DC Surge Protective Devices · RTS-SPD60-1000-2P
2P DC PV Surge Protective Device, 20-60kA, 500-1000V
Compact 2-pole DC surge protective device family for photovoltaic protection circuits, available in DC500V to DC1000V versions with 20kA, 40kA and 60kA maximum discharge-current options.
- 2P configurations for DC500V, 600V, 800V and 1000V circuits
- 20kA, 40kA and 60kA maximum discharge-current options
- Remote signalling version is listed; contact data requires confirmation
Technical Parameters
| Model Family | RTS-SPD60-1000-2P |
| Product Type | 2P DC Photovoltaic Surge Protective Device |
| Maximum Continuous Operating Voltage | DC500V / 600V / 800V / 1000V |
| Nominal Discharge Current (In) | 10kA / 20kA / 30kA, subject to selected variant |
| Maximum Discharge Current (Imax) | 20kA / 40kA / 60kA |
| Pole Configuration | 2P |
| Remote Signalling | Listed option; terminal and contact ratings pending verification |
| SPD Classification / Up / Iscpv | Pending verified datasheet and test report |
| Standards / Certifications | Pending verified supplier documents |
Available Models
| Ritoks Model | Ucpv | Poles | In / Imax |
|---|---|---|---|
| RTS-SPD20-500-2P | DC500V | 2P | 10 / 20kA |
| RTS-SPD40-500-2P-R | DC500V | 2P | 20 / 40kA |
| RTS-SPD40-600-2P-R | DC600V | 2P | 20 / 40kA |
| RTS-SPD40-800-2P-R | DC800V | 2P | 20 / 40kA |
| RTS-SPD40-1000-2P-R | DC1000V | 2P | 20 / 40kA |
| RTS-SPD60-500-2P-R | DC500V | 2P | Supplier sheet inconsistency; confirm / 60kA |
| RTS-SPD60-600-2P-R | DC600V | 2P | 30 / 60kA |
| RTS-SPD60-800-2P-R | DC800V | 2P | 30 / 60kA |
| RTS-SPD60-1000-2P-R | DC1000V | 2P | 30 / 60kA |
The supplied table contains an inconsistent nominal-discharge-current value for the DC500V 60kA row. Confirm that SKU with the supplier before quotation or publication of a final datasheet.
Applications
- PV combiner boxes and array junction boxes
- Solar inverter DC input protection
- Compact photovoltaic distribution panels
- Industrial DC control cabinets requiring surge indication
FAQ
What information is needed to select the correct model?
Provide the maximum continuous DC voltage, required In and Imax values, circuit diagram, remote-signal requirement and installation quantity.
Is the remote signalling contact rating confirmed?
No. The source listing indicates a remote signalling version, but the terminal type and contact ratings require a verified wiring diagram or datasheet.
Need Help Selecting a DC Surge Protector?
Send the maximum system voltage, required In and Imax values, remote-signal requirement, quantity and destination country. We will confirm the matching variant before quotation.