Hemen Bilgi Alın
RITOKS RTX-PCB three-phase pin-type comb busbar on a white background

Power Distribution Components · RTX-PCB

RTX-PCB 3-Phase Pin-Type Comb Busbars

Three-phase pin-type comb busbars for linking rows of DIN-rail miniature circuit breakers, in brass or red-copper sections rated 24A to 150A.

Phases3P pin type

Mevcut24A–150A by section

Orkestra şefiBrass or red copper

GerilimAC220V, supplier-listed

Ürün Genel Bakışı

RTX-PCB comb busbars replace looped wiring between MCBs. The pins plug into breaker terminals and the insulated carrier keeps phases separated. The current rating depends on conductor material and cross-section, so select by the table rather than by length.

Temel Özellikler

  • Pin-type connection to MCB terminals
  • Brass sections 24A–38A
  • Red-copper sections 32A–150A
  • Insulated carrier for 3-phase rows

Mevcut Modeller / Konfigürasyonlar

Use these RITOKS configuration references for enquiry; confirm the exact specification before ordering.

RITOKS referansıOrkestra şefiSection (mm)Anma akımı
RTX-PCB3-B10Brass1.0 × 524A
RTX-PCB3-B12Brass1.2 × 530A
RTX-PCB3-B14Brass1.4 × 538A
RTX-PCB3-C10Red copper1.0 × 532A
RTX-PCB3-C12Red copper1.2 × 535A
RTX-PCB3-C14Red copper1.4 × 540A
RTX-PCB3-C17Red copper1.7 × 550A
RTX-PCB3-C147Red copper1.4 × 763A
RTX-PCB3-C177Red copper1.7 × 780A
RTX-PCB3-C179Red copper1.7 × 990A
RTX-PCB3-C209Red copper2.0 × 9100A
RTX-PCB3-C309Red copper3.0 × 9150A

Teknik Özellikler

Ürün türüPin-type comb busbar
Phases3P
Orkestra şefiBrass or red copper
Anma akımı24A–150A by section
Nominal gerilimAC220V (supplier-listed)
KurulumPlug-in to breaker terminals
Length and pitchConfirm with RITOKS before ordering

Başvurular

AI-generated conceptual application context. Confirm equipment fit, installation conditions and circuit requirements for the selected configuration.

AI-generated scene of a comb busbar linking a row of miniature circuit breakers

Final distribution boards

Link rows of 3-phase MCBs in building distribution boards.

Machine control panels

Feed groups of branch breakers from one incoming device.

Panel builder kits

Speed up repeat panel wiring with cut-to-length busbars.

Seçim İçin Doğrulanması Gereken Bilgiler

  • Breaker type and terminal design
  • Number of poles and module pitch
  • Required current and conductor material
  • Length, end caps and quantity

Sık Sorulan Sorular

Which breakers fit the pin busbar?

Pin-type busbars fit breakers with compatible pin terminals. Confirm the breaker model and pitch.

Why does current differ by section?

Rating depends on conductor material and cross-section; red copper and larger sections carry more current.

Fiyat Teklifi İsteyin

Tam model bilgisini, gerekli teknik özellikleri, adedi ve teslimat adresini bize iletin. Fiyat teklifi vermeden önce stok durumunu ve gerekli belgeleri teyit edeceğiz.

Ürün Bilgileri ve Fiyat Teklifi İsteyin

Model numaralarını, teknik özellikleri, miktarları ve teslimat adresi bilgilerini gönderin. Fiyat teklifi hazırlamadan önce stok durumunu teyit edeceğiz.

Sayfanın Başına Git