Load Isolator Switches · RTX-HGL
RTX-HGL Panel-Mount Load Isolator Switches 125A-630A, 3P/4P
Open-type load isolator switches for mounting inside distribution panels, with a front operating handle, 3P or 4P poles, eight frame sizes from 125A to 630A and voltages up to 690V.
Current range125A–630A, 8 sizes
Rated voltageUp to 690V AC
Poles3P / 4P
OperationFront handle, panel mount
Product Overview
RTX-HGL switches give a visible, lockable point of isolation on the incoming or outgoing feeders of a low-voltage distribution panel. They mount on the panel plate behind the door and are switched with a front handle, so the operator can cut power to a section before maintenance. The supplier's dimension table lists eight frame sizes from 125A to 630A in 3-pole and 4-pole versions, and the listing gives a rated voltage range up to 690V. Cables or busbars connect to bolted terminal posts. Overall width ranges from 140 mm for a 125A 3-pole unit to 290 mm for a 630A 4-pole unit. These are load-break isolators intended for infrequent switching, not for short-circuit protection, so they are used with an upstream breaker or fuses. For smaller rotary isolators up to 125A, see WOT and the enclosed RTX-LBS. The AC-21/AC-22/AC-23 operational currents, short-time withstand current and switching life of each size must be confirmed before ordering.
Key Features
- Eight frame sizes from 125A to 630A
- 3-pole and 4-pole versions in every size
- Rated voltage range up to 690V (supplier-listed)
- Bolted terminal posts for cable or busbar connection
Available Models / Configurations
Use these RITOKS configuration references for enquiry; confirm the exact specification before ordering.
| RITOKS reference | Rated current | Poles | Width × height (mm) |
|---|---|---|---|
| RTX-HGL-125/3 | 125A | 3P | 140 × 135 |
| RTX-HGL-125/4 | 125A | 4P | 170 × 135 |
| RTX-HGL-160/3 | 160A | 3P | 140 × 135 |
| RTX-HGL-160/4 | 160A | 4P | 170 × 135 |
| RTX-HGL-200/3 | 200A | 3P | 180 × 170 |
| RTX-HGL-200/4 | 200A | 4P | 230 × 170 |
| RTX-HGL-250/3 | 250A | 3P | 180 × 170 |
| RTX-HGL-250/4 | 250A | 4P | 230 × 170 |
| RTX-HGL-315/3 | 315A | 3P | 230 × 240 |
| RTX-HGL-315/4 | 315A | 4P | 290 × 240 |
| RTX-HGL-400/3 | 400A | 3P | 230 × 240 |
| RTX-HGL-400/4 | 400A | 4P | 290 × 240 |
| RTX-HGL-500/3 | 500A | 3P | 230 × 280 |
| RTX-HGL-500/4 | 500A | 4P | 290 × 280 |
| RTX-HGL-630/3 | 630A | 3P | 230 × 280 |
| RTX-HGL-630/4 | 630A | 4P | 290 × 280 |
Technical Specifications
| Product type | Load isolator switch, open type for panel mounting |
|---|---|
| Rated current range | 125A to 630A in eight frame sizes |
| Rated voltage | 0–690V AC range (supplier-listed) |
| Poles | 3P or 4P |
| Operation | Front-operated handle |
| Terminal connection | Bolted terminal posts (supplier-listed) |
| Overall dimensions | 140 × 135 mm (125A 3P) to 290 × 280 mm (630A 4P), see model table |
| Weight | Approx. 3.0 kg for 160A 3P (supplier-listed) |
| Utilisation category and operational current (AC-21/AC-22/AC-23) | Confirm with RITOKS before ordering |
| Rated short-time withstand current | Confirm with RITOKS before ordering |
| Mechanical and electrical life | Confirm with RITOKS before ordering |
| Padlocking and auxiliary contacts | Confirm with RITOKS before ordering |
Applications
AI-generated conceptual application context. Confirm equipment fit, installation conditions and circuit requirements for the selected configuration.

Incoming feeder isolation
Isolate the main incoming supply of low-voltage switchboards and sub-distribution panels before maintenance work.
Outgoing feeder sections
Provide a manual disconnect point for outgoing feeders to production lines, compressors, chillers and large pump sets.
Generator and transfer panels
Separate generator or alternative supplies in changeover and backup power panels where a visible break is required.
Information to Confirm for Selection
- Rated current and number of poles (3P or 4P)
- Load type and required utilisation category (AC-21, AC-22 or AC-23)
- System voltage and prospective short-circuit current at the installation point
- Cable or busbar size and termination method
- Panel space available, using the width, height and hole spacing in the model table
- Quantity and destination
FAQ
Can RTX-HGL switches break load current?
They are load isolator switches designed to make and break normal load current on infrequent operation. They are not short-circuit protection devices, so an upstream circuit breaker or fuses must protect the circuit. The exact utilisation category for each size should be confirmed before ordering.
When should I choose 4P instead of 3P?
Choose 4P when the neutral must be switched together with the phases, for example in some TN-S or generator changeover arrangements. Use 3P when the neutral is not switched.
How is RTX-HGL different from WOT and RTX-LBS?
WOT and RTX-LBS are rotary isolators for currents up to 125A, with RTX-LBS in an IP66 enclosure. RTX-HGL is an open panel-mounted switch for larger feeders from 125A to 630A.
Request a Quote
Send the exact model, required ratings, quantity and destination. We will confirm availability and documentation before quotation.