Industrial Power Switching · RTX-PIM
PLC Relay Interface Modules
Multi-channel relay interfaces for hardwired PLC and controller outputs. Choose the channel count and DC coil voltage to match the control circuit.
2–32Even-numbered channels
5 / 12 / 24 V DCCác tùy chọn cuộn dây
1 tiếp điểm thường đóng (NO) + 1 tiếp điểm thường mở (NC)Per-channel contact form
35 mmLắp đặt trên thanh DIN
Tổng quan về sản phẩm
These interfaces place changeover relay contacts between compatible controller outputs and separately selected loads. Each channel has an LED indication and terminal connections. This is a hardwired relay interface, not a Modbus remote I/O device. The photograph represents a 16-channel, 24 V DC configuration; other channel counts have different lengths.
Các tính năng chính
- Even-numbered channel counts from 2 to 32
- Separate DC coil-voltage configurations
- One changeover contact per channel
- Channel-level LED indication
- 35 mm DIN-rail installation
Các mẫu / cấu hình có sẵn
Use these configuration references for enquiry; confirm the exact specification before ordering.
| RITOKS configuration reference | Kênh | DC coil options | Published L × W × H |
|---|---|---|---|
| RTX-PIM04 | 4 | 5 / 12 / 24 V | 51 × 88 × 56 mm |
| RTX-PIM08 | 8 | 5 / 12 / 24 V | 70 × 88 × 56 mm |
| RTX-PIM16 | 16 | 5 / 12 / 24 V | 137 × 88 × 56 mm |
| RTX-PIM32 | 32 | 5 / 12 / 24 V | 271 × 88 × 56 mm |
Thông số kỹ thuật
| Kiến trúc | Hardwired multi-channel relay interface |
|---|---|
| Channel range | 2–32, even-numbered configurations |
| Nominal coil voltages | 5 / 12 / 24 V DC; separate versions |
| Contact arrangement | SPDT: 1NO + 1NC per channel |
| Chỉ định | Separate LED indication for each group |
| Lắp đặt | 35 mm U / E DIN rail |
| Conductor cross-section | 0.2–2.5 mm² |
| Wire stripping length | 6–8 mm |
Ứng dụng
AI-generated conceptual application context, not a photograph of an actual installation.

Machine Control Panels
Interface compatible PLC digital outputs with separately rated contactor coils and auxiliary control loads. Confirm output polarity and suppression before wiring.
Conveyor Control Circuits
Group several hardwired switching channels in one panel location. Channel count and contact duty must match the machine circuit, not merely the photograph.
Controller Interface Retrofits
Replace an interface only after checking controller output type, coil voltage, terminal layout and cabinet clearance. Do not substitute it for a networked I/O module.
Thông tin cần xác nhận để tiến hành lựa chọn
- Required channel count and control voltage
- Controller output type, polarity and wiring diagram
- Load type, switching voltage, inrush and frequency
- Exact relay contact rating and suppression requirements
- Rail clearance, terminal arrangement, quantity and destination
Câu hỏi thường gặp
Does this module provide RS485 Modbus communication?
No RS485 or Modbus function is established for this selected family. It is a hardwired relay interface.
Does every version look like the main image?
No. The image shows a 16-channel configuration. Channel count changes the assembly length.
What should I provide for selection?
Provide channel count, controller output type, coil voltage and the actual load duty. Confirm the exact contact-rating document before design-in.
Yêu cầu báo giá
Vui lòng cung cấp thông tin chính xác về mẫu sản phẩm, thông số kỹ thuật yêu cầu, số lượng và địa điểm nhận hàng. Chúng tôi sẽ xác nhận tình trạng hàng có sẵn và các thủ tục giấy tờ trước khi gửi báo giá.
Please include: Required channel count and control voltage; Controller output type, polarity and wiring diagram; Load type, switching voltage, inrush and frequency.