{"id":1269,"date":"2026-09-21T15:38:40","date_gmt":"2026-09-21T15:38:40","guid":{"rendered":"https:\/\/ritoks.com\/?p=1269"},"modified":"2026-10-09T01:15:07","modified_gmt":"2026-10-09T01:15:07","slug":"mpcb-selection-guide","status":"publish","type":"post","link":"https:\/\/ritoks.com\/tr\/mpcb-selection-guide\/","title":{"rendered":"MPCB Se\u00e7im K\u0131lavuzu: Motor Ak\u0131m\u0131, Kesme Aral\u0131\u011f\u0131 ve Kesme Kapasitesi"},"content":{"rendered":"<p class=\"wp-block-paragraph\">Bir motor koruma devre kesicisi, bir motor devresi i\u00e7in en yak\u0131n amper de\u011ferini se\u00e7erek de\u011fil, belirli kriterlere g\u00f6re se\u00e7ilmelidir. Al\u0131c\u0131, motoru, besleme kayna\u011f\u0131n\u0131, \u00e7al\u0131\u015ft\u0131rma davran\u0131\u015f\u0131n\u0131, olas\u0131 ar\u0131za ak\u0131m\u0131n\u0131 ve cihazdan beklenen kesin i\u015flevleri tan\u0131mlamal\u0131d\u0131r. \u00d6nerilen MPCB daha sonra \u00fcreticinin kendi tablolar\u0131nda kontrol edilmelidir.<\/p>\n\n<p class=\"wp-block-paragraph\">Bu makale, MPCB se\u00e7imi konusunda bilgiler i\u00e7ermektedir. Yay\u0131nlanm\u0131\u015f olan MPCB\u2019ler, termal a\u015f\u0131r\u0131 y\u00fck r\u00f6leleri ve MCB\u2019lerin kar\u015f\u0131la\u015ft\u0131rma tablosunun yerini almamaktad\u0131r ve GYMP7 i\u00e7in koordineli bir mar\u015f motoru kombinasyonu \u00f6nermemektedir.<\/p>\n\n\n<figure data-spectra-id=\"spectra-ae740216-b197-4269-bc65-eaa7e69d9847\" class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-037-HERO-01-r2.webp\" alt=\"MPCB se\u00e7imi i\u00e7in ak\u0131m, devre kesme aral\u0131\u011f\u0131 ve ar\u0131za y\u00fck\u00fc ile ilgili a\u00e7\u0131klay\u0131c\u0131 g\u00f6rsel\" class=\"wp-image-1270\" width=\"1600\" height=\"900\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-037-HERO-01-r2.webp 1600w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-037-HERO-01-r2-600x338.webp 600w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-037-HERO-01-r2-300x169.webp 300w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-037-HERO-01-r2-1024x576.webp 1024w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-037-HERO-01-r2-768x432.webp 768w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-037-HERO-01-r2-1536x864.webp 1536w\" sizes=\"auto, (max-width: 1600px) 100vw, 1600px\" \/><\/figure>\n\n\n<h2 class=\"wp-block-heading\">Sat\u0131n Alma Karar\u0131: \u00d6zet<\/h2>\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Karar girdisi<\/th><th>Al\u0131c\u0131 bunu teyit etmelidir<\/th><th>Gerekli kan\u0131tlar<\/th><\/tr><\/thead><tbody><tr><td>Motor kay\u0131tlar\u0131<\/td><td>Anma gerilimi, tam y\u00fck ak\u0131m\u0131, faz ve \u00e7al\u0131\u015ft\u0131rma y\u00f6ntemi<\/td><td>Kesin ayar aral\u0131\u011f\u0131 ve motor y\u00fck verileri<\/td><\/tr><tr><td>Ar\u0131za g\u00f6rev s\u00fcresi<\/td><td>Cihaz\u0131n bulundu\u011fu yerdeki tahmini k\u0131sa devre ak\u0131m\u0131<\/td><td>Ayn\u0131 gerilimde kesme kapasitesi sorunu<\/td><\/tr><tr><td>Seyahat al\u0131\u015fkanl\u0131klar\u0131<\/td><td>Gerekli a\u015f\u0131r\u0131 y\u00fck ve manyetik tepki<\/td><td>Kesin yolculuk bilgileri ve toleranslar<\/td><\/tr><tr><td>Kontrol kapsam\u0131<\/td><td>Manuel \u00e7al\u0131\u015ft\u0131rma, izolasyon ve yard\u0131mc\u0131 sistem gereksinimleri<\/td><td>Belgelenmi\u015f i\u015flevler ve desteklenen aksesuarlar<\/td><\/tr><tr><td>Koordinasyon<\/td><td>Kontakt\u00f6r, yukar\u0131 ve a\u015fa\u011f\u0131 ak\u0131\u015ftaki cihaz kimlikleri<\/td><td>Bir talep yap\u0131ld\u0131\u011f\u0131nda ge\u00e7erli olan kesin \u00fcretici kombinasyon tablosu<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n<figure data-spectra-id=\"spectra-71a1ca57-664e-49a0-99b9-3ae911368191\" class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-037-BODY-01-r2.webp\" alt=\"Motor ak\u0131m\u0131, devre kesme aral\u0131\u011f\u0131, ar\u0131za g\u00f6rev s\u00fcresi aras\u0131ndaki MPCB se\u00e7im ili\u015fkisi ve kesin model kan\u0131tlar\u0131\" class=\"wp-image-1271\" width=\"1400\" height=\"1050\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-037-BODY-01-r2.webp 1400w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-037-BODY-01-r2-600x450.webp 600w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-037-BODY-01-r2-300x225.webp 300w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-037-BODY-01-r2-1024x768.webp 1024w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-037-BODY-01-r2-768x576.webp 768w\" sizes=\"auto, (max-width: 1400px) 100vw, 1400px\" \/><figcaption class=\"wp-element-caption\">Motor ak\u0131m\u0131, devre kesme aral\u0131\u011f\u0131 ve ar\u0131za y\u00fck\u00fc, hepsi de kesin model kan\u0131tlama a\u015famas\u0131n\u0131 ge\u00e7melidir.<\/figcaption><\/figure>\n\n\n<h2 class=\"wp-block-heading\">Motor ve Devreden Ba\u015flay\u0131n<\/h2>\n\n<p class=\"wp-block-paragraph\">Motorun tip plakas\u0131ndaki bilgileri, besleme gerilimi ve frekans\u0131, tam y\u00fck ak\u0131m\u0131, faz d\u00fczeni ve \u00e7al\u0131\u015ft\u0131rma y\u00f6ntemini kaydedin. Beklenen \u00e7al\u0131\u015ft\u0131rma frekans\u0131n\u0131, h\u0131zlanma ko\u015fullar\u0131n\u0131 ve uzun s\u00fcreli ak\u0131m olu\u015fumuna neden olabilecek her t\u00fcrl\u00fc \u00e7al\u0131\u015fma durumunu da ekleyin. Bu veriler, bir ayar aral\u0131\u011f\u0131n\u0131n neden yaln\u0131zca motor g\u00fcc\u00fcne g\u00f6re se\u00e7ilemeyece\u011fini a\u00e7\u0131klamaktad\u0131r.<\/p>\n\n<p class=\"wp-block-paragraph\">\u00d6ng\u00f6r\u00fclen k\u0131sa devre ak\u0131m\u0131n\u0131, normal motor ak\u0131m\u0131ndan ayr\u0131 olarak, MPCB\u2019nin yerle\u015ftirilmesi planlanan konumda kaydedin. Kesicinin, proje geriliminde kesme performans\u0131 belgelenmi\u015f olmal\u0131d\u0131r. Ar\u0131za seviyesi bilinmiyorsa, manyetik a\u00e7ma ayar\u0131n\u0131 bir alternatif olarak kabul etmek yerine, se\u00e7imi durdurun ve hesaplaman\u0131n yap\u0131lmas\u0131n\u0131 talep edin.<\/p>\n\n<h2 class=\"wp-block-heading\">Ayarlama Band\u0131n\u0131 Do\u011fru \u015eekilde Okuyun<\/h2>\n\n<p class=\"wp-block-paragraph\">The motor current should fall within the exact model adjustment range, but range inclusion is only the first gate. Ask how the manufacturer instructs the setting to be established and which ambient or enclosure conditions apply. Do not transfer a setting rule from another series. For the separate checks on overload curves, magnetic response and reference conditions, use the <a href=\"https:\/\/ritoks.com\/tr\/mpcb-trip-characteristics\/\">MPCB trip characteristics guide<\/a>.<\/p>\n\n<p class=\"wp-block-paragraph\">GYMP7, iki \u00e7er\u00e7eve grubu boyunca \u00e7ok say\u0131da belgelenmi\u015f ak\u0131m band\u0131 olarak yay\u0131nlanmaktad\u0131r. Al\u0131c\u0131, \u00f6nerilen sipari\u015f kodunu ve band\u0131 belirlemeli, ard\u0131ndan ilgili gerilim ve kesme verilerini teyit etmelidir. Aile maksimum de\u011feri, her gerilimdeki her band\u0131 tan\u0131mlamaz.<\/p>\n\n<h2 class=\"wp-block-heading\">Ayr\u0131 Koruma \u0130\u015flevleri<\/h2>\n\n<p class=\"wp-block-paragraph\">Bir MPCB, s\u00f6z konusu cihaz i\u00e7in bu i\u015flevlerin a\u00e7\u0131k\u00e7a belirtilmi\u015f olmas\u0131 durumunda, a\u015f\u0131r\u0131 y\u00fck ve k\u0131sa devre koruma i\u015flevlerini bir araya getirebilir. Ancak bu, her t\u00fcrl\u00fc motor kontrol gereklili\u011finin kapsand\u0131\u011f\u0131 anlam\u0131na gelmez. Kontrol bobinleri, uzaktan kumanda, kontakt\u00f6r devreye alma, d\u00fc\u015f\u00fck gerilim davran\u0131\u015f\u0131 ve proses kilitlemeleri, ilgili konfig\u00fcrasyonda aksi belirtilmedik\u00e7e ayr\u0131 kal\u0131r.<\/p>\n\n<p class=\"wp-block-paragraph\">Bir tedarik\u00e7i manuel motor \u00e7al\u0131\u015ft\u0131r\u0131c\u0131dan bahsetti\u011finde, bu terimin sadece kesiciyi mi yoksa belgelenmi\u015f bir kombinasyonu mu ifade etti\u011fini sorun. ABB kataloglar\u0131nda manuel motor \u00e7al\u0131\u015ft\u0131r\u0131c\u0131lar, kontakt\u00f6rler ve a\u015f\u0131r\u0131 y\u00fck bile\u015fenleri ayr\u0131 kay\u0131tlar olarak d\u00fczenlenir ve belirli kombinasyonlar i\u00e7in uyumluluk verileri yay\u0131nlan\u0131r. Buradaki ilke, GYMP7 ile uyumluluk de\u011fil, kan\u0131ta dayal\u0131 bir yakla\u015f\u0131md\u0131r.<\/p>\n\n<h2 class=\"wp-block-heading\">Teklifleri Ayn\u0131 Kriterlere G\u00f6re Kar\u015f\u0131la\u015ft\u0131r\u0131n<\/h2>\n\n<p class=\"wp-block-paragraph\">Her teklifi ayn\u0131 motor, gerilim ve ar\u0131za ak\u0131m\u0131 de\u011ferlerine g\u00f6re standart hale getirin. Ayar aral\u0131\u011f\u0131n\u0131, kesin kesme kapasitesi de\u011ferini, devre kesme bilgilerini, \u00e7al\u0131\u015ft\u0131rma ve izolasyon i\u015flevlerini, montaj \u00f6zelliklerini, terminalleri ve aksesuarlar\u0131 kar\u015f\u0131la\u015ft\u0131r\u0131n. Yaln\u0131zca kesici i\u00e7eren bir teklifin daha d\u00fc\u015f\u00fck fiyat\u0131, montajl\u0131 mar\u015f motoru i\u00e7eren bir teklifle kar\u015f\u0131la\u015ft\u0131r\u0131lamaz.<\/p>\n\n<p class=\"wp-block-paragraph\">En iyi durum senaryolar\u0131n\u0131 birle\u015ftirerek yap\u0131lan kar\u015f\u0131la\u015ft\u0131rmalar\u0131 reddedin. Bir varyanttan en geni\u015f ak\u0131m aral\u0131\u011f\u0131n\u0131, ba\u015fka bir gerilimden en y\u00fcksek kopma de\u011ferini ve \u00fc\u00e7\u00fcnc\u00fc bir varyanttan bir aksesuar g\u00f6rselini almay\u0131n\u0131z. Sipari\u015f edilebilir bir kod ve buna ait destekleyici belgeler, proje kay\u0131tlar\u0131na uygun olmal\u0131d\u0131r.<\/p>\n\n<h2 class=\"wp-block-heading\">Onaydan \u00d6nce Bir Kan\u0131t Dosyas\u0131 Haz\u0131rlay\u0131n<\/h2>\n\n<p class=\"wp-block-paragraph\">\u00d6nerilen MPCB sipari\u015f kodu i\u00e7in bir inceleme tablosu olu\u015fturun. Ba\u015fvuru verilerini sol s\u00fctuna, tedarik\u00e7inin sundu\u011fu kan\u0131tlar\u0131 ise sa\u011f s\u00fctuna yaz\u0131n. En az\u0131ndan motor kay\u0131tlar\u0131, ar\u0131za durumu, devre kesme davran\u0131\u015f\u0131 ile kontrol kapsam\u0131 ve koordinasyonuna ili\u015fkin kay\u0131tlar\u0131 saklay\u0131n. Bu sayede, hangi bilgilerin projeden, hangi beyanlar\u0131n ise \u00fcreticiden geldi\u011fi net bir \u015fekilde ortaya \u00e7\u0131kar.<\/p>\n\n<p class=\"wp-block-paragraph\">Kararda kullan\u0131lan veri sayfalar\u0131n\u0131n, \u00e7izimlerin ve tablolar\u0131n tam kopyalar\u0131n\u0131 ekleyin. Bunlar\u0131n revizyon veya eri\u015fim tarihlerini kaydedin ve belirtilen modele ait sat\u0131r\u0131 vurgulay\u0131n. Bir sat\u0131\u015f e-postas\u0131 kapsam\u0131 netle\u015ftirebilir; ancak karar, bir derecelendirme, ba\u011flant\u0131, devre kesme \u00f6zelli\u011fi, termal s\u0131n\u0131r veya test edilmi\u015f bir kombinasyona ba\u011fl\u0131 oldu\u011funda, teknik belgenin yerini sessizce almamal\u0131d\u0131r.<\/p>\n\n<p class=\"wp-block-paragraph\">Her bir ba\u011flant\u0131l\u0131 de\u011ferin ayn\u0131 sipari\u015f edilebilir konfig\u00fcrasyonu tan\u0131mlad\u0131\u011f\u0131n\u0131 kontrol edin. Benzer model isimleri genellikle ayn\u0131 g\u00f6vdeyi payla\u015f\u0131rken, kontrol beslemesi, ak\u0131m aral\u0131\u011f\u0131, kutuplar, terminaller, aksesuarlar veya \u00e7evresel s\u0131n\u0131rlar a\u00e7\u0131s\u0131ndan farkl\u0131l\u0131k g\u00f6sterebilir. Bir belge birka\u00e7 varyant\u0131 kaps\u0131yorsa, sayfadaki en geni\u015f aral\u0131\u011f\u0131 her varyant\u0131n kapasitesi olarak kabul etmek yerine, se\u00e7ilen sat\u0131r\u0131 i\u015faretleyin.<\/p>\n\n<h2 class=\"wp-block-heading\">Tedarik S\u00fcrecinde Yap\u0131lan Kontrol De\u011fi\u015fiklikleri<\/h2>\n\n<p class=\"wp-block-paragraph\">Tedarik\u00e7iler tekliflerini haz\u0131rlarken ba\u015fvuru kayd\u0131n\u0131 dondurulmu\u015f halde tutun. Gerilim, y\u00fck, \u00e7al\u0131\u015fma ko\u015fulu, ar\u0131za seviyesi, muhafaza veya \u00e7al\u0131\u015fma y\u00f6ntemi gibi bilgilerde de\u011fi\u015fiklik olmas\u0131 durumunda, g\u00fcncellenmi\u015f bir kay\u0131t yay\u0131nlay\u0131n ve her tedarik\u00e7iden aday \u00fcr\u00fcn\u00fc yeniden onaylamas\u0131n\u0131 isteyin. Aksi takdirde, e-posta konusu ve \u00fcr\u00fcn grubu de\u011fi\u015fmemi\u015f olsa bile, sat\u0131n alma birimi farkl\u0131 gereksinimler i\u00e7in haz\u0131rlanm\u0131\u015f teklifleri kar\u015f\u0131la\u015ft\u0131rabilir.<\/p>\n\n<p class=\"wp-block-paragraph\">Ayn\u0131 kural\u0131 ikame \u00fcr\u00fcnler i\u00e7in de uygulay\u0131n. Fiyat veya temin edilebilirlik nedeniyle \u00f6nerilen bir ikame \u00fcr\u00fcn, kendine ait sipari\u015f kodu ve destekleyici belgelerle birlikte teknik inceleme a\u015famas\u0131na geri g\u00f6nderilir. Yaln\u0131zca nominal ak\u0131m, \u00fcr\u00fcn \u015fekli veya montaj y\u00f6nteminin orijinal adaya benzemesi nedeniyle bunu onaylamay\u0131n. \u0130kame i\u015flemi, ancak gerekli i\u015flevler ve ko\u015fullar yeniden kontrol edildi\u011finde tamamlanm\u0131\u015f say\u0131l\u0131r.<\/p>\n\n<h2 class=\"wp-block-heading\">\u0130hale S\u00fcrecinde S\u0131k G\u00f6r\u00fclen Hatalar<\/h2>\n\n<ul class=\"wp-block-list\"><li>Uygulama ba\u011flam\u0131n\u0131 tan\u0131mlamadan, tek bir ba\u015fl\u0131k derecelendirmesinden MPCB\u2019yi se\u00e7mek.<\/li><li>Kapsam\u0131n\u0131 teyit etmeden kom\u015fu bir modele ait bir \u015fema, e\u011fri veya aksesuar tablosunu kullanmak.<\/li><li>Bir \u00fcr\u00fcn kategorisi sayfas\u0131n\u0131 veya pazarlama g\u00f6rselini, tam model kan\u0131t\u0131 olarak de\u011ferlendirmek.<\/li><li>Sadece cihazdan olu\u015fan bir teklif ile montajl\u0131 veya aksesuarlar dahil bir teklifi kar\u015f\u0131la\u015ft\u0131rma.<\/li><li>Ticari teklifin revize edilmesi s\u0131ras\u0131nda, hen\u00fcz \u00e7\u00f6z\u00fclmemi\u015f bir teknik konunun ortadan kalkmas\u0131na izin vermek.<\/li><\/ul>\n\n<p class=\"wp-block-paragraph\">Ticari kar\u015f\u0131la\u015ft\u0131rma yapmadan \u00f6nce bu hatalar\u0131 giderin. Teknik inceleme uzman\u0131, haf\u0131zas\u0131na g\u00fcvenmek zorunda kalmadan kabul edilen her bir beyan\u0131 proje kayd\u0131na veya ilgili belgeye kadar izleyebilmelidir. B\u00f6ylelikle, sat\u0131n alma birimi, sipari\u015f verildikten sonra se\u00e7im s\u00fcrecini yeniden ba\u015flatmak yerine, fiyat, miktar, var\u0131\u015f yeri ve teslim s\u00fcresini sabit bir teknik referans noktas\u0131 ile kar\u015f\u0131la\u015ft\u0131rabilir.<\/p>\n\n<h2 class=\"wp-block-heading\">Tedarik\u00e7i Tekliflerini Kar\u015f\u0131la\u015ft\u0131rma Y\u00f6ntemleri<\/h2>\n\n<p class=\"wp-block-paragraph\">Her bir MPCB teklifini, dondurulmu\u015f bir ba\u015fvuru kayd\u0131yla kar\u015f\u0131la\u015ft\u0131r\u0131n. Birka\u00e7 varyanttan en iyi rakamlar\u0131 birle\u015ftirmeyin veya teklif edilen sipari\u015f kodunun derecesi olarak bir \u00fcr\u00fcn ailesinin en y\u00fcksek de\u011ferini kabul etmeyin. Tedarik ekibinin iki teklifin ger\u00e7ekten e\u015fde\u011fer olup olmad\u0131\u011f\u0131n\u0131 g\u00f6rebilmesi i\u00e7in, her bir de\u011ferin yan\u0131nda belge revizyonunu, test ko\u015fullar\u0131n\u0131 ve \u00e7\u00f6z\u00fclmemi\u015f alanlar\u0131 belirtin.<\/p>\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Kar\u015f\u0131la\u015ft\u0131rma noktas\u0131<\/th><th>Gerekli kan\u0131tlar<\/th><th>Kabul etmeyin<\/th><\/tr><\/thead><tbody><tr><td>Ayarlama<\/td><td>Exact band, motor ak\u0131m\u0131n\u0131 i\u00e7erir; ayarlama y\u00f6ntemi belirtilmi\u015ftir<\/td><td>Yaln\u0131zca aileye y\u00f6nelik mevcut \u00fcr\u00fcn yelpazesi<\/td><\/tr><tr><td>Kesinti<\/td><td>Proje gerilimi ve konfig\u00fcrasyonunda kesme kapasitesi<\/td><td>Ko\u015fulsuz tek bir kA de\u011feri<\/td><\/tr><tr><td>\u0130\u015flevler<\/td><td>Gezi ve operat\u00f6r i\u015flevleri belgelendi<\/td><td>MPCB ad\u0131ndan hareketle varsay\u0131lm\u0131\u015ft\u0131r<\/td><\/tr><tr><td>Kombinasyon<\/td><td>Talep edildi\u011finde, test edilmi\u015f tam kombinasyon kayd\u0131<\/td><td>Ortak marka veya uyumlu amper aral\u0131\u011f\u0131<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n<figure data-spectra-id=\"spectra-efa1e18f-ee08-4af9-bbd4-46d41035ef3a\" class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-037-BODY-02-r2.webp\" alt=\"MPCB, kontakt\u00f6r ve yukar\u0131 ak\u0131m koruma kay\u0131tlar\u0131 ile kesin koordinasyon tablosu aras\u0131ndaki ili\u015fki\" class=\"wp-image-1272\" width=\"1400\" height=\"1050\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-037-BODY-02-r2.webp 1400w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-037-BODY-02-r2-600x450.webp 600w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-037-BODY-02-r2-300x225.webp 300w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-037-BODY-02-r2-1024x768.webp 1024w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-037-BODY-02-r2-768x576.webp 768w\" sizes=\"auto, (max-width: 1400px) 100vw, 1400px\" \/><figcaption class=\"wp-element-caption\">Bir koordinasyon talebi i\u00e7in, her bir bile\u015fen kodunu tam olarak belirten tek bir belge gereklidir.<\/figcaption><\/figure>\n\n\n<p class=\"wp-block-paragraph\">Bir teklif, teknik a\u00e7\u0131dan eksik olsa bile ticari a\u00e7\u0131dan cazip kalabilir. Eksik verileri \u201challetilmesi gereken i\u015f\u201d olarak i\u015faretleyin ve tedarik\u00e7iden ilgili sayfan\u0131n, \u00e7izimin veya bile\u015fen tablosunun tam kopyas\u0131n\u0131 isteyin. Fiyat ve teslim s\u00fcresi, ancak teknik kapsam netle\u015ftirildikten sonra kar\u015f\u0131la\u015ft\u0131r\u0131lmal\u0131d\u0131r. Bu, daha d\u00fc\u015f\u00fck maliyetli ancak daha s\u0131n\u0131rl\u0131 bir teklifin, eksiksiz ve belgelenmi\u015f bir \u00e7\u00f6z\u00fcmle e\u015fde\u011fermi\u015f gibi g\u00f6r\u00fcnmesini engeller.<\/p>\n\n<h2 class=\"wp-block-heading\">Karar \u0130\u015f Ak\u0131\u015f\u0131<\/h2>\n\n<ul class=\"wp-block-list\"><li>Motor tip plakas\u0131 ve \u00e7al\u0131\u015fma ko\u015fulu bilgilerini dondurun.<\/li><li>MPCB'nin bulundu\u011fu noktadaki olas\u0131 ar\u0131za ak\u0131m\u0131n\u0131 belirleyin.<\/li><li>Model s\u0131n\u0131rlar\u0131n\u0131 a\u015fmadan bir aday ayarlama aral\u0131\u011f\u0131 se\u00e7in.<\/li><li>Tam sipari\u015f kodu i\u00e7in gerilimi, kesme kapasitesini ve devre kesme davran\u0131\u015f\u0131n\u0131 do\u011frulay\u0131n.<\/li><li>Terminalleri, montaj\u0131, aksesuarlar\u0131 ve \u00e7evresel s\u0131n\u0131r de\u011ferleri kontrol edin.<\/li><li>\u00d6nerilen herhangi bir kontakt\u00f6r veya mar\u015f motoru kombinasyonu i\u00e7in kesin koordinasyon kan\u0131t\u0131 talep edin.<\/li><\/ul>\n\n<p class=\"wp-block-paragraph\">Her a\u015famada, proje girdileri ile tedarik\u00e7inin sundu\u011fu kan\u0131tlar aras\u0131ndaki s\u0131n\u0131r\u0131 koruyun. Proje ekibi, uygulamay\u0131 ve gerekli i\u015flevleri tan\u0131mlar; tedarik\u00e7i ise kesin bir \u00fcr\u00fcn belirler ve ilgili belgeleri sunar. Taraflardan hi\u00e7biri, g\u00f6r\u00fcn\u00fc\u015ften, benzer bir modelden veya ortak bir genel derecelendirme notundan \u00e7\u0131kar\u0131mlarda bulunarak kan\u0131t eksikli\u011fini gidermemelidir.<\/p>\n\n<h2 class=\"wp-block-heading\">Teklif Talebi Haz\u0131rl\u0131k Kontrol Listesi<\/h2>\n\n<p class=\"wp-block-paragraph\">Motor koruma devre kesici se\u00e7imi k\u0131lavuzu i\u00e7in faydal\u0131 bir teklif talebi (RFQ), yan\u0131tlanmas\u0131 kolay olacak kadar \u00f6zl\u00fc, ancak gizli varsay\u0131mlar\u0131 \u00f6nleyecek kadar kapsaml\u0131 olmal\u0131d\u0131r. Mevcut proje belgelerini ekleyin ve bilinmeyen de\u011ferleri soru olarak belirtin. Tedarik\u00e7iden, genel bir \u00fcr\u00fcn ailesi \u00f6nerisi yerine, sipari\u015f verilebilecek kesin bir kodla yan\u0131t vermesini isteyin.<\/p>\n\n<ul class=\"wp-block-list\"><li>Motor g\u00fcc\u00fc ve nominal gerilim\/ak\u0131m<\/li><li>Besleme frekans\u0131, faz ve \u00e7al\u0131\u015ft\u0131rma y\u00f6ntemi<\/li><li>Beklenen k\u0131sa devre ak\u0131m\u0131<\/li><li>Gerekli ayar aral\u0131\u011f\u0131 ve koruma i\u015flevleri<\/li><li>Montaj, muhafaza ve ortam ko\u015fullar\u0131<\/li><li>Tam model kodu ve dok\u00fcmantasyon s\u00fcr\u00fcm\u00fc<\/li><li>Miktar ve var\u0131\u015f yeri<\/li><\/ul>\n\n<p class=\"wp-block-paragraph\">G\u00fcncel teknik veri sayfas\u0131 s\u00fcr\u00fcm\u00fcn\u00fc talep edin ve herhangi bir sertifikasyon, koordinasyon veya uyumluluk iddias\u0131n\u0131n kapsam\u0131n\u0131 belirleyin. Yan\u0131tta bir alternatif \u00f6neriliyorsa, o alternatif i\u00e7in de ayn\u0131 kan\u0131t setini talep edin. Ticari \u015fartlar\u0131n \u00e7\u00f6z\u00fclmemi\u015f m\u00fchendislik sorunlar\u0131n\u0131 g\u00f6lgelememesi i\u00e7in, teknik girdilerin ard\u0131ndan miktar\u0131 ve var\u0131\u015f yerini kaydedin.<\/p>\n\n<h2 class=\"wp-block-heading\">Sipari\u015fin Serbest B\u0131rak\u0131lmas\u0131ndan \u00d6nceki Durdurma Ko\u015fullar\u0131<\/h2>\n\n<p class=\"wp-block-paragraph\">Yay\u0131n a\u00e7\u0131s\u0131ndan kritik bir girdi bilinmiyorsa, belirtilen model belirsizse veya gerekli bir derecelendirme yaln\u0131zca ba\u015fka bir \u00fcreticinin belgesiyle destekleniyorsa, sipari\u015fi onaylamay\u0131n. Ayr\u0131ca, bir kombinasyon talebinde kesin bile\u015fen kodlar\u0131 eksikse veya bir \u015fema farkl\u0131 \u00fcr\u00fcn ailelerinde yeniden kullan\u0131l\u0131yorsa da i\u015flemi durdurun. Bunlar, editoryal ayr\u0131nt\u0131lar de\u011fil, kan\u0131t eksiklikleridir.<\/p>\n\n<p class=\"wp-block-paragraph\">Nihai onay kayd\u0131nda, se\u00e7ilen \u00f6\u011fenin ne i\u015fe yarad\u0131\u011f\u0131, kapsam\u0131 d\u0131\u015f\u0131nda kalan unsurlar ve karar\u0131 destekleyen belgelerin tam olarak hangileri oldu\u011fu belirtilmelidir. Uygulama, g\u00f6rev, ortam veya \u00f6nerilen modelde de\u011fi\u015fiklik olmas\u0131 durumunda, \u00f6nceki sonucu aynen devralmak yerine ilgili kontrolleri yeniden ba\u015flat\u0131n.<\/p>\n\n<h2 class=\"wp-block-heading\">S\u0131k Sorulan Sorular<\/h2>\n\n<h3 class=\"wp-block-heading\">Bir MPCB\u2019nin boyutunu sadece motorun kW de\u011ferine g\u00f6re belirleyebilir miyim?<\/h3>\n\n<p class=\"wp-block-paragraph\">Hay\u0131r. Gerilim, ak\u0131m, \u00e7al\u0131\u015ft\u0131rma y\u00fck\u00fc, ar\u0131za seviyesi ve \u00fcreticinin kesin verileri de gereklidir.<\/p>\n\n<h3 class=\"wp-block-heading\">MPCB, kontakt\u00f6r ihtiyac\u0131n\u0131 ortadan kald\u0131r\u0131r m\u0131?<\/h3>\n\n<p class=\"wp-block-paragraph\">Otomatik olarak de\u011fil. Anahtarlama ve kontrol kapsam\u0131, koruma i\u015flevlerinden ayr\u0131 olarak tan\u0131mlanmal\u0131d\u0131r.<\/p>\n\n<h3 class=\"wp-block-heading\">Ak\u0131m aral\u0131klar\u0131n\u0131n e\u015fle\u015fmesi, koordinasyonu kan\u0131tlayabilir mi?<\/h3>\n\n<p class=\"wp-block-paragraph\">Hay\u0131r. Koordinasyon talepleri i\u00e7in, \u00fcretici taraf\u0131ndan test edilmi\u015f kesin bir kombinasyon kayd\u0131 gereklidir.<\/p>\n\n<h2 class=\"wp-block-heading\">\u0130lgili RITOKS \u00dcr\u00fcnleri ve K\u0131lavuzlar<\/h2>\n\n<p class=\"wp-block-paragraph\">Bu ba\u011flant\u0131lar\u0131 ayr\u0131 kategori, \u00fcr\u00fcn ve e\u011fitim kay\u0131tlar\u0131 olarak kullan\u0131n. Ba\u011flamsal bir ba\u011flant\u0131, kar\u015f\u0131l\u0131kl\u0131 de\u011fi\u015ftirilebilirlik, uyumluluk veya koordineli bir birle\u015fim iddias\u0131nda bulunmaz.<\/p>\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/ritoks.com\/tr\/product-category\/ac-power-protection\/motor-protection-circuit-breakers\/\">MPCB \u00fcr\u00fcn kategorisi<\/a><\/p>\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/ritoks.com\/tr\/products\/gymp7-three-phase-motor-protection-circuit-breakers\/\">GYMP7 motor koruma devre kesicileri<\/a><\/p>\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/ritoks.com\/tr\/mpcb-vs-overload-relay-vs-mcb\/\">MPCB, termal a\u015f\u0131r\u0131 y\u00fck r\u00f6lesi ve MCB kar\u015f\u0131la\u015ft\u0131rmas\u0131<\/a><\/p>\n\n<h2 class=\"wp-block-heading\">Teknik Kaynaklar<\/h2>\n\n<p class=\"wp-block-paragraph\">A\u015fa\u011f\u0131daki g\u00fcvenilir kaynaklar, yaln\u0131zca a\u015fa\u011f\u0131da belirtilen genel kavramlar\u0131 desteklemektedir. Bu kaynaklardaki \u00fcr\u00fcn de\u011ferleri, \u015femalar, kombinasyonlar ve onaylar, RITOKS \u00fcr\u00fcnlerine uygulanmaz.<\/p>\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/electrification.us.abb.com\/control_pdf\" target=\"_blank\" rel=\"noopener\">ABB, Kontrol Katalo\u011fu: IEC Manuel Motor Ba\u015flat\u0131c\u0131lar\u0131<\/a><\/p>\n\n<p class=\"wp-block-paragraph\">Manuel motor devre ba\u015flat\u0131c\u0131lar\u0131, kontakt\u00f6rler ve a\u015f\u0131r\u0131 y\u00fck r\u00f6leleri aras\u0131ndaki ayr\u0131m\u0131 ve kesin koordinasyon tablolar\u0131n\u0131n kullan\u0131lmas\u0131n\u0131n gereklili\u011fini destekler. ABB model verileri GYMP7\u2019ye aktar\u0131lmaz.<\/p>\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/library.e.abb.com\/public\/5e32edbf30254c17b51cf5dd9ba841ab\/1SAC200017M0002_en_C_Contactors%20and%20Overload%20relays%20guide.pdf\" target=\"_blank\" rel=\"noopener\">ABB, Kontakt\u00f6rler ve A\u015f\u0131r\u0131 Y\u00fck R\u00f6leleri K\u0131lavuzu<\/a><\/p>\n\n<p class=\"wp-block-paragraph\">Ayr\u0131 a\u015f\u0131r\u0131 y\u00fck, k\u0131sa devre koruma cihaz\u0131 ve koordinasyon kararlar\u0131n\u0131 destekler. Bu kombinasyonlar yaln\u0131zca ABB \u00fcr\u00fcnlerine \u00f6zeldir.<\/p>\n\n<h2 class=\"wp-block-heading\">Belirli Bir Modelin \u0130ncelenmesini Talep Et<\/h2>\n\n<p class=\"wp-block-paragraph\">Kaydedilen uygulama gereksinimlerini, belgelerle ilgili kesin sorular\u0131, miktar\u0131 ve teslimat adresini RITOKS ileti\u015fim formu arac\u0131l\u0131\u011f\u0131yla g\u00f6nderin. Bir RFQ, kesin model incelemesi talep eder; bu k\u0131lavuz, kablolama tasar\u0131m\u0131n\u0131, kurulumu veya otomatik ikameyi onaylamaz.<\/p>\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/ritoks.com\/tr\/contact-us\/\">RITOKS ile ileti\u015fime ge\u00e7in<\/a><\/p>","protected":false},"excerpt":{"rendered":"<p>Motor ak\u0131m\u0131, devre kesme aral\u0131\u011f\u0131, ar\u0131za seviyesi ve kesin koordinasyon kan\u0131tlar\u0131na g\u00f6re bir MPCB se\u00e7in. Uyumluluk varsay\u0131m\u0131 yapmadan eksiksiz bir teklif talebi haz\u0131rlay\u0131n.<\/p>","protected":false},"author":1,"featured_media":1270,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"no-sidebar","site-content-layout":"page-builder","ast-site-content-layout":"full-width-container","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"disabled","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"disabled","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ritoks_resource_detail_renderer":"viox","ritoks_resource_product_cat_term_id":0,"footnotes":""},"categories":[65],"tags":[],"class_list":["post-1269","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-motor-control-protection"],"acf":[],"spectra_blocks_featured_image_url":{"thumbnail":{"url":"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-037-HERO-01-r2-150x150.webp","width":150,"height":150},"medium":{"url":"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-037-HERO-01-r2-300x169.webp","width":300,"height":169},"medium_large":{"url":"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-037-HERO-01-r2-768x432.webp","width":768,"height":432},"large":{"url":"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-037-HERO-01-r2-1024x576.webp","width":1024,"height":576},"full":{"url":"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-037-HERO-01-r2.webp","width":1600,"height":900}},"spectra_blocks_author_info":{"display_name":"RITOKS","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/6d7d0fc73468198f994ab13ef6eb6558c53b6ed1ad86364d5165efe8bdf8eb4a?s=96&d=mm&r=g","author_link":"https:\/\/ritoks.com\/tr\/author\/dazzlingwqbgmail-com\/","description":""},"_links":{"self":[{"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/posts\/1269","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/comments?post=1269"}],"version-history":[{"count":2,"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/posts\/1269\/revisions"}],"predecessor-version":[{"id":2352,"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/posts\/1269\/revisions\/2352"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/media\/1270"}],"wp:attachment":[{"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/media?parent=1269"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/categories?post=1269"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/tags?post=1269"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}