Load Isolator Switches · RTX-HGL
RTX-HGL Panel-Mount Load Isolator Switches 125A-630A, 3P/4P
Open-type load isolator switches for mounting inside distribution panels, with a front operating handle, 3P or 4P poles, eight frame sizes from 125A to 630A and voltages up to 690V.
النطاق الحالي125A–630A, 8 sizes
الجهد المقننما يصل إلى 690 فولت تيار متردد
الأعمدة3P / 4P
التشغيلFront handle, panel mount
نظرة عامة على المنتج
RTX-HGL switches give a visible, lockable point of isolation on the incoming or outgoing feeders of a low-voltage distribution panel. They mount on the panel plate behind the door and are switched with a front handle, so the operator can cut power to a section before maintenance. The supplier's dimension table lists eight frame sizes from 125A to 630A in 3-pole and 4-pole versions, and the listing gives a rated voltage range up to 690V. Cables or busbars connect to bolted terminal posts. Overall width ranges from 140 mm for a 125A 3-pole unit to 290 mm for a 630A 4-pole unit. These are load-break isolators intended for infrequent switching, not for short-circuit protection, so they are used with an upstream breaker or fuses. For smaller rotary isolators up to 125A, see WOT and the enclosed RTX-LBS. The AC-21/AC-22/AC-23 operational currents, short-time withstand current and switching life of each size must be confirmed before ordering.
الميزات الرئيسية
- Eight frame sizes from 125A to 630A
- 3-pole and 4-pole versions in every size
- Rated voltage range up to 690V (supplier-listed)
- Bolted terminal posts for cable or busbar connection
الطرازات / التكوينات المتوفرة
Use these RITOKS configuration references for enquiry; confirm the exact specification before ordering.
| مرجع RITOKS | التيار المقنن | الأعمدة | Width × height (mm) |
|---|---|---|---|
| RTX-HGL-125/3 | 125A | 3P | 140 × 135 |
| RTX-HGL-125/4 | 125A | 4P | 170 × 135 |
| RTX-HGL-160/3 | 160A | 3P | 140 × 135 |
| RTX-HGL-160/4 | 160A | 4P | 170 × 135 |
| RTX-HGL-200/3 | 200A | 3P | 180 × 170 |
| RTX-HGL-200/4 | 200A | 4P | 230 × 170 |
| RTX-HGL-250/3 | 250A | 3P | 180 × 170 |
| RTX-HGL-250/4 | 250A | 4P | 230 × 170 |
| RTX-HGL-315/3 | 315A | 3P | 230 × 240 |
| RTX-HGL-315/4 | 315A | 4P | 290 × 240 |
| RTX-HGL-400/3 | 400A | 3P | 230 × 240 |
| RTX-HGL-400/4 | 400A | 4P | 290 × 240 |
| RTX-HGL-500/3 | 500A | 3P | 230 × 280 |
| RTX-HGL-500/4 | 500A | 4P | 290 × 280 |
| RTX-HGL-630/3 | 630A | 3P | 230 × 280 |
| RTX-HGL-630/4 | 630A | 4P | 290 × 280 |
المواصفات الفنية
| نوع المنتج | Load isolator switch, open type for panel mounting |
|---|---|
| نطاق التيار المقنن | 125A to 630A in eight frame sizes |
| الجهد المقنن | 0–690V AC range (supplier-listed) |
| الأعمدة | 3P or 4P |
| التشغيل | Front-operated handle |
| Terminal connection | Bolted terminal posts (supplier-listed) |
| Overall dimensions | 140 × 135 mm (125A 3P) to 290 × 280 mm (630A 4P), see model table |
| الوزن | Approx. 3.0 kg for 160A 3P (supplier-listed) |
| Utilisation category and operational current (AC-21/AC-22/AC-23) | Confirm with RITOKS before ordering |
| Rated short-time withstand current | Confirm with RITOKS before ordering |
| Mechanical and electrical life | Confirm with RITOKS before ordering |
| Padlocking and auxiliary contacts | Confirm with RITOKS before ordering |
التطبيقات
AI-generated conceptual application context. Confirm equipment fit, installation conditions and circuit requirements for the selected configuration.

Incoming feeder isolation
Isolate the main incoming supply of low-voltage switchboards and sub-distribution panels before maintenance work.
Outgoing feeder sections
Provide a manual disconnect point for outgoing feeders to production lines, compressors, chillers and large pump sets.
Generator and transfer panels
Separate generator or alternative supplies in changeover and backup power panels where a visible break is required.
المعلومات التي يجب التأكد منها عند الاختيار
- Rated current and number of poles (3P or 4P)
- Load type and required utilisation category (AC-21, AC-22 or AC-23)
- System voltage and prospective short-circuit current at the installation point
- Cable or busbar size and termination method
- Panel space available, using the width, height and hole spacing in the model table
- الكمية والوجهة
الأسئلة الشائعة
Can RTX-HGL switches break load current?
They are load isolator switches designed to make and break normal load current on infrequent operation. They are not short-circuit protection devices, so an upstream circuit breaker or fuses must protect the circuit. The exact utilisation category for each size should be confirmed before ordering.
When should I choose 4P instead of 3P?
Choose 4P when the neutral must be switched together with the phases, for example in some TN-S or generator changeover arrangements. Use 3P when the neutral is not switched.
How is RTX-HGL different from WOT and RTX-LBS?
WOT and RTX-LBS are rotary isolators for currents up to 125A, with RTX-LBS in an IP66 enclosure. RTX-HGL is an open panel-mounted switch for larger feeders from 125A to 630A.
اطلب عرض أسعار
يرجى إرسال الطراز الدقيق، والقيم التصنيفية المطلوبة، والكمية، والوجهة. وسنقوم بالتحقق من التوافر والمستندات اللازمة قبل تقديم عرض الأسعار.