{"id":668,"date":"2026-09-05T09:23:49","date_gmt":"2026-09-05T09:23:49","guid":{"rendered":"https:\/\/ritoks.com\/?p=668"},"modified":"2026-09-23T14:09:11","modified_gmt":"2026-09-23T14:09:11","slug":"how-to-choose-dc-circuit-breaker-mcb-vs-mccb","status":"publish","type":"post","link":"https:\/\/ritoks.com\/tr\/how-to-choose-dc-circuit-breaker-mcb-vs-mccb\/","title":{"rendered":"DC Devre Kesici Nas\u0131l Se\u00e7ilir: MCB ve MCCB Kar\u015f\u0131la\u015ft\u0131rmas\u0131"},"content":{"rendered":"<div class=\"wp-block-group alignfull has-ast-global-color-5-color has-ast-global-color-2-background-color has-text-color has-background is-layout-constrained wp-container-core-group-is-layout-154c5234 wp-block-group-is-layout-constrained\" style=\"padding-top:clamp(40px, 5.625vw, 72px);padding-right:24px;padding-bottom:clamp(40px, 5.625vw, 72px);padding-left:24px\">\n<h1 class=\"wp-block-heading\">DC Devre Kesici Nas\u0131l Se\u00e7ilir: MCB ve MCCB Kar\u015f\u0131la\u015ft\u0131rmas\u0131<\/h1>\n\n\n\n<figure data-spectra-id=\"spectra-74ca4a45-3605-4718-8f0e-705466184ad0\" class=\"wp-block-image size-full has-custom-border\" ><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/dc-mcb-mccb-solar-industrial-environment.jpg\" alt=\"G\u00fcne\u015f enerjisi ve end\u00fcstriyel DC elektrik ortamlar\u0131nda kullan\u0131lan DC MCB ve MCCB devre kesiciler\" class=\"wp-image-672\" width=\"1672\" height=\"941\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/dc-mcb-mccb-solar-industrial-environment.jpg 1672w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/dc-mcb-mccb-solar-industrial-environment-600x338.jpg 600w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/dc-mcb-mccb-solar-industrial-environment-300x169.jpg 300w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/dc-mcb-mccb-solar-industrial-environment-1024x576.jpg 1024w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/dc-mcb-mccb-solar-industrial-environment-768x432.jpg 768w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/dc-mcb-mccb-solar-industrial-environment-1536x864.jpg 1536w\" sizes=\"auto, (max-width: 1672px) 100vw, 1672px\" \/><figcaption class=\"wp-element-caption\">DC devre kesici se\u00e7eneklerini de\u011ferlendirirken kullan\u0131lan tipik DC MCB ve MCCB formatlar\u0131.<\/figcaption><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">DC minyat\u00fcr devre kesici (MCB) ile DC kal\u0131pl\u0131 g\u00f6vdeli devre kesici (MCCB) aras\u0131nda se\u00e7im yapmak, MCB\u2019leri \u201cd\u00fc\u015f\u00fck ak\u0131mlar\u201da, MCCB\u2019leri ise \u201cy\u00fcksek ak\u0131mlar\u201da atamak kadar basit de\u011fildir.\u201d<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-group alignfull is-layout-constrained wp-container-core-group-is-layout-4f00fe7e wp-block-group-is-layout-constrained\" style=\"padding-top:64px;padding-right:24px;padding-bottom:64px;padding-left:24px\">\n\n\n<p class=\"wp-block-paragraph\">Bu k\u0131sayol yan\u0131lt\u0131c\u0131 olabilir.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Mevcut <a href=\"https:\/\/ritoks.com\/tr\/product-category\/dc-power-protection\/\">RITOKS DC G\u00fc\u00e7 Koruma Sistemi<\/a> \u00dcr\u00fcn gruplar\u0131 bunun nedenini zaten ortaya koyuyor. Piyasaya s\u00fcr\u00fclen DIN ray\u0131 tipi DC MCB\u2019ler aras\u0131nda 6\u201363 A aral\u0131\u011f\u0131ndaki modellerin yan\u0131 s\u0131ra 63\u2013250 A aral\u0131\u011f\u0131ndaki y\u00fcksek ak\u0131m serisi de bulunurken, mevcut kal\u0131pl\u0131 g\u00f6vdeli DC kesici serisi ise 125 A ve 250 A \u00e7er\u00e7evelerini i\u00e7eriyor.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ba\u015fka bir deyi\u015fle, sadece ak\u0131m aral\u0131\u011f\u0131 tek ba\u015f\u0131na bir MCB ile bir MCCB\u2019yi g\u00fcvenilir bir \u015fekilde birbirinden ay\u0131rt etmeye yetmez.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Daha pratik bir DC devre kesici se\u00e7im s\u00fcrecinde \u015fu hususlar g\u00f6z \u00f6n\u00fcnde bulundurulur:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>DC sistem gerilimi<\/li>\n\n\n<li>\u00e7al\u0131\u015fma ak\u0131m\u0131<\/li>\n\n\n<li>gerekli kutup say\u0131s\u0131<\/li>\n\n\n<li>montaj \u015fekli<\/li>\n\n\n<li>mevcut \u00fcr\u00fcn konfig\u00fcrasyonu<\/li>\n\n\n<li>uygulama ba\u011flam\u0131<\/li>\n\n\n<li>kesicinin tam modeline ili\u015fkin do\u011frulanm\u0131\u015f veriler<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Bu k\u0131lavuzda, genel bir ak\u0131m e\u015fi\u011fine dayanmadan DC MCB ve MCCB se\u00e7eneklerinin nas\u0131l kar\u015f\u0131la\u015ft\u0131r\u0131laca\u011f\u0131 a\u00e7\u0131klanmaktad\u0131r.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"in-this-guide\">Bu K\u0131lavuzda<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"#quick-answer\">H\u0131zl\u0131 Cevap: MCB mi, yoksa MCCB mi?<\/a><\/li>\n\n\n<li><a href=\"#what-is-a-dc-mcb\">DC MCB Nedir?<\/a><\/li>\n\n\n<li><a href=\"#what-is-a-dc-mccb\">DC MCCB Nedir?<\/a><\/li>\n\n\n<li><a href=\"#why-current-alone-is-not-enough\">Neden Yaln\u0131zca Ak\u0131m Yeterli De\u011fildir?<\/a><\/li>\n\n\n<li><a href=\"#selection-process\">Pratik Bir Se\u00e7im S\u00fcreci<\/a><\/li>\n\n\n<li><a href=\"#common-mistakes\">S\u0131k G\u00f6r\u00fclen Se\u00e7im Hatalar\u0131<\/a><\/li>\n\n\n<li><a href=\"#frequently-asked-questions\">S\u0131k Sorulan Sorular<\/a><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"quick-answer\">H\u0131zl\u0131 Cevap: MCB mi, yoksa MCCB mi?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A\u015fa\u011f\u0131daki tablo, RITOKS \u00fcr\u00fcn ailesinin mevcut konumland\u0131rmas\u0131n\u0131 \u00f6zetlemektedir.<\/p>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table><thead><tr><th>Se\u00e7im Fakt\u00f6r\u00fc<\/th><th>DC MCB<\/th><th>DC MCCB<\/th><\/tr><\/thead><tbody><tr><td>Mevcut RITOKS montaj bi\u00e7imi<\/td><td>35 mm DIN ray\u0131<\/td><td>Panel \/ sabit montaj<\/td><\/tr><tr><td>Mevcut RITOKS direk se\u00e7enekleri<\/td><td>Modele ba\u011fl\u0131 olarak 1P \/ 2P<\/td><td>Mevcut yay\u0131nlanm\u0131\u015f ailede 2P<\/td><\/tr><tr><td>Yay\u0131nlanm\u0131\u015f g\u00fcncel \u00f6rnekler<\/td><td>6\u201363A ve 63\u2013250A serileri<\/td><td>125A \/ 250A \u015fasiler<\/td><\/tr><tr><td>Yay\u0131nlanm\u0131\u015f gerilim \u00f6rnekleri<\/td><td>12\u2013125 V, 500 V ve 500\u20131000 V DC serileri<\/td><td>500 V \/ 1000 V modelleri<\/td><\/tr><tr><td>Ana se\u00e7im yakla\u015f\u0131m\u0131<\/td><td>Elektrik ve kurulum gerekliliklerine tam olarak uyun<\/td><td>Elektrik ve kurulum gerekliliklerine tam olarak uyun<\/td><\/tr><tr><td>Sadece ak\u0131m, se\u00e7imi belirleyebilir mi?<\/td><td>Hay\u0131r<\/td><td>Hay\u0131r<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Bu, bir \u00fcr\u00fcn ailesi kar\u015f\u0131la\u015ft\u0131rmas\u0131d\u0131r; evrensel bir m\u00fchendislik kural\u0131 de\u011fildir.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Mevcut ticari se\u00e7enekler i\u00e7in RITOKS\u2019a bak\u0131n\u0131z <a href=\"https:\/\/ritoks.com\/tr\/product-category\/dc-power-protection\/dc-circuit-breakers\/\">DC Devre Kesiciler<\/a> kategori.<\/p>\n\n\n\n<figure data-spectra-id=\"spectra-089e2823-2cd8-429a-9b2f-89098f77dfcc\" class=\"wp-block-image size-full has-custom-border\" ><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/dc-breaker-product-family-comparison.jpg\" alt=\"Bir g\u00fcne\u015f enerjisi elektrik \u00e7al\u0131\u015fma tezgah\u0131nda yer alan temsili DC kesici \u00fcr\u00fcn gruplar\u0131\" class=\"wp-image-677\" width=\"1672\" height=\"941\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/dc-breaker-product-family-comparison.jpg 1672w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/dc-breaker-product-family-comparison-600x338.jpg 600w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/dc-breaker-product-family-comparison-300x169.jpg 300w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/dc-breaker-product-family-comparison-1024x576.jpg 1024w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/dc-breaker-product-family-comparison-768x432.jpg 768w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/dc-breaker-product-family-comparison-1536x864.jpg 1536w\" sizes=\"auto, (max-width: 1672px) 100vw, 1672px\" \/><figcaption class=\"wp-element-caption\">Mevcut DC kesici \u00fcr\u00fcn ailelerinin temsili bir g\u00f6r\u00fcn\u00fcm\u00fc; yaln\u0131zca se\u00e7im s\u00fcrecinde g\u00f6rsel bir yard\u0131mc\u0131 olarak kullan\u0131lmaktad\u0131r.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"what-is-a-dc-mcb\">DC MCB Nedir?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Bir DC minyat\u00fcr devre kesici (MCB), genellikle DIN ray\u0131 konfig\u00fcrasyonlar\u0131nda sunulan kompakt bir devre koruma cihaz\u0131d\u0131r.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">RITOKS DC MCB \u00fcr\u00fcn yelpazesi, tek bir nominal aral\u0131k yerine birka\u00e7 farkl\u0131 \u00fcr\u00fcn grubunu i\u00e7ermektedir.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u00d6rne\u011fin:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/ritoks.com\/tr\/products\/2p-dc-miniature-circuit-breaker-500-1000v-6-63a\/\">RTS-DC63-1000<\/a> \u2014 2P, 500\u20131000 V DC, 6\u201363 A, 35 mm DIN ray\u0131<\/li>\n\n\n<li>RTS-DC63-500 \u2014 2 kutuplu, 500 V DC, 6\u201363 A, 35 mm DIN ray\u0131<\/li>\n\n\n<li><a href=\"https:\/\/ritoks.com\/tr\/products\/high-current-dc-miniature-circuit-breaker-12-125v-63-250a\/\">RTS-DC250-125<\/a> \u2014 1P\/2P, 12\u2013125 V DC, 63\u2013250 A, 35 mm DIN ray\u0131<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Bu \u00f6rnekler \u00f6nemli bir se\u00e7im ilkesini ortaya koymaktad\u0131r:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u201cMCB\u201d, bir \u00fcr\u00fcn\u00fcn yap\u0131s\u0131n\u0131 ve \u00fcr\u00fcn ailesinin format\u0131n\u0131 tan\u0131mlar; bu kavram, tek bir ak\u0131m s\u0131n\u0131r\u0131yla s\u0131n\u0131rland\u0131r\u0131lmamal\u0131d\u0131r.<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Mevcut modelin, ger\u00e7ek DC sistemi ile kar\u015f\u0131la\u015ft\u0131r\u0131larak kontrol edilmesi gerekmektedir.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Daha fazla se\u00e7enek i\u00e7in bkz. <a href=\"https:\/\/ritoks.com\/tr\/product-category\/dc-power-protection\/dc-circuit-breakers\/dc-miniature-circuit-breakers\/\">DC Minyat\u00fcr Devre Kesiciler<\/a>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"what-is-a-dc-mccb\">DC MCCB Nedir?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Bir DC kal\u0131pl\u0131 g\u00f6vdeli devre kesici (MCCB), kal\u0131pl\u0131 g\u00f6vde yap\u0131s\u0131na sahiptir ve genellikle DIN ray\u0131 tipi minyat\u00fcr devre kesiciden farkl\u0131 bir \u015fekilde monte edilir.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u015eu anda piyasada bulunan RITOKS MCCB serisi \u015funlard\u0131r:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/ritoks.com\/tr\/products\/2p-dc-molded-case-circuit-breaker-500-1000v-125-250a\/\"><strong>RTS-DCM250-1000<\/strong><\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Onaylanm\u0131\u015f ve yay\u0131nlanm\u0131\u015f \u00f6zellikler \u015funlard\u0131r:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>2P yap\u0131land\u0131rmas\u0131<\/li>\n\n\n<li>500 V \/ 1000 V DC modelleri<\/li>\n\n\n<li>125A \/ 250A \u015fasiler<\/li>\n\n\n<li>panel \/ sabit montaj<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Bu, mevcut RITOKS DIN ray\u0131 tipi MCB serilerinden farkl\u0131 bir montaj bi\u00e7imi sunar.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ancak, mevcut \u00fcr\u00fcn yelpazesi RTS-DC250-125 MCB serisiyle \u00e7ak\u0131\u015fmaktad\u0131r. Bu nedenle \u015fu soruyu sormak yeterlidir:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u201cAk\u0131m belirli bir de\u011ferin \u00fczerinde mi?\u201d<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">MCB ile MCCB aras\u0131nda se\u00e7im yapmak i\u00e7in bu yeterli de\u011fildir.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Mevcut kal\u0131pl\u0131 kasa serisi i\u00e7in bkz. <a href=\"https:\/\/ritoks.com\/tr\/product-category\/dc-power-protection\/dc-circuit-breakers\/dc-molded-case-circuit-breakers\/\">DC Kal\u0131pl\u0131 Muhafazal\u0131 Devre Kesiciler<\/a>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"why-current-alone-is-not-enough\">MCB ve MCCB: Neden Sadece Ak\u0131m Yeterli De\u011fildir?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Yayg\u0131n bir se\u00e7im kural\u0131, belirli bir ak\u0131m de\u011ferinin alt\u0131ndaki devrelerde her zaman MCB\u2019lerin, \u00fcst\u00fcndeki devrelerde ise MCCB\u2019lerin kullan\u0131ld\u0131\u011f\u0131n\u0131 varsaymakt\u0131r.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Mevcut RITOKS \u00fcr\u00fcn yelpazesi, bu yakla\u015f\u0131m\u0131n neden g\u00fcvenilmez oldu\u011funu ortaya koymaktad\u0131r.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">RTS-DC250-125 MCB, 63 A ile 250 A aras\u0131nda belirtilen ak\u0131m se\u00e7eneklerine sahip 35 mm DIN ray\u0131 serisidir.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">RTS-DCM250-1000 MCCB, 125 A ve 250 A'l\u0131k g\u00f6vdelere sahiptir.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Bu aral\u0131klar birbiriyle \u00f6rt\u00fc\u015f\u00fcyor.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Dolay\u0131s\u0131yla:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>125 A veya 250 A gereksinimi, do\u011fru \u00fcr\u00fcn tipinin MCB mi yoksa MCCB mi oldu\u011funu otomatik olarak belirtmez.<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Bunun yerine, karar verilirken sistemin tamam\u0131 ve kurulum gereklilikleri dikkate al\u0131nmal\u0131d\u0131r.<\/p>\n\n\n\n<figure data-spectra-id=\"spectra-b54abfcb-0f41-4076-b6a7-51114bd5341e\" class=\"wp-block-image size-full has-custom-border\" ><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/dc-mcb-mccb-form-factor-comparison.jpg\" alt=\"G\u00fcne\u015f enerjisi DC da\u011f\u0131t\u0131m kabininde DIN ray\u0131 tipi DC MCB ile kal\u0131pl\u0131 g\u00f6vdeli DC MCCB kar\u015f\u0131la\u015ft\u0131rmas\u0131\" class=\"wp-image-676\" width=\"1672\" height=\"941\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/dc-mcb-mccb-form-factor-comparison.jpg 1672w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/dc-mcb-mccb-form-factor-comparison-600x338.jpg 600w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/dc-mcb-mccb-form-factor-comparison-300x169.jpg 300w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/dc-mcb-mccb-form-factor-comparison-1024x576.jpg 1024w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/dc-mcb-mccb-form-factor-comparison-768x432.jpg 768w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/dc-mcb-mccb-form-factor-comparison-1536x864.jpg 1536w\" sizes=\"auto, (max-width: 1672px) 100vw, 1672px\" \/><figcaption class=\"wp-element-caption\">Bir DC da\u011f\u0131t\u0131m dolab\u0131nda DIN ray\u0131 tipi DC MCB ile kal\u0131pl\u0131 g\u00f6vdeli DC MCCB kurulum bi\u00e7imlerinin a\u00e7\u0131klay\u0131c\u0131 kar\u015f\u0131la\u015ft\u0131rmas\u0131.<\/figcaption><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">1. DC sistem gerilimiyle ba\u015flay\u0131n<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u0130lk soru \u015fudur:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Kesici hangi DC gerilimini ta\u015f\u0131yabilmelidir?<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Mevcut RITOKS MCB serileri, \u00e7ok farkl\u0131 gerilim aral\u0131klar\u0131n\u0131 kapsamaktad\u0131r.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u00d6rne\u011fin:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>bir seri, 12\u2013125 V DC i\u00e7in piyasaya sunulmu\u015ftur<\/li>\n\n\n<li>500 V DC i\u00e7in bir tane daha<\/li>\n\n\n<li>500\u20131000 V DC i\u00e7in bir tane daha<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Mevcut MCCB serisi, 500 V ve 1000 V DC modelleri de i\u00e7ermektedir.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Bu, benzer ak\u0131m de\u011ferlerine sahip iki kesicinin yine de birbirinden \u00e7ok farkl\u0131 sistem gerilimi uygulamalar\u0131na ait olabilece\u011fi anlam\u0131na gelir.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Sadece ak\u0131m de\u011ferine g\u00f6re bir devre kesici se\u00e7ip, gerilim gereksiniminin de kar\u015f\u0131lanaca\u011f\u0131n\u0131 varsaymay\u0131n.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Tam model ve konfig\u00fcrasyonun kontrol edilmesi gerekir.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">2. Gerekli \u00c7al\u0131\u015fma Ak\u0131m\u0131n\u0131 Do\u011frulay\u0131n<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Ak\u0131m, h\u00e2l\u00e2 \u00f6nemli bir se\u00e7im fakt\u00f6r\u00fc olmakla birlikte, karar\u0131n yaln\u0131zca bir par\u00e7as\u0131n\u0131 olu\u015fturmaktad\u0131r.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u00d6rne\u011fin, mevcut RITOKS MCB serileri \u015funlard\u0131r:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>6\u201363A se\u00e7enekleri<\/li>\n\n\n<li>63\u2013250 A se\u00e7enekleri<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Mevcut MCCB serisi ise \u015funlar\u0131 i\u00e7ermektedir:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>125A \u015fasi<\/li>\n\n\n<li>250A \u015fasi<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Bu \u00f6rt\u00fc\u015fme, mevcut de\u011ferin aday \u00fcr\u00fcn yelpazesini daraltt\u0131\u011f\u0131 anlam\u0131na gelir; ancak bu de\u011fer tek ba\u015f\u0131na kesicinin yap\u0131s\u0131n\u0131 belirlemez.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Do\u011fru se\u00e7im, her zaman ilgili modelin belgelerine uygun olmal\u0131d\u0131r.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">3. Kutuplar\u0131n Say\u0131s\u0131n\u0131 Kontrol Edin<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Direk konfig\u00fcrasyonu da hangi \u00fcr\u00fcn grubunun uygun olaca\u011f\u0131n\u0131 etkileyebilir.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u015eu anda yay\u0131nlanm\u0131\u015f RITOKS \u00f6rnekleri aras\u0131nda \u015funlar yer almaktad\u0131r:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>2P MCB serileri<\/li>\n\n\n<li>1P\/2P d\u00fc\u015f\u00fck gerilim, y\u00fcksek ak\u0131m MCB serisi<\/li>\n\n\n<li>2P MCCB serisi<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Bu nedenle, bir model se\u00e7ilmeden \u00f6nce gerekli kutup say\u0131s\u0131 belirlenmelidir.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Her MCB veya MCCB serisinin ayn\u0131 kutuplu konfig\u00fcrasyonda sunuldu\u011funu varsaymay\u0131n.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">4. Montaj bi\u00e7imini g\u00f6z \u00f6n\u00fcnde bulundurun<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Bu, mevcut RITOKS \u00fcr\u00fcn yelpazesindeki en belirgin pratik farkl\u0131l\u0131klardan biridir.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Mevcut DC MCB Serileri<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Yay\u0131nlanan MCB \u00f6rneklerinde \u015funlar kullan\u0131lmaktad\u0131r:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>35 mm DIN ray\u0131 montaj\u0131<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Bu format genellikle uygun elektrik dolaplar\u0131 i\u00e7ine yap\u0131lan kompakt mod\u00fcler kurulumlarla ili\u015fkilendirilir.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">G\u00fcncel DC MCCB Serisi<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Yay\u0131nlanan MCCB \u00f6rne\u011finde \u015funlar kullan\u0131lmaktad\u0131r:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>panel \/ sabit montaj<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Bu, temelde farkl\u0131 bir kurulum bi\u00e7imi ortaya \u00e7\u0131kar\u0131r.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u00d6yleyse, bir projede halihaz\u0131rda \u015funlar belirtilmi\u015fse:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>DIN ray\u0131 mod\u00fcler ekipman<\/li>\n\n\n<li>panele monte edilmi\u015f kal\u0131planm\u0131\u015f g\u00f6vdeli ekipman<\/li>\n\n\n<li>belirli bir muhafaza d\u00fczeni<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Fiziksel montaj gereksinimi, se\u00e7enekleri an\u0131nda daraltabilir.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Bu, genellikle evrensel bir ak\u0131m b\u00f6lme \u00e7izgisi belirlemeye \u00e7al\u0131\u015fmaktan daha yararl\u0131d\u0131r.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">5. \u00dcr\u00fcn\u00fcn Tam Konfig\u00fcrasyonunu Kar\u015f\u0131la\u015ft\u0131r\u0131n<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u201cMCB\u201d ve \u201cMCCB\u201d, \u00fcr\u00fcn serisi tan\u0131mlamalar\u0131d\u0131r.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Belirli bir kesicinin t\u00fcm \u00f6zelliklerini size a\u00e7\u0131klam\u0131yorlar.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Sipari\u015f vermeden \u00f6nce, tam modelini ve ilgili yay\u0131nlanm\u0131\u015f konfig\u00fcrasyonu teyit edin.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Tedarik s\u00fcreci incelemesi, en az\u0131ndan a\u015fa\u011f\u0131daki hususlar\u0131 belirlemelidir:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>DC gerilimi<\/li>\n\n\n<li>mevcut ihtiya\u00e7<\/li>\n\n\n<li>direk d\u00fczeni<\/li>\n\n\n<li>montaj y\u00f6ntemi<\/li>\n\n\n<li>\u00fcr\u00fcn\u00fcn tam modeli<\/li>\n\n\n<li>uygulama ba\u011flam\u0131<\/li>\n\n\n<li>gerekli olan di\u011fer belgelenmi\u015f \u00f6zellikler<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Bir parametre, model belgelerinde do\u011frulanmam\u0131\u015fsa, ayn\u0131 genel kategorideki ba\u015fka bir kesiciden yola \u00e7\u0131k\u0131larak varsay\u0131lmamal\u0131d\u0131r.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"mcb-vs-mccb-at-a-glance\">DC MCB ve MCCB\u2019nin Kar\u015f\u0131la\u015ft\u0131rmas\u0131: Bir Bak\u0131\u015fta<\/h2>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table><thead><tr><th>Soru<\/th><th>MCB De\u011ferlendirmesi<\/th><th>MCCB De\u011ferlendirmesi<\/th><\/tr><\/thead><tbody><tr><td>DIN ray\u0131 montaj\u0131 gerekli mi?<\/td><td>Mevcut RITOKS MCB serileri 35 mm\u2019lik DIN ray\u0131 kullanmaktad\u0131r<\/td><td>\u015eu anda piyasada bulunan MCCB\u2019ler panel\/sabit montaj y\u00f6ntemini kullanmaktad\u0131r<\/td><\/tr><tr><td>1P'ye ihtiyac\u0131m var m\u0131?<\/td><td>Mevcut RTS-DC250-125 serisinde mevcuttur<\/td><td>\u015eu anda piyasada bulunan MCCB serisi 2P\u2019dir<\/td><\/tr><tr><td>Ak\u0131m 63 A\u2019n\u0131n \u00fczerinde mi?<\/td><td>Mevcut RITOKS MCB serisi, 250 A\u2019ya kadar uzanmaktad\u0131r<\/td><td>Mevcut MCCB serisi ayr\u0131ca 125 A\/250 A de\u011ferlerini de i\u00e7ermektedir<\/td><\/tr><tr><td>500 V mu yoksa 1000 V DC mi gerekiyor?<\/td><td>Se\u00e7ili MCB serilerinde mevcuttur<\/td><td>Mevcut MCCB serisinde mevcuttur<\/td><\/tr><tr><td>Sadece ak\u0131ma g\u00f6re se\u00e7im yapabilir miyim?<\/td><td>Hay\u0131r<\/td><td>Hay\u0131r<\/td><\/tr><tr><td>Tam modelini do\u011frulamal\u0131 m\u0131y\u0131m?<\/td><td>Evet<\/td><td>Evet<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Buradan \u00e7\u0131kar\u0131lmas\u0131 gereken \u00f6nemli sonu\u00e7, belirli bir kesici tipinin \u201cdaha iyi\u201d oldu\u011fu de\u011fildir.\u201d<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">As\u0131l \u00f6nemli soru \u015fudur:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Bu DC sisteminin elektrik ve kurulum gereksinimlerine hangi yap\u0131 ve tam olarak hangi model uygundur?<\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u00d6rnek 1: Kompakt DIN ray\u0131 tipi DC koruma cihaz\u0131<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Bir projenin \u015fu gereksinimleri oldu\u011funu varsayal\u0131m:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>DIN ray\u0131 tipi kesici<\/li>\n\n\n<li>sabit bir do\u011fru ak\u0131m gerilimi<\/li>\n\n\n<li>mevcut model yelpazesi i\u00e7indeki bir gereksinim<\/li>\n\n\n<li>destekli direk d\u00fczeni<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Bu durumda, mevcut DC MCB serileri incelenmesi gereken ilk \u00fcr\u00fcn grubu olabilir; zira yay\u0131nlanm\u0131\u015f RITOKS MCB \u00f6rneklerinde 35 mm\u2019lik DIN ray\u0131 kullan\u0131lmaktad\u0131r.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u00d6rne\u011fin, RTS-DC63-1000 serisi \u015fu \u00f6zellikleri sunar:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>2P<\/li>\n\n\n<li>500\u20131000 V DC<\/li>\n\n\n<li>6\u201363A<\/li>\n\n\n<li>35 mm DIN ray\u0131<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Bu, s\u00f6z konusu ba\u015fl\u0131k de\u011ferlerine uyan her sistem i\u00e7in otomatik olarak uygun oldu\u011fu anlam\u0131na gelmez. Kesin uygulama ve \u00fcr\u00fcn belgelerinin yine de teyit edilmesi gerekmektedir.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u00d6rnek 2: Y\u00fcksek Ak\u0131m Gereksinimi Olan DIN Ray\u0131<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Daha y\u00fcksek ak\u0131m gereksinimi, otomatik olarak MCCB kullan\u0131lmas\u0131 gerekti\u011fi anlam\u0131na gelmez.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">RTS-DC250-125, a\u015fa\u011f\u0131daki \u00f6zelliklere sahip, piyasaya sunulmu\u015f bir DC MCB serisidir:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>1K \/ 2K<\/li>\n\n\n<li>12\u2013125 V DC<\/li>\n\n\n<li>63\u2013250 A<\/li>\n\n\n<li>35 mm DIN ray\u0131<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Bu, her y\u00fcksek ak\u0131ml\u0131 DC uygulamas\u0131n\u0131n otomatik olarak kal\u0131pl\u0131 g\u00f6vdeli kesiciye ge\u00e7mesi gerekti\u011fi d\u00fc\u015f\u00fcncesini do\u011frudan \u00e7\u00fcr\u00fcten \u00f6nemli bir \u00f6rnektir.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Sistem gerilimi ve kurulum bi\u00e7imi h\u00e2l\u00e2 \u00f6nemlidir.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u00d6rnek 3: Panele Monte Kal\u0131pl\u0131 Muhafaza Gereklili\u011fi<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Projede panel tipi veya sabit montajl\u0131 bir kal\u0131pl\u0131 g\u00f6vdeli kesici gerekliyse, RTS-DCM250-1000 serisi uygun bir se\u00e7enek haline gelir.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Yay\u0131nlanan yap\u0131land\u0131rmas\u0131 \u015funlar\u0131 i\u00e7ermektedir:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>2P<\/li>\n\n\n<li>500 V \/ 1000 V modelleri<\/li>\n\n\n<li>125A \/ 250A \u015fasiler<\/li>\n\n\n<li>panel \/ sabit montaj<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Yine, nihai karar, yaln\u0131zca \u00fcr\u00fcn ailesinin ad\u0131na de\u011fil, se\u00e7ilen tam varyanta ve teyit edilmi\u015f \u00fcr\u00fcn verilerine dayand\u0131r\u0131lmal\u0131d\u0131r.<\/p>\n\n\n\n<figure data-spectra-id=\"spectra-7c525eab-7895-402f-bf81-0eabd9a8a98b\" class=\"wp-block-image size-full has-custom-border\" ><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/dc-circuit-breaker-application-context.jpg\" alt=\"G\u00fcne\u015f PV pil depolama ve end\u00fcstriyel DC da\u011f\u0131t\u0131m sistemlerinde DC devre kesici uygulamalar\u0131\" class=\"wp-image-674\" width=\"1672\" height=\"941\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/dc-circuit-breaker-application-context.jpg 1672w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/dc-circuit-breaker-application-context-600x338.jpg 600w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/dc-circuit-breaker-application-context-300x169.jpg 300w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/dc-circuit-breaker-application-context-1024x576.jpg 1024w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/dc-circuit-breaker-application-context-768x432.jpg 768w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/dc-circuit-breaker-application-context-1536x864.jpg 1536w\" sizes=\"auto, (max-width: 1672px) 100vw, 1672px\" \/><figcaption class=\"wp-element-caption\">G\u00fcne\u015f enerjisi (PV), pil depolama ve end\u00fcstriyel DC da\u011f\u0131t\u0131m uygulamalar\u0131n\u0131 g\u00f6steren \u00f6rnek DC elektrik ortamlar\u0131.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"selection-process\">Pratik Bir DC Devre Kesici Se\u00e7im S\u00fcreci<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Daha makul bir se\u00e7im i\u015f ak\u0131\u015f\u0131 \u015fu \u015fekilde g\u00f6r\u00fcn\u00fcr:<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">1. Ad\u0131m \u2014 DC Gerilimini Belirleyin<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Modelleri kar\u015f\u0131la\u015ft\u0131rmadan \u00f6nce sistemin ger\u00e7ek voltaj\u0131n\u0131 kontrol edin.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">2. Ad\u0131m \u2014 \u00c7al\u0131\u015fma Ak\u0131m\u0131n\u0131 Belirleyin<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Mevcut \u00fcr\u00fcn gruplar\u0131n\u0131 daraltmak i\u00e7in gerekli ak\u0131m de\u011ferini kullan\u0131n.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">3. Ad\u0131m \u2014 Direk Gereksinimini Belirleyin<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Devrenin, se\u00e7ilen aileden \u015fu anda temin edilebilen bir konfig\u00fcrasyona ihtiya\u00e7 duyup duymad\u0131\u011f\u0131n\u0131 belirleyin.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">4. Ad\u0131m \u2014 Montaj Bi\u00e7imini Belirleyin<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Kurulumun a\u015fa\u011f\u0131dakiler temel al\u0131narak tasarlan\u0131p tasarlanmad\u0131\u011f\u0131n\u0131 sorun:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>35 mm DIN ray\u0131<\/li>\n\n\n<li>panel \/ sabit montaj<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">5. Ad\u0131m \u2014 Aday Modelleri Kar\u015f\u0131la\u015ft\u0131rma<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Yaln\u0131zca yay\u0131nlanm\u0131\u015f gerilim, ak\u0131m, kutup ve montaj konfig\u00fcrasyonlar\u0131 proje gereksinimlerine uyan \u00fcr\u00fcnleri kar\u015f\u0131la\u015ft\u0131r\u0131n.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">6. Ad\u0131m \u2014 Belgelerin Do\u011frulu\u011funu Kontrol Edin<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Bir modelin elektriksel \u00f6zelliklerini, aksesuarlar\u0131n\u0131 veya performans iddialar\u0131n\u0131 ba\u015fka bir modele aktarmay\u0131n\u0131z.<\/p>\n\n\n\n<figure data-spectra-id=\"spectra-bcd1be37-2037-4196-8113-b4e424df3efa\" class=\"wp-block-image size-full has-custom-border\" ><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/dc-circuit-breaker-selection-flow.jpg\" alt=\"Gerilim, ak\u0131m, kutuplar, montaj \u015fekli ve kesin model do\u011frulamas\u0131n\u0131 kullanarak DC devre kesici se\u00e7im ak\u0131\u015f \u015femas\u0131\" class=\"wp-image-673\" width=\"1672\" height=\"941\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/dc-circuit-breaker-selection-flow.jpg 1672w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/dc-circuit-breaker-selection-flow-600x338.jpg 600w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/dc-circuit-breaker-selection-flow-300x169.jpg 300w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/dc-circuit-breaker-selection-flow-1024x576.jpg 1024w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/dc-circuit-breaker-selection-flow-768x432.jpg 768w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/dc-circuit-breaker-selection-flow-1536x864.jpg 1536w\" sizes=\"auto, (max-width: 1672px) 100vw, 1672px\" \/><figcaption class=\"wp-element-caption\">Gerilim, ak\u0131m, kutuplar, montaj \u015fekli ve kesin model do\u011frulamas\u0131na dayal\u0131 pratik bir DC devre kesici se\u00e7im ak\u0131\u015f\u0131.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"common-mistakes\">MCB ve MCCB Se\u00e7iminde S\u0131k Yap\u0131lan Hatalar<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Sabit Ak\u0131m E\u015fi\u011fi Kullan\u0131m\u0131<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Bu, ka\u00e7\u0131n\u0131lmas\u0131 gereken en \u00f6nemli hatad\u0131r.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Mevcut RITOKS \u00fcr\u00fcn yelpazesinde, ak\u0131m de\u011ferleri birbiriyle \u00f6rt\u00fc\u015fen MCB ve MCCB \u00fcr\u00fcnleri halihaz\u0131rda bulunmaktad\u0131r.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">DC Gerilimini G\u00f6z Ard\u0131 Etmek<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Ak\u0131m gereksinimine uyan bir kesici, yine de yanl\u0131\u015f gerilim grubuna ait olabilir.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Takma Bi\u00e7imini G\u00f6z Ard\u0131 Etme<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">DIN ray\u0131 \u00fczerine monte edilen bir MCB ile panele monte edilen bir MCCB, farkl\u0131 fiziksel kurulum y\u00f6ntemleri gerektirir.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Her ailenin ayn\u0131 kutuplara sahip oldu\u011funu varsayarsak<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Mevcut yap\u0131land\u0131rmalar, \u00fcr\u00fcn grubuna g\u00f6re farkl\u0131l\u0131k g\u00f6stermektedir.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Do\u011frulanmam\u0131\u015f Son Dakika Kapasitesini Varsaymak<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Kesme kapasitesi verileri, kesin olarak teyit edilmi\u015f modele veya varyant\u0131na ba\u011fl\u0131 kalmal\u0131d\u0131r. Bu veriler, MCB ve MCCB serileri genelinde genelle\u015ftirilmemelidir.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Seyahat \u0130\u015flevleri veya Aksesuarlar\u0131 Varsay\u0131m\u0131<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Sat\u0131n al\u0131nacak kesicinin tam modeli i\u00e7in a\u00e7\u0131k\u00e7a onaylanmad\u0131k\u00e7a, ayarlanabilir a\u00e7ma de\u011ferleri, a\u00e7ma e\u011frileri, \u015f\u00f6nt a\u00e7ma i\u015flevleri veya aksesuarlar\u0131n mevcut oldu\u011funu varsaymay\u0131n\u0131z.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Yaln\u0131zca G\u00f6r\u00fcn\u00fc\u015fe G\u00f6re Se\u00e7im Yapmak<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Bir kesicinin fiziksel g\u00f6r\u00fcn\u00fc\u015f\u00fc, belirli bir do\u011fru ak\u0131m devresine uygunlu\u011funu belirlemez.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">MCB ve MCCB\u2019nin Do\u011fru Ak\u0131m Korumas\u0131 \u0130\u00e7indeki Yeri<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Devre kesiciler, daha kapsaml\u0131 bir DC koruma sisteminin yaln\u0131zca bir par\u00e7as\u0131d\u0131r.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Sistem tasar\u0131m\u0131na ba\u011fl\u0131 olarak, di\u011fer i\u015flevler aras\u0131nda \u015funlar yer alabilir:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/ritoks.com\/tr\/dc-fuse-vs-dc-circuit-breaker\/\">sigorta korumas\u0131<\/a><\/li>\n\n\n<li>manuel izolasyon<\/li>\n\n\n<li>a\u015f\u0131r\u0131 gerilim korumas\u0131<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Bu i\u015flevlerin birbirinden nas\u0131l farkl\u0131 oldu\u011funa dair genel bir bak\u0131\u015f i\u00e7in bkz.:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/ritoks.com\/tr\/dc-protection-devices-explained\/\"><strong>DC Koruma Cihazlar\u0131 Hakk\u0131nda Bilgi: Devre Kesiciler, Sigortalar, \u0130zolat\u00f6rler ve SPD\u2019ler<\/strong><\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Bu k\u0131lavuzda, bir \u015falter, sigorta, izolat\u00f6r ve SPD\u2019nin neden otomatik olarak birbirinin yerine kullan\u0131labilir cihazlar olarak de\u011ferlendirilmemesi gerekti\u011fi a\u00e7\u0131klanmaktad\u0131r.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"frequently-asked-questions\">S\u0131k Sorulan Sorular<\/h2>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>MCCB, her zaman MCB\u2019den daha y\u00fcksek ak\u0131mlar i\u00e7in mi kullan\u0131l\u0131r?<\/summary>\n<p class=\"wp-block-paragraph\">Hay\u0131r. Mevcut RITOKS \u00fcr\u00fcn yelpazesi, 63 A ile 250 A aras\u0131nda nominal ak\u0131m de\u011ferlerine sahip bir DIN ray\u0131 tipi DC MCB serisi ile 125 A ve 250 A g\u00f6vde boyutlar\u0131na sahip bir DC MCCB serisini i\u00e7ermektedir. Bu serilerin ak\u0131m aral\u0131klar\u0131 birbiriyle \u00f6rt\u00fc\u015fmektedir; dolay\u0131s\u0131yla se\u00e7im, yaln\u0131zca ak\u0131m de\u011ferine g\u00f6re belirlenmez.<\/p>\n<\/details>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Mevcut RITOKS MCB ve MCCB serileri aras\u0131ndaki en belirgin fark nedir?<\/summary>\n<p class=\"wp-block-paragraph\">Onaylanm\u0131\u015f en belirgin fark, montaj bi\u00e7imidir. Mevcut RITOKS MCB modelleri 35 mm DIN ray\u0131 kullan\u0131rken, piyasaya s\u00fcr\u00fclen MCCB serisi panel\/sabit montaj kullanmaktad\u0131r.<\/p>\n<\/details>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Sadece gerilime g\u00f6re MCB ve MCCB aras\u0131nda se\u00e7im yapabilir miyim?<\/summary>\n<p class=\"wp-block-paragraph\">Hay\u0131r. Gerilim, se\u00e7im kriterlerinden sadece biridir. Ak\u0131m, kutuplar, montaj \u015fekli, modelin tam konfig\u00fcrasyonu ve uygulama gereksinimleri de kontrol edilmelidir.<\/p>\n<\/details>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>250 A\u2019l\u0131k bir DC devresinde otomatik olarak bir MCCB kullan\u0131lmas\u0131 gerekir mi?<\/summary>\n<p class=\"wp-block-paragraph\">Otomatik olarak de\u011fil. RITOKS \u015fu anda 250A\u2019ya kadar \u00e7\u0131kan bir DC MCB serisinin yan\u0131 s\u0131ra 250A g\u00f6vdeli bir MCCB serisi de piyasaya sunmaktad\u0131r. Do\u011fru se\u00e7im, elektriksel ve kurulum gereksinimlerinin tamam\u0131na ba\u011fl\u0131d\u0131r.<\/p>\n<\/details>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>T\u00fcm DC MCB\u2019ler Ayn\u0131 Uygulamalar \u0130\u00e7in Uygun mudur?<\/summary>\n<p class=\"wp-block-paragraph\">Hay\u0131r. \u015eu anda piyasada bulunan MCB serileri, farkl\u0131 gerilim, ak\u0131m ve kutuplu yap\u0131land\u0131rmalara sahiptir. Uygunluk, ilgili model i\u00e7in teyit edilmelidir.<\/p>\n<\/details>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Kesici Se\u00e7erken Kesme Kapasitesi Kar\u015f\u0131la\u015ft\u0131r\u0131lmal\u0131 m\u0131?<\/summary>\n<p class=\"wp-block-paragraph\">Bu, \u00f6nemli bir \u00fcr\u00fcn \u00f6zelli\u011fi olabilir; ancak bu de\u011fer, ilgili model veya varyant i\u00e7in do\u011frulanm\u0131\u015f belgelere dayanmal\u0131d\u0131r. Bir \u00fcr\u00fcn\u00fcn de\u011ferini t\u00fcm MCB veya MCCB ailesine genelle\u015ftirmeyin.<\/p>\n<\/details>\n\n\n\n<div class=\"wp-block-group has-ast-global-color-5-color has-ast-global-color-2-background-color has-text-color has-background is-layout-constrained wp-container-core-group-is-layout-737f6912 wp-block-group-is-layout-constrained\" style=\"border-radius:6px;margin-top:48px;padding-top:40px;padding-right:32px;padding-bottom:40px;padding-left:32px\">\n<h2 class=\"wp-block-heading\">DC MCB veya MCCB Se\u00e7erken Yard\u0131ma m\u0131 \u0130htiyac\u0131n\u0131z Var?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">RITOKS, hem DC minyat\u00fcr devre kesici hem de DC kal\u0131pl\u0131 g\u00f6vdeli devre kesici \u00fcr\u00fcn gruplar\u0131n\u0131 sunmaktad\u0131r.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Tedarik talebiniz i\u00e7in l\u00fctfen a\u015fa\u011f\u0131daki bilgileri sa\u011flay\u0131n\u0131z:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>DC sistem gerilimi<\/li>\n\n\n<li>\u00e7al\u0131\u015fma ak\u0131m\u0131<\/li>\n\n\n<li>gerekli direkler<\/li>\n\n\n<li>tercih edilen kurulum bi\u00e7imi<\/li>\n\n\n<li>ba\u015fvuru<\/li>\n\n\n<li>gerekli olan her t\u00fcrl\u00fc belgelenmi\u015f \u00f6zellik<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">RITOKS, daha sonra bu talebi mevcut \u00fcr\u00fcn gruplar\u0131 ve teyit edilmi\u015f model bilgileriyle e\u015fle\u015ftirebilir.<\/p>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-ast-global-color-0-background-color has-background wp-element-button\" href=\"https:\/\/ritoks.com\/tr\/product-category\/dc-power-protection\/dc-circuit-breakers\/\">DC Devre Kesicilerini G\u00f6r\u00fcnt\u00fcle \u2192<\/a><\/div>\n\n\n\n<div class=\"wp-block-button is-style-outline is-style-outline--1\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/ritoks.com\/tr\/contact-us\/\">RITOKS ile \u0130leti\u015fime Ge\u00e7in \u2192 Fiyat Teklifi \u0130steyin<\/a><\/div>\n<\/div>\n<\/div>\n\n\n<\/div>","protected":false},"excerpt":{"rendered":"<p>How to Choose a DC Circuit Breaker: MCB vs MCCB Choosing between a DC miniature circuit breaker (MCB) and a [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"no-sidebar","site-content-layout":"page-builder","ast-site-content-layout":"full-width-container","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"disabled","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"disabled","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"disabled","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ritoks_resource_detail_renderer":null,"ritoks_resource_product_cat_term_id":0,"footnotes":""},"categories":[64],"tags":[],"class_list":["post-668","post","type-post","status-publish","format-standard","hentry","category-circuit-protection"],"acf":[],"spectra_blocks_featured_image_url":null,"spectra_blocks_author_info":{"display_name":"RITOKS","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/6d7d0fc73468198f994ab13ef6eb6558c53b6ed1ad86364d5165efe8bdf8eb4a?s=96&d=mm&r=g","author_link":"https:\/\/ritoks.com\/tr\/author\/dazzlingwqbgmail-com\/","description":""},"_links":{"self":[{"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/posts\/668","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/comments?post=668"}],"version-history":[{"count":7,"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/posts\/668\/revisions"}],"predecessor-version":[{"id":1450,"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/posts\/668\/revisions\/1450"}],"wp:attachment":[{"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/media?parent=668"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/categories?post=668"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/tags?post=668"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}