AC Surge Protective Devices for Low-Voltage Systems · Comparison
Type 1 vs Type 2 AC SPD: Installation-Point Questions
“Type 1 or Type 2?” is not answered by choosing the larger number on a product page. The installation point, lightning exposure, distribution topology and applicable design requirements determine which surge protective device (SPD) duty is needed. Type 1 devices are associated with lightning-current duties at suitable entrance locations; Type 2 devices are commonly applied to downstream distribution and indirect-surge or switching-transient protection. A combined Type 1+2 product can cover both tested roles when the exact model and installation support them. None of these labels alone is a complete protection design.

RITOKS publishes a GSP10-C40N typ 2 SPD för växelström and an AC SPD category. That published Type 2 product should not be relabelled Type 1 because it is mounted near a service entrance. This article helps buyers ask the right installation-point questions and identify when an additional verified product class or engineer review is required.
Start With the Building and the One-Line
The first question is where the conductors enter the building and how the electrical distribution branches to subboards and equipment. Mark the service or main distribution point, any external lightning-protection system, relevant incoming lines, downstream panels and sensitive equipment. Ask the electrical designer which installation rules and lightning-protection concept apply to the project. A blog post cannot determine a mandatory SPD type from a photograph of a switchboard.
DEHN's surge-protection overview describes Type 1 devices at the building entrance for lightning equipotential bonding and Type 2 devices commonly in sub-distribution boards. That is a useful conceptual map, not a universal rule that every entrance needs one specific product. The actual need and location depend on the site's external lightning protection, supply characteristics, risk assessment and local requirements.
The approved one-line should state what each SPD position is intended to protect and what conductors it connects to. Without that drawing, an RFQ asking for “one Type 2 40 kA SPD” may be missing a required entrance duty, the correct topology, or a downstream coordinated stage. Ask for the design premise before shopping by type label.
What Type 1 Signifies
Type 1 is associated with a lightning-current test duty and is generally considered at points where lightning current may enter the low-voltage installation under the applicable protection concept. A manufacturer will identify the exact device's Type 1 classification and its impulse-current rating, commonly designated Iimp. The label does not mean the device can be installed in any earthing system or that one module protects every conductor path.
A Type 1 SPD also has other application data: maximum continuous operating voltage, voltage protection level, connection topology, short-circuit and follow-current behavior where relevant, and installation instructions. The electrical designer must confirm those parameters against the system. A device tested for Type 1 duty may also be labelled Type 1+2 if it has the relevant second classification; do not infer this from appearance or from the word “lightning” in a brochure.
IEC 61643-11:2025 is the current IEC product standard covering AC low-voltage SPDs within its stated scope, including test and rating requirements. It does not certify an unlisted RITOKS Type 1 product or decide a building's required placement. Ask for the exact manufacturer's classification document and the local design basis.
What Type 2 Signifies
Type 2 SPDs are commonly used in distribution boards to limit transient overvoltages from indirect lightning effects and switching events. Manufacturer data will identify Type 2 classification and relevant discharge-current information, typically including nominal and maximum discharge-current designations such as In and Imax, along with Uc and Up. The meaning of each number depends on the specified test and circuit configuration. “40 kA” without its designation is not enough.
Den RITOKS Type 2 AC SPD selection guide discusses exact-system topology, Uc, In, Imax, Up and upstream protection for the published family. This article deliberately addresses where a Type 1 or Type 2 duty belongs in a site protection concept; it is not a duplicate parameter-selection guide. The GSP10-C40N page is a Type 2 product reference only within its published variants.
A Type 2 device located in the main board remains a Type 2 device. Moving it upstream does not give it Type 1 impulse-current capability. Conversely, a Type 1 label does not remove the need to examine the protection level at downstream equipment or to coordinate multiple stages where required.
Installation Point and Lightning-Protection Zones
The lightning-protection-zone concept helps explain why different SPD duties may be needed at different boundaries. Incoming conductors can bring substantial lightning current toward the installation; internal distribution stages can see different surge conditions. Phoenix Contact's surge-protection basics describes SPD types in relation to zone transitions and coordinated protection. Treat it as technical background, not a device-placement recipe for every site.
In the RFQ, provide a one-line with location labels rather than a detached parts list. State whether the position is a service entrance, main distribution, sub-distribution or equipment-adjacent board. Record whether the building has external lightning protection and what the design engineer has specified. The supplier can then return a product matching the requested duty and identify missing information.

Coordination between SPD stages matters. A Type 2 downstream from a Type 1 is not automatically coordinated because both devices are from the same brand or mounted in different panels. Ask for manufacturer application guidance covering their separation, energy coordination and protection level at the protected equipment. Do not invent a universal cable length or distance; the exact design and manufacturer's instructions govern.
Earthing and Connection Topology
An SPD's pole count and connection arrangement must match the electrical system. A nominally similar three-phase board may use a different earthing configuration or neutral treatment. The exact topology can affect Uc selection, protective modes and the components required. Never use a generic “four-pole SPD” photo as proof that the proposed device fits the site.
Ask the designer for system voltage, phase and earthing arrangement at each intended SPD location. Then ask the supplier to identify the exact variant and wiring topology in its documentation. Do not transfer the RITOKS Type 2 model's published Uc or topology information to a hypothetical Type 1 product. The AC SPD family and the DC SPD category are also separate; AC and PV DC protection data should not be mixed.
The installer should follow the exact manufacturer's wiring and conductor-length instructions. This article does not prescribe a connection diagram, conductor size or backup-protection device. Those choices are part of the approved electrical design and local code compliance.
Upstream Protection and Short-Circuit Data
SPDs can require specified upstream overcurrent protection and have documented short-circuit behavior. That requirement is distinct from the surge classification. A Type 1 or Type 2 number does not identify which breaker or fuse can serve as backup protection. Obtain the exact SPD installation manual, permitted protective-device range and prospective short-circuit current at the connection point.
RITOKS also publishes AC miniature circuit breakers, but a separate breaker listing is not evidence of a tested pairing with the GSP10-C40N. In this Type 1/Type 2 decision, keep the roles separate: surge duty, fault-interruption duty and coordination are distinct fields in the submittal.
If the manufacturer documentation does not identify a suitable backup arrangement for the intended system, mark the SPD selection pending. Do not size an upstream protective device from Iimp, In or Imax by numerical analogy. Surge-current values and fault-current interruption values represent different tests.
A Two-Location RFQ Worksheet
| Fråga | Entrance/main board | Downstream board |
|---|---|---|
| Required SPD duty | Type 1, Type 1+2 or engineer-defined | Type 2 or engineer-defined |
| Lightning exposure basis | Building/site design record | Upstream protection context |
| Systemtopologi | Voltage, phases, earthing | Voltage, phases, earthing |
| Exact SPD data | Iimp if Type 1; Uc, Up and other ratings | In/Imax if Type 2; Uc, Up and other ratings |
| Fault/backup details | Tillverkarens anvisningar | Tillverkarens anvisningar |
| Samordning | With downstream stages | With upstream stages and equipment |

This worksheet is a request for evidence, not a default bill of materials. Some projects may use a combined product at an entrance; others need separate stages; others have different local requirements. A buyer should have the engineer state the protection concept and let suppliers quote against the same document.
Ask bidders to identify exact model codes, connection topology, test classification and supporting documents for each location. Require a deviation list if they propose a Type 2-only unit where the design requests Type 1 duty, or if they substitute an integrated Type 1+2 device for two stages. Such substitutions require designer review; a brochure headline cannot authorize them.
Avoid Classification Shortcuts
Do not equate a high Imax on a Type 2 SPD with a Type 1 impulse rating. Do not assume that the words “lightning protection” prove Type 1 classification. Do not treat a Type 1 SPD as automatically sufficient for sensitive equipment at a remote downstream panel. Each conclusion requires the relevant tested characteristic and the system-level coordination design.
Similarly, do not use a DC PV SPD in an AC distribution board because both mention the same surge-current unit. The voltage, connection and test context differ. Do not state that every main board needs a particular four-pole unit without knowing the earthing system. Where the project information is incomplete, the safest procurement output is a clearly marked technical query.
Closing Decision
Type 1 versus Type 2 is principally an installation-duty and system-design question. Mark the SPD positions on the one-line, document lightning exposure and topology, then require the exact product classification and rating set for each position. RITOKS's published Type 2 AC SPD may suit a documented Type 2 requirement after exact-model review; it should not be promoted as Type 1 by location or marketing language. The final arrangement belongs to the qualified electrical designer and the manufacturer's installation evidence.