Solar PV Fuses · RTX-PVN400
RTX-PVN400 Square-Tube Blade gPV Fuses 200A-400A, 1500V DC
Square-tube gPV fuse links with blade contacts for PV combiner and inverter feeders, rated 200A to 400A at up to 1500V DC with 50kA breaking capacity.
定格電流200A–400A
定格電圧DC1000V / DC1500V
破断強度50kA
連絡先Blade (knife) type
製品概要
RTX-PVN400 fuses protect high-current PV circuits such as combiner box outputs and inverter DC inputs, where the current exceeds the range of 10×85 cylindrical string fuses. The square-tube body with blade contacts fits matching fuse bases. Ratings of 200A, 250A, 315A, 350A and 400A are listed by the supplier, at DC1000V or DC1500V, with a maximum breaking current of 50kA. For PV string protection at lower currents, RITOKS supplies the MGPV cylindrical fuse links. Fuse base size and time-current characteristics must be confirmed for the selected rating.
主な特長
- Rated currents 200A, 250A, 315A, 350A and 400A
- DC1000V and DC1500V versions
- 50kA maximum breaking current
- Square-tube body with blade contacts for fuse-base mounting
取り扱いモデル/構成
Use these RITOKS configuration references for enquiry; confirm the exact specification before ordering.
| RITOKS リファレンス | 定格電流 | 定格電圧 | 破断強度 |
|---|---|---|---|
| RTX-PVN400-200 | 200A | DC1000V / DC1500V | 50kA |
| RTX-PVN400-250 | 250A | DC1000V / DC1500V | 50kA |
| RTX-PVN400-315 | 315A | DC1000V / DC1500V | 50kA |
| RTX-PVN400-350 | 350A | DC1000V / DC1500V | 50kA |
| RTX-PVN400-400 | 400A | DC1000V / DC1500V | 50kA |
技術仕様
| 製品タイプ | gPV fuse link, square tube with blade contacts |
|---|---|
| 定格電流 | 200A–400A |
| 定格電圧 | DC1000V / DC1500V |
| Maximum breaking current | 50kA |
| 重量 | Approx. 500 g (supplier-listed) |
| Fuse base size | Confirm with RITOKS before ordering |
| Power loss and I²t values | Confirm with RITOKS before ordering |
| 認証 | Confirm with RITOKS before ordering |
用途
AI-generated conceptual application context. Confirm equipment fit, installation conditions and circuit requirements for the selected configuration.

PV combiner box outputs
Protect the main output of a combiner box that collects many strings before the inverter.
Central inverter DC inputs
Protect each DC input feeder of a central inverter in utility-scale PV plants.
PV-plus-storage DC buses
Provide high-current overcurrent protection on DC feeders shared by PV arrays and battery systems.
選考の際に確認すべき情報
- System DC voltage: 1000V or 1500V
- Continuous current and required fuse rating
- Matching fuse base or holder size
- Ambient temperature, enclosure conditions and quantity
よくある質問
When should I choose RTX-PVN400 instead of MGPV fuse links?
MGPV cylindrical fuse links cover PV string protection at lower currents. RTX-PVN400 covers 200A to 400A feeders such as combiner outputs and inverter inputs.
Do you supply the fuse base?
Fuse bases depend on the body size of the selected rating. Ask RITOKS for a matching base with your fuse order.
お見積りのお申し込み
正確な型番、必要な定格、数量、および配送先をお知らせください。お見積り前に、在庫状況と必要書類について確認させていただきます。.