{"id":1304,"date":"2026-09-21T15:38:47","date_gmt":"2026-09-21T15:38:47","guid":{"rendered":"https:\/\/ritoks.com\/?p=1304"},"modified":"2026-09-21T15:38:47","modified_gmt":"2026-09-21T15:38:47","slug":"ac-3-vs-ac-4-contactor-utilization-categories","status":"publish","type":"post","link":"https:\/\/ritoks.com\/tr\/ac-3-vs-ac-4-contactor-utilization-categories\/","title":{"rendered":"AC-3 ve AC-4 Kontakt\u00f6r Kullan\u0131m Kategorileri: Do\u011frulama K\u0131lavuzu"},"content":{"rendered":"<p class=\"wp-block-paragraph\">AC-3 ve AC-4, farkl\u0131 motor devre kesme g\u00f6revlerini tan\u0131mlayan kullan\u0131m kategorileridir. Bunlar birbirinin yerine kullan\u0131labilen ak\u0131m s\u0131n\u0131flar\u0131 de\u011fildir. Al\u0131c\u0131, motorun nas\u0131l \u00e7al\u0131\u015ft\u0131r\u0131l\u0131p durduruldu\u011funu a\u00e7\u0131klamal\u0131 ve ard\u0131ndan o g\u00f6rev i\u00e7in kontakt\u00f6r\u00fcn tam de\u011ferlerini ve \u00e7al\u0131\u015fma s\u0131n\u0131rlar\u0131n\u0131 kontrol etmelidir.<\/p>\n\n<p class=\"wp-block-paragraph\">Bu makale, AC-3 ile AC-4 y\u00fck s\u0131n\u0131flar\u0131 aras\u0131ndaki fark\u0131 ele almaktad\u0131r. Genel kontakt\u00f6r se\u00e7im k\u0131lavuzunun bir kopyas\u0131 de\u011fildir ve her ZS3TF modelinin ayn\u0131 AC-4 s\u0131n\u0131f\u0131na veya dayan\u0131kl\u0131l\u0131\u011fa sahip oldu\u011funu iddia etmemektedir.<\/p>\n\n\n<figure data-spectra-id=\"spectra-95ff9363-ebef-4475-888a-a73a3bb55b43\" class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-033-HERO-01.webp\" alt=\"AC-3 ve AC-4 kontakt\u00f6rlerinin \u00e7al\u0131\u015fma y\u00fck\u00fc kar\u015f\u0131la\u015ft\u0131rmas\u0131\" class=\"wp-image-1286\" width=\"1600\" height=\"900\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-033-HERO-01.webp 1600w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-033-HERO-01-600x338.webp 600w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-033-HERO-01-300x169.webp 300w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-033-HERO-01-1024x576.webp 1024w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-033-HERO-01-768x432.webp 768w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-033-HERO-01-1536x864.webp 1536w\" sizes=\"auto, (max-width: 1600px) 100vw, 1600px\" \/><\/figure>\n\n\n<h2 class=\"wp-block-heading\">Sat\u0131n Alma Karar\u0131: \u00d6zet<\/h2>\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Karar girdisi<\/th><th>Al\u0131c\u0131 bunu teyit etmelidir<\/th><th>Gerekli kan\u0131tlar<\/th><\/tr><\/thead><tbody><tr><td>Motor\/y\u00fck<\/td><td>Motor tipi ve teknik etiket verileri<\/td><td>Kategorinin tam olarak uygulanabilirli\u011fi<\/td><\/tr><tr><td>G\u00f6rev s\u00fcresi<\/td><td>Normal durma, geri gitme, t\u0131kanma veya yava\u015f ilerleme<\/td><td>AC-3 veya AC-4 tablo sat\u0131r\u0131<\/td><\/tr><tr><td>Mevcut<\/td><td>S\u00f6z konusu g\u00f6rev kapsam\u0131nda \u00e7al\u0131\u015f\u0131lan ak\u0131m<\/td><td>Gerilim\/kategori i\u00e7in kesin IE derecesi<\/td><\/tr><tr><td>Frekans<\/td><td>Saatteki ba\u015flatma, durdurma ve i\u015flem say\u0131s\u0131<\/td><td>Belgelenmi\u015f \u00e7al\u0131\u015fma frekans\u0131 s\u0131n\u0131rlar\u0131<\/td><\/tr><tr><td>Ya\u015fam ko\u015fulu<\/td><td>Beklenen mekanik ve elektriksel i\u015flemler<\/td><td>Kesin dayan\u0131kl\u0131l\u0131k verileri<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n<figure data-spectra-id=\"spectra-a8faf690-7f53-4266-9c29-6deda431abbd\" class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-033-BODY-01.webp\" alt=\"AC-3 ve AC-4 \u00e7al\u0131\u015fma g\u00f6rev dizisi kar\u015f\u0131la\u015ft\u0131rmas\u0131\" class=\"wp-image-1287\" width=\"1400\" height=\"1050\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-033-BODY-01.webp 1400w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-033-BODY-01-600x450.webp 600w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-033-BODY-01-300x225.webp 300w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-033-BODY-01-1024x768.webp 1024w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-033-BODY-01-768x576.webp 768w\" sizes=\"auto, (max-width: 1400px) 100vw, 1400px\" \/><figcaption class=\"wp-element-caption\">Normal \u00e7al\u0131\u015ft\u0131rma ve \u00e7al\u0131\u015fma ko\u015fullar\u0131n\u0131, yava\u015f ilerleme, t\u0131kanma ve geri d\u00f6n\u00fc\u015f ko\u015fullar\u0131yla kar\u015f\u0131la\u015ft\u0131r\u0131n.<\/figcaption><\/figure>\n\n\n<h2 class=\"wp-block-heading\">Kullan\u0131m Kategorisi G\u00f6revi Tan\u0131mlar<\/h2>\n\n<p class=\"wp-block-paragraph\">Schneider Electric, AC-3 kategorisini, sincap kafesli motorlar\u0131n \u00e7al\u0131\u015ft\u0131r\u0131lmas\u0131 ve normal \u00e7al\u0131\u015fma s\u0131ras\u0131nda devre d\u0131\u015f\u0131 b\u0131rak\u0131lmas\u0131 i\u00e7in tan\u0131mlamaktad\u0131r. AC-4 ise t\u0131kanma ve yava\u015f ilerleme gibi daha zorlu \u00e7al\u0131\u015fma ko\u015fullar\u0131n\u0131 kapsamaktad\u0131r. Bu kategori, okuyucuya hangi ba\u011flant\u0131 ve kesme ko\u015fullar\u0131n\u0131n de\u011ferlendirildi\u011fini belirtir; genel bir kalite derecesi de\u011fildir.<\/p>\n\n<p class=\"wp-block-paragraph\">Normalde bir motoru \u00e7al\u0131\u015ft\u0131ran ve \u00e7al\u0131\u015fmaya ba\u015flad\u0131ktan sonra durduran bir proje, s\u0131rf daha dayan\u0131kl\u0131 bir \u00fcr\u00fcn talep etmek amac\u0131yla AC-4 olarak tan\u0131mlanmamal\u0131d\u0131r. Buna kar\u015f\u0131l\u0131k, motoru tekrar tekrar yava\u015f\u00e7a hareket ettiren veya t\u0131kayan bir uygulama i\u00e7in AC-3 ak\u0131m s\u00fctunundan fiyat teklifi verilmemelidir. Ger\u00e7ek \u00e7al\u0131\u015fma s\u0131ras\u0131n\u0131 a\u00e7\u0131klay\u0131n.<\/p>\n\n<h2 class=\"wp-block-heading\">S\u00fctunlar Aras\u0131nda Ak\u0131m De\u011ferlerini Aktarmay\u0131n<\/h2>\n\n<p class=\"wp-block-paragraph\">Bir kontakt\u00f6r, kesme g\u00f6revinin farkl\u0131 olmas\u0131 nedeniyle AC-3 ve AC-4 alt\u0131nda farkl\u0131 \u00e7al\u0131\u015fma ak\u0131m\u0131 de\u011ferlerine sahip olabilir. Tam model, gerilim ve kullan\u0131m kategorisi sat\u0131rlar\u0131n\u0131 kar\u015f\u0131la\u015ft\u0131r\u0131n. \u00dcr\u00fcn ailesinin maksimum de\u011feri ve model ad\u0131, bu tablonun yerini almaz.<\/p>\n\n<p class=\"wp-block-paragraph\">ZS3TF kaynak kayd\u0131nda, 380 V\u2019da belgelenmi\u015f modeller i\u00e7in ayr\u0131 AC-3 ve AC-4 de\u011ferleri yer almaktad\u0131r. Bu de\u011ferler modele \u00f6zeldir. Al\u0131c\u0131, eksik bir AC-4 de\u011ferini yak\u0131n bir modelden \u00e7\u0131karsamamal\u0131 veya kan\u0131t olmaks\u0131z\u0131n 380 V\u2019luk bir de\u011feri ba\u015fka bir gerilime uygulamamal\u0131d\u0131r.<\/p>\n\n<h2 class=\"wp-block-heading\">S\u0131kl\u0131k ve Dayan\u0131kl\u0131l\u0131k \u00d6nemlidir<\/h2>\n\n<p class=\"wp-block-paragraph\">Tek bir \u00e7al\u0131\u015fma g\u00f6revini yerine getirebilen bir kontakt\u00f6r, istenen \u00e7al\u0131\u015fma say\u0131s\u0131 i\u00e7in otomatik olarak uygun de\u011fildir. \u00d6ng\u00f6r\u00fclen kategori kapsam\u0131nda belgelenmi\u015f anahtarlama s\u0131kl\u0131\u011f\u0131 ve elektriksel dayan\u0131kl\u0131l\u0131k de\u011ferlerini talep edin. Teklif talebine saat ba\u015f\u0131na beklenen \u00e7al\u0131\u015fma say\u0131s\u0131 ve hizmet modelini de ekleyin.<\/p>\n\n<p class=\"wp-block-paragraph\">Mekanik dayan\u0131kl\u0131l\u0131\u011f\u0131 elektriksel dayan\u0131kl\u0131l\u0131ktan ay\u0131r\u0131n. Mekanik i\u015flemler, belirtilen motor y\u00fck\u00fcnde anahtarlama yaparken kontak \u00f6mr\u00fcn\u00fc kan\u0131tlamaz. Bir kaynakta bir model i\u00e7in de\u011fer belirtilmemi\u015fse, bu de\u011feri bilinmeyen olarak b\u0131rak\u0131n ve ba\u015fka bir modelin de\u011ferini aktarmak yerine \u00fcreticiye dan\u0131\u015f\u0131n.<\/p>\n\n<h2 class=\"wp-block-heading\">Kar\u015f\u0131la\u015ft\u0131r\u0131labilir Bir Teklif Haz\u0131rlay\u0131n<\/h2>\n\n<p class=\"wp-block-paragraph\">Her tedarik\u00e7iye ayn\u0131 motor gerilimi, ak\u0131m\u0131, \u00e7al\u0131\u015ft\u0131rma\/durdurma s\u0131ras\u0131, ters y\u00f6n veya kademeli hareket gereksinimi, saat ba\u015f\u0131na \u00e7al\u0131\u015fma say\u0131s\u0131, bobin beslemesi ve yard\u0131mc\u0131 kontak ihtiya\u00e7lar\u0131n\u0131 belirtin. Kesin kontakt\u00f6r kodunu ve kategoriye \u00f6zg\u00fc tabloyu talep edin.<\/p>\n\n<p class=\"wp-block-paragraph\">Devreye alma s\u0131ras\u0131nda \u00e7al\u0131\u015fma ko\u015fullar\u0131nda bir de\u011fi\u015fiklik olursa, kontakt\u00f6r se\u00e7imini yeniden g\u00f6zden ge\u00e7irin. Daha y\u00fcksek motor ak\u0131m\u0131, daha s\u0131k \u00e7al\u0131\u015ft\u0131rma veya normal durdurma y\u00f6nteminden t\u0131kanma y\u00f6ntemine ge\u00e7i\u015f, g\u00f6vde ve terminallerde herhangi bir de\u011fi\u015fiklik g\u00f6r\u00fcnmese bile ilgili nominal de\u011ferleri de\u011fi\u015ftirebilir.<\/p>\n\n<h2 class=\"wp-block-heading\">Onaydan \u00d6nce Bir Kan\u0131t Dosyas\u0131 Haz\u0131rlay\u0131n<\/h2>\n\n<p class=\"wp-block-paragraph\">\u00d6nerilen AC kontakt\u00f6r sipari\u015f kodu i\u00e7in bir inceleme tablosu olu\u015fturun. Uygulama girdilerini sol s\u00fctuna, tedarik\u00e7iye ait kan\u0131tlar\u0131 ise sa\u011f s\u00fctuna yaz\u0131n. En az\u0131ndan motor\/y\u00fck, \u00e7al\u0131\u015fma ko\u015fulu, ak\u0131m ve frekans ile \u00f6m\u00fcr gereksinimi bilgilerini kay\u0131t alt\u0131nda tutun. Bu sayede hangi bilgilerin projeden, hangi bilgilerin ise \u00fcreticiden geldi\u011fi net bir \u015fekilde anla\u015f\u0131l\u0131r.<\/p>\n\n<p class=\"wp-block-paragraph\">Kararda kullan\u0131lan veri sayfalar\u0131n\u0131n, \u00e7izimlerin ve tablolar\u0131n tam kopyalar\u0131n\u0131 ekleyin. Bunlar\u0131n revizyon veya eri\u015fim tarihlerini kaydedin ve belirtilen modele ait sat\u0131r\u0131 vurgulay\u0131n. Bir sat\u0131\u015f e-postas\u0131 kapsam\u0131 netle\u015ftirebilir; ancak karar, bir derecelendirme, ba\u011flant\u0131, devre kesme \u00f6zelli\u011fi, termal s\u0131n\u0131r veya test edilmi\u015f bir kombinasyona ba\u011fl\u0131 oldu\u011funda, teknik belgenin yerini sessizce almamal\u0131d\u0131r.<\/p>\n\n<p class=\"wp-block-paragraph\">Her bir ba\u011flant\u0131l\u0131 de\u011ferin ayn\u0131 sipari\u015f edilebilir konfig\u00fcrasyonu tan\u0131mlad\u0131\u011f\u0131n\u0131 kontrol edin. Benzer model isimleri genellikle ayn\u0131 g\u00f6vdeyi payla\u015f\u0131rken, kontrol beslemesi, ak\u0131m aral\u0131\u011f\u0131, kutuplar, terminaller, aksesuarlar veya \u00e7evresel s\u0131n\u0131rlar a\u00e7\u0131s\u0131ndan farkl\u0131l\u0131k g\u00f6sterebilir. Bir belge birka\u00e7 varyant\u0131 kaps\u0131yorsa, sayfadaki en geni\u015f aral\u0131\u011f\u0131 her varyant\u0131n kapasitesi olarak kabul etmek yerine, se\u00e7ilen sat\u0131r\u0131 i\u015faretleyin.<\/p>\n\n<h2 class=\"wp-block-heading\">Tedarik S\u00fcrecinde Yap\u0131lan Kontrol De\u011fi\u015fiklikleri<\/h2>\n\n<p class=\"wp-block-paragraph\">Tedarik\u00e7iler tekliflerini haz\u0131rlarken ba\u015fvuru kayd\u0131n\u0131 dondurulmu\u015f halde tutun. Gerilim, y\u00fck, \u00e7al\u0131\u015fma ko\u015fulu, ar\u0131za seviyesi, muhafaza veya \u00e7al\u0131\u015fma y\u00f6ntemi gibi bilgilerde de\u011fi\u015fiklik olmas\u0131 durumunda, g\u00fcncellenmi\u015f bir kay\u0131t yay\u0131nlay\u0131n ve her tedarik\u00e7iden aday \u00fcr\u00fcn\u00fc yeniden onaylamas\u0131n\u0131 isteyin. Aksi takdirde, e-posta konusu ve \u00fcr\u00fcn grubu de\u011fi\u015fmemi\u015f olsa bile, sat\u0131n alma birimi farkl\u0131 gereksinimler i\u00e7in haz\u0131rlanm\u0131\u015f teklifleri kar\u015f\u0131la\u015ft\u0131rabilir.<\/p>\n\n<p class=\"wp-block-paragraph\">Ayn\u0131 kural\u0131 ikame \u00fcr\u00fcnler i\u00e7in de uygulay\u0131n. Fiyat veya temin edilebilirlik nedeniyle \u00f6nerilen bir ikame \u00fcr\u00fcn, kendine ait sipari\u015f kodu ve destekleyici belgelerle birlikte teknik inceleme a\u015famas\u0131na geri g\u00f6nderilir. Yaln\u0131zca nominal ak\u0131m, \u00fcr\u00fcn \u015fekli veya montaj y\u00f6nteminin orijinal adaya benzemesi nedeniyle bunu onaylamay\u0131n. \u0130kame i\u015flemi, ancak gerekli i\u015flevler ve ko\u015fullar yeniden kontrol edildi\u011finde tamamlanm\u0131\u015f say\u0131l\u0131r.<\/p>\n\n<h2 class=\"wp-block-heading\">\u0130hale S\u00fcrecinde S\u0131k G\u00f6r\u00fclen Hatalar<\/h2>\n\n<ul class=\"wp-block-list\"><li>Uygulama ba\u011flam\u0131n\u0131 tan\u0131mlamadan, tek bir nominal de\u011fer \u00fczerinden AC kontakt\u00f6r se\u00e7imi.<\/li><li>Kapsam\u0131n\u0131 teyit etmeden kom\u015fu bir modele ait bir \u015fema, e\u011fri veya aksesuar tablosunu kullanmak.<\/li><li>Bir \u00fcr\u00fcn kategorisi sayfas\u0131n\u0131 veya pazarlama g\u00f6rselini, tam model kan\u0131t\u0131 olarak de\u011ferlendirmek.<\/li><li>Sadece cihazdan olu\u015fan bir teklif ile montajl\u0131 veya aksesuarlar dahil bir teklifi kar\u015f\u0131la\u015ft\u0131rma.<\/li><li>Ticari teklifin revize edilmesi s\u0131ras\u0131nda, hen\u00fcz \u00e7\u00f6z\u00fclmemi\u015f bir teknik konunun ortadan kalkmas\u0131na izin vermek.<\/li><\/ul>\n\n<p class=\"wp-block-paragraph\">Ticari kar\u015f\u0131la\u015ft\u0131rma yapmadan \u00f6nce bu hatalar\u0131 giderin. Teknik inceleme uzman\u0131, haf\u0131zas\u0131na g\u00fcvenmek zorunda kalmadan kabul edilen her bir beyan\u0131 proje kayd\u0131na veya ilgili belgeye kadar izleyebilmelidir. B\u00f6ylelikle, sat\u0131n alma birimi, sipari\u015f verildikten sonra se\u00e7im s\u00fcrecini yeniden ba\u015flatmak yerine, fiyat, miktar, var\u0131\u015f yeri ve teslim s\u00fcresini sabit bir teknik referans noktas\u0131 ile kar\u015f\u0131la\u015ft\u0131rabilir.<\/p>\n\n<h2 class=\"wp-block-heading\">Tedarik\u00e7i Tekliflerini Kar\u015f\u0131la\u015ft\u0131rma Y\u00f6ntemleri<\/h2>\n\n<p class=\"wp-block-paragraph\">Her bir AC kontakt\u00f6r teklifini, sabitlenmi\u015f bir uygulama kayd\u0131yla kar\u015f\u0131la\u015ft\u0131r\u0131n. Birka\u00e7 varyanttan en iyi rakamlar\u0131 birle\u015ftirmeyin veya teklif edilen sipari\u015f kodunun de\u011feri olarak \u00fcr\u00fcn ailesinin en y\u00fcksek de\u011ferini kabul etmeyin. Sat\u0131n alma ekibinin iki teklifin ger\u00e7ekten e\u015fde\u011fer olup olmad\u0131\u011f\u0131n\u0131 g\u00f6rebilmesi i\u00e7in, her bir de\u011ferin yan\u0131nda belge revizyonunu, test ko\u015fullar\u0131n\u0131 ve \u00e7\u00f6z\u00fclmemi\u015f alanlar\u0131 belirtin.<\/p>\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Kar\u015f\u0131la\u015ft\u0131rma noktas\u0131<\/th><th>Gerekli kan\u0131tlar<\/th><th>Kabul etmeyin<\/th><\/tr><\/thead><tbody><tr><td>Motorun \u00e7al\u0131\u015fmas\u0131<\/td><td>AC-3: \u00c7al\u0131\u015fma s\u0131ras\u0131nda ba\u015flatma ve kapatma<\/td><td>AC-4: \u00c7al\u0131\u015ft\u0131rma, t\u0131kanma ve yava\u015f ilerleme g\u00f6revleri<\/td><\/tr><tr><td>Derecelendirme kayna\u011f\u0131<\/td><td>Tam AC-3 sat\u0131r\u0131<\/td><td>Exact AC-4 serisi<\/td><\/tr><tr><td>\u00c7al\u0131\u015fma frekans\u0131<\/td><td>Tam model ve kullan\u0131m amac\u0131n\u0131 do\u011frulay\u0131n<\/td><td>Tam model ve kullan\u0131m amac\u0131n\u0131 do\u011frulay\u0131n<\/td><\/tr><tr><td>Dayan\u0131kl\u0131l\u0131k<\/td><td>AC-3 \u015fartlar\u0131nda elektriksel \u00f6m\u00fcr<\/td><td>AC-4 \u015fartlar\u0131 alt\u0131nda elektriksel \u00f6m\u00fcr<\/td><\/tr><tr><td>De\u011fi\u015ftirme<\/td><td>Otomatik aktar\u0131m yok<\/td><td>Otomatik aktar\u0131m yok<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n<figure data-spectra-id=\"spectra-32dc0bc0-a88c-493d-886b-ed8a7838eff2\" class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-033-BODY-02.webp\" alt=\"Kontakt\u00f6r kullan\u0131m kategorisi kan\u0131t kontrol listesi\" class=\"wp-image-1288\" width=\"1400\" height=\"1050\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-033-BODY-02.webp 1400w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-033-BODY-02-600x450.webp 600w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-033-BODY-02-300x225.webp 300w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-033-BODY-02-1024x768.webp 1024w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-033-BODY-02-768x576.webp 768w\" sizes=\"auto, (max-width: 1400px) 100vw, 1400px\" \/><figcaption class=\"wp-element-caption\">Y\u00fck t\u00fcr\u00fcn\u00fc, \u00e7al\u0131\u015fma \u015feklini, anahtarlama frekans\u0131n\u0131 ve \u00fcretici verilerini do\u011frulay\u0131n.<\/figcaption><\/figure>\n\n\n<p class=\"wp-block-paragraph\">Bir teklif, teknik a\u00e7\u0131dan eksik olsa bile ticari a\u00e7\u0131dan cazip kalabilir. Eksik verileri \u201challetilmesi gereken i\u015f\u201d olarak i\u015faretleyin ve tedarik\u00e7iden ilgili sayfan\u0131n, \u00e7izimin veya bile\u015fen tablosunun tam kopyas\u0131n\u0131 isteyin. Fiyat ve teslim s\u00fcresi, ancak teknik kapsam netle\u015ftirildikten sonra kar\u015f\u0131la\u015ft\u0131r\u0131lmal\u0131d\u0131r. Bu, daha d\u00fc\u015f\u00fck maliyetli ancak daha s\u0131n\u0131rl\u0131 bir teklifin, eksiksiz ve belgelenmi\u015f bir \u00e7\u00f6z\u00fcmle e\u015fde\u011fermi\u015f gibi g\u00f6r\u00fcnmesini engeller.<\/p>\n\n<h2 class=\"wp-block-heading\">Karar \u0130\u015f Ak\u0131\u015f\u0131<\/h2>\n\n<ul class=\"wp-block-list\"><li>Motorun ger\u00e7ek \u00e7al\u0131\u015fma s\u0131ras\u0131n\u0131 a\u00e7\u0131klay\u0131n.<\/li><li>Normal \u00e7al\u0131\u015fma durmas\u0131, yava\u015f ilerleme, t\u0131kanma veya geri d\u00f6n\u00fc\u015f durumlar\u0131ndan hangisinin meydana geldi\u011fini belirleyin.<\/li><li>Gerilimi, motor ak\u0131m\u0131n\u0131 ve saat ba\u015f\u0131na \u00e7al\u0131\u015fma say\u0131s\u0131n\u0131 kaydedin.<\/li><li>Belirli model i\u00e7in kategoriye \u00f6zg\u00fc ak\u0131m ve dayan\u0131kl\u0131l\u0131k verilerini isteyin.<\/li><li>Bobin ve yard\u0131mc\u0131 bile\u015fenlerin gereksinimlerini ayr\u0131 ayr\u0131 teyit edin.<\/li><li>G\u00f6rev veya s\u0131kl\u0131k de\u011fi\u015firse se\u00e7imi yeniden kontrol edin.<\/li><\/ul>\n\n<p class=\"wp-block-paragraph\">Her a\u015famada, proje girdileri ile tedarik\u00e7inin sundu\u011fu kan\u0131tlar aras\u0131ndaki s\u0131n\u0131r\u0131 koruyun. Proje ekibi, uygulamay\u0131 ve gerekli i\u015flevleri tan\u0131mlar; tedarik\u00e7i ise kesin bir \u00fcr\u00fcn belirler ve ilgili belgeleri sunar. Taraflardan hi\u00e7biri, g\u00f6r\u00fcn\u00fc\u015ften, benzer bir modelden veya ortak bir genel derecelendirme notundan \u00e7\u0131kar\u0131mlarda bulunarak kan\u0131t eksikli\u011fini gidermemelidir.<\/p>\n\n<h2 class=\"wp-block-heading\">Teklif Talebi Haz\u0131rl\u0131k Kontrol Listesi<\/h2>\n\n<p class=\"wp-block-paragraph\">AC3 ile AC4 kontakt\u00f6rleri kar\u015f\u0131la\u015ft\u0131rmas\u0131na y\u00f6nelik faydal\u0131 bir teklif talebi, yan\u0131tlanmas\u0131 kolay olacak kadar \u00f6zl\u00fc, ancak varsay\u0131mlara yer b\u0131rakmayacak kadar kapsaml\u0131 olmal\u0131d\u0131r. Elinizdeki proje belgelerini ekleyin ve bilinmeyen de\u011ferleri soru olarak belirtin. Tedarik\u00e7iden, genel bir \u00fcr\u00fcn ailesi \u00f6nerisi yerine, sipari\u015f verilebilecek kesin bir kodla yan\u0131t vermesini isteyin.<\/p>\n\n<ul class=\"wp-block-list\"><li>Motor tipi, gerilim ve tip plakas\u0131 ak\u0131m\u0131<\/li><li>Ba\u015flatma\/durdurma ve geri gitme\/yava\u015f ilerleme s\u0131ras\u0131<\/li><li>Saat ba\u015f\u0131na beklenen i\u015flem say\u0131s\u0131<\/li><li>Zorunlu kullan\u0131m kategorisi<\/li><li>Kategoriye \u00f6zg\u00fc kesin ak\u0131m ve dayan\u0131kl\u0131l\u0131k tablosu<\/li><li>Bobin ve yard\u0131mc\u0131 kontaklar<\/li><li>Miktar ve var\u0131\u015f yeri<\/li><\/ul>\n\n<p class=\"wp-block-paragraph\">G\u00fcncel teknik veri sayfas\u0131 s\u00fcr\u00fcm\u00fcn\u00fc talep edin ve herhangi bir sertifikasyon, koordinasyon veya uyumluluk iddias\u0131n\u0131n kapsam\u0131n\u0131 belirleyin. Yan\u0131tta bir alternatif \u00f6neriliyorsa, o alternatif i\u00e7in de ayn\u0131 kan\u0131t setini talep edin. Ticari \u015fartlar\u0131n \u00e7\u00f6z\u00fclmemi\u015f m\u00fchendislik sorunlar\u0131n\u0131 g\u00f6lgelememesi i\u00e7in, teknik girdilerin ard\u0131ndan miktar\u0131 ve var\u0131\u015f yerini kaydedin.<\/p>\n\n<h2 class=\"wp-block-heading\">Sipari\u015fin Serbest B\u0131rak\u0131lmas\u0131ndan \u00d6nceki Durdurma Ko\u015fullar\u0131<\/h2>\n\n<p class=\"wp-block-paragraph\">Yay\u0131n a\u00e7\u0131s\u0131ndan kritik bir girdi bilinmiyorsa, belirtilen model belirsizse veya gerekli bir derecelendirme yaln\u0131zca ba\u015fka bir \u00fcreticinin belgesiyle destekleniyorsa, sipari\u015fi onaylamay\u0131n. Ayr\u0131ca, bir kombinasyon talebinde kesin bile\u015fen kodlar\u0131 eksikse veya bir \u015fema farkl\u0131 \u00fcr\u00fcn ailelerinde yeniden kullan\u0131l\u0131yorsa da i\u015flemi durdurun. Bunlar, editoryal ayr\u0131nt\u0131lar de\u011fil, kan\u0131t eksiklikleridir.<\/p>\n\n<p class=\"wp-block-paragraph\">Nihai onay kayd\u0131nda, se\u00e7ilen \u00f6\u011fenin ne i\u015fe yarad\u0131\u011f\u0131, kapsam\u0131 d\u0131\u015f\u0131nda kalan unsurlar ve karar\u0131 destekleyen belgelerin tam olarak hangileri oldu\u011fu belirtilmelidir. Uygulama, g\u00f6rev, ortam veya \u00f6nerilen modelde de\u011fi\u015fiklik olmas\u0131 durumunda, \u00f6nceki sonucu aynen devralmak yerine ilgili kontrolleri yeniden ba\u015flat\u0131n.<\/p>\n\n<h2 class=\"wp-block-heading\">S\u0131k Sorulan Sorular<\/h2>\n\n<h3 class=\"wp-block-heading\">AC-4, AC-3\u2019ten sadece daha y\u00fcksek bir derecelendirme mi?<\/h3>\n\n<p class=\"wp-block-paragraph\">Hay\u0131r. Bu, genel bir kalite seviyesini de\u011fil, farkl\u0131 ve genellikle daha a\u011f\u0131r bir \u00e7al\u0131\u015fma y\u00fck\u00fcml\u00fcl\u00fc\u011f\u00fcn\u00fc ifade eder.<\/p>\n\n<h3 class=\"wp-block-heading\">\u0130nching i\u015flemi i\u00e7in AC-3 amper de\u011ferini kullanabilir miyim?<\/h3>\n\n<p class=\"wp-block-paragraph\">\u00dcreticiden kesin bir kan\u0131t olmadan olmaz. Yava\u015f ilerleme, AC-4 g\u00f6rev tan\u0131m\u0131na dahildir.<\/p>\n\n<h3 class=\"wp-block-heading\">Model ad\u0131, AC-4 s\u0131n\u0131fland\u0131rmas\u0131n\u0131 g\u00f6steriyor mu?<\/h3>\n\n<p class=\"wp-block-paragraph\">Hay\u0131r. Sipari\u015f edilebilen o modele ait kategoriyi ve voltaj sat\u0131r\u0131n\u0131 dikkatlice okuyun.<\/p>\n\n<h2 class=\"wp-block-heading\">\u0130lgili RITOKS \u00dcr\u00fcnleri ve K\u0131lavuzlar<\/h2>\n\n<p class=\"wp-block-paragraph\">Bu ba\u011flant\u0131lar\u0131 ayr\u0131 kategori, \u00fcr\u00fcn ve e\u011fitim kay\u0131tlar\u0131 olarak kullan\u0131n. Ba\u011flamsal bir ba\u011flant\u0131, kar\u015f\u0131l\u0131kl\u0131 de\u011fi\u015ftirilebilirlik, uyumluluk veya koordineli bir birle\u015fim iddias\u0131nda bulunmaz.<\/p>\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/ritoks.com\/tr\/product-category\/industrial-power-switching\/ac-contactors\/\">AC Kontakt\u00f6r\u00fc \u00fcr\u00fcn kategorisi<\/a><\/p>\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/ritoks.com\/tr\/products\/zs3tf-series-industrial-ac-contactors-9a-400a\/\">ZS3TF AC kontakt\u00f6rleri<\/a><\/p>\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/ritoks.com\/tr\/ac-contactor-selection-guide\/\">AC kontakt\u00f6r se\u00e7im k\u0131lavuzu<\/a><\/p>\n\n<h2 class=\"wp-block-heading\">Teknik Kaynaklar<\/h2>\n\n<p class=\"wp-block-paragraph\">A\u015fa\u011f\u0131daki g\u00fcvenilir kaynaklar, yaln\u0131zca a\u015fa\u011f\u0131da belirtilen genel kavramlar\u0131 desteklemektedir. Bu kaynaklardaki \u00fcr\u00fcn de\u011ferleri, \u015femalar, kombinasyonlar ve onaylar, RITOKS \u00fcr\u00fcnlerine uygulanmaz.<\/p>\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/productinfo.se.com\/tesysgigainstallationguide\/tesys-giga-series-giga-contactors-and-giga-thermal-overload-relays-installation-guide\/English\/TeSys%E2%84%A2%20Giga%20Series%20Giga%20Contactors%20and%20Giga%20Thermal%20Overload%20Relays%20Installation%20Guide_0000447511.xml\/%24\/PanGu_LoadsCPT_0000507717\" target=\"_blank\" rel=\"noopener\">Schneider Electric, TeSys Giga Kullan\u0131m Kategorileri<\/a><\/p>\n\n<p class=\"wp-block-paragraph\">AC-3 ve AC-4 s\u0131n\u0131flar\u0131n\u0131 y\u00fck ve \u00e7al\u0131\u015fma ko\u015fullar\u0131na g\u00f6re tan\u0131mlar. RITOKS modeline g\u00f6re bir derecelendirme belirlemez.<\/p>\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.se.com\/uk\/en\/faqs\/FA142452\/\" target=\"_blank\" rel=\"noopener\">Schneider Electric, Kontakt\u00f6r Se\u00e7imi \u0130\u00e7in Gerekli Bilgiler<\/a><\/p>\n\n<p class=\"wp-block-paragraph\">Ana kontaklar, yard\u0131mc\u0131 kontaklar, bobin ve kapal\u0131 mar\u015f motoru kapsam\u0131n\u0131 birbirinden ay\u0131r\u0131r. Schneider se\u00e7enekleri, RITOKS \u00fcr\u00fcn \u00f6zellikleri de\u011fildir.<\/p>\n\n<h2 class=\"wp-block-heading\">Belirli Bir Modelin \u0130ncelenmesini Talep Et<\/h2>\n\n<p class=\"wp-block-paragraph\">Kaydedilen uygulama gereksinimlerini, belgelerle ilgili kesin sorular\u0131, miktar\u0131 ve teslimat adresini RITOKS ileti\u015fim formu arac\u0131l\u0131\u011f\u0131yla g\u00f6nderin. Bir RFQ, kesin model incelemesi talep eder; bu k\u0131lavuz, kablolama tasar\u0131m\u0131n\u0131, kurulumu veya otomatik ikameyi onaylamaz.<\/p>\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/ritoks.com\/tr\/contact-us\/\">RITOKS ile ileti\u015fime ge\u00e7in<\/a><\/p>","protected":false},"excerpt":{"rendered":"<p>AC-3 ve AC-4 kontakt\u00f6rlerinin \u00e7al\u0131\u015fma ko\u015fullar\u0131n\u0131 anlay\u0131n; ard\u0131ndan uygulama i\u00e7in kesin ak\u0131m, anahtarlama frekans\u0131 ve dayan\u0131kl\u0131l\u0131k verilerini do\u011frulay\u0131n.<\/p>","protected":false},"author":1,"featured_media":1286,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"no-sidebar","site-content-layout":"page-builder","ast-site-content-layout":"full-width-container","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"disabled","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"disabled","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ritoks_resource_detail_renderer":"viox","ritoks_resource_product_cat_term_id":0,"footnotes":""},"categories":[65],"tags":[],"class_list":["post-1304","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-motor-control-protection"],"acf":[],"spectra_blocks_featured_image_url":{"thumbnail":{"url":"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-033-HERO-01-150x150.webp","width":150,"height":150},"medium":{"url":"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-033-HERO-01-300x169.webp","width":300,"height":169},"medium_large":{"url":"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-033-HERO-01-768x432.webp","width":768,"height":432},"large":{"url":"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-033-HERO-01-1024x576.webp","width":1024,"height":576},"full":{"url":"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-033-HERO-01.webp","width":1600,"height":900}},"spectra_blocks_author_info":{"display_name":"RITOKS","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/6d7d0fc73468198f994ab13ef6eb6558c53b6ed1ad86364d5165efe8bdf8eb4a?s=96&d=mm&r=g","author_link":"https:\/\/ritoks.com\/tr\/author\/dazzlingwqbgmail-com\/","description":""},"_links":{"self":[{"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/posts\/1304","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/comments?post=1304"}],"version-history":[{"count":1,"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/posts\/1304\/revisions"}],"predecessor-version":[{"id":1312,"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/posts\/1304\/revisions\/1312"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/media\/1286"}],"wp:attachment":[{"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/media?parent=1304"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/categories?post=1304"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/tags?post=1304"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}