Jetzt anfragen
RITOKS RTX-RTT311 DIN rail temperature transmitter

Electrical Measurement & Monitoring · RTX-RTT311

RTX-RTT311 DIN-Rail Temperature Transmitters

A single-input, single-output DIN-rail transmitter for RTD or thermocouple signals. The RTX-RTT311 reference covers the self-powered 4–20 mA configuration; Pt1000 is a custom option and must be confirmed.

EingabePt100 / Cu50 / Cu100 RTD; thermocouple options

Ausgabe4–20 mA self-powered; other codes by configuration

GenauigkeitRTD: ±0.1 °C below 100 °C or ±0.1% FS above

Lieferung18–32 VDC for self-powered version

Produktübersicht

A single-input, single-output DIN-rail transmitter for RTD or thermocouple signals. The RTX-RTT311 reference covers the self-powered 4–20 mA configuration; Pt1000 is a custom option and must be confirmed.

Wichtigste Merkmale

  • PC-configurable input type and range
  • Supports 2, 3 and 4-wire RTD connections
  • Input, output and supply isolation
  • DIN rail installation with PWR and ALM indication

Verfügbare Modelle / Konfigurationen

Use these RITOKS configuration references for enquiry; confirm the exact specification before ordering.

RTX-RTT3111 input / 1 output / 4–20 mA self-powered
RTX-RTT311-V1 input / 1 output / 0–10 V
RTX-RTT311-LP1 input / 1 output / 4–20 mA loop-powered

Technische Daten

EingabePt100 / Cu50 / Cu100 RTD; thermocouple options
Ausgabe4–20 mA self-powered; other codes by configuration
GenauigkeitRTD: ±0.1 °C below 100 °C or ±0.1% FS above
Lieferung18–32 VDC for self-powered version
IsolationInput, output and supply galvanically isolated
Response≤0.5 s
Montage35 mm standard DIN rail
Abmessungen12.7 × 110 × 118.9 mm (T × H × D)

Anwendungen

AI-generated conceptual application context. Confirm equipment fit, installation conditions and circuit requirements for the selected configuration.

AI-generated conceptual application scene: DIN-rail temperature transmitter connected to RTD sensors in a process control cabinet

Schaltschränke

Convert RTD signals to a compatible analog control input.

Process skids

Use programmable ranges for verified temperature sensors.

Heating equipment

Confirm sensor wiring, range and output loop before commissioning.

Für die Auswahl zu bestätigende Informationen

  • Sensor type and 2/3/4-wire connection
  • Temperature range and output code
  • Self-powered or loop-powered architecture
  • Break detection, load and ambient conditions

Häufig gestellte Fragen

What information is needed for a quotation?

Please include the exact configuration reference, quantity, destination and documentation requirements.

Angebot anfordern

Bitte teilen Sie uns das genaue Modell, die erforderlichen Nennleistungen, die Menge und den Bestimmungsort mit. Wir werden vor der Angebotserstellung die Verfügbarkeit und die erforderlichen Unterlagen prüfen.

Produktinformationen und Preise anfordern

Bitte teilen Sie uns die Modellnummern, Nennleistungen, Mengen und Angaben zum Bestimmungsort mit. Wir prüfen die Verfügbarkeit, bevor wir Ihnen ein Angebot unterbreiten.

Zum Seitenanfang scrollen