{"id":1071,"date":"2026-09-19T14:39:39","date_gmt":"2026-09-19T14:39:39","guid":{"rendered":"https:\/\/ritoks.com\/?p=1071"},"modified":"2026-10-04T06:58:18","modified_gmt":"2026-10-04T06:58:18","slug":"ac-contactor-selection-guide","status":"publish","type":"post","link":"https:\/\/ritoks.com\/tr\/ac-contactor-selection-guide\/","title":{"rendered":"AC Kontakt\u00f6r Se\u00e7im K\u0131lavuzu: Y\u00fck \u015eartlar\u0131, Bobin Gerilimi ve Yard\u0131mc\u0131 Kontakt\u00f6rler"},"content":{"rendered":"<p class=\"wp-block-paragraph\">Bir AC kontakt\u00f6r\u00fcn\u00fcn se\u00e7imi, tek bir ak\u0131m de\u011ferinin uygunlu\u011funu kontrol etmekten daha fazlas\u0131n\u0131 gerektirir. Anahtarlanacak y\u00fck, kullan\u0131m kategorisi, \u00e7al\u0131\u015fma gerilimi, gerekli \u00e7al\u0131\u015fma ak\u0131m\u0131, bobin\/kontrol beslemesi, ana kutuplar, yard\u0131mc\u0131 kontaklar, beklenen anahtarlama s\u0131kl\u0131\u011f\u0131 ve destekleyici belgeler; t\u00fcm bunlar, kesin konfig\u00fcrasyonu etkiler.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Bu k\u0131lavuz, end\u00fcstriyel al\u0131c\u0131lara kan\u0131ta dayal\u0131 bir \u015fartname haz\u0131rlama s\u00fcreci sunmaktad\u0131r. Bu k\u0131lavuz, ayr\u0131nt\u0131l\u0131 \u00fcr\u00fcn teknik \u00f6zellik belgesinin, motor kontrol\u00fc koordinasyon \u00e7al\u0131\u015fmas\u0131n\u0131n, iletken boyutland\u0131rmas\u0131n\u0131n, k\u0131sa devre koruma se\u00e7iminin veya kurulum talimatlar\u0131n\u0131n yerini almaz.<\/p>\n\n\n\n<figure data-spectra-id=\"spectra-b0b89400-d806-4f4b-8ef7-701acec7ef4d\" class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" height=\"1200\" width=\"1200\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/zs3tf-series-ac-contactor-draft-preview.webp\" alt=\"Motor ve devre kontrol\u00fc i\u00e7in ZS3TF serisi end\u00fcstriyel AC kontakt\u00f6r\" class=\"wp-image-898\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/zs3tf-series-ac-contactor-draft-preview.webp 1200w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/zs3tf-series-ac-contactor-draft-preview-300x300.webp 300w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/zs3tf-series-ac-contactor-draft-preview-100x100.webp 100w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/zs3tf-series-ac-contactor-draft-preview-600x600.webp 600w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/zs3tf-series-ac-contactor-draft-preview-1024x1024.webp 1024w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/zs3tf-series-ac-contactor-draft-preview-150x150.webp 150w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/zs3tf-series-ac-contactor-draft-preview-768x768.webp 768w\" sizes=\"auto, (max-width: 1200px) 100vw, 1200px\" \/><figcaption class=\"wp-element-caption\">ZS3TF end\u00fcstriyel AC kontakt\u00f6r serisi yay\u0131nlanm\u0131\u015ft\u0131r. Kesin konfig\u00fcrasyon i\u00e7in model de\u011ferleri, bobin gereksinimleri ve yard\u0131mc\u0131 kontaklar teyit edilmelidir.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">AC Kontakt\u00f6r Se\u00e7imi: \u00d6zet Bilgi<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A useful contactor inquiry separates the power circuit, control circuit and auxiliary functions. Schneider Electric&#8217;s <a href=\"https:\/\/www.se.com\/uk\/en\/faqs\/FA142452\/\" target=\"_blank\" rel=\"noopener\">kontakt\u00f6r teknik \u00f6zellikleri k\u0131lavuzu<\/a> ana kontaklar\u0131, yard\u0131mc\u0131 kontaklar\u0131 ve bobini tan\u0131mlanmas\u0131 gereken ayr\u0131 elemanlar olarak belirler. Bu <a href=\"https:\/\/productinfo.se.com\/tesysgigainstallationguide\/tesys-giga-series-giga-contactors-and-giga-thermal-overload-relays-installation-guide\/English\/TeSys%E2%84%A2%20Giga%20Series%20Giga%20Contactors%20and%20Giga%20Thermal%20Overload%20Relays%20Installation%20Guide_0000447511.xml\/%24\/PanGu_LoadsCPT_0000507717\" target=\"_blank\" rel=\"noopener\">kullan\u0131m kategorisi belgeleri<\/a> ayr\u0131ca g\u00f6rev de\u011fi\u015ftirmenin neden \u00f6nemli oldu\u011funu da g\u00f6stermektedir. Bu kaynaklar yaln\u0131zca genel terminolojiyi desteklemektedir; bu kaynaklardaki model \u00f6zellikleri, aksesuarlar ve sertifikalar RITOKS \u00fcr\u00fcn verileri de\u011fildir.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Se\u00e7im giri\u015fi<\/th><th>Neyin tan\u0131mlanmas\u0131 veya do\u011frulanmas\u0131 gerekti\u011fi<\/th><\/tr><\/thead><tbody>\n<tr><td>Y\u00fck ve anahtarlama g\u00f6revi<\/td><td>Y\u00fck\u00fc ve \u00e7al\u0131\u015fma s\u0131ras\u0131n\u0131 a\u00e7\u0131klay\u0131n; yetkili belgelerden ge\u00e7erli kullan\u0131m kategorisini belirleyin.<\/td><\/tr>\n<tr><td>G\u00fc\u00e7 devresi gerilimi<\/td><td>Anahtarlamal\u0131 devrenin \u00e7al\u0131\u015fma gerilimini ve faz d\u00fczenini belirtiniz.<\/td><\/tr>\n<tr><td>\u00c7al\u0131\u015fma ak\u0131m\u0131 \/ motor \u00e7\u0131k\u0131\u015f\u0131<\/td><td>\u0130stenen kullan\u0131m kategorisi ve gerilim i\u00e7in yay\u0131nlanan de\u011ferleri kullan\u0131n; ba\u015fka bir kullan\u0131m t\u00fcr\u00fc veya gerilimi kullanmay\u0131n.<\/td><\/tr>\n<tr><td>Bobin\/kontrol beslemesi<\/td><td>Uygun oldu\u011fu durumlarda, AC veya DC bobin beslemesini, gerilimi ve frekans\u0131 belirtiniz.<\/td><\/tr>\n<tr><td>Ana direkler<\/td><td>Devre mimarisinin gerektirdi\u011fi say\u0131y\u0131 ve normal durumu do\u011frulay\u0131n.<\/td><\/tr>\n<tr><td>Yard\u0131mc\u0131 kontaklar<\/td><td>Gerekli NO\/NC kontaklar\u0131n\u0131 ve varsa zamanlama veya sinyal gerekliliklerini belirtin.<\/td><\/tr>\n<tr><td>\u00c7al\u0131\u015fma frekans\u0131<\/td><td>Se\u00e7imi etkileyen saat ba\u015f\u0131na beklenen i\u015flem say\u0131s\u0131n\u0131 ve g\u00f6rev d\u00f6ng\u00fcs\u00fcn\u00fc belirleyin.<\/td><\/tr>\n<tr><td>\u00c7evre ve muhafaza<\/td><td>Belirli bir modelin incelenmesi i\u00e7in ortam, montaj, muhafaza ve kurulum ko\u015fullar\u0131n\u0131 belirtin.<\/td><\/tr>\n<tr><td>\u0130lgili cihazlar<\/td><td>Do\u011frulanm\u0131\u015f koordinasyon gerektiren a\u015f\u0131r\u0131 y\u00fck r\u00f6lelerini, motor devre ba\u015flat\u0131c\u0131lar\u0131n\u0131, MPCB\u2019leri, kilitleme sistemlerini veya di\u011fer aksesuarlar\u0131 belirleyin.<\/td><\/tr>\n<tr><td>Belgeler<\/td><td>\u0130lgili \u00fcr\u00fcn\u00fcn teknik veriler sayfas\u0131n\u0131, sipari\u015f kodunu, boyut \u00e7izimini, kablolama bilgilerini ve gerekli sertifikalar\u0131 talep edin.<\/td><\/tr>\n<\/tbody><\/table><\/figure>\n\n\n\n<figure data-spectra-id=\"spectra-42230def-a893-4d5e-b4c2-dd6075733792\" class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" height=\"2560\" width=\"1264\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-contactor-selection-workflow-cropped-scaled.png\" alt=\"Y\u00fck g\u00f6revinden ba\u015flay\u0131p kesin modele dayal\u0131 teklif talebi haz\u0131rl\u0131\u011f\u0131na kadar uzanan alt\u0131 a\u015famal\u0131 AC kontakt\u00f6r se\u00e7imi do\u011frulama s\u00fcreci\" class=\"wp-image-1137\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-contactor-selection-workflow-cropped-scaled.png 1264w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-contactor-selection-workflow-cropped-scaled-600x1215.png 600w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-contactor-selection-workflow-cropped-148x300.png 148w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-contactor-selection-workflow-cropped-506x1024.png 506w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-contactor-selection-workflow-cropped-768x1556.png 768w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-contactor-selection-workflow-cropped-758x1536.png 758w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-contactor-selection-workflow-cropped-1011x2048.png 1011w\" sizes=\"auto, (max-width: 1264px) 100vw, 1264px\" \/><figcaption class=\"wp-element-caption\">Bir AC kontakt\u00f6r talebini d\u00fczenlemek i\u00e7in bu alt\u0131 a\u015famal\u0131 i\u015f ak\u0131\u015f\u0131n\u0131 kullan\u0131n. Bu i\u015f ak\u0131\u015f\u0131, bir modeli otomatik olarak se\u00e7mez; eksik girilen bilgiler, ilgili teknik \u00f6zellik belgesiyle kar\u015f\u0131la\u015ft\u0131r\u0131larak kontrol edilmeli veya tedarik\u00e7iye teyit edilmelidir.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">1. Y\u00fck ve Anahtarlama G\u00f6revini Tan\u0131mlay\u0131n<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u00d6ncelikle kontakt\u00f6r\u00fcn hangi y\u00fck\u00fc anahtarlayaca\u011f\u0131 ve nas\u0131l \u00e7al\u0131\u015faca\u011f\u0131 ile ba\u015flay\u0131n. Diren\u00e7li y\u00fck, normal motor \u00e7al\u0131\u015ft\u0131rma, y\u00f6n de\u011fi\u015ftirme, t\u0131kanma, ad\u0131m ad\u0131m hareket veya ba\u015fka bir anahtarlama dizisi, ana kontaklara farkl\u0131 y\u00fckler getirebilir. Belirli bir kullan\u0131m kategorisi i\u00e7in belirtilen kontakt\u00f6r de\u011ferleri, her y\u00fck i\u00e7in evrensel bir ak\u0131m de\u011feri olarak kabul edilmemelidir.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For motor-control work, AC-3 and AC-4 are not interchangeable labels. Official manufacturer documentation describes AC-3 around normal squirrel-cage motor starting and switching off during running, while AC-4 covers more severe operations such as plugging, inching or reversing. Record the actual operating sequence, then use the exact manufacturer&#8217;s rating table for that duty.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Yay\u0131nlanan ZS3TF sayfas\u0131nda, 380 V'ta modele g\u00f6re hem AC-3 hem de AC-4 ak\u0131m alanlar\u0131 verilmektedir. Bunlar ayr\u0131 veri s\u00fctunlar\u0131d\u0131r. Daha b\u00fcy\u00fck olan AC-3 de\u011ferinden bir AC-4 uygulamas\u0131 se\u00e7meyin veya modeller aras\u0131nda de\u011fer kopyalamay\u0131n.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">2. \u00c7al\u0131\u015fma Ak\u0131m\u0131n\u0131 ve Gerilimini Tam \u00c7al\u0131\u015fma Ko\u015fullar\u0131na Uygun Hale Getirin<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u00c7al\u0131\u015fma ak\u0131m\u0131, \u00e7al\u0131\u015fma gerilimi ve kullan\u0131m kategorisi ile birlikte de\u011ferlendirilmelidir. Motor \u00e7\u0131k\u0131\u015f de\u011feri de kaynakta belirtilen gerilim ve model ko\u015fullar\u0131na ba\u011fl\u0131d\u0131r. Tek bir ak\u0131m de\u011feri, farkl\u0131 gerilimler, y\u00fckler veya anahtarlama dizileri aras\u0131nda uygunlu\u011fu belirleyemez.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Mevcut <a href=\"https:\/\/ritoks.com\/tr\/products\/zs3tf-series-industrial-ac-contactors-9a-400a\/\">ZS3TF end\u00fcstriyel AC kontakt\u00f6r serisi<\/a> 380 V'ta 9 A ila 400 A AC-3 nominal \u00e7al\u0131\u015fma ak\u0131m\u0131n\u0131 kapsayan 17 adet genel model listelenmi\u015ftir. Her sat\u0131rda ayr\u0131ca ilgili AC-4 ak\u0131m\u0131, 400\/380 V'taki motor \u00e7\u0131k\u0131\u015f\u0131 ve nominal yal\u0131t\u0131m gerilimi de belirtilmi\u015ftir. Bu sat\u0131rlar\u0131 yaln\u0131zca ilk model elemesi i\u00e7in kullan\u0131n; ard\u0131ndan sipari\u015f edilebilir tam konfig\u00fcrasyonu teyit edin.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Anma yal\u0131t\u0131m gerilimi, \u00e7al\u0131\u015fma geriliminin, kullan\u0131m kategorisinin veya modele \u00f6zg\u00fc \u00e7al\u0131\u015fma de\u011ferlerinin yerine ge\u00e7mez. Teklif talebinde ve teknik incelemede bu alanlar\u0131 birbirinden ayr\u0131 tutun.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">3. G\u00fc\u00e7 devresi gerilimini bobin geriliminden ay\u0131r\u0131n<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Bobin, kontakt\u00f6r mekanizmas\u0131na enerji verirken, ana kutuplar g\u00fc\u00e7 devresini anahtarlar. Bu nedenle bobin, anahtarlanan devreden farkl\u0131 bir gerilime ihtiya\u00e7 duyabilir. Kontrol beslemesinin AC mi yoksa DC mi oldu\u011funu, nominal gerilimini ve AC bobin s\u00f6z konusu oldu\u011funda ilgili frekans\u0131 belirtiniz.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Mevcut ZS3TF genel sayfas\u0131nda, bobin gerilimi sipari\u015f tablosunun tam hali yay\u0131nlanmamaktad\u0131r. Bu sayfada, mevcut t\u00fcm nominal bobin se\u00e7enekleri yay\u0131nlanmaks\u0131z\u0131n, yaln\u0131zca ZS3TF46 ile ZS3TF56 aras\u0131ndaki modeller i\u00e7in bobin gerilimi tolerans\u0131 listelenmektedir. Al\u0131c\u0131lar, gerekli kontrol gerilimini belirtmeli ve g\u00fc\u00e7 devresi de\u011ferlerinden \u00e7\u0131kar\u0131mda bulunmak yerine, kesin model sonekini veya sipari\u015f kodunu talep etmelidir.<\/p>\n\n\n\n<figure data-spectra-id=\"spectra-562e2798-40b5-413e-a7da-b241942e7dcf\" class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" height=\"1080\" width=\"1440\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-contactor-functional-relationship-cropped.png\" alt=\"Bir AC kontakt\u00f6r\u00fcn ana devresini, kontrol bobinini ve yard\u0131mc\u0131 kontaklar\u0131n\u0131 g\u00f6steren kavramsal \u015fema\" class=\"wp-image-1138\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-contactor-functional-relationship-cropped.png 1440w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-contactor-functional-relationship-cropped-600x450.png 600w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-contactor-functional-relationship-cropped-300x225.png 300w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-contactor-functional-relationship-cropped-1024x768.png 1024w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-contactor-functional-relationship-cropped-768x576.png 768w\" sizes=\"auto, (max-width: 1440px) 100vw, 1440px\" \/><figcaption class=\"wp-element-caption\">Bu, yaln\u0131zca kavramsal ve i\u015flevsel bir ili\u015fkiyi g\u00f6sterir; bir kablo \u015femas\u0131 de\u011fildir. Kesin kontak d\u00fczeni, bobin beslemesi, teknik \u00f6zellikler ve ba\u011flant\u0131 detaylar\u0131, ilgili teknik \u00f6zellik belgesiyle kar\u015f\u0131la\u015ft\u0131r\u0131larak do\u011frulanmal\u0131 veya tedarik\u00e7iye dan\u0131\u015f\u0131lmal\u0131d\u0131r.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">4. Ana Kutuplar\u0131 ve Yard\u0131mc\u0131 Kontaklar\u0131 Do\u011frulay\u0131n<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Ana kutuplar, anahtarlanan y\u00fck\u00fc ta\u015f\u0131r. Yard\u0131mc\u0131 kontaklar genellikle kontrol, g\u00f6sterge, kilitleme veya geri bildirim i\u015flevleri i\u00e7in kullan\u0131l\u0131r. Gerekli ana kutup say\u0131s\u0131n\u0131 ve gerekli normalde a\u00e7\u0131k veya normalde kapal\u0131 yard\u0131mc\u0131 kontaklar\u0131 ayr\u0131 ayr\u0131 belirtin.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">ZS3TF katalo\u011fundaki bilgiler, en fazla 2NO + 2NC\u2019ye kadar olan bir aile d\u00fczeyinde yard\u0131mc\u0131 d\u00fczenleme beyan\u0131n\u0131 desteklemektedir; ancak bu d\u00fczenleme, her bir piyasada bulunan modele kar\u015f\u0131l\u0131k gelmemektedir. Bu beyan, her modelin 2NO + 2NC i\u00e7erdi\u011fi y\u00f6n\u00fcnde bir taahh\u00fct olarak yorumlanmamal\u0131d\u0131r. Gerekli d\u00fczenlemeyi belirtin ve konfig\u00fcrasyon onay\u0131 isteyin.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">5. Anahtarlama S\u0131kl\u0131\u011f\u0131n\u0131, Dayan\u0131kl\u0131l\u0131\u011f\u0131 ve Ortam\u0131 Kontrol Edin<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">S\u0131k s\u0131k \u00e7al\u0131\u015ft\u0131r\u0131lan uygulamalar, sadece ak\u0131m kontrol\u00fcnden daha fazlas\u0131n\u0131 gerektirir. Saatte beklenen \u00e7al\u0131\u015fma say\u0131s\u0131, elektriksel y\u00fck, mekanik \u00e7al\u0131\u015fma, ortam ko\u015fullar\u0131, muhafaza s\u0131cakl\u0131\u011f\u0131 ve montaj d\u00fczeni, kesin se\u00e7imi etkileyebilir. \u00dcr\u00fcn ailesinin tamam\u0131 i\u00e7in tek bir varsay\u0131m uygulamak yerine, modele \u00f6zg\u00fc s\u0131n\u0131r de\u011ferlerini talep edin.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ayr\u0131nt\u0131l\u0131 anahtarlama frekans\u0131 ve dayan\u0131kl\u0131l\u0131k de\u011ferleri, yaln\u0131zca ZS3TF46 ile ZS3TF56 aras\u0131ndaki modeller i\u00e7in ZS3TF sayfas\u0131nda yay\u0131nlanmaktad\u0131r. Daha k\u00fc\u00e7\u00fck boyutlu halka a\u00e7\u0131k modellerde ayn\u0131 kapsaml\u0131 performans tablosu bulunmamaktad\u0131r. Eksik de\u011ferler, kesin belgeler elde edilene kadar doldurulmamal\u0131d\u0131r.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">6. Anahtar, A\u015f\u0131r\u0131 Y\u00fck Korumas\u0131 ve Devre Korumas\u0131n\u0131 Birbirinden Ay\u0131r\u0131n<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Bir kontakt\u00f6r, kontroll\u00fc anahtarlama sa\u011flar; otomatik a\u015f\u0131r\u0131 y\u00fck veya k\u0131sa devre korumas\u0131 olarak tan\u0131mlanmamal\u0131d\u0131r. A <a href=\"https:\/\/ritoks.com\/tr\/product-category\/industrial-power-switching\/thermal-overload-relays\/\">termal a\u015f\u0131r\u0131 y\u00fck r\u00f6lesi<\/a>, bir motor koruma devre kesicisi ile bir \u00fcst devre koruma cihaz\u0131n\u0131n i\u015flevleri ve kan\u0131t gereklilikleri birbirinden farkl\u0131d\u0131r.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Bu koruma rollerini ayr\u0131nt\u0131l\u0131 bir \u015fekilde kar\u015f\u0131la\u015ft\u0131rmak i\u00e7in \u015fu yaz\u0131y\u0131 okuyun: <a href=\"https:\/\/ritoks.com\/tr\/mpcb-vs-overload-relay-vs-mcb\/\">MPCB, termal a\u015f\u0131r\u0131 y\u00fck r\u00f6lesi ve MCB kar\u015f\u0131la\u015ft\u0131rmas\u0131<\/a>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Kapal\u0131 bir <a href=\"https:\/\/ritoks.com\/tr\/product-category\/industrial-power-switching\/motor-starters\/\">motor devre ba\u015flat\u0131c\u0131<\/a> Bir montajda birden fazla kontrol ve koruma bile\u015fenini bir araya getirebilir, ancak kesin mimari h\u00e2l\u00e2 teyit edilmelidir. Yay\u0131nlanm\u0131\u015f RITOKS \u00f6rnekleri aras\u0131nda \u015funlar yer al\u0131r: <a href=\"https:\/\/ritoks.com\/tr\/products\/zsle1-d-enclosed-magnetic-motor-starter\/\">ZSLE1-D manyetik motor devre ba\u015flat\u0131c\u0131<\/a> ve <a href=\"https:\/\/ritoks.com\/tr\/products\/zs3ru-thermal-overload-relays-0-11a-100a\/\">ZS3RU termal a\u015f\u0131r\u0131 y\u00fck r\u00f6leleri<\/a>. Ayn\u0131 motor kontrol grubunda yer almalar\u0131, se\u00e7ilen bir ZS3TF kontakt\u00f6rle uyumluluklar\u0131n\u0131 kan\u0131tlamaz.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Proje ayr\u0131ca dal veya besleme hatt\u0131 korumas\u0131na ihtiya\u00e7 duyuyorsa, ayr\u0131 olarak haz\u0131rlanan <a href=\"https:\/\/ritoks.com\/tr\/ac-mcb-selection-guide\/\">AC MCB se\u00e7im k\u0131lavuzu<\/a>. Koordinasyon, k\u0131sa devre korumas\u0131 ve kombinasyon de\u011ferleri i\u00e7in \u00fcreticinin kesin belgeleri gereklidir ve bunlar yaln\u0131zca bile\u015fen adlar\u0131na dayan\u0131larak belirlenmemelidir.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Yay\u0131nlanan RITOKS AC Kontakt\u00f6r Serisi<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u015eu <a href=\"https:\/\/ritoks.com\/tr\/product-category\/industrial-power-switching\/ac-contactors\/\">AC Kontakt\u00f6rleri kategorisi<\/a> \u015eu anda end\u00fcstriyel devre anahtarlama ve AC motor kontrol\u00fc i\u00e7in ZS3TF serisini sunmaktad\u0131r. A\u015fa\u011f\u0131daki tablo, bir model se\u00e7me arac\u0131 de\u011fil, bir eleme \u00f6zetidir.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Yay\u0131nlanan alan<\/th><th>ZS3TF kan\u0131t\u0131<\/th><th>Nas\u0131l kullan\u0131l\u0131r?<\/th><\/tr><\/thead><tbody>\n<tr><td>Genel model k\u00fcmesi<\/td><td>17 model<\/td><td>Tam model sat\u0131r\u0131na g\u00f6re aday listesini olu\u015fturun; tam sipari\u015f kodunu isteyin.<\/td><\/tr>\n<tr><td>380 V'taki AC-3 ak\u0131m\u0131<\/td><td>9 A ila 400 A, modele ba\u011fl\u0131 olarak<\/td><td>Yaln\u0131zca belirtilen gerilim ve \u00e7al\u0131\u015fma ko\u015fullar\u0131nda kullan\u0131n.<\/td><\/tr>\n<tr><td>380 V'ta AC-4 ak\u0131m\u0131<\/td><td>model taraf\u0131ndan yay\u0131nland\u0131<\/td><td>\u0130lgili a\u011f\u0131r hizmet \u015fart\u0131 i\u00e7in AC-4 s\u00fctununu kullan\u0131n; AC-3 ile de\u011fi\u015ftirmeyin.<\/td><\/tr>\n<tr><td>Motor g\u00fcc\u00fc<\/td><td>model taraf\u0131ndan 400\/380 V'ta yay\u0131nlanm\u0131\u015ft\u0131r<\/td><td>De\u011feri, tam modeline ve voltaj ba\u011flam\u0131na ba\u011fl\u0131 tutun.<\/td><\/tr>\n<tr><td>Nominal yal\u0131t\u0131m gerilimi<\/td><td>690 V veya 1000 V, modele ba\u011fl\u0131 olarak<\/td><td>Bunu \u00e7al\u0131\u015fma gerilimi olarak de\u011ferlendirmeyin.<\/td><\/tr>\n<tr><td>Bobin se\u00e7enekleri<\/td><td>Yay\u0131nlanmam\u0131\u015f tam nominal se\u00e7enekler<\/td><td>Gerekli bobin tedarikini sa\u011flay\u0131n ve onay isteyin.<\/td><\/tr>\n<tr><td>Yard\u0131mc\u0131 kontaklar<\/td><td>2NO + 2NC\u2019ye kadar olan aile devre \u015femas\u0131<\/td><td>Pakete dahil olan veya iste\u011fe ba\u011fl\u0131 olan se\u00e7eneklerin tam olarak neler oldu\u011funu teyit edin.<\/td><\/tr>\n<tr><td>Boyutlar ve kablolama<\/td><td>Bu sayfada yay\u0131nlanmam\u0131\u015ft\u0131r<\/td><td>Tasar\u0131m a\u015famas\u0131na ge\u00e7meden \u00f6nce kesin \u00e7izimleri ve belgeleri talep edin.<\/td><\/tr>\n<\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Exact-Model Do\u011frulama \u0130\u015f Ak\u0131\u015f\u0131<\/h2>\n\n\n\n<ol class=\"wp-block-list\"><li>Y\u00fck\u00fc ve \u00e7al\u0131\u015fma s\u0131ras\u0131n\u0131 a\u00e7\u0131klay\u0131n.<\/li><li>Yetkili belgelerden ge\u00e7erli kullan\u0131m kategorisini belirleyin.<\/li><li>G\u00fc\u00e7 devresinin gerilimini, faz d\u00fczenini ve gerekli \u00e7al\u0131\u015fma ak\u0131m\u0131n\u0131 veya motor verilerini belirtin.<\/li><li>Bobin\/kontrol besleme t\u00fcr\u00fcn\u00fc, gerilimini ve frekans\u0131n\u0131 belirtin.<\/li><li>Ana kutup ve yard\u0131mc\u0131 kontak gereksinimlerini belirleyin.<\/li><li>Beklenen \u00e7al\u0131\u015fma frekans\u0131, muhafaza ve \u00e7evresel ko\u015fullar\u0131 belirtin.<\/li><li>A\u015f\u0131r\u0131 y\u00fck, devre koruma, kilitleme ve mar\u015f motoru gereksinimlerini belirleyin.<\/li><li>Tam model ad\u0131n\u0131, sipari\u015f kodunu, teknik \u00f6zellik belgesini, boyutlar\u0131 ve kablolama bilgilerini isteyin.<\/li><\/ol>\n\n\n\n<h2 class=\"wp-block-heading\">Bir AC kontakt\u00f6r\u00fc talebinde yer almas\u0131 gereken bilgiler<\/h2>\n\n\n\n<ul class=\"wp-block-list\"><li>Uygulama ve y\u00fck t\u00fcr\u00fc<\/li><li>\u00c7al\u0131\u015fma s\u0131ras\u0131 ve gerekli kullan\u0131m kategorisi<\/li><li>G\u00fc\u00e7 devresinin gerilimi, faz\u0131 ve frekans\u0131<\/li><li>Belirtilen gerilimde gerekli \u00e7al\u0131\u015fma ak\u0131m\u0131 veya motor g\u00fcc\u00fc<\/li><li>Bobin\/kontrol besleme t\u00fcr\u00fc, gerilim ve frekans<\/li><li>Ana kutup d\u00fczeni<\/li><li>Gerekli yard\u0131mc\u0131 NO\/NC kontaklar\u0131<\/li><li>Saat ba\u015f\u0131na veya \u00e7al\u0131\u015fma d\u00f6ng\u00fcs\u00fc ba\u015f\u0131na beklenen i\u015flem say\u0131s\u0131<\/li><li>Ortam, muhafaza ve montaj ko\u015fullar\u0131<\/li><li>\u0130lgili a\u015f\u0131r\u0131 y\u00fck r\u00f6lesi, mar\u015f motoru, MPCB, kilitleme mekanizmas\u0131 veya aksesuar gereksinimleri<\/li><li>Gerekli teknik veri sayfas\u0131, \u00e7izimler, kablolama \u015femalar\u0131 ve sertifikalar<\/li><li>Miktar ve var\u0131\u015f yeri<\/li><\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Teknik Kaynaklar<\/h2>\n\n\n\n<ul class=\"wp-block-list\"><li><a href=\"https:\/\/www.se.com\/uk\/en\/faqs\/FA142452\/\" target=\"_blank\" rel=\"noopener\">Schneider Electric \u2014 Bir kontakt\u00f6r\u00fcn \u00f6zelliklerini belirlemek i\u00e7in hangi bilgiler gereklidir?<\/a> \u2014 Ana kontaklar, yard\u0131mc\u0131 kontaklar ve bobin gereksinimlerinin ayr\u0131lmas\u0131n\u0131 destekler.<\/li><li><a href=\"https:\/\/productinfo.se.com\/tesysgigainstallationguide\/tesys-giga-series-giga-contactors-and-giga-thermal-overload-relays-installation-guide\/English\/TeSys%E2%84%A2%20Giga%20Series%20Giga%20Contactors%20and%20Giga%20Thermal%20Overload%20Relays%20Installation%20Guide_0000447511.xml\/%24\/PanGu_LoadsCPT_0000507717\" target=\"_blank\" rel=\"noopener\">Schneider Electric TeSys Giga \u2014 Kullan\u0131m Kategorileri<\/a> \u2014 G\u00f6rev de\u011fi\u015ftirme ile g\u00f6reve \u00f6zg\u00fc yeterlilik derecelendirmelerine duyulan ihtiya\u00e7 aras\u0131ndaki ayr\u0131m\u0131 destekler.<\/li><\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">S\u0131k Sorulan Sorular<\/h2>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Sadece motor g\u00fcc\u00fcne g\u00f6re bir AC kontakt\u00f6r\u00fc se\u00e7ebilir miyim?<\/summary><p class=\"wp-block-paragraph\">Hay\u0131r. Motor g\u00fcc\u00fc, belirtilen \u00e7al\u0131\u015fma gerilimi, kullan\u0131m kategorisi ve tam modelle uyumlu olmal\u0131d\u0131r. Bobin beslemesi, kutuplar, yard\u0131mc\u0131 kontaklar, \u00e7al\u0131\u015fma frekans\u0131 ve kurulum ko\u015fullar\u0131 da konfig\u00fcrasyonu etkileyebilir.<\/p><\/details>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>AC-3 ve AC-4 kontakt\u00f6r de\u011ferleri aras\u0131ndaki fark nedir?<\/summary><p class=\"wp-block-paragraph\">They represent different motor-switching duties. AC-3 is associated with normal squirrel-cage motor starting and switching off while running. AC-4 covers more severe operations such as plugging, inching or reversing. Use the exact manufacturer&#8217;s rating for the required duty.<\/p><\/details>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Kontakt\u00f6r bobininin gerilimi, motorun gerilimi ile ayn\u0131 m\u0131d\u0131r?<\/summary><p class=\"wp-block-paragraph\">\u0130lle de \u00f6yle de\u011fil. Bobin kontrol devresine aittir ve anahtarlamal\u0131 g\u00fc\u00e7 devresinden farkl\u0131 bir gerilime ihtiya\u00e7 duyabilir. Her ikisini de ayr\u0131 ayr\u0131 belirtin.<\/p><\/details>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Her ZS3TF modelinde 2NO + 2NC yard\u0131mc\u0131 kontak bulunur mu?<\/summary><p class=\"wp-block-paragraph\">Hay\u0131r. Mevcut kan\u0131tlar, 2NO + 2NC ailesine ait bir a\u00e7\u0131klama sunmaktad\u0131r, ancak bu d\u00fczeni her modele uydurmamaktad\u0131r. Kesin yap\u0131land\u0131rmay\u0131 teyit edin.<\/p><\/details>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Bir AC kontakt\u00f6r\u00fc, motora a\u015f\u0131r\u0131 y\u00fck veya k\u0131sa devre korumas\u0131 sa\u011flar m\u0131?<\/summary><p class=\"wp-block-paragraph\">Kontakt\u00f6r, bir anahtarlama cihaz\u0131d\u0131r. A\u015f\u0131r\u0131 y\u00fck ve k\u0131sa devre korumas\u0131 i\u00e7in ayr\u0131, do\u011fru \u015fekilde se\u00e7ilmi\u015f ve belgelenmi\u015f cihazlar veya tertibatlar gereklidir.<\/p><\/details>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Sipari\u015f vermeden \u00f6nce ZS3TF ile ilgili hangi bilgiler do\u011frulanmal\u0131d\u0131r?<\/summary><p class=\"wp-block-paragraph\">Tam model ve sipari\u015f kodunu, g\u00f6revi, \u00e7al\u0131\u015fma gerilimini ve ak\u0131m\u0131n\u0131, bobin beslemesini, kutuplar\u0131, yard\u0131mc\u0131 kontaklar\u0131, anahtarlama gereksinimlerini, boyutlar\u0131, kablolamay\u0131, aksesuarlar\u0131 ve gerekli belgeleri teyit edin.<\/p><\/details>\n\n\n\n<div class=\"wp-block-group has-base-color has-contrast-background-color has-text-color has-background is-layout-constrained wp-block-group-is-layout-constrained\">\n<h2 class=\"wp-block-heading\">Projeniz i\u00e7in bir AC kontakt\u00f6r yap\u0131land\u0131rmas\u0131n\u0131 onaylay\u0131n<\/h2>\n\n\n<p class=\"wp-block-paragraph\">RITOKS\u2019a, kesin model incelemesi i\u00e7in y\u00fck g\u00f6revini, g\u00fc\u00e7 devresi gereksinimlerini, bobin beslemesini, kontak d\u00fczenini, \u00e7al\u0131\u015fma frekans\u0131n\u0131, dok\u00fcmantasyon ihtiya\u00e7lar\u0131n\u0131 ve miktar\u0131 g\u00f6nderin.<\/p>\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/ritoks.com\/tr\/contact-us\/\">Fiyat teklifi almak i\u00e7in RITOKS ile ileti\u015fime ge\u00e7in<\/a><\/div>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Learn how to specify an industrial AC contactor by load duty, operating current and voltage, coil supply, poles, auxiliary contacts and exact model documentation.<\/p>","protected":false},"author":1,"featured_media":898,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"no-sidebar","site-content-layout":"page-builder","ast-site-content-layout":"full-width-container","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"disabled","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"disabled","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ritoks_resource_detail_renderer":"viox","ritoks_resource_product_cat_term_id":0,"footnotes":""},"categories":[65],"tags":[],"class_list":["post-1071","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-motor-control-protection"],"acf":[],"spectra_blocks_featured_image_url":{"thumbnail":{"url":"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/zs3tf-series-ac-contactor-draft-preview-150x150.webp","width":150,"height":150},"medium":{"url":"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/zs3tf-series-ac-contactor-draft-preview-300x300.webp","width":300,"height":300},"medium_large":{"url":"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/zs3tf-series-ac-contactor-draft-preview-768x768.webp","width":768,"height":768},"large":{"url":"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/zs3tf-series-ac-contactor-draft-preview-1024x1024.webp","width":1024,"height":1024},"full":{"url":"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/zs3tf-series-ac-contactor-draft-preview.webp","width":1200,"height":1200}},"spectra_blocks_author_info":{"display_name":"RITOKS","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/6d7d0fc73468198f994ab13ef6eb6558c53b6ed1ad86364d5165efe8bdf8eb4a?s=96&d=mm&r=g","author_link":"https:\/\/ritoks.com\/tr\/author\/dazzlingwqbgmail-com\/","description":""},"_links":{"self":[{"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/posts\/1071","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/comments?post=1071"}],"version-history":[{"count":4,"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/posts\/1071\/revisions"}],"predecessor-version":[{"id":2169,"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/posts\/1071\/revisions\/2169"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/media\/898"}],"wp:attachment":[{"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/media?parent=1071"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/categories?post=1071"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/tags?post=1071"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}