Electrical Measurement & Monitoring · RTX-RTT311
RTX-RTT311 DIN-Rail Temperature Transmitters
A single-input, single-output DIN-rail transmitter for RTD or thermocouple signals. The RTX-RTT311 reference covers the self-powered 4–20 mA configuration; Pt1000 is a custom option and must be confirmed.
EingabePt100 / Cu50 / Cu100 RTD; thermocouple options
Ausgabe4–20 mA self-powered; other codes by configuration
GenauigkeitRTD: ±0.1 °C below 100 °C or ±0.1% FS above
Lieferung18–32 VDC for self-powered version
Produktübersicht
A single-input, single-output DIN-rail transmitter for RTD or thermocouple signals. The RTX-RTT311 reference covers the self-powered 4–20 mA configuration; Pt1000 is a custom option and must be confirmed.
Wichtigste Merkmale
- PC-configurable input type and range
- Supports 2, 3 and 4-wire RTD connections
- Input, output and supply isolation
- DIN rail installation with PWR and ALM indication
Verfügbare Modelle / Konfigurationen
Use these RITOKS configuration references for enquiry; confirm the exact specification before ordering.
| RTX-RTT311 | 1 input / 1 output / 4–20 mA self-powered |
|---|---|
| RTX-RTT311-V | 1 input / 1 output / 0–10 V |
| RTX-RTT311-LP | 1 input / 1 output / 4–20 mA loop-powered |
Technische Daten
| Eingabe | Pt100 / Cu50 / Cu100 RTD; thermocouple options |
|---|---|
| Ausgabe | 4–20 mA self-powered; other codes by configuration |
| Genauigkeit | RTD: ±0.1 °C below 100 °C or ±0.1% FS above |
| Lieferung | 18–32 VDC for self-powered version |
| Isolation | Input, output and supply galvanically isolated |
| Response | ≤0.5 s |
| Montage | 35 mm standard DIN rail |
| Abmessungen | 12.7 × 110 × 118.9 mm (T × H × D) |
Anwendungen
AI-generated conceptual application context. Confirm equipment fit, installation conditions and circuit requirements for the selected configuration.

Schaltschränke
Convert RTD signals to a compatible analog control input.
Process skids
Use programmable ranges for verified temperature sensors.
Heating equipment
Confirm sensor wiring, range and output loop before commissioning.
Für die Auswahl zu bestätigende Informationen
- Sensor type and 2/3/4-wire connection
- Temperature range and output code
- Self-powered or loop-powered architecture
- Break detection, load and ambient conditions
Häufig gestellte Fragen
What information is needed for a quotation?
Please include the exact configuration reference, quantity, destination and documentation requirements.
Angebot anfordern
Bitte teilen Sie uns das genaue Modell, die erforderlichen Nennleistungen, die Menge und den Bestimmungsort mit. Wir werden vor der Angebotserstellung die Verfügbarkeit und die erforderlichen Unterlagen prüfen.