{"id":706,"date":"2026-09-06T01:11:26","date_gmt":"2026-09-06T01:11:26","guid":{"rendered":"https:\/\/ritoks.com\/?p=706"},"modified":"2026-10-01T09:19:46","modified_gmt":"2026-10-01T09:19:46","slug":"6ka-vs-10ka-mcb-breaking-capacity","status":"publish","type":"post","link":"https:\/\/ritoks.com\/tr\/6ka-vs-10ka-mcb-breaking-capacity\/","title":{"rendered":"6 kA ve 10 kA MCB: Kesme Kapasitesi De\u011ferlerini Anlamak"},"content":{"rendered":"<div class=\"wp-block-group alignfull has-ast-global-color-5-color has-ast-global-color-2-background-color has-text-color has-background is-layout-constrained wp-container-core-group-is-layout-a2d0cf3a wp-block-group-is-layout-constrained\" style=\"padding-top:64px;padding-right:24px;padding-bottom:64px;padding-left:24px\">\n\n<h1 class=\"wp-block-heading\">6 kA ve 10 kA MCB: Kesme Kapasitesi De\u011ferlerini Anlamak<\/h1>\n\n<figure data-spectra-id=\"spectra-8529fa45-f3c3-469f-99ac-730196e7062f\" class=\"wp-block-image aligncenter size-full has-custom-border\" ><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-industrial-workbench.jpg\" alt=\"End\u00fcstriyel bir elektrik \u00e7al\u0131\u015fma tezgah\u0131 \u00fczerinde bulunan tipik AC minyat\u00fcr devre kesiciler\" class=\"wp-image-709\"  width=\"1672\" height=\"941\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-industrial-workbench.jpg 1672w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-industrial-workbench-600x338.jpg 600w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-industrial-workbench-300x169.jpg 300w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-industrial-workbench-1024x576.jpg 1024w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-industrial-workbench-768x432.jpg 768w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/ac-mcb-industrial-workbench-1536x864.jpg 1536w\" sizes=\"auto, (max-width: 1672px) 100vw, 1672px\" \/><figcaption class=\"wp-element-caption\">End\u00fcstriyel bir elektrik \u00e7al\u0131\u015fma tezgah\u0131 ortam\u0131nda g\u00f6sterilen tipik AC MCB formatlar\u0131.<\/figcaption><\/figure>\n\n<p class=\"wp-block-paragraph\">Minyat\u00fcr devre kesicileri kar\u015f\u0131la\u015ft\u0131r\u0131rken, 6 kA ve 10 kA de\u011ferleri k\u0131sa devre kesme kapasitesi de\u011ferlerini ifade eder.<\/p>\n\n<p class=\"wp-block-paragraph\">Bu de\u011ferler, kesicinin normal ak\u0131m de\u011ferini, kutup d\u00fczenini veya a\u00e7ma e\u011frisini belirtmez.<\/p>\n<\/div>\n\n\n<div class=\"wp-block-group alignfull is-layout-constrained wp-container-core-group-is-layout-105ba9aa wp-block-group-is-layout-constrained\" style=\"padding-top:64px;padding-right:24px;padding-bottom:64px;padding-left:24px\">\n\n<p class=\"wp-block-paragraph\">6 kA\u2019l\u0131k bir kesici ile 10 kA\u2019l\u0131k bir kesici, her ikisi de 32 A nominal ak\u0131ma sahip olabilir, ayn\u0131 kutuplu d\u00fczeni kullanabilir ve ayn\u0131 B veya C a\u00e7ma karakteristi\u011fine sahip olabilir. Aradaki fark, ilgili standart ve belirtilen ko\u015fullar alt\u0131nda kesicinin kesme kapasitesine sahip oldu\u011fu olas\u0131 k\u0131sa devre ak\u0131m\u0131 seviyesidir.<\/p>\n\n<p class=\"wp-block-paragraph\">En \u00f6nemli nokta \u015fudur:<\/p>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>10 kA, e\u015fde\u011fer derecelendirme ko\u015fullar\u0131 alt\u0131nda 6 kA\u2019dan daha y\u00fcksek bir kesme kapasitesi de\u011feridir; ancak bu, 10 kA\u2019n\u0131n her kurulum i\u00e7in otomatik olarak do\u011fru se\u00e7im oldu\u011fu anlam\u0131na gelmez.<\/strong><\/p>\n<\/blockquote>\n\n<p class=\"wp-block-paragraph\">Gerekli kesme kapasitesi, kesicinin kurulaca\u011f\u0131 noktadaki \u00f6ng\u00f6r\u00fclen k\u0131sa devre ak\u0131m\u0131 dikkate al\u0131narak belirlenmelidir. <a href=\"https:\/\/assets.sc.hager.com\/ie\/-\/media\/project\/hagerdeep\/republic-of-ireland\/hager\/republic-of-ireland\/documents\/residential-distibution-catalogue_ie.pdf?la=en-ie\" target=\"_blank\" rel=\"noopener\">Hager\u2019in IEC\/EN 60898-1 MCB\u2019leri i\u00e7in teknik k\u0131lavuzu<\/a> belirtir ki, nominal k\u0131sa devre kapasitesi (Icn), uygulama noktas\u0131ndaki olas\u0131 k\u0131sa devre ak\u0131m\u0131na e\u015fit veya bundan daha b\u00fcy\u00fck olmal\u0131d\u0131r.<\/p>\n\n<h2 id=\"in-this-guide\" class=\"wp-block-heading\">Bu K\u0131lavuzda<\/h2>\n\n<ul class=\"wp-block-list\">\n\n<li><a href=\"#quick-answer\">H\u0131zl\u0131 Cevap: 6 kA ile 10 kA MCB Kar\u015f\u0131la\u015ft\u0131rmas\u0131<\/a><\/li>\n\n\n<li><a href=\"#breaking-capacity\">MCB\u2019nin Kopma Kapasitesi Ne Anlama Gelir?<\/a><\/li>\n\n\n<li><a href=\"#prospective-current\">Beklenen K\u0131sa Devre Ak\u0131m\u0131<\/a><\/li>\n\n\n<li><a href=\"#icn-ics\">Icn, Ics ve Standartlar Ba\u011flam\u0131<\/a><\/li>\n\n\n<li><a href=\"#what-changes\">6 kA ile 10 kA Aras\u0131nda Neler De\u011fi\u015fir?<\/a><\/li>\n\n\n<li><a href=\"#ritoks-options\">Mevcut RITOKS Se\u00e7enekleri<\/a><\/li>\n\n\n<li><a href=\"#selection-process\">Do\u011frulama S\u00fcreci<\/a><\/li>\n\n\n<li><a href=\"#common-mistakes\">S\u0131k Yap\u0131lan Hatalar<\/a><\/li>\n\n\n<li><a href=\"#frequently-asked-questions\">S\u0131k Sorulan Sorular<\/a><\/li>\n\n<\/ul>\n\n<h2 id=\"quick-answer\" class=\"wp-block-heading\">H\u0131zl\u0131 Cevap: 6 kA ile 10 kA MCB Kar\u015f\u0131la\u015ft\u0131rmas\u0131<\/h2>\n\n<figure class=\"wp-block-table is-style-stripes\"><table><thead><tr><th>De\u011ferlendirme<\/th><th>Ne Anlama Geliyor?<\/th><th>Size Anlatmad\u0131\u011f\u0131 \u015eeyler<\/th><\/tr><\/thead><tbody><tr><td>6 kA<\/td><td>Belirtilen ko\u015fullar alt\u0131nda 6 kA olarak yay\u0131nlanm\u0131\u015f bir k\u0131sa devre kesme kapasitesi de\u011feri<\/td><td>Normal ak\u0131m de\u011feri, devre kesme e\u011frisi, kutup say\u0131s\u0131 veya otomatik uygulamaya uygunluk<\/td><\/tr><tr><td>10 kA<\/td><td>E\u015fde\u011fer ko\u015fullar alt\u0131nda 10 kA\u2019l\u0131k daha y\u00fcksek bir k\u0131sa devre kesme kapasitesi de\u011feri<\/td><td>Kesicinin her proje i\u00e7in genel olarak daha g\u00fcvenli, daha iyi ya da zorunlu oldu\u011fu<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p class=\"wp-block-paragraph\">Bu kar\u015f\u0131la\u015ft\u0131rma, ilgili standart, gerilim, kesicinin tam modeli ve nominal de\u011fer bilgisi de bilindi\u011finde anlaml\u0131 olur.<\/p>\n\n<p class=\"wp-block-paragraph\">Tek bir kA de\u011feri, kesicinin t\u00fcm teknik \u00f6zellikleri olarak de\u011ferlendirilmemelidir.<\/p>\n\n<h2 id=\"breaking-capacity\" class=\"wp-block-heading\">MCB'nin Kopma Kapasitesi Ne Anlama Gelir?<\/h2>\n\n<p class=\"wp-block-paragraph\">Bir k\u0131sa devre, bir devrenin normal \u00e7al\u0131\u015fma ak\u0131m\u0131n\u0131n \u00e7ok \u00fczerinde bir ak\u0131m olu\u015fturabilir.<\/p>\n\n<p class=\"wp-block-paragraph\">Bu nedenle bir MCB, s\u0131radan a\u015f\u0131r\u0131 y\u00fck durumlar\u0131na kar\u015f\u0131 koruma sa\u011flamaktan daha fazlas\u0131n\u0131 yapmal\u0131d\u0131r. Ayr\u0131ca, tasarland\u0131\u011f\u0131 ve test edildi\u011fi s\u0131n\u0131rlar dahilinde bir k\u0131sa devre ak\u0131m\u0131n\u0131 kesebilmelidir.<\/p>\n\n<p class=\"wp-block-paragraph\">IEC\/EN 60898-1 standard\u0131na uygun minyat\u00fcr devre kesiciler i\u00e7in, <a href=\"https:\/\/library.e.abb.com\/public\/4009e91864554accb8c325cb552f18e0\/9AKK108468A3912_en_9AKK108468A3912_B01_D_B01%20Electrical%20installation%20solutions%20for%20buildings_part%20B01%20MCBs%20_EN_%20%28PDF%29.pdf\" target=\"_blank\" rel=\"noopener\">ABB\u2019nin minyat\u00fcr devre kesicilerle ilgili teknik detaylar\u0131<\/a> Icn de\u011ferini, \u00fcreticinin belirlenen bir test dizisine g\u00f6re kesiciye atad\u0131\u011f\u0131 nominal k\u0131sa devre kapasitesi olarak tan\u0131mlar. Bu de\u011fer, olas\u0131 k\u0131sa devre ak\u0131m\u0131yla ilgilidir.<\/p>\n\n<p class=\"wp-block-paragraph\">\u0130\u015fte bu nedenle kopma kapasitesi, nominal ak\u0131mdan farkl\u0131d\u0131r. <strong>6 A ve 6 kA ayn\u0131 de\u011fer de\u011fildir:<\/strong> 6A, nominal ak\u0131m de\u011feridir; 6kA (6.000A) ise belirtilen nominal ko\u015fullar alt\u0131nda k\u0131sa devre kesme kapasitesi de\u011feridir. MCB\u2019leri kar\u015f\u0131la\u015ft\u0131r\u0131rken her iki de\u011feri de ayr\u0131 ayr\u0131 kontrol edin.<\/p>\n\n<p class=\"wp-block-paragraph\">\u00d6rne\u011fin:<\/p>\n\n<ul class=\"wp-block-list\">\n\n<li><strong>32A<\/strong> ak\u0131m de\u011ferini belirtir.<\/li>\n\n\n<li><strong>C e\u011frisi<\/strong> bir devre kesilme \u00f6zelli\u011fini a\u00e7\u0131klamaktad\u0131r.<\/li>\n\n\n<li><strong>10 kA Icn<\/strong> k\u0131sa devre kesme kapasitesini belirtir.<\/li>\n\n<\/ul>\n\n<p class=\"wp-block-paragraph\">Bunlar farkl\u0131 sorulara cevap veriyor.<\/p>\n\n<p class=\"wp-block-paragraph\">Ak\u0131m, kutuplar, kesme e\u011frisi ve kesme kapasitesini bir arada ele alan daha kapsaml\u0131 se\u00e7im s\u00fcreci i\u00e7in bkz. <a href=\"https:\/\/ritoks.com\/tr\/ac-mcb-selection-guide\/\">AC MCB Se\u00e7im K\u0131lavuzu<\/a>.<\/p>\n\n<h2 id=\"prospective-current\" class=\"wp-block-heading\">Prospektif K\u0131sa Devre Ak\u0131m\u0131 Nedir?<\/h2>\n\n<p class=\"wp-block-paragraph\">Olas\u0131 k\u0131sa devre ak\u0131m\u0131, tan\u0131mlanm\u0131\u015f ko\u015fullar alt\u0131nda bir k\u0131sa devre meydana geldi\u011finde elektrik sistemindeki belirli bir noktada akabilecek ak\u0131md\u0131r.<\/p>\n\n<p class=\"wp-block-paragraph\">Bu, sadece normal y\u00fck ak\u0131m\u0131n\u0131n uygun bir katsay\u0131yla \u00e7arp\u0131lmas\u0131 de\u011fildir.<\/p>\n\n<p class=\"wp-block-paragraph\">Mevcut ar\u0131za ak\u0131m\u0131, tesisata g\u00fc\u00e7 sa\u011flayan elektrik sistemine ba\u011fl\u0131d\u0131r; bu, kaynak \u00f6zellikleri ve devre empedans\u0131 gibi fakt\u00f6rleri de i\u00e7erir.<\/p>\n\n<p class=\"wp-block-paragraph\">Kesici se\u00e7iminde \u00f6nemli olan genel ilke, koruma cihaz\u0131n\u0131n kesme kapasitesinin, kurulum noktas\u0131nda meydana gelmesi muhtemel k\u0131sa devre ak\u0131m\u0131 i\u00e7in yeterli olmas\u0131 gerekti\u011fidir. ABB de benzer \u015fekilde, k\u0131sa devre koruma cihazlar\u0131n\u0131n, ba\u011flant\u0131 noktas\u0131nda meydana gelmesi muhtemel maksimum k\u0131sa devre ak\u0131m\u0131 g\u00f6z \u00f6n\u00fcnde bulundurularak se\u00e7ilmesi gerekti\u011fini a\u00e7\u0131klamaktad\u0131r.<\/p>\n\n<p class=\"wp-block-paragraph\">Bu makale, ar\u0131za ak\u0131m\u0131 hesaplama y\u00f6ntemi sunmamaktad\u0131r.<\/p>\n\n<p class=\"wp-block-paragraph\">Bu hesaplama, sistemin elektriksel tasar\u0131m\u0131n\u0131n bir par\u00e7as\u0131d\u0131r.<\/p>\n\n<h2 id=\"no-building-mapping\" class=\"wp-block-heading\">Neden Y\u00fck Ad\u0131ndan Tek Ba\u015f\u0131na 6 kA ve 10 kA Se\u00e7ilemez?<\/h2>\n\n<p class=\"wp-block-paragraph\">A\u015fa\u011f\u0131daki gibi k\u0131sayollar\u0131 kullanmak cazip gelebilir:<\/p>\n\n<ul class=\"wp-block-list\">\n\n<li>Konutlar i\u00e7in 6 kA<\/li>\n\n\n<li>Ticari kullan\u0131m i\u00e7in 10 kA<\/li>\n\n\n<li>End\u00fcstriyel kullan\u0131m i\u00e7in 10 kA<\/li>\n\n<\/ul>\n\n<p class=\"wp-block-paragraph\">Bu ifadeler, g\u00fcvenilir se\u00e7im kurallar\u0131 olamayacak kadar genel niteliktedir.<\/p>\n\n<p class=\"wp-block-paragraph\">Gerekli kesme kapasitesi, tesisat noktas\u0131ndaki olas\u0131 ar\u0131za ko\u015fullar\u0131ndan ve ge\u00e7erli proje gerekliliklerinden kaynaklan\u0131r; bu, binan\u0131n konut, ticari veya end\u00fcstriyel olarak s\u0131n\u0131fland\u0131r\u0131lmas\u0131na ba\u011fl\u0131 de\u011fildir.<\/p>\n\n<p class=\"wp-block-paragraph\">Benzer y\u00fcklere sahip iki tesis, besleme sistemlerinin farkl\u0131 olmas\u0131 nedeniyle farkl\u0131 olas\u0131 k\u0131sa devre ak\u0131mlar\u0131na sahip olabilir.<\/p>\n\n<p class=\"wp-block-paragraph\">Ayn\u0131 \u015fekilde, ayn\u0131 da\u011f\u0131t\u0131m sistemi i\u00e7indeki farkl\u0131 noktalar\u0131n ar\u0131za ak\u0131m\u0131 ko\u015fullar\u0131 birbiriyle ayn\u0131 olmayabilir.<\/p>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>Gerekli kA de\u011feri, yaln\u0131zca uygulama kategorisine g\u00f6re belirlenmez.<\/strong><\/p>\n<\/blockquote>\n\n<h2 id=\"icn-ics\" class=\"wp-block-heading\">Icn Ne Anlama Gelir?<\/h2>\n\n<p class=\"wp-block-paragraph\">IEC\/EN 60898-1 standard\u0131na tabi MCB\u2019ler i\u00e7in Icn, nominal k\u0131sa devre kapasitesini ifade eder.<\/p>\n\n<p class=\"wp-block-paragraph\">ABB, Icn de\u011ferini, standard\u0131n tan\u0131mlad\u0131\u011f\u0131 test dizisine g\u00f6re kesiciye atanan k\u0131sa devre kesme kapasitesi olarak tan\u0131mlamaktad\u0131r. Hager ise, kesicinin Icn de\u011ferinin, kullan\u0131m noktas\u0131nda beklenen k\u0131sa devre ak\u0131m\u0131na e\u015fit veya bundan daha b\u00fcy\u00fck olmas\u0131 gerekti\u011fini belirtmektedir.<\/p>\n\n<p class=\"wp-block-paragraph\">Dolay\u0131s\u0131yla, bir \u00fcr\u00fcn \u015fu \u015fekilde a\u00e7\u0131k\u00e7a yay\u0131nlanm\u0131\u015fsa:<\/p>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>10 kA Icn<\/strong><\/p>\n<\/blockquote>\n\n<p class=\"wp-block-paragraph\">Bu ifade, sadece \u015funu s\u00f6ylemekten daha nettir:<\/p>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>10 kA'l\u0131k kesici<\/strong><\/p>\n<\/blockquote>\n\n<p class=\"wp-block-paragraph\">\u00e7\u00fcnk\u00fc bu, at\u0131fta bulunulan k\u0131sa devre dayan\u0131m de\u011ferinin t\u00fcr\u00fcn\u00fc belirtir.<\/p>\n\n<p class=\"wp-block-paragraph\">Ancak, standart ve voltaj h\u00e2l\u00e2 \u00f6nemlidir.<\/p>\n\n<h2 id=\"ics\" class=\"wp-block-heading\">ICS Ne Anlama Gelir?<\/h2>\n\n<p class=\"wp-block-paragraph\">Ics, hizmet k\u0131sa devre kesme kapasitesini ifade eder.<\/p>\n\n<p class=\"wp-block-paragraph\">IEC\/EN 60898-1 standard\u0131na g\u00f6re, Icn ve Ics birbiriyle ili\u015fkili olmakla birlikte ayn\u0131 terimler de\u011fildir. ABB, standard\u0131n nominal k\u0131sa devre kapasitesi ve hizmet k\u0131sa devre kapasitesi i\u00e7in farkl\u0131, \u00f6nceden belirlenmi\u015f test dizileri kulland\u0131\u011f\u0131n\u0131 a\u00e7\u0131klamaktad\u0131r.<\/p>\n\n<p class=\"wp-block-paragraph\">\u00dcr\u00fcn verilerini incelerken bu ayr\u0131m \u00f6nemlidir.<\/p>\n\n<p class=\"wp-block-paragraph\">\u00d6rne\u011fin, RTSXD01 ve RTSXD04 i\u00e7in g\u00fcncel RITOKS verileri \u015fu \u015fekilde yay\u0131nlanmaktad\u0131r:<\/p>\n\n<ul class=\"wp-block-list\">\n\n<li>Icn: 10 kA<\/li>\n\n\n<li>Ics: 7,5 kA<\/li>\n\n<\/ul>\n\n<p class=\"wp-block-paragraph\">Bu rakamlar, yay\u0131nland\u0131klar\u0131 \u015fekliyle aynen korunmal\u0131d\u0131r.<\/p>\n\n<p class=\"wp-block-paragraph\">Bu de\u011ferlerin her ikisinin de ayn\u0131 anlama geldi\u011fi iddias\u0131yla basitle\u015ftirilmemelidir.<\/p>\n\n<p class=\"wp-block-paragraph\">Ayn\u0131 \u015fekilde, ba\u015fka bir RITOKS \u00fcr\u00fcn\u00fcnde Icn veya Ics de\u011ferleri belirtilmeden sadece 6 kA de\u011feri verilmi\u015fse, bu makalede eksik olan bu de\u011ferler uydurulmamal\u0131d\u0131r.<\/p>\n\n<h2 id=\"rating-designations\" class=\"wp-block-heading\">Icn, Ics ve Icu birbirinin yerine kullan\u0131lamaz<\/h2>\n\n<p class=\"wp-block-paragraph\">Bir ba\u015fka yayg\u0131n kafa kar\u0131\u015f\u0131kl\u0131\u011f\u0131 kayna\u011f\u0131 ise, farkl\u0131 standartlardan al\u0131nan k\u0131sa devre de\u011ferlerini sanki ayn\u0131 nominal de\u011fermi\u015f gibi kar\u015f\u0131la\u015ft\u0131rmakt\u0131r.<\/p>\n\n<p class=\"wp-block-paragraph\">IEC\/EN 60898-1 standard\u0131nda, minyat\u00fcr devre kesiciler i\u00e7in genellikle \u201cIcn\u201d terimi kullan\u0131l\u0131r.<\/p>\n\n<p class=\"wp-block-paragraph\">IEC\/EN 60947-2 standard\u0131nda, nominal nihai k\u0131sa devre kesme kapasitesi olan Icu ve nominal \u00e7al\u0131\u015fma k\u0131sa devre kesme kapasitesi olan Ics gibi terimler kullan\u0131lmaktad\u0131r.<\/p>\n\n<p class=\"wp-block-paragraph\">ABB, bu iki standard\u0131n kapsam ve tan\u0131mlar\u0131n\u0131n farkl\u0131 oldu\u011funa dikkat \u00e7ekerek, m\u00fchendislerin belirli bir tasar\u0131ma hangi k\u0131sa devre kapasitesi tan\u0131m\u0131n\u0131n uygulanaca\u011f\u0131n\u0131 belirlemeleri gerekti\u011fini belirtmektedir.<\/p>\n\n<p class=\"wp-block-paragraph\">A <a href=\"https:\/\/eshop.se.com\/sg\/miniature-circuit-breaker-mcb-acti9-ic60n-4p-20a-b-curve-6000a-iec-en-60898-1-10ka-iec-en-60947-2-a9f73420.html\" target=\"_blank\" rel=\"noopener\">Schneider Electric MCB \u00fcr\u00fcn sayfas\u0131<\/a> Bu konuda yararl\u0131 bir ger\u00e7ek hayattan \u00f6rnek sunmaktad\u0131r: Ayn\u0131 cihaz, gerilime ve standarda ba\u011fl\u0131 olarak IEC\/EN 60898-1 standard\u0131 kapsam\u0131nda 6000A Icn de\u011ferini bildirirken, ayn\u0131 zamanda IEC\/EN 60947-2 standard\u0131 kapsam\u0131nda farkl\u0131 bir kesme kapasitesi de\u011feri de bildirebilir.<\/p>\n\n<p class=\"wp-block-paragraph\">Bu, say\u0131lardan birinin yanl\u0131\u015f oldu\u011fu anlam\u0131na gelmez.<\/p>\n\n<p class=\"wp-block-paragraph\">Bu, derecelendirme ba\u011flam\u0131n\u0131n farkl\u0131 oldu\u011fu anlam\u0131na gelir.<\/p>\n\n<h2 id=\"what-changes\" class=\"wp-block-heading\">6 kA ile 10 kA: Asl\u0131nda Ne De\u011fi\u015fir?<\/h2>\n\n<p class=\"wp-block-paragraph\">\u0130ki kesici de\u011feri, di\u011fer t\u00fcm ko\u015fullar e\u015fit olmak kayd\u0131yla kar\u015f\u0131la\u015ft\u0131r\u0131ld\u0131\u011f\u0131nda, 10 kA, 6 kA\u2019ya k\u0131yasla daha y\u00fcksek bir k\u0131sa devre kesme kapasitesi de\u011ferini temsil eder.<\/p>\n\n<p class=\"wp-block-paragraph\">Pratik a\u00e7\u0131dan bak\u0131ld\u0131\u011f\u0131nda, yay\u0131nlanan de\u011fer, kesiciye belirtilen nominal ko\u015fullar alt\u0131nda daha y\u00fcksek bir k\u0131sa devre kesme kapasitesi atand\u0131\u011f\u0131n\u0131 g\u00f6sterir.<\/p>\n\n<p class=\"wp-block-paragraph\">Neler otomatik olarak de\u011fi\u015fmez?<\/p>\n\n<ul class=\"wp-block-list\">\n\n<li>daha y\u00fcksek nominal ak\u0131m de\u011feri<\/li>\n\n\n<li>daha fazla direk<\/li>\n\n\n<li>farkl\u0131 bir B\/C\/D s\u00fcr\u00fc\u015f \u00f6zelli\u011fi<\/li>\n\n\n<li>daha iyi a\u015f\u0131r\u0131 y\u00fck korumas\u0131<\/li>\n\n\n<li>daha y\u00fcksek \u00fcr\u00fcn kalitesi<\/li>\n\n\n<li>daha uzun hizmet \u00f6mr\u00fc<\/li>\n\n\n<li>daha iyi se\u00e7icilik<\/li>\n\n\n<li>belirli bir sekt\u00f6re uygunluk<\/li>\n\n<\/ul>\n\n<p class=\"wp-block-paragraph\">Bu parametreler ayr\u0131 ayr\u0131 kontrol edilmelidir.<\/p>\n\n<figure data-spectra-id=\"spectra-e7f54276-da17-4971-a2b4-8cba8e7d99d2\" class=\"wp-block-image aligncenter size-full has-custom-border\" ><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/6ka-vs-10ka-mcb-comparison.jpg\" alt=\"6 kA ve 10 kA MCB kesme kapasitesi de\u011ferlerinin kavramsal kar\u015f\u0131la\u015ft\u0131rmas\u0131\" class=\"wp-image-710\"  width=\"1672\" height=\"941\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/6ka-vs-10ka-mcb-comparison.jpg 1672w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/6ka-vs-10ka-mcb-comparison-600x338.jpg 600w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/6ka-vs-10ka-mcb-comparison-300x169.jpg 300w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/6ka-vs-10ka-mcb-comparison-1024x576.jpg 1024w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/6ka-vs-10ka-mcb-comparison-768x432.jpg 768w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/6ka-vs-10ka-mcb-comparison-1536x864.jpg 1536w\" sizes=\"auto, (max-width: 1672px) 100vw, 1672px\" \/><figcaption class=\"wp-element-caption\">6 kA ve 10 kA de\u011ferlerinin kavramsal kar\u015f\u0131la\u015ft\u0131rmas\u0131. Kesme kapasitesi, ilgili standart, gerilim ve kesin model ile birlikte kontrol edilmelidir.<\/figcaption><\/figure>\n\n<h3 class=\"wp-block-heading\">6 kA\u2019l\u0131k bir kesici \u201cd\u00fc\u015f\u00fck kaliteli\u201d de\u011fildir<\/h3>\n\n<p class=\"wp-block-paragraph\">6 kA\u2019l\u0131k bir kesici, 10 kA\u2019l\u0131k bir kesiciden otomatik olarak daha d\u00fc\u015f\u00fck kalitede de\u011fildir.<\/p>\n\n<p class=\"wp-block-paragraph\">Kurulum gereksinimleri, do\u011fru \u015fekilde belirlenen 6 kA\u2019l\u0131k bir cihaz\u0131n kar\u015f\u0131lad\u0131\u011f\u0131 bir kesme kapasitesi gerektiriyorsa, 10 kA de\u011feri tek ba\u015f\u0131na bir kalite art\u0131\u015f\u0131 olarak yorumlanmamal\u0131d\u0131r.<\/p>\n\n<p class=\"wp-block-paragraph\">kA de\u011feri, belirli bir elektriksel kapasiteyi ifade eder.<\/p>\n\n<p class=\"wp-block-paragraph\">A\u015fa\u011f\u0131dakiler gibi bir \u00fcr\u00fcn s\u0131n\u0131f\u0131 de\u011fildir:<\/p>\n\n<ul class=\"wp-block-list\">\n\n<li>standart<\/li>\n\n\n<li>premium<\/li>\n\n\n<li>profesyonel<\/li>\n\n<\/ul>\n\n<p class=\"wp-block-paragraph\">Benzer \u015fekilde, \u201cEconomic\u201d veya \u201cPro\u201d gibi pazarlama isimleri, do\u011frulanm\u0131\u015f m\u00fchendislik teknik \u00f6zelliklerinin yerine kullan\u0131lmamal\u0131d\u0131r.<\/p>\n\n<h3 class=\"wp-block-heading\">10 kA, otomatik olarak daha iyi bir se\u00e7im de\u011fildir<\/h3>\n\n<p class=\"wp-block-paragraph\">Beklenen ar\u0131za ak\u0131m\u0131 gerektirdi\u011finde, daha y\u00fcksek bir yay\u0131nlanm\u0131\u015f kopma kapasitesi de\u011feri gerekli olabilir.<\/p>\n\n<p class=\"wp-block-paragraph\">Ancak se\u00e7im \u015fu mant\u0131\u011fa g\u00f6re yap\u0131lmamal\u0131d\u0131r:<\/p>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>Daha y\u00fcksek say\u0131 = her zaman daha iyi.<\/strong><\/p>\n<\/blockquote>\n\n<p class=\"wp-block-paragraph\">M\u00fchendislikle ilgili soru ise \u015fudur:<\/p>\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>Bu kesici, hangi olas\u0131 k\u0131sa devre ak\u0131mlar\u0131n\u0131 ve ge\u00e7erli gereklilikleri g\u00fcvenli bir \u015fekilde kar\u015f\u0131lamal\u0131d\u0131r?<\/strong><\/p>\n<\/blockquote>\n\n<p class=\"wp-block-paragraph\">Bu gereksinim belirlendikten sonra, uyumlu kesici modelleri aday listesine al\u0131nabilir.<\/p>\n\n<p class=\"wp-block-paragraph\">A\u015fa\u011f\u0131dakiler de dahil olmak \u00fczere di\u011fer parametreler de h\u00e2l\u00e2 \u00f6nemlidir:<\/p>\n\n<ul class=\"wp-block-list\">\n\n<li>nominal gerilim<\/li>\n\n\n<li>mevcut<\/li>\n\n\n<li>direkler<\/li>\n\n\n<li>yol e\u011frisi<\/li>\n\n\n<li>y\u00fck s\u0131n\u0131r\u0131 belirlemesi<\/li>\n\n\n<li>ilgili standart<\/li>\n\n\n<li>montaj<\/li>\n\n\n<li>tam \u00fcr\u00fcn \u00e7e\u015fidi<\/li>\n\n<\/ul>\n\n<h2 id=\"ritoks-options\" class=\"wp-block-heading\">RITOKS\u2019un Mevcut K\u0131r\u0131lma Kapasitesi Se\u00e7enekleri<\/h2>\n\n<p class=\"wp-block-paragraph\">\u015eu anda yay\u0131nlanm\u0131\u015f olan RITOKS AC MCB verileri <a href=\"https:\/\/ritoks.com\/tr\/product-category\/ac-power-protection\/\">AC G\u00fc\u00e7 Korumas\u0131<\/a> ve <a href=\"https:\/\/ritoks.com\/tr\/product-category\/ac-power-protection\/miniature-circuit-breakers\/\">Minyat\u00fcr Devre Kesiciler (MCB)<\/a> Bu seriler, \u00e7e\u015fitli kopma mukavemeti de\u011ferlerini i\u00e7ermektedir.<\/p>\n\n<figure class=\"wp-block-table is-style-stripes\"><table><thead><tr><th>RITOKS Modeli<\/th><th>Yay\u0131nlanan K\u0131r\u0131lma Kapasitesi<\/th><th>Notlar<\/th><\/tr><\/thead><tbody><tr><td>RTSXD01<\/td><td>10 kA Icn \/ 7,5 kA Ics<\/td><td>A\u00e7\u0131k ICN ve ICS de\u011ferleri yay\u0131nland\u0131<\/td><\/tr><tr><td>RTSXD03<\/td><td>6 kA<\/td><td>Icn\/Ics kodu yay\u0131nlanmam\u0131\u015ft\u0131r<\/td><\/tr><tr><td>RTSXD02<\/td><td>6 kA<\/td><td>Icn\/Ics kodu yay\u0131nlanmam\u0131\u015ft\u0131r<\/td><\/tr><tr><td>RTSXD04<\/td><td>10 kA Icn \/ 7,5 kA Ics<\/td><td>A\u00e7\u0131k ICN ve ICS de\u011ferleri yay\u0131nland\u0131<\/td><\/tr><tr><td>RTS-ACM60<\/td><td>Tipik 6 kA<\/td><td>Kesin varyantla do\u011frulanmal\u0131d\u0131r<\/td><\/tr><tr><td>RTS-AC47<\/td><td>1 kA<\/td><td>Icn\/Ics kodu yay\u0131nlanmam\u0131\u015ft\u0131r<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p class=\"wp-block-paragraph\">Bu tablo, yaln\u0131zca yay\u0131nlanm\u0131\u015f model ailesi bilgilerini yans\u0131tmaktad\u0131r.<\/p>\n\n<p class=\"wp-block-paragraph\">Bu, a\u015fa\u011f\u0131dakileri kan\u0131tlamaz:<\/p>\n\n<ul class=\"wp-block-list\">\n\n<li>bir al\u0131c\u0131n\u0131n tesisat\u0131ndaki olas\u0131 ar\u0131za ak\u0131m\u0131<\/li>\n\n\n<li>modele \u00f6zg\u00fc bir k\u0131sa devre test raporu<\/li>\n\n\n<li>ba\u015fka bir koruma cihaz\u0131yla koordinasyon<\/li>\n\n\n<li>Tam kadrolu SCCR<\/li>\n\n\n<li>her t\u00fcrl\u00fc uygulama t\u00fcr\u00fc i\u00e7in evrensel uygunluk<\/li>\n\n<\/ul>\n\n<h3 class=\"wp-block-heading\">Hangi g\u00fcncel RITOKS modellerinde 10 kA de\u011feri belirtilmi\u015ftir?<\/h3>\n\n<p class=\"wp-block-paragraph\">Halihaz\u0131rda piyasada bulunan iki RITOKS AC MCB serisinde 10 kA Icn \/ 7,5 kA Ics de\u011ferleri a\u00e7\u0131k\u00e7a belirtilmi\u015ftir:<\/p>\n\n<p class=\"wp-block-paragraph\"><strong>RTSXD01<\/strong><\/p>\n\n<p class=\"wp-block-paragraph\">\u015eu <a href=\"https:\/\/ritoks.com\/tr\/products\/miniature-circuit-breaker-63a-10ka\/\">RTSXD01 serisi<\/a> yay\u0131nlar:<\/p>\n\n<ul class=\"wp-block-list\">\n\n<li>AC 230\/400 V<\/li>\n\n\n<li>1\u201363A<\/li>\n\n\n<li>\u00e7ok kutuplu konfig\u00fcrasyonlar<\/li>\n\n\n<li>B\/C\/D e\u011frilerinin mevcut olup olmad\u0131\u011f\u0131<\/li>\n\n\n<li>10 kA Icn<\/li>\n\n\n<li>7,5 kA Ics<\/li>\n\n<\/ul>\n\n<p class=\"wp-block-paragraph\"><strong>RTSXD04<\/strong><\/p>\n\n<p class=\"wp-block-paragraph\">\u015eu <a href=\"https:\/\/ritoks.com\/tr\/products\/miniature-circuit-breaker-63a-10ka-pro\/\">RTSXD04 ailesi<\/a> ayr\u0131ca \u015funlar\u0131 da yay\u0131nlamaktad\u0131r:<\/p>\n\n<ul class=\"wp-block-list\">\n\n<li>AC 230\/400 V<\/li>\n\n\n<li>1\u201363A<\/li>\n\n\n<li>\u00e7ok kutuplu konfig\u00fcrasyonlar<\/li>\n\n\n<li>B\/C\/D e\u011frilerinin mevcut olup olmad\u0131\u011f\u0131<\/li>\n\n\n<li>10 kA Icn<\/li>\n\n\n<li>7,5 kA Ics<\/li>\n\n<\/ul>\n\n<p class=\"wp-block-paragraph\">Bu derecelendirmelerin varl\u0131\u011f\u0131, bu modellerin yay\u0131nlanm\u0131\u015f k\u0131sa devre kapasitesi a\u00e7\u0131s\u0131ndan kar\u015f\u0131la\u015ft\u0131r\u0131lmas\u0131n\u0131 sa\u011flar.<\/p>\n\n<p class=\"wp-block-paragraph\">Bu, al\u0131c\u0131n\u0131n kurulumuna ili\u015fkin gerekli derecelendirmeyi belirlemez.<\/p>\n\n<h3 class=\"wp-block-heading\">Hangi g\u00fcncel RITOKS modellerinde 6 kA de\u011feri belirtilmi\u015ftir?<\/h3>\n\n<p class=\"wp-block-paragraph\">Mevcut sitede \u015fu de\u011ferler i\u00e7in 6 kA de\u011feri belirtilmi\u015ftir:<\/p>\n\n<p class=\"wp-block-paragraph\"><strong>RTSXD03<\/strong><\/p>\n\n<ul class=\"wp-block-list\">\n\n<li>240 V AC<\/li>\n\n\n<li>1\u201332A<\/li>\n\n\n<li>1P+N<\/li>\n\n\n<li>6 kA<\/li>\n\n<\/ul>\n\n<p class=\"wp-block-paragraph\"><strong>RTSXD02<\/strong><\/p>\n\n<p class=\"wp-block-paragraph\">\u015eu <a href=\"https:\/\/ritoks.com\/tr\/products\/1pn-miniature-circuit-breaker-32a-6ka\/\">RTSXD02 ailesi<\/a> yay\u0131nlar:<\/p>\n\n<ul class=\"wp-block-list\">\n\n<li>240 V AC<\/li>\n\n\n<li>1\u201332A<\/li>\n\n\n<li>1P+N<\/li>\n\n\n<li>6 kA<\/li>\n\n<\/ul>\n\n<p class=\"wp-block-paragraph\"><strong>RTS-ACM60<\/strong><\/p>\n\n<p class=\"wp-block-paragraph\">\u015eu <a href=\"https:\/\/ritoks.com\/tr\/products\/m60-ac-miniature-circuit-breaker-6-63a\/\">RTS-ACM60 serisi<\/a> yay\u0131nlar:<\/p>\n\n<ul class=\"wp-block-list\">\n\n<li>230\/240 V AC<\/li>\n\n\n<li>6\u201363A<\/li>\n\n\n<li>1K \/ 2K<\/li>\n\n\n<li>Tipik 6 kA<\/li>\n\n<\/ul>\n\n<p class=\"wp-block-paragraph\">RTS-ACM60 i\u00e7in bu de\u011fer, a\u00e7\u0131k\u00e7a kesin varyant do\u011frulamas\u0131na tabidir.<\/p>\n\n<p class=\"wp-block-paragraph\">Bu uyar\u0131, her t\u00fcrl\u00fc tedarik karar\u0131nda g\u00f6z \u00f6n\u00fcnde bulundurulmal\u0131d\u0131r.<\/p>\n\n<h3 class=\"wp-block-heading\">Trip Curve bu kar\u015f\u0131la\u015ft\u0131rmada hangi konuma oturuyor?<\/h3>\n\n<p class=\"wp-block-paragraph\">Hareket e\u011frisi ve frenleme kapasitesi ayr\u0131 teknik \u00f6zelliklerdir.<\/p>\n\n<p class=\"wp-block-paragraph\">\u00d6rne\u011fin, bir al\u0131c\u0131n\u0131n \u015funlara ihtiyac\u0131 olabilir:<\/p>\n\n<ul class=\"wp-block-list\">\n\n<li>C e\u011frisi<\/li>\n\n\n<li>32A<\/li>\n\n\n<li>2P<\/li>\n\n\n<li>10 kA<\/li>\n\n<\/ul>\n\n<p class=\"wp-block-paragraph\">Her bir \u00f6\u011fe farkl\u0131 bir \u015feyi tan\u0131mlamaktad\u0131r.<\/p>\n\n<p class=\"wp-block-paragraph\">B\/C\/D s\u0131n\u0131fland\u0131rmas\u0131, kesicinin a\u00e7ma karakteristi\u011fiyle ilgilidir; kA cinsinden k\u0131sa devre derecesi ise, belirtilen \u00e7al\u0131\u015fma ko\u015fullar\u0131 alt\u0131nda kesme kapasitesini ifade eder.<\/p>\n\n<p class=\"wp-block-paragraph\">Yolculuk \u00f6zelliklerine ili\u015fkin ayr\u0131nt\u0131l\u0131 bir a\u00e7\u0131klama i\u00e7in bkz. <a href=\"https:\/\/ritoks.com\/tr\/b-curve-vs-c-curve-vs-d-curve-mcb\/\">B E\u011frisi, C E\u011frisi ve D E\u011frisi MCB\u2019ler: Aralar\u0131ndaki Fark Nedir?<\/a><\/p>\n\n<p class=\"wp-block-paragraph\">A\u00e7ma e\u011frisini kopma kapasitesini belirlemek i\u00e7in, ya da kopma kapasitesini a\u00e7ma e\u011frisini belirlemek i\u00e7in kullanmay\u0131n.<\/p>\n\n<h2 id=\"selection-process\" class=\"wp-block-heading\">Daha G\u00fcvenli Bir Fren Kapasitesi Se\u00e7im S\u00fcreci<\/h2>\n\n<p class=\"wp-block-paragraph\">Teknik bir tedarik s\u00fcreci, bir ar\u0131za ak\u0131m\u0131 tasar\u0131m hesaplamas\u0131na d\u00f6n\u00fc\u015ft\u00fcr\u00fclmeden basit tutulabilir.<\/p>\n\n<h3 class=\"wp-block-heading\">1. Gerekli K\u0131sa Devre De\u011ferini Belirleyin<\/h3>\n\n<p class=\"wp-block-paragraph\">Projenin elektrik tasar\u0131m\u0131n\u0131, teknik \u00f6zelliklerini veya do\u011frulanm\u0131\u015f olas\u0131 k\u0131sa devre ak\u0131m\u0131 verilerini kullan\u0131n.<\/p>\n\n<p class=\"wp-block-paragraph\">Gerekli de\u011feri yaln\u0131zca bina t\u00fcr\u00fcne g\u00f6re tahmin etmeyin.<\/p>\n\n<h3 class=\"wp-block-heading\">2. Standart ve Derecelendirme Tan\u0131m\u0131n\u0131 Do\u011frulay\u0131n<\/h3>\n\n<p class=\"wp-block-paragraph\">Gerekli de\u011ferin \u015fu \u015fekilde belirtilip belirtilmedi\u011fini kontrol edin:<\/p>\n\n<ul class=\"wp-block-list\">\n\n<li>Icn<\/li>\n\n\n<li>Ics<\/li>\n\n\n<li>Yo\u011fun Bak\u0131m \u00dcnitesi<\/li>\n\n\n<li>ya da ba\u015fka bir ilgili k\u0131sa devre parametresi<\/li>\n\n<\/ul>\n\n<p class=\"wp-block-paragraph\">Bu terimlerin birbirinin yerine kullan\u0131labilece\u011fini varsaymay\u0131n.<\/p>\n\n<h3 class=\"wp-block-heading\">3. Gerilimi Do\u011frulay\u0131n<\/h3>\n\n<p class=\"wp-block-paragraph\">K\u0131sa devre performans\u0131, nominal \u00e7al\u0131\u015fma gerilimi ile ili\u015fkilendirilebilir.<\/p>\n\n<p class=\"wp-block-paragraph\">Bu nedenle, gerilim durumu kA de\u011feri ile birlikte kontrol edilmelidir.<\/p>\n\n<h3 class=\"wp-block-heading\">4. Tam Olarak Ayn\u0131 \u00dcr\u00fcn\u00fc Bul<\/h3>\n\n<p class=\"wp-block-paragraph\">Do\u011frula:<\/p>\n\n<ul class=\"wp-block-list\">\n\n<li>tam model<\/li>\n\n\n<li>gerilim<\/li>\n\n\n<li>mevcut<\/li>\n\n\n<li>direkler<\/li>\n\n\n<li>yol e\u011frisi<\/li>\n\n\n<li>k\u0131r\u0131lma kapasitesi<\/li>\n\n\n<li>ilgili standart<\/li>\n\n\n<li>varyant<\/li>\n\n<\/ul>\n\n<h3 class=\"wp-block-heading\">5. Gerekti\u011finde Teknik Belgeleri Talep Edin<\/h3>\n\n<p class=\"wp-block-paragraph\">Proje resmi m\u00fchendislik do\u011frulamas\u0131 gerektiriyorsa, yaln\u0131zca pazarlama sayfas\u0131ndaki \u00f6zet bilgilere g\u00fcvenmek yerine, \u00fcr\u00fcnle ilgili ayr\u0131nt\u0131l\u0131 belgeleri talep edin.<\/p>\n\n<figure data-spectra-id=\"spectra-3628f3a6-84af-4e41-82b9-fde508bbcb21\" class=\"wp-block-image aligncenter size-full has-custom-border\" ><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/mcb-breaking-capacity-verification-flow.jpg\" alt=\"Proje gereksinimlerinden kesin modele kadar kavramsal MCB kesme kapasitesi do\u011frulama s\u00fcreci\" class=\"wp-image-711\"  width=\"1672\" height=\"941\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/mcb-breaking-capacity-verification-flow.jpg 1672w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/mcb-breaking-capacity-verification-flow-600x338.jpg 600w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/mcb-breaking-capacity-verification-flow-300x169.jpg 300w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/mcb-breaking-capacity-verification-flow-1024x576.jpg 1024w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/mcb-breaking-capacity-verification-flow-768x432.jpg 768w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/mcb-breaking-capacity-verification-flow-1536x864.jpg 1536w\" sizes=\"auto, (max-width: 1672px) 100vw, 1672px\" \/><figcaption class=\"wp-element-caption\">Kavramsal do\u011frulama s\u00fcreci: proje gereksinimleri, \u00f6ng\u00f6r\u00fclen k\u0131sa devre ak\u0131m\u0131, standart ve gerilim, kesme kapasitesi de\u011feri ve kesin model onay\u0131.<\/figcaption><\/figure>\n\n<h2 id=\"common-mistakes\" class=\"wp-block-heading\">6 kA ve 10 kA MCB'lerde S\u0131k G\u00f6r\u00fclen Hatalar<\/h2>\n\n<h3 class=\"wp-block-heading\">\u201c6 kA konut ama\u00e7l\u0131, 10 kA ise end\u00fcstriyel ama\u00e7l\u0131d\u0131r\u201d<\/h3>\n\n<p class=\"wp-block-paragraph\">Bu \u00e7ok genel bir ifade.<\/p>\n\n<p class=\"wp-block-paragraph\">Do\u011fru kesme kapasitesi, olas\u0131 ar\u0131za ko\u015fullar\u0131na ve ilgili proje gerekliliklerine ba\u011fl\u0131d\u0131r.<\/p>\n\n<h3 class=\"wp-block-heading\">\u201c10 kA, 6 kA\u2019dan Daha G\u00fcvenlidir\u201d<\/h3>\n\n<p class=\"wp-block-paragraph\">Daha y\u00fcksek bir kopma kapasitesi de\u011feri, evrensel bir g\u00fcvenlik derecesi anlam\u0131na gelmez.<\/p>\n\n<p class=\"wp-block-paragraph\">Burada \u00f6nemli olan soru, kesicinin nominal de\u011ferinin tesisin ger\u00e7ek ihtiyac\u0131n\u0131 kar\u015f\u0131lay\u0131p kar\u015f\u0131lamad\u0131\u011f\u0131d\u0131r.<\/p>\n\n<h3 class=\"wp-block-heading\">Yaln\u0131zca kA De\u011ferinin Kar\u015f\u0131la\u015ft\u0131r\u0131lmas\u0131<\/h3>\n\n<p class=\"wp-block-paragraph\">K\u0131r\u0131lma kapasitesi de\u011feri, a\u015fa\u011f\u0131dakilerle birlikte de\u011ferlendirilmelidir:<\/p>\n\n<ul class=\"wp-block-list\">\n\n<li>standart<\/li>\n\n\n<li>gerilim<\/li>\n\n\n<li>derecelendirme kodu<\/li>\n\n\n<li>tam \u00fcr\u00fcn<\/li>\n\n<\/ul>\n\n<h3 class=\"wp-block-heading\">Icn ve Ics\u2019yi Birbirinin Ayn\u0131s\u0131 Olarak Ele Alma<\/h3>\n\n<p class=\"wp-block-paragraph\">Bunlar, birbirinden farkl\u0131 standartla\u015ft\u0131r\u0131lm\u0131\u015f k\u0131sa devre performans kavramlar\u0131d\u0131r.<\/p>\n\n<h3 class=\"wp-block-heading\">SCCR panelinin MCB\u2019nin kesme kapasitesine e\u015fit oldu\u011fu varsay\u0131m\u0131<\/h3>\n\n<p class=\"wp-block-paragraph\">Tek bir kesicinin k\u0131sa devre dayan\u0131m de\u011ferini, t\u00fcm sistemin k\u0131sa devre ak\u0131m dayan\u0131m de\u011feriyle otomatik olarak e\u015fitlemeyin.<\/p>\n\n<p class=\"wp-block-paragraph\">Sistem ve montaj de\u011ferleri, kendilerine \u00f6zg\u00fc gereklilikleri i\u00e7erir.<\/p>\n\n<h3 class=\"wp-block-heading\">\u00dcr\u00fcn Sayfas\u0131n\u0131 Ar\u0131za Ak\u0131m\u0131 Hesaplamas\u0131 Olarak Kullanma<\/h3>\n\n<p class=\"wp-block-paragraph\">Bir \u00fcr\u00fcn sayfas\u0131, s\u00f6z konusu kesicinin hangi \u00f6zelliklere sahip oldu\u011funu size g\u00f6sterebilir.<\/p>\n\n<p class=\"wp-block-paragraph\">Bu cihaz, tesisat\u0131n\u0131zdaki olas\u0131 k\u0131sa devre ak\u0131m\u0131n\u0131 belirleyemez.<\/p>\n\n<h2 id=\"mcb-rfq\" class=\"wp-block-heading\">Al\u0131c\u0131lar, bir MCB teklif talebine neleri dahil etmelidir?<\/h2>\n\n<p class=\"wp-block-paragraph\">MCB tedarik talebinin daha net olmas\u0131 i\u00e7in l\u00fctfen a\u015fa\u011f\u0131dakileri belirtin:<\/p>\n\n<ul class=\"wp-block-list\">\n\n<li>sistem gerilimi<\/li>\n\n\n<li>gerekli ak\u0131m de\u011feri<\/li>\n\n\n<li>direk d\u00fczeni<\/li>\n\n\n<li>gerekli hareket e\u011frisi<\/li>\n\n\n<li>gerekli kopma kapasitesi<\/li>\n\n\n<li>belirtilmi\u015fse ge\u00e7erli standart<\/li>\n\n\n<li>Belirtilmi\u015fse, gerekli ICN \/ ICS \/ di\u011fer s\u0131n\u0131fland\u0131rma kodlar\u0131<\/li>\n\n\n<li>miktar<\/li>\n\n\n<li>ba\u015fvuru<\/li>\n\n\n<li>gerekli teknik belgeler<\/li>\n\n<\/ul>\n\n<p class=\"wp-block-paragraph\">Gerekli olan kesin k\u0131sa devre dayan\u0131m de\u011feri hen\u00fcz belirlenmemi\u015fse, nihai se\u00e7imi yaln\u0131zca \u00fcr\u00fcn\u00fcn piyasada bulunabilirli\u011fine dayand\u0131rmadan \u00f6nce bu gereklilik elektrik tasar\u0131m a\u015famas\u0131nda \u00e7\u00f6z\u00fclmelidir.<\/p>\n\n<h2 id=\"frequently-asked-questions\" class=\"wp-block-heading\">S\u0131k Sorulan Sorular<\/h2>\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>6 kA ile 10 kA\u2019l\u0131k MCB Aras\u0131ndaki Fark Nedir?<\/summary>\n\n<p class=\"wp-block-paragraph\">Aradaki fark, ge\u00e7erli nominal ko\u015fullar alt\u0131nda yay\u0131nlanan k\u0131sa devre kesme kapasitesi de\u011ferleridir. Di\u011fer t\u00fcm ko\u015fullar e\u015fde\u011fer oldu\u011funda, 10 kA\u2019l\u0131k bir de\u011fer, 6 kA\u2019ya k\u0131yasla daha y\u00fcksek bir kesme kapasitesini ifade eder.<\/p>\n\n<\/details>\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>10 kA, 6 kA\u2019dan daha m\u0131 iyidir?<\/summary>\n\n<p class=\"wp-block-paragraph\">Otomatik olarak de\u011fil. 10 kA, daha y\u00fcksek bir kesme kapasitesi de\u011feri sa\u011flar; ancak do\u011fru gereksinim, \u00f6ng\u00f6r\u00fclen k\u0131sa devre ak\u0131m\u0131na ve ilgili proje \u015fartnamesine ba\u011fl\u0131d\u0131r.<\/p>\n\n<\/details>\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>MCB\u2019de \u201cIcn\u201d Ne Anlama Gelir?<\/summary>\n\n<p class=\"wp-block-paragraph\">IEC\/EN 60898-1 standard\u0131na g\u00f6re, Icn, nominal k\u0131sa devre kapasitesini ifade eder. Bu de\u011fer, kullan\u0131m noktas\u0131nda meydana gelmesi muhtemel k\u0131sa devre ak\u0131m\u0131 g\u00f6z \u00f6n\u00fcnde bulundurularak de\u011ferlendirilmelidir.<\/p>\n\n<\/details>\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>ICS Nedir?<\/summary>\n\n<p class=\"wp-block-paragraph\">Ics, ilgili standartta tan\u0131mlanan hizmet k\u0131sa devre kesme kapasitesi kavram\u0131d\u0131r. Bu, Icn\u2019nin sadece ba\u015fka bir ad\u0131 de\u011fildir.<\/p>\n\n<\/details>\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>10 kA\u2019l\u0131k bir MCB, 6 kA\u2019l\u0131k bir MCB\u2019den daha h\u0131zl\u0131 m\u0131 devre d\u0131\u015f\u0131 kal\u0131r?<\/summary>\n\n<p class=\"wp-block-paragraph\">Sadece kA kesme kapasitesi de\u011feri bu sorunun cevab\u0131n\u0131 vermez. A\u00e7ma davran\u0131\u015f\u0131, kesicinin kesme kapasitesi de\u011ferinden \u00e7\u0131kar\u0131lmak suretiyle de\u011fil, kesicinin a\u00e7ma karakteristi\u011fi ve zaman-ak\u0131m verileri kullan\u0131larak de\u011ferlendirilmelidir.<\/p>\n\n<\/details>\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>RITOKS, hem 6 kA hem de 10 kA'l\u0131k MCB'ler sunuyor mu?<\/summary>\n\n<p class=\"wp-block-paragraph\">Evet. Mevcut yay\u0131nlanm\u0131\u015f \u00fcr\u00fcn aileleri aras\u0131nda RTSXD02 ve RTSXD03 gibi 6 kA se\u00e7enekleri ile RTSXD01 ve RTSXD04 gibi 10 kA Icn \/ 7,5 kA Ics se\u00e7enekleri bulunmaktad\u0131r. RTS-ACM60 modelinde tipik de\u011fer olarak 6 kA belirtilmi\u015ftir ve bu de\u011fer, varyant onay\u0131na tabidir.<\/p>\n\n<\/details>\n\n<div class=\"wp-block-group has-ast-global-color-5-color has-ast-global-color-2-background-color has-text-color has-background is-layout-constrained wp-container-core-group-is-layout-d8cb2258 wp-block-group-is-layout-constrained\" style=\"border-radius:6px;margin-top:48px;padding-top:40px;padding-right:32px;padding-bottom:40px;padding-left:32px\">\n\n<h2 class=\"wp-block-heading\">AC MCB se\u00e7eneklerini kar\u015f\u0131la\u015ft\u0131r\u0131rken yard\u0131ma m\u0131 ihtiyac\u0131n\u0131z var?<\/h2>\n\n<p class=\"wp-block-paragraph\">RITOKS, farkl\u0131 \u00f6zelliklere sahip AC minyat\u00fcr devre kesici serilerini piyasaya s\u00fcrmektedir:<\/p>\n\n<ul class=\"wp-block-list\">\n\n<li>ak\u0131m de\u011ferleri<\/li>\n\n\n<li>direk d\u00fczenleri<\/li>\n\n\n<li>B\/C\/D e\u011frilerinin mevcut olup olmad\u0131\u011f\u0131<\/li>\n\n\n<li>k\u0131r\u0131lma mukavemeti de\u011ferleri<\/li>\n\n\n<li>montaj bi\u00e7imleri<\/li>\n\n<\/ul>\n\n<p class=\"wp-block-paragraph\">\u015eunu kullan\u0131n: <a href=\"https:\/\/ritoks.com\/tr\/ac-mcb-rfq-checklist\/\">AC MCB Teklif Talebi Kontrol Listesi<\/a> gerekli elektriksel parametreleri ve projeye \u00f6zg\u00fc k\u0131sa devre gereksinimlerini sa\u011flamak.<\/p>\n\n<p class=\"wp-block-paragraph\">Buradaki ama\u00e7, sadece kA de\u011feri en y\u00fcksek olan kesiciyi se\u00e7mek de\u011fil, gerekli teknik \u00f6zellikleri onaylanm\u0131\u015f bir \u00fcr\u00fcn konfig\u00fcrasyonuyla e\u015fle\u015ftirmektir.<\/p>\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-ast-global-color-0-background-color has-background wp-element-button\" href=\"https:\/\/ritoks.com\/tr\/product-category\/ac-power-protection\/miniature-circuit-breakers\/\">AC Minyat\u00fcr Devre Kesicileri G\u00f6r\u00fcnt\u00fcle \u2192<\/a><\/div>\n\n\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-ast-global-color-0-background-color has-background wp-element-button\" href=\"https:\/\/ritoks.com\/tr\/ac-mcb-selection-guide\/\">AC MCB Se\u00e7im K\u0131lavuzunu okuyun \u2192<\/a><\/div>\n\n\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-ast-global-color-0-background-color has-background wp-element-button\" href=\"https:\/\/ritoks.com\/tr\/b-curve-vs-c-curve-vs-d-curve-mcb\/\">B, C ve D e\u011frili MCB\u2019leri kar\u015f\u0131la\u015ft\u0131r\u0131n \u2192<\/a><\/div>\n\n\n<div class=\"wp-block-button is-style-outline is-style-outline--1\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/ritoks.com\/tr\/contact-us\/\">RITOKS ile \u0130leti\u015fime Ge\u00e7in \u2192 Fiyat Teklifi \u0130steyin<\/a><\/div>\n\n<\/div>\n\n<\/div>\n\n<\/div>","protected":false},"excerpt":{"rendered":"<p>6kA vs 10kA MCB: Understanding Breaking-Capacity Ratings When comparing miniature circuit breakers, 6kA and 10kA refer to short-circuit breaking-capacity ratings. [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"no-sidebar","site-content-layout":"page-builder","ast-site-content-layout":"full-width-container","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"disabled","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"disabled","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ritoks_resource_detail_renderer":null,"ritoks_resource_product_cat_term_id":0,"footnotes":""},"categories":[64],"tags":[],"class_list":["post-706","post","type-post","status-publish","format-standard","hentry","category-circuit-protection"],"acf":[],"spectra_blocks_featured_image_url":null,"spectra_blocks_author_info":{"display_name":"RITOKS","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/6d7d0fc73468198f994ab13ef6eb6558c53b6ed1ad86364d5165efe8bdf8eb4a?s=96&d=mm&r=g","author_link":"https:\/\/ritoks.com\/tr\/author\/dazzlingwqbgmail-com\/","description":""},"_links":{"self":[{"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/posts\/706","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/comments?post=706"}],"version-history":[{"count":5,"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/posts\/706\/revisions"}],"predecessor-version":[{"id":1961,"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/posts\/706\/revisions\/1961"}],"wp:attachment":[{"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/media?parent=706"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/categories?post=706"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/tags?post=706"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}