{"id":699,"date":"2026-09-05T16:51:06","date_gmt":"2026-09-05T16:51:06","guid":{"rendered":"https:\/\/ritoks.com\/?p=699"},"modified":"2026-09-20T06:54:43","modified_gmt":"2026-09-20T06:54:43","slug":"b-curve-vs-c-curve-vs-d-curve-mcb","status":"publish","type":"post","link":"https:\/\/ritoks.com\/sv\/b-curve-vs-c-curve-vs-d-curve-mcb\/","title":{"rendered":"MCB-brytare med B-kurva, C-kurva och D-kurva: Vad \u00e4r skillnaden?"},"content":{"rendered":"<div class=\"wp-block-group alignfull has-ast-global-color-5-color has-ast-global-color-2-background-color has-text-color has-background is-layout-constrained wp-container-core-group-is-layout-a2d0cf3a wp-block-group-is-layout-constrained\" style=\"padding-top:64px;padding-right:24px;padding-bottom:64px;padding-left:24px\">\n\n\n<h1 class=\"wp-block-heading\">MCB-brytare med B-kurva, C-kurva och D-kurva: Vad \u00e4r skillnaden?<\/h1>\n\n\n\n<figure data-spectra-id=\"spectra-f74f02a5-f033-46d2-84e4-03da4e4b713c\" class=\"wp-block-image aligncenter size-full has-custom-border\" ><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-family-hero.png\" alt=\"Exempel p\u00e5 olika serier av AC-miniatyrbrytare i en industriell elverkstad\" class=\"wp-image-701\"  width=\"1672\" height=\"941\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-family-hero.png 1672w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-family-hero-600x338.png 600w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-family-hero-300x169.png 300w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-family-hero-1024x576.png 1024w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-family-hero-768x432.png 768w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-family-hero-1536x864.png 1536w\" sizes=\"auto, (max-width: 1672px) 100vw, 1672px\" \/><figcaption class=\"wp-element-caption\">Exempel p\u00e5 vanliga AC-MCB-typer i en industriell elmilj\u00f6.<\/figcaption><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Kurvorna B, C och D \u00e4r olika utl\u00f6sningskarakt\u00e4ristiker som anv\u00e4nds vid <a href=\"https:\/\/ritoks.com\/sv\/product-category\/ac-power-protection\/miniature-circuit-breakers\/\">miniatyrstr\u00f6mavbrytare (MCB)<\/a>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Bokst\u00e4verna anger inte den aktuella m\u00e4rkstr\u00f6mmen, brytkapaciteten eller antalet poler. Ist\u00e4llet anv\u00e4nds de f\u00f6r att beskriva hur brytaren reagerar p\u00e5 h\u00f6gre kortvarig str\u00f6m inom sitt omr\u00e5de f\u00f6r omedelbar utl\u00f6sning.<\/p>\n\n\n<\/div>\n\n\n\n<div class=\"wp-block-group alignfull is-layout-constrained wp-container-core-group-is-layout-105ba9aa wp-block-group-is-layout-constrained\" style=\"padding-top:64px;padding-right:24px;padding-bottom:64px;padding-left:24px\">\n\n\n<p class=\"wp-block-paragraph\">I tillverkarens tekniska data anges vanligtvis f\u00f6ljande karakteristiska intervall:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>B-kurva: cirka 3\u20135 \u00d7 In<\/li>\n<li>C-kurva: cirka 5\u201310 \u00d7 In<\/li>\n<li>D-kurva: cirka 10\u201320 \u00d7 In<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">H\u00e4r st\u00e5r In f\u00f6r brytarens m\u00e4rkstr\u00f6m f\u00f6r den karakt\u00e4ristik som avses. <a href=\"https:\/\/www.eaton.com\/content\/dam\/eaton\/support\/apac-support-assets\/japan-cps-assets\/products\/2023promotions_lp\/sccr2024_pdf01.pdf\" target=\"_blank\" rel=\"noopener\">Eatons tekniska dokumentation<\/a> publicerar samma kortslutningsutl\u00f6sningsintervall B, C och D f\u00f6r sina serier av miniatyrbrytare.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Den praktiska skillnaden \u00e4r att de tre kurvorna t\u00e5l olika niv\u00e5er av kortvarig str\u00f6m innan de n\u00e5r omr\u00e5det f\u00f6r omedelbar utl\u00f6sning.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Det betyder inte att en kurva generellt sett \u00e4r b\u00e4ttre \u00e4n en annan.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Den erforderliga kurvan b\u00f6r baseras p\u00e5 den faktiska elektriska konstruktionen, f\u00f6rv\u00e4ntade startstr\u00f6msf\u00f6rh\u00e5llanden och dokumentationen f\u00f6r den brytare som v\u00e4ljs.<\/p>\n\n\n\n<h2 id=\"in-this-guide\" class=\"wp-block-heading\">I den h\u00e4r guiden<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"#quick-comparison\">Snabbj\u00e4mf\u00f6relse: B-kurva vs C-kurva vs D-kurva<\/a><\/li>\n<li><a href=\"#mcb-trip-curve\">Vad \u00e4r en MCB-utl\u00f6sningskurva?<\/a><\/li>\n<li><a href=\"#b-curve\">Vad \u00e4r en B-kurva-MCB?<\/a><\/li>\n<li><a href=\"#c-curve\">Vad \u00e4r en C-kurv-MCB?<\/a><\/li>\n<li><a href=\"#d-curve\">Vad \u00e4r en D-kurvformad jordfelsbrytare (MCB)?<\/a><\/li>\n<li><a href=\"#curve-availability\">Aktuell tillg\u00e4nglighet f\u00f6r RITOKS-kurvor<\/a><\/li>\n<li><a href=\"#selection-process\">Hur man v\u00e4ljer mellan alternativ med B-, C- och D-kurvor<\/a><\/li>\n<li><a href=\"#frequently-asked-questions\">Vanliga fr\u00e5gor<\/a><\/li>\n<\/ul>\n\n\n\n<h2 id=\"quick-comparison\" class=\"wp-block-heading\">Snabbj\u00e4mf\u00f6relse: B-kurva vs C-kurva vs D-kurva<\/h2>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table><thead><tr><th>Egenskaper<\/th><th>Gemensamt omr\u00e5de f\u00f6r omedelbar utl\u00f6sning<\/th><th>Allm\u00e4n bakgrund om startstr\u00f6m<\/th><\/tr><\/thead><tbody><tr><td>B-kurvan<\/td><td>3\u20135 \u00d7 In<\/td><td>L\u00e4gre f\u00f6rv\u00e4ntad startstr\u00f6m<\/td><\/tr><tr><td>C-kurvan<\/td><td>5\u201310 \u00d7 In<\/td><td>En m\u00e5ttlig startstr\u00f6m f\u00f6rv\u00e4ntas<\/td><\/tr><tr><td>D-kurvan<\/td><td>10\u201320 \u00d7 tum<\/td><td>H\u00f6gre f\u00f6rv\u00e4ntad startstr\u00f6m<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Dessa intervall beskriver de allm\u00e4nna egenskaper som dokumenterats av de st\u00f6rsta tillverkarna av MCB-brytare. De b\u00f6r inte betraktas som en modellspecifik RITOKS-tid-str\u00f6mkurva, s\u00e5vida inte detta uttryckligen bekr\u00e4ftas i den exakta produktdokumentationen fr\u00e5n RITOKS.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.eaton.com\/content\/dam\/eaton\/products\/electrical-circuit-protection\/industrial-miniature-circuit-breakers\/Industrial-breakers-catalog-ca08100005e.pdf\" target=\"_blank\" rel=\"noopener\">Eatons v\u00e4gledning om industriella miniatyrbrytare<\/a>, beskriver till exempel B-karakteristiken f\u00f6r situationer med l\u00e5g startstr\u00f6m, C f\u00f6r situationer med medelh\u00f6g startstr\u00f6m och D f\u00f6r situationer med h\u00f6g startstr\u00f6m. I till\u00e4mpningsanvisningarna ges exempel s\u00e5som sm\u00e5 transformatorer och styrutrustning f\u00f6r C-egenskaper, samt utrustning med h\u00f6gre startstr\u00f6m s\u00e5som motorer, transformatorer och str\u00f6mf\u00f6rs\u00f6rjningar f\u00f6r D-egenskaper. Dessa \u00e4r typiska exempel, inte universella regler f\u00f6r val av belastning.<\/p>\n\n\n\n<figure data-spectra-id=\"spectra-13d0c821-c4ad-469d-b691-b431655d6752\" class=\"wp-block-image aligncenter size-full has-custom-border\" ><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/b-c-d-curve-options-comparison.png\" alt=\"Begreppsm\u00e4ssig j\u00e4mf\u00f6relse av MCB-alternativ med B-, C- och D-kurvor\" class=\"wp-image-702\"  width=\"1672\" height=\"941\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/b-c-d-curve-options-comparison.png 1672w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/b-c-d-curve-options-comparison-600x338.png 600w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/b-c-d-curve-options-comparison-300x169.png 300w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/b-c-d-curve-options-comparison-1024x576.png 1024w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/b-c-d-curve-options-comparison-768x432.png 768w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/b-c-d-curve-options-comparison-1536x864.png 1536w\" sizes=\"auto, (max-width: 1672px) 100vw, 1672px\" \/><figcaption class=\"wp-element-caption\">J\u00e4mf\u00f6relse mellan de konceptuella kurvorna B, C och D. Kurvbeteckningen \u00e4r en urvalsparameter och den exakta modeldokumentationen m\u00e5ste verifieras.<\/figcaption><\/figure>\n\n\n\n<h2 id=\"mcb-trip-curve\" class=\"wp-block-heading\">Vad \u00e4r en MCB-utl\u00f6sningskurva?<\/h2>\n\n\n<p class=\"wp-block-paragraph\">En MCB skyddar en krets mot \u00f6verstr\u00f6m, men hur den reagerar beror inte bara p\u00e5 dess m\u00e4rkstr\u00f6m.<\/p>\n<p class=\"wp-block-paragraph\">En resekarakteristik beskriver en del av den reaktionen.<\/p>\n<p class=\"wp-block-paragraph\">N\u00e4r det g\u00e4ller MCB-brytare av typ B, C och D \u00e4r en av de mest uppenbara skillnaderna omr\u00e5det f\u00f6r omedelbar eller magnetisk utl\u00f6sning.<\/p>\n<p class=\"wp-block-paragraph\">T\u00e4nk dig tv\u00e5 brytare med samma nominella str\u00f6mstyrka.<\/p>\n<p class=\"wp-block-paragraph\">En B-kurvbrytare och en D-kurvbrytare kan b\u00e5da ha samma m\u00e4rkstr\u00f6m under normala f\u00f6rh\u00e5llanden, men deras omr\u00e5den f\u00f6r omedelbar utl\u00f6sning kan skilja sig v\u00e4sentligt \u00e5t.<\/p>\n<p class=\"wp-block-paragraph\">Det \u00e4r d\u00e4rf\u00f6r:<\/p>\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p class=\"wp-block-paragraph\">\u201c32 A B-kurva\u201d och \u201c32 A D-kurva\u201d beskriver inte samma skyddsbeteende bara f\u00f6r att b\u00e5da brytarna har en m\u00e4rkstr\u00f6m p\u00e5 32 A.<\/p><\/blockquote>\n\n\n<p class=\"wp-block-paragraph\">Kurvan \u00e4r d\u00e4rf\u00f6r ytterligare en urvalsparameter vid sidan av:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>m\u00e4rkstr\u00f6m<\/li>\n<li>sp\u00e4nning<\/li>\n<li>stolpar<\/li>\n<li>brytkapacitet<\/li>\n<li>monteringsformat<\/li>\n<li>exakt modell<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">F\u00f6r mer information om urvalsprocessen, se <a href=\"https:\/\/ritoks.com\/sv\/ac-mcb-selection-guide\/\">V\u00e4gledning f\u00f6r val av AC-MCB: Str\u00f6m, poler, utl\u00f6sningskurva och brytf\u00f6rm\u00e5ga<\/a>.<\/p>\n\n\n\n<h2 id=\"b-curve\" class=\"wp-block-heading\">Vad \u00e4r en B-kurva-MCB?<\/h2>\n\n\n<p class=\"wp-block-paragraph\">En A\/B-karakt\u00e4ristik har vanligtvis ett omr\u00e5de f\u00f6r omedelbar utl\u00f6sning p\u00e5 cirka 3\u20135 g\u00e5nger m\u00e4rkstr\u00f6mmen.<\/p>\n<p class=\"wp-block-paragraph\">Generellt sett inneb\u00e4r detta att det momentana magnetiska omr\u00e5det uppn\u00e5s vid en l\u00e4gre multipel av m\u00e4rkstr\u00f6mmen \u00e4n vid C- eller D-karakt\u00e4ristiker.<\/p>\n<p class=\"wp-block-paragraph\">Enligt tillverkarens riktlinjer placeras B-egenskaper vanligtvis d\u00e4r man kan f\u00f6rv\u00e4nta sig en relativt l\u00e5g startstr\u00f6m.<\/p>\n<p class=\"wp-block-paragraph\">Detta b\u00f6r dock inte omvandlas till en regel av typen:<\/p>\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p class=\"wp-block-paragraph\">\u201cAlla belysningskretsar m\u00e5ste anv\u00e4nda B-kurvan.\u201d<\/p><\/blockquote>\n<p class=\"wp-block-paragraph\">Det faktiska valet beror p\u00e5 kretsen, den f\u00f6rv\u00e4ntade startstr\u00f6mmen, felf\u00f6rh\u00e5llanden och g\u00e4llande konstruktionskrav.<\/p>\n\n\n<h3 class=\"wp-block-heading\">Aktuell tillg\u00e4nglighet f\u00f6r RITOKS B-kurvor<\/h3>\n\n\n<p class=\"wp-block-paragraph\">Aktuellt publicerat <a href=\"https:\/\/ritoks.com\/sv\/product-category\/ac-power-protection\/\">Data f\u00f6r RITOKS AC MCB<\/a> bekr\u00e4ftar att B-kurvan finns tillg\u00e4nglig p\u00e5:<\/p>\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/ritoks.com\/sv\/products\/miniature-circuit-breaker-63a-10ka\/\">RTSXD01<\/a> \u2014 B \/ C \/ D<\/li>\n<li>RTSXD03 \u2014 B \/ C<\/li>\n<li><a href=\"https:\/\/ritoks.com\/sv\/products\/1pn-miniature-circuit-breaker-32a-6ka\/\">RTSXD02<\/a> \u2014 B \/ C<\/li>\n<li><a href=\"https:\/\/ritoks.com\/sv\/products\/miniature-circuit-breaker-63a-10ka-pro\/\">RTSXD04<\/a> \u2014 B \/ C \/ D<\/li>\n<li><a href=\"https:\/\/ritoks.com\/sv\/products\/m60-ac-miniature-circuit-breaker-6-63a\/\">RTS-ACM60<\/a> \u2014 B \/ C<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">Ruttkurvan f\u00f6r RTS-AC47 \u00e4r f\u00f6r n\u00e4rvarande inte bekr\u00e4ftad.<\/p>\n<p class=\"wp-block-paragraph\">Dessa uppgifter bekr\u00e4ftar endast tillg\u00e4ngligheten. De anger inte det exakta modellspecifika tids-str\u00f6m-f\u00f6rh\u00e5llandet ut\u00f6ver den publicerade kurvbeteckningen.<\/p>\n\n\n<h2 id=\"c-curve\" class=\"wp-block-heading\">Vad \u00e4r en C-kurv-MCB?<\/h2>\n\n\n<p class=\"wp-block-paragraph\">En C-karakt\u00e4ristik har vanligtvis ett omr\u00e5de f\u00f6r omedelbar utl\u00f6sning p\u00e5 cirka 5\u201310 g\u00e5nger m\u00e4rkstr\u00f6mmen.<\/p>\n<p class=\"wp-block-paragraph\">J\u00e4mf\u00f6rt med B-karakt\u00e4ristiken m\u00f6jligg\u00f6r detta en h\u00f6gre str\u00f6mmultipel under korta tidsintervall innan man n\u00e5r omr\u00e5det f\u00f6r omedelbar utl\u00f6sning.<\/p>\n<p class=\"wp-block-paragraph\">Eaton beskriver C-karakt\u00e4ristiken som l\u00e4mplig f\u00f6r situationer med medelh\u00f6g startstr\u00f6m och ger exempel som sm\u00e5 transformatorer, belysning, kontrollampor, styrkretsar och spolar. Det \u00e4r anv\u00e4ndbar allm\u00e4n information, men det betyder inte att var och en av dessa till\u00e4mpningar automatiskt kr\u00e4ver en C-kurva.<\/p>\n\n\n<h3 class=\"wp-block-heading\">Aktuell tillg\u00e4nglighet f\u00f6r RITOKS C-Curve<\/h3>\n\n<p class=\"wp-block-paragraph\">C-kurvan \u00e4r f\u00f6r n\u00e4rvarande den kurva som har bekr\u00e4ftats i st\u00f6rst utstr\u00e4ckning bland de publicerade RITOKS AC MCB-familjerna:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>RTSXD01 \u2014 B \/ C \/ D<\/li>\n<li>RTSXD03 \u2014 B \/ C<\/li>\n<li>RTSXD02 \u2014 B \/ C<\/li>\n<li>RTSXD04 \u2014 B \/ C \/ D<\/li>\n<li>RTS-ACM60 \u2014 B \/ C<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">\u00c5terigen: RTS-AC47 har f\u00f6r n\u00e4rvarande ingen bekr\u00e4ftad kurvbeteckning p\u00e5 webbplatsen.<\/p>\n\n\n<h2 id=\"d-curve\" class=\"wp-block-heading\">Vad \u00e4r en D-kurvformad jordfelsbrytare (MCB)?<\/h2>\n\n\n<p class=\"wp-block-paragraph\">En D-karakt\u00e4ristik anv\u00e4nder vanligtvis ett omr\u00e5de f\u00f6r omedelbar utl\u00f6sning p\u00e5 cirka 10\u201320 g\u00e5nger m\u00e4rkstr\u00f6mmen.<\/p>\n<p class=\"wp-block-paragraph\">Detta \u00e4r den h\u00f6gsta av de tre vanliga momentana regionerna som diskuteras h\u00e4r.<\/p>\n<p class=\"wp-block-paragraph\">I tillverkarens riktlinjer kopplas D-egenskaper ofta till utrustning med h\u00f6g startstr\u00f6m. Eaton n\u00e4mner motorer, transformatorer, str\u00f6mf\u00f6rs\u00f6rjningsenheter och andra system med h\u00f6g induktans som typiska exempel.<\/p>\n<p class=\"wp-block-paragraph\">Ordet \u201dtypisk\u201d spelar roll.<\/p>\n<p class=\"wp-block-paragraph\">Det vore felaktigt att dra slutsatsen att:<\/p>\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p class=\"wp-block-paragraph\">\u201cMotor = D-kurva.\u201d<\/p><\/blockquote>\n<p class=\"wp-block-paragraph\">En motorkrets kan omfatta m\u00e5nga variabler, bland annat startegenskaper och den \u00f6vergripande skyddskonstruktionen. Brytarkurvan b\u00f6r d\u00e4rf\u00f6r v\u00e4ljas utifr\u00e5n verifierade tekniska krav snarare \u00e4n enbart utifr\u00e5n utrustningens ben\u00e4mning.<\/p>\n\n\n<h3 class=\"wp-block-heading\">Aktuell tillg\u00e4nglighet av RITOKS D-Curve<\/h3>\n\n<p class=\"wp-block-paragraph\">Aktuella publicerade RITOKS-data bekr\u00e4ftar D-kurvan f\u00f6r:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>RTSXD01<\/li>\n<li>RTSXD04<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">F\u00f6r de \u00f6vriga AC MCB-serierna som f\u00f6r n\u00e4rvarande finns publicerade finns det ingen bekr\u00e4ftad information om tillg\u00e4ngligheten av D-kurvor p\u00e5 deras produktsidor.<\/p>\n\n\n<h2 id=\"why-curves-differ\" class=\"wp-block-heading\">Varf\u00f6r kurvorna anv\u00e4nder olika momentana omr\u00e5den<\/h2>\n\n\n<p class=\"wp-block-paragraph\">Elektrisk utrustning kan under en kort stund dra str\u00f6m som \u00f6verstiger dess normala driftsniv\u00e5.<\/p>\n<p class=\"wp-block-paragraph\">Detta kan intr\u00e4ffa vid h\u00e4ndelser som till exempel sp\u00e4nningsp\u00e5slag eller uppstart.<\/p>\n<p class=\"wp-block-paragraph\">Om brytarens omr\u00e5de f\u00f6r omedelbar utl\u00f6sning \u00e4r f\u00f6r l\u00e5gt f\u00f6r den f\u00f6rv\u00e4ntade kortvariga str\u00f6mmen kan brytaren l\u00f6sa ut \u00e4ven om h\u00e4ndelsen ingick i den normala uppstarten av utrustningen.<\/p>\n<p class=\"wp-block-paragraph\">\u00c5 andra sidan \u00e4r det inte automatiskt b\u00e4ttre att bara v\u00e4lja en kurva med ett st\u00f6rre momentomr\u00e5de.<\/p>\n<p class=\"wp-block-paragraph\">Skyddssystemet m\u00e5ste fortfarande reagera p\u00e5 l\u00e4mpligt s\u00e4tt vid faktiska fel.<\/p>\n<p class=\"wp-block-paragraph\">D\u00e4rf\u00f6r b\u00f6r egenskaperna B, C och D betraktas som olika skyddsegenskaper, inte som kvalitetsklasser.<\/p>\n<p class=\"wp-block-paragraph\">D \u00e4r inte en \u201cpremiumversion\u201d av C, och C \u00e4r inte en \u201cuppgradering\u201d fr\u00e5n B.<\/p>\n\n\n<h2 id=\"same-rated-current\" class=\"wp-block-heading\">B j\u00e4mf\u00f6rt med C j\u00e4mf\u00f6rt med D vid samma m\u00e4rkstr\u00f6m<\/h2>\n\n\n<p class=\"wp-block-paragraph\">T\u00e4nk dig tre automatiska str\u00f6mbrytare som alla har samma m\u00e4rkstr\u00f6m, In.<\/p>\n<p class=\"wp-block-paragraph\">Med utg\u00e5ngspunkt fr\u00e5n de vanliga karakteristiska intervallen:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>B n\u00e5r sitt momentana omr\u00e5de vid ungef\u00e4r 3\u20135 \u00d7 In<\/li>\n<li>C cirka 5\u201310 \u00d7 In<\/li>\n<li>D cirka 10\u201320 \u00d7 In<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">Enbart som exempel: om In = 10 A, motsvarar dessa multiplar matematiskt:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>B: cirka 30\u201350 A<\/li>\n<li>C: cirka 50\u2013100 A<\/li>\n<li>D: cirka 100\u2013200 A<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">Detta r\u00e4kneexempel illustrerar endast inneb\u00f6rden av multiplarna. Det utg\u00f6r inte n\u00e5gon rekommendation f\u00f6r val av produkt och b\u00f6r inte betraktas som det exakta driftsbeteendet hos en specifik RITOKS-brytare.<\/p>\n<p class=\"wp-block-paragraph\">Brytaren faktiska beteende m\u00e5ste kontrolleras mot tillverkarens exakta dokumentation om tid-str\u00f6m-f\u00f6rh\u00e5llanden och g\u00e4llande produktkrav.<\/p>\n\n\n<h2 id=\"curve-availability\" class=\"wp-block-heading\">\u00d6versikt \u00f6ver aktuell tillg\u00e4nglighet f\u00f6r RITOKS-kurvor<\/h2>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table><thead><tr><th>RITOKS-modellen<\/th><th>B<\/th><th>C<\/th><th>D<\/th><th>Aktuell forskning<\/th><\/tr><\/thead><tbody><tr><td>RTSXD01<\/td><td>Ja<\/td><td>Ja<\/td><td>Ja<\/td><td>Publicerad tillg\u00e4nglighet<\/td><\/tr><tr><td>RTSXD03<\/td><td>Ja<\/td><td>Ja<\/td><td>\u2014<\/td><td>Publicerad tillg\u00e4nglighet<\/td><\/tr><tr><td>RTSXD02<\/td><td>Ja<\/td><td>Ja<\/td><td>\u2014<\/td><td>Publicerad tillg\u00e4nglighet<\/td><\/tr><tr><td>RTSXD04<\/td><td>Ja<\/td><td>Ja<\/td><td>Ja<\/td><td>Publicerad tillg\u00e4nglighet<\/td><\/tr><tr><td>RTS-ACM60<\/td><td>Ja<\/td><td>Ja<\/td><td>\u2014<\/td><td>Publicerad tillg\u00e4nglighet<\/td><\/tr><tr><td>RTS-AC47<\/td><td>Ej bekr\u00e4ftat<\/td><td>Ej bekr\u00e4ftat<\/td><td>Ej bekr\u00e4ftat<\/td><td>Kurvan \u00e4r inte bekr\u00e4ftad<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n<p class=\"wp-block-paragraph\">Denna tabell ska endast anv\u00e4ndas f\u00f6r att g\u00f6ra ett urval av produktfamiljer.<\/p>\n<p class=\"wp-block-paragraph\">Det betyder inte att de externa tillverkarkurvor som n\u00e4mndes tidigare \u00e4r de exakta, testade tid-str\u00f6m-kurvorna f\u00f6r dessa RITOKS-modeller.<\/p>\n\n\n<figure data-spectra-id=\"spectra-a53875d0-a1bc-48eb-8fdd-2bdc47a255ab\" class=\"wp-block-image aligncenter size-full has-custom-border\" ><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-pole-formats-panel.png\" alt=\"Olika polkonfigurationer f\u00f6r miniatyrstr\u00f6mavbrytare f\u00f6r v\u00e4xelstr\u00f6m i en industriell f\u00f6rdelningspanel\" class=\"wp-image-703\"  width=\"1672\" height=\"941\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-pole-formats-panel.png 1672w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-pole-formats-panel-600x338.png 600w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-pole-formats-panel-300x169.png 300w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-pole-formats-panel-1024x576.png 1024w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-pole-formats-panel-768x432.png 768w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-pole-formats-panel-1536x864.png 1536w\" sizes=\"auto, (max-width: 1672px) 100vw, 1672px\" \/><figcaption class=\"wp-element-caption\">Exempel p\u00e5 produktutf\u00f6randen f\u00f6r v\u00e4xelstr\u00f6ms-MCB:ar; kurvdata och elektriska v\u00e4rden m\u00e5ste bekr\u00e4ftas f\u00f6r den exakta modellen.<\/figcaption><\/figure>\n\n\n\n<h2 id=\"selection-process\" class=\"wp-block-heading\">Hur man v\u00e4ljer mellan alternativ med B-, C- och D-kurvor<\/h2>\n\n\n<p class=\"wp-block-paragraph\">Den praktiska ink\u00f6psprocessen utg\u00e5r fr\u00e5n den egenskap som kr\u00e4vs, inte fr\u00e5n en gissning baserad p\u00e5 produktnamnet.<\/p>\n\n<h3 class=\"wp-block-heading\">1. Kontrollera kraven p\u00e5 belastning och startstr\u00f6m<\/h3>\n<p class=\"wp-block-paragraph\">Ta reda p\u00e5 om projektdokumentationen redan inneh\u00e5ller f\u00f6ljande:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>f\u00f6rv\u00e4ntad startstr\u00f6m<\/li>\n<li>startstr\u00f6m<\/li>\n<li>n\u00f6dv\u00e4ndig kurva<\/li>\n<li>andra skyddsbegr\u00e4nsningar<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">Om den \u00f6nskade kurvan redan har angetts, anv\u00e4nd den som utg\u00e5ngspunkt.<\/p>\n\n<h3 class=\"wp-block-heading\">2. Kontrollera m\u00e4rkstr\u00f6mmen<\/h3>\n<p class=\"wp-block-paragraph\">Utl\u00f6sningskurvan och m\u00e4rkstr\u00f6mmen \u00e4r separata parametrar.<\/p>\n<p class=\"wp-block-paragraph\">Till exempel:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>C16<\/li>\n<li>C32<\/li>\n<li>C63<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">Alla har beteckningen C men olika str\u00f6mv\u00e4rden.<\/p>\n<p class=\"wp-block-paragraph\">V\u00e4lj inte kurvan f\u00f6rst och bortse inte fr\u00e5n den erforderliga brytarstr\u00f6mmen.<\/p>\n\n<h3 class=\"wp-block-heading\">3. Kontrollera brytkapaciteten<\/h3>\n<p class=\"wp-block-paragraph\">K\u00f6rkurva och <a href=\"https:\/\/ritoks.com\/sv\/6ka-vs-10ka-mcb-breaking-capacity\/\">6 kA j\u00e4mf\u00f6rt med 10 kA \u2013 MCB:s brytf\u00f6rm\u00e5ga<\/a> \u00e4r ocks\u00e5 olika parametrar.<\/p>\n<p class=\"wp-block-paragraph\">En beteckning av typen A, B, C eller D ger ingen information om huruvida brytaren har:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>6 kA<\/li>\n<li>10 kA<\/li>\n<li>eller ett annat v\u00e4rde f\u00f6r brytkapacitet<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">Denna egenskap m\u00e5ste kontrolleras separat p\u00e5 just den aktuella produkten.<\/p>\n\n<h3 class=\"wp-block-heading\">4. Bekr\u00e4fta polkonfigurationen<\/h3>\n<p class=\"wp-block-paragraph\">En obligatorisk B\/C\/D-kurva kan endast vara till nytta om samma produktfamilj \u00e4ven erbjuder f\u00f6ljande krav:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>1P<\/li>\n<li>1P+N<\/li>\n<li>2P<\/li>\n<li>3P<\/li>\n<li>3P+N<\/li>\n<li>4P<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">konfiguration.<\/p>\n\n<h3 class=\"wp-block-heading\">5. Kontrollera att produktdokumentationen st\u00e4mmer<\/h3>\n<p class=\"wp-block-paragraph\">Det sista steget \u00e4r att kontrollera sj\u00e4lva den valda brytaren.<\/p>\n<p class=\"wp-block-paragraph\">G\u00e5 inte ut fr\u00e5n f\u00f6ljande:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>varje B-kurva uppvisar samma beteende hos alla tillverkare<\/li>\n<li>Varje C-kurva har identiska toleranser f\u00f6r tid och str\u00f6m<\/li>\n<li>Varje D-kurva \u00e4r l\u00e4mplig f\u00f6r alla laster med h\u00f6g startstr\u00f6m.<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">Kurvbeteckningen \u00e4r en del av den fullst\u00e4ndiga produktspecifikationen.<\/p>\n\n\n<h2 id=\"common-mistakes\" class=\"wp-block-heading\">Vanliga misstag vid val av B\/C\/D-kurvor<\/h2>\n\n\n<h3 class=\"wp-block-heading\">Att betrakta B, C och D som kvalitetsniv\u00e5er<\/h3>\n<p class=\"wp-block-paragraph\">Det handlar om olika resetyper, inte om \u201cgrundl\u00e4ggande\u201d, \u201cb\u00e4ttre\u201d och \u201cb\u00e4st\u201d.\u201d<\/p>\n\n<h3 class=\"wp-block-heading\">V\u00e4lja enbart utifr\u00e5n lastnamnet<\/h3>\n<p class=\"wp-block-paragraph\">Uttalanden som \u201cmotor inneb\u00e4r D-kurva\u201d \u00e4r alltf\u00f6r allm\u00e4nna.<\/p>\n<p class=\"wp-block-paragraph\">Man m\u00e5ste ta h\u00e4nsyn till den f\u00f6rv\u00e4ntade startstr\u00f6mmen och den faktiska elektriska konstruktionen.<\/p>\n\n<h3 class=\"wp-block-heading\">Att bortse fr\u00e5n m\u00e4rkstr\u00f6mmen<\/h3>\n<p class=\"wp-block-paragraph\">En korrekt kurva i kombination med fel str\u00f6mv\u00e4rde inneb\u00e4r att brytaren inte \u00e4r r\u00e4tt vald.<\/p>\n\n<h3 class=\"wp-block-heading\">Att bortse fr\u00e5n brytkapaciteten<\/h3>\n<p class=\"wp-block-paragraph\">B\/C\/D-karakteristiken och bromsf\u00f6rm\u00e5gan \u00e4r separata parametrar.<\/p>\n\n<h3 class=\"wp-block-heading\">Antagande att externa kurvdata automatiskt till\u00e4mpas p\u00e5 alla RITOKS-modeller<\/h3>\n<p class=\"wp-block-paragraph\">V\u00e4rdena 3\u20135 \u00d7 In, 5\u201310 \u00d7 In och 10\u201320 \u00d7 In som anv\u00e4nds i denna handbok \u00e4r allm\u00e4nna karakteristiska intervall som st\u00f6ds av tillf\u00f6rlitlig teknisk dokumentation fr\u00e5n tillverkarna. P\u00e5 RITOKS produktsidor anges f\u00f6r n\u00e4rvarande vilka kurvbeteckningar som finns tillg\u00e4ngliga, men d\u00e4r publiceras inte fullst\u00e4ndiga modellspecifika tid-str\u00f6mkurvor.<\/p>\n\n<h3 class=\"wp-block-heading\">Skapa ett kurvdiagram utan modelldata<\/h3>\n<p class=\"wp-block-paragraph\">En graf som ser realistisk ut kan ge intryck av st\u00f6rre precision \u00e4n vad de tillg\u00e4ngliga bevisen ger st\u00f6d f\u00f6r.<\/p>\n<p class=\"wp-block-paragraph\">Tills dess att exakt tids- och str\u00f6mdokumentation f\u00f6r RITOKS-modeller finns tillg\u00e4nglig b\u00f6r valet av kurva baseras p\u00e5 den publicerade beteckningen och projektkraven, snarare \u00e4n p\u00e5 en p\u00e5hittad graf.<\/p>\n\n\n<h2 id=\"request-technical-data\" class=\"wp-block-heading\">N\u00e4r b\u00f6r man beg\u00e4ra ytterligare tekniska uppgifter?<\/h2>\n\n\n<p class=\"wp-block-paragraph\">Vid en vanlig ink\u00f6psf\u00f6rfr\u00e5gan kan det r\u00e4cka med att k\u00e4nna till den \u00f6nskade kurvbeteckningen f\u00f6r att g\u00f6ra ett urval bland tillg\u00e4ngliga modeller.<\/p>\n<p class=\"wp-block-paragraph\">F\u00f6r en mer ing\u00e5ende teknisk granskning kan k\u00f6pare beh\u00f6va ytterligare dokumentation, till exempel:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>exakt tid-str\u00f6m-kurva<\/li>\n<li>tolerans f\u00f6r omedelbar utl\u00f6sning<\/li>\n<li>data om brytkapacitet<\/li>\n<li>g\u00e4llande produktstandard<\/li>\n<li>samordningsinformation vid behov<\/li>\n<li>modellspecifika test- eller certifieringsdokument<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">Dessa krav b\u00f6r beg\u00e4ras f\u00f6r just den aktuella produkten, ist\u00e4llet f\u00f6r att man utg\u00e5r fr\u00e5n bokst\u00e4verna B, C eller D enbart.<\/p>\n\n\n<h2 id=\"frequently-asked-questions\" class=\"wp-block-heading\">Vanliga fr\u00e5gor<\/h2>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Vad \u00e4r den st\u00f6rsta skillnaden mellan MCB:er med kurvorna B, C och D?<\/summary>\n<p class=\"wp-block-paragraph\">Den viktigaste skillnaden som tas upp h\u00e4r \u00e4r omr\u00e5det f\u00f6r omedelbar utl\u00f6sning. I vanlig tillverkardokumentation anges v\u00e4rden p\u00e5 cirka 3\u20135 \u00d7 In f\u00f6r B, 5\u201310 \u00d7 In f\u00f6r C och 10\u201320 \u00d7 In f\u00f6r D.<\/p>\n<\/details>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>\u00c4r C-kurvan b\u00e4ttre \u00e4n B-kurvan?<\/summary>\n<p class=\"wp-block-paragraph\">Nej. De har olika utl\u00f6sningsegenskaper. Vilket val som \u00e4r l\u00e4mpligt beror p\u00e5 kretsen och de f\u00f6rv\u00e4ntade startstr\u00f6msf\u00f6rh\u00e5llandena.<\/p>\n<\/details>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Anv\u00e4nds D-kurvan alltid f\u00f6r motorer?<\/summary>\n<p class=\"wp-block-paragraph\">Nej. D-kurvan f\u00f6rknippas vanligtvis med till\u00e4mpningar med h\u00f6gt startstr\u00f6m, och i tillverkarens riktlinjer anges ofta motorer och transformatorer som exempel, men vilken kurva som \u00e4r korrekt beror p\u00e5 den faktiska utrustningen och skyddskonstruktionen.<\/p>\n<\/details>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Erbjuder RITOKS MCB-brytare med kurvorna B, C och D?<\/summary>\n<p class=\"wp-block-paragraph\">Ja, f\u00f6r vissa produktserier. RTSXD01 och RTSXD04 har f\u00f6r n\u00e4rvarande alternativen B\/C\/D. RTSXD02, RTSXD03 och RTS-ACM60 har alternativen B\/C. RTS-AC47 har f\u00f6r n\u00e4rvarande ingen bekr\u00e4ftad kurvbeteckning.<\/p>\n<\/details>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Kan man avl\u00e4sa brytkapaciteten p\u00e5 en kurvkurva?<\/summary>\n<p class=\"wp-block-paragraph\">Nej. Slagl\u00e4ngd och bromsf\u00f6rm\u00e5ga \u00e4r separata produktparametrar och b\u00f6r b\u00e5da kontrolleras.<\/p>\n<\/details>\n\n\n\n<div class=\"wp-block-group has-ast-global-color-5-color has-ast-global-color-2-background-color has-text-color has-background is-layout-constrained wp-container-core-group-is-layout-737f6912 wp-block-group-is-layout-constrained\" style=\"border-radius:6px;margin-top:48px;padding-top:40px;padding-right:32px;padding-bottom:40px;padding-left:32px\">\n\n\n<h2 class=\"wp-block-heading\">Beh\u00f6ver du hj\u00e4lp med att v\u00e4lja en utl\u00f6sningskurva f\u00f6r en MCB?<\/h2>\n\n\n<p class=\"wp-block-paragraph\">RITOKS erbjuder serier av miniatyrstr\u00f6mavbrytare f\u00f6r v\u00e4xelstr\u00f6m med olika m\u00e4rkstr\u00f6m, polkonfigurationer, brytkapacitet och tillg\u00e4nglighet av B-, C- och D-kurvor.<\/p>\n<p class=\"wp-block-paragraph\">Anv\u00e4nd en <a href=\"https:\/\/ritoks.com\/sv\/ac-mcb-rfq-checklist\/\">Checklista f\u00f6r offertf\u00f6rfr\u00e5gan avseende v\u00e4xelstr\u00f6ms- och jordfelsbrytare (AC MCB)<\/a> att tillhandah\u00e5lla:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>V\u00e4xelsp\u00e4nning<\/li>\n<li>n\u00f6dv\u00e4ndig str\u00f6m<\/li>\n<li>polkonfiguration<\/li>\n<li>n\u00f6dv\u00e4ndig r\u00f6relsekurva<\/li>\n<li>kr\u00e4vd brytkapacitet<\/li>\n<li>antal<\/li>\n<li>ans\u00f6kan<\/li>\n<li>all n\u00f6dv\u00e4ndig teknisk dokumentation<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">RITOKS kan sedan j\u00e4mf\u00f6ra f\u00f6rfr\u00e5gan med de produktfamiljer som f\u00f6r n\u00e4rvarande \u00e4r publicerade och med bekr\u00e4ftade modelluppgifter.<\/p>\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-ast-global-color-0-background-color has-background wp-element-button\" href=\"https:\/\/ritoks.com\/sv\/product-category\/ac-power-protection\/miniature-circuit-breakers\/\">Visa AC-miniatyrbrytare \u2192<\/a><\/div>\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-ast-global-color-0-background-color has-background wp-element-button\" href=\"https:\/\/ritoks.com\/sv\/ac-mcb-selection-guide\/\">L\u00e4s v\u00e4gledningen f\u00f6r val av AC-MCB \u2192<\/a><\/div>\n<div class=\"wp-block-button is-style-outline is-style-outline--1\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/ritoks.com\/sv\/contact-us\/\">Kontakta RITOKS \u2192 Beg\u00e4r en offert<\/a><\/div>\n<\/div>\n\n\n<\/div>\n\n\n<\/div>","protected":false},"excerpt":{"rendered":"<p>B Curve vs C Curve vs D Curve MCBs: What\u2019s the Difference? B, C and D curves are different tripping [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"no-sidebar","site-content-layout":"page-builder","ast-site-content-layout":"full-width-container","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"disabled","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"disabled","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ritoks_resource_detail_renderer":null,"ritoks_resource_product_cat_term_id":0,"footnotes":""},"categories":[64],"tags":[],"class_list":["post-699","post","type-post","status-publish","format-standard","hentry","category-circuit-protection"],"acf":[],"spectra_blocks_featured_image_url":null,"spectra_blocks_author_info":{"display_name":"RITOKS","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/6d7d0fc73468198f994ab13ef6eb6558c53b6ed1ad86364d5165efe8bdf8eb4a?s=96&d=mm&r=g","author_link":"https:\/\/ritoks.com\/sv\/author\/dazzlingwqbgmail-com\/","description":""},"_links":{"self":[{"href":"https:\/\/ritoks.com\/sv\/wp-json\/wp\/v2\/posts\/699","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ritoks.com\/sv\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ritoks.com\/sv\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ritoks.com\/sv\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/ritoks.com\/sv\/wp-json\/wp\/v2\/comments?post=699"}],"version-history":[{"count":4,"href":"https:\/\/ritoks.com\/sv\/wp-json\/wp\/v2\/posts\/699\/revisions"}],"predecessor-version":[{"id":731,"href":"https:\/\/ritoks.com\/sv\/wp-json\/wp\/v2\/posts\/699\/revisions\/731"}],"wp:attachment":[{"href":"https:\/\/ritoks.com\/sv\/wp-json\/wp\/v2\/media?parent=699"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ritoks.com\/sv\/wp-json\/wp\/v2\/categories?post=699"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ritoks.com\/sv\/wp-json\/wp\/v2\/tags?post=699"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}