{"id":762,"date":"2026-09-07T01:52:16","date_gmt":"2026-09-07T01:52:16","guid":{"rendered":"https:\/\/ritoks.com\/?p=762"},"modified":"2026-10-04T06:58:24","modified_gmt":"2026-10-04T06:58:24","slug":"mds-30a-250a-vs-300a-1200a-bridge-rectifier-modules","status":"publish","type":"post","link":"https:\/\/ritoks.com\/sv\/mds-30a-250a-vs-300a-1200a-bridge-rectifier-modules\/","title":{"rendered":"MDS 30A\u2013250A j\u00e4mf\u00f6rt med 300A\u20131200A brygglikriktarmoduler: Modellj\u00e4mf\u00f6relse"},"content":{"rendered":"<div class=\"wp-block-group alignfull has-ast-global-color-5-background-color has-background is-layout-constrained wp-container-core-group-is-layout-350090bf wp-block-group-is-layout-constrained\" style=\"padding-top:64px;padding-right:24px;padding-bottom:56px;padding-left:24px\">\n\n<p class=\"has-medium-font-size wp-block-paragraph\">RITOKS tillverkar f\u00f6r n\u00e4rvarande tv\u00e5 serier av MDS-moduler med trefas-brygglikriktare som t\u00e4cker olika str\u00f6mklassintervall:<\/p>\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-b4fe89e5 wp-block-columns-is-layout-flex\" style=\"margin-top:32px\">\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n\n<h3 class=\"wp-block-heading\"><a href=\"https:\/\/ritoks.com\/sv\/products\/mds-three-phase-bridge-rectifier-30a-250a\/\">MDS 30 A\u2013250 A<\/a><\/h3>\n\n\n<figure data-spectra-id=\"spectra-d7389813-de2f-4ae3-a50a-61a50623502e\" class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" height=\"617\" width=\"611\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/08\/ScreenShot_2026-08-30_150719_740.png\" alt=\"MDS-serien med trefasiga brygglikriktarmoduler fr\u00e5n 30 A till 250 A\" class=\"wp-image-340\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/08\/ScreenShot_2026-08-30_150719_740.png 611w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/08\/ScreenShot_2026-08-30_150719_740-100x100.png 100w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/08\/ScreenShot_2026-08-30_150719_740-600x606.png 600w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/08\/ScreenShot_2026-08-30_150719_740-150x150.png 150w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/08\/ScreenShot_2026-08-30_150719_740-297x300.png 297w\" sizes=\"auto, (max-width: 611px) 100vw, 611px\" \/><\/figure>\n\n<\/div>\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n\n<h3 class=\"wp-block-heading\"><a href=\"https:\/\/ritoks.com\/sv\/products\/mds-high-current-bridge-rectifier-300a-1200a\/\">MDS 300A\u20131200A<\/a><\/h3>\n\n\n<figure data-spectra-id=\"spectra-99c89a9d-fe6d-4887-a081-6952f0ac29e2\" class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" height=\"368\" width=\"523\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/08\/ScreenShot_2026-08-30_150805_720.png\" alt=\"MDS-serien med trefasiga brygglikriktarmoduler f\u00f6r h\u00f6ga str\u00f6mstyrkor fr\u00e5n 300 A till 1 200 A\" class=\"wp-image-342\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/08\/ScreenShot_2026-08-30_150805_720.png 523w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/08\/ScreenShot_2026-08-30_150805_720-300x211.png 300w\" sizes=\"auto, (max-width: 523px) 100vw, 523px\" \/><\/figure>\n\n<\/div>\n\n<\/div>\n\n<\/div>\n\n\n<div class=\"wp-block-group alignfull is-layout-constrained wp-container-core-group-is-layout-384c61b8 wp-block-group-is-layout-constrained\" style=\"padding-top:48px;padding-right:24px;padding-bottom:48px;padding-left:24px\">\n\n<p class=\"wp-block-paragraph\">B\u00e5da \u00e4r serier av MDS-trefas-brygglikriktare, men deras publicerade modellklasser \u00e4r indelade i tv\u00e5 serier.<\/p>\n\n\n<p class=\"wp-block-paragraph\">I den l\u00e4gre serien ing\u00e5r modeller fr\u00e5n 30 A till 250 A.<\/p>\n\n\n<p class=\"wp-block-paragraph\">I den h\u00f6gre serien ing\u00e5r modeller fr\u00e5n 300 A till 1 200 A.<\/p>\n\n\n<p class=\"wp-block-paragraph\">Denna j\u00e4mf\u00f6relse fokuserar endast p\u00e5 de skillnader som f\u00f6r n\u00e4rvarande har offentliggjorts.<\/p>\n\n\n<p class=\"wp-block-paragraph\">Det inneb\u00e4r inte att en viss familj betraktas som b\u00e4ttre, effektivare eller s\u00e4krare, och det inneb\u00e4r inte heller att den nuvarande klassindelningen omvandlas till en universell regel f\u00f6r modulstorlek.<\/p>\n\n\n<p class=\"wp-block-paragraph\">F\u00f6r mer omfattande urvalsprinciper, se <a href=\"https:\/\/ritoks.com\/sv\/mds-bridge-rectifier-module-selection-guide\/\">V\u00e4gledning f\u00f6r val av MDS-brygglikriktarmodul<\/a>.<\/p>\n\n<\/div>\n\n\n<div class=\"wp-block-group alignfull has-ast-global-color-4-background-color has-background is-layout-constrained wp-container-core-group-is-layout-b3c3a14d wp-block-group-is-layout-constrained\" style=\"padding-top:56px;padding-right:24px;padding-bottom:56px;padding-left:24px\">\n\n<h2 id=\"mds-bridge-rectifier-module-comparison\" class=\"wp-block-heading\">J\u00e4mf\u00f6relse av MDS-brygglikriktarmoduler<\/h2>\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table><thead><tr><th>Artikel<\/th><th>MDS 30 A\u2013250 A<\/th><th>MDS 300A\u20131200A<\/th><\/tr><\/thead><tbody><tr><td>Produktfamilj<\/td><td>MDS trefasig brygglikriktarmodul<\/td><td>MDS trefasig brolikriktarmodul f\u00f6r h\u00f6ga str\u00f6mstyrkor<\/td><\/tr><tr><td>Publicerat aktuellt sortiment<\/td><td>30A\u2013250A<\/td><td>300A\u20131200A<\/td><\/tr><tr><td>Publicerade modellklasser<\/td><td>30 \/ 60 \/ 75 \/ 100 \/ 150 \/ 200 \/ 250A<\/td><td>300 \/ 400 \/ 500 \/ 600 \/ 800 \/ 1000 \/ 1200A<\/td><\/tr><tr><td>Version med exakt sp\u00e4nning<\/td><td>Bekr\u00e4fta exakt modell<\/td><td>Bekr\u00e4fta exakt modell<\/td><\/tr><tr><td>Referensv\u00e4rde f\u00f6r leverant\u00f6rens belastningsstr\u00f6m<\/td><td>Publicerat av model<\/td><td>Publicerat av model<\/td><\/tr><tr><td>Referens f\u00f6r leverant\u00f6rens kylfl\u00e4ns<\/td><td>Publicerad av Model Group<\/td><td>Publicerad av Model Group<\/td><\/tr><tr><td>Kylningskonfiguration<\/td><td>Bekr\u00e4fta f\u00f6r applikation\/modell<\/td><td>Bekr\u00e4fta f\u00f6r applikation\/modell<\/td><\/tr><tr><td>Modulens m\u00e5tt<\/td><td>Har \u00e4nnu inte publicerats<\/td><td>Har \u00e4nnu inte publicerats; motstridiga h\u00e4nvisningar i sammanfattningen m\u00e5ste verifieras<\/td><\/tr><tr><td>Terminalens utformning<\/td><td>Bekr\u00e4fta exakt modell<\/td><td>Bekr\u00e4fta exakt modell<\/td><\/tr><tr><td>Monteringsanvisningar<\/td><td>Bekr\u00e4fta exakt modell<\/td><td>Bekr\u00e4fta exakt modell<\/td><\/tr><tr><td>Isoleringsdata<\/td><td>Ej publicerad<\/td><td>Ej publicerad<\/td><\/tr><tr><td>Certifiering \/ standarder<\/td><td>Ej publicerad<\/td><td>Ej publicerad<\/td><\/tr><tr><td>Datablad att ladda ner<\/td><td>F\u00f6r n\u00e4rvarande inte tillg\u00e4ngligt<\/td><td>F\u00f6r n\u00e4rvarande inte tillg\u00e4ngligt<\/td><\/tr><tr><td>Slutlig urval<\/td><td>Verifiering av exakt modell kr\u00e4vs<\/td><td>Verifiering av exakt modell kr\u00e4vs<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n<p class=\"wp-block-paragraph\">Den st\u00f6rsta skillnaden mellan de tv\u00e5 familjerna \u00e4r d\u00e4rf\u00f6r deras publicerade t\u00e4ckning av den aktuella klassen.<\/p>\n\n\n<p class=\"wp-block-paragraph\">Andra viktiga omr\u00e5den kr\u00e4ver fortfarande bekr\u00e4ftelse genom exakta modeller.<\/p>\n\n<\/div>\n\n\n<div class=\"wp-block-group alignfull has-border-color has-ast-global-color-5-background-color has-background is-layout-constrained wp-container-core-group-is-layout-52a4fad7 wp-block-group-is-layout-constrained\" style=\"border-color:#d8e3ef;border-width:1px;border-radius:6px;margin-top:32px;margin-bottom:32px;padding-top:32px;padding-right:24px;padding-bottom:32px;padding-left:24px\">\n\n<h3 class=\"wp-block-heading\">Publicerad j\u00e4mf\u00f6relse av aktuella kurser<\/h3>\n\n\n<figure data-spectra-id=\"spectra-41d59760-0cbc-48ba-9a1d-f72f67434f6c\" class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/mds-published-current-classes-comparison.jpg\" alt=\"Publicerad aktuell j\u00e4mf\u00f6relse mellan produktfamiljerna MDS 30A\u2013250A och MDS 300A\u20131200A med brygglikriktarmoduler\" class=\"wp-image-763\" width=\"1774\" height=\"887\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/mds-published-current-classes-comparison.jpg 1774w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/mds-published-current-classes-comparison-600x300.jpg 600w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/mds-published-current-classes-comparison-300x150.jpg 300w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/mds-published-current-classes-comparison-1024x512.jpg 1024w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/mds-published-current-classes-comparison-768x384.jpg 768w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/mds-published-current-classes-comparison-1536x768.jpg 1536w\" sizes=\"auto, (max-width: 1774px) 100vw, 1774px\" \/><figcaption class=\"wp-element-caption\">J\u00e4mf\u00f6relsen avser endast publicerade str\u00f6mklasser. Exakt sp\u00e4nningsversion, belastningsf\u00f6rh\u00e5llanden, kylningsl\u00f6sning och slutgiltig modelldokumentation m\u00e5ste bekr\u00e4ftas innan best\u00e4llning.<\/figcaption><\/figure>\n\n<\/div>\n\n\n<div class=\"wp-block-group alignfull is-layout-constrained wp-container-core-group-is-layout-384c61b8 wp-block-group-is-layout-constrained\" style=\"padding-top:48px;padding-right:24px;padding-bottom:48px;padding-left:24px\">\n\n<h2 id=\"mds-30a-250a-published-model-classes\" class=\"wp-block-heading\">1. MDS 30A\u2013250A \u2013 Publicerade modellklasser<\/h2>\n\n\n<p class=\"wp-block-paragraph\">MDS 30A\u2013250A-serien omfattar f\u00f6r n\u00e4rvarande sju str\u00f6mklasser:<\/p>\n\n\n<ul class=\"wp-block-list\">\n<li>MDS30A<\/li>\n\n<li>MDS60A<\/li>\n\n<li>MDS75A<\/li>\n\n<li>MDS100A<\/li>\n\n<li>MDS150A<\/li>\n\n<li>MDS200A<\/li>\n\n<li>MDS250A<\/li>\n<\/ul>\n\n\n<p class=\"wp-block-paragraph\">Denna familj t\u00e4cker den nedre delen av det f\u00f6r n\u00e4rvarande publicerade RITOKS MDS-intervallet.<\/p>\n\n\n<p class=\"wp-block-paragraph\">Vid upphandling kan en ink\u00f6pare anv\u00e4nda dessa publicerade klasser f\u00f6r att avg\u00f6ra om denna produktfamilj \u00e4r v\u00e4rd att utv\u00e4rdera mot bakgrund av ett befintligt projektkrav.<\/p>\n\n\n<p class=\"wp-block-paragraph\">Det betyder inte att det n\u00e4rmaste aktuella talet automatiskt blir r\u00e4tt modul.<\/p>\n\n\n<p class=\"wp-block-paragraph\">Den exakta sp\u00e4nningsversionen, driftsf\u00f6rh\u00e5llandena, kylningsl\u00f6sningen och modelldokumentationen m\u00e5ste fortfarande verifieras.<\/p>\n\n<\/div>\n\n\n<div class=\"wp-block-group alignfull is-layout-constrained wp-container-core-group-is-layout-384c61b8 wp-block-group-is-layout-constrained\" style=\"padding-top:48px;padding-right:24px;padding-bottom:48px;padding-left:24px\">\n\n<h2 id=\"mds-300a-1200a-published-model-classes\" class=\"wp-block-heading\">2. MDS 300A\u20131200A \u2013 publicerade modellklasser<\/h2>\n\n\n<p class=\"wp-block-paragraph\">MDS-serien f\u00f6r h\u00f6gre str\u00f6mniv\u00e5er omfattar dessutom sju str\u00f6mklasser:<\/p>\n\n\n<ul class=\"wp-block-list\">\n<li>MDS300A<\/li>\n\n<li>MDS400A<\/li>\n\n<li>MDS500A<\/li>\n\n<li>MDS600A<\/li>\n\n<li>MDS800A<\/li>\n\n<li>MDS1000A<\/li>\n\n<li>MDS1200A<\/li>\n<\/ul>\n\n\n<p class=\"wp-block-paragraph\">Detta ger ett angivet intervall fr\u00e5n 300 A till 1 200 A.<\/p>\n\n\n<p class=\"wp-block-paragraph\">Precis som f\u00f6r 30A\u2013250A-serien anger dessa siffror modellklasser.<\/p>\n\n\n<p class=\"wp-block-paragraph\">De fastst\u00e4ller inte n\u00e5gon regel av typen:<\/p>\n\n\n<p class=\"wp-block-paragraph\">belastningsstr\u00f6m = erforderlig MDS-str\u00f6mklass<\/p>\n\n\n<p class=\"wp-block-paragraph\">eller:<\/p>\n\n\n<p class=\"wp-block-paragraph\">V\u00e4lj n\u00e4sta aktuella klass ovanf\u00f6r lasten.<\/p>\n\n\n<p class=\"wp-block-paragraph\">Om produkten \u00e4r l\u00e4mplig beror p\u00e5 den fullst\u00e4ndiga ans\u00f6kan och exakta uppgifter om modellen.<\/p>\n\n<\/div>\n\n\n<div class=\"wp-block-group alignfull is-layout-constrained wp-container-core-group-is-layout-384c61b8 wp-block-group-is-layout-constrained\" style=\"padding-top:48px;padding-right:24px;padding-bottom:48px;padding-left:24px\">\n\n<h2 id=\"the-published-boundary-is-250a-to-300a\" class=\"wp-block-heading\">3. Den offentliggjorda gr\u00e4nsen \u00e4r 250A till 300A<\/h2>\n\n\n<p class=\"wp-block-paragraph\">De nuvarande produktsidorna f\u00f6r RITOKS skapar en tydlig gr\u00e4ns mellan de olika produktserierna:<\/p>\n\n\n<p class=\"wp-block-paragraph\">MDS 30A\u2013250A-serien: h\u00f6gsta angivna klass = 250 A<\/p>\n\n\n<p class=\"wp-block-paragraph\">MDS 300A\u20131200A-serien: l\u00e4gsta angivna klass = 300 A<\/p>\n\n\n<p class=\"wp-block-paragraph\">Det finns inga modeller i klasserna 251A\u2013299A listade p\u00e5 dessa tv\u00e5 aktuella produktsidor.<\/p>\n\n\n<p class=\"wp-block-paragraph\">Detta p\u00e5st\u00e5ende g\u00e4ller endast den RITOKS-familjestruktur som f\u00f6r n\u00e4rvarande har publicerats.<\/p>\n\n\n<p class=\"wp-block-paragraph\">Det betyder inte:<\/p>\n\n\n<ul class=\"wp-block-list\">\n<li>det finns inga andra betyg p\u00e5 den bredare marknaden<\/li>\n\n<li>F\u00f6r alla belastningar under 300 A b\u00f6r 250 A anv\u00e4ndas<\/li>\n\n<li>alla krav \u00f6ver 250 A b\u00f6r automatiskt baseras p\u00e5 300 A<\/li>\n\n<li>300A \u00e4r en universell \u00f6verg\u00e5ngspunkt f\u00f6r konstruktion av brygglikriktare<\/li>\n<\/ul>\n\n\n<p class=\"wp-block-paragraph\">Gr\u00e4nsen hj\u00e4lper helt enkelt k\u00f6parna att f\u00f6rst\u00e5 hur de tv\u00e5 RITOKS-produktfamiljerna \u00e4r uppbyggda.<\/p>\n\n<\/div>\n\n\n<div class=\"wp-block-group alignfull is-layout-constrained wp-container-core-group-is-layout-384c61b8 wp-block-group-is-layout-constrained\" style=\"padding-top:48px;padding-right:24px;padding-bottom:48px;padding-left:24px\">\n\n<h2 id=\"supplier-load-current-reference-data-30a-250a-family\" class=\"wp-block-heading\">4. Referensdata f\u00f6r leverant\u00f6rens belastningsstr\u00f6m: 30 A\u2013250 A-serien<\/h2>\n\n\n<p class=\"wp-block-paragraph\">P\u00e5 sidan om MDS 30A\u2013250A publiceras f\u00f6r n\u00e4rvarande leverant\u00f6rens referensv\u00e4rden f\u00f6r resistiva och induktiva belastningsf\u00f6rh\u00e5llanden.<\/p>\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table><thead><tr><th>Modellklass<\/th><th>Resistiv referens<\/th><th>Induktiv referens<\/th><\/tr><\/thead><tbody><tr><td>30A<\/td><td>27A<\/td><td>18A<\/td><\/tr><tr><td>60A<\/td><td>42A<\/td><td>36A<\/td><\/tr><tr><td>75A<\/td><td>50A<\/td><td>40A<\/td><\/tr><tr><td>100A<\/td><td>65A<\/td><td>45A<\/td><\/tr><tr><td>150A<\/td><td>100A<\/td><td>75A<\/td><\/tr><tr><td>200A<\/td><td>130A<\/td><td>100A<\/td><\/tr><tr><td>250A<\/td><td>175A<\/td><td>125A<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n<p class=\"wp-block-paragraph\">Detta \u00e4r leverant\u00f6rens referensv\u00e4rden som \u00e4r kopplade till de angivna modellerna.<\/p>\n\n\n<p class=\"wp-block-paragraph\">De b\u00f6r inte omvandlas till ett universellt f\u00f6rh\u00e5llande eller en storleksformel.<\/p>\n\n\n<p class=\"wp-block-paragraph\">Den h\u00e4r artikeln drar till exempel inte f\u00f6ljande slutsats:<\/p>\n\n\n<ul class=\"wp-block-list\">\n<li>en laststr\u00f6msmultiplikator<\/li>\n\n<li>en fast procentuell effektbegr\u00e4nsning<\/li>\n\n<li>en fast s\u00e4kerhetsmarginal<\/li>\n\n<li>en automatisk regel f\u00f6r modellval<\/li>\n<\/ul>\n\n\n<p class=\"wp-block-paragraph\">Anv\u00e4nd tabellen som referens och kontrollera den faktiska till\u00e4mpningen innan du v\u00e4ljer den exakta modulen.<\/p>\n\n<\/div>\n\n\n<div class=\"wp-block-group alignfull is-layout-constrained wp-container-core-group-is-layout-384c61b8 wp-block-group-is-layout-constrained\" style=\"padding-top:48px;padding-right:24px;padding-bottom:48px;padding-left:24px\">\n\n<h2 id=\"supplier-load-current-reference-data-300a-1200a-family\" class=\"wp-block-heading\">5. Referensdata f\u00f6r leverant\u00f6rens belastningsstr\u00f6m: 300 A\u20131 200 A-serien<\/h2>\n\n\n<p class=\"wp-block-paragraph\">P\u00e5 sidan om MDS 300A\u20131200A publiceras en motsvarande upps\u00e4ttning referensv\u00e4rden.<\/p>\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table><thead><tr><th>Modellklass<\/th><th>Resistiv referens<\/th><th>Induktiv referens<\/th><\/tr><\/thead><tbody><tr><td>300A<\/td><td>190A<\/td><td>135A<\/td><\/tr><tr><td>400A<\/td><td>250A<\/td><td>150A<\/td><\/tr><tr><td>500A<\/td><td>300A<\/td><td>180A<\/td><\/tr><tr><td>600A<\/td><td>340A<\/td><td>204A<\/td><\/tr><tr><td>800A<\/td><td>360A<\/td><td>216A<\/td><\/tr><tr><td>1000A<\/td><td>540A<\/td><td>324A<\/td><\/tr><tr><td>1200A<\/td><td>580A<\/td><td>340A<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n<p class=\"wp-block-paragraph\">Dessa v\u00e4rden b\u00f6r tolkas p\u00e5 samma s\u00e4tt:<\/p>\n\n\n<p class=\"wp-block-paragraph\">modellspecifika leverant\u00f6rsreferensuppgifter, inte en allm\u00e4n konstruktionsregel.<\/p>\n\n\n<p class=\"wp-block-paragraph\">Ber\u00e4kna inte ett f\u00f6rh\u00e5llande utifr\u00e5n en enda rad och till\u00e4mpa det sedan p\u00e5 andra MDS-modeller eller till\u00e4mpningar.<\/p>\n\n\n<p class=\"wp-block-paragraph\">Drifts- och kylf\u00f6rh\u00e5llandena spelar fortfarande en viktig roll.<\/p>\n\n<\/div>\n\n\n<div class=\"wp-block-group alignfull is-layout-constrained wp-container-core-group-is-layout-384c61b8 wp-block-group-is-layout-constrained\" style=\"padding-top:48px;padding-right:24px;padding-bottom:48px;padding-left:24px\">\n\n<h2 id=\"what-the-two-load-reference-tables-can-tell-you\" class=\"wp-block-heading\">6. Vad de tv\u00e5 belastningsreferenstabellerna kan ge dig f\u00f6r information<\/h2>\n\n\n<p class=\"wp-block-paragraph\">B\u00e5da familjerna tillhandah\u00e5ller referensinformation som kan hj\u00e4lpa en k\u00f6pare att utforma en mer specifik modellf\u00f6rfr\u00e5gan.<\/p>\n\n\n<p class=\"wp-block-paragraph\">De kan anv\u00e4ndas f\u00f6r att:<\/p>\n\n\n<ul class=\"wp-block-list\">\n<li>identifiera publicerade modellklasser<\/li>\n\n<li>granska leverant\u00f6rens referensuppgifter f\u00f6r en viss klass<\/li>\n\n<li>sammanst\u00e4lla ans\u00f6kningsuppgifter inf\u00f6r bekr\u00e4ftelsen<\/li>\n\n<li>identifiera fr\u00e5gor som b\u00f6r klarg\u00f6ras innan best\u00e4llning g\u00f6rs<\/li>\n<\/ul>\n\n\n<p class=\"wp-block-paragraph\">De b\u00f6r inte anv\u00e4ndas f\u00f6r att h\u00e4vda:<\/p>\n\n\n<ul class=\"wp-block-list\">\n<li>ett allm\u00e4nt samband mellan belastningsstr\u00f6m och modulens nominella v\u00e4rde<\/li>\n\n<li>garanterad l\u00e4mplighet f\u00f6r en viss maskin<\/li>\n\n<li>en automatisk regel f\u00f6r effektbegr\u00e4nsning<\/li>\n\n<li>en rekommenderad procentuell \u00f6verdimensionering<\/li>\n<\/ul>\n\n\n<p class=\"wp-block-paragraph\">Om ett projekt kr\u00e4ver tekniska ber\u00e4kningar m\u00e5ste dessa ber\u00e4kningar baseras p\u00e5 de faktiska elektriska och termiska f\u00f6rh\u00e5llandena samt verifierade uppgifter om enheterna.<\/p>\n\n<\/div>\n\n\n<div class=\"wp-block-group alignfull is-layout-constrained wp-container-core-group-is-layout-384c61b8 wp-block-group-is-layout-constrained\" style=\"padding-top:48px;padding-right:24px;padding-bottom:48px;padding-left:24px\">\n\n<h2 id=\"published-heatsink-references-also-differ\" class=\"wp-block-heading\">7. \u00c4ven de publicerade referenserna f\u00f6r kylfl\u00e4nsar skiljer sig \u00e5t<\/h2>\n\n\n<p class=\"wp-block-paragraph\">B\u00e5da MDS-produktsidorna inneh\u00e5ller information om kylfl\u00e4nsar med leverant\u00f6rsreferenser.<\/p>\n\n\n<p class=\"wp-block-paragraph\">MDS 30 A\u2013250 A<\/p>\n\n\n<p class=\"wp-block-paragraph\">Bland de publicerade referensgrupperna ing\u00e5r:<\/p>\n\n\n<p class=\"wp-block-paragraph\">30A\u2013100A<\/p>\n\n\n<p class=\"wp-block-paragraph\">125 \u00d7 95 \u00d7 50 mm referenskylfl\u00e4ns<\/p>\n\n\n<p class=\"wp-block-paragraph\">150A\u2013250A<\/p>\n\n\n<ul class=\"wp-block-list\">\n<li>150 \u00d7 100 \u00d7 80 mm referenskylfl\u00e4ns<\/li>\n\n<li>MDS 300A\u20131200A<\/li>\n<\/ul>\n\n\n<p class=\"wp-block-paragraph\">Bland de publicerade referensgrupperna ing\u00e5r:<\/p>\n\n\n<p class=\"wp-block-paragraph\">300A\u2013600A<\/p>\n\n\n<p class=\"wp-block-paragraph\">150 \u00d7 125 \u00d7 135 mm referenskylfl\u00e4ns<\/p>\n\n\n<p class=\"wp-block-paragraph\">800A\u20131200A<\/p>\n\n\n<p class=\"wp-block-paragraph\">250 \u00d7 141 \u00d7 135 mm referenskylfl\u00e4ns<\/p>\n\n\n<p class=\"wp-block-paragraph\">Dessa m\u00e5tt avser kylfl\u00e4nsen som anges av leverant\u00f6ren, inte m\u00e5tten p\u00e5 likriktarmodulen.<\/p>\n\n\n<p class=\"wp-block-paragraph\">Denna distinktion \u00e4r viktig.<\/p>\n\n\n<p class=\"wp-block-paragraph\">Anv\u00e4nd inte siffrorna som:<\/p>\n\n\n<ul class=\"wp-block-list\">\n<li>modulens f\u00f6rpackningsm\u00e5tt<\/li>\n\n<li>monteringsm\u00e5tt<\/li>\n\n<li>kr\u00e4vda m\u00e5tt p\u00e5 universalkylfl\u00e4nsen<\/li>\n\n<li>bevis p\u00e5 slutlig termisk prestanda<\/li>\n<\/ul>\n\n\n<p class=\"wp-block-paragraph\">Kylsystemet m\u00e5ste kontrolleras f\u00f6r den valda modellen och anv\u00e4ndningsomr\u00e5det.<\/p>\n\n<\/div>\n\n\n<div class=\"wp-block-group alignfull is-layout-constrained wp-container-core-group-is-layout-384c61b8 wp-block-group-is-layout-constrained\" style=\"padding-top:48px;padding-right:24px;padding-bottom:48px;padding-left:24px\">\n\n<h2 id=\"higher-current-class-does-not-establish-a-better-cooling-solution\" class=\"wp-block-heading\">8. En h\u00f6gre str\u00f6mklass inneb\u00e4r inte n\u00f6dv\u00e4ndigtvis en b\u00e4ttre kylningsl\u00f6sning<\/h2>\n\n\n<p class=\"wp-block-paragraph\">Det kan vara frestande att j\u00e4mf\u00f6ra de tv\u00e5 familjerna och dra slutsatsen att den med h\u00f6gre str\u00f6mstyrka automatiskt kr\u00e4ver en viss kylningsmetod.<\/p>\n\n\n<p class=\"wp-block-paragraph\">De nuvarande r\u00f6nen ger inte st\u00f6d f\u00f6r den generella slutsatsen.<\/p>\n\n\n<p class=\"wp-block-paragraph\">Den korrekta j\u00e4mf\u00f6relsen \u00e4r:<\/p>\n\n\n<ul class=\"wp-block-list\">\n<li>B\u00e5da f\u00f6retagen publicerar information om kylfl\u00e4nsreferenser<\/li>\n\n<li>dessa referensstorlekar varierar mellan olika modellgrupper<\/li>\n\n<li>Den slutliga termiska konfigurationen beror p\u00e5 den exakta modellen och anv\u00e4ndningsomr\u00e5det<\/li>\n<\/ul>\n\n\n<p class=\"wp-block-paragraph\">De nuvarande produktuppgifterna visar inte att varje variant av MDS 300A\u20131200A:<\/p>\n\n\n<ul class=\"wp-block-list\">\n<li>anv\u00e4nder samma kylningsmetod<\/li>\n\n<li>kr\u00e4ver vattenkylning<\/li>\n\n<li>anv\u00e4nder ett s\u00e4rskilt kylningsgr\u00e4nssnitt<\/li>\n\n<li>blir varmare \u00e4n alla modeller i intervallet 30\u2013250 A<\/li>\n<\/ul>\n\n\n<p class=\"wp-block-paragraph\">Kylningen b\u00f6r forts\u00e4tta att ing\u00e5 som en del av verifieringen av den exakta modellen.<\/p>\n\n<\/div>\n\n\n<div class=\"wp-block-group alignfull is-layout-constrained wp-container-core-group-is-layout-384c61b8 wp-block-group-is-layout-constrained\" style=\"padding-top:48px;padding-right:24px;padding-bottom:48px;padding-left:24px\">\n\n<h2 id=\"voltage-is-not-a-useful-side-by-side-comparison-yet\" class=\"wp-block-heading\">9. Sp\u00e4nning \u00e4r \u00e4nnu inte ett anv\u00e4ndbart j\u00e4mf\u00f6relsem\u00e5tt vid direkt j\u00e4mf\u00f6relse<\/h2>\n\n\n<p class=\"wp-block-paragraph\">De nuvarande produktsidorna inneh\u00e5ller inte tillr\u00e4ckligt med verifierad information p\u00e5 modellniv\u00e5 f\u00f6r att man ska kunna g\u00f6ra en tillf\u00f6rlitlig j\u00e4mf\u00f6relse av sp\u00e4nningsintervallen mellan dessa tv\u00e5 produktserier.<\/p>\n\n\n<p class=\"wp-block-paragraph\">F\u00f6r b\u00e5da:<\/p>\n\n\n<p class=\"wp-block-paragraph\">Version med exakt sp\u00e4nning \/ suffix: bekr\u00e4fta den valda modellen.<\/p>\n\n\n<p class=\"wp-block-paragraph\">D\u00e4rf\u00f6r b\u00f6r denna artikel inte h\u00e4vda f\u00f6ljande:<\/p>\n\n\n<ul class=\"wp-block-list\">\n<li>identiska sp\u00e4nningsintervall<\/li>\n\n<li>olika sp\u00e4nningsomr\u00e5den<\/li>\n\n<li>tillg\u00e5ng till sp\u00e4nning f\u00f6r alla sp\u00e4nningsniv\u00e5er<\/li>\n\n<li>ett s\u00e4rskilt sp\u00e4nningssuffix f\u00f6r varje str\u00f6mklass<\/li>\n<\/ul>\n\n\n<p class=\"wp-block-paragraph\">Sp\u00e4nningen b\u00f6r ist\u00e4llet anges i k\u00f6parens beg\u00e4ran om modellbekr\u00e4ftelse.<\/p>\n\n<\/div>\n\n\n<div class=\"wp-block-group alignfull is-layout-constrained wp-container-core-group-is-layout-384c61b8 wp-block-group-is-layout-constrained\" style=\"padding-top:48px;padding-right:24px;padding-bottom:48px;padding-left:24px\">\n\n<h2 id=\"mechanical-dimensions-cannot-yet-be-compared\" class=\"wp-block-heading\">10. De mekaniska m\u00e5tten kan \u00e4nnu inte j\u00e4mf\u00f6ras<\/h2>\n\n\n<p class=\"wp-block-paragraph\">De nuvarande sidorna inneh\u00e5ller inte heller tillr\u00e4ckligt med verifierad information f\u00f6r att man ska kunna j\u00e4mf\u00f6ra paketstorlekarna.<\/p>\n\n\n<p class=\"wp-block-paragraph\">F\u00f6r MDS 30A\u2013250A-serien \u00e5terst\u00e5r fortfarande att verifiera modellspecifik information om kapsling och ytterm\u00e5tt.<\/p>\n\n\n<p class=\"wp-block-paragraph\">F\u00f6r MDS 300A\u20131200A-serien inneh\u00e5ller den aktuella informationen motstridiga h\u00e4nvisningar till utformningen, som inte b\u00f6r l\u00f6sas genom gissningar.<\/p>\n\n\n<p class=\"wp-block-paragraph\">J\u00e4mf\u00f6r d\u00e4rf\u00f6r inte:<\/p>\n\n\n<ul class=\"wp-block-list\">\n<li>modulbredd<\/li>\n\n<li>modull\u00e4ngd<\/li>\n\n<li>modulens h\u00f6jd<\/li>\n\n<li>avst\u00e5nd mellan monteringsh\u00e5len<\/li>\n\n<li>terminalplatser<\/li>\n\n<li>vikt<\/li>\n\n<li>kylningsgr\u00e4nssnitt<\/li>\n<\/ul>\n\n\n<p class=\"wp-block-paragraph\">fr\u00e5n den aktuella artikelns uppgifter eller produktbilder.<\/p>\n\n\n<p class=\"wp-block-paragraph\">N\u00e4r passformen \u00e4r viktig, be om den verifierade ritningen f\u00f6r just den modellen.<\/p>\n\n<\/div>\n\n\n<div class=\"wp-block-group alignfull is-layout-constrained wp-container-core-group-is-layout-384c61b8 wp-block-group-is-layout-constrained\" style=\"padding-top:48px;padding-right:24px;padding-bottom:48px;padding-left:24px\">\n\n<h2 id=\"product-images-are-not-mechanical-drawings\" class=\"wp-block-heading\">11. Produktbilder \u00e4r inte tekniska ritningar<\/h2>\n\n\n<p class=\"wp-block-paragraph\">De befintliga produktbilderna fr\u00e5n RITOKS \u00e4r till hj\u00e4lp f\u00f6r att visuellt identifiera de olika produktserierna.<\/p>\n\n\n<p class=\"wp-block-paragraph\">De utg\u00f6r inte l\u00e4mpliga bevis f\u00f6r att fastst\u00e4lla:<\/p>\n\n\n<ul class=\"wp-block-list\">\n<li>modulens exakta m\u00e5tt<\/li>\n\n<li>terminaltilldelning<\/li>\n\n<li>pol\u00e4ritet vid anslutningen<\/li>\n\n<li>avst\u00e5nd mellan monteringsh\u00e5len<\/li>\n\n<li>sp\u00e4nning<\/li>\n\n<li>isolering<\/li>\n\n<li>intern krets<\/li>\n\n<li>certifiering<\/li>\n<\/ul>\n\n\n<p class=\"wp-block-paragraph\">En k\u00f6pare som beh\u00f6ver uppgifter om mekanisk integration b\u00f6r beg\u00e4ra verifierad dokumentation ist\u00e4llet f\u00f6r att skala eller tolka produktbilden.<\/p>\n\n<\/div>\n\n\n<div class=\"wp-block-group alignfull is-layout-constrained wp-container-core-group-is-layout-384c61b8 wp-block-group-is-layout-constrained\" style=\"padding-top:48px;padding-right:24px;padding-bottom:48px;padding-left:24px\">\n\n<h2 id=\"certification-and-standards-are-not-yet-a-comparison-point\" class=\"wp-block-heading\">12. Certifiering och standarder utg\u00f6r \u00e4nnu inte n\u00e5gon j\u00e4mf\u00f6relsegrund<\/h2>\n\n\n<p class=\"wp-block-paragraph\">Ingen av de granskade familjerna offentligg\u00f6r f\u00f6r n\u00e4rvarande tillr\u00e4ckligt med bevis f\u00f6r att man ska kunna g\u00f6ra en j\u00e4mf\u00f6relse av certifieringarna.<\/p>\n\n\n<p class=\"wp-block-paragraph\">Nuvarande status:<\/p>\n\n\n<p class=\"wp-block-paragraph\">MDS 30 A\u2013250 A<\/p>\n\n\n<ul class=\"wp-block-list\">\n<li>certifiering: ej offentliggjord<\/li>\n\n<li>standarder: ej publicerade<\/li>\n<\/ul>\n\n\n<p class=\"wp-block-paragraph\">MDS 300A\u20131200A<\/p>\n\n\n<ul class=\"wp-block-list\">\n<li>certifiering: ej offentliggjord<\/li>\n\n<li>standarder: ej publicerade<\/li>\n<\/ul>\n\n\n<p class=\"wp-block-paragraph\">Om certifiering eller marknadsgodk\u00e4nnande kr\u00e4vs, ange i f\u00f6rfr\u00e5gan exakt vilket dokument som beh\u00f6vs.<\/p>\n\n\n<p class=\"wp-block-paragraph\">Behandla inte:<\/p>\n\n\n<ul class=\"wp-block-list\">\n<li>produkttyp<\/li>\n\n<li>formulering i ans\u00f6kan<\/li>\n\n<li>leverant\u00f6rstabell<\/li>\n\n<li>produktbild<\/li>\n<\/ul>\n\n\n<p class=\"wp-block-paragraph\">som bevis p\u00e5 certifiering.<\/p>\n\n<\/div>\n\n\n<div class=\"wp-block-group alignfull is-layout-constrained wp-container-core-group-is-layout-384c61b8 wp-block-group-is-layout-constrained\" style=\"padding-top:48px;padding-right:24px;padding-bottom:48px;padding-left:24px\">\n\n<h2 id=\"neither-family-currently-provides-a-downloadable-datasheet\" class=\"wp-block-heading\">13. Inget av f\u00f6retagen tillhandah\u00e5ller f\u00f6r n\u00e4rvarande ett datablad som g\u00e5r att ladda ner<\/h2>\n\n\n<p class=\"wp-block-paragraph\">P\u00e5 de nuvarande produktsidorna finns det inget modellspecifikt datablad att ladda ner.<\/p>\n\n\n<p class=\"wp-block-paragraph\">Detta g\u00f6r att det \u00e4r \u00e4nnu viktigare att bekr\u00e4fta den exakta modellen f\u00f6r projekt som kr\u00e4ver:<\/p>\n\n\n<ul class=\"wp-block-list\">\n<li>m\u00e5ttritningar<\/li>\n\n<li>uppgifter om terminalen<\/li>\n\n<li>Bekr\u00e4ftelse av sp\u00e4nning\/version<\/li>\n\n<li>monteringsanvisningar<\/li>\n\n<li>termisk information<\/li>\n\n<li>certifieringsbevis<\/li>\n<\/ul>\n\n\n<p class=\"wp-block-paragraph\">Dessa b\u00f6r beg\u00e4ras f\u00f6r just den modell som \u00e4r aktuell.<\/p>\n\n<\/div>\n\n\n<div class=\"wp-block-group alignfull is-layout-constrained wp-container-core-group-is-layout-384c61b8 wp-block-group-is-layout-constrained\" style=\"padding-top:48px;padding-right:24px;padding-bottom:48px;padding-left:24px\">\n\n<h2 id=\"which-family-should-you-review-first\" class=\"wp-block-heading\">14. Vilken familj b\u00f6r du g\u00e5 igenom f\u00f6rst?<\/h2>\n\n\n<p class=\"wp-block-paragraph\">Det enklaste och s\u00e4kraste s\u00e4ttet att g\u00f6ra en \u00e5tskillnad \u00e4r det offentliggjorda str\u00f6mklassintervallet.<\/p>\n\n\n<p class=\"wp-block-paragraph\">L\u00e4s mer om MDS 30A\u2013250A-serien n\u00e4r<\/p>\n\n\n<p class=\"wp-block-paragraph\">Projektkravet faller inom en av de publicerade klasserna:<\/p>\n\n\n<p class=\"wp-block-paragraph\">30 \/ 60 \/ 75 \/ 100 \/ 150 \/ 200 \/ 250A<\/p>\n\n\n<p class=\"wp-block-paragraph\">Bekr\u00e4fta sedan:<\/p>\n\n\n<ul class=\"wp-block-list\">\n<li>version med exakt sp\u00e4nning<\/li>\n\n<li>ans\u00f6kan\/information om belastning<\/li>\n\n<li>kylsystem<\/li>\n\n<li>exakt modell<\/li>\n\n<li>n\u00f6dv\u00e4ndiga handlingar<\/li>\n\n<li>L\u00e4s mer om MDS 300A\u20131200A-serien n\u00e4r<\/li>\n<\/ul>\n\n\n<p class=\"wp-block-paragraph\">Projektkravet faller inom en av de publicerade klasserna:<\/p>\n\n\n<p class=\"wp-block-paragraph\">300 \/ 400 \/ 500 \/ 600 \/ 800 \/ 1000 \/ 1200A<\/p>\n\n\n<p class=\"wp-block-paragraph\">Utf\u00f6r sedan samma verifiering av den exakta modellen.<\/p>\n\n\n<p class=\"wp-block-paragraph\">Detta \u00e4r ett s\u00e4tt att begr\u00e4nsa urvalet av familjer f\u00f6r granskning, inte en slutgiltig metod f\u00f6r tekniskt urval.<\/p>\n\n<\/div>\n\n\n<div class=\"wp-block-group alignfull is-layout-constrained wp-container-core-group-is-layout-384c61b8 wp-block-group-is-layout-constrained\" style=\"padding-top:48px;padding-right:24px;padding-bottom:48px;padding-left:24px\">\n\n<h2 id=\"neither-family-is-universally-better\" class=\"wp-block-heading\">15. Ingen av familjerna \u00e4r \u00f6verlag b\u00e4ttre<\/h2>\n\n\n<p class=\"wp-block-paragraph\">En MDS-modul i 1200A-klassen b\u00f6r inte beskrivas som en b\u00e4ttre version av en modul i 100A-klassen.<\/p>\n\n\n<p class=\"wp-block-paragraph\">P\u00e5 samma s\u00e4tt b\u00f6r produktserien 30A\u2013250A inte automatiskt beskrivas som:<\/p>\n\n\n<ul class=\"wp-block-list\">\n<li>l\u00e4tt drift<\/li>\n\n<li>billigare<\/li>\n\n<li>mer effektiv<\/li>\n\n<li>l\u00e4ttare att kyla ner<\/li>\n<\/ul>\n\n\n<p class=\"wp-block-paragraph\">Och produktserien 300A\u20131200A b\u00f6r inte automatiskt beskrivas som:<\/p>\n\n\n<ul class=\"wp-block-list\">\n<li>f\u00f6r tung drift<\/li>\n\n<li>kraftfullare<\/li>\n\n<li>s\u00e4krare<\/li>\n\n<li>mer h\u00e5llbar<\/li>\n\n<li>b\u00e4ttre f\u00f6r kr\u00e4vande till\u00e4mpningar<\/li>\n<\/ul>\n\n\n<p class=\"wp-block-paragraph\">Dessa slutsatser kr\u00e4ver bevis som \u00e4nnu inte har offentliggjorts.<\/p>\n\n\n<p class=\"wp-block-paragraph\">Den meningsfulla skillnaden \u00e4r mycket enklare:<\/p>\n\n\n<p class=\"wp-block-paragraph\">De tv\u00e5 familjerna omfattar olika publicerade aktuella klasser.<\/p>\n\n<\/div>\n\n\n<div class=\"wp-block-group alignfull is-layout-constrained wp-container-core-group-is-layout-384c61b8 wp-block-group-is-layout-constrained\" style=\"padding-top:48px;padding-right:24px;padding-bottom:48px;padding-left:24px\">\n\n<h2 id=\"what-buyers-should-confirm-before-ordering-either-family\" class=\"wp-block-heading\">16. Vad k\u00f6pare b\u00f6r kontrollera innan de best\u00e4ller n\u00e5gon av modellerna<\/h2>\n\n\n<p class=\"wp-block-paragraph\">Oavsett vilken familj som granskas ska du kontrollera f\u00f6ljande:<\/p>\n\n\n<p class=\"wp-block-paragraph\">Nuvarande klass<\/p>\n\n\n<p class=\"wp-block-paragraph\">Vilken publicerad MDS-klass \u00f6verv\u00e4gs?<\/p>\n\n\n<p class=\"wp-block-paragraph\">Sp\u00e4nning<\/p>\n\n\n<p class=\"wp-block-paragraph\">Vilken exakt sp\u00e4nningsversion eller vilket suffix kr\u00e4vs?<\/p>\n\n\n<p class=\"wp-block-paragraph\">Ans\u00f6kan<\/p>\n\n\n<p class=\"wp-block-paragraph\">Vilka belastnings- och driftsf\u00f6rh\u00e5llanden g\u00e4ller?<\/p>\n\n\n<p class=\"wp-block-paragraph\">Kylning<\/p>\n\n\n<p class=\"wp-block-paragraph\">Vilken typ av v\u00e4rme- och kylningsl\u00f6sning kr\u00e4vs?<\/p>\n\n\n<p class=\"wp-block-paragraph\">Exakt modell<\/p>\n\n\n<p class=\"wp-block-paragraph\">Vilken fullst\u00e4ndig modellbeteckning kommer att anges?<\/p>\n\n\n<p class=\"wp-block-paragraph\">Tekniska uppgifter<\/p>\n\n\n<p class=\"wp-block-paragraph\">Beh\u00f6vs ritningar, m\u00e5tt eller monteringsanvisningar?<\/p>\n\n\n<p class=\"wp-block-paragraph\">Dokumentation<\/p>\n\n\n<p class=\"wp-block-paragraph\">Kr\u00e4vs det datablad, certifikat, testresultat eller andra tekniska dokument?<\/p>\n\n\n<p class=\"wp-block-paragraph\">Antal<\/p>\n\n\n<p class=\"wp-block-paragraph\">Hur stor m\u00e4ngd beh\u00f6vs?<\/p>\n\n\n<p class=\"wp-block-paragraph\">Den <a href=\"https:\/\/ritoks.com\/sv\/mds-bridge-rectifier-module-selection-guide\/\">V\u00e4gledning f\u00f6r val av MDS-brygglikriktarmodul<\/a> erbjuder ett mer omfattande urvalsf\u00f6rfarande.<\/p>\n\n<\/div>\n\n\n<div class=\"wp-block-group alignfull has-ast-global-color-4-background-color has-background is-layout-constrained wp-container-core-group-is-layout-8925a0ea wp-block-group-is-layout-constrained\" style=\"padding-top:56px;padding-right:24px;padding-bottom:56px;padding-left:24px\">\n\n<h2 id=\"frequently-asked-questions\" class=\"wp-block-heading\">Vanliga fr\u00e5gor<\/h2>\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Vad \u00e4r den st\u00f6rsta skillnaden mellan de tv\u00e5 MDS-familjerna?<\/summary>\n\n<p class=\"wp-block-paragraph\">Den tydligaste skillnaden som framg\u00e5r av deras publikationer g\u00e4ller str\u00f6mklassernas t\u00e4ckning. Den ena serien anger klasser fr\u00e5n 30 A till 250 A, medan den andra anger klasser fr\u00e5n 300 A till 1 200 A.<\/p>\n\n<\/details>\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Finns det n\u00e5gon publicerad MDS-klass mellan 250A och 300A?<\/summary>\n\n<p class=\"wp-block-paragraph\">Inte p\u00e5 dessa tv\u00e5 aktuella RITOKS-produktsidor. Det beskriver endast den nuvarande publicerade produktstrukturen och \u00e4r inte ett uttalande som g\u00e4ller hela marknaden.<\/p>\n\n<\/details>\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>\u00c4r 300A\u20131200A-serien b\u00e4ttre?<\/summary>\n\n<p class=\"wp-block-paragraph\">Nej. En h\u00f6gre str\u00f6mklass inneb\u00e4r inte n\u00f6dv\u00e4ndigtvis b\u00e4ttre verkningsgrad, s\u00e4kerhet, kylning eller l\u00e4mplighet.<\/p>\n\n<\/details>\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Kan jag v\u00e4lja en modell direkt fr\u00e5n tabellen \u00f6ver belastningsstr\u00f6m?<\/summary>\n\n<p class=\"wp-block-paragraph\">Tabellerna inneh\u00e5ller referensuppgifter om leverant\u00f6rer. De b\u00f6r inte omvandlas till en universell formel eller en automatisk urvalsregel.<\/p>\n\n<\/details>\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>\u00c4r de angivna storlekarna p\u00e5 kylfl\u00e4nsarna samma som modulens m\u00e5tt?<\/summary>\n\n<p class=\"wp-block-paragraph\">Nej. Det r\u00f6r sig om m\u00e5tt p\u00e5 kylfl\u00e4nsar enligt leverant\u00f6rens specifikationer och dessa b\u00f6r inte tolkas som m\u00e5tt p\u00e5 modulens h\u00f6lje.<\/p>\n\n<\/details>\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>\u00c4r sp\u00e4nningsalternativen desamma f\u00f6r b\u00e5da produktfamiljerna?<\/summary>\n\n<p class=\"wp-block-paragraph\">Den nuvarande informationen ger inte st\u00f6d f\u00f6r en exakt j\u00e4mf\u00f6relse av sp\u00e4nningen. Kontrollera vilken sp\u00e4nningsversion som g\u00e4ller f\u00f6r den valda modellen.<\/p>\n\n<\/details>\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Finns det m\u00e5tt och anslutningsritningar tillg\u00e4ngliga?<\/summary>\n\n<p class=\"wp-block-paragraph\">F\u00f6r n\u00e4rvarande finns ingen fullst\u00e4ndig och verifierad mekanisk information p\u00e5 modellniv\u00e5 publicerad p\u00e5 de tv\u00e5 produktsidorna. Beg\u00e4r den n\u00f6dv\u00e4ndiga ritningen innan den mekaniska integreringen p\u00e5b\u00f6rjas.<\/p>\n\n<\/details>\n\n<\/div>\n\n\n<div class=\"wp-block-group alignfull has-ast-global-color-5-background-color has-background is-layout-constrained wp-container-core-group-is-layout-8925a0ea wp-block-group-is-layout-constrained\" style=\"padding-top:56px;padding-right:24px;padding-bottom:56px;padding-left:24px\">\n\n<h2 id=\"compare-the-exact-mds-family-before-your-rfq\" class=\"wp-block-heading\">J\u00e4mf\u00f6r hela MDS-serien innan du beg\u00e4r en offert<\/h2>\n\n\n<p class=\"wp-block-paragraph\">B\u00f6rja med de redan publicerade kurserna:<\/p>\n\n\n<ul class=\"wp-block-list\">\n<li><strong>MDS 30 A\u2013250 A<\/strong> \u2192 30 \/ 60 \/ 75 \/ 100 \/ 150 \/ 200 \/ 250A<\/li>\n\n<li><strong>MDS 300A\u20131200A<\/strong> \u2192 300 \/ 400 \/ 500 \/ 600 \/ 800 \/ 1000 \/ 1200A<\/li>\n<\/ul>\n\n\n<p class=\"wp-block-paragraph\">Kontrollera sedan f\u00f6ljande:<\/p>\n\n\n<p class=\"wp-block-paragraph\">nuvarande klass \u2192 sp\u00e4nningsversion \u2192 anv\u00e4ndningsomr\u00e5de\/belastning \u2192 kylning \u2192 exakt modell \u2192 dokumentation<\/p>\n\n\n<p class=\"wp-block-paragraph\">innan du best\u00e4ller.<\/p>\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/ritoks.com\/sv\/product-category\/power-semiconductor-modules\/\">Visa krafthalvledarmoduler \u2192<\/a><\/li>\n\n<li><a href=\"https:\/\/ritoks.com\/sv\/product-category\/power-semiconductor-modules\/bridge-rectifier-modules\/\">Visa brygglikriktarmoduler \u2192<\/a><\/li>\n\n<li><a href=\"https:\/\/ritoks.com\/sv\/mds-bridge-rectifier-module-selection-guide\/\">L\u00e4s v\u00e4gledningen f\u00f6r val av MDS-brygglikriktarmoduler \u2192<\/a><\/li>\n\n<li><a href=\"https:\/\/ritoks.com\/sv\/products\/mds-three-phase-bridge-rectifier-30a-250a\/\">Visa MDS 30A\u2013250A-moduler \u2192<\/a><\/li>\n\n<li><a href=\"https:\/\/ritoks.com\/sv\/products\/mds-high-current-bridge-rectifier-300a-1200a\/\">Visa MDS 300A\u20131200A-moduler \u2192<\/a><\/li>\n<\/ul>\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-text-color has-background wp-element-button\" href=\"https:\/\/ritoks.com\/sv\/contact-us\/\" style=\"border-radius:6px;color:#ffffff;background-color:#1d5fbf\">Kontakta RITOKS \u2192 Bekr\u00e4fta din MDS-modell<\/a><\/div>\n<\/div>\n\n<\/div>","protected":false},"excerpt":{"rendered":"<p>RITOKS currently publishes two MDS three-phase bridge rectifier module families covering different current-class ranges: MDS 30A\u2013250A MDS 300A\u20131200A Both are [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ritoks_resource_detail_renderer":null,"ritoks_resource_product_cat_term_id":0,"footnotes":""},"categories":[66],"tags":[],"class_list":["post-762","post","type-post","status-publish","format-standard","hentry","category-power-semiconductors"],"acf":[],"spectra_blocks_featured_image_url":null,"spectra_blocks_author_info":{"display_name":"RITOKS","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/6d7d0fc73468198f994ab13ef6eb6558c53b6ed1ad86364d5165efe8bdf8eb4a?s=96&d=mm&r=g","author_link":"https:\/\/ritoks.com\/sv\/author\/dazzlingwqbgmail-com\/","description":""},"_links":{"self":[{"href":"https:\/\/ritoks.com\/sv\/wp-json\/wp\/v2\/posts\/762","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ritoks.com\/sv\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ritoks.com\/sv\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ritoks.com\/sv\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/ritoks.com\/sv\/wp-json\/wp\/v2\/comments?post=762"}],"version-history":[{"count":3,"href":"https:\/\/ritoks.com\/sv\/wp-json\/wp\/v2\/posts\/762\/revisions"}],"predecessor-version":[{"id":2179,"href":"https:\/\/ritoks.com\/sv\/wp-json\/wp\/v2\/posts\/762\/revisions\/2179"}],"wp:attachment":[{"href":"https:\/\/ritoks.com\/sv\/wp-json\/wp\/v2\/media?parent=762"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ritoks.com\/sv\/wp-json\/wp\/v2\/categories?post=762"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ritoks.com\/sv\/wp-json\/wp\/v2\/tags?post=762"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}