RTX-PVN400 Square-Tube Blade gPV Fuses 200A-400A, 1500V DC

Square-tube gPV fuse links with blade contacts for PV combiner and inverter feeders, rated 200A to 400A at up to 1500V DC with 50kA breaking capacity.

Nominel strøm200A–400A

Nominel spændingDC1000V / DC1500V

Brudkapacitet50kA

KontaktoplysningerBlade (knife) type

Produktoversigt

RTX-PVN400 fuses protect high-current PV circuits such as combiner box outputs and inverter DC inputs, where the current exceeds the range of 10×85 cylindrical string fuses. The square-tube body with blade contacts fits matching fuse bases. Ratings of 200A, 250A, 315A, 350A and 400A are listed by the supplier, at DC1000V or DC1500V, with a maximum breaking current of 50kA. For PV string protection at lower currents, RITOKS supplies the MGPV cylindrical fuse links. Fuse base size and time-current characteristics must be confirmed for the selected rating.

Vigtigste funktioner

  • Rated currents 200A, 250A, 315A, 350A and 400A
  • DC1000V and DC1500V versions
  • 50kA maximum breaking current
  • Square-tube body with blade contacts for fuse-base mounting

Tilgængelige modeller / konfigurationer

Use these RITOKS configuration references for enquiry; confirm the exact specification before ordering.

RITOKS-referenceNominel strømNominel spændingBrudkapacitet
RTX-PVN400-200200ADC1000V / DC1500V50kA
RTX-PVN400-250250ADC1000V / DC1500V50kA
RTX-PVN400-315315ADC1000V / DC1500V50kA
RTX-PVN400-350350ADC1000V / DC1500V50kA
RTX-PVN400-400400ADC1000V / DC1500V50kA

Tekniske specifikationer

ProdukttypegPV fuse link, square tube with blade contacts
Nominel strøm200A–400A
Nominel spændingDC1000V / DC1500V
Maximum breaking current50kA
VægtApprox. 500 g (supplier-listed)
Fuse base sizeConfirm with RITOKS before ordering
Power loss and I²t valuesConfirm with RITOKS before ordering
CertificeringConfirm with RITOKS before ordering

Anvendelser

AI-generated conceptual application context. Confirm equipment fit, installation conditions and circuit requirements for the selected configuration.

AI-generated scene of square-tube gPV fuses mounted in a large PV combiner box at a solar plant

PV combiner box outputs

Protect the main output of a combiner box that collects many strings before the inverter.

Central inverter DC inputs

Protect each DC input feeder of a central inverter in utility-scale PV plants.

PV-plus-storage DC buses

Provide high-current overcurrent protection on DC feeders shared by PV arrays and battery systems.

Oplysninger, der skal bekræftes i forbindelse med udvælgelsen

  • System DC voltage: 1000V or 1500V
  • Continuous current and required fuse rating
  • Matching fuse base or holder size
  • Ambient temperature, enclosure conditions and quantity

Ofte stillede spørgsmål

When should I choose RTX-PVN400 instead of MGPV fuse links?

MGPV cylindrical fuse links cover PV string protection at lower currents. RTX-PVN400 covers 200A to 400A feeders such as combiner outputs and inverter inputs.

Do you supply the fuse base?

Fuse bases depend on the body size of the selected rating. Ask RITOKS for a matching base with your fuse order.