{"id":1148,"date":"2026-09-20T00:16:24","date_gmt":"2026-09-20T00:16:24","guid":{"rendered":"https:\/\/ritoks.com\/?p=1148"},"modified":"2026-10-04T06:58:18","modified_gmt":"2026-10-04T06:58:18","slug":"mpcb-vs-overload-relay-vs-mcb","status":"publish","type":"post","link":"https:\/\/ritoks.com\/tr\/mpcb-vs-overload-relay-vs-mcb\/","title":{"rendered":"MPCB, Termal A\u015f\u0131r\u0131 Y\u00fck R\u00f6lesi ve MCB: \u0130\u015flevleri ve Se\u00e7im Kriterleri"},"content":{"rendered":"<p class=\"wp-block-paragraph\">Bir MCB, bir motor koruma devre kesicisi ve bir termal a\u015f\u0131r\u0131 y\u00fck r\u00f6lesi, ayn\u0131 motor kontrol\u00fc konusunun ele al\u0131n\u0131\u015f\u0131nda bahsedilebilir; ancak bu isimler, i\u015flevlerinin ayn\u0131 oldu\u011funu veya se\u00e7im kurallar\u0131n\u0131n birbirinin yerine kullan\u0131labilece\u011fini g\u00f6stermez. Gerekli cihaz seti, motora, uygulamaya, kontrol mimarisine ve \u00fcreticinin sa\u011flad\u0131\u011f\u0131 kesin koordinasyon belgelerine ba\u011fl\u0131d\u0131r.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Bu kar\u015f\u0131la\u015ft\u0131rma, kaynak se\u00e7imi i\u00e7in i\u015flevsel s\u0131n\u0131rlar\u0131 a\u00e7\u0131klamaktad\u0131r. Bu, bir kablo \u015femas\u0131, koordinasyon tablosu, devre kesme ayar talimat\u0131 veya belirli bir bile\u015fen kombinasyonunun onay\u0131 de\u011fildir.<\/p>\n\n\n\n<figure data-spectra-id=\"spectra-86262f80-a774-424b-a253-5ede1856ac4f\" class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" height=\"810\" width=\"1440\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/rc006-mcb-mpcb-overload-relay-product-form-comparison-r2.webp\" alt=\"Bir AC MCB, bir motor koruma devre kesicisi ve bir termal a\u015f\u0131r\u0131 y\u00fck r\u00f6lesini ayr\u0131 cihazlar olarak g\u00f6steren ger\u00e7ek \u00fcr\u00fcn \u015fekli kar\u015f\u0131la\u015ft\u0131rmas\u0131\" class=\"wp-image-1158\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/rc006-mcb-mpcb-overload-relay-product-form-comparison-r2.webp 1440w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/rc006-mcb-mpcb-overload-relay-product-form-comparison-r2-600x338.webp 600w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/rc006-mcb-mpcb-overload-relay-product-form-comparison-r2-300x169.webp 300w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/rc006-mcb-mpcb-overload-relay-product-form-comparison-r2-1024x576.webp 1024w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/rc006-mcb-mpcb-overload-relay-product-form-comparison-r2-768x432.webp 768w\" sizes=\"auto, (max-width: 1440px) 100vw, 1440px\" \/><figcaption class=\"wp-element-caption\">Rol kar\u015f\u0131la\u015ft\u0131rmas\u0131 i\u00e7in \u00fc\u00e7 ayr\u0131 \u00fcr\u00fcn t\u00fcr\u00fc. Bu d\u00fczen, do\u011frulanm\u0131\u015f bir kombinasyon, kurulum, kablolama veya koordinasyon \u015femas\u0131n\u0131 temsil etmemektedir.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">\u0130\u015flevsel Rollere Genel Bir Bak\u0131\u015f<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Cihaz<\/th><th>Kan\u0131tlara dayal\u0131 rol\u00fc<\/th><th>Hala kesin bir do\u011frulama gerektiren hususlar<\/th><\/tr><\/thead><tbody><tr><td>MCB<\/td><td>A\u015f\u0131r\u0131 y\u00fck ve k\u0131sa devreye kar\u015f\u0131 genel devre a\u015f\u0131r\u0131 ak\u0131m korumas\u0131.<\/td><td>Motor uygunlu\u011fu, \u00e7al\u0131\u015fma e\u011frisi, frenleme kapasitesi, gerilim ve kurulum kurallar\u0131.<\/td><\/tr>\n<tr><td>MPCB<\/td><td>Belgelendirilmi\u015f bir motor devre kesicisi, ayarlanabilir motor a\u015f\u0131r\u0131 y\u00fck korumas\u0131 ile manyetik k\u0131sa devre korumas\u0131n\u0131 bir arada bar\u0131nd\u0131rabilir.<\/td><td>Motor verileri, ayar aral\u0131\u011f\u0131, gerilim, frenleme tablosu, aksesuarlar ve koordinasyon.<\/td><\/tr>\n<tr><td>Termal a\u015f\u0131r\u0131 y\u00fck r\u00f6lesi<\/td><td>Motor a\u015f\u0131r\u0131 y\u00fck korumas\u0131; belirtildi\u011fi durumlarda faz kayb\u0131 hassasiyeti.<\/td><td>A\u00e7ma s\u0131n\u0131f\u0131, s\u0131f\u0131rlama davran\u0131\u015f\u0131, kontakt\u00f6r e\u015flemesi, montaj ve yukar\u0131 ak\u0131m k\u0131sa devre korumas\u0131.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure data-spectra-id=\"spectra-b56fdd9f-38d7-42cc-92b9-7f7563b4fcff\" class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" height=\"1500\" width=\"1200\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/rc006-motor-protection-role-comparison.png\" alt=\"Motor kontrol korumas\u0131nda MCB, MPCB ve termal a\u015f\u0131r\u0131 y\u00fck r\u00f6lesinin i\u015flevlerinin kar\u015f\u0131la\u015ft\u0131r\u0131lmas\u0131\" class=\"wp-image-1143\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/rc006-motor-protection-role-comparison.png 1200w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/rc006-motor-protection-role-comparison-600x750.png 600w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/rc006-motor-protection-role-comparison-240x300.png 240w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/rc006-motor-protection-role-comparison-819x1024.png 819w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/rc006-motor-protection-role-comparison-768x960.png 768w\" sizes=\"auto, (max-width: 1200px) 100vw, 1200px\" \/><figcaption class=\"wp-element-caption\">Bu \u00fc\u00e7 cihaz t\u00fcr\u00fc, kan\u0131tlama a\u00e7\u0131s\u0131ndan farkl\u0131 roller \u00fcstlenmektedir. Bu kar\u015f\u0131la\u015ft\u0131rma, kablolama k\u0131lavuzu niteli\u011finde de\u011fildir ve herhangi bir bile\u015fen kombinasyonunun onayland\u0131\u011f\u0131 anlam\u0131na da gelmez.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">1. Bir MCB\u2019nin Sa\u011flad\u0131\u011f\u0131 Faydalar<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">ABB, minyat\u00fcr devre kesiciyi, elektrik \u015febekelerindeki a\u015f\u0131r\u0131 y\u00fck ve k\u0131sa devre durumlar\u0131na kar\u015f\u0131 yeniden ayarlanabilir bir a\u015f\u0131r\u0131 ak\u0131m koruma cihaz\u0131 olarak tan\u0131mlamaktad\u0131r. Bu genel tan\u0131m, herhangi bir MCB\u2019nin belirli bir motor dal devresine uygun oldu\u011funu g\u00f6stermez.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Motor uygulamalar\u0131 i\u00e7in, kesicinin tam gerilimini, kutuplar\u0131n\u0131, a\u00e7\u0131lma karakteristi\u011fini, kesme kapasitesini ve ge\u00e7erli motor devresi kurallar\u0131n\u0131 do\u011frulay\u0131n. Mevcut RITOKS MCB k\u0131lavuzlar\u0131 kendi e\u011frilerini ve teklif talebi (RFQ) ama\u00e7lar\u0131n\u0131 korumaktad\u0131r; bu makale s\u00f6z konusu se\u00e7im kurallar\u0131n\u0131 tekrarlamamaktad\u0131r.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">2. MPCB\u2019nin Katk\u0131s\u0131 Nedir?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A <a href=\"https:\/\/ritoks.com\/tr\/product-category\/ac-power-protection\/motor-protection-circuit-breakers\/\">motor koruma devre kesici<\/a> motor devresi gereksinimlerine g\u00f6re se\u00e7ilir. Kesin i\u015flevler, yaln\u0131zca \u00fcr\u00fcn grubu ad\u0131ndan de\u011fil, \u00fcr\u00fcn kayd\u0131ndan belirlenir.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Yay\u0131mlanan <a href=\"https:\/\/ritoks.com\/tr\/products\/gymp7-three-phase-motor-protection-circuit-breakers\/\">GYMP7 motor koruma devre kesici serisi<\/a> \u00dc\u00e7 fazl\u0131 mimariyi, ayarlanabilir termal a\u015f\u0131r\u0131 y\u00fck korumas\u0131n\u0131 ve manyetik k\u0131sa devre korumas\u0131n\u0131 belirtir. 0,1 A ile 80 A aras\u0131ndaki aral\u0131kta modele \u00f6zg\u00fc kesin ayar aral\u0131klar\u0131n\u0131 kapsar. Icu ve Ics de\u011ferleri, se\u00e7ilen g\u00f6vde tipine, ak\u0131m aral\u0131\u011f\u0131na ve gerilim tablosuna uygun olmal\u0131d\u0131r.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">GYMP7 derecelendirmelerini her MPCB i\u00e7in genelle\u015ftirmeyin. Se\u00e7ilen cihaz i\u00e7in kesin motor verileri, ayar aral\u0131\u011f\u0131, \u00e7al\u0131\u015fma gerilimi, beklenen ar\u0131za seviyesi ve gerekli aksesuarlar g\u00f6zden ge\u00e7irilmelidir.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">3. Termal A\u015f\u0131r\u0131 Y\u00fck R\u00f6lesinin \u0130\u015flevi<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u00dcreticinin resmi belgelerinde \u015funlar a\u00e7\u0131klanmaktad\u0131r: <a href=\"https:\/\/ritoks.com\/tr\/product-category\/industrial-power-switching\/thermal-overload-relays\/\">termal a\u015f\u0131r\u0131 y\u00fck r\u00f6leleri<\/a> a\u015f\u0131r\u0131 y\u00fck ve faz kesintisi durumlar\u0131na kar\u015f\u0131 motor koruma cihazlar\u0131 olarak. Ayr\u0131 bir a\u015f\u0131r\u0131 y\u00fck r\u00f6lesi, tek ba\u015f\u0131na motor dal devresinde k\u0131sa devre korumas\u0131 sa\u011flamaz.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Yay\u0131mlanan <a href=\"https:\/\/ritoks.com\/tr\/products\/zs3ru-thermal-overload-relays-0-11a-100a\/\">ZS3RU termal a\u015f\u0131r\u0131 y\u00fck r\u00f6lesi serisi<\/a> Belgede, 0,11 A ile 100 A aras\u0131ndaki modele \u00f6zg\u00fc ayar aral\u0131klar\u0131, \u00fc\u00e7 fazl\u0131 asenkron motor uygulamalar\u0131, a\u015f\u0131r\u0131 y\u00fck ve faz kayb\u0131 korumas\u0131, s\u0131cakl\u0131k telafisi ve devre kesme g\u00f6stergesi belirtilmi\u015ftir. Mevcut bilgilere g\u00f6re, devre kesme s\u0131n\u0131f\u0131, s\u0131f\u0131rlama modu, yard\u0131mc\u0131 kontaklar veya kesin kontakt\u00f6r e\u015flemesi a\u00e7\u0131klanmam\u0131\u015ft\u0131r.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">4. Kontrol ve Koruma \u0130\u015flevlerini Ayr\u0131 Tutun<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Bir kontakt\u00f6r, kontroll\u00fc anahtarlama i\u015flevi sa\u011flar. Bir a\u015f\u0131r\u0131 y\u00fck r\u00f6lesi, belgelenmi\u015f a\u015f\u0131r\u0131 y\u00fck i\u015flevini yerine getirir. Bir k\u0131sa devre koruma cihaz\u0131, belgelenmi\u015f ar\u0131za ak\u0131m\u0131 i\u015flevini yerine getirir. Baz\u0131 MPCB\u2019ler birden fazla motor koruma i\u015flevini bir araya getirir, ancak bu durum her <a href=\"https:\/\/ritoks.com\/tr\/product-category\/industrial-power-switching\/motor-starters\/\">motor devre ba\u015flat\u0131c\u0131<\/a> mimari a\u00e7\u0131dan ayn\u0131.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u015eu <a href=\"https:\/\/ritoks.com\/tr\/ac-contactor-selection-guide\/\">AC Kontakt\u00f6r Se\u00e7im K\u0131lavuzu<\/a> ayr\u0131 g\u00fc\u00e7 devresi, bobin ve yard\u0131mc\u0131 kontak giri\u015flerini a\u00e7\u0131klamaktad\u0131r. Yay\u0131nlanm\u0131\u015f RITOKS \u00f6rnekleri aras\u0131nda \u015funlar da yer almaktad\u0131r: <a href=\"https:\/\/ritoks.com\/tr\/products\/zsle1-d-enclosed-magnetic-motor-starter\/\">ZSLE1-D kapal\u0131 tip manyetik motor devreye al\u0131c\u0131<\/a>. Bu ba\u011flant\u0131lar, ilgili \u00fcr\u00fcn ailelerini g\u00f6sterir; uyumluluklar\u0131 teyit edilmemi\u015ftir.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">5. Koordinasyon, \u00fcreticiden kesin kan\u0131t gerektirir<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Schneider Electric\u2019in motor koruma k\u0131lavuzu, devre kesme, k\u0131sa devre korumas\u0131, kontrol ve a\u015f\u0131r\u0131 y\u00fck korumas\u0131n\u0131 birbirinden ay\u0131r\u0131r. Birden fazla cihaz kullan\u0131ld\u0131\u011f\u0131nda, bunlar\u0131n bir arada \u00e7al\u0131\u015fmas\u0131 bir kombinasyon olarak do\u011frulanmal\u0131d\u0131r. Uygun bir ak\u0131m aral\u0131\u011f\u0131 veya marka ad\u0131 tek ba\u015f\u0131na yeterli de\u011fildir.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Se\u00e7ilen kesici, kontakt\u00f6r ve r\u00f6le seti i\u00e7in \u00fcreticinin tam koordinasyon tablosu olmadan, Tip 1 veya Tip 2 koordinasyon talebini, kesme kapasitesi kombinasyonunu, devre kesme ayar\u0131n\u0131 veya bile\u015fen de\u011fi\u015ftirme bilgisini yay\u0131nlamay\u0131n\u0131z.<\/p>\n\n\n\n<figure data-spectra-id=\"spectra-f126588b-3df0-41d9-89ce-5d870122f96b\" class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" height=\"1500\" width=\"1200\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/rc006-motor-coordination-evidence-checklist.png\" alt=\"Cihaz verileri ve kesin koordinat tablolar\u0131 i\u00e7in motor kontrol\u00fc teklif talebi kan\u0131t kontrol listesi\" class=\"wp-image-1144\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/rc006-motor-coordination-evidence-checklist.png 1200w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/rc006-motor-coordination-evidence-checklist-600x750.png 600w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/rc006-motor-coordination-evidence-checklist-240x300.png 240w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/rc006-motor-coordination-evidence-checklist-819x1024.png 819w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/rc006-motor-coordination-evidence-checklist-768x960.png 768w\" sizes=\"auto, (max-width: 1200px) 100vw, 1200px\" \/><figcaption class=\"wp-element-caption\">Koordineli bir kombinasyon talebinde bulunmadan \u00f6nce motor, i\u015flev ve cihaz giri\u015flerini toplay\u0131n. Koordinasyon tablosunun olmamas\u0131, uyumluluk iddias\u0131n\u0131n da olmad\u0131\u011f\u0131 anlam\u0131na gelir.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Yay\u0131nlanm\u0131\u015f RITOKS \u00dcr\u00fcn Ailesi \u00d6rnekleri<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Aile<\/th><th>Do\u011frulanm\u0131\u015f genel kapsam<\/th><th>S\u0131n\u0131r<\/th><\/tr><\/thead><tbody><tr><td>GYMP7 MPCB<\/td><td>\u00dc\u00e7 fazl\u0131; model gruplar\u0131 genelinde 0,1\u201380 A aral\u0131\u011f\u0131nda ayarlanabilir; termal a\u015f\u0131r\u0131 y\u00fck ve manyetik k\u0131sa devre korumas\u0131.<\/td><td>Tam model ve gerilim tablolar\u0131n\u0131 kullan\u0131n; varsay\u0131msal aksesuar veya mar\u015f motoru e\u015fle\u015fmelerinden ka\u00e7\u0131n\u0131n.<\/td><\/tr>\n<tr><td>ZS3RU a\u015f\u0131r\u0131 y\u00fck r\u00f6lesi<\/td><td>Model serileri genelinde 0,11\u2013100 A; \u00fc\u00e7 fazl\u0131 asenkron motorlar i\u00e7in a\u015f\u0131r\u0131 y\u00fck ve faz kayb\u0131 korumas\u0131.<\/td><td>Hareket s\u0131n\u0131f\u0131, s\u0131f\u0131rlama modu ve kesin kontakt\u00f6r e\u015flemesi hen\u00fcz do\u011frulanmam\u0131\u015ft\u0131r.<\/td><\/tr>\n<tr><td>ZS3TF kontakt\u00f6r\u00fc<\/td><td>Modele \u00f6zg\u00fc g\u00f6rev derecesine g\u00f6re kontroll\u00fc anahtarlama.<\/td><td>Bir kontakt\u00f6r, a\u015f\u0131r\u0131 y\u00fck veya k\u0131sa devre korumas\u0131 de\u011fildir.<\/td><\/tr>\n<tr><td>ZSLE1-D mar\u015f motoru<\/td><td>Ekteki manyetik motor devre kesici serisi yay\u0131nland\u0131.<\/td><td>Kesin i\u00e7 mimari ve koordinasyonun teyit edilmesi gerekmektedir.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Motor Koruma Teklif Talebinde Yer Almas\u0131 Gereken Bilgiler<\/h2>\n\n\n\n<ul class=\"wp-block-list\"><li>Motorun nominal ak\u0131m\u0131, gerilimi, faz\u0131 ve frekans\u0131<\/li><li>Motor g\u00fcc\u00fc ve \u00e7al\u0131\u015ft\u0131rma y\u00f6ntemi<\/li><li>Y\u00fck y\u00fck\u00fc, \u00e7al\u0131\u015ft\u0131rma s\u0131kl\u0131\u011f\u0131 ve \u00e7al\u0131\u015fma ko\u015fullar\u0131<\/li><li>Gerekli a\u015f\u0131r\u0131 y\u00fck, faz kayb\u0131 ve k\u0131sa devre i\u015flevleri<\/li><li>Gerekli izolasyon ve kontrol i\u015flevleri<\/li><li>Olas\u0131 k\u0131sa devre bilgileri<\/li><li>MPCB veya a\u015f\u0131r\u0131 y\u00fck r\u00f6lesi ayar aral\u0131\u011f\u0131 aday\u0131<\/li><li>Kontakt\u00f6r veya mar\u015f motoru gereksinimleri<\/li><li>Gerekli koordinat seviyesi ve kesin \u00fcretici tablosu<\/li><li>Montaj, muhafaza ve aksesuar gereksinimleri<\/li><li>Miktar, var\u0131\u015f yeri ve gerekli belgeler<\/li><\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Teknik Kaynaklar<\/h2>\n\n\n\n<ul class=\"wp-block-list\"><li><a href=\"https:\/\/library.e.abb.com\/public\/580e60db881d42ce8320ee8fa38a5ca0\/102468_1SXU400208C0201_1116.pdf\" target=\"_blank\" rel=\"noopener\">ABB \u2014 Minyat\u00fcr Devre Kesici Uygulama K\u0131lavuzu<\/a> \u2014 MCB\u2019lerin genel a\u015f\u0131r\u0131 y\u00fck ve k\u0131sa devre koruma i\u015flevini destekler; kesin de\u011ferler \u00fcr\u00fcne g\u00f6re de\u011fi\u015fiklik g\u00f6sterir.<\/li><li><a href=\"https:\/\/library.e.abb.com\/public\/bb5eba9f124140bfb381a571281416a2\/1SXU000023C0202_RevA_02%20Motor%20overload%20protection.pdf\" target=\"_blank\" rel=\"noopener\">ABB \u2014 Motor A\u015f\u0131r\u0131 Y\u00fck Korumas\u0131<\/a> \u2014 Termal a\u015f\u0131r\u0131 y\u00fck r\u00f6lelerinin genel a\u015f\u0131r\u0131 y\u00fck ve faz kesintisi koruma i\u015flevini destekler.<\/li><li><a href=\"https:\/\/www.se.com\/in\/en\/download\/document\/LVED250601EN\/\" target=\"_blank\" rel=\"noopener\">Schneider Electric \u2014 Motor Koruma Koordinasyon K\u0131lavuzu<\/a> \u2014 Kesme, k\u0131sa devre korumas\u0131, kontrol ve a\u015f\u0131r\u0131 y\u00fck i\u015flevlerinin birbirinden ayr\u0131 tutulmas\u0131n\u0131 ve bu i\u015flevlerin kombinasyonlar\u0131n\u0131n koordinasyon belgeleri temelinde do\u011frulanmas\u0131n\u0131 destekler.<\/li><\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">S\u0131k Sorulan Sorular<\/h2>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>MPCB ile MCB ayn\u0131 \u015fey midir?<\/summary><p class=\"wp-block-paragraph\">Hay\u0131r. Cihazlar\u0131n a\u015f\u0131r\u0131 ak\u0131m i\u015flevleri birbiriyle \u00f6rt\u00fc\u015febilir, ancak motor devresi gereksinimleri belgelerde belirtildi\u011fi \u015fekilde bir MPCB se\u00e7ilir. Kesin i\u015flevler ve teknik \u00f6zellikler, se\u00e7ilen \u00fcr\u00fcn\u00fcn belgelerinden al\u0131nmal\u0131d\u0131r.<\/p><\/details>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Termal a\u015f\u0131r\u0131 y\u00fck r\u00f6lesi k\u0131sa devrelere kar\u015f\u0131 koruma sa\u011flar m\u0131?<\/summary><p class=\"wp-block-paragraph\">Termal a\u015f\u0131r\u0131 y\u00fck r\u00f6lesini tam bir k\u0131sa devre korumas\u0131 olarak de\u011ferlendirmeyin. Bu r\u00f6lenin a\u015f\u0131r\u0131 y\u00fck i\u015flevi, ilgili k\u0131sa devre koruma cihaz\u0131yla uyumlu olmal\u0131d\u0131r.<\/p><\/details>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>GYMP7\u2019yi herhangi bir kontakt\u00f6r veya a\u015f\u0131r\u0131 y\u00fck r\u00f6lesiyle birle\u015ftirebilir miyim?<\/summary><p class=\"wp-block-paragraph\">Se\u00e7ilen cihazlar i\u00e7in kesin bir \u00fcretici koordinasyonu veya uyumluluk tablosu olmadan herhangi bir uyumluluk iddias\u0131nda bulunulmamaktad\u0131r.<\/p><\/details>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Bir MCB, yaln\u0131zca motor ak\u0131m\u0131 dikkate al\u0131narak se\u00e7ilebilir mi?<\/summary><p class=\"wp-block-paragraph\">Hay\u0131r. Motor uygulamas\u0131, \u00e7al\u0131\u015ft\u0131rma davran\u0131\u015f\u0131, devre kesme \u00f6zelli\u011fi, gerilim, kesme kapasitesi ve ilgili kurallar da incelenmelidir.<\/p><\/details>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>ZS3RU sipari\u015f etmeden \u00f6nce nelere dikkat edilmelidir?<\/summary><p class=\"wp-block-paragraph\">Kesin ak\u0131m ayar aral\u0131\u011f\u0131n\u0131, devre kesme davran\u0131\u015f\u0131n\u0131, s\u0131f\u0131rlama gereklili\u011fini, montaj y\u00f6ntemini, kontakt\u00f6r ili\u015fkisini, \u00fcst kademedeki korumay\u0131 ve belgeleri teyit edin.<\/p><\/details>\n\n\n\n<div class=\"wp-block-group has-base-color has-contrast-background-color has-text-color has-background is-layout-constrained wp-block-group-is-layout-constrained\">\n<h2 class=\"wp-block-heading\">Bir Motor Koruma Cihaz\u0131 Seti Tan\u0131mlay\u0131n<\/h2>\n\n\n<p class=\"wp-block-paragraph\">RITOKS\u2019a motor verilerini, gerekli koruma ve kontrol i\u015flevlerini, ar\u0131za seviyesi bilgilerini, aday cihaz gruplar\u0131n\u0131, koordinasyon gereksinimini, adedi ve teslimat adresini g\u00f6nderin.<\/p>\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/ritoks.com\/tr\/contact-us\/\">Fiyat teklifi almak i\u00e7in RITOKS ile ileti\u015fime ge\u00e7in<\/a><\/div>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>MPCB\u2019leri, termal a\u015f\u0131r\u0131 y\u00fck r\u00f6lelerini ve MCB\u2019leri, cihazlar\u0131n i\u015flevlerine, motor devresi uygulamalar\u0131na ve kesin do\u011frulama gerektiren koordinasyon verilerine g\u00f6re kar\u015f\u0131la\u015ft\u0131r\u0131n.<\/p>","protected":false},"author":1,"featured_media":1158,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"no-sidebar","site-content-layout":"page-builder","ast-site-content-layout":"full-width-container","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"disabled","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"disabled","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ritoks_resource_detail_renderer":"viox","ritoks_resource_product_cat_term_id":0,"footnotes":""},"categories":[65],"tags":[],"class_list":["post-1148","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-motor-control-protection"],"acf":[],"spectra_blocks_featured_image_url":{"thumbnail":{"url":"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/rc006-mcb-mpcb-overload-relay-product-form-comparison-r2-150x150.webp","width":150,"height":150},"medium":{"url":"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/rc006-mcb-mpcb-overload-relay-product-form-comparison-r2-300x169.webp","width":300,"height":169},"medium_large":{"url":"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/rc006-mcb-mpcb-overload-relay-product-form-comparison-r2-768x432.webp","width":768,"height":432},"large":{"url":"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/rc006-mcb-mpcb-overload-relay-product-form-comparison-r2-1024x576.webp","width":1024,"height":576},"full":{"url":"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/rc006-mcb-mpcb-overload-relay-product-form-comparison-r2.webp","width":1440,"height":810}},"spectra_blocks_author_info":{"display_name":"RITOKS","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/6d7d0fc73468198f994ab13ef6eb6558c53b6ed1ad86364d5165efe8bdf8eb4a?s=96&d=mm&r=g","author_link":"https:\/\/ritoks.com\/tr\/author\/dazzlingwqbgmail-com\/","description":""},"_links":{"self":[{"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/posts\/1148","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/comments?post=1148"}],"version-history":[{"count":5,"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/posts\/1148\/revisions"}],"predecessor-version":[{"id":2170,"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/posts\/1148\/revisions\/2170"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/media\/1158"}],"wp:attachment":[{"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/media?parent=1148"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/categories?post=1148"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/tags?post=1148"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}