Motor Protection Circuit Breakers · RTX-MP20
RTX-MP20 IP66 Enclosed Motor Protection Circuit Breakers 0.4A-20A
Three-pole motor protection circuit breakers supplied inside an IP66 waterproof enclosure, with thirteen adjustable current bands from 0.4A to 20A at AC380V.
額定電壓AC380V
Setting range0.4A–20A, 13 bands
附件IP66 waterproof box
樁3P
產品概覽
RTX-MP20 combines a three-pole motor protection breaker with a waterproof IP66 enclosure, so it can be installed directly beside pumps, fans and small motors without a separate control panel. Choose the setting band that brackets the motor full-load current. An empty enclosure is also available for fitting an existing breaker.
主要特色
- 3P motor protection breaker in an IP66 box
- Thirteen setting bands from 0.4A to 20A
- Rotary operation through the enclosure
- Empty enclosure option; CE supplier-listed
可選型號/規格
Use these RITOKS configuration references for enquiry; confirm the exact specification before ordering.
| RITOKS 參考資料 | Setting range | 樁 | 額定電壓 | 附件 |
|---|---|---|---|---|
| RTX-MP20-0.63 | 0.4–0.63A | 3P | AC380V | IP66 |
| RTX-MP20-1 | 0.63–1A | 3P | AC380V | IP66 |
| RTX-MP20-1.6 | 1–1.6A | 3P | AC380V | IP66 |
| RTX-MP20-2.5 | 1.6–2.5A | 3P | AC380V | IP66 |
| RTX-MP20-3.2 | 2–3.2A | 3P | AC380V | IP66 |
| RTX-MP20-4 | 2.5–4A | 3P | AC380V | IP66 |
| RTX-MP20-5 | 3.2–5A | 3P | AC380V | IP66 |
| RTX-MP20-6.3 | 4–6.3A | 3P | AC380V | IP66 |
| RTX-MP20-8 | 5–8A | 3P | AC380V | IP66 |
| RTX-MP20-10 | 6.3–10A | 3P | AC380V | IP66 |
| RTX-MP20-12.5 | 8–12.5A | 3P | AC380V | IP66 |
| RTX-MP20-16 | 10–16A | 3P | AC380V | IP66 |
| RTX-MP20-20 | 14–20A | 3P | AC380V | IP66 |
| RTX-MP20-BOX | Enclosure only | 3P breaker space | — | IP66 |
技術規格
| 產品類型 | Enclosed motor protection circuit breaker |
|---|---|
| 樁 | 3P |
| Setting ranges | 0.4A to 20A in 13 bands |
| 額定電壓 | AC380V |
| 頻率 | 50Hz (product label) |
| 外殼防護等級 | IP66 |
| 破裂載荷 | Supplier-listed value 6; unit and test condition to confirm |
| 認證 | CE (supplier-listed) |
| Trip class and cable entries | Confirm with RITOKS before ordering |
應用
AI-generated conceptual application context. Confirm equipment fit, installation conditions and circuit requirements for the selected configuration.

Irrigation and water pumps
Install the IP66 box at the pump house wall to protect and isolate the motor locally.
Ventilation fans
Protect exhaust and supply fan motors on roofs or plant rooms exposed to rain and washdown.
Small conveyors and mixers
Provide local motor protection on machines without a dedicated control cabinet.
選定前需確認的資訊
- Motor full-load current and setting band
- Supply voltage and motor starting conditions
- Installation environment, sunlight and temperature
- Cable diameter, gland quantity and quantity of units
常見問題
How do I choose the setting band?
Pick the band whose range includes the motor full-load current from the nameplate, then set the dial to that value.
What breaking capacity does RTX-MP20 have?
The supplier lists the value 6 without a unit or test condition. Confirm the rating before use on circuits with high fault levels.
索取報價
請提供確切的型號、所需額定值、數量及目的地。我們將在報價前確認庫存狀況及所需文件。.