Load Isolator Switches · RTX-HGL

RTX-HGL Panel-Mount Load Isolator Switches 125A-630A, 3P/4P

Open-type load isolator switches for mounting inside distribution panels, with a front operating handle, 3P or 4P poles, eight frame sizes from 125A to 630A and voltages up to 690V.

Current range125A–630A, 8 sizes

Rated voltageUp to 690V AC

Poles3P / 4P

OperationFront handle, panel mount

Product Overview

RTX-HGL switches give a visible, lockable point of isolation on the incoming or outgoing feeders of a low-voltage distribution panel. They mount on the panel plate behind the door and are switched with a front handle, so the operator can cut power to a section before maintenance. The supplier's dimension table lists eight frame sizes from 125A to 630A in 3-pole and 4-pole versions, and the listing gives a rated voltage range up to 690V. Cables or busbars connect to bolted terminal posts. Overall width ranges from 140 mm for a 125A 3-pole unit to 290 mm for a 630A 4-pole unit. These are load-break isolators intended for infrequent switching, not for short-circuit protection, so they are used with an upstream breaker or fuses. For smaller rotary isolators up to 125A, see WOT and the enclosed RTX-LBS. The AC-21/AC-22/AC-23 operational currents, short-time withstand current and switching life of each size must be confirmed before ordering.

Key Features

  • Eight frame sizes from 125A to 630A
  • 3-pole and 4-pole versions in every size
  • Rated voltage range up to 690V (supplier-listed)
  • Bolted terminal posts for cable or busbar connection

Available Models / Configurations

Use these RITOKS configuration references for enquiry; confirm the exact specification before ordering.

RITOKS referenceRated currentPolesWidth × height (mm)
RTX-HGL-125/3125A3P140 × 135
RTX-HGL-125/4125A4P170 × 135
RTX-HGL-160/3160A3P140 × 135
RTX-HGL-160/4160A4P170 × 135
RTX-HGL-200/3200A3P180 × 170
RTX-HGL-200/4200A4P230 × 170
RTX-HGL-250/3250A3P180 × 170
RTX-HGL-250/4250A4P230 × 170
RTX-HGL-315/3315A3P230 × 240
RTX-HGL-315/4315A4P290 × 240
RTX-HGL-400/3400A3P230 × 240
RTX-HGL-400/4400A4P290 × 240
RTX-HGL-500/3500A3P230 × 280
RTX-HGL-500/4500A4P290 × 280
RTX-HGL-630/3630A3P230 × 280
RTX-HGL-630/4630A4P290 × 280

Technical Specifications

Product typeLoad isolator switch, open type for panel mounting
Rated current range125A to 630A in eight frame sizes
Rated voltage0–690V AC range (supplier-listed)
Poles3P or 4P
OperationFront-operated handle
Terminal connectionBolted terminal posts (supplier-listed)
Overall dimensions140 × 135 mm (125A 3P) to 290 × 280 mm (630A 4P), see model table
WeightApprox. 3.0 kg for 160A 3P (supplier-listed)
Utilisation category and operational current (AC-21/AC-22/AC-23)Confirm with RITOKS before ordering
Rated short-time withstand currentConfirm with RITOKS before ordering
Mechanical and electrical lifeConfirm with RITOKS before ordering
Padlocking and auxiliary contactsConfirm with RITOKS before ordering

Applications

AI-generated conceptual application context. Confirm equipment fit, installation conditions and circuit requirements for the selected configuration.

AI-generated scene of a technician next to a 3-pole panel-mounted load isolator switch with copper cable lugs inside a distribution cabinet

Incoming feeder isolation

Isolate the main incoming supply of low-voltage switchboards and sub-distribution panels before maintenance work.

Outgoing feeder sections

Provide a manual disconnect point for outgoing feeders to production lines, compressors, chillers and large pump sets.

Generator and transfer panels

Separate generator or alternative supplies in changeover and backup power panels where a visible break is required.

Information to Confirm for Selection

  • Rated current and number of poles (3P or 4P)
  • Load type and required utilisation category (AC-21, AC-22 or AC-23)
  • System voltage and prospective short-circuit current at the installation point
  • Cable or busbar size and termination method
  • Panel space available, using the width, height and hole spacing in the model table
  • Quantity and destination

FAQ

Can RTX-HGL switches break load current?

They are load isolator switches designed to make and break normal load current on infrequent operation. They are not short-circuit protection devices, so an upstream circuit breaker or fuses must protect the circuit. The exact utilisation category for each size should be confirmed before ordering.

When should I choose 4P instead of 3P?

Choose 4P when the neutral must be switched together with the phases, for example in some TN-S or generator changeover arrangements. Use 3P when the neutral is not switched.

How is RTX-HGL different from WOT and RTX-LBS?

WOT and RTX-LBS are rotary isolators for currents up to 125A, with RTX-LBS in an IP66 enclosure. RTX-HGL is an open panel-mounted switch for larger feeders from 125A to 630A.

Request a Quote

Send the exact model, required ratings, quantity and destination. We will confirm availability and documentation before quotation.