Запитати зараз
RITOKS RTX-TOR36 thermal overload relay with adjustable setting dial on a white background

Industrial Power Switching · RTX-TOR36

RTX-TOR36 Thermal Overload Relays 1A-160A

Adjustable thermal overload relays for three-phase motor protection, with 13 setting bands from 1A to 160A across three frame sizes.

Setting range1A–160A, 13 bands

НапругаUp to 690V

КонфігураціяFrame mapping to confirm

СертифікаціяCCC

Огляд продукту

RTX-TOR36 relays pair with contactors to trip a motor circuit on sustained overload. Each band has an adjustable current dial. Choose the band so the motor full-load current sits within the setting range.

Основні особливості

  • 13 adjustable current bands
  • Frame mapping confirmed at order
  • Rated up to 690V
  • CCC supplier-listed

Доступні моделі / конфігурації

Use these RITOKS configuration references for enquiry; confirm the exact specification before ordering.

Довідка RITOKSSetting rangeКонфігурація
RTX-TOR36-1-161–1.6 AConfirm with RITOKS before ordering
RTX-TOR36-15-241.5–2.4 AConfirm with RITOKS before ordering
RTX-TOR36-22-352.2–3.5 AConfirm with RITOKS before ordering
RTX-TOR36-32-53.2–5 AConfirm with RITOKS before ordering
RTX-TOR36-45-724.5–7.2 AConfirm with RITOKS before ordering
RTX-TOR36-68-116.8–11 AConfirm with RITOKS before ordering
RTX-TOR36-10-1610–16 AConfirm with RITOKS before ordering
RTX-TOR36-14-2214–22 AConfirm with RITOKS before ordering
RTX-TOR36-28-4528–45 AConfirm with RITOKS before ordering
RTX-TOR36-40-6340–63 AConfirm with RITOKS before ordering
RTX-TOR36-53-8553–85 AConfirm with RITOKS before ordering
RTX-TOR36-75-12075–120 AConfirm with RITOKS before ordering
RTX-TOR36-100-160100–160 AConfirm with RITOKS before ordering

Технічні характеристики

Тип товаруРеле теплового перевантаження
Setting bands1–1.6, 1.5–2.4, 2.2–3.5, 3.2–5, 4.5–7.2, 6.8–11, 10–16, 14–22, 28–45, 40–63, 53–85, 75–120, 100–160 A
Frame mappingNot published; confirm with ritoks before ordering
Номінальна напругаUp to 690V
СертифікаціяCCC (supplier-listed)
Trip class and auxiliary contactsNot published; confirm with ritoks before ordering

Застосування

AI-generated conceptual application context. Confirm equipment fit, installation conditions and circuit requirements for the selected configuration.

AI-generated scene of a technician adjusting a thermal overload relay below a contactor

Motor starter panels

Combine with an AC contactor to build direct-on-line starters.

Compressor and pump motors

Protect three-phase motors against sustained overload.

Conveyor drives

Set the dial to motor full-load current on each conveyor drive.

Інформація, яку необхідно підтвердити для відбору

  • Струм двигуна при повному навантаженні
  • Contactor model and mounting
  • Trip class and reset mode
  • Auxiliary contact and quantity needs

Часті запитання

How do I choose a setting band?

Choose a band whose range contains the motor full-load current, then set the dial to that value.

Which contactors does it fit?

Mounting compatibility is not published. Confirm the contactor model before ordering.