Fuses and Fuse Switches · NH 3P BS
NH 3-Pole Fuse Switch Disconnectors
Three-pole NH fuse switch disconnectors for NH000 through NH3 fuse-link sizes. The fuse links are separate components and must be selected for the circuit.
NH000–NH3Switch sizes
160–630ARange current
690VRated voltage
3PPole arrangement
Product Overview
The BS range covers board-mounted NH sizes 000 through 3 and a size 00 option for 60 mm busbar mounting. Switch ratings and matching fuse-link characteristics must be considered separately.
Key Features
- NH000 to NH3 range
- 3-pole construction
- Board-fixing and 60 mm busbar option
- IP20 contact protection
- Test holes in fuse-link covers
Available Models / Configurations
Supplier-listed family information; confirm the exact orderable RITOKS configuration.
| NH size | Rated current | Connection | Reference |
|---|---|---|---|
| NH000 | 160 A | Clamp | 335005 |
| NH00 | 160 A | Screw / clamp | 335025 |
| NH00 busbar | 160 A | 60 mm busbar | 335040 |
| NH1 | 250 A | Screw | 335095 |
| NH2 | 400 A | Screw | 335155 |
| NH3 | 630 A | Screw | 335195 |
Technical Specifications
| Product type | Three-pole NH fuse switch disconnector |
|---|---|
| Rated voltage | 690 V |
| Rated current | 160–630 A by size |
| Fuse sizes | NH000 / NH00 / NH1 / NH2 / NH3 |
| Utilization category | AC-22B / AC-23B; DC-21B / DC-22B |
| Contact protection | IP20 |
| Impulse withstand voltage | 8 kV Uimp |
| Reference standards | IEC/EN 60947-1; IEC/EN 60947-3 |
Applications
Illustrative panel environments; confirm equipment fit and circuit requirements for the selected model.

Distribution Switchboards
Fused feeder isolation with the correct NH link.
Industrial Panels
Size selection to match current and mounting.
Busbar Systems
NH00 60 mm busbar configuration where specified.
Information to Confirm for Selection
- NH size and exact switch reference
- Required fuse-link class and current
- Board or 60 mm busbar mounting
- Utilization category and voltage
- Handle arrangement and matching link datasheet
FAQ
Are NH fuse links included in the switch rating?
No. The switch disconnector and fuse links are separate components with separate selection data.
What sizes are published?
The manufacturer lists NH000, NH00, NH1, NH2 and NH3, plus a size 00 busbar reference.
Is a 60 mm busbar version listed?
Yes. Reference 335040 is listed for an NH00 busbar configuration.
Request a Quote
Send the exact model, required ratings, quantity and destination. We will confirm availability and documentation before quotation.
Please include: NH size and exact switch reference; Required fuse-link class and current; Board or 60 mm busbar mounting.