استفسر الآن
RITOKS RTX-TOR36 thermal overload relay with adjustable setting dial on a white background

Industrial Power Switching · RTX-TOR36

RTX-TOR36 Thermal Overload Relays 1A-160A

Adjustable thermal overload relays for three-phase motor protection, with 13 setting bands from 1A to 160A across three frame sizes.

Setting range1A–160A, 13 bands

الجهد الكهربائيUp to 690V

الإعداداتFrame mapping to confirm

الشهادةCCC

نظرة عامة على المنتج

RTX-TOR36 relays pair with contactors to trip a motor circuit on sustained overload. Each band has an adjustable current dial. Choose the band so the motor full-load current sits within the setting range.

الميزات الرئيسية

  • 13 adjustable current bands
  • Frame mapping confirmed at order
  • Rated up to 690V
  • CCC supplier-listed

الطرازات / التكوينات المتوفرة

Use these RITOKS configuration references for enquiry; confirm the exact specification before ordering.

مرجع RITOKSSetting rangeالإعدادات
RTX-TOR36-1-161–1.6 AConfirm with RITOKS before ordering
RTX-TOR36-15-241.5–2.4 AConfirm with RITOKS before ordering
RTX-TOR36-22-352.2–3.5 AConfirm with RITOKS before ordering
RTX-TOR36-32-53.2–5 AConfirm with RITOKS before ordering
RTX-TOR36-45-724.5–7.2 AConfirm with RITOKS before ordering
RTX-TOR36-68-116.8–11 AConfirm with RITOKS before ordering
RTX-TOR36-10-1610–16 AConfirm with RITOKS before ordering
RTX-TOR36-14-2214–22 AConfirm with RITOKS before ordering
RTX-TOR36-28-4528–45 AConfirm with RITOKS before ordering
RTX-TOR36-40-6340–63 AConfirm with RITOKS before ordering
RTX-TOR36-53-8553–85 AConfirm with RITOKS before ordering
RTX-TOR36-75-12075–120 AConfirm with RITOKS before ordering
RTX-TOR36-100-160100–160 AConfirm with RITOKS before ordering

المواصفات الفنية

نوع المنتجمرحل الحمل الزائد الحراري
Setting bands1–1.6, 1.5–2.4, 2.2–3.5, 3.2–5, 4.5–7.2, 6.8–11, 10–16, 14–22, 28–45, 40–63, 53–85, 75–120, 100–160 A
Frame mappingNot published; confirm with ritoks before ordering
الجهد المقننUp to 690V
الشهادةCCC (supplier-listed)
Trip class and auxiliary contactsNot published; confirm with ritoks before ordering

التطبيقات

AI-generated conceptual application context. Confirm equipment fit, installation conditions and circuit requirements for the selected configuration.

AI-generated scene of a technician adjusting a thermal overload relay below a contactor

Motor starter panels

Combine with an AC contactor to build direct-on-line starters.

Compressor and pump motors

Protect three-phase motors against sustained overload.

Conveyor drives

Set the dial to motor full-load current on each conveyor drive.

المعلومات التي يجب التأكد منها عند الاختيار

  • تيار المحرك عند الحمل الكامل
  • Contactor model and mounting
  • Trip class and reset mode
  • Auxiliary contact and quantity needs

الأسئلة الشائعة

How do I choose a setting band?

Choose a band whose range contains the motor full-load current, then set the dial to that value.

Which contactors does it fit?

Mounting compatibility is not published. Confirm the contactor model before ordering.

اطلب عرض أسعار

يرجى إرسال الطراز الدقيق، والقيم التصنيفية المطلوبة، والكمية، والوجهة. وسنقوم بالتحقق من التوافر والمستندات اللازمة قبل تقديم عرض الأسعار.

طلب معلومات عن المنتج والأسعار

يرجى إرسال أرقام الطرازات، والقدرات، والكميات، وتفاصيل الوجهة. وسنقوم بالتحقق من توفر المنتجات قبل إعداد عرض الأسعار.

الرجوع إلى الأعلى