{"id":789,"date":"2026-09-08T04:14:10","date_gmt":"2026-09-08T04:14:10","guid":{"rendered":"https:\/\/ritoks.com\/?p=789"},"modified":"2026-10-11T00:44:30","modified_gmt":"2026-10-11T00:44:30","slug":"current-transformer-selection-guide","status":"publish","type":"post","link":"https:\/\/ritoks.com\/ro\/current-transformer-selection-guide\/","title":{"rendered":"Ghid de selectare a transformatoarelor de curent: construc\u021bie, raport de transformare, ie\u0219ire \u0219i verificarea modelului"},"content":{"rendered":"<p class=\"wp-block-paragraph\">Alegerea unui transformator de curent \u00eencepe de la cerin\u021bele de m\u0103surare, nu doar de la num\u0103rul modelului. \u00cenainte de a plasa comanda, cump\u0103r\u0103torii trebuie s\u0103 defineasc\u0103 caracteristicile fizice, cerin\u021bele privind curentul primar, ie\u0219irea secundar\u0103, raportul de transformare, compatibilitatea cu loca\u021bia de instalare, cerin\u021bele de precizie, sarcina (dac\u0103 este cazul), frecven\u021ba, cerin\u021bele de izolare \u0219i documenta\u021bia exact\u0103 necesar\u0103.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Acest ghid de selec\u021bie a transformatoarelor de curent face distinc\u021bia \u00eentre pa\u0219ii generali de verificare \u0219i datele publicate referitoare la produsele RITOKS. Acesta nu calculeaz\u0103 raportul de transformare, sarcina sau set\u0103rile de protec\u021bie \u0219i nu \u00eenlocuie\u0219te consultan\u021ba tehnic\u0103 specific\u0103 aplica\u021biei sau documenta\u021bia referitoare la modelul exact.<\/p>\n\n\n\n<figure data-spectra-id=\"spectra-61d7b179-40b3-450d-9699-0734150a4dfc\" class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" height=\"2048\" width=\"2048\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/08\/\u751f\u6210\u4ea7\u54c1\u767d\u5e95\u56fe-1.png\" alt=\"Transformator de curent cu miez divizat din seria DP pentru monitorizarea aliment\u0103rii cu energie electric\u0103 \u00een mediul industrial\" class=\"wp-image-413\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/08\/\u751f\u6210\u4ea7\u54c1\u767d\u5e95\u56fe-1.png 2048w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/08\/\u751f\u6210\u4ea7\u54c1\u767d\u5e95\u56fe-1-300x300.png 300w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/08\/\u751f\u6210\u4ea7\u54c1\u767d\u5e95\u56fe-1-100x100.png 100w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/08\/\u751f\u6210\u4ea7\u54c1\u767d\u5e95\u56fe-1-600x600.png 600w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/08\/\u751f\u6210\u4ea7\u54c1\u767d\u5e95\u56fe-1-1024x1024.png 1024w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/08\/\u751f\u6210\u4ea7\u54c1\u767d\u5e95\u56fe-1-150x150.png 150w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/08\/\u751f\u6210\u4ea7\u54c1\u767d\u5e95\u56fe-1-768x768.png 768w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/08\/\u751f\u6210\u4ea7\u54c1\u767d\u5e95\u56fe-1-1536x1536.png 1536w\" sizes=\"auto, (max-width: 2048px) 100vw, 2048px\" \/><figcaption class=\"wp-element-caption\">Representative DP Series split-core current transformer. Published output, burden, frequency, insulation and mechanical details must be confirmed for the exact model.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Ghid rapid pentru alegerea transformatoarelor de curent<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">O specifica\u021bie util\u0103 porne\u0219te de la cerin\u021bele aplica\u021biei, trece la construc\u021bia CT \u0219i la interfa\u021ba electric\u0103, apoi se \u00eencheie cu documenta\u021bia privind montarea fizic\u0103 \u0219i modelul exact. Terminologia general\u0103 este descris\u0103 \u00een materialele tehnice oficiale din <a href=\"https:\/\/www.se.com\/us\/en\/faqs\/FA335683\/\" target=\"_blank\" rel=\"noopener\">Schneider Electric<\/a>, acesta <a href=\"https:\/\/www.se.com\/us\/en\/download\/document\/Z207506\/\" target=\"_blank\" rel=\"noopener\">documenta\u021bia de instalare a transformatorului de curent cu miez divizat<\/a>, iar <a href=\"https:\/\/emea.socomec.com\/sites\/default\/files\/2024-11\/CURRENT-SENSORS-AND-TRANSFORMERS_SELECTION-GUIDE_2024-11_DCG0160201EN_EN_0.pdf\" target=\"_blank\" rel=\"noopener\">Ghid de selectare a senzorilor de curent \u0219i a transformatoarelor Socomec<\/a>. Aceste surse sus\u021bin doar concepte generale; evalu\u0103rile \u0219i recomand\u0103rile lor nu constituie specifica\u021bii ale produselor RITOKS.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Parametri de selec\u021bie a transformatorului de curent<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Date de selec\u021bie<\/th><th>Ce trebuie confirmat<\/th><\/tr><\/thead><tbody>\n<tr><td>Construc\u021bia CT<\/td><td>Construc\u021bie cu miez divizat, cu miez \u00eenchis sau miniatural\u0103, \u00een func\u021bie de cerin\u021bele instala\u021biei<\/td><\/tr>\n<tr><td>Cerin\u021ba privind curentul primar<\/td><td>Intervalul curent al proiectului \u0219i op\u021biunea privind curentul primar publicat\u0103 pentru modelul respectiv<\/td><\/tr>\n<tr><td>Ie\u0219ire secundar\u0103<\/td><td>Date de intrare necesare pentru contorul sau dispozitivul de monitorizare conectat<\/td><\/tr>\n<tr><td>Raport<\/td><td>Rela\u021bia publicat\u0103 \u00eentre variabilele primare \u0219i secundare pentru modelul exact<\/td><\/tr>\n<tr><td>Potrivirea dintre conductor \u0219i orificiu<\/td><td>Dimensiunile conductorului sau ale barei colectoare \u00een raport cu deschiderea publicat\u0103<\/td><\/tr>\n<tr><td>Acces la instala\u021bie<\/td><td>Dac\u0103 conductorul poate fi deconectat sau trebuie s\u0103 r\u0103m\u00e2n\u0103 la locul s\u0103u<\/td><\/tr>\n<tr><td>Montare<\/td><td>Spa\u021biul disponibil, metoda de montare \u0219i cerin\u021bele privind cablurile<\/td><\/tr>\n<tr><td>Frecven\u021b\u0103<\/td><td>Frecven\u021ba de func\u021bionare necesar\u0103 \u0219i publicarea modelului exact<\/td><\/tr>\n<tr><td>Cerin\u021ba privind precizia<\/td><td>Terminologia necesar\u0103 \u0219i clasa sau domeniul de performan\u021b\u0103 exact(\u0103) publicat(\u0103)<\/td><\/tr>\n<tr><td>Povar\u0103<\/td><td>Cerin\u021ba VA aplicabil\u0103 \u0219i r\u00e2ndul exact \u00een care a fost publicat\u0103<\/td><\/tr>\n<tr><td>Izola\u021bie \/ rezisten\u021b\u0103<\/td><td>Cerin\u021bele proiectului \u0219i documenta\u021bia privind modelul exact<\/td><\/tr>\n<tr><td>Modelul exact<\/td><td>Configura\u021bie complet\u0103 a sufixelor, variantelor \u0219i ordinii<\/td><\/tr>\n<tr><td>Fi\u0219\u0103 tehnic\u0103 \/ documenta\u021bie<\/td><td>Documentele necesare privind instala\u021biile electrice, mecanice \u0219i conformitatea<\/td><\/tr>\n<\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">1. \u00cencepe\u021bi cu construc\u021bia CT<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Transformatoare de curent cu miez divizat<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Un transformator de curent cu miez divizat poate fi deschis pentru a fi instalat \u00een jurul unui conductor sau al unei bare colectoare existente. Acest aspect poate fi important \u00een cazul \u00een care deconectarea conductorului nu este posibil\u0103, \u00eens\u0103 construc\u021bia \u00een sine nu determin\u0103 raportul, puterea de ie\u0219ire, precizia sau sarcina necesare. Transformatorul <a href=\"https:\/\/ritoks.com\/ro\/products\/dp-series-split-core-current-transformer\/\">Transformator de curent cu miez divizat din seria DP<\/a> prezint\u0103 un exemplu de construc\u021bie RITOKS bazat pe nou\u0103 referin\u021be de modele publicate. Configura\u021bia complet\u0103 a ie\u0219irii secundare, sarcina, frecven\u021ba, izola\u021bia, deschiderea \u0219i dimensiunile detaliate nu sunt publicate \u0219i trebuie confirmate.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Transformatoare de curent cu miez \u00eenchis<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Un CT cu miez \u00eenchis necesit\u0103 ca conductorul s\u0103 treac\u0103 prin orificiul s\u0103u \u00een timpul instal\u0103rii. Prin urmare, cump\u0103r\u0103torii ar trebui s\u0103 verifice accesul pentru instalare, precum \u0219i specifica\u021biile electrice. <a href=\"https:\/\/ritoks.com\/ro\/products\/bh-0-66-60i-current-transformer-200-5a-1500-5a\/\">Transformator de curent de joas\u0103 tensiune BH-0.66 60I<\/a> este o familie cu un singur nucleu \u00eenchis, care cuprinde unsprezece r\u00e2nduri publicate cu raportul \/5A. Raportul exact, clasa de precizie \u0219i valorile de sarcin\u0103 ale acesteia trebuie interpretate \u00een ansamblu, f\u0103r\u0103 a fi recombinate \u00een mod arbitrar.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Transformatoare de curent miniaturale<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Termenul \u201eminiatural\u201d se refer\u0103 la dimensiunile reduse ale construc\u021biei; acesta nu reprezint\u0103 o afirma\u021bie privind o precizie superioar\u0103 sau o adecvare universal\u0103. Termenul <a href=\"https:\/\/ritoks.com\/ro\/products\/gta20l-precision-current-transformer-10a-100a\/\">Transformator de curent miniatural de precizie GTA20L<\/a> are un diametru exterior de 26 mm, o \u00een\u0103l\u021bime de 28,4 mm, o deschidere de 8,5 mm \u0219i cabluri de 200 mm. Aceste dimensiuni faciliteaz\u0103 verificarea potrivirii, \u00eens\u0103 c\u00e2mpurile sale electrice trebuie totu\u0219i adaptate la modelul exact.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">2. Determinarea cerin\u021bei de curent primar<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Stabili\u021bi cerin\u021bele privind curentul primar din proiect \u00eenainte de a selecta o familie de produse. Un interval de curent publicat arat\u0103 ce ofer\u0103 o familie de produse; acesta nu determin\u0103 modelul de care are nevoie sistemul. Referin\u021bele DP public\u0103 intervalele maxime ale raportului specificate de furnizori. R\u00e2ndurile BH-0.66 60I acoper\u0103 intervalul de la 200\/5A p\u00e2n\u0103 la 1500\/5A. Modelele GTA20L au o intrare de curent alternativ publicat\u0103 \u00eentre 10 \u0219i 100A. Acestea sunt structuri de date diferite ale produselor \u0219i nu trebuie tratate ca reguli de selec\u021bie interschimbabile.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">3. Confirma\u021bi ie\u0219irea secundar\u0103 \u0219i raportul<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Un raport CT descrie rela\u021bia dintre curentul primar \u0219i ie\u0219irea secundar\u0103 pentru un model specific de transformator. Mai \u00eent\u00e2i, defini\u021bi cerin\u021ba primar\u0103, identifica\u021bi ie\u0219irea secundar\u0103 necesar\u0103 pentru dispozitivul de m\u0103surare conectat, verifica\u021bi un raport publicat disponibil \u0219i apoi confirma\u021bi documenta\u021bia exact\u0103 a modelului. Aceast\u0103 secven\u021b\u0103 evit\u0103 presupunerea c\u0103 o nota\u021bie cunoscut\u0103 se aplic\u0103 tuturor familiilor de produse.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">BH-0.66 60I prezint\u0103 r\u00e2nduri explicite \/5A. GTA20L prezint\u0103 o ie\u0219ire de 20 mA CA \u0219i rapoarte de mapare cuprinse \u00eentre 500:1 \u0219i 5000:1 pentru cele opt modele ale sale. Seria DP nu prezint\u0103 o configura\u021bie complet\u0103 a ie\u0219irii pentru fiecare referin\u021b\u0103 listat\u0103. Prin urmare, o referin\u021b\u0103 de tip \/5A nu trebuie generalizat\u0103 la toate transformatoarele de curent RITOKS, iar modelul GTA20L nu trebuie prezentat ca un \u00eenlocuitor direct al unui transformator de tip \/5A.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">4. Verifica\u021bi deschiderea \u0219i spa\u021biul necesar pentru instalare<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Compara\u021bi dimensiunile conductorului sau ale barei colectoare cu deschiderea transformatorului de curent (CT), apoi verifica\u021bi spa\u021biul disponibil, accesul pentru instalare, metoda de montare \u0219i cerin\u021bele privind cablurile. Modelul GTA20L are o deschidere de 8,5 mm \u0219i dimensiuni compacte ale carcasei. Pentru seria DP sau modelul BH-0.66 60I nu sunt publicate pe paginile actuale valori comparabile privind deschiderea \u0219i dimensiunile, astfel \u00eenc\u00e2t aceste valori necesit\u0103 confirmarea modelului exact. Imaginile produsului nu constituie dovezi ale dimensiunilor.<\/p>\n\n\n\n<figure class=\"wp-block-gallery has-nested-images columns-2 is-cropped wp-block-gallery-1 is-layout-flex wp-block-gallery-is-layout-flex\">\n<figure data-spectra-id=\"spectra-8fc48c50-fd79-452a-ab6f-2a5fa4445e53\" class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" data-id=\"414\" height=\"800\" width=\"800\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/08\/O1CN01LE4QrA1LnbJIMx9HB_2218734541344-0-cib.jpg\" alt=\"Transformator de curent de joas\u0103 tensiune BH-0.66 60I\" class=\"wp-image-414\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/08\/O1CN01LE4QrA1LnbJIMx9HB_2218734541344-0-cib.jpg 800w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/08\/O1CN01LE4QrA1LnbJIMx9HB_2218734541344-0-cib-300x300.jpg 300w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/08\/O1CN01LE4QrA1LnbJIMx9HB_2218734541344-0-cib-100x100.jpg 100w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/08\/O1CN01LE4QrA1LnbJIMx9HB_2218734541344-0-cib-600x600.jpg 600w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/08\/O1CN01LE4QrA1LnbJIMx9HB_2218734541344-0-cib-150x150.jpg 150w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/08\/O1CN01LE4QrA1LnbJIMx9HB_2218734541344-0-cib-768x768.jpg 768w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><figcaption class=\"wp-element-caption\">Imagine reprezentativ\u0103 a familiei de produse BH-0.66 60I cu miez \u00eenchis.<\/figcaption><\/figure>\n\n\n<figure data-spectra-id=\"spectra-5f771cd3-8eba-4532-8511-bb463f18d8ed\" class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" data-id=\"417\" height=\"2048\" width=\"2048\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/08\/\u751f\u6210\u4ea7\u54c1\u767d\u5e95\u56fe-1-1.png\" alt=\"Transformator de curent miniatural de precizie GTA20L\" class=\"wp-image-417\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/08\/\u751f\u6210\u4ea7\u54c1\u767d\u5e95\u56fe-1-1.png 2048w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/08\/\u751f\u6210\u4ea7\u54c1\u767d\u5e95\u56fe-1-1-300x300.png 300w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/08\/\u751f\u6210\u4ea7\u54c1\u767d\u5e95\u56fe-1-1-100x100.png 100w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/08\/\u751f\u6210\u4ea7\u54c1\u767d\u5e95\u56fe-1-1-600x600.png 600w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/08\/\u751f\u6210\u4ea7\u54c1\u767d\u5e95\u56fe-1-1-1024x1024.png 1024w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/08\/\u751f\u6210\u4ea7\u54c1\u767d\u5e95\u56fe-1-1-150x150.png 150w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/08\/\u751f\u6210\u4ea7\u54c1\u767d\u5e95\u56fe-1-1-768x768.png 768w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/08\/\u751f\u6210\u4ea7\u54c1\u767d\u5e95\u56fe-1-1-1536x1536.png 1536w\" sizes=\"auto, (max-width: 2048px) 100vw, 2048px\" \/><figcaption class=\"wp-element-caption\">Imagine a produsului: transformator de curent miniatural GTA20L.<\/figcaption><\/figure>\n<\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">5. Verificarea cerin\u021belor privind acurate\u021bea<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Precizia este o cerin\u021b\u0103 care trebuie definit\u0103 \u0219i verificat\u0103, nu un simplu criteriu de clasificare a calit\u0103\u021bii. Paginile din seria DP men\u021bioneaz\u0103 clasa 0,5 numai \u00een cazul \u00een care aceasta este publicat\u0103 \u00een mod explicit. R\u00e2ndurile BH-0.66 60I includ clasele publicate 1.0, 0.5, 0.5S, 0.2 \u0219i 0.2S, dar disponibilitatea depinde de r\u00e2ndul exact. GTA20L utilizeaz\u0103 terminologia publicat\u0103 privind eroarea de faz\u0103 \u0219i liniaritatea, \u00een loc de acela\u0219i tabel de clase. Nicio clas\u0103 nu trebuie selectat\u0103 automat sau utilizat\u0103 pentru a deduce adecvarea \u00een ceea ce prive\u0219te facturarea, contorizarea veniturilor sau protec\u021bia.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">6. Verifica\u021bi sursa \u00een locul \u00een care a fost publicat\u0103<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Sarcina este o specifica\u021bie CT care ar putea necesita verificarea \u00een raport cu circuitul de m\u0103surare conectat, acolo unde este specificat\u0103. BH-0.66 60I public\u0103 valori de 2,5 VA pentru r\u00e2ndurile 200\/5A \u0219i 250\/5A la clasele afi\u0219ate 1,0 \u0219i 0,5, intr\u0103ri de 5 VA \u00een r\u00e2ndurile exacte publicate de la 300\/5A p\u00e2n\u0103 la 600\/5A \u0219i intr\u0103ri de 10 VA \u00een r\u00e2ndurile exacte publicate de la 750\/5A p\u00e2n\u0103 la 1500\/5A. Aceste valori trebuie s\u0103 r\u0103m\u00e2n\u0103 corelate cu r\u00e2ndurile surs\u0103. Sarcina nu este publicat\u0103 pentru DP, iar structura BH VA nu trebuie transferat\u0103 \u00een GTA20L.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">7. Confirma\u021bi datele privind frecven\u021ba \u0219i izola\u021bia<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Cerin\u021bele privind frecven\u021ba, izola\u021bia \u0219i rezisten\u021ba la tensiune trebuie incluse atunci c\u00e2nd este cazul. Modelul GTA20L prezint\u0103 o frecven\u021b\u0103 de 50\/60 Hz, o rezisten\u021b\u0103 de izola\u021bie mai mare de 1000 M\u03a9, o clas\u0103 de tensiune de 0,66\/0,72 kV \u0219i o rezisten\u021b\u0103 la tensiune de 4 kV \/ 50 Hz \/ 1 min. Aceste c\u00e2mpuri specifice modelului nu stabilesc date corespunz\u0103toare pentru DP sau BH-0,66 60I, ale c\u0103ror pagini actuale nu prezint\u0103 specifica\u021bii complete privind frecven\u021ba \u0219i izola\u021bia.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Gamele de transformatoare de curent RITOKS publicate<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Acest <a href=\"https:\/\/ritoks.com\/ro\/product-category\/electrical-measurement-monitoring\/current-transformers\/\">Categoria \u201eTransformatoare de curent\u201d<\/a> se afl\u0103 \u00een interiorul <a href=\"https:\/\/ritoks.com\/ro\/product-category\/electrical-measurement-monitoring\/\">M\u0103surarea \u0219i monitorizarea sistemelor electrice<\/a>. Prezentarea general\u0103 de mai jos este destinat\u0103 exclusiv evalu\u0103rii familiale. Pentru arhitecturi de m\u0103surare adiacente, dar neechivalente, compara\u021bi <a href=\"https:\/\/ritoks.com\/ro\/product-category\/electrical-measurement-monitoring\/rogowski-coils\/\">Bobine Rogowski<\/a> cum ar fi <a href=\"https:\/\/ritoks.com\/ro\/products\/zrc-flexible-rogowski-coils-600a-3000a\/\">Familia ZRC<\/a>, <a href=\"https:\/\/ritoks.com\/ro\/product-category\/electrical-measurement-monitoring\/hall-current-sensors\/\">Senzori de curent de hol<\/a> cum ar fi <a href=\"https:\/\/ritoks.com\/ro\/products\/hs2v-h02-open-loop-hall-current-sensors\/\">Familia HS2V H02<\/a>, \u0219i <a href=\"https:\/\/ritoks.com\/ro\/product-category\/electrical-measurement-monitoring\/dc-current-transducers\/\">Traductoare de curent continuu<\/a> cum ar fi <a href=\"https:\/\/ritoks.com\/ro\/products\/wbi334u01-s-dc-current-transducer-4-20ma\/\">WBI334U01-S<\/a>; principiile lor de func\u021bionare, semnalele de ie\u0219ire \u0219i cerin\u021bele de instalare nu sunt interschimbabile.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Prezentare general\u0103 a gamei de transformatoare de curent RITOKS (versiune publicat\u0103)<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Familie<\/th><th>Construc\u021bii<\/th><th>Informa\u021bii publicate privind studiile primare \/ indicatorii<\/th><th>Rezultate secundare publicate<\/th><th>Domenii de precizie \/ performan\u021b\u0103<\/th><th>Date tehnice<\/th><th>Date esen\u021biale care trebuie confirmate<\/th><\/tr><\/thead><tbody>\n<tr><td>Seria DP<\/td><td>Miez divizat<\/td><td>Nou\u0103 referin\u021be cu intervale de raport maxim specificate de furnizor<\/td><td>Configura\u021bia complet\u0103 nu a fost publicat\u0103<\/td><td>Clasa 0,5 numai \u00een cazul \u00een care este men\u021bionat\u0103 \u00een mod explicit<\/td><td>Nepublicat<\/td><td>Putere de ie\u0219ire, sarcin\u0103, frecven\u021b\u0103, izola\u021bie, deschidere, dimensiuni, montare \u0219i documente<\/td><\/tr>\n<tr><td>BH-0.66 60I<\/td><td>Cu miez \u00eenchis, de joas\u0103 tensiune, cu un singur conductor<\/td><td>Unsprezece r\u00e2nduri, de la 200\/5A la 1500\/5A<\/td><td>5A \u00een r\u00e2nduri exacte, a\u0219a cum au fost publicate<\/td><td>Coresponden\u021be exacte \u00eentre r\u00e2nduri pentru clasa \u0219i valorile 2,5 VA, 5 VA sau 10 VA<\/td><td>Nepublicat<\/td><td>Dimensiuni, frecven\u021b\u0103, izola\u021bie, montare \u0219i documente<\/td><\/tr>\n<tr><td>GTA20L<\/td><td>Miniatur\u0103<\/td><td>Opt modele; intrare CA de 10\u2013100 A; rapoarte de mapare de la 500:1 la 5000:1<\/td><td>20 mA c.a.<\/td><td>Eroarea de faz\u0103 a modelului exact, liniaritatea, rezisten\u021ba \u0219i domeniile de liniaritate<\/td><td>Corp de 26 \u00d7 28,4 mm, deschidere de 8,5 mm, cabluri de 200 mm<\/td><td>Modelul exact, compatibilitatea cu dispozitivele conectate \u0219i documenta\u021bia necesar\u0103<\/td><\/tr>\n<\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">8. Fluxul de lucru pentru verificarea modelului exact<\/h2>\n\n\n\n<figure data-spectra-id=\"spectra-27b6357a-52a2-44fa-9dbe-9968726d2a67\" class=\"wp-block-image size-full\"><a href=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/current-transformer-selection-workflow.jpg\"><img loading=\"lazy\" decoding=\"async\" height=\"943\" width=\"900\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/current-transformer-selection-workflow.jpg\" alt=\"Fluxul de lucru pentru verificarea transformatorilor de curent, de la cerin\u021bele aplica\u021biei p\u00e2n\u0103 la determinarea raportului de transformare \u0219i confirmarea modelului exact\" class=\"wp-image-790\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/current-transformer-selection-workflow.jpg 900w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/current-transformer-selection-workflow-600x629.jpg 600w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/current-transformer-selection-workflow-286x300.jpg 286w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/current-transformer-selection-workflow-768x805.jpg 768w\" sizes=\"auto, (max-width: 900px) 100vw, 900px\" \/><\/a><figcaption class=\"wp-element-caption\">Flux de lucru conceptual pentru definirea cerin\u021belor privind transformatoarele de curent \u0219i verificarea construc\u021biei, a curentului primar, a ie\u0219irii secundare, a raportului de transformare, a compatibilit\u0103\u021bii mecanice, a preciziei, a sarcinii \u0219i a datelor tehnice exacte \u00eenainte de confirmarea modelului \u0219i de solicitarea ofertei. Nu este o metod\u0103 de dimensionare sau de calcul a transformatoarelor de curent.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">9. Informa\u021bii care trebuie incluse \u00eentr-o cerere de ofert\u0103 pentru transformatoare de curent<\/h2>\n\n\n\n<ul class=\"wp-block-list\"><li>Cerin\u021be privind aplicarea \u0219i m\u0103surarea<\/li><li>Construc\u021bia necesar\u0103 a tomografiei computerizate<\/li><li>Cerin\u021ba privind curentul primar<\/li><li>Puterea secundar\u0103 necesar\u0103 \u0219i raportul de transmisie, dac\u0103 sunt cunoscute<\/li><li>Dimensiunile conductorului sau ale barei colectoare \u0219i dimensiunea deschiderii necesare<\/li><li>Cerin\u021be privind accesul la locul de instalare \u0219i montare<\/li><li>Cerin\u021be privind acurate\u021bea \u0219i sarcina administrativ\u0103, dac\u0103 este cazul<\/li><li>Cerin\u021be privind frecven\u021ba \u0219i izola\u021bia sau rezisten\u021ba la tensiune<\/li><li>Cantitate \u0219i destina\u021bie<\/li><li>Fi\u0219a tehnic\u0103, schi\u021ba \u0219i alte documente necesare<\/li><\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">10. Ce date mai necesit\u0103 confirmarea prin modelul exact?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Confirmarea la nivel de model este esen\u021bial\u0103 \u00een toate cazurile \u00een care o pagin\u0103 nu prezint\u0103 o configura\u021bie complet\u0103 a ie\u0219irii, diafragma, dimensiunile, metoda de montare, sarcina, frecven\u021ba, c\u00e2mpul de izola\u021bie sau documenta\u021bia de \u00eenso\u021bire. Absen\u021ba unui c\u00e2mp nu constituie o dovad\u0103 c\u0103 cerin\u021ba respectiv\u0103 nu este important\u0103 sau c\u0103 se aplic\u0103 valoarea unei alte familii de produse. Solicita\u021bi modelul exact disponibil la comand\u0103 \u0219i documenta\u021bia necesar\u0103 pentru proiectul dumneavoastr\u0103.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">CT Direction and Placement: Reviewing Unexpected Readings<\/h2>\n<p class=\"wp-block-paragraph\">When a monitoring system reports a negative value, zero current or a result that does not match another meter, first establish whether the reading is actually unexpected. Negative active power can indicate genuine export under the meter\u2019s sign convention. Confirm the operating power flow before treating a negative reading as a wiring fault.<\/p>\n<p class=\"wp-block-paragraph\">The same symptom can come from different causes: CT orientation, the wrong conductor or branch, phase mismatch, an incorrect ratio, or a software setting. Use the symptom to guide document and configuration review.<\/p>\n<h3 class=\"wp-block-heading\">Symptoms and records to review<\/h3>\n<figure class=\"wp-block-table\"><table><thead><tr><th>Observed symptom<\/th><th>Possible causes to consider<\/th><th>First non-invasive check<\/th><\/tr><\/thead><tbody><tr><td>Import and export appear reversed<\/td><td>Actual export, CT orientation, sign convention or measurement location<\/td><td>Compare operating power flow with the CT and meter documentation<\/td><\/tr><tr><td>Reading is close to zero during a load<\/td><td>For ordinary load measurement, opposing conductor currents can cancel; the wrong branch or an unclosed core can also be involved<\/td><td>Review drawings and commissioning photos; ask the installer to verify conductor routing<\/td><\/tr><tr><td>One phase differs<\/td><td>CT phase does not match the voltage reference or phase order<\/td><td>Compare phase labels and CT input channels<\/td><\/tr><tr><td>Value is consistently high or low<\/td><td>Ratio, scaling, unit or secondary-output setting<\/td><td>Compare the exact CT model and ratio with the meter configuration<\/td><\/tr><tr><td>Value changes sign between modes<\/td><td>Actual import\/export reversal, source\/load position or monitoring profile<\/td><td>Check real power flow first, then the documented sign convention<\/td><\/tr><\/tbody><\/table><\/figure>\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/docs.openenergymonitor.org\/electricity-monitoring\/ct-sensors\/installation.html\" target=\"_blank\" rel=\"noopener\">OpenEnergyMonitor\u2019s installation guidance<\/a> explains why a CT around multiple conductors can read their vector sum and why polarity affects real-power sign. Its single-conductor guidance applies to ordinary load measurement; dedicated residual-current or summation schemes require their own design instructions.<\/p>\n<h3 class=\"wp-block-heading\">Define the measurement boundary<\/h3>\n<p class=\"wp-block-paragraph\">A CT at a grid connection, between an inverter and a distribution board, or on a load branch answers a different question. A correct arrow cannot compensate for a CT installed at the wrong system boundary. Record the target, physical location, monitored conductor, positive direction, voltage reference and monitoring mode.<\/p>\n<h3 class=\"wp-block-heading\">Read the documented polarity convention<\/h3>\n<p class=\"wp-block-paragraph\">CTs may use an arrow, P1\/P2, H1\/H2, K\/L, a dot or another mark. The meaning must come from the CT or meter documentation. Follow this order: identify the exact CT and receiving device; read the positive-flow definition; compare the mark; check the voltage-reference phase and input channel; then check ratio, scale and mode.<\/p>\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.se.com\/au\/en\/faqs\/FA203850\/\" target=\"_blank\" rel=\"noopener\">Schneider\u2019s CT orientation guidance<\/a> covers polarity marks and limits installation and maintenance to qualified personnel. Use records and configuration screenshots for this review.<\/p>\n<h3 class=\"wp-block-heading\">Prepare the support request<\/h3>\n<ul class=\"wp-block-list\"><li>Exact CT model and complete suffix<\/li><li>Polarity marking, ratio and secondary output<\/li><li>Monitored conductor, phase and physical location<\/li><li>Receiving input type, ratio, scale factor and unit<\/li><li>Voltage-reference channel and monitoring mode<\/li><li>Timestamped screenshots, operating condition and installation records<\/li><\/ul>\n<h3 class=\"wp-block-heading\">Refer physical changes to qualified personnel<\/h3>\n<p class=\"wp-block-paragraph\">Stop at the document and software-review stage when the CT is inside a live distribution board, the CT type or secondary circuit is unknown, the conductor cannot be identified, or the proposed fix requires disconnecting leads or moving the sensor. A current-output CT with an open secondary can develop hazardous voltage while primary current is flowing. The exact CT construction and manufacturer\u2019s procedure must be checked by qualified personnel before physical changes.<\/p><h2 class=\"wp-block-heading\">\u00centreb\u0103ri frecvente<\/h2>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Ce informa\u021bii sunt necesare pentru alegerea unui transformator de curent?<\/summary><p class=\"wp-block-paragraph\">Se vor specifica aplica\u021bia, construc\u021bia, curentul primar, puterea secundar\u0103 necesar\u0103, raportul de transformare, compatibilitatea fizic\u0103, accesul pentru instalare, precizia, sarcina (dac\u0103 este cazul), frecven\u021ba, cerin\u021bele de izola\u021bie \u0219i documenta\u021bia necesar\u0103 privind modelul exact.<\/p><\/details>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Care este diferen\u021ba dintre structura CT cu miez divizat \u0219i cea cu miez \u00eenchis?<\/summary><p class=\"wp-block-paragraph\">Un transformator de curent cu miez despicat se monteaz\u0103 \u00een jurul unui conductor sau al unei bare colectoare existente. Un transformator de curent cu miez \u00eenchis necesit\u0103 ca conductorul s\u0103 treac\u0103 prin orificiul s\u0103u. Niciuna dintre aceste construc\u021bii, luat\u0103 separat, nu determin\u0103 performan\u021ba electric\u0103 sau adecvarea pentru o anumit\u0103 aplica\u021bie.<\/p><\/details>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Pot selecta un CT doar pe baza curentului primar?<\/summary><p class=\"wp-block-paragraph\">Nu. De asemenea, trebuie confirmate ie\u0219irea secundar\u0103, raportul de transmisie, compatibilitatea cu dispozitivele conectate, potrivirea fizic\u0103, precizia \u0219i alte cerin\u021be ale proiectului.<\/p><\/details>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>De ce trebuie verificate tensiunea de ie\u0219ire secundar\u0103 \u0219i raportul transformatorului de curent?<\/summary><p class=\"wp-block-paragraph\">Familiile RITOKS ofer\u0103 diferite formate de ie\u0219ire. Modelul BH-0.66 60I utilizeaz\u0103 r\u00e2nduri explicite \/5A, modelul GTA20L ofer\u0103 o ie\u0219ire de 20 mA c.a., iar seria DP nu ofer\u0103 toate configura\u021biile complete de ie\u0219ire.<\/p><\/details>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Aceea\u0219i clas\u0103 de precizie este disponibil\u0103 pentru toate aparatele RITOKS CT?<\/summary><p class=\"wp-block-paragraph\">Nu. Termenii referitori la precizie sau performan\u021b\u0103 sunt specifici fiec\u0103rei familii \u0219i fiec\u0103rui model. Consulta\u021bi documenta\u021bia exact\u0103 publicat\u0103 pentru fiecare serie sau model.<\/p><\/details>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Sunt publicate valorile sarcinii pentru fiecare transformator de curent RITOKS?<\/summary><p class=\"wp-block-paragraph\">Nu. Valorile exacte ale VA sunt publicate pentru anumite r\u00e2nduri BH-0.66 60I. Sarcina nu este publicat\u0103 pentru seria DP, iar pentru modelul GTA20L nu trebuie presupus\u0103 aceea\u0219i structur\u0103.<\/p><\/details>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Ce informa\u021bii trebuie s\u0103 furnizez atunci c\u00e2nd solicit un model CT exact?<\/summary><p class=\"wp-block-paragraph\">Preciza\u021bi cerin\u021bele electrice \u0219i mecanice, puterea de ie\u0219ire \u0219i raportul de transmisie necesare, detaliile de instalare, cantitatea, destina\u021bia, precum \u0219i fi\u0219a tehnic\u0103 sau desenele necesare pentru verificare.<\/p><\/details>\n\n\n\n<div class=\"wp-block-group has-base-color has-contrast-background-color has-text-color has-background is-layout-constrained wp-block-group-is-layout-constrained\">\n<h2 class=\"wp-block-heading\">Alege\u021bi transformatorul de curent potrivit pentru proiectul dumneavoastr\u0103<\/h2>\n\n\n<p class=\"wp-block-paragraph\">Trimite\u021bi companiei RITOKS cererea dumneavoastr\u0103, \u00eempreun\u0103 cu cerin\u021bele privind debitul, randamentul, raportul, compatibilitatea fizic\u0103 \u0219i documenta\u021bia necesar\u0103 pentru evaluarea modelului exact.<\/p>\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/ritoks.com\/ro\/contact-us\/\">Contacta\u021bi RITOKS pentru o cerere de ofert\u0103<\/a><\/div>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Selecting a current transformer starts with the measurement requirement, not with a model number alone. Buyers should define the physical [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":1427,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ritoks_resource_detail_renderer":null,"ritoks_resource_product_cat_term_id":0,"footnotes":""},"categories":[68],"tags":[],"class_list":["post-789","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-electrical-measurement-monitoring"],"acf":[],"spectra_blocks_featured_image_url":{"thumbnail":{"url":"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/current-transformer-hero-150x150.webp","width":150,"height":150},"medium":{"url":"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/current-transformer-hero-300x169.webp","width":300,"height":169},"medium_large":{"url":"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/current-transformer-hero-768x432.webp","width":768,"height":432},"large":{"url":"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/current-transformer-hero-1024x576.webp","width":1024,"height":576},"full":{"url":"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/current-transformer-hero.webp","width":1672,"height":941}},"spectra_blocks_author_info":{"display_name":"RITOKS","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/6d7d0fc73468198f994ab13ef6eb6558c53b6ed1ad86364d5165efe8bdf8eb4a?s=96&d=mm&r=g","author_link":"https:\/\/ritoks.com\/ro\/author\/dazzlingwqbgmail-com\/","description":""},"_links":{"self":[{"href":"https:\/\/ritoks.com\/ro\/wp-json\/wp\/v2\/posts\/789","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ritoks.com\/ro\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ritoks.com\/ro\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ritoks.com\/ro\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/ritoks.com\/ro\/wp-json\/wp\/v2\/comments?post=789"}],"version-history":[{"count":4,"href":"https:\/\/ritoks.com\/ro\/wp-json\/wp\/v2\/posts\/789\/revisions"}],"predecessor-version":[{"id":2407,"href":"https:\/\/ritoks.com\/ro\/wp-json\/wp\/v2\/posts\/789\/revisions\/2407"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ritoks.com\/ro\/wp-json\/wp\/v2\/media\/1427"}],"wp:attachment":[{"href":"https:\/\/ritoks.com\/ro\/wp-json\/wp\/v2\/media?parent=789"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ritoks.com\/ro\/wp-json\/wp\/v2\/categories?post=789"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ritoks.com\/ro\/wp-json\/wp\/v2\/tags?post=789"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}