{"id":1305,"date":"2026-09-22T14:17:32","date_gmt":"2026-09-22T14:17:32","guid":{"rendered":"https:\/\/ritoks.com\/?p=1305"},"modified":"2026-09-22T14:17:32","modified_gmt":"2026-09-22T14:17:32","slug":"dc-mcb-rfq-checklist","status":"publish","type":"post","link":"https:\/\/ritoks.com\/tr\/dc-mcb-rfq-checklist\/","title":{"rendered":"OEM ve Panel Al\u0131c\u0131lar\u0131 i\u00e7in DC MCB Teklif Talebi Kontrol Listesi"},"content":{"rendered":"<p class=\"wp-block-paragraph\">Yararl\u0131 bir DC MCB talebi, tedarik\u00e7iye uygun bir \u00fcr\u00fcn aday\u0131n\u0131 belirlemesi i\u00e7in yeterli devre bilgisi ve cevab\u0131n incelenebilir olmas\u0131n\u0131 sa\u011flayacak yeterli belge gereklilikleri sunar. Yaln\u0131zca kutuplar, amper ve miktar bilgilerini i\u00e7eren bir talep ise gerilim, ar\u0131za seviyesi, polarite ve ba\u011flant\u0131 konusunda varsay\u0131mlara yol a\u00e7ar.<\/p>\n\n<p class=\"wp-block-paragraph\">Bu makale, tedarik kontrol listesini i\u00e7ermektedir. Makale, m\u00fchendislik se\u00e7imlerinin yerini almaz, DC MCB se\u00e7im k\u0131lavuzunun tamam\u0131n\u0131 tekrarlamaz veya bir devre i\u00e7in belirli bir kesiciyi onaylamaz.<\/p>\n\n\n<figure data-spectra-id=\"spectra-33fbe0f8-f7fe-40e2-9a52-34e3d19cee0c\" class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-006-HERO-01.webp\" alt=\"DC MCB Teklif Talebi belgelerinin incelenmesi\" class=\"wp-image-1289\" width=\"1600\" height=\"900\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-006-HERO-01.webp 1600w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-006-HERO-01-600x338.webp 600w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-006-HERO-01-300x169.webp 300w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-006-HERO-01-1024x576.webp 1024w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-006-HERO-01-768x432.webp 768w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-006-HERO-01-1536x864.webp 1536w\" sizes=\"auto, (max-width: 1600px) 100vw, 1600px\" \/><\/figure>\n\n\n<h2 class=\"wp-block-heading\">Sat\u0131n Alma Karar\u0131: \u00d6zet<\/h2>\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Karar girdisi<\/th><th>Al\u0131c\u0131 bunu teyit etmelidir<\/th><th>Gerekli kan\u0131tlar<\/th><\/tr><\/thead><tbody><tr><td>Devre kimli\u011fi<\/td><td>Kaynak, y\u00fck ve \u015falterin konumu<\/td><td>Uygulama s\u0131n\u0131r\u0131n\u0131 temizle<\/td><\/tr><tr><td>Gerilim<\/td><td>Normal ve m\u00fcmk\u00fcn olan en y\u00fcksek do\u011fru ak\u0131m gerilimi<\/td><td>Kesin DC nominal de\u011feri ve kutup \u015femas\u0131<\/td><\/tr><tr><td>Mevcut<\/td><td>Normal y\u00fck ve ge\u00e7ici davran\u0131\u015f<\/td><td>Anma ak\u0131m\u0131 ve devre kesme bilgileri<\/td><\/tr><tr><td>Ar\u0131za g\u00f6rev s\u00fcresi<\/td><td>Beklenen k\u0131sa devre ak\u0131m\u0131<\/td><td>Ayn\u0131 ko\u015fullarda k\u0131r\u0131lma kapasitesi<\/td><\/tr><tr><td>Belgeler<\/td><td>Model, \u015fema, veri revizyonu ve gerekli onaylar<\/td><td>Eksiksiz tedarik\u00e7i belge paketi<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n<figure data-spectra-id=\"spectra-04cfba52-890c-48ff-800d-6e069c3bb91e\" class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-006-BODY-01.webp\" alt=\"DC MCB Teklif Talebi Giri\u015f Haritas\u0131\" class=\"wp-image-1290\" width=\"1400\" height=\"1050\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-006-BODY-01.webp 1400w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-006-BODY-01-600x450.webp 600w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-006-BODY-01-300x225.webp 300w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-006-BODY-01-1024x768.webp 1024w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-006-BODY-01-768x576.webp 768w\" sizes=\"auto, (max-width: 1400px) 100vw, 1400px\" \/><figcaption class=\"wp-element-caption\">Sistem gerilimini, y\u00fck ak\u0131m\u0131n\u0131, kutuplar\u0131 ve polariteyi, ar\u0131za seviyesini ve kurulum ko\u015fullar\u0131n\u0131 kaydedin.<\/figcaption><\/figure>\n\n\n<h2 class=\"wp-block-heading\">Cihaz \u00d6n\u00fcndeki Devreyi A\u00e7\u0131klay\u0131n<\/h2>\n\n<p class=\"wp-block-paragraph\">Kesicinin PV, ak\u00fc, kontrol g\u00fcc\u00fc, ara\u00e7, UPS veya tan\u0131mlanm\u0131\u015f ba\u015fka bir DC devresine hizmet edip etmedi\u011fini belirtin. Konumunu ve y\u00fck\u00fcn\u00fc belirleyin. Bu bilgi, MCB\u2019nin se\u00e7imini tek ba\u015f\u0131na belirlemez, ancak tedarik\u00e7inin yanl\u0131\u015f bir gerilim aral\u0131\u011f\u0131 veya g\u00f6rev tan\u0131m\u0131 varsaymas\u0131n\u0131 \u00f6nler.<\/p>\n\n<p class=\"wp-block-paragraph\">Kesicide normal \u00e7al\u0131\u015fma gerilimini ve m\u00fcmk\u00fcn olan en y\u00fcksek gerilimi kaydedin. A\u00e7\u0131k devre veya \u015farj gerilimini art\u0131rabilecek kaynak ko\u015fullar\u0131n\u0131 da dahil edin. Bu rakam\u0131n tam olarak hangi sistem ko\u015fulunu temsil etti\u011fini a\u00e7\u0131klamadan, genel bir 500 V veya 1000 V kesici talep etmeyin.<\/p>\n\n<h2 class=\"wp-block-heading\">Y\u00fck Ak\u0131m\u0131n\u0131 Ar\u0131za Ak\u0131m\u0131ndan Ay\u0131rma<\/h2>\n\n<p class=\"wp-block-paragraph\">S\u00fcrekli y\u00fck ak\u0131m\u0131 ve ilgili ge\u00e7ici veya ani ak\u0131m bilgilerini belirtin. Bir kesme e\u011frisi veya tepki karakteristi\u011fi gerekliyse, bu gereklili\u011fi a\u00e7\u0131k\u00e7a belirtin ve yaln\u0131zca tan\u0131d\u0131k bir harf kodundan se\u00e7im yapmak yerine, \u00fcreticiden kesin kan\u0131t talep edin.<\/p>\n\n<p class=\"wp-block-paragraph\">\u00d6ng\u00f6r\u00fclen konumdaki olas\u0131 k\u0131sa devre ak\u0131m\u0131n\u0131 belirtin. Bu de\u011fer normal ak\u0131mla ayn\u0131 de\u011fildir ve projenin elektriksel de\u011ferlendirmesinden elde edilmelidir. Belirtilen gerilim ve kutuplu konfig\u00fcrasyonda tam DC kesme kapasitesi de\u011ferini isteyin.<\/p>\n\n<h2 class=\"wp-block-heading\">Kutup ve Kutupluluk Kayd\u0131n\u0131 Talep Et<\/h2>\n\n<p class=\"wp-block-paragraph\">Gerekli say\u0131da anahtarlanan iletken say\u0131s\u0131n\u0131 ve varsa izolasyon hedefini belirtin, ard\u0131ndan \u00fcreticiden tam DC ba\u011flant\u0131 \u015femas\u0131n\u0131 isteyin. 1P, 2P veya 4P etiketi bir kablolama talimat\u0131 de\u011fildir. Baz\u0131 DC kesicilerin nominal de\u011ferleri, kutuplar\u0131n nas\u0131l ba\u011fland\u0131\u011f\u0131na ba\u011fl\u0131d\u0131r.<\/p>\n\n<p class=\"wp-block-paragraph\">ABB DC MCB k\u0131lavuzu, bu modele \u00f6zg\u00fc ili\u015fkiyi g\u00f6stermektedir. K\u0131lavuzdaki \u015femalar yaln\u0131zca ABB \u00fcr\u00fcnleri i\u00e7in ge\u00e7erlidir. RITOKS teklifi, \u00f6nerilen sipari\u015f kodu i\u00e7in ilgili \u015femay\u0131 ve polarite bilgilerini i\u00e7ermelidir.<\/p>\n\n<h2 class=\"wp-block-heading\">Tedarik\u00e7i Yan\u0131tlar\u0131n\u0131 Kar\u015f\u0131la\u015ft\u0131r\u0131labilir Hale Getirin<\/h2>\n\n<p class=\"wp-block-paragraph\">Kesin sipari\u015f kodu, nominal DC gerilimi, nominal ak\u0131m, devre kesme karakteristi\u011fi, kesme kapasitesi, kutup\/ba\u011flant\u0131 \u015femas\u0131, boyutlar, terminaller, montaj, \u00e7evresel s\u0131n\u0131rlar ve belge revizyonunu i\u00e7eren bir cevap tablosu kullan\u0131n. Pazarlama metinlerini oldu\u011fu gibi kabul etmek yerine, bilinmeyen alanlar\u0131 i\u015faretleyin.<\/p>\n\n<p class=\"wp-block-paragraph\">Yedek par\u00e7a talebinde bulunurken, kurulu kodu, i\u015faretlerin foto\u011fraflar\u0131n\u0131 ve mevcut \u00e7izimleri ekleyin; ancak boyutlar, terminaller ve elektriksel veriler kontrol edilene kadar \u201cdo\u011frudan tak\u0131labilir\u201d uyumluluk iddias\u0131nda bulunmay\u0131n. Yeni bir panel sipari\u015fi verirken, gerekli t\u00fcm sertifikalar\u0131 veya proje standartlar\u0131n\u0131 belirleyin ve genel bir logo yerine kesin kan\u0131t talep edin.<\/p>\n\n<h2 class=\"wp-block-heading\">Onaydan \u00d6nce Bir Kan\u0131t Dosyas\u0131 Haz\u0131rlay\u0131n<\/h2>\n\n<p class=\"wp-block-paragraph\">\u00d6nerilen DC MCB sipari\u015f kodu i\u00e7in bir inceleme tablosu olu\u015fturun. Uygulama verilerini sol s\u00fctuna, tedarik\u00e7inin sundu\u011fu kan\u0131tlar\u0131 ise sa\u011f s\u00fctuna yaz\u0131n. En az\u0131ndan devre kimli\u011fi, gerilim, ak\u0131m, ar\u0131za y\u00fck\u00fc ve belgelere ili\u015fkin kay\u0131tlar\u0131 saklay\u0131n. Bu sayede hangi bilgilerin projeden, hangi beyanlar\u0131n ise \u00fcreticiden geldi\u011fi net bir \u015fekilde anla\u015f\u0131l\u0131r.<\/p>\n\n<p class=\"wp-block-paragraph\">Kararda kullan\u0131lan veri sayfalar\u0131n\u0131n, \u00e7izimlerin ve tablolar\u0131n tam kopyalar\u0131n\u0131 ekleyin. Bunlar\u0131n revizyon veya eri\u015fim tarihlerini kaydedin ve belirtilen modele ait sat\u0131r\u0131 vurgulay\u0131n. Bir sat\u0131\u015f e-postas\u0131 kapsam\u0131 netle\u015ftirebilir; ancak karar, bir derecelendirme, ba\u011flant\u0131, devre kesme \u00f6zelli\u011fi, termal s\u0131n\u0131r veya test edilmi\u015f bir kombinasyona ba\u011fl\u0131 oldu\u011funda, teknik belgenin yerini sessizce almamal\u0131d\u0131r.<\/p>\n\n<p class=\"wp-block-paragraph\">Her bir ba\u011flant\u0131l\u0131 de\u011ferin ayn\u0131 sipari\u015f edilebilir konfig\u00fcrasyonu tan\u0131mlad\u0131\u011f\u0131n\u0131 kontrol edin. Benzer model isimleri genellikle ayn\u0131 g\u00f6vdeyi payla\u015f\u0131rken, kontrol beslemesi, ak\u0131m aral\u0131\u011f\u0131, kutuplar, terminaller, aksesuarlar veya \u00e7evresel s\u0131n\u0131rlar a\u00e7\u0131s\u0131ndan farkl\u0131l\u0131k g\u00f6sterebilir. Bir belge birka\u00e7 varyant\u0131 kaps\u0131yorsa, sayfadaki en geni\u015f aral\u0131\u011f\u0131 her varyant\u0131n kapasitesi olarak kabul etmek yerine, se\u00e7ilen sat\u0131r\u0131 i\u015faretleyin.<\/p>\n\n<h2 class=\"wp-block-heading\">Tedarik S\u00fcrecinde Yap\u0131lan Kontrol De\u011fi\u015fiklikleri<\/h2>\n\n<p class=\"wp-block-paragraph\">Tedarik\u00e7iler tekliflerini haz\u0131rlarken ba\u015fvuru kayd\u0131n\u0131 dondurulmu\u015f halde tutun. Gerilim, y\u00fck, \u00e7al\u0131\u015fma ko\u015fulu, ar\u0131za seviyesi, muhafaza veya \u00e7al\u0131\u015fma y\u00f6ntemi gibi bilgilerde de\u011fi\u015fiklik olmas\u0131 durumunda, g\u00fcncellenmi\u015f bir kay\u0131t yay\u0131nlay\u0131n ve her tedarik\u00e7iden aday \u00fcr\u00fcn\u00fc yeniden onaylamas\u0131n\u0131 isteyin. Aksi takdirde, e-posta konusu ve \u00fcr\u00fcn grubu de\u011fi\u015fmemi\u015f olsa bile, sat\u0131n alma birimi farkl\u0131 gereksinimler i\u00e7in haz\u0131rlanm\u0131\u015f teklifleri kar\u015f\u0131la\u015ft\u0131rabilir.<\/p>\n\n<p class=\"wp-block-paragraph\">Ayn\u0131 kural\u0131 ikame \u00fcr\u00fcnler i\u00e7in de uygulay\u0131n. Fiyat veya temin edilebilirlik nedeniyle \u00f6nerilen bir ikame \u00fcr\u00fcn, kendine ait sipari\u015f kodu ve destekleyici belgelerle birlikte teknik inceleme a\u015famas\u0131na geri g\u00f6nderilir. Yaln\u0131zca nominal ak\u0131m, \u00fcr\u00fcn \u015fekli veya montaj y\u00f6nteminin orijinal adaya benzemesi nedeniyle bunu onaylamay\u0131n. \u0130kame i\u015flemi, ancak gerekli i\u015flevler ve ko\u015fullar yeniden kontrol edildi\u011finde tamamlanm\u0131\u015f say\u0131l\u0131r.<\/p>\n\n<h2 class=\"wp-block-heading\">\u0130hale S\u00fcrecinde S\u0131k G\u00f6r\u00fclen Hatalar<\/h2>\n\n<ul class=\"wp-block-list\"><li>Uygulama ba\u011flam\u0131n\u0131 tan\u0131mlamadan, tek bir ana nominal de\u011ferden DC MCB se\u00e7mek.<\/li><li>Kapsam\u0131n\u0131 teyit etmeden kom\u015fu bir modele ait bir \u015fema, e\u011fri veya aksesuar tablosunu kullanmak.<\/li><li>Bir \u00fcr\u00fcn kategorisi sayfas\u0131n\u0131 veya pazarlama g\u00f6rselini, tam model kan\u0131t\u0131 olarak de\u011ferlendirmek.<\/li><li>Sadece cihazdan olu\u015fan bir teklif ile montajl\u0131 veya aksesuarlar dahil bir teklifi kar\u015f\u0131la\u015ft\u0131rma.<\/li><li>Ticari teklifin revize edilmesi s\u0131ras\u0131nda, hen\u00fcz \u00e7\u00f6z\u00fclmemi\u015f bir teknik konunun ortadan kalkmas\u0131na izin vermek.<\/li><\/ul>\n\n<p class=\"wp-block-paragraph\">Ticari kar\u015f\u0131la\u015ft\u0131rma yapmadan \u00f6nce bu hatalar\u0131 giderin. Teknik inceleme uzman\u0131, haf\u0131zas\u0131na g\u00fcvenmek zorunda kalmadan kabul edilen her bir beyan\u0131 proje kayd\u0131na veya ilgili belgeye kadar izleyebilmelidir. B\u00f6ylelikle, sat\u0131n alma birimi, sipari\u015f verildikten sonra se\u00e7im s\u00fcrecini yeniden ba\u015flatmak yerine, fiyat, miktar, var\u0131\u015f yeri ve teslim s\u00fcresini sabit bir teknik referans noktas\u0131 ile kar\u015f\u0131la\u015ft\u0131rabilir.<\/p>\n\n<h2 class=\"wp-block-heading\">Tedarik\u00e7i Tekliflerini Kar\u015f\u0131la\u015ft\u0131rma Y\u00f6ntemleri<\/h2>\n\n<p class=\"wp-block-paragraph\">Her bir DC MCB teklifini, sabitlenmi\u015f bir uygulama kayd\u0131yla kar\u015f\u0131la\u015ft\u0131r\u0131n. Birka\u00e7 farkl\u0131 varyanttan en iyi de\u011ferleri birle\u015ftirmeyin veya teklif edilen sipari\u015f kodunun nominal de\u011feri olarak \u00fcr\u00fcn ailesinin maksimum de\u011ferini kabul etmeyin. \u0130ki teklifin ger\u00e7ekten e\u015fde\u011fer olup olmad\u0131\u011f\u0131n\u0131 sat\u0131n alma biriminin g\u00f6rebilmesi i\u00e7in, her bir de\u011ferin yan\u0131nda belge revizyonunu, test ko\u015fullar\u0131n\u0131 ve doldurulmam\u0131\u015f alanlar\u0131 belirtin.<\/p>\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Kar\u015f\u0131la\u015ft\u0131rma noktas\u0131<\/th><th>Gerekli kan\u0131tlar<\/th><th>Kabul etmeyin<\/th><\/tr><\/thead><tbody><tr><td>Teklif Talebi alan\u0131<\/td><td>Kabul edilebilir yan\u0131t<\/td><td>Yetersiz yan\u0131t<\/td><\/tr><tr><td>Gerilim\/kutuplar<\/td><td>DC devresinin kesin \u015femas\u0131 ve ba\u011flant\u0131 \u015femas\u0131<\/td><td>Yaln\u0131zca aile \u00fcst s\u0131n\u0131r\u0131<\/td><\/tr><tr><td>Ar\u0131za derecesi<\/td><td>Belirtilen gerilimde kopma kapasitesi<\/td><td>Niteliksiz kA de\u011feri<\/td><\/tr><tr><td>Gezi<\/td><td>Model i\u00e7in kesin e\u011fri\/fonksiyonlar<\/td><td>Genel \u201cDC MCB\u201d<\/td><\/tr><tr><td>Belgeler<\/td><td>Teknik veri sayfas\u0131 ve revizyon<\/td><td>Sadece katalog g\u00f6rseli<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n<figure data-spectra-id=\"spectra-900dc7ee-87a1-4fb5-8aac-9d7c22bb1799\" class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-006-BODY-02.webp\" alt=\"Bir DC MCB teklifi i\u00e7in tedarik\u00e7i yan\u0131tlar\u0131na dayal\u0131 kan\u0131t denetimi\" class=\"wp-image-1291\" width=\"1400\" height=\"1050\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-006-BODY-02.webp 1400w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-006-BODY-02-600x450.webp 600w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-006-BODY-02-300x225.webp 300w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-006-BODY-02-1024x768.webp 1024w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-006-BODY-02-768x576.webp 768w\" sizes=\"auto, (max-width: 1400px) 100vw, 1400px\" \/><figcaption class=\"wp-element-caption\">Onay vermeden \u00f6nce modelin tam ad\u0131n\u0131, teknik \u00f6zellik belgesini, e\u011fri grafi\u011fini, kopma ve terminal kan\u0131tlar\u0131n\u0131 kontrol edin.<\/figcaption><\/figure>\n\n\n<p class=\"wp-block-paragraph\">Bir teklif, teknik a\u00e7\u0131dan eksik olsa bile ticari a\u00e7\u0131dan cazip kalabilir. Eksik verileri \u201challetilmesi gereken i\u015f\u201d olarak i\u015faretleyin ve tedarik\u00e7iden ilgili sayfan\u0131n, \u00e7izimin veya bile\u015fen tablosunun tam kopyas\u0131n\u0131 isteyin. Fiyat ve teslim s\u00fcresi, ancak teknik kapsam netle\u015ftirildikten sonra kar\u015f\u0131la\u015ft\u0131r\u0131lmal\u0131d\u0131r. Bu, daha d\u00fc\u015f\u00fck maliyetli ancak daha s\u0131n\u0131rl\u0131 bir teklifin, eksiksiz ve belgelenmi\u015f bir \u00e7\u00f6z\u00fcmle e\u015fde\u011fermi\u015f gibi g\u00f6r\u00fcnmesini engeller.<\/p>\n\n<h2 class=\"wp-block-heading\">Karar \u0130\u015f Ak\u0131\u015f\u0131<\/h2>\n\n<ul class=\"wp-block-list\"><li>Devrenin ve \u015falterin yerini belirtin.<\/li><li>Gerilim aral\u0131\u011f\u0131n\u0131, y\u00fck ak\u0131m\u0131n\u0131 ve ge\u00e7ici davran\u0131\u015f\u0131n\u0131 kaydedin.<\/li><li>Yerel olas\u0131 ar\u0131za ak\u0131m\u0131n\u0131 belirleyin.<\/li><li>Devlet kurallar\u0131, izolasyon ve \u00e7evresel gereklilikler.<\/li><li>Tam sipari\u015f kodunu ve eksiksiz destekleyici belgeleri talep edin.<\/li><li>Yan\u0131tlar\u0131 alan baz\u0131nda kar\u015f\u0131la\u015ft\u0131r\u0131n ve a\u00e7\u0131kl\u0131\u011fa kavu\u015fturmak i\u00e7in eksiklikleri belirtin.<\/li><\/ul>\n\n<p class=\"wp-block-paragraph\">Her a\u015famada, proje girdileri ile tedarik\u00e7inin sundu\u011fu kan\u0131tlar aras\u0131ndaki s\u0131n\u0131r\u0131 koruyun. Proje ekibi, uygulamay\u0131 ve gerekli i\u015flevleri tan\u0131mlar; tedarik\u00e7i ise kesin bir \u00fcr\u00fcn belirler ve ilgili belgeleri sunar. Taraflardan hi\u00e7biri, g\u00f6r\u00fcn\u00fc\u015ften, benzer bir modelden veya ortak bir genel derecelendirme notundan \u00e7\u0131kar\u0131mlarda bulunarak kan\u0131t eksikli\u011fini gidermemelidir.<\/p>\n\n<h2 class=\"wp-block-heading\">Teklif Talebi Haz\u0131rl\u0131k Kontrol Listesi<\/h2>\n\n<p class=\"wp-block-paragraph\">DC MCB teklif talebi kontrol listesi i\u00e7in faydal\u0131 bir teklif talebi, yan\u0131tlanmas\u0131 kolay olacak kadar \u00f6zl\u00fc, ancak \u00f6rt\u00fck varsay\u0131mlar\u0131 \u00f6nleyecek kadar kapsaml\u0131 olmal\u0131d\u0131r. Mevcut proje kay\u0131tlar\u0131n\u0131 ekleyin ve bilinmeyen de\u011ferleri soru olarak belirtin. Tedarik\u00e7iden, genel bir \u00fcr\u00fcn grubu \u00f6nerisi yerine, sipari\u015f verilebilecek kesin bir kodla yan\u0131t vermesini isteyin.<\/p>\n\n<ul class=\"wp-block-list\"><li>Uygulama ve devre konumu<\/li><li>Normal ve maksimum do\u011fru ak\u0131m gerilimi<\/li><li>S\u00fcrekli ak\u0131m ve ani ak\u0131m\/ge\u00e7ici ak\u0131m kan\u0131tlar\u0131<\/li><li>Beklenen k\u0131sa devre ak\u0131m\u0131<\/li><li>Direk ve ba\u011flant\u0131 gereklilikleri<\/li><li>Montaj, terminaller ve ortam ko\u015fullar\u0131<\/li><li>Tam model, belgeler, miktar ve var\u0131\u015f yeri<\/li><\/ul>\n\n<p class=\"wp-block-paragraph\">G\u00fcncel teknik veri sayfas\u0131 s\u00fcr\u00fcm\u00fcn\u00fc talep edin ve herhangi bir sertifikasyon, koordinasyon veya uyumluluk iddias\u0131n\u0131n kapsam\u0131n\u0131 belirleyin. Yan\u0131tta bir alternatif \u00f6neriliyorsa, o alternatif i\u00e7in de ayn\u0131 kan\u0131t setini talep edin. Ticari \u015fartlar\u0131n \u00e7\u00f6z\u00fclmemi\u015f m\u00fchendislik sorunlar\u0131n\u0131 g\u00f6lgelememesi i\u00e7in, teknik girdilerin ard\u0131ndan miktar\u0131 ve var\u0131\u015f yerini kaydedin.<\/p>\n\n<h2 class=\"wp-block-heading\">Sipari\u015fin Serbest B\u0131rak\u0131lmas\u0131ndan \u00d6nceki Durdurma Ko\u015fullar\u0131<\/h2>\n\n<p class=\"wp-block-paragraph\">Yay\u0131n a\u00e7\u0131s\u0131ndan kritik bir girdi bilinmiyorsa, belirtilen model belirsizse veya gerekli bir derecelendirme yaln\u0131zca ba\u015fka bir \u00fcreticinin belgesiyle destekleniyorsa, sipari\u015fi onaylamay\u0131n. Ayr\u0131ca, bir kombinasyon talebinde kesin bile\u015fen kodlar\u0131 eksikse veya bir \u015fema farkl\u0131 \u00fcr\u00fcn ailelerinde yeniden kullan\u0131l\u0131yorsa da i\u015flemi durdurun. Bunlar, editoryal ayr\u0131nt\u0131lar de\u011fil, kan\u0131t eksiklikleridir.<\/p>\n\n<p class=\"wp-block-paragraph\">Nihai onay kayd\u0131nda, se\u00e7ilen \u00f6\u011fenin ne i\u015fe yarad\u0131\u011f\u0131, kapsam\u0131 d\u0131\u015f\u0131nda kalan unsurlar ve karar\u0131 destekleyen belgelerin tam olarak hangileri oldu\u011fu belirtilmelidir. Uygulama, g\u00f6rev, ortam veya \u00f6nerilen modelde de\u011fi\u015fiklik olmas\u0131 durumunda, \u00f6nceki sonucu aynen devralmak yerine ilgili kontrolleri yeniden ba\u015flat\u0131n.<\/p>\n\n<h2 class=\"wp-block-heading\">S\u0131k Sorulan Sorular<\/h2>\n\n<h3 class=\"wp-block-heading\">Sadece gerilim ve ak\u0131m de\u011ferlerini g\u00f6nderebilir miyim?<\/h3>\n\n<p class=\"wp-block-paragraph\">Bu yeterli de\u011fildir. Ar\u0131za seviyesi, direk ba\u011flant\u0131s\u0131, \u00e7al\u0131\u015fma \u015fartlar\u0131 ve belgeleme gereklilikleri de gereklidir.<\/p>\n\n<h3 class=\"wp-block-heading\">Belirli bir seyir e\u011frisi talep etmeli miyim?<\/h3>\n\n<p class=\"wp-block-paragraph\">Yaln\u0131zca y\u00fck ve koruma tasar\u0131m\u0131 bunu gerektirdi\u011finde; \u00fcreticiden kesin kan\u0131t talep edin.<\/p>\n\n<h3 class=\"wp-block-heading\">Bir foto\u011fraf, yedek par\u00e7an\u0131n uyumlu oldu\u011funu kan\u0131tlayabilir mi?<\/h3>\n\n<p class=\"wp-block-paragraph\">Hay\u0131r. Boyutlar\u0131, terminalleri, ba\u011flant\u0131lar\u0131, nominal de\u011ferleri ve devre kesme davran\u0131\u015f\u0131n\u0131 kontrol edin.<\/p>\n\n<h2 class=\"wp-block-heading\">\u0130lgili RITOKS \u00dcr\u00fcnleri ve K\u0131lavuzlar<\/h2>\n\n<p class=\"wp-block-paragraph\">Bu ba\u011flant\u0131lar\u0131 ayr\u0131 kategori, \u00fcr\u00fcn ve e\u011fitim kay\u0131tlar\u0131 olarak kullan\u0131n. Ba\u011flamsal bir ba\u011flant\u0131, kar\u015f\u0131l\u0131kl\u0131 de\u011fi\u015ftirilebilirlik, uyumluluk veya koordineli bir birle\u015fim iddias\u0131nda bulunmaz.<\/p>\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/ritoks.com\/tr\/product-category\/dc-power-protection\/dc-circuit-breakers\/dc-miniature-circuit-breakers\/\">DC MCB \u00fcr\u00fcn kategorisi<\/a><\/p>\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/ritoks.com\/tr\/products\/2p-dc-miniature-circuit-breaker-500-1000v-6-63a\/\">2P DC MCB serisi<\/a><\/p>\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/ritoks.com\/tr\/products\/high-current-dc-miniature-circuit-breaker-12-125v-63-250a\/\">Y\u00fcksek ak\u0131ml\u0131, d\u00fc\u015f\u00fck gerilimli DC MCB serisi<\/a><\/p>\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/ritoks.com\/tr\/dc-mcb-selection-guide\/\">DC MCB se\u00e7im k\u0131lavuzu<\/a><\/p>\n\n<h2 class=\"wp-block-heading\">Teknik Kaynaklar<\/h2>\n\n<p class=\"wp-block-paragraph\">A\u015fa\u011f\u0131daki g\u00fcvenilir kaynaklar, yaln\u0131zca a\u015fa\u011f\u0131da belirtilen genel kavramlar\u0131 desteklemektedir. Bu kaynaklardaki \u00fcr\u00fcn de\u011ferleri, \u015femalar, kombinasyonlar ve onaylar, RITOKS \u00fcr\u00fcnlerine uygulanmaz.<\/p>\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/library.e.abb.com\/public\/4009e91864554accb8c325cb552f18e0\/9AKK108468A3912_en_9AKK108468A3912_B01_D_B01%20Electrical%20installation%20solutions%20for%20buildings_part%20B01%20MCBs%20_EN_%20%28PDF%29.pdf\" target=\"_blank\" rel=\"noopener\">ABB, DC Uygulamalar\u0131 i\u00e7in Minyat\u00fcr Devre Kesiciler<\/a><\/p>\n\n<p class=\"wp-block-paragraph\">DC gerilim, kutuplar, polarite ve kesme kapasitesinin tam seri do\u011frulamas\u0131n\u0131 destekler. ABB \u015femalar\u0131 ve teknik \u00f6zellikleri, RITOKS cihazlar\u0131 i\u00e7in ge\u00e7erli de\u011fildir.<\/p>\n\n<h2 class=\"wp-block-heading\">Belirli Bir Modelin \u0130ncelenmesini Talep Et<\/h2>\n\n<p class=\"wp-block-paragraph\">Kaydedilen uygulama gereksinimlerini, belgelerle ilgili kesin sorular\u0131, miktar\u0131 ve teslimat adresini RITOKS ileti\u015fim formu arac\u0131l\u0131\u011f\u0131yla g\u00f6nderin. Bir RFQ, kesin model incelemesi talep eder; bu k\u0131lavuz, kablolama tasar\u0131m\u0131n\u0131, kurulumu veya otomatik ikameyi onaylamaz.<\/p>\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/ritoks.com\/tr\/contact-us\/\">RITOKS ile ileti\u015fime ge\u00e7in<\/a><\/p>","protected":false},"excerpt":{"rendered":"<p>Gerilim, y\u00fck, ar\u0131za seviyesi, kutuplar, polarite, a\u00e7ma de\u011feri ve kesin model ile ilgili belgeleme gerekliliklerini i\u00e7eren bir DC MCB teklif talebi haz\u0131rlay\u0131n.<\/p>","protected":false},"author":1,"featured_media":1289,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"no-sidebar","site-content-layout":"page-builder","ast-site-content-layout":"full-width-container","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"disabled","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"disabled","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ritoks_resource_detail_renderer":"viox","ritoks_resource_product_cat_term_id":0,"footnotes":""},"categories":[64],"tags":[],"class_list":["post-1305","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-circuit-protection"],"acf":[],"spectra_blocks_featured_image_url":{"thumbnail":{"url":"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-006-HERO-01-150x150.webp","width":150,"height":150},"medium":{"url":"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-006-HERO-01-300x169.webp","width":300,"height":169},"medium_large":{"url":"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-006-HERO-01-768x432.webp","width":768,"height":432},"large":{"url":"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-006-HERO-01-1024x576.webp","width":1024,"height":576},"full":{"url":"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/MT-006-HERO-01.webp","width":1600,"height":900}},"spectra_blocks_author_info":{"display_name":"RITOKS","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/6d7d0fc73468198f994ab13ef6eb6558c53b6ed1ad86364d5165efe8bdf8eb4a?s=96&d=mm&r=g","author_link":"https:\/\/ritoks.com\/tr\/author\/dazzlingwqbgmail-com\/","description":""},"_links":{"self":[{"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/posts\/1305","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/comments?post=1305"}],"version-history":[{"count":1,"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/posts\/1305\/revisions"}],"predecessor-version":[{"id":1313,"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/posts\/1305\/revisions\/1313"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/media\/1289"}],"wp:attachment":[{"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/media?parent=1305"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/categories?post=1305"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/tags?post=1305"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}