Zeptejte se hned
RITOKS analog signal splitter with green DIN-rail housing and 4–20mA, 24VDC label

Electrical Measurement & Monitoring · RTX-AIS12

RTX-AIS12 Analog Signal Splitters

One-input, two-output DIN-rail signal modules distribute an analog measurement to separate receiving devices. Select the input, both outputs and DC supply as an exact configuration.

1 → 2Signal channels

DIN lištaMontáž

4–20 mAAvailable signal option

25 mmŠířka pouzdra

Přehled produktů

One-input, two-output DIN-rail signal modules distribute an analog measurement to separate receiving devices. Select the input, both outputs and DC supply as an exact configuration. Select the input range, both output ranges and DC supply separately. Isolation-test voltage requires exact-configuration documentation.

Hlavní vlastnosti

  • Architecture: One analog input and two analog outputs
  • Signal options: Current or voltage; exact order code required
  • Supply options: 5 / 12 / 15 / 24 V DC by version
  • Accuracy options: 0.1 / 0.2 / 0.5 grades by version
  • Dimensions: 106.7 × 79 × 25 mm

Dostupné modely / konfigurace

Use these configuration references for enquiry; confirm the exact specification before ordering.

RITOKS configuration referenceKonfiguraceSelection notes
RTX-AIS12-I-ICurrent input / current outputsSpecify both output channels
RTX-AIS12-V-VVoltage input / voltage outputsSpecify ranges and supply

Technické parametry

ArchitekturaOne analog input and two analog outputs
Signal optionsCurrent or voltage; exact order code required
Supply options5 / 12 / 15 / 24 V DC by version
Accuracy options0.1 / 0.2 / 0.5 grades by version
Rozměry106.7 × 79 × 25 mm

Aplikace

AI-generated conceptual application context, not a photograph of an actual installation. Confirm equipment fit and circuit requirements for the selected configuration.

Process Measurement — AI conceptual application illustration

Process Measurement

Send a compatible transmitter signal to two independent receiving channels.

PLC and Display Integration

Match signal ranges for a controller and a local indicator.

Instrumentation Retrofit

Review grounding, loading and wiring before changing an existing loop.

Údaje, které je třeba ověřit pro výběr

  • Input range, two output ranges and supply voltage
  • Receiving-device input impedance and loop wiring
  • Accuracy grade
  • Grounding and required isolation documentation

Často kladené otázky

What information is needed for a quotation?

Input range, two output ranges and supply voltage Please include quantity and destination.

What should be confirmed before selecting a configuration?

Select the input range, both output ranges and DC supply separately. Isolation-test voltage requires exact-configuration documentation.

Požádejte o cenovou nabídku

Uveďte přesný model, požadované parametry, množství a místo určení. Před vypracováním cenové nabídky ověříme dostupnost a dokumentaci.

Please include: Input range, two output ranges and supply voltage; Receiving-device input impedance and loop wiring; Accuracy grade.

Žádost o informace o produktu a cenách

Zašlete nám čísla modelů, výkonové parametry, počty kusů a údaje o místě určení. Před vypracováním cenové nabídky ověříme dostupnost zboží.

Přejít nahoru