RTX-MP20 IP66 Enclosed Motor Protection Circuit Breakers 0.4A-20A

Three-pole motor protection circuit breakers supplied inside an IP66 waterproof enclosure, with thirteen adjustable current bands from 0.4A to 20A at AC380V.

額定電壓AC380V

Setting range0.4A–20A, 13 bands

附件IP66 waterproof box

樁3P

產品概覽

RTX-MP20 combines a three-pole motor protection breaker with a waterproof IP66 enclosure, so it can be installed directly beside pumps, fans and small motors without a separate control panel. Choose the setting band that brackets the motor full-load current. An empty enclosure is also available for fitting an existing breaker.

主要特色

  • 3P motor protection breaker in an IP66 box
  • Thirteen setting bands from 0.4A to 20A
  • Rotary operation through the enclosure
  • Empty enclosure option; CE supplier-listed

可選型號/規格

Use these RITOKS configuration references for enquiry; confirm the exact specification before ordering.

RITOKS 參考資料Setting range樁額定電壓附件
RTX-MP20-0.630.4–0.63A3PAC380VIP66
RTX-MP20-10.63–1A3PAC380VIP66
RTX-MP20-1.61–1.6A3PAC380VIP66
RTX-MP20-2.51.6–2.5A3PAC380VIP66
RTX-MP20-3.22–3.2A3PAC380VIP66
RTX-MP20-42.5–4A3PAC380VIP66
RTX-MP20-53.2–5A3PAC380VIP66
RTX-MP20-6.34–6.3A3PAC380VIP66
RTX-MP20-85–8A3PAC380VIP66
RTX-MP20-106.3–10A3PAC380VIP66
RTX-MP20-12.58–12.5A3PAC380VIP66
RTX-MP20-1610–16A3PAC380VIP66
RTX-MP20-2014–20A3PAC380VIP66
RTX-MP20-BOXEnclosure only3P breaker space—IP66

技術規格

產品類型Enclosed motor protection circuit breaker
樁3P
Setting ranges0.4A to 20A in 13 bands
額定電壓AC380V
頻率50Hz (product label)
外殼防護等級IP66
破裂載荷Supplier-listed value 6; unit and test condition to confirm
認證CE (supplier-listed)
Trip class and cable entriesConfirm with RITOKS before ordering

應用

AI-generated conceptual application context. Confirm equipment fit, installation conditions and circuit requirements for the selected configuration.

AI-generated scene of an IP66 enclosed motor protection breaker wall-mounted beside an irrigation pump motor

Irrigation and water pumps

Install the IP66 box at the pump house wall to protect and isolate the motor locally.

Ventilation fans

Protect exhaust and supply fan motors on roofs or plant rooms exposed to rain and washdown.

Small conveyors and mixers

Provide local motor protection on machines without a dedicated control cabinet.

選定前需確認的資訊

  • Motor full-load current and setting band
  • Supply voltage and motor starting conditions
  • Installation environment, sunlight and temperature
  • Cable diameter, gland quantity and quantity of units

常見問題

How do I choose the setting band?

Pick the band whose range includes the motor full-load current from the nameplate, then set the dial to that value.

What breaking capacity does RTX-MP20 have?

The supplier lists the value 6 without a unit or test condition. Confirm the rating before use on circuits with high fault levels.