{"id":699,"date":"2026-09-05T16:51:06","date_gmt":"2026-09-05T16:51:06","guid":{"rendered":"https:\/\/ritoks.com\/?p=699"},"modified":"2026-09-20T06:54:43","modified_gmt":"2026-09-20T06:54:43","slug":"b-curve-vs-c-curve-vs-d-curve-mcb","status":"publish","type":"post","link":"https:\/\/ritoks.com\/ro\/b-curve-vs-c-curve-vs-d-curve-mcb\/","title":{"rendered":"\u00centrerup\u0103toare automate cu curba B, curba C \u0219i curba D: Care este diferen\u021ba?"},"content":{"rendered":"<div class=\"wp-block-group alignfull has-ast-global-color-5-color has-ast-global-color-2-background-color has-text-color has-background is-layout-constrained wp-container-core-group-is-layout-a2d0cf3a wp-block-group-is-layout-constrained\" style=\"padding-top:64px;padding-right:24px;padding-bottom:64px;padding-left:24px\">\n\n\n<h1 class=\"wp-block-heading\">\u00centrerup\u0103toare automate cu curba B, curba C \u0219i curba D: Care este diferen\u021ba?<\/h1>\n\n\n\n<figure data-spectra-id=\"spectra-59ee8d3c-e776-48ad-826d-250fbbf35103\" class=\"wp-block-image aligncenter size-full has-custom-border\" ><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-family-hero.png\" alt=\"Familii reprezentative de \u00eentrerup\u0103toare miniaturale de curent alternativ \u00eentr-un atelier electric industrial\" class=\"wp-image-701\"  width=\"1672\" height=\"941\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-family-hero.png 1672w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-family-hero-600x338.png 600w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-family-hero-300x169.png 300w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-family-hero-1024x576.png 1024w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-family-hero-768x432.png 768w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-family-hero-1536x864.png 1536w\" sizes=\"auto, (max-width: 1672px) 100vw, 1672px\" \/><figcaption class=\"wp-element-caption\">Formate reprezentative de \u00eentrerup\u0103toare de curent alternativ (AC MCB) prezentate \u00eentr-un mediu electric industrial.<\/figcaption><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Curbele B, C \u0219i D reprezint\u0103 diferite caracteristici de declan\u0219are utilizate cu <a href=\"https:\/\/ritoks.com\/ro\/product-category\/ac-power-protection\/miniature-circuit-breakers\/\">\u00eentrerup\u0103toare de circuit miniaturale (MCB)<\/a>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Literele nu indic\u0103 valoarea curentului nominal, capacitatea de \u00eentrerupere sau num\u0103rul de poli. \u00cen schimb, ele ajut\u0103 la descrierea modului \u00een care \u00eentrerup\u0103torul reac\u021bioneaz\u0103 la curen\u021bi de mare intensitate, de scurt\u0103 durat\u0103, \u00een zona sa de declan\u0219are instantanee.<\/p>\n\n\n<\/div>\n\n\n\n<div class=\"wp-block-group alignfull is-layout-constrained wp-container-core-group-is-layout-105ba9aa wp-block-group-is-layout-constrained\" style=\"padding-top:64px;padding-right:24px;padding-bottom:64px;padding-left:24px\">\n\n\n<p class=\"wp-block-paragraph\">Datele tehnice furnizate de produc\u0103tor indic\u0103, de obicei, urm\u0103toarele intervale de valori:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Curba B: aproximativ 3\u20135 \u00d7 In<\/li>\n<li>Curba C: aproximativ 5\u201310 \u00d7 In<\/li>\n<li>Curba D: aproximativ 10\u201320 \u00d7 In<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Aici, In reprezint\u0103 curentul nominal al \u00eentrerup\u0103torului pentru caracteristica la care se face referire. <a href=\"https:\/\/www.eaton.com\/content\/dam\/eaton\/support\/apac-support-assets\/japan-cps-assets\/products\/2023promotions_lp\/sccr2024_pdf01.pdf\" target=\"_blank\" rel=\"noopener\">Documenta\u021bia tehnic\u0103 Eaton<\/a> public\u0103 acelea\u0219i intervale de declan\u0219are la scurtcircuit B, C \u0219i D pentru seriile sale de \u00eentrerup\u0103toare miniaturale.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Diferen\u021ba practic\u0103 const\u0103 \u00een faptul c\u0103 cele trei curbe suport\u0103 niveluri diferite de curent de scurt\u0103 durat\u0103 \u00eenainte de a ajunge \u00een zona de declan\u0219are instantanee.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Asta nu \u00eenseamn\u0103 c\u0103 o curb\u0103 este, \u00een mod universal, mai bun\u0103 dec\u00e2t alta.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Curba necesar\u0103 ar trebui s\u0103 rezulte din proiectul electric propriu-zis, din condi\u021biile de curent de pornire preconizate \u0219i din documenta\u021bia aferent\u0103 \u00eentrerup\u0103torului selectat.<\/p>\n\n\n\n<h2 id=\"in-this-guide\" class=\"wp-block-heading\">\u00cen acest ghid<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"#quick-comparison\">Compara\u021bie rapid\u0103: Curba B vs Curba C vs Curba D<\/a><\/li>\n<li><a href=\"#mcb-trip-curve\">Ce este o curb\u0103 de declan\u0219are a unui disjunctor miniaturizat (MCB)?<\/a><\/li>\n<li><a href=\"#b-curve\">Ce este un \u00eentrerup\u0103tor automat de tip B?<\/a><\/li>\n<li><a href=\"#c-curve\">Ce este un \u00eentrerup\u0103tor automat de tip C?<\/a><\/li>\n<li><a href=\"#d-curve\">Ce este un \u00eentrerup\u0103tor automat cu curba D?<\/a><\/li>\n<li><a href=\"#curve-availability\">Disponibilitatea actual\u0103 a curbelor RITOKS<\/a><\/li>\n<li><a href=\"#selection-process\">Cum s\u0103 alegi \u00eentre op\u021biunile de curbe B, C \u0219i D<\/a><\/li>\n<li><a href=\"#frequently-asked-questions\">\u00centreb\u0103ri frecvente<\/a><\/li>\n<\/ul>\n\n\n\n<h2 id=\"quick-comparison\" class=\"wp-block-heading\">Compara\u021bie rapid\u0103: Curba B vs Curba C vs Curba D<\/h2>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table><thead><tr><th>Caracteristic\u0103<\/th><th>Zona comun\u0103 de declan\u0219are instantanee<\/th><th>Context general privind curentul de pornire<\/th><\/tr><\/thead><tbody><tr><td>Curba B<\/td><td>3\u20135 \u00d7 In<\/td><td>Se preconizeaz\u0103 un curent de pornire mai mic<\/td><\/tr><tr><td>Curba C<\/td><td>5\u201310 \u00d7 In<\/td><td>Se preconizeaz\u0103 un curent de pornire moderat<\/td><\/tr><tr><td>Curba D<\/td><td>10\u201320 \u00d7 In<\/td><td>Se preconizeaz\u0103 un curent de pornire mai mare<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Aceste intervale descriu caracteristicile generale documentate de principalii produc\u0103tori de MCB. Ele nu trebuie considerate ca fiind o curb\u0103 timp-curent RITOKS specific\u0103 unui anumit model, cu excep\u021bia cazului \u00een care documenta\u021bia exact\u0103 a produsului RITOKS confirm\u0103 acest lucru.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.eaton.com\/content\/dam\/eaton\/products\/electrical-circuit-protection\/industrial-miniature-circuit-breakers\/Industrial-breakers-catalog-ca08100005e.pdf\" target=\"_blank\" rel=\"noopener\">Ghidul Eaton privind \u00eentrerup\u0103toarele miniaturale industriale<\/a>, de exemplu, caracteristica B este descris\u0103 pentru situa\u021bii cu curent de pornire redus, caracteristica C pentru situa\u021bii cu curent de pornire mediu, iar caracteristica D pentru situa\u021bii cu curent de pornire ridicat. Ghidul de aplicare al standardului ofer\u0103 exemple precum transformatoarele mici \u0219i echipamentele de control pentru caracteristica C, precum \u0219i echipamentele cu curent de pornire ridicat, cum ar fi motoarele, transformatoarele \u0219i sursele de alimentare, pentru caracteristica D. Acestea sunt exemple tipice, nu reguli universale de selectare a sarcinilor.<\/p>\n\n\n\n<figure data-spectra-id=\"spectra-1b1e345d-6950-4712-aa60-bf6ce3a234dd\" class=\"wp-block-image aligncenter size-full has-custom-border\" ><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/b-c-d-curve-options-comparison.png\" alt=\"Compara\u021bie conceptual\u0103 \u00eentre op\u021biunile MCB cu curbe B, C \u0219i D\" class=\"wp-image-702\"  width=\"1672\" height=\"941\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/b-c-d-curve-options-comparison.png 1672w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/b-c-d-curve-options-comparison-600x338.png 600w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/b-c-d-curve-options-comparison-300x169.png 300w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/b-c-d-curve-options-comparison-1024x576.png 1024w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/b-c-d-curve-options-comparison-768x432.png 768w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/b-c-d-curve-options-comparison-1536x864.png 1536w\" sizes=\"auto, (max-width: 1672px) 100vw, 1672px\" \/><figcaption class=\"wp-element-caption\">Compara\u021bie conceptual\u0103 \u00eentre curbele B, C \u0219i D. Denumirea curbei reprezint\u0103 unul dintre parametrii de selec\u021bie, iar documenta\u021bia exact\u0103 a modelului trebuie verificat\u0103.<\/figcaption><\/figure>\n\n\n\n<h2 id=\"mcb-trip-curve\" class=\"wp-block-heading\">Ce este o curb\u0103 de declan\u0219are a unui disjunctor miniaturizat (MCB)?<\/h2>\n\n\n<p class=\"wp-block-paragraph\">Un \u00eentrerup\u0103tor automat de curent (MCB) protejeaz\u0103 un circuit \u00eempotriva supratensiunilor, dar modul \u00een care acesta reac\u021bioneaz\u0103 nu depinde doar de valoarea nominal\u0103 a curentului s\u0103u.<\/p>\n<p class=\"wp-block-paragraph\">O caracteristic\u0103 a c\u0103l\u0103toriei descrie o parte din acel r\u0103spuns.<\/p>\n<p class=\"wp-block-paragraph\">\u00cen cazul \u00eentreruptoarelor magneto-termice (MCB) de tip B, C \u0219i D, una dintre cele mai evidente diferen\u021be o reprezint\u0103 zona de declan\u0219are instantanee sau magnetic\u0103.<\/p>\n<p class=\"wp-block-paragraph\">S\u0103 lu\u0103m \u00een considerare dou\u0103 \u00eentrerup\u0103toare cu acela\u0219i curent nominal.<\/p>\n<p class=\"wp-block-paragraph\">Un \u00eentrerup\u0103tor de tip B \u0219i unul de tip D pot suporta am\u00e2ndoi acela\u0219i curent nominal \u00een condi\u021bii normale, dar zonele lor de declan\u0219are instantanee pot diferi substan\u021bial.<\/p>\n<p class=\"wp-block-paragraph\">De aceea:<\/p>\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p class=\"wp-block-paragraph\">\u201cCurba 32 A B\u201d \u0219i \u201ccurba 32 A D\u201d nu descriu un comportament de protec\u021bie identic doar pentru c\u0103 ambele \u00eentrerup\u0103toare au o intensitate nominal\u0103 de 32 A.<\/p><\/blockquote>\n\n\n<p class=\"wp-block-paragraph\">Prin urmare, curba reprezint\u0103 un alt parametru de selec\u021bie, al\u0103turi de:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>curent nominal<\/li>\n<li>tensiune<\/li>\n<li>st\u00e2lpi<\/li>\n<li>capacitatea de rupere<\/li>\n<li>modul de montare<\/li>\n<li>modelul exact<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Pentru mai multe informa\u021bii despre procesul de selec\u021bie, consulta\u021bi <a href=\"https:\/\/ritoks.com\/ro\/ac-mcb-selection-guide\/\">Ghid de selectare a \u00eentreruptoarelor magneto-termice (MCB) de curent alternativ: curent, poli, curb\u0103 de declan\u0219are \u0219i capacitate de \u00eentrerupere<\/a>.<\/p>\n\n\n\n<h2 id=\"b-curve\" class=\"wp-block-heading\">Ce este un \u00eentrerup\u0103tor automat de tip B?<\/h2>\n\n\n<p class=\"wp-block-paragraph\">O caracteristic\u0103 de tip A-B utilizeaz\u0103, de obicei, o zon\u0103 de declan\u0219are instantanee cuprins\u0103 \u00eentre aproximativ 3 \u0219i 5 ori valoarea curentului nominal.<\/p>\n<p class=\"wp-block-paragraph\">\u00cen termeni generali, aceasta \u00eenseamn\u0103 c\u0103 se ajunge la domeniul magnetic instantaneu la un multiplu mai mic al curentului nominal dec\u00e2t \u00een cazul caracteristicilor de tip C sau D.<\/p>\n<p class=\"wp-block-paragraph\">Conform recomand\u0103rilor produc\u0103torului, caracteristicile de tip B sunt utilizate de obicei \u00een situa\u021biile \u00een care se preconizeaz\u0103 un curent de pornire relativ redus.<\/p>\n<p class=\"wp-block-paragraph\">Totu\u0219i, acest lucru nu ar trebui transformat \u00eentr-o regul\u0103 de genul:<\/p>\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p class=\"wp-block-paragraph\">\u201cToate circuitele de iluminat trebuie s\u0103 utilizeze curba B.\u201d<\/p><\/blockquote>\n<p class=\"wp-block-paragraph\">Alegerea efectiv\u0103 depinde de circuit, de curentul de pornire preconizat, de condi\u021biile de defect \u0219i de cerin\u021bele de proiectare aplicabile.<\/p>\n\n\n<h3 class=\"wp-block-heading\">Disponibilitatea actual\u0103 a curbei B RITOKS<\/h3>\n\n\n<p class=\"wp-block-paragraph\">Publicat recent <a href=\"https:\/\/ritoks.com\/ro\/product-category\/ac-power-protection\/\">Date privind disjunctorul de curent alternativ RITOKS AC MCB<\/a> confirm\u0103 disponibilitatea curbei B pe:<\/p>\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/ritoks.com\/ro\/products\/miniature-circuit-breaker-63a-10ka\/\">RTSXD01<\/a> \u2014 B \/ C \/ D<\/li>\n<li>RTSXD03 \u2014 B \/ C<\/li>\n<li><a href=\"https:\/\/ritoks.com\/ro\/products\/1pn-miniature-circuit-breaker-32a-6ka\/\">RTSXD02<\/a> \u2014 B \/ C<\/li>\n<li><a href=\"https:\/\/ritoks.com\/ro\/products\/miniature-circuit-breaker-63a-10ka-pro\/\">RTSXD04<\/a> \u2014 B \/ C \/ D<\/li>\n<li><a href=\"https:\/\/ritoks.com\/ro\/products\/m60-ac-miniature-circuit-breaker-6-63a\/\">RTS-ACM60<\/a> \u2014 B \/ C<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">Curba de deplasare pentru RTS-AC47 nu este confirmat\u0103 \u00een prezent.<\/p>\n<p class=\"wp-block-paragraph\">Aceste \u00eenregistr\u0103ri confirm\u0103 doar disponibilitatea. Ele nu stabilesc comportamentul exact al curentului \u00een func\u021bie de timp pentru un anumit model, dincolo de datele curbei publicate.<\/p>\n\n\n<h2 id=\"c-curve\" class=\"wp-block-heading\">Ce este un \u00eentrerup\u0103tor automat de tip C?<\/h2>\n\n\n<p class=\"wp-block-paragraph\">O caracteristic\u0103 de tip C utilizeaz\u0103, de obicei, o zon\u0103 de declan\u0219are instantanee de aproximativ 5\u201310 ori curentul nominal.<\/p>\n<p class=\"wp-block-paragraph\">\u00cen compara\u021bie cu caracteristica B, aceasta permite un multiplu mai mare al curentului de scurt\u0103 durat\u0103 \u00eenainte de a intra \u00een zona de declan\u0219are instantanee.<\/p>\n<p class=\"wp-block-paragraph\">Eaton descrie caracteristica C ca fiind potrivit\u0103 pentru situa\u021bii cu curent de pornire mediu \u0219i ofer\u0103 exemple precum transformatoare mici, sisteme de iluminat, dispozitive de semnalizare, circuite de comand\u0103 \u0219i bobine. Acesta este un context general util, dar nu \u00eenseamn\u0103 c\u0103 fiecare dintre aceste aplica\u021bii necesit\u0103 \u00een mod automat o curb\u0103 C.<\/p>\n\n\n<h3 class=\"wp-block-heading\">Disponibilitatea actual\u0103 a curbei C RITOKS<\/h3>\n\n<p class=\"wp-block-paragraph\">Curba C este, \u00een prezent, cea mai larg confirmat\u0103 dintre toate familiile RITOKS AC MCB publicate:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>RTSXD01 \u2014 B \/ C \/ D<\/li>\n<li>RTSXD03 \u2014 B \/ C<\/li>\n<li>RTSXD02 \u2014 B \/ C<\/li>\n<li>RTSXD04 \u2014 B \/ C \/ D<\/li>\n<li>RTS-ACM60 \u2014 B \/ C<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">Din nou, modelul RTS-AC47 nu are \u00een prezent nicio denumire de curbur\u0103 confirmat\u0103 pe site.<\/p>\n\n\n<h2 id=\"d-curve\" class=\"wp-block-heading\">Ce este un \u00eentrerup\u0103tor automat cu curba D?<\/h2>\n\n\n<p class=\"wp-block-paragraph\">O caracteristic\u0103 de tip D utilizeaz\u0103, de obicei, o zon\u0103 de declan\u0219are instantanee cuprins\u0103 \u00eentre aproximativ 10 \u0219i 20 de ori valoarea curentului nominal.<\/p>\n<p class=\"wp-block-paragraph\">Aceasta este cea mai \u00eenalt\u0103 dintre cele trei regiuni instantanee obi\u0219nuite discutate aici.<\/p>\n<p class=\"wp-block-paragraph\">Instruc\u021biunile produc\u0103torului asociaz\u0103 adesea caracteristicile D cu echipamentele care prezint\u0103 un curent de pornire mai mare. Eaton men\u021bioneaz\u0103 motoarele, transformatoarele, sursele de alimentare \u0219i alte sisteme cu inductan\u021b\u0103 ridicat\u0103 ca exemple tipice.<\/p>\n<p class=\"wp-block-paragraph\">Cuv\u00e2ntul \u201etipic\u201d are o importan\u021b\u0103 deosebit\u0103.<\/p>\n<p class=\"wp-block-paragraph\">Ar fi riscant s\u0103 tragem concluzia c\u0103:<\/p>\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p class=\"wp-block-paragraph\">\u201cMotor = curba D.\u201d<\/p><\/blockquote>\n<p class=\"wp-block-paragraph\">Un circuit electric poate implica numeroase variabile, printre care caracteristicile de pornire \u0219i proiectarea general\u0103 a sistemului de protec\u021bie. Prin urmare, curba \u00eentrerup\u0103torului trebuie selectat\u0103 pe baza unor cerin\u021be tehnice verificate, \u0219i nu doar pe baza denumirii echipamentului.<\/p>\n\n\n<h3 class=\"wp-block-heading\">Disponibilitatea actual\u0103 a curbei D RITOKS<\/h3>\n\n<p class=\"wp-block-paragraph\">Datele RITOKS publicate recent confirm\u0103 curba D \u00een ceea ce prive\u0219te:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>RTSXD01<\/li>\n<li>RTSXD04<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">Celelalte familii de \u00eentrerup\u0103toare magneto-termice (MCB) de la AC publicate \u00een prezent nu au men\u021bionat\u0103 disponibilitatea curbei D pe paginile lor de produs.<\/p>\n\n\n<h2 id=\"why-curves-differ\" class=\"wp-block-heading\">De ce curbele utilizeaz\u0103 regiuni instantanee diferite<\/h2>\n\n\n<p class=\"wp-block-paragraph\">Echipamentele electrice pot consuma un curent mai mare dec\u00e2t nivelul lor normal de func\u021bionare pentru o perioad\u0103 scurt\u0103 de timp.<\/p>\n<p class=\"wp-block-paragraph\">Acest lucru se poate \u00eent\u00e2mpla \u00een timpul unor opera\u021biuni precum alimentarea cu energie sau punerea \u00een func\u021biune.<\/p>\n<p class=\"wp-block-paragraph\">Dac\u0103 zona de declan\u0219are instantanee a \u00eentrerup\u0103torului este prea joas\u0103 pentru curentul de scurt\u0103 durat\u0103 preconizat, \u00eentrerup\u0103torul se poate declan\u0219a chiar dac\u0103 evenimentul a f\u0103cut parte din procesul normal de pornire a echipamentului.<\/p>\n<p class=\"wp-block-paragraph\">Pe de alt\u0103 parte, simpla alegere a unei curbe cu o regiune instantanee mai mare nu \u00eenseamn\u0103 neap\u0103rat c\u0103 aceasta este mai bun\u0103.<\/p>\n<p class=\"wp-block-paragraph\">Sistemul de protec\u021bie trebuie \u00eenc\u0103 s\u0103 reac\u021bioneze \u00een mod adecvat la defec\u021biunile reale.<\/p>\n<p class=\"wp-block-paragraph\">De aceea, caracteristicile B, C \u0219i D trebuie \u00een\u021belese ca fiind caracteristici de protec\u021bie diferite, \u0219i nu ca niveluri de calitate.<\/p>\n<p class=\"wp-block-paragraph\">D nu este o versiune \u201cpremium\u201d a limbajului C, iar C nu este o \u201cversiune \u00eembun\u0103t\u0103\u021bit\u0103\u201d a limbajului B.<\/p>\n\n\n<h2 id=\"same-rated-current\" class=\"wp-block-heading\">B vs C vs D la acela\u0219i curent nominal<\/h2>\n\n\n<p class=\"wp-block-paragraph\">Imagina\u021bi-v\u0103 trei \u00eentrerup\u0103toare magneto-termice (MCB) care au toate acela\u0219i curent nominal, In.<\/p>\n<p class=\"wp-block-paragraph\">Folosind intervalele caracteristice obi\u0219nuite:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>B ajunge \u00een zona sa instantanee \u00een jurul valorii de 3\u20135 \u00d7 In<\/li>\n<li>C aproximativ 5\u201310 \u00d7 In<\/li>\n<li>D aproximativ 10\u201320 \u00d7 In<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">Doar cu titlu ilustrativ, dac\u0103 In = 10 A, ace\u0219ti multipli corespund matematic cu:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>B: aproximativ 30\u201350 A<\/li>\n<li>C: aproximativ 50\u2013100 A<\/li>\n<li>D: aproximativ 100\u2013200 A<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">Acest exemplu aritmetic ilustreaz\u0103 doar semnifica\u021bia multiplilor. Nu reprezint\u0103 o recomandare privind alegerea produsului \u0219i nu trebuie considerat ca fiind comportamentul exact de func\u021bionare al unui \u00eentrerup\u0103tor RITOKS specific.<\/p>\n<p class=\"wp-block-paragraph\">Comportamentul real al \u00eentrerup\u0103torului trebuie verificat \u00een raport cu documenta\u021bia exact\u0103 a produc\u0103torului privind rela\u021bia timp-curent \u0219i cu cerin\u021bele aplicabile produsului.<\/p>\n\n\n<h2 id=\"curve-availability\" class=\"wp-block-heading\">Prezentare general\u0103 a disponibilit\u0103\u021bii actuale a curbei RITOKS<\/h2>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table><thead><tr><th>Modelul RITOKS<\/th><th>B<\/th><th>C<\/th><th>D<\/th><th>Date actuale<\/th><\/tr><\/thead><tbody><tr><td>RTSXD01<\/td><td>Da<\/td><td>Da<\/td><td>Da<\/td><td>Disponibilitate publicat\u0103<\/td><\/tr><tr><td>RTSXD03<\/td><td>Da<\/td><td>Da<\/td><td>\u2014<\/td><td>Disponibilitate publicat\u0103<\/td><\/tr><tr><td>RTSXD02<\/td><td>Da<\/td><td>Da<\/td><td>\u2014<\/td><td>Disponibilitate publicat\u0103<\/td><\/tr><tr><td>RTSXD04<\/td><td>Da<\/td><td>Da<\/td><td>Da<\/td><td>Disponibilitate publicat\u0103<\/td><\/tr><tr><td>RTS-ACM60<\/td><td>Da<\/td><td>Da<\/td><td>\u2014<\/td><td>Disponibilitate publicat\u0103<\/td><\/tr><tr><td>RTS-AC47<\/td><td>Neconfirmat<\/td><td>Neconfirmat<\/td><td>Neconfirmat<\/td><td>Curba nu a fost confirmat\u0103<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n<p class=\"wp-block-paragraph\">Acest tabel trebuie utilizat exclusiv pentru preselec\u021bia familiilor de produse.<\/p>\n<p class=\"wp-block-paragraph\">Aceasta nu \u00eenseamn\u0103 c\u0103 curbele furnizate de produc\u0103torul extern, men\u021bionate anterior, reprezint\u0103 exact curbele timp-curent testate ale acestor modele RITOKS.<\/p>\n\n\n<figure data-spectra-id=\"spectra-8d94b6b3-bff5-475a-b500-eea3cb1beecf\" class=\"wp-block-image aligncenter size-full has-custom-border\" ><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-pole-formats-panel.png\" alt=\"Diferite configura\u021bii ale polilor \u00eentreruptoarelor miniaturale de curent alternativ \u00eentr-un tablou de distribu\u021bie industrial\" class=\"wp-image-703\"  width=\"1672\" height=\"941\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-pole-formats-panel.png 1672w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-pole-formats-panel-600x338.png 600w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-pole-formats-panel-300x169.png 300w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-pole-formats-panel-1024x576.png 1024w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-pole-formats-panel-768x432.png 768w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-pole-formats-panel-1536x864.png 1536w\" sizes=\"auto, (max-width: 1672px) 100vw, 1672px\" \/><figcaption class=\"wp-element-caption\">Exemple de formate ale produselor AC MCB; disponibilitatea curbelor \u0219i valorile nominale electrice trebuie confirmate pentru modelul exact.<\/figcaption><\/figure>\n\n\n\n<h2 id=\"selection-process\" class=\"wp-block-heading\">Cum s\u0103 alegi \u00eentre op\u021biunile de curbe B, C \u0219i D<\/h2>\n\n\n<p class=\"wp-block-paragraph\">Procesul practic de aprovizionare \u00eencepe cu caracteristica necesar\u0103, nu cu o presupunere bazat\u0103 pe denumirea produsului.<\/p>\n\n<h3 class=\"wp-block-heading\">1. Confirma\u021bi cerin\u021bele privind sarcina \u0219i curentul de pornire<\/h3>\n<p class=\"wp-block-paragraph\">Stabili\u021bi dac\u0103 documenta\u021bia proiectului prevede deja:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>curentul de pornire preconizat<\/li>\n<li>comportamentul la pornire<\/li>\n<li>curba necesar\u0103<\/li>\n<li>alte restric\u021bii legate de protec\u021bie<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">Dac\u0103 curba dorit\u0103 a fost deja specificat\u0103, folosi\u021bi-o ca punct de plecare.<\/p>\n\n<h3 class=\"wp-block-heading\">2. Confirma\u021bi curentul nominal<\/h3>\n<p class=\"wp-block-paragraph\">Curba de declan\u0219are \u0219i curentul nominal sunt parametri distinc\u021bi.<\/p>\n<p class=\"wp-block-paragraph\">De exemplu:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>C16<\/li>\n<li>C32<\/li>\n<li>C63<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">toate poart\u0103 denumirea \u201eC\u201d, dar au intensit\u0103\u021bi nominale diferite.<\/p>\n<p class=\"wp-block-paragraph\">Nu selecta\u021bi mai \u00eent\u00e2i curba \u0219i nu ignora\u021bi curentul necesar al \u00eentrerup\u0103torului.<\/p>\n\n<h3 class=\"wp-block-heading\">3. Confirma\u021bi capacitatea de rupere<\/h3>\n<p class=\"wp-block-paragraph\">Curba de deplasare \u0219i <a href=\"https:\/\/ritoks.com\/ro\/6ka-vs-10ka-mcb-breaking-capacity\/\">Capacitate de \u00eentrerupere a \u00eentrerup\u0103torului automat de curent (MCB) de 6 kA fa\u021b\u0103 de 10 kA<\/a> sunt, de asemenea, parametri diferi\u021bi.<\/p>\n<p class=\"wp-block-paragraph\">O clasificare de tipul A, B, C sau D nu indic\u0103 dac\u0103 \u00eentrerup\u0103torul are:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>6 kA<\/li>\n<li>10 kA<\/li>\n<li>sau o alt\u0103 valoare a capacit\u0103\u021bii de rupere<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">Aceast\u0103 caracteristic\u0103 trebuie verificat\u0103 separat pentru produsul respectiv.<\/p>\n\n<h3 class=\"wp-block-heading\">4. Confirma\u021bi configura\u021bia st\u00e2lpului<\/h3>\n<p class=\"wp-block-paragraph\">O curb\u0103 B\/C\/D obligatorie poate fi util\u0103 numai dac\u0103 aceea\u0219i familie de produse ofer\u0103, de asemenea, urm\u0103toarele cerin\u021be:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>1P<\/li>\n<li>1P+N<\/li>\n<li>2P<\/li>\n<li>3P<\/li>\n<li>3P+N<\/li>\n<li>4P<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">configura\u021bie.<\/p>\n\n<h3 class=\"wp-block-heading\">5. Verifica\u021bi documenta\u021bia exact\u0103 a produsului<\/h3>\n<p class=\"wp-block-paragraph\">Ultimul pas const\u0103 \u00een verificarea propriu-zis\u0103 a \u00eentrerup\u0103torului selectat.<\/p>\n<p class=\"wp-block-paragraph\">Nu presupune\u021bi c\u0103:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>fiecare curb\u0103 B se comport\u0103 identic la to\u021bi produc\u0103torii<\/li>\n<li>fiecare curb\u0103 C are toleran\u021be identice timp-curent<\/li>\n<li>fiecare curba D este potrivit\u0103 pentru orice sarcin\u0103 cu curent de pornire ridicat<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">Denumirea curbei reprezint\u0103 o parte a specifica\u021biei complete a produsului.<\/p>\n\n\n<h2 id=\"common-mistakes\" class=\"wp-block-heading\">Gre\u0219eli frecvente \u00een alegerea curbelor B\/C\/D<\/h2>\n\n\n<h3 class=\"wp-block-heading\">Considerarea nivelurilor B, C \u0219i D ca niveluri de calitate<\/h3>\n<p class=\"wp-block-paragraph\">Sunt caracteristici diferite ale c\u0103l\u0103toriei, nu \u201cde baz\u0103\u201d, \u201cmai bune\u201d \u0219i \u201ccele mai bune\u201d.\u201d<\/p>\n\n<h3 class=\"wp-block-heading\">Selectarea doar pe baza numelui \u00eenc\u0103rc\u0103turii<\/h3>\n<p class=\"wp-block-paragraph\">Afirma\u021bii precum \u201cmotor \u00eenseamn\u0103 curba D\u201d sunt prea generale.<\/p>\n<p class=\"wp-block-paragraph\">Trebuie luate \u00een considerare curentul de pornire preconizat \u0219i proiectarea electric\u0103 efectiv\u0103.<\/p>\n\n<h3 class=\"wp-block-heading\">Ignorarea curentului nominal<\/h3>\n<p class=\"wp-block-paragraph\">O curba corect\u0103, combinat\u0103 cu o intensitate nominal\u0103 incorect\u0103, nu reprezint\u0103 o alegere corect\u0103 a \u00eentrerup\u0103torului.<\/p>\n\n<h3 class=\"wp-block-heading\">Ignorarea capacit\u0103\u021bii de rupere<\/h3>\n<p class=\"wp-block-paragraph\">Caracteristica B\/C\/D \u0219i capacitatea de fr\u00e2nare sunt parametri distincti.<\/p>\n\n<h3 class=\"wp-block-heading\">Presupun\u00e2nd c\u0103 datele curbelor externe se aplic\u0103 automat fiec\u0103rui model RITOKS<\/h3>\n<p class=\"wp-block-paragraph\">Valorile de 3\u20135 \u00d7 In, 5\u201310 \u00d7 In \u0219i 10\u201320 \u00d7 In utilizate \u00een acest ghid reprezint\u0103 intervale caracteristice generale, sus\u021binute de documenta\u021bia tehnic\u0103 oficial\u0103 a produc\u0103torului. Paginile de produse RITOKS confirm\u0103 \u00een prezent care litere ale curbelor sunt disponibile, dar nu public\u0103 curbele complete de timp-curent specifice fiec\u0103rui model.<\/p>\n\n<h3 class=\"wp-block-heading\">Crearea unui grafic curbat f\u0103r\u0103 date de model<\/h3>\n<p class=\"wp-block-paragraph\">Un grafic cu aspect realist poate sugera o precizie mai mare dec\u00e2t o sus\u021bin datele disponibile.<\/p>\n<p class=\"wp-block-paragraph\">P\u00e2n\u0103 c\u00e2nd vor fi disponibile date exacte privind rela\u021bia timp-curent specifice modelului RITOKS, alegerea curbei trebuie s\u0103 se bazeze pe denumirea publicat\u0103 \u0219i pe cerin\u021bele proiectului, \u0219i nu pe un grafic inventat.<\/p>\n\n\n<h2 id=\"request-technical-data\" class=\"wp-block-heading\">C\u00e2nd ar trebui s\u0103 solicita\u021bi mai multe date tehnice?<\/h2>\n\n\n<p class=\"wp-block-paragraph\">\u00cen cazul unei solicit\u0103ri de ofert\u0103 de rutin\u0103, cunoa\u0219terea denumirii curbei necesare poate fi suficient\u0103 pentru a selecta modelele disponibile.<\/p>\n<p class=\"wp-block-paragraph\">Pentru o analiz\u0103 tehnic\u0103 mai detaliat\u0103, cump\u0103r\u0103torii ar putea avea nevoie de documente suplimentare, cum ar fi:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>caracteristica exact\u0103 timp-curent<\/li>\n<li>toleran\u021b\u0103 la declan\u0219are instantanee<\/li>\n<li>date privind capacitatea maxim\u0103<\/li>\n<li>standardul aplicabil produsului<\/li>\n<li>informa\u021bii privind coordonarea, acolo unde este necesar<\/li>\n<li>documente de testare sau de certificare specifice modelului<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">Aceste cerin\u021be ar trebui solicitate pentru produsul concret, \u0219i nu deduse doar pe baza literelor B, C sau D.<\/p>\n\n\n<h2 id=\"frequently-asked-questions\" class=\"wp-block-heading\">\u00centreb\u0103ri frecvente<\/h2>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Care este diferen\u021ba principal\u0103 dintre \u00eentrerup\u0103toarele automate cu curbe B, C \u0219i D?<\/summary>\n<p class=\"wp-block-paragraph\">Principala diferen\u021b\u0103 discutat\u0103 aici este zona de declan\u0219are instantanee. Documenta\u021bia obi\u0219nuit\u0103 a produc\u0103torilor utilizeaz\u0103 valori de aproximativ 3\u20135 \u00d7 In pentru B, 5\u201310 \u00d7 In pentru C \u0219i 10\u201320 \u00d7 In pentru D.<\/p>\n<\/details>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Curba C este mai bun\u0103 dec\u00e2t curba B?<\/summary>\n<p class=\"wp-block-paragraph\">Nu. Acestea au caracteristici de declan\u0219are diferite. Alegerea potrivit\u0103 depinde de circuit \u0219i de condi\u021biile de curent de pornire preconizate.<\/p>\n<\/details>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Curba D se folose\u0219te \u00eentotdeauna pentru motoare?<\/summary>\n<p class=\"wp-block-paragraph\">Nu. Curba D este asociat\u0103 \u00een mod obi\u0219nuit cu aplica\u021bii cu curent de pornire mai mare, iar instruc\u021biunile produc\u0103torului men\u021bioneaz\u0103 adesea motoarele \u0219i transformatoarele ca exemple, \u00eens\u0103 curba corect\u0103 depinde de echipamentul propriu-zis \u0219i de proiectarea sistemului de protec\u021bie.<\/p>\n<\/details>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>RITOKS ofer\u0103 \u00eentrerup\u0103toare magneto-termice (MCB) pentru curbele B, C \u0219i D?<\/summary>\n<p class=\"wp-block-paragraph\">Da, pentru anumite serii. Modelele RTSXD01 \u0219i RTSXD04 prezint\u0103 \u00een prezent op\u021biunile B\/C\/D. Modelele RTSXD02, RTSXD03 \u0219i RTS-ACM60 prezint\u0103 op\u021biunile B\/C. Modelul RTS-AC47 nu are, \u00een prezent, o denumire confirmat\u0103 a curbei.<\/p>\n<\/details>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>O scrisoare de curbur\u0103 \u00eemi indic\u0103 capacitatea de rupere?<\/summary>\n<p class=\"wp-block-paragraph\">Nu. Caracteristica cursei \u0219i capacitatea de fr\u00e2nare sunt parametri de produs distincti \u0219i trebuie verifica\u021bi am\u00e2ndoi.<\/p>\n<\/details>\n\n\n\n<div class=\"wp-block-group has-ast-global-color-5-color has-ast-global-color-2-background-color has-text-color has-background is-layout-constrained wp-container-core-group-is-layout-737f6912 wp-block-group-is-layout-constrained\" style=\"border-radius:6px;margin-top:48px;padding-top:40px;padding-right:32px;padding-bottom:40px;padding-left:32px\">\n\n\n<h2 class=\"wp-block-heading\">Ave\u021bi nevoie de ajutor pentru a alege o curb\u0103 de declan\u0219are a unui MCB?<\/h2>\n\n\n<p class=\"wp-block-paragraph\">RITOKS ofer\u0103 serii de \u00eentrerup\u0103toare miniaturale de curent alternativ cu diferite valori nominale ale curentului, configura\u021bii ale polilor, capacit\u0103\u021bi de \u00eentrerupere \u0219i disponibilitatea curbelor B\/C\/D.<\/p>\n<p class=\"wp-block-paragraph\">Folosi\u021bi un <a href=\"https:\/\/ritoks.com\/ro\/ac-mcb-rfq-checklist\/\">Lista de verificare pentru cererea de ofert\u0103 privind AC, MCB \u0219i RFQ<\/a> s\u0103 asigure:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>Tensiune alternativ\u0103<\/li>\n<li>curentul necesar<\/li>\n<li>configura\u021bia st\u00e2lpilor<\/li>\n<li>curba de deplasare necesar\u0103<\/li>\n<li>capacitatea de rupere necesar\u0103<\/li>\n<li>cantitate<\/li>\n<li>cerere<\/li>\n<li>orice documenta\u021bie tehnic\u0103 necesar\u0103<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">RITOKS poate apoi s\u0103 coreleze cererea cu familiile de produse publicate \u00een prezent \u0219i cu datele confirmate privind modelele.<\/p>\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-ast-global-color-0-background-color has-background wp-element-button\" href=\"https:\/\/ritoks.com\/ro\/product-category\/ac-power-protection\/miniature-circuit-breakers\/\">Vezi \u00eentrerup\u0103toarele miniaturale de curent alternativ \u2192<\/a><\/div>\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-ast-global-color-0-background-color has-background wp-element-button\" href=\"https:\/\/ritoks.com\/ro\/ac-mcb-selection-guide\/\">Citi\u021bi Ghidul de selectare a \u00eentrerup\u0103torilor magneto-termice (MCB) AC \u2192<\/a><\/div>\n<div class=\"wp-block-button is-style-outline is-style-outline--1\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/ritoks.com\/ro\/contact-us\/\">Contacta\u021bi RITOKS \u2192 Solicita\u021bi o ofert\u0103 de pre\u021b<\/a><\/div>\n<\/div>\n\n\n<\/div>\n\n\n<\/div>","protected":false},"excerpt":{"rendered":"<p>B Curve vs C Curve vs D Curve MCBs: What\u2019s the Difference? B, C and D curves are different tripping [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"no-sidebar","site-content-layout":"page-builder","ast-site-content-layout":"full-width-container","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"disabled","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"disabled","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ritoks_resource_detail_renderer":null,"ritoks_resource_product_cat_term_id":0,"footnotes":""},"categories":[64],"tags":[],"class_list":["post-699","post","type-post","status-publish","format-standard","hentry","category-circuit-protection"],"acf":[],"spectra_blocks_featured_image_url":null,"spectra_blocks_author_info":{"display_name":"RITOKS","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/6d7d0fc73468198f994ab13ef6eb6558c53b6ed1ad86364d5165efe8bdf8eb4a?s=96&d=mm&r=g","author_link":"https:\/\/ritoks.com\/ro\/author\/dazzlingwqbgmail-com\/","description":""},"_links":{"self":[{"href":"https:\/\/ritoks.com\/ro\/wp-json\/wp\/v2\/posts\/699","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ritoks.com\/ro\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ritoks.com\/ro\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ritoks.com\/ro\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/ritoks.com\/ro\/wp-json\/wp\/v2\/comments?post=699"}],"version-history":[{"count":4,"href":"https:\/\/ritoks.com\/ro\/wp-json\/wp\/v2\/posts\/699\/revisions"}],"predecessor-version":[{"id":731,"href":"https:\/\/ritoks.com\/ro\/wp-json\/wp\/v2\/posts\/699\/revisions\/731"}],"wp:attachment":[{"href":"https:\/\/ritoks.com\/ro\/wp-json\/wp\/v2\/media?parent=699"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ritoks.com\/ro\/wp-json\/wp\/v2\/categories?post=699"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ritoks.com\/ro\/wp-json\/wp\/v2\/tags?post=699"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}