{"id":715,"date":"2026-09-06T02:35:35","date_gmt":"2026-09-06T02:35:35","guid":{"rendered":"https:\/\/ritoks.com\/?p=715"},"modified":"2026-09-20T06:54:40","modified_gmt":"2026-09-20T06:54:40","slug":"1pn-vs-2p-circuit-breaker","status":"publish","type":"post","link":"https:\/\/ritoks.com\/tr\/1pn-vs-2p-circuit-breaker\/","title":{"rendered":"1P+N ve 2P Devre Kesiciler: Al\u0131c\u0131lar \u0130\u00e7in Yap\u0131land\u0131rma Sorular\u0131"},"content":{"rendered":"<div class=\"wp-block-group alignfull has-ast-global-color-5-background-color has-background is-layout-constrained wp-container-core-group-is-layout-1079f00e wp-block-group-is-layout-constrained\" style=\"padding-top:56px;padding-right:24px;padding-bottom:48px;padding-left:24px\">\n<h1 class=\"wp-block-heading\" style=\"font-size:42px;font-weight:700;letter-spacing:0px;line-height:1.15\">1P+N ve 2P Devre Kesiciler: Al\u0131c\u0131lar \u0130\u00e7in Yap\u0131land\u0131rma Sorular\u0131<\/h1>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">Al\u0131c\u0131lar 1P+N ve 2P devre kesicileri kar\u015f\u0131la\u015ft\u0131rd\u0131klar\u0131nda, ilk fark ettikleri \u015fey kutup tan\u0131mlamas\u0131d\u0131r. Ancak etiket tek ba\u015f\u0131na, belirli bir devre kesicinin n\u00f6tr iletkeni nas\u0131l i\u015fledi\u011fini, ka\u00e7 kutup korundu\u011funu, anahtarlama i\u015fleminin e\u015fzamanl\u0131 olup olmad\u0131\u011f\u0131n\u0131 veya cihaz\u0131n belirli bir izolasyon i\u015flevi sa\u011flamay\u0131 ama\u00e7lay\u0131p ama\u00e7lamad\u0131\u011f\u0131n\u0131 tam olarak a\u00e7\u0131klamaz.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Farkl\u0131 \u00fcreticiler bu konfig\u00fcrasyonlar\u0131 farkl\u0131 \u015fekillerde belgeleyebilir. Al\u0131c\u0131 i\u00e7in daha g\u00fcvenli olan soru, sadece \u201c1P+N mi yoksa 2P mi daha iyidir?\u201d \u015feklinde de\u011fildir. As\u0131l soru \u015fudur: \u201c\u00dcretici bu konfig\u00fcrasyon i\u00e7in tam olarak neyi belgeliyor ve bu, proje gereksinimleriyle uyumlu mu?\u201d<\/p>\n\n\n\n<figure data-spectra-id=\"spectra-12f8d25c-c9d6-457e-81ba-11db1566a959\" class=\"wp-block-image size-full\" ><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/representative-single-phase-ac-mcb-formats.png\" alt=\"End\u00fcstriyel bir \u00e7al\u0131\u015fma tezgah\u0131 \u00fczerinde yer alan tipik tek fazl\u0131 AC minyat\u00fcr devre kesici modelleri\" class=\"wp-image-717\" width=\"1672\" height=\"941\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/representative-single-phase-ac-mcb-formats.png 1672w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/representative-single-phase-ac-mcb-formats-600x338.png 600w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/representative-single-phase-ac-mcb-formats-300x169.png 300w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/representative-single-phase-ac-mcb-formats-1024x576.png 1024w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/representative-single-phase-ac-mcb-formats-768x432.png 768w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/representative-single-phase-ac-mcb-formats-1536x864.png 1536w\" sizes=\"auto, (max-width: 1672px) 100vw, 1672px\" \/><figcaption class=\"wp-element-caption\">End\u00fcstriyel bir \u00e7al\u0131\u015fma tezgah\u0131 ortam\u0131nda g\u00f6sterilen tipik AC MCB konfig\u00fcrasyonlar\u0131.<\/figcaption><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-group is-layout-constrained wp-container-core-group-is-layout-8eabd858 wp-block-group-is-layout-constrained\" style=\"padding-top:48px;padding-right:24px;padding-bottom:24px;padding-left:24px\">\n<h2 class=\"wp-block-heading\">\u0130\u00e7indekiler<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"#quick-comparison\">H\u0131zl\u0131 kar\u015f\u0131la\u015ft\u0131rma<\/a><\/li>\n\n\n<li><a href=\"#what-1pn-means\">1P+N ne anlama gelir?<\/a><\/li>\n\n\n<li><a href=\"#what-2p-means\">2P ne anlama gelir?<\/a><\/li>\n\n\n<li><a href=\"#ritoks-options\">Mevcut RITOKS se\u00e7enekleri<\/a><\/li>\n\n\n<li><a href=\"#buyer-questions\">Al\u0131c\u0131lar\u0131n sormas\u0131 gereken sorular<\/a><\/li>\n\n\n<li><a href=\"#faq\">S\u0131k sorulan sorular<\/a><\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-group is-layout-constrained wp-container-core-group-is-layout-dd6b76d8 wp-block-group-is-layout-constrained\" style=\"padding-top:32px;padding-right:24px;padding-bottom:48px;padding-left:24px\">\n<h2 class=\"wp-block-heading\" id=\"quick-comparison\">H\u0131zl\u0131 Kar\u015f\u0131la\u015ft\u0131rma: 1P+N ile 2P<\/h2>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table class=\"has-fixed-layout\"><thead><tr><th>Yap\u0131land\u0131rma<\/th><th>Etiketin Size G\u00fcvenli Bir \u015eekilde Anlatt\u0131klar\u0131<\/th><th>Hala Do\u011frulanmas\u0131 Gerekenler<\/th><\/tr><\/thead><tbody><tr><td>1P+N<\/td><td>\u00dcr\u00fcn, faz art\u0131 n\u00f6tr konfig\u00fcrasyonunda sunulmaktad\u0131r<\/td><td>Hangi kutup korunur, n\u00f6tr anahtarlama davran\u0131\u015f\u0131, mekanizma, mod\u00fcl geni\u015fli\u011fi ve izolasyon i\u015flevi<\/td><\/tr><tr><td>2P<\/td><td>\u00dcr\u00fcn, iki kutuplu bir konfig\u00fcrasyon olarak sunulmaktad\u0131r<\/td><td>Her bir kutupun koruma davran\u0131\u015f\u0131, iletken atamas\u0131, anahtarlama d\u00fczeni, mekanizma ve uygulama gereksinimleri<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Buradaki \u00f6nemli ayr\u0131m \u015fudur: <strong>Kutup tan\u0131mlamas\u0131, i\u00e7 davran\u0131\u015f\u0131n eksiksiz bir dok\u00fcmantasyonu ile ayn\u0131 \u015fey de\u011fildir.<\/strong> Bir al\u0131c\u0131, yaln\u0131zca katalog ba\u015fl\u0131\u011f\u0131nda yaz\u0131l\u0131 harflere g\u00fcvenmek yerine, \u00fcr\u00fcn\u00fcn tam modelini do\u011frulamal\u0131d\u0131r.<\/p>\n\n\n\n<figure data-spectra-id=\"spectra-5ad302c2-4c8d-476f-b358-f35a1d0b1e58\" class=\"wp-block-image size-full\" ><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/1pn-vs-2p-circuit-breaker-configuration-comparison.png\" alt=\"1P art\u0131 n\u00f6tr ve 2 kutuplu devre kesici konfig\u00fcrasyonlar\u0131n\u0131n kavramsal kar\u015f\u0131la\u015ft\u0131rmas\u0131\" class=\"wp-image-718\" width=\"1672\" height=\"941\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/1pn-vs-2p-circuit-breaker-configuration-comparison.png 1672w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/1pn-vs-2p-circuit-breaker-configuration-comparison-600x338.png 600w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/1pn-vs-2p-circuit-breaker-configuration-comparison-300x169.png 300w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/1pn-vs-2p-circuit-breaker-configuration-comparison-1024x576.png 1024w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/1pn-vs-2p-circuit-breaker-configuration-comparison-768x432.png 768w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/1pn-vs-2p-circuit-breaker-configuration-comparison-1536x864.png 1536w\" sizes=\"auto, (max-width: 1672px) 100vw, 1672px\" \/><figcaption class=\"wp-element-caption\">Kavramsal 1P+N ve 2P konfig\u00fcrasyon kar\u015f\u0131la\u015ft\u0131rmas\u0131. Korunan kutup ve n\u00f6tr\u00fcn tam davran\u0131\u015f\u0131, modele \u00f6zg\u00fc belgelerden teyit edilmelidir.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"what-1pn-means\">1P+N Ne Anlama Gelir?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">En temel d\u00fczeyde, 1P+N ifadesi, kesicinin bir faz kutbu art\u0131 bir n\u00f6tr kutbu etraf\u0131nda yap\u0131land\u0131r\u0131ld\u0131\u011f\u0131n\u0131 g\u00f6sterir. Bu iki kutbun i\u00e7inde neler oldu\u011fu ise \u00fcr\u00fcn\u00fcn tasar\u0131m\u0131na ba\u011fl\u0131d\u0131r.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Bir \u00fcretici, hangi kutupta a\u015f\u0131r\u0131 ak\u0131m korumas\u0131 bulundu\u011funu, n\u00f6tr kutupun anahtarlan\u0131p anahtarlanmad\u0131\u011f\u0131n\u0131, n\u00f6tr kutupun kendisinin korunup korunmad\u0131\u011f\u0131n\u0131, kutuplar\u0131n birbirleriyle nas\u0131l \u00e7al\u0131\u015ft\u0131\u011f\u0131n\u0131 ve gerekli ba\u011flant\u0131 d\u00fczenini belgeleyebilir. \u00dcr\u00fcn sayfas\u0131nda yaln\u0131zca \u201c1P+N\u201d yaz\u0131yorsa, bu ayr\u0131nt\u0131lar\u0131n hi\u00e7biri otomatik olarak \u00e7\u0131kar\u0131lmamal\u0131d\u0131r.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u00dcreticiye \u00d6zg\u00fc \u00d6rnekler<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/library.e.abb.com\/public\/57b0a247cedd428db48a4c905bd7403b\/2024010307644548%2820240902-20290618%29.pdf\" rel=\"nofollow noopener\" target=\"_blank\">Belirli S200 serisi yap\u0131land\u0131rmalar\u0131na ili\u015fkin ABB belgeleri<\/a> 1P+N'yi, anahtarl\u0131 bir n\u00f6tr kutuplu tek korumal\u0131 kutup olarak tan\u0131mlar. Bu, \u00fcreticiye \u00f6zg\u00fc bir \u00f6rnektir ve bir RITOKS 1P+N modelinin ayn\u0131 i\u00e7 mimariye sahip oldu\u011funu kan\u0131tlamaz.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/iportal.se.com\/Contents\/docs\/SQD-MG27046_CATALOG.PDF\" rel=\"nofollow noopener\" target=\"_blank\">Schneider Electric\u2019in N40 Faz + N\u00f6tr kesiciye ili\u015fkin belgeleri<\/a> hem faz hem de n\u00f6tr devre d\u0131\u015f\u0131 b\u0131rak\u0131ld\u0131\u011f\u0131nda faz-kutup korumas\u0131n\u0131 a\u00e7\u0131klamaktad\u0131r. Yine, bu durum belgelenmi\u015f Schneider \u00fcr\u00fcn\u00fc i\u00e7in ge\u00e7erlidir; ba\u015fka bir \u00fcreticinin belgelenmemi\u015f bir modeli i\u00e7in ge\u00e7erli de\u011fildir.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"what-2p-means\">2P Ne Anlama Gelir?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u201c2P\u201d i\u015fareti, \u00fcr\u00fcn\u00fcn iki kutuplu bir devre kesici konfig\u00fcrasyonu olarak sunuldu\u011funu belirtir. Ancak bu bilgi tek ba\u015f\u0131na, her \u00fcr\u00fcn ailesinde her bir kutupun hangi i\u015flevi g\u00f6rd\u00fc\u011f\u00fcn\u00fc belirlemez.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Baz\u0131 \u00fcreticilere \u00f6zg\u00fc 2P MCB\u2019lerde her iki kutup da a\u00e7\u0131k\u00e7a koruma alt\u0131nda oldu\u011fu belirtilir. \u00d6rne\u011fin, <a href=\"https:\/\/hager.com\/intl-en\/products\/catalog\/product\/download\/id\/MB225A\" rel=\"nofollow noopener\" target=\"_blank\">Hager, MB206A modelinin iki korumal\u0131 kutup ve toplamda iki kutup i\u00e7erdi\u011fini belirtmektedir<\/a>. Eaton, belirli 2P MCB\u2019ler i\u00e7in benzer \u00fcr\u00fcne \u00f6zg\u00fc veriler yay\u0131nlamaktad\u0131r. Bu \u00f6rnekler, kesin belgelemenin neden \u00f6nemli oldu\u011funu g\u00f6stermektedir; ancak her 2P kesici i\u00e7in evrensel bir tan\u0131m olu\u015fturmamaktad\u0131r.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Yap\u0131land\u0131rma Etiketleri Her \u0130\u00e7 Ayr\u0131nt\u0131y\u0131 Tan\u0131mlamaz<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">1P+N, Evrensel Bir \u0130\u00e7 Mimari K\u0131sayolu De\u011fildir<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Bir al\u0131c\u0131, b\u00fcy\u00fck bir \u00fcreticinin belgelenmi\u015f 1P+N tasar\u0131m\u0131n\u0131 g\u00f6rd\u00fc\u011f\u00fcnde, ayn\u0131 d\u00fczenlemenin her durumda ge\u00e7erli oldu\u011funu varsayabilir. Bu riskli bir durumdur. Katalog etiketi genel yap\u0131land\u0131rmay\u0131 belirtir; modele \u00f6zg\u00fc teknik belgeler ise korumal\u0131 kutup d\u00fczenini, n\u00f6tr davran\u0131\u015f\u0131n\u0131, anahtarlama davran\u0131\u015f\u0131n\u0131, kablolama d\u00fczenini, cihaz geni\u015fli\u011fini ve ilgili \u00e7al\u0131\u015fma ayr\u0131nt\u0131lar\u0131n\u0131 do\u011frulamal\u0131d\u0131r.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">2P, \u0130letkenleri Otomatik Olarak Tan\u0131mlamaz<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u201c2P her zaman faz art\u0131 n\u00f6tr anlam\u0131na gelir\u201d ifadesi \u00e7ok genel bir tan\u0131md\u0131r. \u0130ki kutuplu bir kesici, iki kutuplu bir cihaz konfig\u00fcrasyonunu ifade eder. Ger\u00e7ek iletken d\u00fczeni, sisteme, \u00fcr\u00fcn belgelerine ve proje tasar\u0131m\u0131na ba\u011fl\u0131d\u0131r. Etiket tek ba\u015f\u0131na, zorunlu faz\/n\u00f6tr atamalar\u0131n\u0131, iki hatl\u0131 \u00e7al\u0131\u015fmay\u0131, gerekli n\u00f6tr i\u015flemlerini, izolasyon gerekliliklerini veya yerel kablolama uyumlulu\u011funu belirlememelidir.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">N\u00f6tr Anahtarlama ve N\u00f6tr Korumas\u0131 Ayr\u0131 Konulard\u0131r<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Bir kutup, belirli bir \u00fcr\u00fcn tasar\u0131m\u0131nda mutlaka \u201ckorunan kutup\u201d olarak tan\u0131mlanmasa bile anahtarlama i\u015flemine dahil olabilir. Schneider N40 \u00f6rne\u011fi bu ayr\u0131m\u0131 a\u00e7\u0131k\u00e7a g\u00f6stermektedir. Al\u0131c\u0131lar\u0131n sormas\u0131 gereken daha iyi sorular aras\u0131nda, n\u00f6tr\u00fcn anahtarlan\u0131p anahtarlanmad\u0131\u011f\u0131, korunup korunmad\u0131\u011f\u0131, kutuplar\u0131n mekanik olarak birbirine ba\u011fl\u0131 olup olmad\u0131\u011f\u0131, anahtarlaman\u0131n e\u015fzamanl\u0131 olup olmad\u0131\u011f\u0131, bir kablo \u015femas\u0131n\u0131n yay\u0131nlan\u0131p yay\u0131nlanmad\u0131\u011f\u0131 ve belirli bir ba\u011flant\u0131 y\u00f6n\u00fcn\u00fcn gerekli olup olmad\u0131\u011f\u0131 yer al\u0131r.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A\u015fa\u011f\u0131da ele al\u0131nan g\u00fcncel RITOKS \u00fcr\u00fcnleri i\u00e7in, s\u00f6z konusu i\u00e7 detaylar hen\u00fcz yay\u0131nlanmam\u0131\u015ft\u0131r; bu nedenle gerekti\u011finde ayr\u0131 olarak teyit edilmelidir.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Mod\u00fcl Geni\u015fli\u011fi de Do\u011frulanmal\u0131d\u0131r<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Kutu kutuplar\u0131, bir kesicinin tam fiziksel geni\u015fli\u011fini her zaman g\u00f6stermez. Farkl\u0131 \u00fcreticiler ve \u00fcr\u00fcn gruplar\u0131, faz ve n\u00f6tr i\u015flevlerini farkl\u0131 \u015fekillerde d\u00fczenleyebilir. Kompakt \u00fcretici \u00f6rnekleri, her 1P+N kesicinin ayn\u0131 say\u0131da DIN ray\u0131 mod\u00fcl\u00fcn\u00fc kaplad\u0131\u011f\u0131 anlam\u0131na gelmez.<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>Cihaz\u0131n toplam geni\u015fli\u011fi<\/li>\n<li>DIN mod\u00fcllerinin say\u0131s\u0131<\/li>\n<li>Terminal d\u00fczeni<\/li>\n<li>Biti\u015fik cihazlar aras\u0131ndaki bo\u015fluk<\/li>\n<li>Baralar aras\u0131 uyumluluk<\/li><\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Mevcut RITOKS \u00fcr\u00fcnleri i\u00e7in, yaln\u0131zca ilgili model i\u00e7in a\u00e7\u0131k\u00e7a yay\u0131nlanm\u0131\u015f boyutlar\u0131 veya montaj ayr\u0131nt\u0131lar\u0131n\u0131 kullan\u0131n. Kablolama y\u00fcksekli\u011fi boyutunu mod\u00fcl geni\u015fli\u011fi olarak de\u011ferlendirmeyin.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-group alignfull has-ast-global-color-5-background-color has-background is-layout-constrained wp-container-core-group-is-layout-e6610c25 wp-block-group-is-layout-constrained\" style=\"padding-top:56px;padding-right:24px;padding-bottom:56px;padding-left:24px\">\n<h2 class=\"wp-block-heading\" id=\"ritoks-options\">Mevcut RITOKS 1P+N ve 2P Se\u00e7enekleri<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Mevcut <a href=\"https:\/\/ritoks.com\/tr\/product-category\/ac-power-protection\/\">AC G\u00fc\u00e7 Korumas\u0131<\/a> aral\u0131k ve <a href=\"https:\/\/ritoks.com\/tr\/product-category\/ac-power-protection\/miniature-circuit-breakers\/\">Minyat\u00fcr Devre Kesiciler (MCB)<\/a> Kategori, yap\u0131land\u0131rman\u0131n kullan\u0131labilirli\u011fini do\u011frular. \u0130ncelenen modeller i\u00e7in i\u00e7taki n\u00f6tr veya kutup davran\u0131\u015flar\u0131n\u0131 belgelememektedir.<\/p>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table class=\"has-fixed-layout\"><thead><tr><th>RITOKS Modeli<\/th><th>Yay\u0131nlanm\u0131\u015f Yap\u0131land\u0131rma Kullan\u0131labilirli\u011fi<\/th><th>\u0130\u00e7 Kutup \/ N\u00f6tr Davran\u0131\u015f\u0131<\/th><\/tr><\/thead><tbody><tr><td>RTSXD01<\/td><td>1P+N, 2P, 3P, 3P+N, 4P<\/td><td>Belgelenmemi\u015f<\/td><\/tr><tr><td>RTSXD03<\/td><td>1P+N<\/td><td>Belgelenmemi\u015f<\/td><\/tr><tr><td>RTSXD02<\/td><td>1P+N<\/td><td>Belgelenmemi\u015f<\/td><\/tr><tr><td>RTSXD04<\/td><td>1P+N, 2P, 3P, 3P+N, 4P<\/td><td>Belgelenmemi\u015f<\/td><\/tr><tr><td>RTS-ACM60<\/td><td>1P, 2P<\/td><td>1P+N yay\u0131nlanmam\u0131\u015ft\u0131r; 2P\u2019nin dahili davran\u0131\u015f\u0131 belgelenmemi\u015ftir<\/td><\/tr><tr><td>RTS-AC47<\/td><td>1P, 2P, 3P, 4P<\/td><td>1P+N yay\u0131nlanmam\u0131\u015ft\u0131r; 2P\u2019nin dahili davran\u0131\u015f\u0131 belgelenmemi\u015ftir<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Bu tablo kas\u0131tl\u0131 olarak ihtiyatl\u0131 bir yakla\u015f\u0131m sergilemektedir: Tarafs\u0131z kutbun nas\u0131l korundu\u011fu veya nas\u0131l devreye al\u0131nd\u0131\u011f\u0131na dair herhangi bir iddiada bulunmadan, hangi konfig\u00fcrasyonlar\u0131n yay\u0131nland\u0131\u011f\u0131n\u0131 do\u011frulamaktad\u0131r.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Hem 1P+N hem de 2P Se\u00e7eneklerini Sunan Modeller<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/ritoks.com\/tr\/products\/miniature-circuit-breaker-63a-10ka\/\">RTSXD01<\/a> 1P+N, 2P, 3P, 3P+N ve 4P se\u00e7eneklerini sunmaktad\u0131r. Sayfas\u0131nda ayr\u0131ca AC 230\/400 V, 1\u201363 A ve B\/C\/D e\u011frisi se\u00e7eneklerinin mevcut oldu\u011fu belirtilmektedir. 1P+N versiyonunun i\u00e7 n\u00f6tr davran\u0131\u015f\u0131n\u0131 veya 2P versiyonunun koruma d\u00fczenlemesini tan\u0131mlayacak kadar yeterli bilgi yay\u0131nlamamaktad\u0131r.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">RTSXD04, ayn\u0131 yap\u0131land\u0131rma setini yay\u0131nlamaktad\u0131r. Yap\u0131land\u0131rman\u0131n kullan\u0131labilirli\u011fi do\u011frulanm\u0131\u015ft\u0131r, ancak kutuplar baz\u0131nda ayr\u0131nt\u0131l\u0131 i\u00e7 davran\u0131\u015f do\u011frulanmam\u0131\u015ft\u0131r.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">1P+N Olarak Yay\u0131nlanan \u0130ncelenen Modeller<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/ritoks.com\/tr\/products\/1pn-miniature-circuit-breaker-32a-6ka\/\">RTSXD02<\/a> RTSXD03 modelleri ise her biri 240 V AC, 1\u201332 A, 1P+N olarak piyasaya sunulmu\u015ftur; 6 kA kesme kapasitesine ve B\/C e\u011frisi se\u00e7ene\u011fine sahiptir. Konfig\u00fcrasyon etiketleri do\u011frulanm\u0131\u015ft\u0131r; ancak mevcut \u00fcr\u00fcn sayfalar\u0131nda n\u00f6tr devre anahtarlama ve koruma ayr\u0131nt\u0131lar\u0131 belirtilmemi\u015ftir.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Yay\u0131nlanm\u0131\u015f 1P+N De\u011feri Olmadan 2P De\u011feri Sunan Modeller<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/ritoks.com\/tr\/products\/m60-ac-miniature-circuit-breaker-6-63a\/\">RTS-ACM60<\/a> 1P ve 2P konfig\u00fcrasyonlar\u0131n\u0131 yay\u0131nlarken, RTS-AC47 ise 1P, 2P, 3P ve 4P konfig\u00fcrasyonlar\u0131n\u0131 yay\u0131nlamaktad\u0131r. \u015eu anda her iki modelde de 1P+N se\u00e7ene\u011fi bulunmamaktad\u0131r. Bu modellerin 2P dahili koruma veya n\u00f6tr d\u00fczenlemeleri, yaln\u0131zca etiket bilgisine dayanarak \u00e7\u0131kar\u0131lmamal\u0131d\u0131r.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-group is-layout-constrained wp-container-core-group-is-layout-e6610c25 wp-block-group-is-layout-constrained\" style=\"padding-top:56px;padding-right:24px;padding-bottom:56px;padding-left:24px\">\n<h2 class=\"wp-block-heading\">Direk Yap\u0131land\u0131rmas\u0131 Ayr\u0131 Bir Se\u00e7im Parametresidir<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Direk Konfig\u00fcrasyonu, A\u00e7ma E\u011frisinden Farkl\u0131d\u0131r<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Bir \u00fcr\u00fcn, 1P+N, C e\u011frisi veya 2P, C e\u011frisi olarak tan\u0131mlanabilir. Burada 1P+N veya 2P, konfig\u00fcrasyonu ifade ederken, C ise devre kesme karakteristi\u011fini ifade eder. Bunlardan biri di\u011ferini belirlemez. Bkz. <a href=\"https:\/\/ritoks.com\/tr\/b-curve-vs-c-curve-vs-d-curve-mcb\/\">B E\u011frisi, C E\u011frisi ve D E\u011frisi MCB\u2019ler: Aralar\u0131ndaki Fark Nedir?<\/a> ayr\u0131 bir \u201cyolculuk \u00f6zellikleri\u201d sorusu i\u00e7in.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Direk Yap\u0131s\u0131, K\u0131r\u0131lma Kapasitesinden Farkl\u0131d\u0131r<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Ayn\u0131 \u015fekilde, 1P+N veya 2P ifadesi, kesicinin 6 kA, 10 kA veya ba\u015fka bir k\u0131sa devre kapasitesine sahip olup olmad\u0131\u011f\u0131n\u0131 belirtmez. Kesme kapasitesi ayr\u0131 bir elektriksel parametredir. Bkz. <a href=\"https:\/\/ritoks.com\/tr\/6ka-vs-10ka-mcb-breaking-capacity\/\">6 kA ve 10 kA MCB: Kesme Kapasitesi De\u011ferlerini Anlamak<\/a> bu ayr\u0131 soru i\u00e7in.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ak\u0131m, kutuplar, devre kesme e\u011frisi, kesme kapasitesi ve montaj aras\u0131ndaki genel ili\u015fkiyi incelemek i\u00e7in \u015funu kullan\u0131n: <a href=\"https:\/\/ritoks.com\/tr\/ac-mcb-selection-guide\/\">AC MCB Se\u00e7im K\u0131lavuzu<\/a>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"buyer-questions\">Al\u0131c\u0131lar\u0131n 1P+N veya 2P Se\u00e7meden \u00d6nce Sormas\u0131 Gereken Sorular<\/h2>\n\n\n<h3 class=\"wp-block-heading\">1. Hangi direk konfig\u00fcrasyonu belirtilmi\u015ftir?<\/h3>\n<p class=\"wp-block-paragraph\">Proje belgelerinde zaten 1P, 1P+N veya 2P yaz\u0131yorsa, bunu ba\u015flang\u0131\u00e7 noktas\u0131 olarak al\u0131n. Sadece nominal ak\u0131m ayn\u0131 oldu\u011fu i\u00e7in ba\u015fka bir konfig\u00fcrasyona ge\u00e7meyin.<\/p>\n\n<h3 class=\"wp-block-heading\">2. \u00dcretici, n\u00f6tr hakk\u0131nda ne t\u00fcr bilgiler sunmaktad\u0131r?<\/h3>\n<p class=\"wp-block-paragraph\">Model belgelerinde n\u00f6tr anahtarlama, n\u00f6tr koruma, iletken atamas\u0131 ve \u00e7al\u0131\u015ft\u0131rma mekanizmas\u0131n\u0131n do\u011frulan\u0131p do\u011frulanmad\u0131\u011f\u0131n\u0131 sorun. Bu ayr\u0131nt\u0131lar\u0131 katalog ba\u015fl\u0131\u011f\u0131ndan \u00e7\u0131karsamay\u0131n.<\/p>\n\n<h3 class=\"wp-block-heading\">3. Hangi Gerilim ve Ak\u0131m De\u011ferleri Gereklidir?<\/h3>\n<p class=\"wp-block-paragraph\">Kutu konfig\u00fcrasyonu, gerilim veya ak\u0131m\u0131 belirlemez. 1P+N 16A, 1P+N 32A, 2P 16A ve 2P 32A konfig\u00fcrasyonlar\u0131, birbirinden farkl\u0131 besleme kombinasyonlar\u0131d\u0131r.<\/p>\n\n<h3 class=\"wp-block-heading\">4. Hangi hareket e\u011frisi ve frenleme kapasitesi gereklidir?<\/h3>\n<p class=\"wp-block-paragraph\">Belirtilen devre \u00f6zelli\u011fi ve frenleme kapasitesini, kutup konfig\u00fcrasyonundan ba\u011f\u0131ms\u0131z olarak do\u011frulay\u0131n.<\/p>\n\n<h3 class=\"wp-block-heading\">5. Kesin teknik dok\u00fcmantasyon gerekli mi?<\/h3>\n<p class=\"wp-block-paragraph\">OEM panelleri ve teknik tedarik i\u00e7in veri sayfas\u0131, boyut \u00e7izimi, ba\u011flant\u0131 \u015femas\u0131, korumal\u0131 kutup bilgileri, anahtarlama a\u00e7\u0131klamas\u0131, ge\u00e7erli standart bilgileri ve kesin model kodunu talep etmeyi g\u00f6z \u00f6n\u00fcnde bulundurun.<\/p>\n\n\n<p class=\"wp-block-paragraph\">Yerel elektrik y\u00f6netmelikleri ve proje gereklilikleri ayr\u0131 ayr\u0131 do\u011frulanmal\u0131d\u0131r.<\/p>\n\n\n\n<figure data-spectra-id=\"spectra-54bcd86c-6fb2-4c02-85b1-71ec3c39943c\" class=\"wp-block-image size-full\" ><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/mcb-pole-configuration-buyer-verification-flow.png\" alt=\"MCB direk konfig\u00fcrasyonunun se\u00e7ilmesine y\u00f6nelik al\u0131c\u0131 do\u011frulama s\u00fcreci\" class=\"wp-image-719\" width=\"1672\" height=\"941\" srcset=\"https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/mcb-pole-configuration-buyer-verification-flow.png 1672w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/mcb-pole-configuration-buyer-verification-flow-600x338.png 600w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/mcb-pole-configuration-buyer-verification-flow-300x169.png 300w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/mcb-pole-configuration-buyer-verification-flow-1024x576.png 1024w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/mcb-pole-configuration-buyer-verification-flow-768x432.png 768w, https:\/\/ritoks.com\/wp-content\/uploads\/2026\/09\/mcb-pole-configuration-buyer-verification-flow-1536x864.png 1536w\" sizes=\"auto, (max-width: 1672px) 100vw, 1672px\" \/><figcaption class=\"wp-element-caption\">Kavramsal al\u0131c\u0131 do\u011frulama s\u00fcreci: sistem gereksinimlerini, direk konfig\u00fcrasyonunu, belgelenmi\u015f n\u00f6tr davran\u0131\u015f\u0131n\u0131, di\u011fer elektriksel de\u011ferleri ve kesin modeli teyit etmek.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">1P+N ve 2P Sat\u0131n Alma S\u00fcre\u00e7lerinde S\u0131k G\u00f6r\u00fclen Hatalar<\/h2>\n\n\n<h3 class=\"wp-block-heading\">Her 1P+N tipi kesicinin ayn\u0131 i\u00e7 mimariye sahip oldu\u011fu varsay\u0131m\u0131yla<\/h3>\n<p class=\"wp-block-paragraph\">\u00dcreticilerin \u00f6rnekleri birbirine benzeyebilir, ancak ilgili modelin belgeleri mutlaka kontrol edilmelidir.<\/p>\n\n<h3 class=\"wp-block-heading\">Her 2P kesicinin faz + n\u00f6tr oldu\u011funu varsayarsak<\/h3>\n<p class=\"wp-block-paragraph\">\u0130ki kutuplu bir tan\u0131mlama, tek ba\u015f\u0131na her elektrik sistemi i\u00e7in gerekli iletken atamalar\u0131n\u0131 belirlemez.<\/p>\n\n<h3 class=\"wp-block-heading\">Direk Say\u0131s\u0131n\u0131 Bir G\u00fcvenlik S\u0131ralamas\u0131 Olarak De\u011ferlendirme<\/h3>\n<p class=\"wp-block-paragraph\">2P, otomatik olarak \u201cdaha g\u00fcvenli\u201d de\u011fildir ve direk say\u0131s\u0131, evrensel bir kalite s\u0131ralamas\u0131 de\u011fildir. Do\u011fru konfig\u00fcrasyon, elektrik tasar\u0131m\u0131na ve ge\u00e7erli gerekliliklere ba\u011fl\u0131d\u0131r.<\/p>\n\n<h3 class=\"wp-block-heading\">1P+N\u2019nin Her Zaman Daha K\u00fc\u00e7\u00fck Oldu\u011funu Varsayarsak<\/h3>\n<p class=\"wp-block-paragraph\">Baz\u0131 \u00fcr\u00fcn gruplar\u0131nda kompakt tasar\u0131mlar kullan\u0131l\u0131r; ancak mod\u00fcl geni\u015fli\u011fi, kesin boyut bilgilerine g\u00f6re do\u011frulanmal\u0131d\u0131r.<\/p>\n\n<h3 class=\"wp-block-heading\">Bir G\u00f6r\u00fcnt\u00fcden N\u00f6tr Davran\u0131\u015f\u0131 Tahmin Etme<\/h3>\n<p class=\"wp-block-paragraph\">Bir foto\u011fraf, u\u00e7 say\u0131s\u0131n\u0131 ve fiziksel yap\u0131y\u0131 g\u00f6sterebilir; ancak i\u00e7 elektriksel davran\u0131\u015f, bir yapay zeka g\u00f6r\u00fcnt\u00fcs\u00fcnden veya \u00fcr\u00fcn foto\u011fraf\u0131ndan de\u011fil, teknik belgelerden elde edilmelidir.<\/p>\n\n\n<h2 class=\"wp-block-heading\">Bir MCB Teklif Talebinde Neler Bulunmal\u0131d\u0131r?<\/h2>\n\n\n<p class=\"wp-block-paragraph\">\u015eunu kullan\u0131n: <a href=\"https:\/\/ritoks.com\/tr\/ac-mcb-rfq-checklist\/\">AC MCB Teklif Talebi Kontrol Listesi<\/a> Daha net bir sorgulama i\u00e7in l\u00fctfen a\u015fa\u011f\u0131dakileri sa\u011flay\u0131n:<\/p>\n\n<ul class=\"wp-block-list\"><li>Sistem gerilimi<\/li>\n<li>Ak\u0131m de\u011feri<\/li>\n<li>Gerekli direk d\u00fczeni<\/li>\n<li>Gerekli hareket e\u011frisi<\/li>\n<li>Gerekli kopma kapasitesi<\/li>\n<li>Miktar ve kullan\u0131m<\/li>\n<li>Gerekli montaj bi\u00e7imi<\/li>\n<li>Gerekli \u00fcr\u00fcn belgeleri<\/li><\/ul>\n\n\n<p class=\"wp-block-paragraph\">Proje a\u00e7\u0131s\u0131ndan n\u00f6tr hatt\u0131n\u0131n do\u011fru \u00e7al\u0131\u015fmas\u0131 \u00f6nemliyse, tedarik\u00e7iden n\u00f6tr hatt\u0131n\u0131n devreye al\u0131n\u0131p al\u0131nmad\u0131\u011f\u0131n\u0131, korunup korunmad\u0131\u011f\u0131n\u0131, ilgili t\u00fcm devre d\u00fczenlemelerini, kesin ba\u011flant\u0131 \u015femas\u0131n\u0131 ve kesin model belgelerini a\u00e7\u0131k\u00e7a teyit etmesini isteyin. Bu hususlar\u0131 varsay\u0131ma b\u0131rakmay\u0131n.<\/p><\/div>\n\n\n\n<div class=\"wp-block-group alignfull has-ast-global-color-5-background-color has-background is-layout-constrained wp-container-core-group-is-layout-bc87fa27 wp-block-group-is-layout-constrained\" style=\"padding-top:56px;padding-right:24px;padding-bottom:56px;padding-left:24px\">\n<h2 class=\"wp-block-heading\" id=\"faq\">S\u0131k Sorulan Sorular<\/h2>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>1P+N ve 2P devre kesiciler aras\u0131ndaki temel fark nedir?<\/summary><p class=\"wp-block-paragraph\">Bunlar farkl\u0131 kutup veya konfig\u00fcrasyon tan\u0131mlamalar\u0131d\u0131r. Korunan kutuplar, n\u00f6tr devre kesme ve i\u00e7 \u00e7al\u0131\u015fma a\u00e7\u0131s\u0131ndan tam olarak ne gibi farkl\u0131l\u0131klar oldu\u011fu, ilgili \u00fcr\u00fcn belgelerinden teyit edilmelidir.<\/p><\/details>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>1P+N her zaman bir korumal\u0131 faz ve bir anahtarlamal\u0131 n\u00f6tr anlam\u0131na gelir mi?<\/summary><p class=\"wp-block-paragraph\">Bu, genel bir varsay\u0131m de\u011fildir. ABB ve Schneider, bu t\u00fcr belgelenmi\u015f bir d\u00fczenlemeye sahip \u00f6zel 1P+N \u00fcr\u00fcnleri piyasaya s\u00fcrmektedir; ancak ba\u015fka bir \u00fcreticinin kesicisi i\u00e7in ayr\u0131 olarak teyit al\u0131nmas\u0131 gerekir.<\/p><\/details>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>2P, her zaman her iki kutbun da korundu\u011fu anlam\u0131na m\u0131 gelir?<\/summary><p class=\"wp-block-paragraph\">Hager ve Eaton markalar\u0131na ait baz\u0131 belirli 2P MCB\u2019lerde iki korunan kutup a\u00e7\u0131k\u00e7a belirtilmi\u015ftir; ancak bu bilgi, modele \u00f6zg\u00fc kan\u0131tlar olmadan her 2P \u00fcr\u00fcn\u00fcne genelle\u015ftirilmemelidir.<\/p><\/details>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>2P, 1P+N\u2019den daha m\u0131 iyidir?<\/summary><p class=\"wp-block-paragraph\">Do\u011fas\u0131 gere\u011fi de\u011fil. Bunlar farkl\u0131 konfig\u00fcrasyonlard\u0131r. Do\u011fru se\u00e7im, proje gereksinimlerine ve s\u00f6z konusu kesicinin belgelenmi\u015f davran\u0131\u015f\u0131na ba\u011fl\u0131d\u0131r.<\/p><\/details>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>1P+N her zaman bir DIN mod\u00fcl\u00fc geni\u015fli\u011finde midir?<\/summary><p class=\"wp-block-paragraph\">Yaln\u0131zca konfig\u00fcrasyon ad\u0131ndan yola \u00e7\u0131karak genel bir sonuca var\u0131lmamal\u0131d\u0131r. \u00dcr\u00fcn geni\u015fli\u011fi, \u00fcreticinin boyut bilgilerine g\u00f6re kontrol edilmelidir.<\/p><\/details>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>RITOKS, hem 1P+N hem de 2P tipinde MCB\u2019ler sunuyor mu?<\/summary><p class=\"wp-block-paragraph\">Evet, belirli \u00fcr\u00fcn serilerinde. RTSXD01 ve RTSXD04 modelleri hem 1P+N hem de 2P se\u00e7eneklerini sunar. RTSXD02 ve RTSXD03 modelleri 1P+N se\u00e7eneklerini sunarken, RTS-ACM60 ve RTS-AC47 modelleri mevcut konfig\u00fcrasyonlar\u0131 aras\u0131nda 2P se\u00e7ene\u011fini sunar.<\/p><\/details>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Mevcut RITOKS \u00fcr\u00fcn sayfalar\u0131ndan n\u00f6tr anahtarlama \u00f6zelli\u011fini tespit edebilir miyim?<\/summary><p class=\"wp-block-paragraph\">\u0130ncelenen modeller i\u00e7in ge\u00e7erli de\u011fildir. Mevcut \u00fcr\u00fcn sayfalar\u0131, konfig\u00fcrasyon se\u00e7eneklerinin mevcut oldu\u011funu teyit etmekte ancak tarafs\u0131z anahtarlama veya koruma davran\u0131\u015f\u0131n\u0131 tan\u0131mlamak i\u00e7in yeterli model \u00f6zelinde bilgi sunmamaktad\u0131r.<\/p><\/details>\n<\/div>\n\n\n\n<div class=\"wp-block-group alignfull has-ast-global-color-5-color has-ast-global-color-0-background-color has-text-color has-background is-layout-constrained wp-container-core-group-is-layout-bc87fa27 wp-block-group-is-layout-constrained\" style=\"padding-top:56px;padding-right:24px;padding-bottom:56px;padding-left:24px\">\n<h2 class=\"wp-block-heading has-ast-global-color-5-color has-text-color\">MCB yap\u0131land\u0131rmas\u0131n\u0131 do\u011frulamak i\u00e7in yard\u0131ma m\u0131 ihtiyac\u0131n\u0131z var?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Bir AC minyat\u00fcr devre kesici se\u00e7erken, konfig\u00fcrasyon etiketi teknik \u00f6zelliklerin yaln\u0131zca bir par\u00e7as\u0131d\u0131r. RITOKS, farkl\u0131 kutuplu konfig\u00fcrasyonlara, ak\u0131m de\u011ferlerine, B\/C\/D e\u011frisi se\u00e7eneklerine, kesme kapasitesi de\u011ferlerine ve montaj bi\u00e7imlerine sahip MCB serilerini piyasaya sunmaktad\u0131r.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">N\u00f6tr anahtarlama, korumal\u0131 kutup d\u00fczeni veya kesin i\u00e7 davran\u0131\u015f\u0131n \u00f6nemli oldu\u011fu projelerde, bu gereklilikleri do\u011frudan teklif talebine dahil edin; b\u00f6ylece se\u00e7im yap\u0131lmadan \u00f6nce do\u011fru modelin do\u011frulanmas\u0131 sa\u011flanabilir.<\/p>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-ast-global-color-0-color has-ast-global-color-5-background-color has-text-color has-background wp-element-button\" href=\"https:\/\/ritoks.com\/tr\/contact-us\/\" style=\"border-radius:6px\">Fiyat Teklifi \u0130steyin<\/a><\/div>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>1P+N vs 2P Circuit Breakers: Configuration Questions for Buyers When buyers compare 1P+N and 2P circuit breakers, the first difference [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"no-sidebar","site-content-layout":"page-builder","ast-site-content-layout":"full-width-container","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"disabled","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ritoks_resource_detail_renderer":null,"ritoks_resource_product_cat_term_id":0,"footnotes":""},"categories":[64],"tags":[],"class_list":["post-715","post","type-post","status-publish","format-standard","hentry","category-circuit-protection"],"acf":[],"spectra_blocks_featured_image_url":null,"spectra_blocks_author_info":{"display_name":"RITOKS","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/6d7d0fc73468198f994ab13ef6eb6558c53b6ed1ad86364d5165efe8bdf8eb4a?s=96&d=mm&r=g","author_link":"https:\/\/ritoks.com\/tr\/author\/dazzlingwqbgmail-com\/","description":""},"_links":{"self":[{"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/posts\/715","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/comments?post=715"}],"version-history":[{"count":4,"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/posts\/715\/revisions"}],"predecessor-version":[{"id":733,"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/posts\/715\/revisions\/733"}],"wp:attachment":[{"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/media?parent=715"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/categories?post=715"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ritoks.com\/tr\/wp-json\/wp\/v2\/tags?post=715"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}