{"id":1302,"date":"2026-09-21T15:38:44","date_gmt":"2026-09-21T15:38:44","guid":{"rendered":"https:\/\/ritoks.com\/?p=1302"},"modified":"2026-09-21T15:38:44","modified_gmt":"2026-09-21T15:38:44","slug":"10x38-vs-10x65-dc-fuse-links","status":"publish","type":"post","link":"https:\/\/ritoks.com\/tr\/10x38-vs-10x65-dc-fuse-links\/","title":{"rendered":"10\u00d738 ve 10\u00d765 DC Sigorta Ba\u011flant\u0131lar\u0131: Tek Fark Boyut De\u011fil"},"content":{"rendered":"<p class=\"wp-block-paragraph\">The labels 10&#215;38 and 10&#215;65 describe nominal fuse-link formats, not complete electrical specifications. A buyer must compare voltage, current, utilization category, breaking and time-current evidence, dimensions and the supported holder before choosing between two links.<\/p>\n\n<p class=\"wp-block-paragraph\">Bu makale, format kar\u015f\u0131la\u015ft\u0131rmas\u0131n\u0131 i\u00e7ermektedir. DC sigorta se\u00e7im k\u0131lavuzunun yerini almaz, iki format\u0131n birbirinin yerine kullan\u0131labilece\u011fini belirtmez veya herhangi bir ba\u011flant\u0131n\u0131n ayn\u0131 boyuttaki herhangi bir yuvaya uyaca\u011f\u0131n\u0131 ifade etmez.<\/p>\n\n\n<figure data-spectra-id=\"spectra-6e881eb7-d048-4e23-817e-80fbb936f1ee\" class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-015-HERO-01.webp\" alt=\"DC sigortalar\u0131n\u0131n fiziksel formatlar\u0131n\u0131n kar\u015f\u0131la\u015ft\u0131r\u0131lmas\u0131\" class=\"wp-image-1280\" width=\"1600\" height=\"900\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-015-HERO-01.webp 1600w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-015-HERO-01-600x338.webp 600w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-015-HERO-01-300x169.webp 300w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-015-HERO-01-1024x576.webp 1024w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-015-HERO-01-768x432.webp 768w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-015-HERO-01-1536x864.webp 1536w\" sizes=\"auto, (max-width: 1600px) 100vw, 1600px\" \/><\/figure>\n\n\n<h2 class=\"wp-block-heading\">Sat\u0131n Alma Karar\u0131: \u00d6zet<\/h2>\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Karar girdisi<\/th><th>Al\u0131c\u0131 bunu teyit etmelidir<\/th><th>Gerekli kan\u0131tlar<\/th><\/tr><\/thead><tbody><tr><td>Ba\u015fvuru<\/td><td>PV veya di\u011fer tan\u0131mlanm\u0131\u015f DC \u00e7al\u0131\u015fma ko\u015fullar\u0131<\/td><td>Kesin kullan\u0131m kategorisi<\/td><\/tr><tr><td>Gerilim<\/td><td>Maksimum devre gerilimi<\/td><td>Tam ba\u011flant\u0131 DC de\u011ferleri<\/td><\/tr><tr><td>Mevcut<\/td><td>Normal ak\u0131m ve tasar\u0131m ko\u015fullar\u0131<\/td><td>Kesin ba\u011flant\u0131 derecesi ve e\u011frisi<\/td><\/tr><tr><td>Ar\u0131za g\u00f6rev s\u00fcresi<\/td><td>Olas\u0131 ar\u0131za durumlar\u0131<\/td><td>Ar\u0131za ve i\u015fletim verileri<\/td><\/tr><tr><td>Montaj<\/td><td>Tutucu kodu, terminaller ve ortam<\/td><td>Belgelenmi\u015f ba\u011flant\u0131 sahibi e\u015fle\u015ftirmesi<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n<figure data-spectra-id=\"spectra-6b0d8574-cf63-44a5-8694-2a771c2577fc\" class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-015-BODY-01.webp\" alt=\"10x38 ile 10x65 sigorta ba\u011flant\u0131 elemanlar\u0131na ili\u015fkin kan\u0131t gereklilikleri\" class=\"wp-image-1281\" width=\"1400\" height=\"1050\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-015-BODY-01.webp 1400w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-015-BODY-01-600x450.webp 600w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-015-BODY-01-300x225.webp 300w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-015-BODY-01-1024x768.webp 1024w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-015-BODY-01-768x576.webp 768w\" sizes=\"auto, (max-width: 1400px) 100vw, 1400px\" \/><figcaption class=\"wp-element-caption\">Physical size alone does not prove that 10&#215;38 and 10&#215;65 fuse links are interchangeable.<\/figcaption><\/figure>\n\n\n<h2 class=\"wp-block-heading\">Bi\u00e7imi Tek Bir Alan Olarak De\u011ferlendir<\/h2>\n\n<p class=\"wp-block-paragraph\">Bir kartu\u015fun boyutlar\u0131, mekanik seriyi belirlemeye yard\u0131mc\u0131 olur; ancak nominal gerilimi, ak\u0131m aral\u0131\u011f\u0131n\u0131, kullan\u0131m kategorisini veya kesme performans\u0131n\u0131 g\u00f6stermez. Ayn\u0131 boyutlara sahip iki ba\u011flant\u0131 par\u00e7as\u0131 farkl\u0131 i\u015flevler g\u00f6rebilir ve farkl\u0131 formatlar aras\u0131nda ak\u0131m de\u011ferleri a\u00e7\u0131s\u0131ndan \u00f6rt\u00fc\u015fme olabilir.<\/p>\n\n<p class=\"wp-block-paragraph\">Kar\u015f\u0131la\u015ft\u0131rmaya devre ve koruma hedefi ile ba\u015flay\u0131n. Maksimum gerilimi, normal ak\u0131m\u0131, ar\u0131za ko\u015fullar\u0131n\u0131 ve beklenen sigorta kategorisini kaydedin. Ancak bundan sonra, bu format\u0131 kullanarak aday ba\u011flant\u0131 elemanlar\u0131n\u0131 ve tutucular\u0131 daralt\u0131n.<\/p>\n\n<h2 class=\"wp-block-heading\">Elektrik Kay\u0131tlar\u0131n\u0131 Tam Olarak Kar\u015f\u0131la\u015ft\u0131r\u0131n<\/h2>\n\n<p class=\"wp-block-paragraph\">Read the complete model row for each link. Keep voltage, current, category, breaking data and operating curve together. Do not combine a 10&#215;65 voltage claim with a 10&#215;38 curve or assume the longer body always provides a universally higher rating.<\/p>\n\n<p class=\"wp-block-paragraph\">Mersen\u2019in PV koruma k\u0131lavuzu, PV sigorta ba\u011flant\u0131lar\u0131n\u0131n neden belirli bir DC uygulama ba\u011flam\u0131nda de\u011ferlendirildi\u011fini a\u00e7\u0131klamaktad\u0131r. Bu k\u0131lavuz, do\u011frulama s\u00fcrecini destekler ancak RITOKS ba\u011flant\u0131lar\u0131n\u0131 sertifikaland\u0131ramaz. Yay\u0131nlanan \u00fcr\u00fcn ve \u00fcretici kay\u0131tlar\u0131, \u00f6nerilen her sipari\u015f kodunu ayr\u0131nt\u0131l\u0131 olarak d\u00fczenler.<\/p>\n\n<h2 class=\"wp-block-heading\">Tutucuyu Ayr\u0131 Olarak Do\u011frulay\u0131n<\/h2>\n\n<p class=\"wp-block-paragraph\">Tutucu da nominal de\u011ferleri belirlenmi\u015f bir bile\u015fendir. Gerilim, ak\u0131m, terminal, montaj ve \u00e7evresel verilerinin yan\u0131 s\u0131ra \u00fcretici taraf\u0131ndan belirtilen ba\u011flant\u0131 boyutlar\u0131n\u0131 da do\u011frulay\u0131n. Yaln\u0131zca fiziksel olarak tak\u0131lmas\u0131, elektriksel montaj\u0131n tam olarak ger\u00e7ekle\u015ftirildi\u011fini kan\u0131tlamaz.<\/p>\n\n<p class=\"wp-block-paragraph\">De\u011fi\u015ftirme i\u015flemleri i\u00e7in, yedek par\u00e7ay\u0131 kabul etmeden \u00f6nce monte edilmi\u015f tutucunun kodunu ve onaylanm\u0131\u015f ba\u011flant\u0131 par\u00e7as\u0131n\u0131 belirleyin. Yeni bir montaj i\u00e7in, her iki sipari\u015f kodunu ve her iki teknik veri sayfas\u0131n\u0131 talep edin. Tedarik\u00e7i, ama\u00e7lanan e\u015fle\u015ftirmeyi belirtemezse, teklif eksik kal\u0131r.<\/p>\n\n<h2 class=\"wp-block-heading\">RITOKS \u00d6rneklerini Birle\u015ftirmeden Kullanma<\/h2>\n\n<p class=\"wp-block-paragraph\">RITOKS publishes a 10&#215;38 1000V gPV family and a separate 10&#215;65 1500V gPV family. Those page titles describe distinct verified product records. They do not create a universal 1000-1500V range shared by both sizes.<\/p>\n\n<p class=\"wp-block-paragraph\">\u0130htiyac\u0131n\u0131z olan sat\u0131rlar\u0131n ak\u0131m, gerilim, fiziksel \u00f6zellikler ve tutucu bilgilerini kar\u015f\u0131la\u015ft\u0131r\u0131n. Uygulama fotovoltaik de\u011filse, gPV \u00f6rneklerinin uygun oldu\u011funu varsaymay\u0131n. Ger\u00e7ek devreye uygun do\u011fru sigorta kategorisini ve ilgili belgeleri talep edin.<\/p>\n\n<h2 class=\"wp-block-heading\">Onaydan \u00d6nce Bir Kan\u0131t Dosyas\u0131 Haz\u0131rlay\u0131n<\/h2>\n\n<p class=\"wp-block-paragraph\">\u00d6nerilen DC Sigorta sipari\u015f kodu i\u00e7in bir inceleme tablosu olu\u015fturun. Uygulama verilerini sol s\u00fctuna, tedarik\u00e7iye ait kan\u0131tlar\u0131 ise sa\u011f s\u00fctuna yaz\u0131n. En az\u0131ndan uygulama, gerilim, ak\u0131m, ar\u0131za y\u00fck\u00fc ve montaj bilgilerini kay\u0131t alt\u0131nda tutun. Bu sayede hangi bilgilerin projeden, hangi beyanlar\u0131n ise \u00fcreticiden geldi\u011fi net bir \u015fekilde anla\u015f\u0131l\u0131r.<\/p>\n\n<p class=\"wp-block-paragraph\">Kararda kullan\u0131lan veri sayfalar\u0131n\u0131n, \u00e7izimlerin ve tablolar\u0131n tam kopyalar\u0131n\u0131 ekleyin. Bunlar\u0131n revizyon veya eri\u015fim tarihlerini kaydedin ve belirtilen modele ait sat\u0131r\u0131 vurgulay\u0131n. Bir sat\u0131\u015f e-postas\u0131 kapsam\u0131 netle\u015ftirebilir; ancak karar, bir derecelendirme, ba\u011flant\u0131, devre kesme \u00f6zelli\u011fi, termal s\u0131n\u0131r veya test edilmi\u015f bir kombinasyona ba\u011fl\u0131 oldu\u011funda, teknik belgenin yerini sessizce almamal\u0131d\u0131r.<\/p>\n\n<p class=\"wp-block-paragraph\">Her bir ba\u011flant\u0131l\u0131 de\u011ferin ayn\u0131 sipari\u015f edilebilir konfig\u00fcrasyonu tan\u0131mlad\u0131\u011f\u0131n\u0131 kontrol edin. Benzer model isimleri genellikle ayn\u0131 g\u00f6vdeyi payla\u015f\u0131rken, kontrol beslemesi, ak\u0131m aral\u0131\u011f\u0131, kutuplar, terminaller, aksesuarlar veya \u00e7evresel s\u0131n\u0131rlar a\u00e7\u0131s\u0131ndan farkl\u0131l\u0131k g\u00f6sterebilir. Bir belge birka\u00e7 varyant\u0131 kaps\u0131yorsa, sayfadaki en geni\u015f aral\u0131\u011f\u0131 her varyant\u0131n kapasitesi olarak kabul etmek yerine, se\u00e7ilen sat\u0131r\u0131 i\u015faretleyin.<\/p>\n\n<h2 class=\"wp-block-heading\">Tedarik S\u00fcrecinde Yap\u0131lan Kontrol De\u011fi\u015fiklikleri<\/h2>\n\n<p class=\"wp-block-paragraph\">Tedarik\u00e7iler tekliflerini haz\u0131rlarken ba\u015fvuru kayd\u0131n\u0131 dondurulmu\u015f halde tutun. Gerilim, y\u00fck, \u00e7al\u0131\u015fma ko\u015fulu, ar\u0131za seviyesi, muhafaza veya \u00e7al\u0131\u015fma y\u00f6ntemi gibi bilgilerde de\u011fi\u015fiklik olmas\u0131 durumunda, g\u00fcncellenmi\u015f bir kay\u0131t yay\u0131nlay\u0131n ve her tedarik\u00e7iden aday \u00fcr\u00fcn\u00fc yeniden onaylamas\u0131n\u0131 isteyin. Aksi takdirde, e-posta konusu ve \u00fcr\u00fcn grubu de\u011fi\u015fmemi\u015f olsa bile, sat\u0131n alma birimi farkl\u0131 gereksinimler i\u00e7in haz\u0131rlanm\u0131\u015f teklifleri kar\u015f\u0131la\u015ft\u0131rabilir.<\/p>\n\n<p class=\"wp-block-paragraph\">Ayn\u0131 kural\u0131 ikame \u00fcr\u00fcnler i\u00e7in de uygulay\u0131n. Fiyat veya temin edilebilirlik nedeniyle \u00f6nerilen bir ikame \u00fcr\u00fcn, kendine ait sipari\u015f kodu ve destekleyici belgelerle birlikte teknik inceleme a\u015famas\u0131na geri g\u00f6nderilir. Yaln\u0131zca nominal ak\u0131m, \u00fcr\u00fcn \u015fekli veya montaj y\u00f6nteminin orijinal adaya benzemesi nedeniyle bunu onaylamay\u0131n. \u0130kame i\u015flemi, ancak gerekli i\u015flevler ve ko\u015fullar yeniden kontrol edildi\u011finde tamamlanm\u0131\u015f say\u0131l\u0131r.<\/p>\n\n<h2 class=\"wp-block-heading\">\u0130hale S\u00fcrecinde S\u0131k G\u00f6r\u00fclen Hatalar<\/h2>\n\n<ul class=\"wp-block-list\"><li>Uygulama ba\u011flam\u0131n\u0131 tan\u0131mlamadan, tek bir ana derecelendirme kategorisinden DC sigortas\u0131 se\u00e7mek.<\/li><li>Kapsam\u0131n\u0131 teyit etmeden kom\u015fu bir modele ait bir \u015fema, e\u011fri veya aksesuar tablosunu kullanmak.<\/li><li>Bir \u00fcr\u00fcn kategorisi sayfas\u0131n\u0131 veya pazarlama g\u00f6rselini, tam model kan\u0131t\u0131 olarak de\u011ferlendirmek.<\/li><li>Sadece cihazdan olu\u015fan bir teklif ile montajl\u0131 veya aksesuarlar dahil bir teklifi kar\u015f\u0131la\u015ft\u0131rma.<\/li><li>Ticari teklifin revize edilmesi s\u0131ras\u0131nda, hen\u00fcz \u00e7\u00f6z\u00fclmemi\u015f bir teknik konunun ortadan kalkmas\u0131na izin vermek.<\/li><\/ul>\n\n<p class=\"wp-block-paragraph\">Ticari kar\u015f\u0131la\u015ft\u0131rma yapmadan \u00f6nce bu hatalar\u0131 giderin. Teknik inceleme uzman\u0131, haf\u0131zas\u0131na g\u00fcvenmek zorunda kalmadan kabul edilen her bir beyan\u0131 proje kayd\u0131na veya ilgili belgeye kadar izleyebilmelidir. B\u00f6ylelikle, sat\u0131n alma birimi, sipari\u015f verildikten sonra se\u00e7im s\u00fcrecini yeniden ba\u015flatmak yerine, fiyat, miktar, var\u0131\u015f yeri ve teslim s\u00fcresini sabit bir teknik referans noktas\u0131 ile kar\u015f\u0131la\u015ft\u0131rabilir.<\/p>\n\n<h2 class=\"wp-block-heading\">Tedarik\u00e7i Tekliflerini Kar\u015f\u0131la\u015ft\u0131rma Y\u00f6ntemleri<\/h2>\n\n<p class=\"wp-block-paragraph\">Her bir DC Sigorta teklifini, tek bir sabitlenmi\u015f ba\u015fvuru kayd\u0131yla kar\u015f\u0131la\u015ft\u0131r\u0131n. Birka\u00e7 farkl\u0131 varyanttan en iyi de\u011ferleri birle\u015ftirmeyin veya teklif edilen sipari\u015f kodunun de\u011ferini belirlerken \u00fcr\u00fcn ailesinin maksimum de\u011ferini esas almay\u0131n. Sat\u0131n alma ekibinin iki teklifin ger\u00e7ekten e\u015fde\u011fer olup olmad\u0131\u011f\u0131n\u0131 g\u00f6rebilmesi i\u00e7in, her bir de\u011ferin yan\u0131nda belge revizyonunu, test ko\u015fullar\u0131n\u0131 ve doldurulmam\u0131\u015f alanlar\u0131 belirtin.<\/p>\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Kar\u015f\u0131la\u015ft\u0131rma noktas\u0131<\/th><th>Gerekli kan\u0131tlar<\/th><th>Kabul etmeyin<\/th><\/tr><\/thead><tbody><tr><td>Etiketin anlam\u0131<\/td><td>Nominal 10&#215;38 physical format<\/td><td>Nominal 10&#215;65 physical format<\/td><\/tr><tr><td>Gerilim\/ak\u0131m<\/td><td>Tam model sat\u0131r\u0131n\u0131 oku<\/td><td>Tam model sat\u0131r\u0131n\u0131 oku<\/td><\/tr><tr><td>\u00c7al\u0131\u015fma davran\u0131\u015f\u0131<\/td><td>Tam e\u011fri\/kategori kullan<\/td><td>Tam e\u011fri\/kategori kullan<\/td><\/tr><tr><td>Tutucu<\/td><td>Verify exact 10&#215;38 assembly<\/td><td>Verify exact 10&#215;65 assembly<\/td><\/tr><tr><td>De\u011fi\u015ftirilebilirlik<\/td><td>Belirlenmemi\u015ftir<\/td><td>Belirlenmemi\u015ftir<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n<figure data-spectra-id=\"spectra-cf7f29b0-2946-44ab-b4f5-0bdb6154389e\" class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-015-BODY-02.webp\" alt=\"Sigorta eleman\u0131 ve tutucu belgeleri kan\u0131t haritas\u0131\" class=\"wp-image-1282\" width=\"1400\" height=\"1050\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-015-BODY-02.webp 1400w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-015-BODY-02-600x450.webp 600w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-015-BODY-02-300x225.webp 300w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-015-BODY-02-1024x768.webp 1024w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-015-BODY-02-768x576.webp 768w\" sizes=\"auto, (max-width: 1400px) 100vw, 1400px\" \/><figcaption class=\"wp-element-caption\">E\u015fle\u015ftirmeyi onaylamadan \u00f6nce sigorta eleman\u0131 ve yuva kay\u0131tlar\u0131n\u0131 birlikte kontrol edin.<\/figcaption><\/figure>\n\n\n<p class=\"wp-block-paragraph\">Bir teklif, teknik a\u00e7\u0131dan eksik olsa bile ticari a\u00e7\u0131dan cazip kalabilir. Eksik verileri \u201challetilmesi gereken i\u015f\u201d olarak i\u015faretleyin ve tedarik\u00e7iden ilgili sayfan\u0131n, \u00e7izimin veya bile\u015fen tablosunun tam kopyas\u0131n\u0131 isteyin. Fiyat ve teslim s\u00fcresi, ancak teknik kapsam netle\u015ftirildikten sonra kar\u015f\u0131la\u015ft\u0131r\u0131lmal\u0131d\u0131r. Bu, daha d\u00fc\u015f\u00fck maliyetli ancak daha s\u0131n\u0131rl\u0131 bir teklifin, eksiksiz ve belgelenmi\u015f bir \u00e7\u00f6z\u00fcmle e\u015fde\u011fermi\u015f gibi g\u00f6r\u00fcnmesini engeller.<\/p>\n\n<h2 class=\"wp-block-heading\">Karar \u0130\u015f Ak\u0131\u015f\u0131<\/h2>\n\n<ul class=\"wp-block-list\"><li>Uygulama ve koruma hedefini tan\u0131mlay\u0131n.<\/li><li>Gerilim, ak\u0131m ve ar\u0131za durumlar\u0131n\u0131 kaydedin.<\/li><li>Gerekli sigorta kategorisini do\u011frulay\u0131n.<\/li><li>Tam ve kesin modele dayal\u0131 elektrik kay\u0131tlar\u0131n\u0131 kar\u015f\u0131la\u015ft\u0131r\u0131n.<\/li><li>Tutan\u0131n ve terminallerin tam yerle\u015fimini kontrol edin.<\/li><li>Sipari\u015f vermeden \u00f6nce e\u011frileri, boyutlar\u0131 ve belge revizyonlar\u0131n\u0131 talep edin.<\/li><\/ul>\n\n<p class=\"wp-block-paragraph\">Her a\u015famada, proje girdileri ile tedarik\u00e7inin sundu\u011fu kan\u0131tlar aras\u0131ndaki s\u0131n\u0131r\u0131 koruyun. Proje ekibi, uygulamay\u0131 ve gerekli i\u015flevleri tan\u0131mlar; tedarik\u00e7i ise kesin bir \u00fcr\u00fcn belirler ve ilgili belgeleri sunar. Taraflardan hi\u00e7biri, g\u00f6r\u00fcn\u00fc\u015ften, benzer bir modelden veya ortak bir genel derecelendirme notundan \u00e7\u0131kar\u0131mlarda bulunarak kan\u0131t eksikli\u011fini gidermemelidir.<\/p>\n\n<h2 class=\"wp-block-heading\">Teklif Talebi Haz\u0131rl\u0131k Kontrol Listesi<\/h2>\n\n<p class=\"wp-block-paragraph\">A useful RFQ for 10&#215;38 vs 10&#215;65 fuse should be concise enough to answer but complete enough to prevent silent assumptions. Attach the available project record and identify unknown values as questions. Ask the supplier to answer with an exact orderable code rather than a generic product-family recommendation.<\/p>\n\n<ul class=\"wp-block-list\"><li>Devrenin kullan\u0131m\u0131 ve yeri<\/li><li>Maksimum do\u011fru ak\u0131m gerilimi<\/li><li>Normal ak\u0131m ve ar\u0131za bilgileri<\/li><li>Gerekli sigorta kategorisi<\/li><li>Yaln\u0131zca mekanik k\u0131s\u0131tlamalar s\u00f6z konusu oldu\u011funda tercih edilen format<\/li><li>Mevcut veya \u00f6nerilen sahip kodu<\/li><li>Miktar ve var\u0131\u015f yeri<\/li><\/ul>\n\n<p class=\"wp-block-paragraph\">G\u00fcncel teknik veri sayfas\u0131 s\u00fcr\u00fcm\u00fcn\u00fc talep edin ve herhangi bir sertifikasyon, koordinasyon veya uyumluluk iddias\u0131n\u0131n kapsam\u0131n\u0131 belirleyin. Yan\u0131tta bir alternatif \u00f6neriliyorsa, o alternatif i\u00e7in de ayn\u0131 kan\u0131t setini talep edin. Ticari \u015fartlar\u0131n \u00e7\u00f6z\u00fclmemi\u015f m\u00fchendislik sorunlar\u0131n\u0131 g\u00f6lgelememesi i\u00e7in, teknik girdilerin ard\u0131ndan miktar\u0131 ve var\u0131\u015f yerini kaydedin.<\/p>\n\n<h2 class=\"wp-block-heading\">Sipari\u015fin Serbest B\u0131rak\u0131lmas\u0131ndan \u00d6nceki Durdurma Ko\u015fullar\u0131<\/h2>\n\n<p class=\"wp-block-paragraph\">Yay\u0131n a\u00e7\u0131s\u0131ndan kritik bir girdi bilinmiyorsa, belirtilen model belirsizse veya gerekli bir derecelendirme yaln\u0131zca ba\u015fka bir \u00fcreticinin belgesiyle destekleniyorsa, sipari\u015fi onaylamay\u0131n. Ayr\u0131ca, bir kombinasyon talebinde kesin bile\u015fen kodlar\u0131 eksikse veya bir \u015fema farkl\u0131 \u00fcr\u00fcn ailelerinde yeniden kullan\u0131l\u0131yorsa da i\u015flemi durdurun. Bunlar, editoryal ayr\u0131nt\u0131lar de\u011fil, kan\u0131t eksiklikleridir.<\/p>\n\n<p class=\"wp-block-paragraph\">Nihai onay kayd\u0131nda, se\u00e7ilen \u00f6\u011fenin ne i\u015fe yarad\u0131\u011f\u0131, kapsam\u0131 d\u0131\u015f\u0131nda kalan unsurlar ve karar\u0131 destekleyen belgelerin tam olarak hangileri oldu\u011fu belirtilmelidir. Uygulama, g\u00f6rev, ortam veya \u00f6nerilen modelde de\u011fi\u015fiklik olmas\u0131 durumunda, \u00f6nceki sonucu aynen devralmak yerine ilgili kontrolleri yeniden ba\u015flat\u0131n.<\/p>\n\n<h2 class=\"wp-block-heading\">S\u0131k Sorulan Sorular<\/h2>\n\n<h3 class=\"wp-block-heading\">Does 10&#215;65 automatically mean a higher current rating?<\/h3>\n\n<p class=\"wp-block-paragraph\">Hay\u0131r. Tam model tablolar\u0131n\u0131 kar\u015f\u0131la\u015ft\u0131r\u0131n; fiziksel uzunluk, elektrik alan\u0131nda evrensel bir kural de\u011fildir.<\/p>\n\n<h3 class=\"wp-block-heading\">Ayn\u0131 boyuttaki bir ba\u011flant\u0131 her tutucuya s\u0131\u011fabilir mi?<\/h3>\n\n<p class=\"wp-block-paragraph\">Mekanik uyum yeterli de\u011fildir. Belgelenmi\u015f tutucu\/ba\u011flant\u0131 e\u015fle\u015fmesini ve her iki de\u011ferini de kontrol edin.<\/p>\n\n<h3 class=\"wp-block-heading\">Her iki format da her zaman gPV mi?<\/h3>\n\n<p class=\"wp-block-paragraph\">Hay\u0131r. Kullan\u0131m kategorisi, yaln\u0131zca boyutlara de\u011fil, tam ba\u011flant\u0131ya aittir.<\/p>\n\n<h2 class=\"wp-block-heading\">\u0130lgili RITOKS \u00dcr\u00fcnleri ve K\u0131lavuzlar<\/h2>\n\n<p class=\"wp-block-paragraph\">Bu ba\u011flant\u0131lar\u0131 ayr\u0131 kategori, \u00fcr\u00fcn ve e\u011fitim kay\u0131tlar\u0131 olarak kullan\u0131n. Ba\u011flamsal bir ba\u011flant\u0131, kar\u015f\u0131l\u0131kl\u0131 de\u011fi\u015ftirilebilirlik, uyumluluk veya koordineli bir birle\u015fim iddias\u0131nda bulunmaz.<\/p>\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/ritoks.com\/tr\/product-category\/dc-power-protection\/dc-fuses-fuse-holders\/\">DC Sigorta \u00fcr\u00fcn kategorisi<\/a><\/p>\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/ritoks.com\/tr\/products\/10x38-1000v-dc-gpv-fuse-link-6-32a\/\">10&#215;38 1000V gPV fuse links<\/a><\/p>\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/ritoks.com\/tr\/products\/10x65-1500v-dc-gpv-fuse-link-6-32a\/\">10&#215;65 1500V gPV fuse links<\/a><\/p>\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/ritoks.com\/tr\/dc-fuse-selection-guide\/\">DC sigorta se\u00e7im k\u0131lavuzu<\/a><\/p>\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/ritoks.com\/tr\/what-is-a-gpv-fuse\/\">gPV sigortas\u0131 nedir?<\/a><\/p>\n\n<h2 class=\"wp-block-heading\">Teknik Kaynaklar<\/h2>\n\n<p class=\"wp-block-paragraph\">A\u015fa\u011f\u0131daki g\u00fcvenilir kaynaklar, yaln\u0131zca a\u015fa\u011f\u0131da belirtilen genel kavramlar\u0131 desteklemektedir. Bu kaynaklardaki \u00fcr\u00fcn de\u011ferleri, \u015femalar, kombinasyonlar ve onaylar, RITOKS \u00fcr\u00fcnlerine uygulanmaz.<\/p>\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.mersen.com\/sites\/default\/files\/files_imported_ep\/TT-PVPN3-Photovoltaic-Market-Over-Current-Protection-EN.pdf\" target=\"_blank\" rel=\"noopener\">Mersen, Fotovoltaik Pazar\u0131: A\u015f\u0131r\u0131 Ak\u0131m Korumas\u0131<\/a><\/p>\n\n<p class=\"wp-block-paragraph\">PV sigorta eleman\u0131 uygulama konseptlerini ve format, nominal de\u011ferler ile e\u011frilerin birbiriyle tam olarak uyumlu tutulmas\u0131 gereklili\u011fini destekler. Mersen de\u011ferleri, RITOKS de\u011ferleri de\u011fildir.<\/p>\n\n<h2 class=\"wp-block-heading\">Belirli Bir Modelin \u0130ncelenmesini Talep Et<\/h2>\n\n<p class=\"wp-block-paragraph\">Kaydedilen uygulama gereksinimlerini, belgelerle ilgili kesin sorular\u0131, miktar\u0131 ve teslimat adresini RITOKS ileti\u015fim formu arac\u0131l\u0131\u011f\u0131yla g\u00f6nderin. Bir RFQ, kesin model incelemesi talep eder; bu k\u0131lavuz, kablolama tasar\u0131m\u0131n\u0131, kurulumu veya otomatik ikameyi onaylamaz.<\/p>\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/ritoks.com\/tr\/contact-us\/\">RITOKS ile ileti\u015fime ge\u00e7in<\/a><\/p>","protected":false},"excerpt":{"rendered":"<p>Compare 10&#215;38 and 10&#215;65 DC fuse links by voltage, current, fuse class, fault duty and documented holder compatibility.<\/p>","protected":false},"author":1,"featured_media":1280,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"no-sidebar","site-content-layout":"page-builder","ast-site-content-layout":"full-width-container","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"disabled","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"disabled","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ritoks_resource_detail_renderer":"viox","ritoks_resource_product_cat_term_id":0,"footnotes":""},"categories":[64],"tags":[],"class_list":["post-1302","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-circuit-protection"],"acf":[],"spectra_blocks_featured_image_url":{"thumbnail":{"url":"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-015-HERO-01-150x150.webp","width":150,"height":150},"medium":{"url":"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-015-HERO-01-300x169.webp","width":300,"height":169},"medium_large":{"url":"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-015-HERO-01-768x432.webp","width":768,"height":432},"large":{"url":"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-015-HERO-01-1024x576.webp","width":1024,"height":576},"full":{"url":"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-015-HERO-01.webp","width":1600,"height":900}},"spectra_blocks_author_info":{"display_name":"RITOKS","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/6d7d0fc73468198f994ab13ef6eb6558c53b6ed1ad86364d5165efe8bdf8eb4a?s=96&d=mm&r=g","author_link":"https:\/\/ritoks.com\/tr\/author\/dazzlingwqbgmail-com\/","description":""},"_links":{"self":[{"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/posts\/1302","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/comments?post=1302"}],"version-history":[{"count":1,"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/posts\/1302\/revisions"}],"predecessor-version":[{"id":1310,"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/posts\/1302\/revisions\/1310"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/media\/1280"}],"wp:attachment":[{"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/media?parent=1302"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/categories?post=1302"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/tags?post=1302"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}