp 16w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/power-module-heatsink-selection-guide-body-02-600x450.webp 600w\" sizes=\"auto, (max-width: 1400px) 100vw, 1400px\" \/><figcaption class=\"wp-element-caption\">Keep the Power Module Heatsink evidence chain attached to one exact order code.<\/figcaption><\/figure>\n\n\n<p class=\"wp-block-paragraph\">Normalize every Power Module Heatsink offer to the same application record. Keep document revisions, test conditions, included accessories and open questions beside each value. This makes differences in delivered scope visible and prevents a lower-cost but narrower offer from appearing equivalent to a complete solution.<\/p>\n\n\n<h2 class=\"wp-block-heading\">Fluxul de lucru pentru luarea deciziilor<\/h2>\n\n\n<ul class=\"wp-block-list\"><li>Stabilirea definitiv\u0103 a arhitecturii aplica\u021biei \u0219i a scenariului de func\u021bionare.<\/li><li>\u00cenregistra\u021bi constr\u00e2ngerile de mediu, termice \u0219i mecanice.<\/li><li>Identify the required Power Module Heatsink function without assuming a model.<\/li><li>Solicita\u021bi un cod complet al comenzii \u0219i documentele justificative exacte.<\/li><li>Compara\u021bi fiecare clauz\u0103 cu condi\u021biile \u0219i defini\u021biile aferente.<\/li><li>Solu\u021biona\u021bi abaterile \u0219i problemele legate de coordonare \u00eenainte de aprobarea comercial\u0103.<\/li><li>Arhiva\u021bi probele acceptate \u00eempreun\u0103 cu lista final\u0103 de materiale.<\/li><\/ul>\n\n\n<p class=\"wp-block-paragraph\">Opri\u021bi procesul de revizuire atunci c\u00e2nd o intrare critic\u0103 a aplica\u021biei este necunoscut\u0103, modelul men\u021bionat este ambiguu, o specifica\u021bie obligatorie este sus\u021binut\u0103 doar de un alt produc\u0103tor sau de un alt cod de comand\u0103, sau c\u00e2nd instalarea nu se \u00eencadreaz\u0103 \u00een dovezile disponibile. Acestea sunt lacune tehnice, nu detalii editoriale.<\/p>\n\n\n<h2 class=\"wp-block-heading\">Lista de verificare pentru preg\u0103tirea cererii de ofert\u0103<\/h2>\n\n\n<p class=\"wp-block-paragraph\">A useful RFQ for power module heatsink selection guide is concise enough to answer and complete enough to prevent silent assumptions. Identify unknown values as questions and require a full orderable code rather than a generic family recommendation.<\/p>\n\n\n<ul class=\"wp-block-list\"><li>Device loss<\/li><li>Interfa\u021b\u0103<\/li><li>Sink path<\/li><li>Calea de curgere a aerului<\/li><li>Ambient<\/li><li>Module footprint<\/li><li>Flatness<\/li><li>Fixare<\/li><li>Orientation<\/li><li>Service clearance<\/li><li>Cantitatea, destina\u021bia \u0219i limba \u00een care trebuie s\u0103 fie \u00eentocmite documentele<\/li><\/ul>\n\n\n<p class=\"wp-block-paragraph\">Solicita\u021bi versiunea actual\u0103 a fi\u0219ei tehnice \u0219i domeniul exact de aplicare al oric\u0103rei declara\u021bii privind certificarea, compatibilitatea, coordonarea sau performan\u021ba. Consemna\u021bi cantitatea \u0219i destina\u021bia dup\u0103 datele tehnice, astfel \u00eenc\u00e2t condi\u021biile comerciale s\u0103 nu ascund\u0103 aspectele tehnice nerezolvate.<\/p>\n\n\n<h2 class=\"wp-block-heading\">Predarea de la departamentul de inginerie c\u0103tre departamentul de achizi\u021bii<\/h2>\n\n\n<p class=\"wp-block-paragraph\">Engineering approval should identify the exact Power Module Heatsink code, accepted document revisions, unresolved deviations and the application record used for the decision. Purchasing can then compare commercial offers without silently changing the technical basis. If a supplier proposes another code, different accessory or revised configuration, route it back through the same review instead of treating it as an administrative substitution.<\/p>\n\n\n<p class=\"wp-block-paragraph\">P\u0103stra\u021bi dovezile aprobate \u00eempreun\u0103 cu comanda de achizi\u021bie \u0219i lista final\u0103 de materiale. Echipele responsabile cu recep\u021bia \u0219i produc\u021bia trebuie s\u0103 dispun\u0103 de informa\u021bii suficiente pentru a identifica articolul acceptat \u0219i pentru a opri procesul \u00een cazul \u00een care etichetarea, dispunerea terminalelor, accesoriile sau documenta\u021bia difer\u0103. Aceast\u0103 predare ofer\u0103, de asemenea, echipelor de \u00eentre\u021binere un punct de plecare trasabil pentru deciziile privind \u00eenlocuirea, \u00een loc s\u0103 se bazeze pe o fotografie, pe descrierea unei facturi vechi sau pe o singur\u0103 specifica\u021bie tehnic\u0103.<\/p>\n\n\n<h2 class=\"wp-block-heading\">\u00centreb\u0103ri frecvente<\/h2>\n\n\n<h3 class=\"wp-block-heading\">Can a heatsink be selected from module current rating?<\/h3>\n\n\n<p class=\"wp-block-paragraph\">No. Use semiconductor loss at the actual duty and the full thermal path.<\/p>\n\n\n<h3 class=\"wp-block-heading\">Is a lower catalog thermal resistance always better?<\/h3>\n\n\n<p class=\"wp-block-paragraph\">Only when the definition and test conditions apply to the installed orientation and airflow.<\/p>\n\n\n<h3 class=\"wp-block-heading\">Can any thermal compound be used?<\/h3>\n\n\n<p class=\"wp-block-paragraph\">Use an interface material and process supported for the exact module and assembly.<\/p>\n\n\n<h2 class=\"wp-block-heading\">Produse \u0219i \u00eendrum\u0103ri RITOKS conexe<\/h2>\n\n\n<p class=\"wp-block-paragraph\">Aceste linkuri ofer\u0103 doar informa\u021bii contextuale referitoare la familiile de produse publicate. Un link contextual nu sugereaz\u0103 \u00een niciun fel c\u0103 produsele sunt interschimbabile, compatibile sau c\u0103 reprezint\u0103 o combina\u021bie de sisteme aprobat\u0103.<\/p>\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/ritoks.com\/ro\/product-category\/thermal-management\/power-module-heatsinks\/\">Categoria de produse \u201eRadiatoare pentru module de putere\u201d<\/a><\/p>\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/ritoks.com\/ro\/products\/aluminum-power-module-heatsink-scr-rectifier\/\">Published RITOKS Power Module Heatsink product page<\/a><\/p>\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/ritoks.com\/ro\/products\/sf-forced-air-heatsink-power-modules\/\">Published RITOKS Power Module Heatsink product page<\/a><\/p>\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/ritoks.com\/ro\/heatsink-thermal-resistance-explained\/\">Ghidul tehnic RITOKS publicat pe aceast\u0103 tem\u0103<\/a><\/p>\n\n\n<h2 class=\"wp-block-heading\">Referin\u021be tehnice<\/h2>\n\n\n<p class=\"wp-block-paragraph\">Sursa de mai jos sus\u021bine doar conceptul general de inginerie prezentat \u00een acest ghid. Caracteristicile tehnice ale produselor, schemele electrice, omolog\u0103rile \u0219i rezultatele coordon\u0103rii din aceast\u0103 surs\u0103 nu se aplic\u0103 produselor RITOKS.<\/p>\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.infineon.com\/cms\/en\/product\/power\/igbt\/igbt-modules\/\" target=\"_blank\" rel=\"noopener\">Infineon, Thermal design and mounting guidance for power semiconductor modules<\/a><\/p>\n\n\n<p class=\"wp-block-paragraph\">Supports treating loss, thermal interfaces and mounting as one design chain; Infineon values do not transfer to RITOKS products.<\/p>\n\n\n<h2 class=\"wp-block-heading\">Solicita\u021bi o revizuire a modelului exact<\/h2>\n\n\n<p class=\"wp-block-paragraph\">Trimite\u021bi cerin\u021bele cererii, \u00eentreb\u0103rile referitoare la documentele exacte, cantitatea \u0219i destina\u021bia prin formularul de contact RITOKS. O cerere de ofert\u0103 (RFQ) presupune verificarea modelului exact; acest ghid nu aprob\u0103 niciun circuit, nicio instala\u021bie \u0219i niciun \u00eenlocuitor automat.<\/p>\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/ritoks.com\/ro\/contact-us\/\">Contacta\u021bi RITOKS<\/a><\/p>","protected":false},"excerpt":{"rendered":"<p>Select a power-module heatsink from verified semiconductor loss, thermal path, ambient conditions, airflow, mounting and exact performance evidence.<\/p>","protected":false},"author":1,"featured_media":2015,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ritoks_resource_detail_renderer":"viox","ritoks_resource_product_cat_term_id":137,"footnotes":""},"categories":[69],"tags":[],"class_list":["post-2018","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-enclosure-thermal-management"],"acf":[],"spectra_blocks_featured_image_url":{"thumbnail":{"url":"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/power-module-heatsink-selection-guide-hero-01-150x150.webp","width":150,"height":150},"medium":{"url":"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/power-module-heatsink-selection-guide-hero-01-300x169.webp","width":300,"height":169},"medium_large":{"url":"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/power-module-heatsink-selection-guide-hero-01-768x432.webp","width":768,"height":432},"large":{"url":"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/power-module-heatsink-selection-guide-hero-01-1024x576.webp","width":1024,"height":576},"full":{"url":"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/power-module-heatsink-selection-guide-hero-01.webp","width":1600,"height":900}},"spectra_blocks_author_info":{"display_name":"RITOKS","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/6d7d0fc73468198f994ab13ef6eb6558c53b6ed1ad86364d5165efe8bdf8eb4a?s=96&d=mm&r=g","author_link":"https:\/\/ritoks.com\/ro\/author\/dazzlingwqbgmail-com\/","description":""},"_links":{"self":[{"href":"https:\/\/ritoks.com\/ro\/wp-json\/wp\/v2\/posts\/2018","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ritoks.com\/ro\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ritoks.com\/ro\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ritoks.com\/ro\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/ritoks.com\/ro\/wp-json\/wp\/v2\/comments?post=2018"}],"version-history":[{"count":4,"href":"https:\/\/ritoks.com\/ro\/wp-json\/wp\/v2\/posts\/2018\/revisions"}],"predecessor-version":[{"id":2220,"href":"https:\/\/ritoks.com\/ro\/wp-json\/wp\/v2\/posts\/2018\/revisions\/2220"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ritoks.com\/ro\/wp-json\/wp\/v2\/media\/2015"}],"wp:attachment":[{"href":"https:\/\/ritoks.com\/ro\/wp-json\/wp\/v2\/media?parent=2018"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ritoks.com\/ro\/wp-json\/wp\/v2\/categories?post=2018"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ritoks.com\/ro\/wp-json\/wp\/v2\/tags?post=2018"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}