Hemen Bilgi Alın
RITOKS RTX-SSR-H single-phase solid-state relay with integrated heatsink

Power Semiconductor Modules · RTX-SSR-H

RTX-SSR-H Single-Phase Solid-State Relays with Integrated Heatsink

DIN-rail solid-state relays with integrated heatsink for configured single-phase AC load control. The RTX-SSR-H reference maps to a 480 VAC, 40 A, 4–32 VDC zero-crossing configuration; confirm the exact variant and thermal requirements before order.

Yük gerilimi480 VAC

Yük akımı40 A

Kontrol girişi4–32 VDC

SwitchingZero-crossing configuration

Ürün Genel Bakışı

DIN-rail solid-state relays with integrated heatsink for configured single-phase AC load control. The RTX-SSR-H reference maps to a 480 VAC, 40 A, 4–32 VDC zero-crossing configuration; confirm the exact variant and thermal requirements before order.

Temel Özellikler

  • Integrated heatsink for configured single-phase AC load switching
  • 480 VAC load-voltage reference with 40 A current rating
  • 4–32 VDC control input
  • Zero-crossing configuration; variant confirmation required

Mevcut Modeller / Konfigürasyonlar

Use these RITOKS configuration references for enquiry; confirm the exact specification before ordering.

RTX-SSR-H480 VAC / 40 A / 4–32 VDC / zero-crossing
RTX-SSR-H-ZZero-crossing variant; confirm thermal requirements
RTX-SSR-H-RRandom-turn-on variant by configuration

Teknik Özellikler

Yük gerilimi480 VAC
Yük akımı40 A
Kontrol girişi4–32 VDC
SwitchingZero-crossing configuration
Isı yönetimiIntegrated heatsink; confirm derating and airflow for the selected load
MontajDIN-rail or panel installation according to the selected housing
Yük türüConfigured single-phase AC load control
VariantConfirm zero-crossing or random-turn-on requirement before order

Başvurular

AI-generated conceptual application context. Confirm equipment fit, installation conditions and circuit requirements for the selected configuration.

AI-generated conceptual application scene: solid-state relay with heatsink controlling a resistive heater in an industrial cabinet

Resistive heating loads

Switch configured single-phase heaters after current, thermal and duty-cycle review.

Panel-mounted AC loads

Use the integrated heatsink housing where enclosure airflow and derating are confirmed.

Industrial automation cabinets

Coordinate the 4–32 VDC control signal with the selected zero-crossing variant.

Seçim İçin Doğrulanması Gereken Bilgiler

  • Load voltage, load current and AC load type
  • Control input and switching mode
  • Heatsink airflow, mounting and derating conditions
  • Required variant, quantity and destination

Sık Sorulan Sorular

What information is needed for a quotation?

Please include the exact configuration reference, quantity, destination and documentation requirements.

Fiyat Teklifi İsteyin

Tam model bilgisini, gerekli teknik özellikleri, adedi ve teslimat adresini bize iletin. Fiyat teklifi vermeden önce stok durumunu ve gerekli belgeleri teyit edeceğiz.

Ürün Bilgileri ve Fiyat Teklifi İsteyin

Model numaralarını, teknik özellikleri, miktarları ve teslimat adresi bilgilerini gönderin. Fiyat teklifi hazırlamadan önce stok durumunu teyit edeceğiz.

Sayfanın Başına Git