{"id":2252,"date":"2026-10-06T06:17:53","date_gmt":"2026-10-06T06:17:53","guid":{"rendered":"http:\/\/ritoks.com\/"},"modified":"2026-10-06T06:17:53","modified_gmt":"2026-10-06T06:17:53","slug":"current-transformer-accuracy-class-burden","status":"publish","type":"post","link":"https:\/\/ritoks.com\/tr\/current-transformer-accuracy-class-burden\/","title":{"rendered":"Current Transformer Accuracy Class and Burden: Verification Guide"},"content":{"rendered":"<p class=\"wp-block-paragraph\">Current transformer accuracy class and burden describe a measurement system, not a standalone quality score. A CT specified for a particular class is assessed under defined conditions. The connected meter, cable and terminals impose a real secondary burden that must fit the evidence for the exact CT.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This guide explains the questions a buyer should put in the technical file. It does not assign universal accuracy to a CT family or prescribe a ratio from the equipment name alone.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Karar Al\u0131m\u0131nda Kullan\u0131lan Verilere Genel Bak\u0131\u015f<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>\u0130nceleme alan\u0131<\/th><th>Al\u0131c\u0131n\u0131n kaydetti\u011fi bilgiler<\/th><th>Talep edilecek deliller<\/th><\/tr><\/thead><tbody><tr><td>Primary side<\/td><td>Expected current range and conductor arrangement<\/td><td>Load record and installation drawing<\/td><\/tr><tr><td>Secondary side<\/td><td>Output expected by receiving device<\/td><td>CT and meter input documents<\/td><\/tr><tr><td>Y\u00fck<\/td><td>Meter input plus lead and connection contribution<\/td><td>Circuit estimate and exact CT data<\/td><\/tr><tr><td>Do\u011fruluk<\/td><td>Required class under relevant conditions<\/td><td>Exact CT datasheet and test basis<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure data-spectra-id=\"spectra-a9a5fd29-975f-4b38-99c9-22357811e7b7\" class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1400\" height=\"1050\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/current-transformer-accuracy-class-burden-body-01.webp\" alt=\"Current Transformer Accuracy Class and Burden: Verification Guide input diagram: primary range, secondary output, accuracy class, rated burden\" class=\"wp-image-2250\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/current-transformer-accuracy-class-burden-body-01.webp 1400w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/current-transformer-accuracy-class-burden-body-01-300x225.webp 300w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/current-transformer-accuracy-class-burden-body-01-1024x768.webp 1024w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/current-transformer-accuracy-class-burden-body-01-768x576.webp 768w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/current-transformer-accuracy-class-burden-body-01-16x12.webp 16w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/current-transformer-accuracy-class-burden-body-01-600x450.webp 600w\" sizes=\"auto, (max-width: 1400px) 100vw, 1400px\" \/><figcaption class=\"wp-element-caption\">Map the project inputs for current transformers before screening candidates.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Define the measurement purpose<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A monitoring display, energy accounting function and control input may demand different evidence. State what the reading will be used for, its relevant operating range and the consequences of error. The CT ratio and class should follow that purpose.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">If the circuit rarely operates near its nominal maximum, consider performance over the actual range rather than selecting from one full-scale number. Ask the supplier for the exact conditions to which its accuracy statement applies.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Understand class as a conditional statement<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">An accuracy class describes performance under a defined standard or test basis. It is not a promise that the installed meter will show that error under every current, frequency, temperature or burden.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Read the complete CT datasheet, including the specified output, rated burden and class conditions. Do not transfer a class label from one variant, core size or ratio to another.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Calculate the complete secondary burden<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The receiving meter input is only part of the load seen by the CT secondary. Lead resistance, terminals and other connected devices can contribute. Longer runs and multiple instruments may materially change the burden.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Document the secondary route and the actual devices attached to it. Compare the resulting burden with the exact CT evidence; if the circuit changes, update the assessment. Avoid treating a catalog burden value as a measurement of the installed circuit.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Match ratio and output to the meter<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The CT primary ratio should represent the expected current range, while the secondary output must match the meter input. A number in the product title does not prove the output of every order code or compatibility with every panel meter.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Obtain both connection diagrams and the meter configuration method. Record any programmable ratio in the commissioning file so the display and exported data use the same scaling.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Check physical installation<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Solid-core and split-core devices may solve different installation constraints. Confirm conductor or busbar dimensions, window space, mounting access and orientation. The choice of housing also affects how the secondary circuit can be routed and inspected.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">If retrofitting a live panel is proposed, the work method needs a separate safety review by qualified personnel. Do not infer installation permission from the split-core label.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Verify the system, not only the CT<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A CT, meter, wiring path and configured ratio form one measurement chain. Commissioning should check polarity or direction where relevant, expected response and scaling under known conditions.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Keep the as-built secondary diagram and configuration alongside the selected CT order code. This makes it possible to diagnose a discrepancy between the meter display and another measurement without guessing which component changed.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Request evidence that matches the quoted item<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Ask for exact ratio, output, rated burden, accuracy basis, physical drawing and installation instructions for the proposed CT. Separate what the product page shows from what the order-specific documents prove.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A proposal remains open if the accuracy class is visible but the burden or operating conditions are not. Resolve those fields before approval, especially when the reading supports a commercial or control decision.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Kesin Modele Dayal\u0131 Kan\u0131t Dosyas\u0131 Olu\u015fturun<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A category or product-family page helps locate relevant options; it does not by itself approve one variant. For current transformers, keep the full proposed order code, current datasheet, terminal or mounting drawing, operating instructions and any project calculation together. Read the conditions attached to each rating or function. If the evidence belongs to a neighboring model, request the correct document instead of carrying the claim across.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Proje ekibi, sistem girdileri ve kabul kriterlerinden sorumludur. Tedarik\u00e7i ise teklif edilen kalemle ilgili kan\u0131tlardan sorumludur. Teknik incelemede, her bir zorunlu gereksinimi, buna yan\u0131t veren tam belge ve revizyonun yan\u0131na yerle\u015ftirin. Eksik bir alan\u0131 \u201ca\u00e7\u0131k\u201d, \u201cko\u015fullu\u201d veya \u201cdesteklenmiyor\u201d olarak i\u015faretleyin. Bu, izlenebilir bir karar olu\u015fturur ve uygun bir ba\u015fl\u0131k de\u011ferinin, uyumsuz bir ba\u011flant\u0131 veya kurulum ko\u015fulunu gizlemesini \u00f6nler.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">T\u00fcm Teklifleri Kar\u015f\u0131la\u015ft\u0131r\u0131n<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>\u00dcr\u00fcn<\/th><th>Kar\u015f\u0131la\u015ft\u0131rmada kay\u0131t<\/th><th>Sebep<\/th><\/tr><\/thead><tbody><tr><td>Sipari\u015f edilebilir \u00fcr\u00fcn<\/td><td>Tam kod, model ve birlikte verilen aksesuarlar<\/td><td>Aile d\u00fczeyindeki varsay\u0131mlar\u0131 \u00f6nler<\/td><\/tr><tr><td>Uygulama e\u015fle\u015fmesi<\/td><td>Her bir proje girdisine ili\u015fkin yaz\u0131l\u0131 yan\u0131t<\/td><td>\u0130stisnalar\u0131 g\u00f6r\u00fcn\u00fcr tutar<\/td><\/tr><tr><td>Belgeler<\/td><td>Teknik veri sayfas\u0131, \u00e7izim, kullan\u0131m k\u0131lavuzu ve revizyonlar<\/td><td>Sunulan \u00fcr\u00fcnle ilgili hak talepleri<\/td><\/tr><tr><td>A\u00e7\u0131k kalan konular<\/td><td>Sahibi ve a\u00e7\u0131kl\u0131\u011fa kavu\u015fturulmas\u0131 gereken son tarih<\/td><td>Sessizce kabullenmeyi \u00f6nler<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure data-spectra-id=\"spectra-3e6f0c86-75fa-497b-8442-59622f23e188\" class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1400\" height=\"1050\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/current-transformer-accuracy-class-burden-body-02.webp\" alt=\"Current Transformer Accuracy Class and Burden: Verification Guide evidence diagram: meter input, lead length, connection, test record\" class=\"wp-image-2251\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/current-transformer-accuracy-class-burden-body-02.webp 1400w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/current-transformer-accuracy-class-burden-body-02-300x225.webp 300w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/current-transformer-accuracy-class-burden-body-02-1024x768.webp 1024w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/current-transformer-accuracy-class-burden-body-02-768x576.webp 768w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/current-transformer-accuracy-class-burden-body-02-16x12.webp 16w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/current-transformer-accuracy-class-burden-body-02-600x450.webp 600w\" sizes=\"auto, (max-width: 1400px) 100vw, 1400px\" \/><figcaption class=\"wp-element-caption\">Compare current transformers offers using exact-model evidence and open questions.<\/figcaption><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Her teklif i\u00e7in ayn\u0131 proje \u00f6zetini kullan\u0131n. Teknik kapsam standart hale getirildikten sonra fiyat ve teslim s\u00fcresi gibi ticari ko\u015fullar kar\u015f\u0131la\u015ft\u0131r\u0131labilir. Eksik aksesuarlar\u0131, desteklenmeyen de\u011ferleri veya \u00e7\u00f6z\u00fclmemi\u015f kablolama varsay\u0131mlar\u0131n\u0131, belgelenmi\u015f bir teklifle e\u015fde\u011fer olarak de\u011ferlendirmeyin. Bir alternatif \u00f6nerilirse, hangi girdilerin de\u011fi\u015fti\u011fini sorun ve etkilenen incelemeyi tekrarlay\u0131n.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Kurulum ve Kabul \u0130ncelemesi<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Kurulumdan \u00f6nce, teslim edilen etiketin, tam kodun ve aksesuarlar\u0131n onayl\u0131 kay\u0131tla uyumlu oldu\u011funu do\u011frulay\u0131n. Terminalleri, montaj\u0131, iletken eri\u015fimini ve belirtilen y\u00f6nlendirmeyi tam talimatlarla kar\u015f\u0131la\u015ft\u0131r\u0131n. Onayl\u0131 s\u00fcr\u00fcmle fiziksel olarak benzer g\u00f6r\u00fcnen bir \u00fcr\u00fcn, yine de farkl\u0131 bir elektriksel konfig\u00fcrasyona, kontrol se\u00e7ene\u011fine veya test esas\u0131na sahip olabilir.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Plan an as-built check that addresses the project&#8217;s real risks. This may involve wiring against the approved diagram, functional response, measurements under representative operating states and confirmation of any communication or alarm feature. Record the conditions and results. The acceptance plan should come from the application and supplier evidence, not from a generic article checklist.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Teklif Talebi Kontrol Listesi<\/h2>\n\n\n\n<ul class=\"wp-block-list\"><li>Identify the circuit, equipment and location that current transformers must serve.<\/li><li>Uygulamay\u0131 tan\u0131mlayan sistem \u00e7izimini ve \u00e7al\u0131\u015fma durumlar\u0131n\u0131 ekleyin.<\/li><li>Record primary range and its source document.<\/li><li>Record secondary output and its source document.<\/li><li>Record accuracy class and its source document.<\/li><li>Record rated burden and its source document.<\/li><li>Confirm the exact-model evidence for meter input.<\/li><li>Confirm the exact-model evidence for lead length.<\/li><li>Confirm the exact-model evidence for connection.<\/li><li>Confirm the exact-model evidence for test record.<\/li><li>Sipari\u015f kodunun tamam\u0131n\u0131, aksesuarlar\u0131, \u00e7izimleri ve teknik \u00f6zellik belgesinin revizyonunu talep edin.<\/li><li>\u0130stisnalar\u0131, varsay\u0131mlar\u0131, alternatifleri ve hen\u00fcz \u00e7\u00f6z\u00fclmemi\u015f m\u00fchendislik konular\u0131n\u0131 sorun.<\/li><\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Teklif Talebi, tedarik\u00e7inin eksik proje de\u011ferlerini uydurmaya gerek kalmadan yan\u0131t verebilece\u011fi kadar ayr\u0131nt\u0131l\u0131 olmal\u0131d\u0131r. Temel bir girdi hen\u00fcz bilinmiyorsa, bunu bir soru olarak belirtin ve kimin belirleyece\u011fini a\u00e7\u0131k\u00e7a ifade edin. Bir varsay\u0131m\u0131 derecelendirme, uygunluk beyan\u0131 veya onaylanm\u0131\u015f kurulum y\u00f6ntemi haline getirmeyin.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Karar\u0131 Etkileyen Fakt\u00f6rler Nelerdir?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A decision can change when the source arrangement, load behavior, environment, installation geometry or required function changes. Revisit the selected current transformers whenever one of those inputs moves outside the approved brief. Recheck the order code and the exact evidence affected by the change; do not rely on a previous approval for a circuit that now asks the component to do different work.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Proje \u00f6zeti, tedarik\u00e7inin yan\u0131t\u0131 ve kabul edilen istisna listesinin k\u0131sa bir revizyon ge\u00e7mi\u015fini tutun. Bu kay\u0131t, m\u00fchendislik, sat\u0131n alma ve devreye alma ekiplerinin ayn\u0131 s\u00fcr\u00fcm \u00fczerinden \u00e7al\u0131\u015fmas\u0131na yard\u0131mc\u0131 olur. Bu, \u00f6zellikle bir teklifin revize edilmesi, bir ikame \u00fcr\u00fcn\u00fcn sunulmas\u0131 veya ilk kar\u015f\u0131la\u015ft\u0131rmadan sonra panel tasar\u0131m\u0131nda de\u011fi\u015fiklik yap\u0131lmas\u0131 durumunda yararl\u0131d\u0131r.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Onaydan \u00d6nce \u00c7\u00f6z\u00fclmesi Gereken Sorular<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Ask who owns each remaining technical question for the proposed current transformers. The buyer should confirm the system inputs and installation constraints; the supplier should confirm the exact item, included options and applicable documentation. Put the answer and document revision beside the question. An unanswered point should remain visible in the comparison rather than being converted into an assumed feature.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Bir teklifte alternatif sunuldu\u011funda, de\u011fi\u015ftirilen devre, montaj veya performans esaslar\u0131na ili\u015fkin yaz\u0131l\u0131 bir a\u00e7\u0131klama isteyin. Yeni \u00e7izimleri proje m\u00fchendisiyle birlikte inceleyin ve \u00f6nerilen de\u011fi\u015fikli\u011fin kabul edilebilir olup olmad\u0131\u011f\u0131n\u0131 kaydedin. Bir ikame, ticari a\u00e7\u0131dan e\u015fde\u011fer g\u00f6r\u00fcnse bile yeni bir teknik karard\u0131r. Bu durum, birden fazla tedarik\u00e7inin farkl\u0131 konfig\u00fcrasyonlar i\u00e7in benzer \u00fcr\u00fcn grubu etiketleri kulland\u0131\u011f\u0131 durumlarda \u00f6zellikle \u00f6nemlidir.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">S\u0131k Sorulan Sorular<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Does a higher accuracy class guarantee an accurate installation?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">No. The connected burden, current range, meter input, wiring and configuration also matter.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Can I connect any CT to any panel meter?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">No. Verify secondary output, input requirements, ratio configuration and wiring.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Is rated burden the same as actual burden?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">No. Rated burden is a product condition; actual burden is created by the installed secondary circuit.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Konuyla \u0130lgili RITOKS Sayfalar\u0131<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u00dcr\u00fcn ailesi ba\u011flam\u0131 i\u00e7in bkz. <a href=\"https:\/\/ritoks.com\/tr\/product-category\/electrical-measurement-monitoring\/current-transformers\/\">Elektriksel \u00d6l\u00e7\u00fcm ve \u0130zleme<\/a>. \u0130lgili yay\u0131nlanm\u0131\u015f \u00fcr\u00fcn sayfalar\u0131 \u015funlard\u0131r: <a href=\"https:\/\/ritoks.com\/tr\/products\/bh-0-66-60i-current-transformer-200-5a-1500-5a\/\">Bh 0 66 60i Current Transformer 200 5a 1500 5a<\/a>, <a href=\"https:\/\/ritoks.com\/tr\/products\/dp-series-split-core-current-transformer\/\">Dp Series Split Core Current Transformer<\/a>, <a href=\"https:\/\/ritoks.com\/tr\/products\/gta20l-precision-current-transformer-10a-100a\/\">Gta20l Precision Current Transformer 10a 100a<\/a>. \u00d6nerilen bir \u00fcr\u00fcn\u00fc kar\u015f\u0131la\u015ft\u0131r\u0131rken, s\u00f6z konusu \u00fcr\u00fcn\u00fcn g\u00fcncel ve tam modeline ait belgeleri kullan\u0131n.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Uygulamaya \u00f6zel bir fiyat teklifi i\u00e7in, <a href=\"https:\/\/ritoks.com\/tr\/contact-us\/\">proje \u00f6zetini RITOKS\u2019a g\u00f6nderin<\/a> yukar\u0131daki \u015femalar ve a\u00e7\u0131k u\u00e7lu sorularla birlikte.<\/p>","protected":false},"excerpt":{"rendered":"<p>Current Transformer Accuracy Class and Burden: Verification Guide. Review application inputs, exact-model documents and RFQ questions before selecting current transformers.<\/p>","protected":false},"author":1,"featured_media":2249,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ritoks_resource_detail_renderer":"viox","ritoks_resource_product_cat_term_id":120,"footnotes":""},"categories":[68],"tags":[],"class_list":["post-2252","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-electrical-measurement-monitoring"],"acf":[],"spectra_blocks_featured_image_url":{"thumbnail":{"url":"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/current-transformer-accuracy-class-burden-hero-01-150x150.webp","width":150,"height":150},"medium":{"url":"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/current-transformer-accuracy-class-burden-hero-01-300x169.webp","width":300,"height":169},"medium_large":{"url":"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/current-transformer-accuracy-class-burden-hero-01-768x432.webp","width":768,"height":432},"large":{"url":"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/current-transformer-accuracy-class-burden-hero-01-1024x576.webp","width":1024,"height":576},"full":{"url":"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/10\/current-transformer-accuracy-class-burden-hero-01.webp","width":1600,"height":900}},"spectra_blocks_author_info":{"display_name":"RITOKS","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/6d7d0fc73468198f994ab13ef6eb6558c53b6ed1ad86364d5165efe8bdf8eb4a?s=96&d=mm&r=g","author_link":"https:\/\/ritoks.com\/tr\/author\/dazzlingwqbgmail-com\/","description":""},"_links":{"self":[{"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/posts\/2252","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/comments?post=2252"}],"version-history":[{"count":1,"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/posts\/2252\/revisions"}],"predecessor-version":[{"id":2253,"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/posts\/2252\/revisions\/2253"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/media\/2249"}],"wp:attachment":[{"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/media?parent=2252"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/categories?post=2252"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/tags?post=2252"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}