استفسر الآن
Sixteen-channel PLC relay interface module on a white background, representative family view

Industrial Power Switching · RTX-PIM

PLC Relay Interface Modules

Multi-channel relay interfaces for hardwired PLC and controller outputs. Choose the channel count and DC coil voltage to match the control circuit.

2–32Even-numbered channels

5 / 12 / 24 V DCخيارات الملفات

1 مفتوح + 1 مغلقPer-channel contact form

35 mmالتركيب على سكة DIN

نظرة عامة على المنتج

These interfaces place changeover relay contacts between compatible controller outputs and separately selected loads. Each channel has an LED indication and terminal connections. This is a hardwired relay interface, not a Modbus remote I/O device. The photograph represents a 16-channel, 24 V DC configuration; other channel counts have different lengths.

الميزات الرئيسية

  • Even-numbered channel counts from 2 to 32
  • Separate DC coil-voltage configurations
  • One changeover contact per channel
  • Channel-level LED indication
  • 35 mm DIN-rail installation

الطرازات / التكوينات المتوفرة

Use these configuration references for enquiry; confirm the exact specification before ordering.

RITOKS configuration referenceالقنواتDC coil optionsPublished L × W × H
RTX-PIM0445 / 12 / 24 V51 × 88 × 56 mm
RTX-PIM0885 / 12 / 24 V70 × 88 × 56 mm
RTX-PIM16165 / 12 / 24 V137 × 88 × 56 mm
RTX-PIM32325 / 12 / 24 V271 × 88 × 56 mm

المواصفات الفنية

العمارةHardwired multi-channel relay interface
Channel range2–32, even-numbered configurations
Nominal coil voltages5 / 12 / 24 V DC; separate versions
Contact arrangementSPDT: 1NO + 1NC per channel
الاستطبابSeparate LED indication for each group
التركيب35 mm U / E DIN rail
Conductor cross-section0.2–2.5 mm²
Wire stripping length6–8 mm

التطبيقات

AI-generated conceptual application context, not a photograph of an actual installation.

Illustrative conveyor control cabinet with switching components; not an exact installation of the offered module

Machine Control Panels

Interface compatible PLC digital outputs with separately rated contactor coils and auxiliary control loads. Confirm output polarity and suppression before wiring.

Conveyor Control Circuits

Group several hardwired switching channels in one panel location. Channel count and contact duty must match the machine circuit, not merely the photograph.

Controller Interface Retrofits

Replace an interface only after checking controller output type, coil voltage, terminal layout and cabinet clearance. Do not substitute it for a networked I/O module.

المعلومات التي يجب التأكد منها عند الاختيار

  • Required channel count and control voltage
  • Controller output type, polarity and wiring diagram
  • Load type, switching voltage, inrush and frequency
  • Exact relay contact rating and suppression requirements
  • Rail clearance, terminal arrangement, quantity and destination

الأسئلة الشائعة

Does this module provide RS485 Modbus communication?

No RS485 or Modbus function is established for this selected family. It is a hardwired relay interface.

Does every version look like the main image?

No. The image shows a 16-channel configuration. Channel count changes the assembly length.

What should I provide for selection?

Provide channel count, controller output type, coil voltage and the actual load duty. Confirm the exact contact-rating document before design-in.

اطلب عرض أسعار

يرجى إرسال الطراز الدقيق، والقيم التصنيفية المطلوبة، والكمية، والوجهة. وسنقوم بالتحقق من التوافر والمستندات اللازمة قبل تقديم عرض الأسعار.

Please include: Required channel count and control voltage; Controller output type, polarity and wiring diagram; Load type, switching voltage, inrush and frequency.

طلب معلومات عن المنتج والأسعار

يرجى إرسال أرقام الطرازات، والقدرات، والكميات، وتفاصيل الوجهة. وسنقوم بالتحقق من توفر المنتجات قبل إعداد عرض الأسعار.

الرجوع إلى الأعلى